Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 64
Filtrar
1.
Catheter Cardiovasc Interv ; 104(1): 1-9, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38713843

RESUMO

BACKGROUND: The BIONYX randomized trial is the first study to evaluate the Resolute Onyx durable polymer-coated zotarolimus-eluting stent (ZES) in all-comers. Furthermore, it is the first trial to assess safety and efficacy of this stent versus the Orsiro biodegradable-polymer sirolimus-eluting stent (SES) in all-comers, paying particular attention to patients with diabetes. It has previously shown promising results until 3 years of follow-up. AIMS: We aimed to assess long-term clinical outcome after percutaneous coronary intervention (PCI) with Onyx ZES versus Orsiro SES at 5-year follow-up. METHODS: The main composite endpoint was target vessel failure (TVF): cardiac death, target vessel myocardial infarction, or target vessel revascularization. Time to primary and secondary endpoints was assessed using Kaplan-Meier methods, applying the log-rank test for between-group comparison. RESULTS: Follow-up was available in 2414/2488 (97.0%) patients. After 5 years, TVF showed no significant difference between Onyx ZES and Orsiro SES (12.7% vs. 13.7%, hazard ratio [HR] 0.94, 95% confidence interval [CI] [0.75-1.17], plog-rank = 0.55). Landmark analysis between 3- and 5-year follow-up found a lower target lesion revascularization rate for Onyx ZES (1.1% vs. 2.4%, HR 0.47, 95% CI [0.24-0.93], plog-rank = 0.026). A prespecified subgroup analysis showed no significant between-stent difference in clinical outcome among patients with diabetes. After treatment with Onyx ZES, patients aged ≥75 years had significantly lower rates of TVF (13.8% vs. 21.9%, HR 0.60, 95% CI [0.39-0.93], plog-rank = 0.023). CONCLUSIONS: The final 5-year analysis of the randomized BIONYX trial showed favorable and similar long-term outcomes of safety and efficacy for Onyx ZES and Orsiro SES in both all-comers and patients with diabetes.


Assuntos
Fármacos Cardiovasculares , Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Desenho de Prótese , Sirolimo , Humanos , Sirolimo/administração & dosagem , Sirolimo/análogos & derivados , Sirolimo/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Masculino , Feminino , Resultado do Tratamento , Idoso , Fatores de Tempo , Fármacos Cardiovasculares/administração & dosagem , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Pessoa de Meia-Idade , Fatores de Risco , Cateteres Cardíacos , Estudos Prospectivos
2.
Neth Heart J ; 32(6): 254-261, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38776038

RESUMO

BACKGROUND: Several ethnic minorities have an increased risk of cardiovascular events, but previous European trials that investigated clinical outcome after coronary stenting did not assess the patients' ethnic background. AIMS: To compare ethnic minority and Western European trial participants in terms of both cardiovascular risk profile and 1­year clinical outcome after percutaneous coronary intervention. METHODS: In the BIO-RESORT and BIONYX randomised trials, which assessed new-generation drug-eluting stents, information on patients' self-reported ethnic background was prospectively collected. Pooled patient-level data of 5803 patients, enrolled in the Netherlands and Belgium, were analysed in this prespecified analysis. The main endpoint was target vessel failure after 1 year. RESULTS: Patients were classified as belonging to an ethnic minority (n = 293, 5%) or of Western European origin (n = 5510, 95%). Follow-up data were available in 5772 of 5803 (99.5%) patients. Ethnic minority patients were younger, less often female, more often current smokers, more often medically treated for diabetes, and more often had a positive family history of coronary artery disease. The main endpoint target vessel failure did not differ between ethnic minority and Western European patients (3.5% vs 4.9%, hazard ratio 0.71, 95% confidence interval 0.38-1.33; p = 0.28). There was also no difference in mortality, myocardial infarction, and repeat revascularisation rates. CONCLUSIONS: Despite the unfavourable cardiovascular risk profile of ethnic minority patients, short-term clinical outcome after treatment with contemporary drug-eluting stents was highly similar to that in Western European patients. Further efforts should be made to ensure the enrolment of more ethnic minority patients in future coronary stent trials.

3.
Circulation ; 143(22): 2143-2154, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33820424

RESUMO

BACKGROUND: Accelerated endothelial healing after targeted antiproliferative drug delivery may limit the long-term inflammatory response of drug-eluting stents (DESs). The novel Supreme DES is designed to synchronize early drug delivery within 4 to 6 weeks of implantation, leaving behind a prohealing permanent base layer. Whether the Supreme DES is safe and effective in the short term and can improve long-term clinical outcomes is not known. METHODS: In an international, 2:1 randomized, single-blind trial, we compared treatment with Supreme DES to durable polymer everolimus-eluting stents (DP-EES) in patients with acute and chronic coronary syndromes. The primary end point was target lesion failure-a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The trial was designed to demonstrate noninferiority (margin of 3.58%) of the Supreme DES at 12 months compared with DP-EES (URL: https://www.clinicaltrials.gov; Unique identifier: NCT03168776). RESULTS: From October 2017 to July 2019, a total of 1629 patients were randomly assigned (2:1) to the Supreme DES (N=1086) or DP-EES (N=543). At 12 months, target lesion failure occurred in 57 of 1057 patients (5.4%) in the Supreme DES group and in 27 of 532 patients (5.1%) in the DP-EES group (absolute risk difference, 0.32% [95% CI, -1.87 to 2.5]; Pnoninferiority=0.002]. There were no significant differences in rates of device success, clinically driven target lesion revascularization, or stent thrombosis at 12 months, and the safety composite of cardiovascular death and target vessel myocardial infarction was 3.5% versus 4.6% (hazard ratio, 0.76 [95% CI, 0.46-1.25]) with Supreme DES compared with DP-EES, although rates of combined clinically and non-clinically driven target lesion revascularization at 12 months were higher with Supreme DES. CONCLUSIONS: Among patients with acute and chronic coronary syndromes undergoing percutaneous coronary intervention, the Supreme DES proved to be noninferior to the standard DP-EES. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03168776.


Assuntos
Proliferação de Células/efeitos dos fármacos , Doença da Artéria Coronariana/terapia , Sistemas de Liberação de Medicamentos/métodos , Stents Farmacológicos/normas , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Adulto Jovem
4.
Am Heart J ; 246: 32-43, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-34990582

RESUMO

BACKGROUND: Current ESC guidelines recommend the use of intra-coronary pressure guidewires for functional assessment of intermediate-grade coronary stenoses. Angiography-derived quantitative flow ratio (QFR) is a novel method of assessing these stenoses, and guiding percutaneous coronary intervention (PCI). METHODS/DESIGN: The PIONEER IV trial is a prospective, all-comers, multi-center trial, which will randomize 2,540 patients in a 1:1 ratio to PCI guided by angiography-derived physiology or usual care, with unrestricted use in both arms of the Healing-Targeted Supreme sirolimus-eluting stent (HT Supreme). The stent's fast, biologically healthy, and robust endothelial coverage allows for short dual-antiplatelet therapy (DAPT); hence the antiplatelet regimen of choice is 1-month DAPT, followed by ticagrelor monotherapy. In the angiography-derived physiology guided arm, lesions will be functionally assessed using on-line QFR, with stenting indicated in lesions with a QFR ≤0.80. Post-stenting, QFR will be repeated in the stented vessel(s), with post-dilatation or additional stenting recommended if the QFR<0.91 distal to the stent, or if the delta QFR (across the stent) is >0.05. Usual care PCI is performed according to standard clinical practice. The primary endpoint is a non-inferiority comparison of the patient-oriented composite endpoint (POCE) of all-cause death, any stroke, any myocardial infarction, or any clinically, and physiologically driven revascularization with a non-inferiority risk-difference margin of 3.2%, at 1-year post-procedure. Clinical follow-up will be up to 3 years. SUMMARY: The PIONEER IV trial aims to demonstrate non-inferiority of QFR-guided PCI to usual care PCI with respect to POCE at 1-year in patients treated with HT Supreme stents and ticagrelor monotherapy. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov UNIQUE IDENTIFIER: NCT04923191 CLASSIFICATIONS: Interventional Cardiology.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/métodos , Estudos Prospectivos , Stents , Ticagrelor/uso terapêutico , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 100(1): 72-82, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35500171

RESUMO

BACKGROUND: Several studies have suggested that proton pump inhibitors (PPIs) may reduce the antiplatelet effects of clopidogrel and/or aspirin, possibly leading to cardiovascular events. AIMS: We aimed to investigate the association between PPI and clinical outcomes in patients treated with ticagrelor monotherapy or conventional antiplatelet therapy after percutaneous coronary intervention (PCI). METHODS: This is a subanalysis of the randomized GLOBAL LEADERS trial, comparing the experimental antiplatelet arm (23-month ticagrelor monotherapy following 1-month dual antiplatelet therapy [DAPT]) with the reference arm (12-month aspirin monotherapy following 12-month DAPT) after PCI. Patient-oriented composite endpoints (POCEs: all-cause mortality, myocardial infarction, stroke, or repeat revascularization) and its components were assessed stratified by PPI use as a time-dependent covariate in patients with the experiment or reference antiplatelet arm. RESULTS: Among 15,839 patients, 2115 patients (13.5%) experienced POCE at 2 years. In the reference arm, the use of PPIs was independently associated with POCE (hazard ratio [HR]: 1.27; 95% confidence interval [CI]: 1.12-1.44) and its individual components, whereas it was not in the experimental arm (HR: 1.04; 95% CI: 0.92-1.19; pinteraction = 0.035). During the second-year follow-up, patients taking aspirin with PPIs had a significantly higher risk of POCE compared to those on aspirin without PPIs (HR: 1.57; 95% CI: 1.27-1.94), whereas the risk did not differ significantly irrespective of PPI in ticagrelor monotherapy group (HR: 1.03; 95% CI: 0.83-1.28; pinteraction = 0.008). CONCLUSIONS: In contrast to conventional antiplatelet strategy, there were no evidence suggesting the interaction between ticagrelor monotherapy and PPIs on increased cardiovascular events, which should be confirmed in further studies. CLINICAL TRIAL REGISTRATION: URL: https://clinicaltrials.gov.


Assuntos
Infarto do Miocárdio , Intervenção Coronária Percutânea , Aspirina , Humanos , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Bomba de Prótons , Ticagrelor , Resultado do Tratamento
6.
Cardiovasc Diabetol ; 20(1): 217, 2021 10 30.
Artigo em Inglês | MEDLINE | ID: mdl-34717627

RESUMO

BACKGROUND: Diabetes is associated with adverse outcomes after percutaneous coronary intervention with drug-eluting stents (DES), but for prediabetes this association has not been definitely established. Furthermore, in patients with prediabetes treated with contemporary stents, bleeding data are lacking. We assessed 3-year ischemic and bleeding outcomes following treatment with new-generation DES in patients with prediabetes and diabetes as compared to normoglycemia. METHODS: For this post-hoc analysis, we pooled patient-level data of the BIO-RESORT and BIONYX stent trials which both stratified for diabetes at randomization. Both trials were multicenter studies performed in tertiary cardiac centers. Study participants were patients of whom glycemic state was known based on hemoglobin A1c, fasting plasma glucose, or medically treated diabetes. Three-year follow-up was available in 4212/4330 (97.3 %) patients. The main endpoint was target vessel failure, a composite of cardiac death, target vessel myocardial infarction, or target vessel revascularization. RESULTS: Baseline cardiovascular risk profiles were progressively abnormal in patients with normoglycemia, prediabetes, and diabetes. The main endpoint occurred in 54/489 patients with prediabetes (11.2 %) and 197/1488 with diabetes (13.7 %), as compared to 142/2,353 with normoglycemia (6.1 %) (HR: 1.89, 95 %-CI 1.38-2.58, p < 0.001, and HR: 2.30, 95 %-CI 1.85-2.86, p < 0.001, respectively). In patients with prediabetes, cardiac death and target vessel revascularization rates were significantly higher (HR: 2.81, 95 %-CI 1.49-5.30, p = 0.001, and HR: 1.92, 95 %-CI 1.29-2.87, p = 0.001), and in patients with diabetes all individual components of the main endpoint were significantly higher than in patients with normoglycemia (all p ≤ 0.001). Results were consistent after adjustment for confounders. Major bleeding rates were significantly higher in patients with prediabetes and diabetes, as compared to normoglycemia (3.9 % and 4.1 % vs. 2.3 %; HR:1.73, 95 %-CI 1.03-2.92, p = 0.040, and HR:1.78, 95 %-CI 1.23-2.57, p = 0.002). However, after adjustment for confounders, differences were no longer significant. CONCLUSIONS: Not only patients with diabetes but also patients with prediabetes represent a high-risk population. After treatment with new-generation DES, both patient groups had higher risks of ischemic and bleeding events. Differences in major bleeding were mainly attributable to dissimilarities in baseline characteristics. Routine assessment of glycemic state may help to identify patients with prediabetes for intensified management of cardiovascular risk factors. TRIAL REGISTRATION: BIO-RESORT ClinicalTrials.gov: NCT01674803, registered 29-08-2012; BIONYX ClinicalTrials.gov: NCT02508714, registered 27-7-2015.


Assuntos
Glicemia/metabolismo , Doença da Artéria Coronariana/terapia , Diabetes Mellitus/sangue , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Estado Pré-Diabético/sangue , Idoso , Glicemia/efeitos dos fármacos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/mortalidade , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/mortalidade , Feminino , Hemoglobinas Glicadas/metabolismo , Hemorragia/mortalidade , Humanos , Hipoglicemiantes/uso terapêutico , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estado Pré-Diabético/tratamento farmacológico , Estado Pré-Diabético/mortalidade , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 98(2): E188-E196, 2021 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-33694294

RESUMO

OBJECTIVES: To compare 2-year outcome following treatment with drug-eluting stents (DES) for acute myocardial infarction (MI) versus non-MI clinical syndromes. In acute MI patients, a stent-level comparison was performed, comparing Resolute Onyx versus Orsiro stents. BACKGROUND: In patients presenting with acute MI, higher adverse event rates have been reported. So far, no clinical results >1 year have been published of acute MI patients treated with Resolute Onyx. METHODS: This post-hoc analysis of the randomized BIONYX trial(NCT02508714) assessed the main outcome target vessel failure (TVF: cardiac death, target vessel MI, or target vessel revascularization) with Kaplan-Meier methods. RESULTS: Of all 2,488 trial participants, acute MI patients (n = 1,275[51.2%]) were significantly younger and had less comorbidities than non-MI patients (n = 1,213[48.8%]). TVF rates were lower in acute MI patients (77/1,275[6.1%] vs. 103/1,213[8.6%], HR:0.70, 95%-CI 0.52-0.94; plog-rank  = 0.02), mainly driven by target vessel revascularization (4.1 vs. 6.1%, plog-rank  = 0.03). Multivariate analysis showed no independent association of clinical syndrome with TVF (adjusted-HR: 0.81, 95%-CI 0.60-1.10; p = .17). In MI patients treated with Resolute Onyx (n = 626) versus Orsiro (n = 649), there was no difference in TVF (6.2 vs. 6.1%; plog-rank  = 0.97) and its components. There was only 1(0.2%) definite-or-probable stent thrombosis in RO-ZES and 8(1.2%) in O-SES (p = .053). CONCLUSIONS: Two years after treatment with thin-strut DES in this randomized trial, patients treated for acute MI had lower adverse event rates than non-MI patients. Yet, these findings were mainly attributable to between-group differences in patient and lesion characteristics. In patients who underwent PCI for acute MI, both Resolute Onyx and Orsiro showed favorable and similar 2-year outcomes.


Assuntos
Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Everolimo , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sirolimo , Stents , Resultado do Tratamento
8.
Circ J ; 85(11): 1983-1990, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34261828

RESUMO

BACKGROUND: At 1 year, the international randomized BIONYX trial (ClinicalTrials.gov:NCT02508714) established non-inferiority regarding safety and efficacy of the novel Resolute Onyx zotarolimus-eluting stent (RO-ZES) vs. the Orsiro sirolimus-eluting stent (O-SES). Although the RO-ZES is used in daily practice, no clinical results have been published beyond 2 years.Methods and Results:We assessed 3-year clinical outcomes of 2,488 all-comers after percutaneous coronary intervention (PCI) with RO-ZES vs. O-SES. The main endpoint was target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction (MI), or target vessel revascularization. Time-to-endpoints was assessed by Kaplan-Meier methods and between-group comparisons by log-rank tests. Follow-up was available in 2,433/2,488 (97.8%) patients. There was no significant between-stent difference in TVF (RO-ZES 112/1,243 [9.2%] vs. O-SES 109/1,245 [8.9%], hazard ratio [HR]: 1.03, 95% confidence interval [CI] 0.79-1.34; Plog-rank=0.85) and its individual components. The all-cause mortality was significantly lower after PCI with RO-ZES (3.7% vs.5.4%, HR: 0.67, 95% CI 0.46-0.97; Plog-rank=0.034), but cardiac mortality did not differ significantly (1.1% vs.1.9%, HR: 0.56, 95% CI 0.28-1.11; Plog-rank=0.09). Definite-or-probable stent thrombosis rates were low for both groups (0.6% vs.1.2%, HR: 0.46, 95% CI 0.19-1.14; Plog-rank=0.09). CONCLUSIONS: This first 3-year randomized assessment of the RO-ZES showed a favorable rate of TVF that matched the outcomes of patients treated with O-SES. We observed a lower rate of all-cause death in the RO-ZES group, but long-term clinical follow-up is of interest.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Stents , Resultado do Tratamento
9.
Am Heart J ; 228: 109-115, 2020 10.
Artigo em Inglês | MEDLINE | ID: mdl-32882569

RESUMO

BACKGROUND: Patients aged ≥80 years are often treated with new-generation drug-eluting stents (DES), but data from randomized studies are scarce owing to underrepresentation in most trials. We assessed 1-year clinical outcome of octogenarians treated with new-generation DES versus younger patients. METHODS: We pooled patient-level data of 9,204 participants in the TWENTE, DUTCH PEERS, BIO-RESORT, and BIONYX (TWENTE I-IV) randomized trials. The main clinical end point was target vessel failure (TVF), a composite of cardiac death, target vessel-related myocardial infarction (MI), or clinically indicated target vessel revascularization. RESULTS: The 671 octogenarian trial participants had significantly more comorbidities. TVF was higher in octogenarians than in 8,533 patients <80 years (7.3% vs 5.3%, hazard ratio [HR]: 1.36, 95% CI: 1.0-1.83, P = .04). The cardiac death rate was higher in octogenarians (3.9% vs 0.8%, P < .001). There was no significant between-group difference in target vessel MI (2.3% vs 2.3%, P = .88) and repeat target vessel revascularization (1.9% vs 2.8%, P = .16). In multivariate analyses, age ≥ 80 years showed no independent association with TVF (adjusted HR: 1.04, 95% CI: 0.76-1.42), whereas the risk of cardiac death remained higher in octogenarians (adjusted HR: 3.38, 95% CI: 2.07-5.52, P < .001). In 6,002 trial participants, in whom data on major bleeding were recorded, octogenarians (n = 459) showed a higher major bleeding risk (5.9% vs 1.9%; HR: 3.08, 95% CI: 2.01-4.74, P < .001). CONCLUSIONS: Octogenarian participants in 4 large-scale randomized DES trials had more comorbidities and a higher incidence of the main end point TVF. Cardiac mortality was higher in octogenarians, whereas there was no increase in MI or target vessel revascularization rates. Treatment of octogenarian patients with new-generation DES appears to be safe and effective.


Assuntos
Stents Farmacológicos/classificação , Everolimo/farmacologia , Infarto do Miocárdio , Complicações Pós-Operatórias , Sirolimo/análogos & derivados , Sirolimo/farmacologia , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/diagnóstico , Doença da Artéria Coronariana/cirurgia , Feminino , Humanos , Imunossupressores/farmacologia , Masculino , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/etiologia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/mortalidade , Reoperação/métodos , Reoperação/estatística & dados numéricos , Risco Ajustado/métodos , Fatores de Risco , Resultado do Tratamento
10.
Eur Heart J ; 40(31): 2595-2604, 2019 08 14.
Artigo em Inglês | MEDLINE | ID: mdl-31397487

RESUMO

AIMS: To evaluate the impact of an experimental strategy [23-month ticagrelor monotherapy following 1-month dual antiplatelet therapy (DAPT)] vs. a reference regimen (12-month aspirin monotherapy following 12-month DAPT) after complex percutaneous coronary intervention (PCI). METHODS AND RESULTS: In the present post hoc analysis of the Global Leaders trial, the primary endpoint [composite of all-cause death or new Q-wave myocardial infarction (MI)] at 2 years was assessed in patients with complex PCI, which includes at least one of the following characteristics: multivessel PCI, ≥3 stents implanted, ≥3 lesions treated, bifurcation PCI with ≥2 stents, or total stent length >60 mm. In addition, patient-oriented composite endpoint (POCE) (composite of all-cause death, any stroke, any MI, or any revascularization) and net adverse clinical events (NACE) [composite of POCE or Bleeding Academic Research Consortium (BARC) Type 3 or 5 bleeding] were explored. Among 15 450 patients included in this analysis, 4570 who underwent complex PCI had a higher risk of ischaemic and bleeding events. In patients with complex PCI, the experimental strategy significantly reduced risks of the primary endpoint [hazard ratio (HR): 0.64, 95% confidence interval (CI): 0.48-0.85] and POCE (HR: 0.80, 95% CI: 0.69-0.93), but not in those with non-complex PCI (Pinteraction = 0.015 and 0.017, respectively). The risk of BARC Type 3 or 5 bleeding was comparable (HR: 0.97, 95% CI: 0.67-1.40), resulting in a significant risk reduction in NACE (HR: 0.80, 95% CI: 0.69-0.92; Pinteraction = 0.011). CONCLUSION: Ticagrelor monotherapy following 1-month DAPT could provide a net clinical benefit for patients with complex PCI. However, in view of the overall neutral results of the trial, these findings of a post hoc analysis should be considered as hypothesis generating.


Assuntos
Síndrome Coronariana Aguda/terapia , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/métodos , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Ticagrelor/uso terapêutico , Idoso , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Estudos de Casos e Controles , Causas de Morte/tendências , Quimioterapia Combinada , Stents Farmacológicos/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/fisiopatologia , Infarto do Miocárdio/terapia , Revascularização Miocárdica/efeitos adversos , Revascularização Miocárdica/métodos , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Prospectivos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Acidente Vascular Cerebral/induzido quimicamente , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/mortalidade , Ticagrelor/efeitos adversos
11.
Lancet ; 392(10154): 1235-1245, 2018 10 06.
Artigo em Inglês | MEDLINE | ID: mdl-30253879

RESUMO

BACKGROUND: During the past decade, many patients had zotarolimus-eluting stents implanted, which had circular shape cobalt-chromium struts with limited radiographic visibility. The Resolute Onyx stent was developed to improve visibility while reducing strut thickness, which was achieved by using a novel composite wire with a dense platinum-iridium core and an outer cobalt-chromium layer. We did the first randomised clinical trial to assess the safety and efficacy of this often-used stent compared with the Orsiro stent, which consists of ultrathin cobalt-chromium struts. METHODS: We did an investigator-initiated, assessor-blinded and patient-blinded, randomised non-inferiority trial in an allcomers population at seven independently monitored centres in Belgium, Israel, and the Netherlands. Eligible participants were aged 18 years or older and required percutaneous coronary intervention with drug-eluting stents. After guide wire passage with or without predilation, members of the catheterisation laboratory team used web-based computer-generated allocation sequences to randomly assign patients (1:1) to either the Resolute Onyx or the Orsiro stent. Randomisation was stratified by sex and diabetes status. Patients and assessors were masked to allocated stents, but treating clinicians were not. The primary endpoint was target vessel failure at 1 year, a composite of cardiac death, target-vessel-related myocardial infarction, and target vessel revascularisation, and was assessed by intention to treat (non-inferiority margin 2·5%) on the basis of outcomes adjudicated by an independent event committee. This trial is registered with ClinicalTrials.gov, number NCT02508714. FINDINGS: Between Oct 7, 2015, and Dec 23, 2016, 2516 patients were enrolled, 2488 of whom were included in the intention-to-treat analysis (28 withdrawals or screening failures). 1243 participants were assigned to the Resolute Onyx group, and 1245 to the Orsiro group. Overall, 1765 (70·9%) participants presented with acute coronary syndromes and 1275 (51·2%) had myocardial infarctions. 1-year follow-up was available for 2478 (99·6%) patients. The primary endpoint was met by 55 (4·5%) patients in the Resolute Onyx group and 58 (4·7%) in the Orsiro group. Non-inferiority of Resolute Onyx to Orsiro was thus established (absolute risk difference -0·2% [95% CI -1·9 to 1·4]; upper limit of the one-sided 95% CI 1·1%; pnon-inferiority=0·0005). Definite or probable stent thrombosis occurred in one (0·1%) participant in the Resolute Onyx group and nine (0·7%) in the Orsiro group (hazard ratio 0·11 [95% CI 0·01-0·87]; p=0·0112). INTERPRETATION: The Resolute Onyx stent was non-inferior to Orsiro for a combined safety and efficacy endpoint at 1-year follow-up in allcomers. The low event rate in both groups suggests that both stents are safe, and the very low rate of stent thrombosis in the Resolute Onyx group warrants further clinical investigation. FUNDING: Biotronik and Medtronic.


Assuntos
Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Desenho de Prótese , Implantes Absorvíveis , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligas de Cromo , Stents Farmacológicos/efeitos adversos , Estudos de Equivalência como Asunto , Feminino , Seguimentos , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Polímeros , Estudos Prospectivos , Método Simples-Cego , Resultado do Tratamento
12.
Lancet ; 392(10151): 940-949, 2018 09 15.
Artigo em Inglês | MEDLINE | ID: mdl-30166073

RESUMO

BACKGROUND: We hypothesised that ticagrelor, in combination with aspirin for 1 month, followed by ticagrelor alone, improves outcomes after percutaneous coronary intervention compared with standard antiplatelet regimens. METHODS: GLOBAL LEADERS was a randomised, open-label superiority trial at 130 sites in 18 countries. Patients undergoing percutaneous coronary intervention with a biolimus A9-eluting stent for stable coronary artery disease or acute coronary syndromes were randomly assigned (1:1) to 75-100 mg aspirin daily plus 90 mg ticagrelor twice daily for 1 month, followed by 23 months of ticagrelor monotherapy, or standard dual antiplatelet therapy with 75-100 mg aspirin daily plus either 75 mg clopidogrel daily (for patients with stable coronary artery disease) or 90 mg ticagrelor twice daily (for patients with acute coronary syndromes) for 12 months, followed by aspirin monotherapy for 12 months. Randomisation was concealed, stratified by centre and clinical presentation (stable coronary artery disease vs acute coronary syndrome), and blocked, with randomly varied block sizes of two and four. The primary endpoint at 2 years was a composite of all-cause mortality or non-fatal centrally adjudicated new Q-wave myocardial infarction as assessed by a core lab in a blinded manner. The key secondary safety endpoint was site-reported bleeding assessed according to the Bleeding Academic Research Consortium criteria (grade 3 or 5). Analysis was by intention to treat. This trial is registered with ClinicalTrials.gov, number NCT01813435, and is closed to new participants, with follow-up completed. FINDINGS: Between July 1, 2013, and Nov 9, 2015, 15 968 participants were randomly assigned, 7980 to the experimental group and 7988 to the control group. At 2 years, 304 (3·81%) participants in the experimental group had died or had a non-fatal centrally adjudicated new Q-wave myocardial infarction, compared with 349 (4·37%) participants in the control group (rate ratio 0·87 [95% CI 0·75-1·01]; p=0·073]). There was no evidence for a difference in treatment effects for the primary endpoint across prespecified subgroups of acute coronary syndromes and stable coronary artery disease (p=0·93). Grade 3 or 5 bleeding occurred in 163 participants in the experimental group and 169 in the control group (2·04% vs 2·12%; rate ratio 0·97 [95% CI 0·78-1·20]; p=0·77). INTERPRETATION: Ticagrelor in combination with aspirin for 1 month followed by ticagrelor alone for 23 months was not superior to 12 months of standard dual antiplatelet therapy followed by 12 months of aspirin alone in the prevention of all-cause mortality or new Q-wave myocardial infarction 2 years after percutaneous coronary intervention. FUNDING: AstraZeneca, Biosensors, and The Medicines Company.


Assuntos
Adenosina/análogos & derivados , Aspirina/administração & dosagem , Doença da Artéria Coronariana , Stents Farmacológicos , Infarto do Miocárdio/mortalidade , Inibidores da Agregação Plaquetária/administração & dosagem , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Adenosina/administração & dosagem , Idoso , Clopidogrel , Angiografia Coronária , Doença da Artéria Coronariana/tratamento farmacológico , Doença da Artéria Coronariana/mortalidade , Quimioterapia Combinada , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Análise de Intenção de Tratamento , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/prevenção & controle , Intervenção Coronária Percutânea , Ticagrelor , Ticlopidina/administração & dosagem , Ticlopidina/análogos & derivados
13.
Acta Cardiol ; 74(1): 74-81, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29607737

RESUMO

BACKGROUND: Percutaneous left atrial appendage occlusion (LAAO) is an alternative to anticoagulation in atrial fibrillation patients at high bleeding risk. Dual antiplatelet therapy (DAPT) is generally recommended in the months following the procedure to prevent thrombotic complications. The aim of this study was to evaluate the safety and efficacy of DAPT after LAAO in a single-centre population of high bleeding risk patients. METHODS: All patients who received DAPT after LAAO using the Amplatzer Cardiac Plug at Jessa Hospital (Hasselt, BE) between February 2011 and October 2016 were included. Patient characteristics, procedural outcome and clinical events (bleeding, stroke and adverse events) were prospectively followed. Changes in antithrombotic and/or anticoagulant regimens were assessed. RESULTS: Thirty-nine patients (77 ± 7 years, 51% male, CHA2DS2-VASc 5(3-6), Hypertension, Abnormal Renal/Liver Function, Stroke, Bleeding History or Predisposition, Labile INR, Elderly, Drugs/Alcohol Concomitantly (HAS-BLED) 3(3-4)) were included. An initial strategy of one month DAPT (n = 2) was changed to six months DAPT (n = 37) after one thrombotic complication (device thrombosis) at 4.5 months. Post-procedural DAPT duration was 6.1 ± 3.7 months, after which aspirin monotherapy (62%), no antiplatelet/anticoagulant therapy (15%) or a tailored antithrombotic regimen was maintained. At mean follow-up of 21 ± 13 months, seven patients had died (18%), no strokes had occurred (0%) and nine bleedings of which four were major (10%). All major bleedings occurred within the first six months after the procedure during DAPT. CONCLUSION: Antithrombotic therapy after percutaneous LAAO is needed to prevent thrombotic complications, yet these impose bleeding complications in this high-risk population. Further efforts are needed to define the optimal duration of DAPT, aimed at reducing bleeding complications while maintaining a low thrombosis rate.


Assuntos
Aspirina/uso terapêutico , Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Clopidogrel/uso terapêutico , Sistema de Registros , Dispositivo para Oclusão Septal , Tromboembolia/prevenção & controle , Idoso , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Quimioterapia Combinada , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Masculino , Inibidores da Agregação Plaquetária/uso terapêutico , Estudos Retrospectivos , Fatores de Risco , Tromboembolia/etiologia , Fatores de Tempo , Resultado do Tratamento
14.
Am Heart J ; 198: 25-32, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29653644

RESUMO

AIM: The aim was to compare in a noninferiority trial the efficacy and safety of 2 contemporary drug-eluting stents (DESs): a novel, durable polymer-coated stent versus an established bioabsorbable polymer-coated stent. METHODS AND RESULTS: The BIONYX trial (ClinicalTrials.gov-no.NCT02508714) is an investigator-initiated, prospective, randomized, patient- and assessor-blinded, international, multicenter study in all-comer patients with all types of clinical syndromes and lesions who require percutaneous coronary interventions with DES. Patients at 7 study sites in the Netherlands, Belgium, and Israel were randomly assigned (1:1, stratified for gender and diabetes mellitus) to treatment with the novel, zotarolimus-eluting, durable polymer-coated Resolute Onyx stent that has a radiopaque, thin-strut, CoreWire stent platform versus the sirolimus-eluting, bioresorbable polymer-coated Orsiro stent (reference device) that has a very thin-strut, cobalt-chromium stent backbone. The primary end point is the 1-year incidence of the composite clinical end point target vessel failure consisting of cardiac death, target vessel-related myocardial infarction, or clinically indicated target vessel revascularization. A power calculation, assuming a target vessel failure rate of 6.0% (noninferiority margin 2.5%), revealed that 2,470 study patients would give the study 80% power (α level 5%), allowing for up to 3% loss to follow-up. The first patient was enrolled on October 7, 2015; on December 23, 2016, the last patient entered the study. CONCLUSIONS: BIONYX is a large-scale, prospective, randomized, international, multicenter trial comparing a novel DES with durable coating versus a reference DES with biodegradable coating in all-comers. The study is the first randomized assessment of the Resolute Onyx stent, which is an often-used DES outside the United States.


Assuntos
Implantes Absorvíveis , Estenose Coronária/cirurgia , Stents Farmacológicos , Everolimo/farmacologia , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Bélgica , Materiais Revestidos Biocompatíveis , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Internacionalidade , Israel , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Países Baixos , Segurança do Paciente/estatística & dados numéricos , Intervenção Coronária Percutânea/métodos , Polímeros , Estudos Prospectivos , Medição de Risco , Método Simples-Cego , Sirolimo/farmacologia , Estatísticas não Paramétricas , Taxa de Sobrevida , Resultado do Tratamento
15.
Acta Cardiol ; 71(2): 135-43, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-27090034

RESUMO

AIMS: Literature suggests a beneficial effect of percutaneous left atrial appendage occlusion (LAAO) to prevent thrombo-embolic events in patients with non-rheumatic atrial fibrillation (AF). We compared outcome of LAAO versus 'suboptimal standard' treatment in AF patients with high bleeding risk. METHODS AND RESULTS: Patients with sufficient follow-up data (n = 125) who underwent LAAO with the Amplatzer Cardiac Plug (ACP) were selected from the Belgian ACP database. AF patients who survived intracranial haemorrhage were recruited from the Leuven Neurosurgical Registry (LNR, n = 113). After propensity score adjustment, the outcome of both groups was compared for the combined end point (death, stroke, transient ischaemic attack, systemic emboli, and major bleeding event). The LAAO group did not differ from the LNR group for mean age and gender (74 ± 7 versus 75 ± 10 years, P = 0.29; female 39% versus 48%, P = 0.18). However, the CHA2DS2-VASc and HAS-BLED scores were both higher in the LAAO group (4.8 ± 1.7 versus 3.9 ± 1.7, P = 0.0001; 3.5 ± 1.4 versus 3.2 ± 1.4, P = 0.036). After propensity score adjustment, the risk for the primary end point was significantly higher for the LNR group (HR 2.012, 95% CI 1.113-3.638). CONCLUSION: LAAO with ACP seems to improve the combination of survival and the prevention of thrombo-embolic and major bleeding events in patients with atrial fibrillation and increased bleeding risk.


Assuntos
Fibrilação Atrial , Cateterismo Cardíaco , Hemorragia , Implantação de Prótese , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Anticoagulantes/administração & dosagem , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/terapia , Bélgica/epidemiologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Feminino , Hemorragia/etiologia , Hemorragia/prevenção & controle , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Implantação de Prótese/efeitos adversos , Implantação de Prótese/métodos , Sistema de Registros , Estudos Retrospectivos , Risco Ajustado , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 86(1): 128-35, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25676316

RESUMO

OBJECTIVES: We sought to provide a systematic review of reported cases of LAA closure device embolization by focusing on the two most commonly implanted devices: the Watchman (WM) device and the Amplatzer Cardiac Plug (ACP). METHODS: A comprehensive search of the Pubmed database was conducted until October 1, 2014. Studies were included if they described at least 1 case of embolization of the WM and/or the ACP. RESULTS: A total of 20 studies reporting 31 cases of device embolization were identified, including 13 cases with WM and 18 cases. The timing of embolization was described in 29 cases and was categorized as acute in 20 cases (65%) and late in 9 cases (30%). The anatomical location of embolized devices was reported in 21 cases: into the aorta in 9 cases, into the left ventricle (LV) in 9 cases and into the left atrial cavity in 3 cases. As compared to embolization into the aorta or the left atrial cavity, device embolization into the LV was associated with a higher rate of surgical retrieval (8/9 vs 2/12; 88% vs 17%, P = 0.0019). Major adverse events related to device embolization occurred in three patients (9.6%). CONCLUSIONS: LAA closure device embolization occurs mainly in the periprocedural period but late embolizations are not uncommon. Although embolization into the aorta or the left atrium can be successfully managed by percutaneous techniques in most cases, device embolization into the LV is associated with a higher rate of surgical retrieval, increasing thereby procedure-related morbidity.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Dispositivo para Oclusão Septal , Humanos , Ligadura
17.
Acta Cardiol ; 70(2): 133-40, 2015 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26148372

RESUMO

BACKGROUND: Percutaneous closure of atrial septal defect (ASD) and patent foramen ovale (PFO) are increasingly being performed. Effective closure rate depends on the anatomy of the interatrial septum and the device used, but its relationship with outcome is poorly described. This study aimed at evaluating: (1) effective ASD and PFO closure rate, (2) factors related with effective closure rate, and (3) factors related with mid-term outcome. METHODS: All patients who underwent percutaneous ASD or PFO closure at Jessa Hospital Hasselt between April 2002 and February 2014 were enrolled. Closure rate was evaluated using consecutive contrast echocardiography studies. Adverse events were defined as a composite of all-cause mortality, hospitalization for heart failure, atrial arrhythmias and thrombo-embolic event. RESULTS: One-hundred and two patients (52 +/- 12 y, 42% male, 75 PFO and 27 ASD) were included in the study. Moderate residual shunt was present in 6% and 10% 6 years after ASD and PFO closure, respectively. The presence of an aneurysmatic interatrial septum was associated with residual shunt after PFO closure (HR 0.57 95% CI 0.33-0.96; P=0.031). Pulmonary hypertension (HR 1.09 95% CI 1.01-1.17; P=0.017) and a history of atrial arrhythmias in ASD (HR 4.28 95% CI 1.06-17.40; P=0.046) and age at closure (HR 1.09 95% CI 1.02-1.16; P=0.012) in PFO patients were related with adverse events. The highest rate of adverse events was observed after placement of a Helex Septal Occluder. Amplatzer and Occlutech devices yielded higher effective closure rates. CONCLUSIONS: Effective closure rates were acceptable 6 years after ASD and PFO closure. The presence of an aneurysmatic septum is associated with residual shunting after PFO closure. Pulmonary hypertension in ASD and older age at closure in PFO are associated with adverse outcome. Adverse events are more frequent with the Helex occluder and effective closure rate depends on the device used.


Assuntos
Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/métodos , Forame Oval Patente/cirurgia , Átrios do Coração/cirurgia , Comunicação Interatrial/cirurgia , Bélgica/epidemiologia , Causas de Morte/tendências , Ecocardiografia , Feminino , Seguimentos , Forame Oval Patente/diagnóstico por imagem , Átrios do Coração/diagnóstico por imagem , Comunicação Interatrial/diagnóstico por imagem , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
18.
Artigo em Inglês | MEDLINE | ID: mdl-38789340

RESUMO

BACKGROUND: There are different definitions of periprocedural myocardial infarction (PPMI) both in terms of thresholds for cardiac biomarkers and the ancillary criteria for myocardial ischemia. Cardiac Troponin I (cTnI) and cardiac Troponin T (cTnT) are used interchangeably to diagnose PPMI. OBJECTIVES: This study evaluated the frequency of periprocedural myocardial injury and infarction as defined by the Society of Cardiovascular Angiography & Interventions (SCAI), the Academic Research Consortium-2 (ARC-2), and the 4th Universal definition of MI (4UDMI) stratified using cTnT versus cTnI, among patients with chronic coronary syndrome (CCS) and unstable angina. RESULTS: Among 830 patients, PPMI rates according to the SCAI, ARC2 and 4UDMI criteria were 4.34 %, 2.05 %, and 4.94 % respectively, with higher rates seen for all definitions when using cTnI versus cTnT (SCAI: 9.84 % vs. 1.91 %, p < 0.001; ARC 2: 3.15 % vs. 1.56 %, p = 0.136; and 4UDMI 5.91 % vs. 4.51 %, p = 0.391). Minor and major periprocedural myocardial injury was respectively observed in 58.31 % and 27.10 % of patients, with rates of both significantly higher when using cTnI versus cTnT (Minor: 69.29 % vs. 53.47 %, p < 0.001, Major: 49.21 % vs. 17.36 %, p < 0.001). CONCLUSIONS: Among patients with CCS and unstable angina, PPMIs defined by SCAI occurred more frequently when using cTnI as opposed to cTnT, whereas the type of troponin had no impact on the incidence of PPMIs according to the ARC-2 and 4UDMI.

19.
Acta Cardiol ; 68(3): 319-23, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23882879

RESUMO

Percutaneous transluminal coronary rotational atherectomy (PTCRA) is an established treatment forvery calcified and/or undilatable coronary lesions. In contrast to data from directional coronary atherectomy (DCA) procedures, coronary artery aneurysms (CAA) or pseudoaneurysms have not routinely been described as a complication after PTCRA. We present a case of a 74-year-old patient, with a major CAA, found on a routine control coronary angiogram 4 months after a PTCRA of LAD complicated by a coronary perforation. A conservative management guided by coronary CT angiography is proposed.


Assuntos
Falso Aneurisma/diagnóstico , Angina Pectoris/cirurgia , Aterectomia Coronária/efeitos adversos , Aneurisma Coronário/diagnóstico , Angiografia Coronária/métodos , Ecocardiografia/métodos , Tomografia Computadorizada por Raios X/métodos , Idoso , Falso Aneurisma/fisiopatologia , Aneurisma Coronário/fisiopatologia , Feminino , Seguimentos , Humanos , Complicações Pós-Operatórias , Fatores de Tempo
20.
Acta Cardiol ; 68(6): 551-8, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24579432

RESUMO

AIMS: The aim of the present study was to evaluate the procedural feasibility, the safety and the 1-year outcome following left atrial appendage (LAA) closure using the Amplatzer cardiac plug (ACP) in Belgium. METHODS AND RESULTS: Data were prospectively collected among 90 consecutive patients, undergoing LAA closure with an ACP in 7 Belgian centres between June 2009 and September 2012. The patients (56 males, 74 +/- 8 years) were at high risk for stroke (CHA2DS2-VASc = 4.4 +/- 1.8) and bleeding (HAS-BLED = 3.3 +/- 1.3).Technical success was obtained in all but one patient and procedural success was 95%. Procedural major adverse events (MAE) were 3 tamponades resulting in death in one case. Minor complications were 3 insignificant pericardial effusions, 2 transient myocardial ischaemia due to air embolism and 1 femoral pseudoaneurysm. At 1-y follow-up, there were 4 deaths, 2 minor strokes, 1 tamponade and 1 myocardial infarction. Overall survival was 94% and freedom from MAE was 88%. In our population, the expected annual stroke risk according to the CHA2DS2-VASc score was 5.08%, while the observed stroke rate was 2.14%/year. CONCLUSIONS: The Belgian registry shows that LAA closure using the ACP device is feasible and safe. At 1-y follow-up, the observed stroke rate was 2.14%/year, less than predicted by the CHA2DS2-VASc score. Longer follow-up is needed to evaluate the long-term safety and its efficacy in reducing stroke.


Assuntos
Apêndice Atrial/cirurgia , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/métodos , Procedimentos Cirúrgicos Cardíacos/instrumentação , Sistema de Registros , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral/prevenção & controle , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/complicações , Fibrilação Atrial/fisiopatologia , Bélgica/epidemiologia , Cineangiografia , Ecocardiografia Transesofagiana , Feminino , Seguimentos , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA