RESUMO
INTRODUCTION: Inappropriate ventilator settings, non-adherence to a lung-protective ventilation strategy, and inadequate patient monitoring during mechanical ventilation can potentially expose critically ill children to additional risks. We set out to improve team theoretical knowledge and practical skills regarding pediatric mechanical ventilation and to increase compliance with treatment goals. METHODS: An educational initiative was conducted from August 2019 to July 2021 in a neonatal and pediatric intensive care unit of the University Children's Hospital, Hamburg-Eppendorf, Germany. We tested baseline theoretical knowledge using a multiple choice theory test (TT) and practical skills using a practical skill test (PST), consisting of four sequential Objective Structured Clinical Examinations of physicians and nurses. We then implemented an educational bundle that included video self-training, checklists, pocket cards, and reevaluated team performance. Ventilators and monitor settings were randomly checked in all ventilated patients. We used a process control chart and a mixed-effects model to analyze the primary outcome. RESULTS: A total of 47 nurses and 20 physicians underwent assessment both before and after the implementation of the initiative using TT. Additionally, 34 nurses and 20 physicians were evaluated using the PST component of the initiative. The findings revealed a significant improvement in staff performance for both TT and PST (TT: 80% [confidence interval (CI): 77.2-82.9] vs. 86% [CI: 83.1-88.0]; PST: 73% [CI: 69.7-75.5] vs. 95% [CI: 93.8-97.1]). Additionally, there was a notable increase in self-confidence among participants, and compliance with mechanical ventilation treatment goals also saw a substantial rise, increasing from 87.8% to 94.5%. DISCUSSION: Implementing a pediatric mechanical ventilation education bundle improved theoretical knowledge and practical skills among interprofessional pediatric intensive care staff and increased treatment goal compliance in ventilated children.
Assuntos
Cardiologia , Respiração Artificial , Recém-Nascido , Humanos , Criança , Projetos Piloto , Escolaridade , Unidades de Terapia Intensiva PediátricaRESUMO
OBJECTIVES: The prediction of patient responses to potentially painful stimuli remains a challenge in PICUs. We investigated the ability of the paintracker analgesia monitor (Dolosys GmbH, Berlin, Germany) measuring the nociceptive flexion reflex threshold, the cerebral sedation monitor bispectral index (Medtronic, Dublin, Ireland), the COMFORT Behavior, and the modified Face, Legs, Activity, Cry, Consolability Scale scores to predict patient responses following a noxious stimulus. DESIGN: Single-center prospective exploratory observational study. SETTING: Fourteen-bed multidisciplinary PICU at the University Children's Hospital, University Medical Center Hamburg Eppendorf, Germany. PATIENTS: Children on mechanical ventilation receiving analgesic and sedative medications. INTERVENTIONS: Noxious stimulation by way of endotracheal suctioning. MEASUREMENTS AND MAIN RESULTS: Two independent observers assessed modified Face, Legs, Activity, Cry, Consolability and COMFORT Behavior Scales scores during noxious stimulation (n = 59) in 26 patients. Vital signs were recorded immediately before and during noxious stimulation; bispectral index and nociceptive flexion reflex threshold were recorded continuously. Mean prestimulation bispectral index (55.5; CI, 44.2-66.9 vs 39.9; CI, 33.1-46.8; p = 0.007), and COMFORT Behavior values (9.5; CI, 9.2-13.2 vs 7.5; CI, 6.7-8.5; p = 0.023) were significantly higher in observations with a response than in those without a response. Prediction probability (Pk) values for patient responses were high when the bispectral index was used (Pk = 0.85) but only fair when the nociceptive flexion reflex threshold (Pk = 0.69) or COMFORT Behavior Scale score (Pk = 0.73) was used. A logistic mixed-effects model confirmed the bispectral index as a significant potential predictor of patient response (p = 0.007). CONCLUSIONS: In our sample of ventilated children in the PICU, bispectral index and nociceptive flexion reflex threshold provided good and fair prediction accuracy for patient responses to endotracheal suctioning.
Assuntos
Eletroencefalografia , Nociceptividade , Criança , Humanos , Hipnóticos e Sedativos/farmacologia , Estudos Prospectivos , ReflexoRESUMO
IAH after LTX can impair perfusion and threaten graft viability. This study aimed to assess the feasibility of longitudinal IAP measurements as an IAH screening method in children after LTX. A cohort of 23 children with a mean age (range) 3.1 (3 months-14 years) who underwent LTX between May 2017 and February 2018 were evaluated retrospectively. Longitudinal IAP measurements were compared to bedside Doppler US monitoring data. In total, 425 IAP measurements and 257 US examinations were performed. The mean ± SD (range) time expenditure for IAP measurement was 1.9 ± 0.4 (0.5-3.2) minutes. The mean post-operative IAP was 7.9 ± 3.6 (1-25) mm Hg. IAH (IAP ≥ 10 mm Hg) was noted in 102 (24%) of 257 measurements. Agitation had a significant impact on IAP (estimate: 9.3 mm Hg, CI: 6.72-11.97, P < .01). In patients with TAC, IAP was increased (6.7 ± 2.1 vs 8.7 ± 3.1 mm Hg, P = .02) while peak portal venous velocities decreased (38 ± 27 vs 26 ± 22 cm/s, P = .03) after patch reduction. An abdominal compartment syndrome with severely impaired vascular flow was noted in one patient. Episodes of elevated IAP were noted in a large proportion of patients, underscoring the need for IAP monitoring in pediatric liver transplant recipients. The safety and low time expenditure associated with IAP measurement could be included easily into standard nursing procedures for these patients.