Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 111
Filtrar
1.
BMC Pediatr ; 23(1): 82, 2023 02 17.
Artigo em Inglês | MEDLINE | ID: mdl-36800953

RESUMO

BACKGROUND: Constantly elevated intra-abdominal pressure (IAH) can lead to abdominal compartment syndrome (ACS), which is associated with organ dysfunction and even multiorgan failure. Our 2010 survey revealed an inconsistent acceptance of definitions and guidelines among pediatric intensivists regarding the diagnosis and treatment of IAH and ACS in Germany. This is the first survey to assess the impact of the updated guidelines on neonatal/pediatric intensive care units (NICU/PICU) in German-speaking countries after WSACS published those in 2013. METHODS: We conducted a follow-up survey and sent 473 questionnaires to all 328 German-speaking pediatric hospitals. We compared our findings regarding awareness, diagnostics and therapy of IAH and ACS with the results of our 2010 survey. RESULTS: The response rate was 48% (n = 156). The majority of respondents was from Germany (86%) and working in PICUs with mostly neonatal patients (53%). The number of participants who stated that IAH and ACS play a role in their clinical practice rose from 44% in 2010 to 56% in 2016. Similar to the 2010 investigations, only a few neonatal/pediatric intensivists knew the correct WSACS definition of an IAH (4% vs 6%). Different from the previous study, the number of participants who correctly defined an ACS increased from 18 to 58% (p < 0,001). The number of respondents measuring intra-abdominal pressure (IAP) increased from 20 to 43% (p < 0,001). Decompressive laparotomies (DLs) were performed more frequently than in 2010 (36% vs. 19%, p < 0,001), and the reported survival rate was higher when a DL was used (85% ± 17% vs. 40 ± 34%). CONCLUSIONS: Our follow-up survey of neonatal/pediatric intensivists showed an improvement in the awareness and knowledge of valid definitions of ACS. Moreover, there has been an increase in the number of physicians measuring IAP in patients. However, a significant number has still never diagnosed IAH/ACS, and more than half of the respondents have never measured IAP. This reinforces the suspicion that IAH and ACS are only slowly coming into the focus of neonatal/pediatric intensivists in German-speaking pediatric hospitals. The goal should be to raise awareness of IAH and ACS through education and training and to establish diagnostic algorithms, especially for pediatric patients. The increased survival rate after conducting a prompt DL consolidates the impression that the probability of survival can be increased by timely surgical decompression in the case of full-blown ACS.


Assuntos
Síndromes Compartimentais , Hipertensão Intra-Abdominal , Recém-Nascido , Humanos , Criança , Hipertensão Intra-Abdominal/diagnóstico , Hipertensão Intra-Abdominal/etiologia , Hipertensão Intra-Abdominal/terapia , Unidades de Terapia Intensiva Neonatal , Seguimentos , Inquéritos e Questionários , Unidades de Terapia Intensiva Pediátrica , Síndromes Compartimentais/diagnóstico , Síndromes Compartimentais/terapia , Unidades de Terapia Intensiva
2.
J Cardiovasc Magn Reson ; 24(1): 46, 2022 08 04.
Artigo em Inglês | MEDLINE | ID: mdl-35922806

RESUMO

BACKGROUND: Maladaptive remodelling mechanisms occur in patients with repaired tetralogy of Fallot (rToF) resulting in a cycle of metabolic and structural changes. Biventricular shape analysis may indicate mechanisms associated with adverse events independent of pulmonary regurgitant volume index (PRVI). We aimed to determine novel remodelling patterns associated with adverse events in patients with rToF using shape and function analysis. METHODS: Biventricular shape and function were studied in 192 patients with rToF (median time from TOF repair to baseline evaluation 13.5 years). Linear discriminant analysis (LDA) and principal component analysis (PCA) were used to identify shape differences between patients with and without adverse events. Adverse events included death, arrhythmias, and cardiac arrest with median follow-up of 10 years. RESULTS: LDA and PCA showed that shape characteristics pertaining to adverse events included a more circular left ventricle (LV) (decreased eccentricity), dilated (increased sphericity) LV base, increased right ventricular (RV) apical sphericity, and decreased RV basal sphericity. Multivariate LDA showed that the optimal discriminative model included only RV apical ejection fraction and one PCA mode associated with a more circular and dilated LV base (AUC = 0.77). PRVI did not add value, and shape changes associated with increased PRVI were not predictive of adverse outcomes. CONCLUSION: Pathological remodelling patterns in patients with rToF are significantly associated with adverse events, independent of PRVI. Mechanisms related to incident events include LV basal dilation with a reduced RV apical ejection fraction.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Insuficiência da Valva Pulmonar , Tetralogia de Fallot , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Humanos , Valor Preditivo dos Testes , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Pulmonar/cirurgia , Tetralogia de Fallot/complicações , Tetralogia de Fallot/diagnóstico por imagem , Tetralogia de Fallot/cirurgia , Função Ventricular Direita
3.
Pediatr Cardiol ; 43(7): 1502-1516, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35394150

RESUMO

Subclinical alterations in left ventricular structure and function are detectable in adolescents with hypertension or obesity. However, data on early echocardiographic abnormalities in seemingly healthy children are lacking. Sex differences in cardiac structure and function have been previously reported, but sex-specific reference values are not available. Specifically, the potential interaction of sex and overweight has not been addressed at all. Anthropometric data, blood pressure and exercise tests were obtained in 356 healthy children. Echocardiographic parameters comprised peak early (E) and late (A) mitral inflow Doppler velocities, E/A ratio, tissue Doppler peak velocities of early (e') and late diastolic (a') excursion of mitral/septal annulus and isovolumetric relaxation time (IVRT). Left ventricular mass index (LVMI) and LVMI z-score were calculated. Interaction terms between BMI and sex and stratification by sex were used for analysis. We provide values for echocardiographic parameters for children of two age groups separated by BMI. Overweight/obese children had a significant higher LVMI, lower E/A ratio, higher E/e' ratios and a longer IVRT. For a given BMI in the upper ranges we demonstrated a higher LVMI in girls than in boys, the IVRT extended significantly more in girls than in boys with increasing BMI. There are sex differences in structural and functional echocardiographic parameters in children and adolescents. Our data not only confirms the importance of overweight and obesity, but demonstrates important interactions between sex and overweight. The greater susceptibility of overweight girls toward echocardiographic changes associated with potential long-term functional impairment needs further exploration and follow-up.Trial registration number DRKS00012371; Date 18.08.2017.


Assuntos
Obesidade Infantil , Disfunção Ventricular Esquerda , Adolescente , Criança , Diástole/fisiologia , Ecocardiografia , Feminino , Humanos , Masculino , Valva Mitral , Sobrepeso , Obesidade Infantil/complicações , Função Ventricular Esquerda
4.
Am J Physiol Heart Circ Physiol ; 320(2): H494-H510, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-33064563

RESUMO

Central blood pressure (cBP) is a highly prognostic cardiovascular (CV) risk factor whose accurate, invasive assessment is costly and carries risks to patients. We developed and assessed novel algorithms for estimating cBP from noninvasive aortic hemodynamic data and a peripheral blood pressure measurement. These algorithms were created using three blood flow models: the two- and three-element Windkessel (0-D) models and a one-dimensional (1-D) model of the thoracic aorta. We tested new and existing methods for estimating CV parameters (left ventricular ejection time, outflow BP, arterial resistance and compliance, pulse wave velocity, and characteristic impedance) required for the cBP algorithms, using virtual (simulated) subjects (n = 19,646) for which reference CV parameters were known exactly. We then tested the cBP algorithms using virtual subjects (n = 4,064), for which reference cBP were available free of measurement error, and clinical datasets containing invasive (n = 10) and noninvasive (n = 171) reference cBP waves across a wide range of CV conditions. The 1-D algorithm outperformed the 0-D algorithms when the aortic vascular geometry was available, achieving central systolic blood pressure (cSBP) errors ≤ 2.1 ± 9.7 mmHg and root-mean-square errors (RMSEs) ≤ 6.4 ± 2.8 mmHg against invasive reference cBP waves (n = 10). When the aortic geometry was unavailable, the three-element 0-D algorithm achieved cSBP errors ≤ 6.0 ± 4.7 mmHg and RMSEs ≤ 5.9 ± 2.4 mmHg against noninvasive reference cBP waves (n = 171), outperforming the two-element 0-D algorithm. All CV parameters were estimated with mean percentage errors ≤ 8.2%, except for the aortic characteristic impedance (≤13.4%), which affected the three-element 0-D algorithm's performance. The freely available algorithms developed in this work enable fast and accurate calculation of the cBP wave and CV parameters in datasets containing noninvasive ultrasound or magnetic resonance imaging data.NEW & NOTEWORTHY First, our proposed methods for CV parameter estimation and a comprehensive set of methods from the literature were tested using in silico and clinical datasets. Second, optimized algorithms for estimating cBP from aortic flow were developed and tested for a wide range of cBP morphologies, including catheter cBP data. Third, a dataset of simulated cBP waves was created using a three-element Windkessel model. Fourth, the Windkessel model dataset and optimized algorithms are freely available.


Assuntos
Aorta Torácica/fisiologia , Circulação Sanguínea , Pressão Sanguínea , Doenças Cardiovasculares/fisiopatologia , Modelos Cardiovasculares , Adolescente , Adulto , Algoritmos , Aorta Torácica/fisiopatologia , Criança , Feminino , Humanos , Masculino
5.
J Cardiovasc Magn Reson ; 23(1): 1, 2021 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-33390185

RESUMO

BACKGROUND: Pediatric patients are becoming increasingly referred for cardiovascular magnetic resonance (CMR). Measurement of ventricular wall thickness is typically part of the assessment and can be of diagnostic importance, e.g. in arterial hypertension. However, normal values for left ventricular (LV) and right ventricular (RV) wall thickness in pediatric patients are lacking. The aim of this study was to establish pediatric centile charts for segmental LV and RV myocardial thickness in a retrospective multicenter CMR study. METHODS: CMR was performed in 161 healthy children and adolescents with an age range between 6 and 18 years from two centers in the UK and Germany as well as from a previously published CMR project of the German Competence Network for Congenital Heart Defects. LV myocardial thickness of 16 segments was measured on the short axis stack using the American Heart Association segmentation model. In addition, the thickness of the RV inferior and anterior free wall as well as biventricular mass was measured. RESULTS: The mean age (standard deviation) of the subjects was 13.6 (2.9) years, 64 (39.7%) were female. Myocardial thickness of the basal septum (basal antero- and inferoseptal wall) was 5.2 (1.1) mm, and the basal lateral wall (basal antero- and inferolateral) measured 5.1 (1.2) mm. Mid-ventricular septum (antero- and inferoseptal wall) measured 5.5 (1.2) mm, and mid-ventricular lateral wall (antero- and inferolateral wall) was 4.7 (1.2) mm. Separate centile charts for boys and girls for all myocardial segments and myocardial mass were created because gender was significantly correlated with LV myocardial thickness (p < 0.001 at basal level, p = 0.001 at midventricular level and p = 0.005 at the apex) and biventricular mass (LV, p < 0.001; RV, p < 0.001). CONCLUSION: We established CMR normal values of segmental myocardial thickness and biventricular mass in children and adolescents. Our data are of use for the detection of abnormal myocardial properties and can serve as a reference in future studies and clinical practice.


Assuntos
Ventrículos do Coração/diagnóstico por imagem , Imagem Cinética por Ressonância Magnética , Adolescente , Fatores Etários , Criança , Feminino , Alemanha , Humanos , Masculino , Valor Preditivo dos Testes , Valores de Referência , Estudos Retrospectivos , Reino Unido , Função Ventricular Esquerda , Função Ventricular Direita , Remodelação Ventricular
6.
BMC Med Inform Decis Mak ; 21(1): 62, 2021 02 18.
Artigo em Inglês | MEDLINE | ID: mdl-33602206

RESUMO

BACKGROUND: Systemic inflammatory response syndrome (SIRS) is defined as a non-specific inflammatory process in the absence of infection. SIRS increases susceptibility for organ dysfunction, and frequently affects the clinical outcome of affected patients. We evaluated a knowledge-based, interoperable clinical decision-support system (CDSS) for SIRS detection on a pediatric intensive care unit (PICU). METHODS: The CDSS developed retrieves routine data, previously transformed into an interoperable format, by using model-based queries and guideline- and knowledge-based rules. We evaluated the CDSS in a prospective diagnostic study from 08/2018-03/2019. 168 patients from a pediatric intensive care unit of a tertiary university hospital, aged 0 to 18 years, were assessed for SIRS by the CDSS and by physicians during clinical routine. Sensitivity and specificity (when compared to the reference standard) with 95% Wald confidence intervals (CI) were estimated on the level of patients and patient-days. RESULTS: Sensitivity and specificity was 91.7% (95% CI 85.5-95.4%) and 54.1% (95% CI 45.4-62.5%) on patient level, and 97.5% (95% CI 95.1-98.7%) and 91.5% (95% CI 89.3-93.3%) on the level of patient-days. Physicians' SIRS recognition during clinical routine was considerably less accurate (sensitivity of 62.0% (95% CI 56.8-66.9%)/specificity of 83.3% (95% CI 80.4-85.9%)) when measurd on the level of patient-days. Evaluation revealed valuable insights for the general design of the CDSS as well as specific rule modifications. Despite a lower than expected specificity, diagnostic accuracy was higher than the one in daily routine ratings, thus, demonstrating high potentials of using our CDSS to help to detect SIRS in clinical routine. CONCLUSIONS: We successfully evaluated an interoperable CDSS for SIRS detection in PICU. Our study demonstrated the general feasibility and potentials of the implemented algorithms but also some limitations. In the next step, the CDSS will be optimized to overcome these limitations and will be evaluated in a multi-center study. TRIAL REGISTRATION: NCT03661450 (ClinicalTrials.gov); registered September 7, 2018.


Assuntos
Estado Terminal , Sistemas de Apoio a Decisões Clínicas , Adolescente , Criança , Pré-Escolar , Humanos , Lactente , Recém-Nascido , Unidades de Terapia Intensiva Pediátrica , Estudos Prospectivos , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico
7.
J Card Surg ; 36(12): 4551-4557, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34595768

RESUMO

BACKGROUND: Despite considerable progress in heart transplantation, pediatric waiting list mortality is still high, and often patients do not have enough time to wait. We hypothesized that extending the donor criteria regarding age and weight mismatch does not significantly affect the early follow-up. METHODS: We retrospectively analyzed our pediatric heart transplantation patients operated on from 2014 to 2020 for high (>3.0) or low (<0.6) donor-recipient weight ratio (DRWR) or chronological age mismatches (donor organ >5 years older than recipient age). This patient cohort constituted "mismatched heart transplantations" (mHTX). We compared mHTX preoperative status, postoperative course, 1-year survival, and early clinical follow-up to standard pediatric heart transplantations (sHTX). RESULTS: We performed 20 pediatric heart transplantations-10 mHTX and 10 sHTX. The minimum DRWR was 0.44, the maximum was 5.60, and the maximum age mismatch was 42.6 years. Median days in the intensive care unit (p = .436) and time-to-first-rejection episode (p = .925) were comparable. Nine patients in each group were alive after 1 year, two patients were operated within 1 year of follow-up. One mHTX patient developed cardiac allograft vasculopathy after 15 months and died 648 days after transplantation (p = .237). All other patients were alive at the end of follow-up and in good clinical conditions (median follow-up for mHTX was 732.5 days, 1149.5 days for sHTX). CONCLUSION: Postoperative course and early follow-up after mHTX were comparable to sHTX. In urgent clinical situations, extended donor criteria may be considered an additional option for pediatric heart transplantation.


Assuntos
Transplante de Coração , Listas de Espera , Adulto , Criança , Pré-Escolar , Estudos de Coortes , Humanos , Estudos Retrospectivos , Doadores de Tecidos
8.
J Biol Phys ; 47(2): 171-190, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34036473

RESUMO

Non-invasive estimation of the pressure gradient in cardiovascular stenosis has much clinical importance in assisting the diagnosis and treatment of stenotic diseases. In this research, a systematic comparison is conducted to investigate the accuracy of a group of stenosis models against the MRI- and catheter-measured patient data under the aortic coarctation condition. Eight analytical stenosis models, including six from the literature and two proposed in this study, are investigated to examine their prediction accuracy against the clinical data. The two improved models proposed in this study consider comprehensively the Poiseuille loss, the Bernoulli loss in its exact form, and the entrance effect, of the blood flow. Comparison of the results shows that one of the proposed models demonstrates a cycle-averaged mean prediction error of -0.15 ± 3.03 mmHg, a peak-to-peak prediction error of -1.8 ± 6.89 mmHg, which is the best among the models studied.


Assuntos
Coartação Aórtica , Coartação Aórtica/diagnóstico , Constrição Patológica , Hemodinâmica , Humanos
9.
BMC Med Imaging ; 20(1): 113, 2020 10 08.
Artigo em Inglês | MEDLINE | ID: mdl-33032536

RESUMO

BACKGROUND: Deep learning algorithms are increasingly used for automatic medical imaging analysis and cardiac chamber segmentation. Especially in congenital heart disease, obtaining a sufficient number of training images and data anonymity issues remain of concern. METHODS: Progressive generative adversarial networks (PG-GAN) were trained on cardiac magnetic resonance imaging (MRI) frames from a nationwide prospective study to generate synthetic MRI frames. These synthetic frames were subsequently used to train segmentation networks (U-Net) and the quality of the synthetic training images, as well as the performance of the segmentation network was compared to U-Net-based solutions trained entirely on patient data. RESULTS: Cardiac MRI data from 303 patients with Tetralogy of Fallot were used for PG-GAN training. Using this model, we generated 100,000 synthetic images with a resolution of 256 × 256 pixels in 4-chamber and 2-chamber views. All synthetic samples were classified as anatomically plausible by human observers. The segmentation performance of the U-Net trained on data from 42 separate patients was statistically significantly better compared to the PG-GAN based training in an external dataset of 50 patients, however, the actual difference in segmentation quality was negligible (< 1% in absolute terms for all models). CONCLUSION: We demonstrate the utility of PG-GANs for generating large amounts of realistically looking cardiac MRI images even in rare cardiac conditions. The generated images are not subject to data anonymity and privacy concerns and can be shared freely between institutions. Training supervised deep learning segmentation networks on this synthetic data yielded similar results compared to direct training on original patient data.


Assuntos
Imagem Cinética por Ressonância Magnética/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tetralogia de Fallot/diagnóstico por imagem , Adolescente , Algoritmos , Aprendizado Profundo , Feminino , Humanos , Masculino , Estudos Prospectivos , Aprendizado de Máquina Supervisionado , Adulto Jovem
10.
Cardiol Young ; 29(7): 972-976, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31218985

RESUMO

AIMS: Transcatheter implantation of pulmonary balloon-expandable stent-valves requires pre-stenting of the right ventricular outflow tract with large calibre stents. To increase awareness of the associated risks of this part of transcatheter pulmonary valve replacement therapy, we report potential fatal complications during the implantation of AndraStents® in the right ventricular outflow tract in six cases from five different European institutions and their management. METHOD AND RESULT: We present a retrospective case series analysis looking at the time period from 2013 to 2018. Of 127 AndraStents® implanted in the right ventricular outflow tract, in six patients, age from 13 to 71 years, a misconfiguration of the AndraStent® occurred forming a "diabolo"-configuration. During inflation of the balloon, the stent showed extreme "dog-boning", an expansion of the stent at both ends with the middle part remaining unexpanded. This led to rupture of the balloon and loss of manoeuvrability in four patients. Out of the total six cases, in four patients the stent was eventually expanded with high-pressure balloons, and in one case the stent was surgically retrieved. In one patient, in whom a percutaneous retrieval of the embolised stent was attempted, a fatal bleeding occurred. CONCLUSIONS: Pre-stenting of the right ventricular outflow tract by AndraStents® can lead to misconfiguration of the stent with potentially fatal complications. Rescue strategies of misconfigured stents include stent inflation and placement with high pressure non-compliant balloons or surgical backup. Interventional retrieval measures of AndraStents® cannot be advised.


Assuntos
Angioplastia Coronária com Balão/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Falha de Prótese/etiologia , Valva Pulmonar , Stents/efeitos adversos , Obstrução do Fluxo Ventricular Externo/cirurgia , Adolescente , Adulto , Idoso , Angioplastia Coronária com Balão/instrumentação , Cateterismo Cardíaco/efeitos adversos , Feminino , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Estudos Retrospectivos , Adulto Jovem
11.
Liver Transpl ; 24(6): 820-830, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29637720

RESUMO

In adults, cirrhotic cardiomyopathy (CCM) has a significant incidence and impact on liver transplantation. For pediatric liver transplantation (pLT), data on liver-induced cardiac changes are scarce, and in particular, the comparison between cirrhotic and noncirrhotic liver disease has not been investigated. We retrospectively evaluated cardiac changes associated with CCM by echocardiography and 12-lead electrocardiogram in 198 pLT-candidates (median age 4.1 years) 4.2 before and 12 months after pLT. Results were correlated with the stage of liver fibrosis and cholestasis before transplantation. The left ventricular end-diastolic diameter (LVIDd) z score, left ventricular mass z score, and left ventricular mass index were significantly higher in cirrhotic patients (-0.10 versus 0.98, P < 0.001; -1.55 versus -0.42, P = 0.001; 78.99 versus 125.64 g/m2 , P = 0.001, respectively) compared with children with noncirrhotic liver disease. Pathological z scores (>2SDS) for the LVIDd occurred more frequently in cirrhotic patients compared with patients with noncirrhotic liver disease (31/169 versus 1/29; P = 0.03) and were significantly associated with cholestasis. All observed cardiac changes were reversible 1 year after pLT. Pathological LVIDd z scores correlated highly with intensive care unit (ICU) stay (9.6 days versus 17.1 days, respectively, P = 0.002) but not with patient survival pre-LT or post-LT. In contrast to other studies, prolonged QTc time was not associated with liver cirrhosis in our patients. In conclusion, CCM-associated cardiac changes in pLT candidates with cirrhotic liver disease are frequent, mild, and associated with cholestasis and reversible after pLT. They may impact peritransplant care and posttransplant hospitalization time. Further prospective evaluation is warranted. In particular, for QTc time prolongation etiological factors, possible protective effects of ursodeoxycholic acid treatment and the use as a screening parameter for CCM should be verified. Liver Transplantation 24 820-830 2018 AASLD.


Assuntos
Cardiomiopatias/epidemiologia , Colestase/complicações , Doença Hepática Terminal/cirurgia , Cirrose Hepática/cirurgia , Transplante de Fígado , Adolescente , Cardiomiopatias/diagnóstico , Cardiomiopatias/etiologia , Criança , Pré-Escolar , Colagogos e Coleréticos/uso terapêutico , Colestase/epidemiologia , Colestase/prevenção & controle , Ecocardiografia , Eletrocardiografia , Doença Hepática Terminal/complicações , Doença Hepática Terminal/mortalidade , Feminino , Humanos , Incidência , Lactente , Tempo de Internação/estatística & dados numéricos , Cirrose Hepática/complicações , Cirrose Hepática/mortalidade , Masculino , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento , Ácido Ursodesoxicólico/uso terapêutico
12.
Eur Radiol ; 28(3): 1257-1266, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28875228

RESUMO

PURPOSE: Left ventricular two-dimensional global longitudinal strain (LS) is superior to ejection fraction (EF) as predictor of outcome. We provide reference data for atrial and ventricular global LS during childhood and adolescence by CMR feature tracking (FT). METHODS: We prospectively enrolled 115 healthy subjects (56 male, mean age 12.4 ± 4.1 years) at a single institution. CMR consisted of standard two-dimensional steady-state free-precession acquisitions. CMR-FT was performed on ventricular horizontal long-axis images for derivation of right and left atrial (RA, LA) and right and left ventricular (RV, LV) peak global LS. End-diastolic volumes (EDVs) and EF were measured. Correlations were explored for LS with age, EDV and EF of each chamber. RESULTS: Mean±SD of LS (%) for RA, RV, LA and LV were 26.56±10.2, -17.96±5.4, 26.45±10.6 and -17.47±5, respectively. There was a positive correlation of LS in LA, LV, RA and RV with corresponding EF (all P<0.05); correlations with age were weak. Gender-wise differences were not significant for atrial and ventricular LS, strain rate and displacement. Inter- and intra-observer comparisons showed moderate agreements. CONCLUSIONS: Chamber-specific nomograms for paediatric atrial and ventricular LS are provided to serve as clinical reference, and to facilitate CMR-based deformation research. KEY POINTS: • No normative data exist for CMR-derived global longitudinal strain in the young. • This prospective study provides reference data for atrial and ventricular longitudinal strain. • The data will serve as reference for CMR-based clinical and research use.


Assuntos
Cardiopatias Congênitas/diagnóstico , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Miocárdio/patologia , Criança , Feminino , Voluntários Saudáveis , Cardiopatias Congênitas/fisiopatologia , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
13.
BMC Pediatr ; 18(1): 112, 2018 03 15.
Artigo em Inglês | MEDLINE | ID: mdl-29544449

RESUMO

BACKGROUND: Since early antimicrobial therapy is mandatory in septic patients, immediate diagnosis and distinction from non-infectious SIRS is essential but hampered by the similarity of symptoms between both entities. We aimed to develop a diagnostic model for differentiation of sepsis and non-infectious SIRS in critically ill children based on routinely available parameters (baseline characteristics, clinical/laboratory parameters, technical/medical support). METHODS: This is a secondary analysis of a randomized controlled trial conducted at a German tertiary-care pediatric intensive care unit (PICU). Two hundred thirty-eight cases of non-infectious SIRS and 58 cases of sepsis (as defined by IPSCC criteria) were included. We applied a Random Forest approach to identify the best set of predictors out of 44 variables measured at the day of onset of the disease. The developed diagnostic model was validated in a temporal split-sample approach. RESULTS: A model including four clinical (length of PICU stay until onset of non-infectious SIRS/sepsis, central line, core temperature, number of non-infectious SIRS/sepsis episodes prior to diagnosis) and four laboratory parameters (interleukin-6, platelet count, procalcitonin, CRP) was identified in the training dataset. Validation in the test dataset revealed an AUC of 0.78 (95% CI: 0.70-0.87). Our model was superior to previously proposed biomarkers such as CRP, interleukin-6, procalcitonin or a combination of CRP and procalcitonin (maximum AUC = 0.63; 95% CI: 0.52-0.74). When aiming at a complete identification of sepsis cases (100%; 95% CI: 87-100%), 28% (95% CI: 20-38%) of non-infectious SIRS cases were assorted correctly. CONCLUSIONS: Our approach allows early recognition of sepsis with an accuracy superior to previously described biomarkers, and could potentially reduce antibiotic use by 30% in non-infectious SIRS cases. External validation studies are necessary to confirm the generalizability of our approach across populations and treatment practices. TRIAL REGISTRATION: ClinicalTrials.gov number: NCT00209768; registration date: September 21, 2005.


Assuntos
Algoritmos , Técnicas de Apoio para a Decisão , Aprendizado de Máquina , Síndrome de Resposta Inflamatória Sistêmica/diagnóstico , Adolescente , Criança , Pré-Escolar , Estado Terminal , Diagnóstico Diferencial , Diagnóstico Precoce , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Sepse/diagnóstico
14.
Eur Radiol ; 27(1): 167-177, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27215582

RESUMO

OBJECTIVES: In patients with repaired coarctation of aorta (CoA), we assessed ventriculo-vascular characteristics using CMR-derived aortic area strain (AAS), left atrial (LA) and left ventricular (LV) longitudinal and circumferential strain (LS, CS). METHODS: Seventy-five subjects including 50 with repaired CoA divided into hypertensive (n = 25), normotensive (n = 25) and 25 controls were studied. AAS was measured at 3 levels: ascending aorta, proximal descending and descending aorta. LA and LV LS were measured using CMR-feature tracking. LA and LV end-diastolic volumes, ejection fraction (EF) and mass were measured. RESULTS: Mean patient age was 19.7 ± 6.7 and controls 23 ± 15 (years). All strains (LA, LV, ascending and descending aortic) were lower in CoA subgroups compared to controls except the AAS at diaphragm, which was not different. Comparisons between hypertensive and normotensive CoA showed no differences in LV mass, LV volumetric indices, and LA and LV strain indices; however, ascending AAS was lower in hypertensive subgroup (p = 0.02). Ascending AAS was correlated with LV mass (r = -0.4, p = 0.005), LVEF (r = -0.4, p = 0.004), systolic blood pressure (r = -0.5, p = 0.0001) and LVLS (r = 0.5, p = 0.001). CONCLUSIONS: Ascending AAS correlated with LV mass, EF and LVLS. In hypertensive CoA, ascending AAS was reduced compared to normotensive CoA and controls, indicating vascular remodelling differences influenced by ongoing hypertension. KEY POINTS: • Impaired arterial strain is a measure of increased stiffness in arteries • Ascending aorta strain correlates with left ventricular mass and longitudinal strain • Ascending aorta strain is significantly lower in hypertensive coarctation patients • Hypertension may be a consequence of vascular pathology persisting despite repair.


Assuntos
Aorta/diagnóstico por imagem , Coartação Aórtica/cirurgia , Átrios do Coração/fisiopatologia , Ventrículos do Coração/fisiopatologia , Imagem Cinética por Ressonância Magnética/métodos , Rigidez Vascular/fisiologia , Função Ventricular Esquerda/fisiologia , Adolescente , Aorta/fisiopatologia , Aorta/cirurgia , Coartação Aórtica/diagnóstico , Coartação Aórtica/fisiopatologia , Pressão Sanguínea , Criança , Feminino , Átrios do Coração/diagnóstico por imagem , Ventrículos do Coração/diagnóstico por imagem , Humanos , Masculino , Período Pós-Operatório , Procedimentos Cirúrgicos Vasculares , Adulto Jovem
15.
Pediatr Cardiol ; 38(1): 135-148, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27826705

RESUMO

Transpulmonary ultrasound dilution (TPUD) method, a novel indicator dilution (ID) technique for cardiac output measurement, detects and quantifies shunts, both in children and adults. However, its accuracy and reproducibility in cardiac right-to-left-shunt (RLS) detection have not been investigated. In a prospective observational study, we assessed the validity of TPUD algorithm for RLS detection in children with congenital heart disease (CHD) and proven RLS in comparison with controls without shunts between February 2010 and October 2011. As TPUD algorithm was unknown, we tested ID curve morphology, appearance time (AT) and central blood volume index (CBVI) as diagnostic criteria. TPUD identified RLS correctly in all 16 RLS subjects [median age (range): 18 months (1 month-15 years 6 months)] and excluded RLS in all 26 controls [74 months (8 months to 17 years 4 months)]. AT was significantly shorter in RLS (P < 0.05). Applying only AT (93.8 % sensitivity, 92.3 % specificity), RLS can be detected by shortening of ≥1.69 s of normally expected AT. RLS ID curves were subdivided into four morphological categories: (I) hump-on-upslope (n = 5); (II) double-hump (n = 3); (III) pseudonormal (n = 3); (IV) abnormal width (n = 5). No correlation was found between specific type of CHD and RLS categories. CBVI measurements were significantly smaller in RLS categories I-III than in controls (P < 0.05). TPUD appears to be a valid method for cardiac RLS detection. Shortened AT and low CBVI are reliable parameters for RLS identification. RLS categories have specific implications for cardiac output, blood volume and RLS fraction measurements. TPUD is valuable to monitor shunt direction and magnitude to optimise haemodynamic and respiratory therapy.


Assuntos
Cateterismo Cardíaco/métodos , Débito Cardíaco/fisiologia , Cardiopatias Congênitas/diagnóstico por imagem , Ultrassonografia/métodos , Adolescente , Algoritmos , Criança , Pré-Escolar , Estudos de Viabilidade , Feminino , Coração/diagnóstico por imagem , Coração/fisiopatologia , Cardiopatias Congênitas/fisiopatologia , Hemodinâmica/fisiologia , Humanos , Técnicas de Diluição do Indicador , Lactente , Pulmão/fisiopatologia , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
16.
J Card Surg ; 32(2): 116-125, 2017 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-27928843

RESUMO

BACKGROUND: Systemic inflammatory response syndrome (SIRS) is frequent after cardiac surgery, but data on its incidence and perioperative risk factors are scarce for children with congenital heart disease. METHODS: SIRS incidence within 72 hours following cardiac surgery was evaluated in a secondary analysis of children enrolled to a treatment-free control group of a randomized controlled trial. Intraoperative parameters were investigated for their association with SIRS using multivariable fractional polynomial logistic regression models. Effects of SIRS on various organ functions and length of stay were evaluated using time-varying Cox regression models. RESULTS: In 116 children after cardiac surgery (median age [range]: 7.4 month [1 day-16.2 years]) SIRS occurred in n = 39/102 with and n = 1/14 without cardiopulmonary bypass (CPB). Duration of CPB (hazard ratio [HR]: 2.28 per hour; 95% confidence interval [CI] 1.17; 4.42) and amount of fresh frozen plasma (HR: 1.23 per 10 mL/kg; 95%CI 1.06; 1.42) were identified as predictors for SIRS; neonates seemed to be less susceptible for SIRS development (HR: 0.86; 95%CI 0.79; 0.95). SIRS was associated with organ dysfunction (HR: 2.69; 95%CI 1.41; 5.12) and extended stay in the pediatric intensive care unit (PICU) (median: 168 vs. 96 hours; p = 0.007). CONCLUSIONS: SIRS is a frequent complication after pediatric congenital heart surgery; it affects nearly one third of children and prolongs PICU stay significantly. Duration of CPB and amount of fresh frozen plasma were identified as important risk factors. Neonates seem to be less susceptible to SIRS development.


Assuntos
Cardiopatias Congênitas/cirurgia , Unidades de Terapia Intensiva Pediátrica , Complicações Pós-Operatórias , Medição de Risco/métodos , Síndrome de Resposta Inflamatória Sistêmica/epidemiologia , Adolescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Ponte Cardiopulmonar/efeitos adversos , Criança , Pré-Escolar , Feminino , Seguimentos , Alemanha/epidemiologia , Humanos , Incidência , Lactente , Recém-Nascido , Masculino , Estudos Prospectivos , Fatores de Risco , Síndrome de Resposta Inflamatória Sistêmica/etiologia
17.
Thorac Cardiovasc Surg ; 64(1): 25-35, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26322831

RESUMO

BACKGROUND: Various diseases and diversity in implantation ages, together with evolving diagnostic and therapeutic options, hinder comparative evaluations of long-term outcomes for valved conduits used for reconstruction of the right ventricular outflow tract (RVOT). We combined two common evaluation methods to optimally use information obtained by pooling the raw data from two high volume centers, each with very regular follow-up procedures, with the aim of analyzing durability differences between conventional homografts and bovine jugular veins. PATIENTS AND METHODS: In the period 1985 to 2012, a total of 444 bovine jugular veins and 267 homografts were implanted, and 6,738 postoperative examinations took place. Evaluations included age-stratified Kaplan-Meier analyses, Cox regression models, and time status graphs, the third showing age-group stratified, time-related frequencies of intact, insufficient, stenotic, both insufficient and stenotic, and postinterventional conduits below the freedom from explantation curve. They take into account interventions, explantations, and the nonterminal character of echocardiographic findings. RESULTS: The durability of intact bovine jugular veins in children and young adults is not inferior to that of homografts. Averaged over the first 12 years after implantation, the age groups < 25 years in fact showed advantages for bovine jugular vein recipients. The average fraction of patients younger than 25 years whose conduits were not explanted, postinterventional, stenotic, insufficient, or stenotic and insufficient was at least 10% higher in recipients of bovine jugular veins than in homograft recipients. CONCLUSION: According to the time status graphs, the use of bovine jugular veins for RVOT in patients younger than 25 years appears to lead to superior results when compared with cryopreserved homografts.


Assuntos
Bioprótese , Implante de Prótese Vascular/instrumentação , Prótese Vascular , Implante de Prótese de Valva Cardíaca/instrumentação , Próteses Valvulares Cardíacas , Veias Jugulares/transplante , Artéria Pulmonar/transplante , Valva Pulmonar/transplante , Adolescente , Adulto , Fatores Etários , Aloenxertos , Animais , Implante de Prótese Vascular/efeitos adversos , Implante de Prótese Vascular/métodos , Implante de Prótese Vascular/mortalidade , Bovinos , Criança , Pré-Escolar , Remoção de Dispositivo , Feminino , Alemanha , Sobrevivência de Enxerto , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/mortalidade , Xenoenxertos , Hospitais com Alto Volume de Atendimentos , Humanos , Lactente , Recém-Nascido , Estimativa de Kaplan-Meier , Masculino , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Desenho de Prótese , Falha de Prótese , Reoperação , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Adulto Jovem
18.
Pediatr Cardiol ; 36(6): 1270-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25845941

RESUMO

Cardiac surgery with cardiopulmonary bypass (CPB) frequently leads to systemic inflammatory response syndrome (SIRS) with concomitant organ malfunction. Infused particles may exacerbate inflammatory syndromes since they activate the coagulation cascade and alter inflammatory response or microvascular perfusion. In a randomized, controlled, prospective trial, we have previously shown that particle-retentive in-line filtration prevented major complications in critically ill children. Now, we investigated the effect of in-line filtration on major complications in the subgroup of cardiac patients. Children admitted to tertiary pediatric intensive care unit were randomized to either control or filter group obtaining in-line filtration throughout complete infusion therapy. Risk differences and 95 % confidence intervals (CI) of several complications such as SIRS, sepsis, mortality, various organ failure and dysfunction were compared between both groups using the Wald method. 305 children (n = 150 control, n = 155 filter group) with cardiac diseases were finally analyzed. The majority was admitted after cardiac surgery with CPB. Risk of SIRS (-11.3 %; 95 % CI -21.8 to -0.5 %), renal (-10.0 %; 95 % CI -17.0 to -3.0 %) and hematologic (-8.1 %; 95 % CI -14.2 to -0.2 %) dysfunction were significantly decreased within the filter group. No risk differences were demonstrated for occurrence of sepsis, any other organ failure or dysfunctions between both groups. Infused particles might aggravate a systemic hypercoagulability and inflammation with subsequent organ malfunction in pediatric cardiac intensive care patients. Particle-retentive in-line filtration might be effective in preventing SIRS and maintaining renal and hematologic function. In-line filtration offers a novel therapeutic option to decrease morbidity in cardiac intensive care.


Assuntos
Ponte Cardiopulmonar/efeitos adversos , Cuidados Críticos/métodos , Contaminação de Medicamentos/prevenção & controle , Filtração/métodos , Infusões Intravenosas/métodos , Síndrome de Resposta Inflamatória Sistêmica/prevenção & controle , Adolescente , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Infusões Intravenosas/instrumentação , Unidades de Terapia Intensiva Pediátrica , Tempo de Internação/estatística & dados numéricos , Masculino , Insuficiência de Múltiplos Órgãos/prevenção & controle , Material Particulado/efeitos adversos , Estudos Prospectivos , Fatores de Risco , Sepse/prevenção & controle , Síndrome de Resposta Inflamatória Sistêmica/complicações , Síndrome de Resposta Inflamatória Sistêmica/etiologia , Síndrome de Resposta Inflamatória Sistêmica/mortalidade , Trombofilia/prevenção & controle , Resultado do Tratamento
19.
Magn Reson Med ; 72(1): 202-10, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23922308

RESUMO

PURPOSE: Thoracic pulse wave velocity (PWV) variation due to modulated trans-mural pressure (TMP) may indicate mechanical properties of the aorta. Our aim was to measure beat-to-beat thoracic PWV and TMP to observe its normal variation during respiratory maneuvers. METHODS: We validated PWV measurements from a real-time velocity projection MRI scan in a pulsatile phantom. A volunteer study showed inter-scan repeatability of steady-state PWV, and observed PWV variation when performing Mueller and Valsalva maneuvers. Synchronized to the real-time projection velocity data, TMP was measured using a mouth piece and pressure sensor arrangement monitoring the intra-thoracic pressure and a single arterial pressure measurement. RESULTS: In the phantom, beat-to-beat PWV derived from real-time projection (5.33 ± 0.32 m s(-1) ) agreed well with experimentally derived PWV using ultrasound probes (5.72 ± 0.50 m s(-1) ). The within-subject PWV variation between scans was 0.28 m s(-1) . Volunteers' PWVs increased during Mueller maneuver (TMP increase of 14.67 ± 10.69 mmHg) by 32% (P < 0.001), and during Valsalva maneuver (TMP decrease of TMP = 17.01 ± 12.91 mmHg), PWV response were inconsistent with an average increase of 14% (P < 0.05). CONCLUSION: Gating TMP to beat-to-beat PWV allows insight into how aortic stiffness varies with strain. However, quantifying nonlinear arterial stiffness requires real-time arterial pressure measurement.


Assuntos
Aorta Torácica/anatomia & histologia , Aorta Torácica/fisiologia , Imageamento por Ressonância Magnética/métodos , Manobra de Valsalva , Adulto , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Voluntários Saudáveis , Hemorreologia , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Fluxo Pulsátil , Fluxo Sanguíneo Regional
20.
Invest Radiol ; 59(6): 472-478, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38117123

RESUMO

BACKGROUND: Post-COVID syndrome (PCS) can adversely affect the quality of life of patients and their families. In particular, the degree of cardiac impairment in children with PCS is unknown. OBJECTIVE: The aim of this study was to identify potential cardiac inflammatory sequelae in children with PCS compared with healthy controls. METHODS: This single-center, prospective, intraindividual, observational study assesses cardiac function, global and segment-based strains, and tissue characterization in 29 age- and sex-matched children with PCS and healthy children using a 3 T magnetic resonance imaging (MRI). RESULTS: Cardiac MRI was carried out over 36.4 ± 24.9 weeks post-COVID infection. The study cohort has an average age of 14.0 ± 2.8 years, for which the majority of individuals experience from fatigue, concentration disorders, dyspnea, dizziness, and muscle ache. Children with PSC in contrast to the control group exhibited elevated heart rate (83.7 ± 18.1 beats per minute vs 75.2 ± 11.2 beats per minute, P = 0.019), increased indexed right ventricular end-diastolic volume (95.2 ± 19.2 mlm -2 vs 82.0 ± 21.5 mlm -2 , P = 0.018) and end-systolic volume (40.3 ± 7.9 mlm -2 vs 34.8 ± 6.2 mlm -2 , P = 0.005), and elevated basal and midventricular T1 and T2 relaxation times ( P < 0.001 to P = 0.013). Based on the updated Lake Louise Criteria, myocardial inflammation is present in 20 (69%) children with PCS. No statistically significant difference was observed for global strains. CONCLUSIONS: Cardiac MRI revealed altered right ventricular volumetrics and elevated T1 and T2 mapping values in children with PCS, suggestive for a diffuse myocardial inflammation, which may be useful for the diagnostic workup of PCS in children.


Assuntos
COVID-19 , Imageamento por Ressonância Magnética , Humanos , Masculino , Feminino , COVID-19/diagnóstico por imagem , COVID-19/complicações , Adolescente , Estudos Prospectivos , Criança , Imageamento por Ressonância Magnética/métodos , SARS-CoV-2 , Estudos de Casos e Controles , Síndrome de COVID-19 Pós-Aguda , Coração/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA