1.
J Synchrotron Radiat ; 25(Pt 5): 1548-1555, 2018 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-30179196

RESUMO

The research program at the biomedical imaging facility requires a high-flux hard-X-ray monochromator that can also provide a wide beam. A wide energy range is needed for standard radiography, phase-contrast imaging, K-edge subtraction imaging and monochromatic beam therapy modalities. The double-crystal Laue monochromator, developed for the BioMedical Imaging and Therapy facility, is optimized for the imaging of medium- and large-scale samples at high energies with the resolution reaching 4 µm. A pair of 2 mm-thick Si(111) bent Laue-type crystals were used in fixed-exit beam mode with a 16 mm vertical beam offset and the first crystal water-cooled. The monochromator operates at energies from 25 to 150 keV, and the measured size of the beam is 189 mm (H) × 8.6 mm (V) at 55 m from the source. This paper presents our approach in developing a complete focusing model of the monochromator. The model uses mechanical properties of crystals and benders to obtain a finite-element analysis of the complete assembly. The modeling results are compared and calibrated with experimental measurements. Using the developed analysis, a rough estimate of the bending radius and virtual focus (image) position of the first crystal can be made, which is also the real source for the second crystal. On the other hand, by measuring the beam height in several points in the SOE-1 hutch, the virtual focus of the second crystal can be estimated. The focusing model was then calibrated with measured mechanical properties, the values for the force and torque applied to the crystals were corrected, and the actual operating parameters of the monochromator for fine-tuning were provided.

2.
Langmuir ; 33(49): 13990-13995, 2017 12 12.
Artigo em Inglês | MEDLINE | ID: mdl-29064712

RESUMO

The nature of trapped air on submersed ultra-water-repellent interfaces has been investigated. These gaseous layers (plastrons) can last from hours to, in some examples such as the Salvinia molesta fern, months. The interface of submerged superhydrophobic surfaces with carefully controlled micropatterned surface roughness has been probed using synchrotron-based high-resolution X-ray phase tomography. This technique looks in situ, through the aqueous/gas interface in three dimensions. Long-term plastron stability appears to correlate with the appearance of scattered microdroplets <20 µm in diameter that are sandwiched within the 30 µm thick gaseous interfacial layer. These microdroplets are centered on defects or damaged sections within the substrate surface approximately 20-50 µm apart. Such irregularities represent heterogeneous micro/nano-hierarchical structures with varying surface structures and chemistry. The stability of microdroplets is governed by a combination of electrostatic repulsion, contact angle limitations, and a saturated vapor pressure, the latter of which reduces the rate of diffusion of gas out of the air layer, thus increasing underwater longevity. Homogenous surfaces exhibiting purely nano- or micro-regularity do not support such microdroplets, and, as a consequence, plastrons can disappear in <20 h compared with >160 h for surfaces with scattered microdroplets. Such behavior may be a requirement for long-term nonwetting in any system.

3.
Proc Natl Acad Sci U S A ; 111(35): 12930-5, 2014 Sep 02.
Artigo em Inglês | MEDLINE | ID: mdl-25136096

RESUMO

Cystic fibrosis (CF) is an autosomal recessive genetic disorder caused by mutations in the gene encoding for the anion channel cystic fibrosis transmembrane conductance regulator (CFTR). Several organs are affected in CF, but most of the morbidity and mortality comes from lung disease. Recent data show that the initial consequence of CFTR mutation is the failure to eradicate bacteria before the development of inflammation and airway remodeling. Bacterial clearance depends on a layer of airway surface liquid (ASL) consisting of both a mucus layer that traps, kills, and inactivates bacteria and a periciliary liquid layer that keeps the mucus at an optimum distance from the underlying epithelia, to maximize ciliary motility and clearance of bacteria. The airways in CF patients and animal models of CF demonstrate abnormal ASL secretion and reduced antimicrobial properties. Thus, it has been proposed that abnormal ASL secretion in response to bacteria may facilitate the development of the infection and inflammation that characterize CF airway disease. Whether the inhalation of bacteria triggers ASL secretion, and the role of CFTR, have never been tested, however. We developed a synchrotron-based imaging technique to visualize the ASL layer and measure the effect of bacteria on ASL secretion. We show that the introduction of Pseudomonas aeruginosa and other bacteria into the lumen of intact isolated swine tracheas triggers CFTR-dependent ASL secretion by the submucosal glands. This response requires expression of the bacterial protein flagellin. In patients with CF, the inhalation of bacteria would fail to trigger ASL secretion, leading to infection and inflammation.


Assuntos
Regulador de Condutância Transmembrana em Fibrose Cística/metabolismo , Fibrose Cística/microbiologia , Infecções por Pseudomonas/metabolismo , Pseudomonas aeruginosa/metabolismo , Traqueia/metabolismo , Traqueia/microbiologia , Animais , Fibrose Cística/imunologia , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/imunologia , Feminino , Haemophilus influenzae/metabolismo , Imunidade Inata/fisiologia , Masculino , Mucinas/metabolismo , Infecções por Pseudomonas/imunologia , Mucosa Respiratória/imunologia , Mucosa Respiratória/metabolismo , Mucosa Respiratória/microbiologia , Staphylococcus aureus/metabolismo , Suínos , Síncrotrons , Traqueia/imunologia
4.
J Synchrotron Radiat ; 22(4): 946-55, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-26134798

RESUMO

The stability of the photon beam position on synchrotron beamlines is critical for most if not all synchrotron radiation experiments. The position of the beam at the experiment or optical element location is set by the position and angle of the electron beam source as it traverses the magnetic field of the bend-magnet or insertion device. Thus an ideal photon beam monitor would be able to simultaneously measure the photon beam's position and angle, and thus infer the electron beam's position in phase space. X-ray diffraction is commonly used to prepare monochromatic beams on X-ray beamlines usually in the form of a double-crystal monochromator. Diffraction couples the photon wavelength or energy to the incident angle on the lattice planes within the crystal. The beam from such a monochromator will contain a spread of energies due to the vertical divergence of the photon beam from the source. This range of energies can easily cover the absorption edge of a filter element such as iodine at 33.17 keV. A vertical profile measurement of the photon beam footprint with and without the filter can be used to determine the vertical centroid position and angle of the photon beam. In the measurements described here an imaging detector is used to measure these vertical profiles with an iodine filter that horizontally covers part of the monochromatic beam. The goal was to investigate the use of a combined monochromator, filter and detector as a phase-space beam position monitor. The system was tested for sensitivity to position and angle under a number of synchrotron operating conditions, such as normal operations and special operating modes where the photon beam is intentionally altered in position and angle at the source point. The results are comparable with other methods of beam position measurement and indicate that such a system is feasible in situations where part of the synchrotron beam can be used for the phase-space measurement.


Assuntos
Síncrotrons , Cristalografia por Raios X , Fótons
5.
J Synchrotron Radiat ; 22(5): 1297-300, 2015 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-26289283

RESUMO

High-resolution computed tomography (CT) imaging of a live animal within a lead-lined synchrotron light hutch presents several unique challenges. In order to confirm that the animal is under a stable plane of anaesthesia, several physiological parameters (e.g. heart rate, arterial oxygen saturation, core body temperature and respiratory rate) must be remotely monitored from outside the imaging hutch. In addition, to properly scan the thoracic region using CT, the animal needs to be held in a vertical position perpendicular to the fixed angle of the X-ray beam and free to rotate 180°-360°. A new X-ray transparent mouse restraint designed and fabricated using computer-aided design software and three-dimensional rapid prototype printing has been successfully tested at the Biomedical Imaging and Therapy bending-magnet (BMIT-BM) beamline at the Canadian Light Source.


Assuntos
Camundongos , Restrição Física/instrumentação , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Animais , Desenho Assistido por Computador , Cruzamentos Genéticos , Desenho de Equipamento , Camundongos Endogâmicos BALB C , Camundongos Endogâmicos C57BL , Miniaturização , Impressão Tridimensional , Organismos Livres de Patógenos Específicos
6.
Biomed Eng Online ; 14: 91, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26481447

RESUMO

BACKGROUND: The observation of ultrasound generated cavitation bubbles deep in tissue is very difficult. The development of an imaging method capable of investigating cavitation bubbles in tissue would improve the efficiency and application of ultrasound in the clinic. Among the previous imaging modalities capable of detecting cavitation bubbles in vivo, the acoustic detection technique has the positive aspect of in vivo application. However the size of the initial cavitation bubble and the amplitude of the ultrasound that produced the cavitation bubbles, affect the timing and amplitude of the cavitation bubbles' emissions. METHODS: The spatial distribution of cavitation bubbles, driven by 0.8835 MHz therapeutic ultrasound system at output power of 14 Watt, was studied in water using a synchrotron X-ray imaging technique, Analyzer Based Imaging (ABI). The cavitation bubble distribution was investigated by repeated application of the ultrasound and imaging the water tank. The spatial frequency of the cavitation bubble pattern was evaluated by Fourier analysis. Acoustic cavitation was imaged at four different locations through the acoustic beam in water at a fixed power level. The pattern of cavitation bubbles in water was detected by synchrotron X-ray ABI. RESULTS: The spatial distribution of cavitation bubbles driven by the therapeutic ultrasound system was observed using ABI X-ray imaging technique. It was observed that the cavitation bubbles appeared in a periodic pattern. The calculated distance between intervals revealed that the distance of frequent cavitation lines (intervals) is one-half of the acoustic wave length consistent with standing waves. CONCLUSION: This set of experiments demonstrates the utility of synchrotron ABI for visualizing cavitation bubbles formed in water by clinical ultrasound systems working at high frequency and output powers as low as a therapeutic system.


Assuntos
Imagem Óptica/métodos , Terapia por Ultrassom , Imagem Óptica/instrumentação , Síncrotrons , Raios X
7.
J Synchrotron Radiat ; 21(Pt 3): 479-83, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24763635

RESUMO

The Biomedical Imaging and Therapy (BMIT) beamline at the Canadian Light Source has produced some excellent biological imaging data. However, the disadvantage of a small vertical beam limits its usability in some applications. Micro-computed tomography (micro-CT) imaging requires multiple scans to produce a full projection, and certain dynamic imaging experiments are not possible. A larger vertical beam is desirable. It was cost-prohibitive to build a longer beamline that would have produced a large vertical beam. Instead, it was proposed to develop a beam expander that would create a beam appearing to originate at a source much farther away. This was accomplished using a bent Laue double-crystal monochromator in a non-dispersive divergent geometry. The design and implementation of this beam expander is presented along with results from the micro-CT and dynamic imaging tests conducted with this beam. Flux (photons per unit area per unit time) has been measured and found to be comparable with the existing flat Bragg double-crystal monochromator in use at BMIT. This increase in overall photon count is due to the enhanced bandwidth of the bent Laue configuration. Whilst the expanded beam quality is suitable for dynamic imaging and micro-CT, further work is required to improve its phase and coherence properties.


Assuntos
Intensificação de Imagem Radiográfica/instrumentação , Refratometria/instrumentação , Síncrotrons/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Raios X
8.
PLoS One ; 18(10): e0291757, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37788257

RESUMO

Accurate evaluation of morphological changes in articular cartilage are necessary for early detection of osteoarthritis (OA). 3T magnetic resonance imaging (MRI) has highly sensitive contrast resolution and is widely used clinically to detect OA. However, synchrotron radiation phase-contrast imaging computed tomography (SR-PCI) can also provide contrast to tissue interfaces that do not have sufficient absorption differences, with the added benefit of very high spatial resolution. Here, MRI was compared with SR-PCI for quantitative evaluation of human articular cartilage. Medial tibial condyles were harvested from non-OA donors and from OA patients receiving knee replacement surgery. Both imaging methods revealed that average cartilage thickness and cartilage volume were significantly reduced in the OA group, compared to the non-OA group. When comparing modalities, the superior resolution of SR-PCI enabled more precise mapping of the cartilage surface relative to MRI. As a result, MRI showed significantly higher average cartilage thickness and cartilage volume, compared to SR-PCI. These data highlight the potential for high-resolution imaging of articular cartilage using SR-PCI as a solution for early OA diagnosis. Recognizing current limitations of using a synchrotron for clinical imaging, we discuss its nascent utility for preclinical models, particularly longitudinal studies of live animal models of OA.


Assuntos
Cartilagem Articular , Osteoartrite do Joelho , Intervenção Coronária Percutânea , Animais , Humanos , Cartilagem Articular/diagnóstico por imagem , Osteoartrite do Joelho/diagnóstico por imagem , Síncrotrons , Imageamento por Ressonância Magnética/métodos , Articulação do Joelho/diagnóstico por imagem
9.
Med Phys ; 39(2): 608-22, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22320770

RESUMO

PURPOSE: Theoretical reasoning suggests that direct conversion digital x-ray detectors based upon photoconductive amorphous-selenium (a-Se) could attain very high values of the MTF (modulation transfer function) at spatial frequencies well beyond 20 cycles mm(-1). One of the fundamental factors affecting resolution loss, particularly at x-ray energies just above the K-edge of selenium (12.66 keV), is the K-fluorescence reabsorption mechanism, wherein energy can be deposited in the detector at locations laterally displaced from the initial x-ray interaction site. This paper compares measured MTF changes above and below the Se K-edge of a CCD based a-Se x-ray detector with theoretical expectations. METHODS: A prototype 25 µm sampling pitch (Nyquist frequency = 20 cycles mm(-1), 200 µm thick a-Se layer based x-ray detector, utilizing a specialized CCD readout device (200 × 400 area array), was used to make edge images with monochromatic x-rays above and below the K-edge of Se. A vacuum double crystal monochromator, exposed to polychromatic x-rays from a synchrotron, formed the monochromatic x-ray source. The monochromaticity of the x-rays was 99% or better. The presampling MTF was determined using the slanted edge method. The theory modeling the MTF performance of the detector includes the basic x-ray interaction physics in the a-Se layer as well as effects related to the operation of the CCD and charge trapping at a blocking layer present at the CCD/a-Se interface. RESULTS: The MTF performance of the prototype a-Se CCD was reduced from the theoretical value prescribed by the basic Se x-ray interaction physics, principally by the presence of a blocking layer. Nevertheless, the K-fluorescence reduction in the MTF was observed, approximately as predicted by theory. For the CCD prototype detector, at five cycles mm(-1), there was a 14% reduction of the MTF, from a value of 0.7 below the K-edge of Se, to 0.6 just above the K-edge. CONCLUSIONS: The MTF of an a-Se x-ray detector has been measured using monochromatic x-rays above and below the K-edge of selenium. The MTF is poorer above the K-edge by an amount consistent with theoretical expectations.


Assuntos
Modelos Teóricos , Selênio/efeitos da radiação , Processamento de Sinais Assistido por Computador/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Desenho Assistido por Computador , Desenho de Equipamento , Análise de Falha de Equipamento , Fluorescência
10.
Sci Rep ; 12(1): 2951, 2022 02 22.
Artigo em Inglês | MEDLINE | ID: mdl-35194092

RESUMO

More than 2 million years ago in East Africa, the earliest hominin stone tools evolved amidst changes in resource base, with pounding technology playing a key role in this adaptive process. Olduvai Gorge (now Oldupai) is a famed locality that remains paramount for the study of human evolution, also yielding some of the oldest battering tools in the world. However, direct evidence of the resources processed with these technologies is lacking entirely. One way to obtain this evidence is through the analysis of surviving residues. Yet, linking residues with past processing activities is not simple. In the case of plant exploitation, this link can only be established by assessing site-based reference collections inclusive of both anthropogenic and natural residues as a necessary first step and comparative starting point. In this paper, we assess microbotanical remains from rock clasts sourced at the same quarry utilized by Oldowan hominins at Oldupai Gorge. We mapped this signal and analysed it quantitatively to classify its spatial distribution objectively, extracting proxies for taxonomic identification and further comparison with freestanding soils. In addition, we used blanks to manufacture pounding tools for blind, controlled replication of plant processing. We discovered that stone blanks are in fact environmental reservoirs in which plant remains are trapped by lithobionts, preserved as hardened accretions. Tool use, on the other hand, creates residue clusters; however, their spatial distribution can be discriminated from purely natural assemblages by the georeferencing of residues and statistical analysis of resulting patterns. To conclude, we provide a protocol for best practice and a workflow that has the advantage of overcoming environmental noise, reducing the risk of false positive, delivering a firm understanding of residues as polygenic mixtures, a reliable use of controls, and most importantly, a stronger link between microbotanical remains and stone tool use.

11.
Sensors (Basel) ; 11(5): 5112-57, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-22163893

RESUMO

In the last ten to fifteen years there has been much research in using amorphous and polycrystalline semiconductors as x-ray photoconductors in various x-ray image sensor applications, most notably in flat panel x-ray imagers (FPXIs). We first outline the essential requirements for an ideal large area photoconductor for use in a FPXI, and discuss how some of the current amorphous and polycrystalline semiconductors fulfill these requirements. At present, only stabilized amorphous selenium (doped and alloyed a-Se) has been commercialized, and FPXIs based on a-Se are particularly suitable for mammography, operating at the ideal limit of high detective quantum efficiency (DQE). Further, these FPXIs can also be used in real-time, and have already been used in such applications as tomosynthesis. We discuss some of the important attributes of amorphous and polycrystalline x-ray photoconductors such as their large area deposition ability, charge collection efficiency, x-ray sensitivity, DQE, modulation transfer function (MTF) and the importance of the dark current. We show the importance of charge trapping in limiting not only the sensitivity but also the resolution of these detectors. Limitations on the maximum acceptable dark current and the corresponding charge collection efficiency jointly impose a practical constraint that many photoconductors fail to satisfy. We discuss the case of a-Se in which the dark current was brought down by three orders of magnitude by the use of special blocking layers to satisfy the dark current constraint. There are also a number of polycrystalline photoconductors, HgI(2) and PbO being good examples, that show potential for commercialization in the same way that multilayer stabilized a-Se x-ray photoconductors were developed for commercial applications. We highlight the unique nature of avalanche multiplication in a-Se and how it has led to the development of the commercial HARP video-tube. An all solid state version of the HARP has been recently demonstrated with excellent avalanche gains; the latter is expected to lead to a number of novel imaging device applications that would be quantum noise limited. While passive pixel sensors use one TFT (thin film transistor) as a switch at the pixel, active pixel sensors (APSs) have two or more transistors and provide gain at the pixel level. The advantages of APS based x-ray imagers are also discussed with examples.


Assuntos
Eletrônica/instrumentação , Raios X , Desenho de Equipamento , Ecrans Intensificadores para Raios X
12.
J Dev Biol ; 9(1)2021 Mar 12.
Artigo em Inglês | MEDLINE | ID: mdl-33809066

RESUMO

For humans and other mammals to eat effectively, teeth must develop properly inside the jaw. Deciphering craniodental integration is central to explaining the timely formation of permanent molars, including third molars which are often impacted in humans, and to clarifying how teeth and jaws fit, function and evolve together. A factor long-posited to influence molar onset time is the jaw space available for each molar organ to form within. Here, we tested whether each successive molar initiates only after a minimum threshold of space is created via jaw growth. We used synchrotron-based micro-CT scanning to assess developing molars in situ within jaws of C57BL/6J mice aged E10 to P32, encompassing molar onset to emergence. We compared total jaw, retromolar and molar lengths, and molar onset times, between upper and lower jaws. Initiation time and developmental duration were comparable between molar upper and lower counterparts despite shorter, slower-growing retromolar space in the upper jaw, and despite size differences between upper and lower molars. Timing of molar formation appears unmoved by jaw length including space. Conditions within the dental lamina likely influence molar onset much more than surrounding jaw tissues. We theorize that molar initiation is contingent on sufficient surface area for the physical reorganization of dental epithelium and its invagination of underlying mesenchyme.

13.
Food Res Int ; 130: 108919, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32156367

RESUMO

Globally, the bakery industry has a target of reducing sodium content in bread products. However, removing salt results in changes in the quality of bread through effects on dough's gas phase during the breadmaking process. Using synchrotron X-ray microtomography, the objective of this study was to investigate how sodium reduction induced changes in the gas phase parameters (i.e., gas volume fraction, bubble size distribution (BSD) and its time evolution) of non-yeasted doughs made from a wide range of formulations (i.e., wheat cultivar and water content) prepared with different mixing times. As salt content was reduced, a lower gas volume was retained in the dough by the end of mixing. Less gas bubbles were also retained if doughs were prepared from a stronger wheat cultivar, higher water content, and/or mixed for a shorter time. Rates of change in the median (R0) and the width (ε) of the fitted lognormal radius dependence of bubble volume fraction [BVF(R)] indicated that reduced sodium content permitted disproportionation to proceed more rapidly. Higher water content or longer mixing time also resulted in faster disproportionation, indicating that water content and mixing time can be manipulated as a means of increasing bubble stability against disproportionation during low-sodium breadmaking. An examination of relative changes in dough's gas phase parameters arising from sodium reduction demonstrated that wheat cultivar, water content and mixing time all affected dough's tolerance to sodium reduction. Therefore, attainment of good bread crumb cell structure in low-sodium bread formulas is a function of salt's effects on dough rheology in addition to its effect on yeast activity, so that dough formulation and mixing conditions also need to be considered.


Assuntos
Pão/análise , Manipulação de Alimentos/métodos , Sódio/química , Microtomografia por Raio-X/métodos , Farinha , Síncrotrons
14.
Rev Sci Instrum ; 90(3): 035104, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30927807

RESUMO

X-ray image formation using scattered radiation can yield a superior contrast-to-noise ratio compared to conventional transmission x-ray imaging. A barrier to practical implementation of scatter imaging systems has been slow image acquisition. We have developed a projection imaging system which uses five monoenergetic pencil beams in combination with continuous phantom motion to achieve acquisition times that are practical for medical and security applications. The system was configured at the Canadian Light Source synchrotron and consists of a primary collimator, motorized stages for phantom translation, a flat-panel x-ray detector for measuring scattered x rays, and photodiodes for simultaneously measuring transmitted x rays. Image generation requires several corrections to raw data artifacts arising from the nature of the detector, x-ray source, and acquisition procedure. We developed a novel correction for pixel location inaccuracy arising from continuous phantom motion. A five-beam system had nearly five times faster acquisition than a single-beam system. Continuous motion acquisition was approximately 30 times faster than step-and-shoot acquisition. The total acquisition time for a 9 cm × 5 cm phantom with 8425 pixels was just over 2 min. Image quality was also assessed, in part to determine its relation to acquisition speed. The width of sharp material boundaries was found to be at a minimum equal to the pencil beam width (1.75 mm) and to have an additional width equal to the product of the phantom translation speed and the acquisition time per pixel (up to 1.0 mm in our experiments). Contrast-detail performance was independent of acquisition speed, depending only on phantom entrance x-ray fluence. Pixel signal-to-noise ratio measurements indicate that detector readout noise is important for the scatter data, even for phantom air kerma as high as 30 mGy. Images could be improved with a detector having lower readout noise and higher sensitivity. Its spatial resolution could be moderate. We confirmed that for the same range of λ-1 sin(θ/2), where λ is the x-ray wavelength and θ is the scattering angle, scatter images acquired using different beam energies (33-70 keV) had nearly identical contrast.

15.
Materials (Basel) ; 12(20)2019 Oct 18.
Artigo em Inglês | MEDLINE | ID: mdl-31635272

RESUMO

Single-event effects (SEEs) in integrated circuits and devices can be studied by utilizing ultra-fast pulsed laser system through Two Photon Absorption process. This paper presents technical ways to characterize key factors for laser based SEEs mapping testing system: output power from laser source, spot size focused by objective lens, opening window of Pockels cell, and calibration of injected laser energy. The laser based SEEs mapping testing system can work in a stable and controllable status by applying these methods. Furthermore, a sensitivity map of a Static Random Access Memory (SRAM) cell with a 65 nm technique node was created through the established laser system. The sensitivity map of the SRAM cell was compared to a map generated by a commercial simulation tool (TFIT), and the two matched well. In addition, experiments in this paper also provided energy distribution profile along Z axis that is the direction of the pulsed laser injection and threshold energy for different SRAM structures.

16.
Med Eng Phys ; 73: 1-8, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31526590

RESUMO

Understanding hip osteoarthritis requires new investigational tools for quantitative studies of biophysical and biomechanical properties as well as for determination of structure. Three new protocols to study pathological changes in cartilage and to measure cartilage thickness in intact human hips are described using synchrotron contrast enhanced computed tomography (sCECT) with the iodinated contrast agent CA4+. Ten human cadaver hips were prepared and injected with CA4+ using three different methods, all of which included rotation and distraction of the joint. CA4+ diffusion into cartilage was monitored using sCECT. The thickness of acetabular and femoral cartilage was also measured. Diffusion times ranged from 2 h to 75 h, depending on the injection protocol and the cartilage region. Direct single injection of the contrast through the labrum resulted in the fastest diffusion times. The iodine attenuation coefficient, which reflects the contrast agent distribution in the cartilage, ranged from 0.0142/cm to 0.1457/cm. Three injections at the head/neck conjunction area yielded the highest iodine attenuation coefficients in cartilage. The femoral cartilage in the Superior-Medial compartment was significantly thicker than in the other 3 femoral compartments, and femoral cartilage in the Superior-Anterior compartment was significantly thinner than the other 3 femoral compartments. The acetabular cartilage in the Superior compartment was significantly thicker than that in the Superior-Posterior compartment. sCECT with CA4+ allows assessment of hip cartilage thickness with 0.1 mm isotropic voxel size, sufficient for evaluating cartilage pathology and biomechanics.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Meios de Contraste , Articulação do Quadril/diagnóstico por imagem , Síncrotrons , Tomografia Computadorizada por Raios X/instrumentação , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
17.
Sci Rep ; 9(1): 540, 2019 01 24.
Artigo em Inglês | MEDLINE | ID: mdl-30679487

RESUMO

Inhaled hypertonic saline (HTS) treatment is used to improve lung health in patients with cystic fibrosis (CF). The current consensus is that the treatment generates an osmotic gradient that draws water into the airways and increases airway surface liquid (ASL) volume. However, there is evidence that HTS may also stimulate active secretion of ASL by airway epithelia through the activation of sensory neurons. We tested the contribution of the nervous system and airway epithelia on HTS-stimulated ASL height increase in CF and wild-type swine airway. We used synchrotron-based imaging to investigate whether airway neurons and epithelia are involved in HTS treatment-triggered ASL secretion in CFTR-/- and wild-type swine. We showed that blocking parasympathetic and sensory neurons in airway resulted in ~50% reduction of the effect of HTS treatment on ASL volume in vivo. Incubating tracheal preparations with inhibitors of epithelial ion transport across airway decreased secretory responses to HTS treatment. CFTR-/- swine ex-vivo tracheal preparations showed substantially decreased secretory response to HTS treatment after blockage of neuronal activity. Our results indicated that HTS-triggered ASL secretion is partially mediated by the stimulation of airway neurons and the subsequent activation of active epithelia secretion; osmosis accounts for only ~50% of the effect.


Assuntos
Fibrose Cística/tratamento farmacológico , Fibrose Cística/metabolismo , Cisto Mediastínico/tratamento farmacológico , Cisto Mediastínico/metabolismo , Solução Salina Hipertônica/uso terapêutico , Células Receptoras Sensoriais/efeitos dos fármacos , Células Receptoras Sensoriais/metabolismo , Administração por Inalação , Animais , Animais Geneticamente Modificados , Secreções Corporais/efeitos dos fármacos , Secreções Corporais/metabolismo , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Feminino , Técnicas de Inativação de Genes , Transporte de Íons/efeitos dos fármacos , Masculino , Osmose/efeitos dos fármacos , Mucosa Respiratória/efeitos dos fármacos , Mucosa Respiratória/metabolismo , Solução Salina Hipertônica/administração & dosagem , Solução Salina Hipertônica/farmacologia , Suínos
18.
Elife ; 62017 11 21.
Artigo em Inglês | MEDLINE | ID: mdl-29157359

RESUMO

Blood-sucking insects experience thermal stress at each feeding event on endothermic vertebrates. We used thermography to examine how kissing-bugs Rhodnius prolixus actively protect themselves from overheating. During feeding, these bugs sequester and dissipate the excess heat in their heads while maintaining an abdominal temperature close to ambient. We employed a functional-morphological approach, combining histology, µCT and X-ray-synchrotron imaging to shed light on the way these insects manage the flow of heat across their bodies. The close alignment of the circulatory and ingestion systems, as well as other morphological characteristics, support the existence of a countercurrent heat exchanger in the head of R. prolixus, which decreases the temperature of the ingested blood before it reaches the abdomen. This kind of system has never been described before in the head of an insect. For the first time, we show that countercurrent heat exchange is associated to thermoregulation during blood-feeding.


Assuntos
Rhodnius/fisiologia , Animais , Regulação da Temperatura Corporal , Comportamento Alimentar , Cabeça/fisiologia , Histocitoquímica , Temperatura Alta , Estresse Fisiológico , Microtomografia por Raio-X
19.
Nat Commun ; 8(1): 786, 2017 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-28983075

RESUMO

Cystic fibrosis is caused by mutations in the gene encoding the cystic fibrosis transmembrane conductance regulator (CFTR) channel, which can result in chronic lung disease. The sequence of events leading to lung disease is not fully understood but recent data show that the critical pathogenic event is the loss of the ability to clear bacteria due to abnormal airway surface liquid secretion (ASL). However, whether the inhalation of bacteria triggers ASL secretion and whether this is abnormal in cystic fibrosis has never been tested. Here we show, using a novel synchrotron-based in vivo imaging technique, that wild-type pigs display both a basal and a Toll-like receptor-mediated ASL secretory response to the inhalation of cystic fibrosis relevant bacteria. Both mechanisms fail in CFTR-/- swine, suggesting that cystic fibrosis airways do not respond to inhaled pathogens, thus favoring infection and inflammation that may eventually lead to tissue remodeling and respiratory disease.Cystic fibrosis is caused by mutations in the CFTR chloride channel, leading to reduced airway surface liquid secretion. Here the authors show that exposure to bacteria triggers secretion in wild-type but not in pig models of cystic fibrosis, suggesting an impaired response to pathogens contributes to infection.


Assuntos
Fibrose Cística/metabolismo , Pulmão/metabolismo , Pseudomonas aeruginosa , Mucosa Respiratória/metabolismo , Animais , Fibrose Cística/genética , Regulador de Condutância Transmembrana em Fibrose Cística/genética , Modelos Animais de Doenças , Exposição por Inalação , Pulmão/diagnóstico por imagem , Masculino , Radiografia , Suínos
20.
Data Brief ; 6: 644-51, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26909381

RESUMO

This article presents the data of using three phase-based X-ray imaging techniques to characterize biomaterial scaffold and soft tissues in situ, as reported in our study "Low-dose phase-based X-ray imaging techniques for in situ soft tissue engineering assessments" [1]. The examined parameters include the radiation dose, scan time, and image quality, which are all critical to longitudinal in situ live animal assessments. The data presented were obtained from three dimensional imaging of scaffolds in situ cartilage by means of synchrotron-based computed tomography-diffraction enhanced imaging (CT-DEI), analyzer based imaging (CT-ABI), and in-line phase contrast imaging (CT-PCI) at standard and low dose imaging modalities.

SELEÇÃO DE REFERÊNCIAS