Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiology ; 298(2): E81-E87, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-32870139

RESUMO

Background The role and performance of chest CT in the diagnosis of the coronavirus disease 2019 (COVID-19) pandemic remains under active investigation. Purpose To evaluate the French national experience using chest CT for COVID-19, results of chest CT and reverse transcription polymerase chain reaction (RT-PCR) assays were compared together and with the final discharge diagnosis used as the reference standard. Materials and Methods A structured CT scan survey (NCT04339686) was sent to 26 hospital radiology departments in France between March 2, 2020, and April 24, 2020. These dates correspond to the peak of the national COVID-19 epidemic. Radiology departments were selected to reflect the estimated geographic prevalence heterogeneities of the epidemic. All symptomatic patients suspected of having COVID-19 pneumonia who underwent both initial chest CT and at least one RT-PCR test within 48 hours were included. The final discharge diagnosis, based on multiparametric items, was recorded. Data for each center were prospectively collected and gathered each week. Test efficacy was determined by using the Mann-Whitney test, Student t test, χ2 test, and Pearson correlation coefficient. P < .05 indicated a significant difference. Results Twenty-six of 26 hospital radiology departments responded to the survey, with 7500 patients entered; 2652 did not have RT-PCR test results or had unknown or excess delay between the RT-PCR test and CT. After exclusions, 4824 patients (mean age, 64 years ± 19 [standard deviation], 2669 male) were included. With final diagnosis as the reference, 2564 of the 4824 patients had COVID-19 (53%). Sensitivity, specificity, negative predictive value, and positive predictive value of chest CT in the diagnosis of COVID-19 were 2319 of 2564 (90%; 95% CI: 89, 91), 2056 of 2260 (91%; 95% CI: 91, 92), 2056 of 2300 (89%; 95% CI: 87, 90), and 2319 of 2524 (92%; 95% CI: 91, 93), respectively. There was no significant difference for chest CT efficacy among the 26 geographically separate sites, each with varying amounts of disease prevalence. Conclusion Use of chest CT for the initial diagnosis and triage of patients suspected of having coronavirus disease 2019 was successful. © RSNA, 2021 Online supplemental material is available for this article.


Assuntos
COVID-19/diagnóstico por imagem , COVID-19/epidemiologia , Radiografia Torácica/métodos , Tomografia Computadorizada por Raios X/métodos , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , SARS-CoV-2 , Sensibilidade e Especificidade , Adulto Jovem
2.
JTCVS Open ; 16: 263-275, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204721

RESUMO

Objectives: Secondary functional tricuspid regurgitation (FTR) management remains controversial mainly due to the lack of knowledge in its pathogenesis and the difficulties to measure the actual dimensions of tricuspid annulus (TA) with current imaging methods. Using a novel method based on multiphase cardiac computed tomography (CT) scan acquisition to accurately analyze the right atrioventricular junction size, we sought to explore modifications of TA morphometry and dynamics in secondary FTR. Methods: Echocardiographic and cardiac CT studies were obtained from 21 patients with severe mitral regurgitation (MR group) and 21 patients with dilated cardiomyopathy (DCMP group). Using an in-house software, a 3-dimensiontal (3D) semiautomated delineation of the TA perimeter was assessed. Modifications of diameters, 2-dimensional/3D areas and perimeters were analyzed through time. These 2 groups of patients were compared with 30 healthy subjects, considering the presence of a significant (≥2+) versus nonsignificant (<2+) FTR in each group. Results: Maximum TA 3D areas were 7.0 ± 1.2 cm2/m2 in healthy subjects at mid-to-late diastole and were smaller than in the MR group (9.8 ± 2.1 cm2/m2, P < .001) and the DCMP group (9.2 ± 3.0 cm2/m2, P < .001). In the MR group, patients with FTR <2+ had also larger TA areas and diameters than healthy patients (P < .01 for all 3D/2-dimensional parameters). TA shape was more circular only in the DCMP group with FTR ≥2+ compared with other patients (P < .05 for eccentricity). In multivariate analysis, both RA area (P < .001) and RV volume (P = .002) were independently related to TA dilatation. Conclusions: Based on multiphase CT image analyses, TA dilatation was directly related to RV and RA enlargement. Patients with severe mitral myxomatous disease and nondysfunctional tricuspid valve had yet dilated TA, which questioned the current cut-off recommendation for concomitant tricuspid annuloplasty in this specific population.

3.
Cardiovasc Eng Technol ; 13(5): 699-711, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35167041

RESUMO

PURPOSE: To improve knowledge of the tricuspid valve and right atrioventricular junction (RAVJ) coupling, four-dimensional (4D) imaging is mandatory (3D + time). Based on multiphase cardiac-volume computed tomography (CT) and innovative 4D analysis, we proposed to assess dynamical features of tricuspid annulus (TA) in relation to the right ventricle (RV) and right atrial (RA) functions. METHODS: Cardiac-volume CT data sets through time were obtained in 30 healthy patients (Male 57%, mean age 57 ± 11 years). Using an in-house software, 3D semi-automated delineation of 18 points around TA perimeter were defined through 10 cardiac phases within RR interval and used to calculate TA features such as 3D/2D areas, perimeters, 360°-diameters and vertical deformation. RV and RA inner contours were also delineated. Bi-dimensional parameters were compared with multiplanar reconstruction (MPR) measurements. RESULTS: TA was elliptical in horizontal projection with a maximal eccentricity index (EcImax) of 0.58 ± 0.12; and saddle-shaped in vertical projection with a horn nearby the antero-septal commissure. This feature remained throughout the cardiac cycle, but TA was more planar and less circular in late diastole (TA-height: 4.53 ± 1.06 mm, EcImax = 0.61 ± 0.14) when TA 3D area and perimeter reached a maximum of 7.05 ± 1.23 and 7.48 ± 0.93cm/m2, respectively. Correlations between minimal and maximal TA 3D areas and TA Projected 2D areas were excellent (r = 0.993 and r = 0.995, p < 0.001). TA 2D area measurements by MPR overestimated the projected values by 22 to 24%. Correlation between RV concentric strain and TA maximal diameter shortening was r = 0.452 (p = 0.01). CONCLUSIONS: Cardiac-volume CT improves physiological knowledge of the relationships between the RAVJ components in healthy subjects.


Assuntos
Ecocardiografia Tridimensional , Insuficiência da Valva Tricúspide , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Ecocardiografia Tridimensional/métodos , Voluntários Saudáveis , Tomografia Computadorizada Quadridimensional , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA