Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
Intervalo de ano de publicação
1.
Diabetes Technol Ther ; 26(6): 383-393, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38277156

RESUMO

Background: To evaluate the long-term safety and effectiveness of the Omnipod® 5 Automated Insulin Delivery (AID) System in very young children with type 1 diabetes with up to 2 years of use. Methods: Following a 13-week single-arm, multicenter, pivotal trial that took place after 14 days of standard therapy data collection, participating children (2-5.9 years of age at study enrollment) were provided the option to continue use of the AID system in an extension phase. HbA1c was measured every 3 months, up to 15 months of total use, and continuous glucose monitor metrics were collected through the completion of the extension study (for up to 2 years). Results: Participants (N = 80) completed 18.2 [17.4, 23.4] (median [interquartile range]) total months of AID, inclusive of the 3-month pivotal trial. During the pivotal trial, HbA1c decreased from 7.4% ± 1.0% (57 ± 10.9 mmol/mol) to 6.9% ± 0.7% (52 ± 7.7 mmol/mol, P < 0.0001) and was maintained at 7.0% ± 0.7% (53 ± 7.7 mmol/mol) after 15 months total use (P < 0.0001 from baseline). Time in target range (70-180 mg/dL) increased from 57.2% ± 15.3% during standard therapy to 68.1% ± 9.0% during the pivotal trial (P < 0.0001) and was maintained at 67.2% ± 9.3% during the extension phase (P < 0.0001 from standard therapy). Participants spent a median 97.1% of time in Automated Mode during the extension phase, with one episode of severe hypoglycemia and one episode of diabetic ketoacidosis. Conclusion: This evaluation of the Omnipod 5 AID System indicates that long-term use can safely maintain improvements in glycemic outcomes with up to 2 years of use in very young children with type 1 diabetes. Clinical Trials Registration Number: NCT04476472.


Assuntos
Glicemia , Diabetes Mellitus Tipo 1 , Hemoglobinas Glicadas , Hipoglicemiantes , Sistemas de Infusão de Insulina , Insulina , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 1/sangue , Pré-Escolar , Insulina/administração & dosagem , Insulina/uso terapêutico , Feminino , Masculino , Glicemia/análise , Hipoglicemiantes/administração & dosagem , Hipoglicemiantes/uso terapêutico , Hemoglobinas Glicadas/análise , Hipoglicemia/prevenção & controle , Resultado do Tratamento , Controle Glicêmico/métodos , Automonitorização da Glicemia
2.
Diabetes Care ; 2024 Jul 23.
Artigo em Inglês | MEDLINE | ID: mdl-39042575

RESUMO

OBJECTIVE: To compare postprandial glucose excursions following a bolus with inhaled technosphere insulin (TI) or subcutaneous rapid-acting analog (RAA) insulin. RESEARCH DESIGN AND METHODS: A meal challenge was completed by 122 adults with type 1 diabetes who were using multiple daily injections (MDI), a nonautomated pump, or automated insulin delivery (AID) and who were randomized to bolus with their usual RAA insulin (n = 61) or TI (n = 61). RESULTS: The primary outcome, the treatment group difference in area under the curve for glucose >180 mg/dL over 2 h, was less with TI versus RAA (adjusted difference -12 mg/dL, 95% CI -22 to -2, P = 0.02). With TI, the glucose excursion was smaller (P = 0.01), peak glucose lower (P = 0.01), and time to peak glucose shorter (P = 0.006). Blood glucose <70 mg/dL occurred in one participant in each group. CONCLUSIONS: Postmeal glucose excursion was smaller with TI than with RAA insulin in a cohort that included both AID and MDI users.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA