1.
J Appl Clin Med Phys ; 25(1): e14229, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38032123

RESUMO

BACKGROUND: Pulsed reduced dose rate (PRDR) is an emerging radiotherapy technique for recurrent diseases. It is pertinent that the linac beam characteristics are evaluated for PRDR dose rates and a suitable dosimeter is employed for IMRT QA. PURPOSE: This study sought to investigate the pulse characteristics of a 6 MV photon beam during PRDR irradiations on a commercial linac. The feasibility of using EBT3 radiochromic film for use in IMRT QA was also investigated by comparing its response to a commercial diode array phantom. METHODS: A plastic scintillator detector was employed to measure the photon pulse characteristics across nominal repetition rates (NRRs) in the 5-600 MU/min range. Film was irradiated with dose rates in the 0.033-4 Gy/min range to study the dose rate dependence. Five clinical PRDR treatment plans were selected for IMRT QA with the Delta4 phantom and EBT3 film sheets. The planned and measured dose were compared using gamma analysis with a criterion of 3%/3 mm. EBT3 film QA was performed using a cumulative technique and a weighting factor technique. RESULTS: Negligible differences were observed in the pulse width and height data between the investigated NRRs. The pulse width was measured to be 3.15 ± 0.01 µ s $\mu s$ and the PRF was calculated to be 3-357 Hz for the 5-600 MU/min NRRs. The EBT3 film was found to be dose rate independent within 3%. The gamma pass rates (GPRs) were above 99% and 90% for the Delta4 phantom and the EBT3 film using the cumulative QA method, respectively. GPRs as low as 80% were noted for the weighting factor EBT3 QA method. CONCLUSIONS: Altering the NRRs changes the mean dose rate while the instantaneous dose rate remains constant. The EBT3 film was found to be suitable for PRDR dosimetry and IMRT QA with minimal dose rate dependence.


Assuntos
Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosimetria Fotográfica/métodos , Radiometria , Raios gama , Fótons
2.
Neurooncol Adv ; 6(1): vdae073, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38845694

RESUMO

Background: Patients with grade 2 glioma exhibit highly variable survival. Re-irradiation for recurrent disease has limited mature clinical data. We report treatment results of pulsed reduced-dose rate (PRDR) radiation for patients with recurrent grade 2 glioma. Methods: A retrospective analysis of 58 patients treated with PRDR from 2000 to 2021 was performed. Radiation was delivered in 0.2 Gy pulses every 3 minutes encompassing tumor plus margin. Survival outcomes and prognostic factors on outcome were Kaplan-Meier and Cox regression analyses. Results: The median survival from the date of initial surgery was 8.6 years (95% CI: 5.5-11.8 years). 69% of patients showed malignant transformation to grade 3 (38%) or grade 4 (31%) glioma. Overall survival following PRDR was 12.6 months (95% CI: 8.3-17.0 months) and progression-free survival was 6.2 months (95% CI: 3.8-8.6 months). Overall response rate based on post-PRDR MRI was 36%. In patients who maintained grade 2 histology at recurrence, overall survival from PRDR was 22.0 months with 5 patients remaining disease-free, the longest at 8.2 and 11.4 years. PRDR was generally well tolerated. Conclusions: To the best of our knowledge, this is the largest reported series of patients with recurrent grade 2 gliomas treated with PRDR radiation for disease recurrence. We demonstrate promising survival and acceptable toxicity profiles following re-irradiation. In the cohort of patients who maintain grade 2 disease, prolonged survival (>5 years) is observed in selected patients. For the entire cohort, 1p19q codeletion, KPS, and longer time from initial diagnosis to PRDR were associated with improved survival.

3.
Med Phys ; 39(8): 4788-94, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22894403

RESUMO

PURPOSE: A recent field safety notice from TomoTherapy detailed the underdosing of small, off-axis targets when receiving high doses per fraction. This is due to angular undersampling in the dose calculation gantry angles. This study evaluates a correction method to reduce the underdosing, to be implemented in the current version (v4.1) of the TomoTherapy treatment planning software. METHODS: The correction method, termed "Super Sampling" involved the tripling of the number of gantry angles from which the dose is calculated during optimization and dose calculation. Radiochromic film was used to measure the dose to small targets at various off-axis distances receiving a minimum of 21 Gy in one fraction. Measurements were also performed for single small targets at the center of the Lucy phantom, using radiochromic film and the dose magnifying glass (DMG). RESULTS: Without super sampling, the peak dose deficit increased from 0% to 18% for a 10 mm target and 0% to 30% for a 5 mm target as off-axis target distances increased from 0 to 16.5 cm. When super sampling was turned on, the dose deficit trend was removed and all peak doses were within 5% of the planned dose. For measurements in the Lucy phantom at 9.7 cm off-axis, the positional and dose magnitude accuracy using super sampling was verified using radiochromic film and the DMG. CONCLUSIONS: A correction method implemented in the TomoTherapy treatment planning system which triples the angular sampling of the gantry angles used during optimization and dose calculation removes the underdosing for targets as small as 5 mm diameter, up to 16.5 cm off-axis receiving up to 21 Gy.


Assuntos
Radiometria/métodos , Radiocirurgia/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia/métodos , Algoritmos , Dosimetria Fotográfica/métodos , Vidro , Humanos , Imagens de Fantasmas , Dosagem Radioterapêutica , Reprodutibilidade dos Testes , Software
4.
Med Phys ; 38(7): 4081-5, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21859007

RESUMO

PURPOSE: Small field dosimetry is prone to uncertainties due to the lack of electronic equilibrium and the use of the correct detector size relative to the field size measured. It also exhibits higher sensitivity to setup errors as well as large variation in output with field size and shape. Radiochromic film is an attractive method for reference dosimetry in small fields due to its ability to provide 2D dose measurements while having minimal impact on the dose distribution. Gafchromic EBT2 has a dose range of up to 40 Gy; therefore, it could potentially be useful for high dose reference dosimetry with high spatial resolution. This is a requirement in stereotactic radiosurgery deliveries, which deliver high doses per fraction to small targets. METHODS: Targets of 4 mm and 12 mm diameters were treated to a minimum peripheral dose of 21 Gy prescribed to 80% of the maximum dose in one fraction. Target doses were measured with EBT2 film (both targets) and an ion chamber (12 mm target only). Measured doses were compared with planned dose distributions using profiles through the target and minimum peripheral dose coverage. RESULTS: The measured target doses and isodose coverage agreed with the planned dose within +/-1 standard deviation of three measurements, which were 2.13% and 2.5% for the 4 mm and 12 mm targets, respectively. CONCLUSIONS: EBT2 film is a feasible dosimeter for high dose per fraction reference 2D dosimetry.


Assuntos
Dosimetria Fotográfica/instrumentação , Filme para Raios X , Fracionamento da Dose de Radiação , Relação Dose-Resposta à Radiação , Desenho de Equipamento , Análise de Falha de Equipamento , Doses de Radiação , Reprodutibilidade dos Testes , Sensibilidade e Especificidade