Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Magn Reson Med ; 92(5): 1822-1837, 2024 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-39072791

RESUMO

PURPOSE: There are many approaches to the quantitative BOLD (qBOLD) technique described in the literature, differing in pulse sequences, MRI parameters and data processing. Thus, in this review, we summarized the acquisition methods, approaches used for oxygenation quantification and clinical populations investigated. METHODS: Three databases were systematically searched (Medline, Embase, and Web of Science) for published research that used qBOLD methods for quantification of oxygen metabolism. Data extraction and synthesis were performed by one author and reviewed by a second author. RESULTS: A total of 93 relevant papers were identified. Acquisition strategies were summarized, and oxygenation parameters were found to have been investigated in many pathologies such as steno-occlusive diseases, stroke, glioma, and multiple sclerosis disease. CONCLUSION: A summary of qBOLD approaches for oxygenation measurements and applications could help researchers to identify good practice and provide objective information to inform the development of future consensus recommendations.


Assuntos
Imageamento por Ressonância Magnética , Oxigênio , Humanos , Imageamento por Ressonância Magnética/métodos , Oxigênio/metabolismo , Processamento de Imagem Assistida por Computador/métodos , Consumo de Oxigênio/fisiologia
2.
Magn Reson Med ; 88(1): 341-356, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35253936

RESUMO

PURPOSE: In chemical exchange saturation transfer imaging, saturation effects between - 2 to - 5 ppm (nuclear Overhauser effects, NOEs) have been shown to exhibit contrast in preclinical stroke models. Our previous work on NOEs in human stroke used an analysis model that combined NOEs and semisolid MT; however their combination might feasibly have reduced sensitivity to changes in NOEs. The aim of this study was to explore the information a 4-pool Bloch-McConnell model provides about the NOE contribution in ischemic stroke, contrasting that with an intentionally approximate 3-pool model. METHODS: MRI data from 12 patients presenting with ischemic stroke were retrospectively analyzed, as well as from six animals induced with an ischemic lesion. Two Bloch-McConnell models (4 pools, and a 3-pool approximation) were compared for their ability to distinguish pathological tissue in acute stroke. The association of NOEs with pH was also explored, using pH phantoms that mimic the intracellular environment of naïve mouse brain. RESULTS: The 4-pool measure of NOEs exhibited a different association with tissue outcome compared to 3-pool approximation in the ischemic core and in tissue that underwent delayed infarction. In the ischemic core, the 4-pool measure was elevated in patient white matter ( 1.20±0.20 ) and in animals ( 1.27±0.20 ). In the naïve brain pH phantoms, significant positive correlation between the NOE and pH was observed. CONCLUSION: Associations of NOEs with tissue pathology were found using the 4-pool metric that were not observed using the 3-pool approximation. The 4-pool model more adequately captured in vivo changes in NOEs and revealed trends depending on tissue pathology in stroke.


Assuntos
AVC Isquêmico , Acidente Vascular Cerebral , Animais , Humanos , Isquemia , Imageamento por Ressonância Magnética/métodos , Camundongos , Prótons , Estudos Retrospectivos , Acidente Vascular Cerebral/diagnóstico por imagem
3.
Neuroimage ; 202: 116106, 2019 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-31430532

RESUMO

Streamlined Quantitative BOLD (sqBOLD) is an MR technique that can non-invasively measure physiological parameters including Oxygen Extraction Fraction (OEF) and deoxygenated blood volume (DBV) in the brain. Current sqBOLD methodology rely on fitting a linear model to log-transformed data acquired using an Asymmetric Spin Echo (ASE) pulse sequence. In this paper, a non-linear model implemented in a Bayesian framework was used to fit physiological parameters to ASE data. This model makes use of the full range of available ASE data, and incorporates the signal contribution from venous blood, which was ignored in previous analyses. Simulated data are used to demonstrate the intrinsic difficulty in estimating OEF and DBV simultaneously, and the benefits of the proposed non-linear model are shown. In vivo data are used to show that this model improves parameter estimation when compared with literature values. The model and analysis framework can be extended in a number of ways, and can incorporate prior information from external sources, so it has the potential to further improve OEF estimation using sqBOLD.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/irrigação sanguínea , Modelos Neurológicos , Teorema de Bayes , Simulação por Computador , Humanos , Imageamento por Ressonância Magnética , Oxigênio/análise
4.
Neuroimage ; 187: 128-144, 2019 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-29277404

RESUMO

The ultimate goal of calibrated fMRI is the quantitative imaging of oxygen metabolism (CMRO2), and this has been the focus of numerous methods and approaches. However, one underappreciated aspect of this quest is that in the drive to measure CMRO2, many other physiological parameters of interest are often acquired along the way. This can significantly increase the value of the dataset, providing greater information that is clinically relevant, or detail that can disambiguate the cause of signal variations. This can also be somewhat of a double-edged sword: calibrated fMRI experiments combine multiple parameters into a physiological model that requires multiple steps, thereby providing more opportunity for error propagation and increasing the noise and error of the final derived values. As with all measurements, there is a trade-off between imaging time, spatial resolution, coverage, and accuracy. In this review, we provide a brief overview of the benefits and pitfalls of extracting multiparametric measurements of cerebral physiology through calibrated fMRI experiments.


Assuntos
Mapeamento Encefálico/métodos , Córtex Cerebral/diagnóstico por imagem , Córtex Cerebral/fisiologia , Imageamento por Ressonância Magnética/métodos , Doença de Alzheimer/diagnóstico por imagem , Doença de Alzheimer/fisiopatologia , Animais , Calibragem , Volume Sanguíneo Cerebral , Córtex Cerebral/irrigação sanguínea , Circulação Cerebrovascular , Humanos , Processamento de Imagem Assistida por Computador/métodos , Oxigênio/metabolismo , Consumo de Oxigênio
5.
Neuroimage ; 201: 116035, 2019 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-31326570

RESUMO

Quantitative BOLD (qBOLD) is a technique for mapping oxygen extraction fraction (OEF) and deoxygenated blood volume (DBV) in the human brain. Recent measurements using an asymmetric spin echo (ASE) based qBOLD approach produced estimates of DBV which were systematically higher than measurements from other techniques. In this study, we investigate two hypotheses for the origin of this DBV overestimation using simulations and consider the implications for experimental measurements. Investigations were performed by combining Monte Carlo simulations of extravascular signal with an analytical model of the intravascular signal. HYPOTHESIS 1: DBV overestimation is due to the presence of intravascular signal which is not accounted for in the analysis model. Intravascular signal was found to have a weak effect on qBOLD parameter estimates. HYPOTHESIS 2: DBV overestimation is due to the effects of diffusion which are not accounted for in the analysis model. The effect of diffusion on the extravascular signal was found to result in a vessel radius dependent variation in qBOLD parameter estimates. In particular, DBV overestimation peaks for vessels with radii from 20 to 30 µm and is OEF dependent. This results in the systematic underestimation of OEF. IMPLICATIONS: The impact on experimental qBOLD measurements was investigated by simulating a more physiologically realistic distribution of vessel sizes with a small number of discrete radii. Overestimation of DBV consistent with previous experiments was observed, which was also found to be OEF dependent. This results in the progressive underestimation of the measured OEF. Furthermore, the relationship between the measured OEF and the true OEF was found to be dependent on echo time and spin echo displacement time. The results of this study demonstrate the limitations of current ASE based qBOLD measurements and provide a foundation for the optimisation of future acquisition approaches.


Assuntos
Volume Sanguíneo Cerebral , Simulação por Computador , Imageamento por Ressonância Magnética , Oxigênio/sangue , Humanos
6.
Hum Brain Mapp ; 40(10): 2853-2866, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-30860660

RESUMO

Metabolic markers of baseline brain oxygenation and tissue perfusion have an important role to play in the early identification of ischaemic tissue in acute stroke. Although well established MRI techniques exist for mapping brain perfusion, quantitative imaging of brain oxygenation is poorly served. Streamlined-qBOLD (sqBOLD) is a recently developed technique for mapping oxygenation that is well suited to the challenge of investigating acute stroke. In this study a noninvasive serial imaging protocol was implemented, incorporating sqBOLD and arterial spin labelling to map blood oxygenation and perfusion, respectively. The utility of these parameters was investigated using imaging based definitions of tissue outcome (ischaemic core, infarct growth and contralateral tissue). Voxel wise analysis revealed significant differences between all tissue outcomes using pairwise comparisons for the transverse reversible relaxation rate (R 2 '), deoxygenated blood volume (DBV) and deoxyghaemoglobin concentration ([dHb]; p < 0.01 in all cases). At the patient level (n = 9), a significant difference was observed for [dHb] between ischaemic core and contralateral tissue. Furthermore, serial analysis at the patient level (n = 6) revealed significant changes in R 2 ' between the presentation and 1 week scans for both ischaemic core (p < 0.01) and infarct growth (p < 0.05). In conclusion, this study presents evidence supporting the potential of sqBOLD for imaging oxygenation in stroke.


Assuntos
Encéfalo/irrigação sanguínea , Encéfalo/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Neuroimagem/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Idoso , Idoso de 80 Anos ou mais , Imagem de Difusão por Ressonância Magnética/métodos , Feminino , Humanos , Masculino , Oxigênio/sangue , Acidente Vascular Cerebral/metabolismo
7.
NMR Biomed ; 32(3): e4061, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30657208

RESUMO

A better understanding of the coupling between changes in cerebral blood flow (CBF) and cerebral blood volume (CBV) is vital for furthering our understanding of the BOLD response. The aim of this study was to measure CBF-CBV coupling in different vascular compartments during neural activation. Three haemodynamic parameters were measured during a visual stimulus. Look-Locker flow-sensitive alternating inversion recovery was used to measure changes in CBF and arterial CBV (CBVa ) using sequence parameters optimized for each contrast. Changes in total CBV (CBVtot ) were measured using a gadolinium-based contrast agent technique. Haemodynamic changes were extracted from a region of interest based on voxels that were activated in the CBF experiments. The CBF-CBVtot coupling constant αtot was measured as 0.16 ± 0.14 and the CBF-CBVa coupling constant αa was measured as 0.65 ± 0.24. Using a two-compartment model of the vasculature (arterial and venous), the change in venous CBV (CBVv ) was predicted for an assumed value of baseline arterial and venous blood volume. These results will enhance the accuracy and reliability of applications that rely on models of the BOLD response, such as calibrated BOLD.


Assuntos
Encéfalo/irrigação sanguínea , Volume Sanguíneo Cerebral/fisiologia , Circulação Cerebrovascular/fisiologia , Adulto , Hemodinâmica , Humanos , Estimulação Luminosa , Processamento de Sinais Assistido por Computador , Fatores de Tempo , Adulto Jovem
8.
Neuroimage ; 169: 176-188, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-29253657

RESUMO

Calibrated functional magnetic resonance imaging (fMRI) is a method to independently measure the metabolic and hemodynamic contributions to the blood oxygenation level dependent (BOLD) signal. This technique typically requires the use of a respiratory challenge, such as hypercapnia or hyperoxia, to estimate the calibration constant, M. There has been a recent push to eliminate the gas challenge from the calibration procedure using asymmetric spin echo (ASE) based techniques. This study uses simulations to better understand spin echo (SE) and ASE signals, analytical modelling to characterize the signal evolution, and in vivo imaging to validate the modelling. Using simulations, it is shown how ASE imaging generally underestimates M and how this depends on several parameters of the acquisition, including echo time and ASE offset, as well as the vessel size. This underestimation is the result of imperfect SE refocusing due to diffusion of water through the extravascular environment surrounding the microvasculature. By empirically characterizing this SE attenuation as an exponential decay that increases with echo time, we have proposed a quadratic ASE biophysical signal model. This model allows for the characterization and compensation of the SE attenuation if SE and ASE signals are acquired at multiple echo times. This was tested in healthy subjects and was found to significantly increase the estimates of M across grey matter. These findings show promise for improved gas-free calibration and can be extended to other relaxation-based imaging studies of brain physiology.


Assuntos
Encéfalo/diagnóstico por imagem , Substância Cinzenta/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Microvasos/diagnóstico por imagem , Modelos Teóricos , Adulto , Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , Calibragem , Simulação por Computador , Substância Cinzenta/irrigação sanguínea , Substância Cinzenta/metabolismo , Humanos , Imageamento por Ressonância Magnética/normas , Consumo de Oxigênio/fisiologia
9.
Neuroimage ; 147: 79-88, 2017 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-27915118

RESUMO

Quantitative BOLD (qBOLD) is a non-invasive MR technique capable of producing quantitative measurements of the haemodynamic and metabolic properties of the brain. Here we propose a refinement of the qBOLD methodology, dubbed streamlined-qBOLD, in order to provide a clinically feasible method for mapping baseline brain oxygenation. In streamlined-qBOLD confounding signal contributions are minimised during data acquisition through the application of (i) a Fluid Attenuated Inversion Recovery (FLAIR) preparation to remove cerebral spinal fluid (CSF) signal contamination, (ii) a Gradient Echo Slice Excitation Profile Imaging (GESEPI) acquisition to reduce the effect of macroscopic magnetic field gradients and (iii) an Asymmetric Spin Echo (ASE) pulse sequence to directly measure the reversible transverse relaxation rate, R2'. Together these features simplify the application of the qBOLD model, improving the robustness of the resultant parametric maps. A theoretical optimisation framework was used to optimise acquisition parameters in relation to signal to noise ratio. In a healthy subject group (n = 7) apparent elevations in R2' caused by partial volumes of CSF were shown to be reduced with the application of CSF nulling. Significant decreases in R2' (p < 0.001) and deoxygenated blood volume (p < 0.01) were seen in cortical grey matter, across the group, with the application of CSF suppression. Quantitative baseline brain oxygenation parameter maps were calculated using qBOLD modelling and compared with literature values.


Assuntos
Química Encefálica , Mapeamento Encefálico/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Oxigênio/sangue , Adulto , Líquido Cefalorraquidiano/química , Circulação Cerebrovascular , Imagem Ecoplanar , Feminino , Voluntários Saudáveis , Humanos , Masculino , Consumo de Oxigênio , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Adulto Jovem
10.
Neuroimage ; 159: 214-223, 2017 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-28756241

RESUMO

Cerebrovascular reactivity mapping (CVR), using magnetic resonance imaging (MRI) and carbon dioxide as a stimulus, provides useful information on how cerebral blood vessels react under stress. This information has proven to be useful in the study of vascular disorders, dementia and healthy ageing. However, clinical adoption of this form of CVR mapping has been hindered by relatively long scan durations of 7-12 min. By replacing the conventional block presentation of carbon dioxide enriched air with a sinusoidally modulated stimulus, the aim of this study was to investigate whether more clinically acceptable scan durations are possible. Firstly, the conventional block protocol was compared with a sinusoidal protocol of the same duration of 7 min. Estimates of the magnitude of the CVR signal (CVR magnitude) were found to be in good agreement between the stimulus protocols, but estimates of the relative timing of the CVR response (CVR phase) were not. Secondly, data from the sinusoidal protocol was reanalysed using decreasing amounts of data in the range 1-6 min. The CVR magnitude was found to tolerate this reduction in scan duration better than CVR phase. However, these analyses indicate that scan durations in the range of 3-5 min produce robust data.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/irrigação sanguínea , Imageamento por Ressonância Magnética/métodos , Circulação Cerebrovascular , Humanos , Hipercapnia
11.
Neuroimage ; 135: 253-60, 2016 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-27150229

RESUMO

The reversible transverse relaxation rate, R2', is sensitive to the deoxyhaemoglobin content of brain tissue, enabling information about the oxygen extraction fraction to be obtained. However, R2' is also sensitive to macroscopic magnetic field gradients, particularly at air-tissue interfaces where a large susceptibility difference is present. It is important that this latter effect is minimised in order to produce meaningful estimates of blood oxygenation. Therefore, the aim of this study was to implement a technique to prospectively correct for the effect of susceptibility induced magnetic field gradients on R2' weighted data. This was achieved by combining the Gradient-Echo Slice Excitation Profile Imaging (GESEPI) technique with an Asymmetric Spin Echo (ASE) pulse sequence. The main advantages of this approach are (i) shorter acquisition times, since a separately acquired magnetic field map is not required and (ii) simpler analysis, since retrospective correction for the effects of magnetic field gradients in postprocessing is not required. In these experiments we show that with this newly developed technique it is possible to correct the majority of grey matter voxels for the expected distribution of through-slice magnetic field gradients to produce maps of R2' in a short scan duration.


Assuntos
Artefatos , Encéfalo/metabolismo , Hemoglobinas/metabolismo , Aumento da Imagem/métodos , Imageamento por Ressonância Magnética/métodos , Espectroscopia de Ressonância Magnética/métodos , Processamento de Sinais Assistido por Computador , Adulto , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Campos Magnéticos , Masculino , Imagem Molecular , Oximetria/métodos , Reprodutibilidade dos Testes , Espalhamento de Radiação , Sensibilidade e Especificidade , Adulto Jovem
12.
Neuroimage ; 129: 198-213, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26790354

RESUMO

Calibrated blood oxygenation level dependent (BOLD) imaging is a multimodal functional MRI technique designed to estimate changes in cerebral oxygen metabolism from measured changes in cerebral blood flow and the BOLD signal. This technique addresses fundamental ambiguities associated with quantitative BOLD signal analysis; however, its dependence on biophysical modeling creates uncertainty in the resulting oxygen metabolism estimates. In this work, we developed a Bayesian approach to estimating the oxygen metabolism response to a neural stimulus and used it to examine the uncertainty that arises in calibrated BOLD estimation due to the presence of unmeasured model parameters. We applied our approach to estimate the CMRO2 response to a visual task using the traditional hypercapnia calibration experiment as well as to estimate the metabolic response to both a visual task and hypercapnia using the measurement of baseline apparent R2' as a calibration technique. Further, in order to examine the effects of cerebral spinal fluid (CSF) signal contamination on the measurement of apparent R2', we examined the effects of measuring this parameter with and without CSF-nulling. We found that the two calibration techniques provided consistent estimates of the metabolic response on average, with a median R2'-based estimate of the metabolic response to CO2 of 1.4%, and R2'- and hypercapnia-calibrated estimates of the visual response of 27% and 24%, respectively. However, these estimates were sensitive to different sources of estimation uncertainty. The R2'-calibrated estimate was highly sensitive to CSF contamination and to uncertainty in unmeasured model parameters describing flow-volume coupling, capillary bed characteristics, and the iso-susceptibility saturation of blood. The hypercapnia-calibrated estimate was relatively insensitive to these parameters but highly sensitive to the assumed metabolic response to CO2.


Assuntos
Mapeamento Encefálico/métodos , Encéfalo/metabolismo , Oxigênio/metabolismo , Adulto , Teorema de Bayes , Encéfalo/irrigação sanguínea , Calibragem , Circulação Cerebrovascular/fisiologia , Humanos , Hipercapnia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Consumo de Oxigênio/fisiologia
13.
Neuroimage ; 129: 159-174, 2016 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-26801605

RESUMO

Several techniques have been proposed to estimate relative changes in cerebral metabolic rate of oxygen consumption (CMRO2) by exploiting combined BOLD fMRI and cerebral blood flow data in conjunction with hypercapnic or hyperoxic respiratory challenges. More recently, methods based on respiratory challenges that include both hypercapnia and hyperoxia have been developed to assess absolute CMRO2, an important parameter for understanding brain energetics. In this paper, we empirically optimize a previously presented "original calibration model" relating BOLD and blood flow signals specifically for the estimation of oxygen extraction fraction (OEF) and absolute CMRO2. To do so, we have created a set of synthetic BOLD signals using a detailed BOLD signal model to reproduce experiments incorporating hypercapnic and hyperoxic respiratory challenges at 3T. A wide range of physiological conditions was simulated by varying input parameter values (baseline cerebral blood volume (CBV0), baseline cerebral blood flow (CBF0), baseline oxygen extraction fraction (OEF0) and hematocrit (Hct)). From the optimization of the calibration model for estimation of OEF and practical considerations of hypercapnic and hyperoxic respiratory challenges, a new "simplified calibration model" is established which reduces the complexity of the original calibration model by substituting the standard parameters α and ß with a single parameter θ. The optimal value of θ is determined (θ=0.06) across a range of experimental respiratory challenges. The simplified calibration model gives estimates of OEF0 and absolute CMRO2 closer to the true values used to simulate the experimental data compared to those estimated using the original model incorporating literature values of α and ß. Finally, an error propagation analysis demonstrates the susceptibility of the original and simplified calibration models to measurement errors and potential violations in the underlying assumptions of isometabolism. We conclude that using the simplified calibration model results in a reduced bias in OEF0 estimates across a wide range of potential respiratory challenge experimental designs.


Assuntos
Encéfalo/metabolismo , Modelos Neurológicos , Consumo de Oxigênio/fisiologia , Encéfalo/irrigação sanguínea , Calibragem , Circulação Cerebrovascular/fisiologia , Simulação por Computador , Humanos , Hipercapnia/fisiopatologia , Hiperóxia/fisiopatologia , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Modelos Teóricos , Oxigênio/sangue
14.
Brain ; 138(Pt 1): 36-42, 2015 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-25564491

RESUMO

The original concept of the ischaemic penumbra suggested imaging of regional cerebral blood flow and metabolism would be required to identify tissue that may benefit from intervention. Amide proton transfer magnetic resonance imaging, a chemical exchange saturation transfer technique, has been used to derive cerebral intracellular pH in preclinical stroke models and has been proposed as a metabolic marker of ischaemic penumbra. In this proof of principle clinical study, we explored the potential of this pH-weighted magnetic resonance imaging technique at tissue-level. Detailed voxel-wise analysis was performed on data from a prospective cohort of 12 patients with acute ischaemic stroke. Voxels within ischaemic core had a more severe intracellular acidosis than hypoperfused tissue recruited to the final infarct (P < 0.0001), which in turn was more acidotic than hypoperfused tissue that survived (P < 0.0001). In addition, when confined to the grey matter perfusion deficit, intracellular pH (P < 0.0001), but not cerebral blood flow (P = 0.31), differed between tissue that infarcted and tissue that survived. Within the presenting apparent diffusion coefficient lesion, intracellular pH differed between tissue with early apparent diffusion lesion pseudonormalization and tissue with true radiographic recovery. These findings support the need for further investigation of pH-weighted imaging in patients with acute ischaemic stroke.


Assuntos
Isquemia Encefálica/complicações , Circulação Cerebrovascular/fisiologia , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/etiologia , Idoso de 80 Anos ou mais , Análise de Variância , Infarto Encefálico/etiologia , Estudos de Coortes , Imagem de Difusão por Ressonância Magnética , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade
15.
Neuroimage ; 122: 105-13, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-26254114

RESUMO

Recently a new class of calibrated blood oxygen level dependent (BOLD) functional magnetic resonance imaging (MRI) methods were introduced to quantitatively measure the baseline oxygen extraction fraction (OEF). These methods rely on two respiratory challenges and a mathematical model of the resultant changes in the BOLD functional MRI signal to estimate the OEF. However, this mathematical model does not include all of the effects that contribute to the BOLD signal, it relies on several physiological assumptions and it may be affected by intersubject physiological variability. The aim of this study was to investigate these sources of systematic error and their effect on estimating the OEF. This was achieved through simulation using a detailed model of the BOLD signal. Large ranges for intersubject variability in baseline physiological parameters such as haematocrit and cerebral blood volume were considered. Despite this the uncertainty in the relationship between the measured BOLD signals and the OEF was relatively low. Investigations of the physiological assumptions that underlie the mathematical model revealed that OEF measurements are likely to be overestimated if oxygen metabolism changes during hypercapnia or cerebral blood flow changes under hyperoxia. Hypoxic hypoxia was predicted to result in an underestimation of the OEF, whilst anaemic hypoxia was found to have only a minimal effect.


Assuntos
Artefatos , Mapeamento Encefálico/métodos , Encéfalo/fisiologia , Imageamento por Ressonância Magnética/métodos , Oxigênio/metabolismo , Encéfalo/irrigação sanguínea , Encéfalo/metabolismo , Simulação por Computador , Feminino , Humanos , Hipercapnia/fisiopatologia , Hiperóxia/fisiopatologia , Individualidade , Masculino , Modelos Neurológicos
16.
Neuroimage ; 104: 423-9, 2015 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-25451475

RESUMO

The calibrated BOLD (blood oxygen level dependent) technique was developed to quantify the BOLD signal in terms of changes in oxygen metabolism. In order to achieve this a calibration experiment must be performed, which typically requires a hypercapnic gas mixture to be administered to the participant. However, an emerging technique seeks to perform this calibration without administering gases using a refocussing based calibration. Whilst hypercapnia calibration seeks to emulate the physical removal of deoxyhaemoglobin from the blood, the aim of refocussing based calibration is to refocus the dephasing effect of deoxyhaemoglobin on the MR signal using a spin echo. However, it is not possible to refocus all of the effects that contribute to the BOLD signal and a scale factor is required to estimate the BOLD scaling parameter M. In this study the feasibility of a refocussing based calibration was investigated. The scale factor relating the refocussing calibration to M was predicted by simulations to be approximately linear and empirically measured to be 0.88±0.36 for the visual cortex and 0.93±0.32 for a grey matter region of interest (mean±standard deviation). Refocussing based calibration is a promising approach for greatly simplifying the calibrated BOLD methodology by eliminating the need for the subject to breathe special gas mixtures, and potentially provides the basis for a wider implementation of quantitative functional MRI.


Assuntos
Circulação Cerebrovascular/efeitos dos fármacos , Hipercapnia/metabolismo , Imageamento por Ressonância Magnética/métodos , Consumo de Oxigênio/efeitos dos fármacos , Oxigênio/metabolismo , Calibragem , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Modelos Lineares , Masculino
17.
Neuroimage ; 112: 189-196, 2015 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-25783207

RESUMO

Gas calibrated fMRI in its most common form uses hypercapnia in conjunction with the Davis model to quantify relative changes in the cerebral rate of oxygen consumption (CMRO2) in response to a functional stimulus. It is most commonly carried out at 3T but, as 7T research scanners are becoming more widespread and the majority of clinical scanners are still 1.5T systems, it is important to investigate whether the model used remains accurate across this range of field strengths. Ten subjects were scanned at 1.5, 3 and 7T whilst performing a bilateral finger-tapping task as part of a calibrated fMRI protocol, and the results were compared to a detailed signal model. Simulations predicted an increase in value and variation in the calibration parameter M with field strength. Two methods of defining experimental regions of interest (ROIs) were investigated, based on (a) BOLD signal and (b) BOLD responses within grey matter only. M values from the latter ROI were in closer agreement with theoretical predictions; however, reassuringly, ROI choice had less impact on CMRO2 than on M estimates. Relative changes in CMRO2 during motor tasks at 3 and 7T were in good agreement but were over-estimated at 1.5T as a result of the lower signal to noise ratio. This result is encouraging for future studies at 7T, but also highlights the impact of imaging and analysis choices (such as ASL sequence and ROI definition) on the calibration parameter M and on the calculation of CMRO2.


Assuntos
Imageamento por Ressonância Magnética/estatística & dados numéricos , Adulto , Química Encefálica , Calibragem , Simulação por Computador , Campos Eletromagnéticos , Feminino , Dedos , Substância Cinzenta/anatomia & histologia , Substância Cinzenta/metabolismo , Voluntários Saudáveis , Humanos , Hipercapnia/metabolismo , Cinética , Masculino , Movimento , Consumo de Oxigênio , Desempenho Psicomotor/fisiologia , Razão Sinal-Ruído
18.
NMR Biomed ; 28(5): 538-45, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25788020

RESUMO

Current functional MRI (fMRI) approaches assess underlying neuronal activity through monitoring the related local variations in cerebral blood oxygenation, blood volume and blood flow. This vascular response is likely to vary across brain regions and across individuals, depending on the composition of the local vascular bed and on the vascular capacity to dilate. The most widely used technique uses the blood oxygen level dependent (BOLD) fMRI signal, which arises from a complex combination of all of these factors. The model of handedness provides a case where one brain region (dominant motor cortex) is known to have a stronger BOLD response over another (non-dominant motor cortex) during hand motor task performance. We predict that this is accompanied by a higher vascular reactivity in the dominant motor cortex, when compared with the non-dominant motor cortex. Precise measurement of end-tidal CO2 and a novel sinusoidal CO2 respiratory challenge were combined with the high sensitivity and finer spatial resolution available for fMRI at 7 T to measure BOLD cerebrovascular reactivity (CVR) in eight healthy male participants. BOLD CVR was compared between the left (dominant) and right (non-dominant) primary motor cortices of right-handed adults. Hemispheric asymmetry in vascular reactivity was predicted and observed in the primary motor cortex (left CVR = 0.60 ± 0.15%/mm Hg; right CVR = 0.47 ± 0.08%/mm Hg; left CVR > right CVR, P = 0.04), the first reported evidence of such a vascular difference. These findings demonstrate a cerebral vascular asymmetry between the left and right primary motor cortex. The origin of this asymmetry largely arises from the contribution of large draining veins. This work has implications for future motor laterality studies that use BOLD, and it is also suggestive of a vascular plasticity in the human primary motor cortex.


Assuntos
Velocidade do Fluxo Sanguíneo/fisiologia , Circulação Cerebrovascular/fisiologia , Lateralidade Funcional/fisiologia , Córtex Motor/fisiologia , Movimento/fisiologia , Consumo de Oxigênio/fisiologia , Adulto , Potencial Evocado Motor/fisiologia , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
19.
J Affect Disord ; 362: 790-798, 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39019231

RESUMO

BACKGROUND: Cerebral mitochondrial and hemodynamic abnormalities have been implicated in Bipolar Disorder pathophysiology, likely contributing to neurometabolic vulnerability-leading to worsen clinical outcomes and mood instability. To investigate neurometabolic vulnerability in patients with BD, we combined multi-modal quantitative MRI assessment of cerebral oxygenation with acute administration of Methylene Blue, a neurometabolic/hemodynamic modulator acting on cerebral mitochondria. METHODS: Fifteen euthymic patients with chronic BD-type 1, and fifteen age/gender-matched healthy controls underwent two separate MRI sessions in a single-blinded randomized cross-over design, each after intravenous infusion of either MB (0.5 mg/kg) or placebo. MRI-based measures of Cerebral Blood Flow and Oxygen Extraction Fraction were integrated to compute Cerebral Metabolic Rate of Oxygen in Frontal Lobe, Anterior Cingulate, and Hippocampus-implicated in BD neurometabolic pathophysiology. Inter-daily variation in mood rating was used to assess mood instability. RESULTS: A decrease in global CBF and CMRO2 was observed after acutely administrating MB to all participants. Greater regional CMRO2 reductions were observed after MB, in patients compared to controls in FL (mean = -14.2 ± 19.5 % versus 2.3 ± 14.8 %), ACC (mean = -14.8 ± 23.7 % versus 2.4 ± 15.7 %). The effects on CMRO2 in those regions were primarily driven by patients with longer disease duration and higher mood instability. LIMITATIONS: Sample size; medications potentially impacting on response to MB. CONCLUSIONS: An altered neurometabolic response to MB, a mitochondrial/hemodynamic modulator, was observed in patients, supporting the hypothesis of vulnerability to neurometabolic stress in BD. Integrating quantitative imaging of cerebral oxygen metabolism with a mitochondrial-targeting pharmacological challenge could provide a novel biomarker of neurometabolic and cerebrovascular pathophysiology in BD.


Assuntos
Transtorno Bipolar , Imageamento por Ressonância Magnética , Azul de Metileno , Humanos , Transtorno Bipolar/tratamento farmacológico , Transtorno Bipolar/fisiopatologia , Transtorno Bipolar/metabolismo , Transtorno Bipolar/diagnóstico por imagem , Feminino , Masculino , Adulto , Azul de Metileno/farmacologia , Método Simples-Cego , Neuroimagem , Estudos Cross-Over , Pessoa de Meia-Idade , Circulação Cerebrovascular/efeitos dos fármacos , Circulação Cerebrovascular/fisiologia , Giro do Cíngulo/metabolismo , Giro do Cíngulo/diagnóstico por imagem , Giro do Cíngulo/fisiopatologia , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Encéfalo/efeitos dos fármacos , Encéfalo/fisiopatologia , Hipocampo/metabolismo , Hipocampo/efeitos dos fármacos , Hipocampo/diagnóstico por imagem , Mitocôndrias/metabolismo , Mitocôndrias/efeitos dos fármacos
20.
Neuroimage ; 72: 33-40, 2013 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-23370053

RESUMO

Hyperoxia is known to cause an increase in the blood oxygenation level dependent (BOLD) signal that is primarily localised to the venous vasculature. This contrast mechanism has been proposed as a way to measure venous cerebral blood volume (CBVv) without the need for more invasive contrast media. In the existing method the analysis modelled the data as a dynamic contrast agent experiment, with the assumption that the BOLD signal of tissue was dominated by intravascular signal. The effects on the accuracy of the method due to extravascular BOLD signal changes, as well as signal modulation by intersubject differences in baseline physiology, such as haematocrit and oxygen extraction fraction, have so far been unexplored. In this study the effect of extravascular signal and intersubject physiological variability was investigated by simulating the hyperoxia CBVv experiment using a detailed BOLD signal model. This analysis revealed substantial uncertainty in the measurement of CBVv using the existing analysis based on dynamic contrast agent experiments. Instead, the modelling showed a simple and direct relationship between the BOLD signal change and CBVv, and an alternative analysis method with much reduced uncertainty was proposed based on this finding. Both methods were tested experimentally, with the new method producing results that are consistent with the limited literature in this area.


Assuntos
Determinação do Volume Sanguíneo/métodos , Encéfalo/irrigação sanguínea , Hiperóxia/sangue , Imageamento por Ressonância Magnética/métodos , Adulto , Volume Sanguíneo , Circulação Cerebrovascular/fisiologia , Feminino , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Modelos Biológicos , Oxigênio/sangue
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA