Circulation ; 146(24): e334-e482, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36322642

RESUMO

AIM: The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS: A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. Structure: Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.


Assuntos
Doenças da Aorta , Doença da Válvula Aórtica Bicúspide , Cardiologia , Feminino , Humanos , Gravidez , American Heart Association , Doenças da Aorta/diagnóstico , Doenças da Aorta/terapia , Relatório de Pesquisa , Estados Unidos
2.
Radiology ; 286(3): 1052-1061, 2018 03.
Artigo em Inglês | MEDLINE | ID: mdl-29156147

RESUMO

Purpose To compare the diagnostic yield and complication rates of electromagnetic navigational bronchoscopic (ENB)-guided and computed tomography (CT)-guided percutaneous tissue sampling of lung nodules. Materials and Methods Retrospectively identified were 149 patients sampled percutaneously with CT guidance and 146 patients who underwent ENB with transbronchial biopsy of a lung lesion between 2013 and 2015. Clinical data, incidence of complications, and nodule pathologic analyses were assessed through electronic medical record review. Lung nodule characteristics were reviewed through direct image analysis. Molecular marker studies and pathologic analyses from surgical excision were reviewed when available. Multiple-variable logistic regression models were built to compare the diagnostic yield and complication rates for each method and for different patient and disease characteristics. Results CT-guided sampling was more likely to be diagnostic than ENB-guided biopsy (86.0% [129 of 150] vs 66.0% [99 of 150], respectively), and this difference remained significant even after adjustments were made for patient and nodule characteristics (P < .001). Age, American Society of Anesthesiologists class, emphysema grade, nodule size, and distance from pleura were not significant predictors of increased diagnostic yield. Intraprocedural time for physicians was significantly lower with CT-guided sampling (P < .001). Similar yield for molecular analyses was noted with the two approaches (ENB-guided sampling, 88.9% [32 of 36]; CT-guided sampling, 82.0% [41 of 50]). The two groups had similar rates of major complications (symptomatic hemorrhage, P > .999; pneumothorax requiring chest tube and/or admission, P = .417). Conclusion CT-guided transthoracic biopsy provided higher diagnostic yield in the assessment of peripheral pulmonary nodules than navigational bronchoscopy with a similar rate of clinically relevant complications. © RSNA, 2017 Online supplemental material is available for this article.


Assuntos
Biópsia/métodos , Broncoscopia/métodos , Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pulmão/diagnóstico por imagem , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Nódulos Pulmonares Múltiplos/patologia , Radiografia Torácica , Estudos Retrospectivos , Adulto Jovem
3.
J Vasc Interv Radiol ; 29(10): 1423-1428, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30174156

RESUMO

The aim of this brief report is to determine the safety and reliability of minimally invasive video-assisted thoracic surgery (VATS) resection without the aid of intraoperative fluoroscopy after computed tomography (CT)-guided microcoil localization of small peripheral pulmonary nodules. Twenty patients with peripheral lung nodules underwent percutaneous needle localization with a microcoil that was tagged back to the visceral pleural surface. Same-day VATS resection was performed without the use of intraoperative fluoroscopy. All 20 nodules were successfully localized in the CT procedure room, and all 20 nodules were resected with negative margins and no major complications.


Assuntos
Nódulos Pulmonares Múltiplos/diagnóstico por imagem , Nódulos Pulmonares Múltiplos/cirurgia , Nódulo Pulmonar Solitário/diagnóstico por imagem , Nódulo Pulmonar Solitário/cirurgia , Cirurgia Torácica Vídeoassistida , Tomografia Computadorizada por Raios X/instrumentação , Adolescente , Adulto , Idoso , Feminino , Humanos , Masculino , Margens de Excisão , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Cirurgia Torácica Vídeoassistida/efeitos adversos , Resultado do Tratamento , Adulto Jovem
5.
J Nucl Cardiol ; 23(5): 1102-1109, 2016 10.
Artigo em Inglês | MEDLINE | ID: mdl-26071114

RESUMO

INTRODUCTION: Although positron emission tomography PET-MR imaging is emerging into clinical practice, many aspects of this imaging technique such as attenuation correction have yet to be validated for myocardial imaging. Thus, it is uncertain whether PET-MR FDG images provide clinical information which is comparable to PET-CT FDG images. The study goal was to systematically compare relative myocardial FDG concentrations obtained from cardiac PET-MR images to those derived from same day PET-CT images. METHODS: Myocardial FDG images of 27 patients undergoing PET-CT imaging, followed by PET-MR imaging 42 ± 13 minutes later as part of a prospective oncology study were analyzed. Mean segmental standardized uptake measurements (SUVmean) were obtained in each of the 17 standard myocardial segments and normalized to the brightest segment. RESULTS: Normalized segmental SUVmean values did not differ significantly between the PET-MR and PET-CT images (mean difference 0.002, P = .826). The specific segment was a marginally significant predictor of the differences (P = .057), with the largest difference in the anteroseptal basal segment. CONCLUSIONS: PET-MR, vis-à-vis PET-CT, does not significantly raise segmental uptake relative to the brightest segment, suggesting that PET-MR can be used similarly to PET-CT for applications where relative uptake is important.


Assuntos
Técnicas de Imagem Cardíaca/métodos , Fluordesoxiglucose F18/farmacocinética , Coração/diagnóstico por imagem , Interpretação de Imagem Assistida por Computador/métodos , Miocárdio/metabolismo , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Adolescente , Adulto , Idoso , Simulação por Computador , Feminino , Humanos , Aumento da Imagem/métodos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares , Compostos Radiofarmacêuticos/farmacocinética , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
7.
Radiographics ; 35(2): 327-56, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25763721

RESUMO

Heart failure is recognized with increasing frequency worldwide and often progresses to an advanced refractory state. Although the reference standard for treatment of advanced heart failure remains cardiac transplantation, the increasing shortage of donor organs and the unsuitability of many patients for transplantation surgery has led to a search for alternative therapies. One such therapy is mechanical circulatory support, which helps relieve the load on the ventricle and thereby allows it to recover function. In addition, there is increasing evidence supporting the use of mechanical devices as a bridge to recovery in patients with acute refractory heart failure. In this article, the imaging evaluation of various commonly used short- and long-term cardiac assist devices is discussed, and their relevant mechanisms of action and physiology are described. Imaging, particularly computed tomography (CT), plays a crucial role in preoperative evaluation for assessment of candidacy for implantation of a left ventricular assist device (LVAD) or total artificial heart (TAH). Also, echocardiography and CT are indispensable in assessment of complications associated with cardiac devices. Complications commonly associated with short-term assist devices include bleeding and malpositioning, whereas long-term devices such as LVADs may be associated with infection, pump thrombosis, and cannula malfunction, as well as bleeding. CT is also commonly performed for preoperative planning before LVAD or TAH explantation, replacement of a device or one of its components, and cardiac transplantation. Online supplemental material is available for this article.


Assuntos
Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/cirurgia , Coração Auxiliar , Ventrículos do Coração , Humanos , Desenho de Prótese , Radiografia , Fatores de Tempo
8.
AJR Am J Roentgenol ; 203(4): 749-58, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25247940

RESUMO

OBJECTIVE: Transcatheter aortic valve implantation has emerged as a viable treatment alternative for patients with severe aortic stenosis who are not surgical candidates. Multidimensional (3D and 4D) MDCT angiography plays a critical role in the safety, success, and outcome of an institutional transcatheter aortic valve implantation program. CONCLUSION: Given the increasing therapeutic role of this innovative technique, an understanding of essential imaging concepts in its context is critical for appropriate image acquisition and interpretation.


Assuntos
Angiografia/métodos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Tomografia Computadorizada Multidetectores/métodos , Cirurgia Assistida por Computador/métodos , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Doença da Válvula Aórtica Bicúspide , Feminino , Humanos , Imageamento Tridimensional/métodos , Masculino , Resultado do Tratamento
9.
Radiographics ; 34(6): 1612-35, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25310420

RESUMO

Although 3-T magnetic resonance (MR) imaging is well established in neuroradiology and musculoskeletal imaging, it is in the nascent stages in cardiovascular imaging applications, and there is limited literature on this topic. The primary advantage of 3 T over 1.5 T is a higher signal-to-noise ratio (SNR), which can be used as such or traded off to improve spatial or temporal resolution and decrease acquisition time. However, the actual gain in SNR is limited by other factors and modifications in sequences adapted for use at 3 T. Higher resonance frequencies result in improved spectral resolution, which is beneficial for fat suppression and spectroscopy. The higher T1 values of tissues at 3 T aid in myocardial tagging, angiography, and perfusion and delayed-enhancement sequences. However, there are substantial challenges with 3-T cardiac MR imaging, including higher magnetic field and radiofrequency inhomogeneities and susceptibility effects, which diminish image quality. Off-resonance artifacts are particularly challenging, especially with steady-state free precession sequences. These artifacts can be managed by using higher-order shimming, frequency scouts, or low repetition times. B1 inhomogeneities can be managed by using radiofrequency shimming, multitransmit coils, or adiabatic pulses. Chemical shifts are also increased at 3 T. The higher radiofrequency results in higher radiofrequency deposition power and a higher specific absorption rate. MR angiography, dynamic first-pass perfusion sequences, myocardial tagging, and MR spectroscopy are more effective at 3 T, whereas delayed-enhancement, flow quantification, and black-blood sequences are comparable at 1.5 T and 3 T. Knowledge of the relevant physics helps in identifying artifacts and modifying sequences to optimize image quality. Online supplemental material is available for this article.


Assuntos
Cardiopatias/diagnóstico , Imageamento por Ressonância Magnética/métodos , Artefatos , Meios de Contraste , Humanos , Imageamento por Ressonância Magnética/instrumentação , Física , Razão Sinal-Ruído
11.
Int J Cardiovasc Imaging ; 40(3): 665-673, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38286950

RESUMO

Optimizing MRI aortic flow quantification is crucial for accurate assessment of valvular disease severity. In this study, we sought to evaluate the accuracy of a novel method of contouring systolic aortic forward flow in comparison to standard contouring methods at various aortic levels. The study included a cohort of patients with native aortic valve (AoV) disease and a small control group referred to cardiac MRI over a 1-year period. Inclusion criteria included aortic flow quantification at aortic valve and one additional level, and no or trace mitral regurgitation (MR) documented both by the MRI AND an echocardiogram done within a year. In addition to flow quantification with standard contouring (SC), a novel Selective Systolic Contouring (SSC) method was performed at aortic valve level, contouring the area demarcated by the AoV leaflets in systole. The bias in each technique's estimate of aortic forward flow was calculated as the mean difference between aortic forward flow and left ventricular stroke volume (LV SV). 98 patients (mean age 56, 71% male) were included: 33 with tricuspid and 65 with congenitally abnormal (bicuspid or unicuspid) AoV. All methods tended to underestimate aortic forward flow, but the bias was smallest with the SSC method (p < 0.001). Therefore, SSC yielded the lowest estimates of mitral regurgitant volume (4.8 ml) and regurgitant fraction (3.9%) (p < 0.05). SSC at AoV level better approximates LV SV in our cohort, and may provide more accurate quantitative assessment of both aortic and mitral valve function.


Assuntos
Valvopatia Aórtica , Insuficiência da Valva Mitral , Humanos , Masculino , Pessoa de Meia-Idade , Feminino , Valor Preditivo dos Testes , Imageamento por Ressonância Magnética/métodos , Insuficiência da Valva Mitral/diagnóstico por imagem , Volume Sistólico , Valva Aórtica/diagnóstico por imagem
12.
AJR Am J Roentgenol ; 201(5): 971-6, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24147466

RESUMO

OBJECTIVE: The purpose of this study was to compare high-pitch ECG-synchronized pulmonary CT angiography (CTA) with standard pulmonary CTA with regard to radiation dose and image quality in patients with suspected pulmonary embolism. SUBJECTS AND METHODS: This prospective study was approved by the institutional review board, and participants provided informed consent. Patients with suspected pulmonary embolism (60% women; mean age, 57 ± 14 years) were randomized to undergo high-pitch ECG-synchronized pulmonary CTA (n = 26) or standard pulmonary CTA (n = 21). Two independent readers assessed subjective image quality of pulmonary arteries, cardiovascular structures, and pulmonary parenchyma. Signal intensity (SI) was measured in one segmental and three central pulmonary arteries. RESULTS: High-pitch ECG-synchronized pulmonary CTA showed higher SI (p < 0.001) for pulmonary arteries. Image quality scores indicated improvement in assessment of cardio-vascular structures (p < 0.001), minimization of motion of central (p < 0.001) pulmonary arteries, and an increase in pulmonary arterial enhancement (p = 0.01) with high-pitch ECG-synchronized pulmonary CTA. Image quality scores for lung assessment were higher for standard pulmonary CTA (p < 0.001). The amount of contrast agent administered was similar between techniques (p = 0.86). Radiation dose was lower for high-pitch ECG-synchronized pulmonary CTA (p < 0.001). CONCLUSION: High-pitch ECG-synchronized pulmonary CTA provides higher pulmonary arterial SI, decreased motion of central pulmonary arteries, and improved assessment of cardiovascular structures with similar contrast dose and lower radiation compared with standard pulmonary CTA.


Assuntos
Angiografia/métodos , Técnicas de Imagem de Sincronização Cardíaca , Embolia Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador
13.
J Am Coll Radiol ; 20(11S): S501-S512, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-38040467

RESUMO

This document discusses preprocedural planning for transcatheter aortic valve replacement, evaluating the imaging modalities used in initial imaging for preprocedure planning under two variants 1) Preintervention planning for transcatheter aortic valve replacement: assessment of aortic root; and 2) Preintervention planning for transcatheter aortic valve replacement: assessment of supravalvular aorta and vascular access. US echocardiography transesophageal, MRI heart function and morphology without and with IV contrast, MRI heart function and morphology without IV contrast and CT heart function and morphology with IV contrast are usually appropriate for assessment of aortic root. CTA chest with IV contrast, CTA abdomen and pelvis with IV contrast, CTA chest abdomen pelvis with IV contrast are usually appropriate for assessment of supravalvular aorta and vascular access. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Substituição da Valva Aórtica Transcateter , Humanos , Imageamento por Ressonância Magnética , Sociedades Médicas , Tomografia Computadorizada por Raios X/métodos , Estados Unidos
14.
J Am Coll Radiol ; 20(11S): S351-S381, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-38040460

RESUMO

Pediatric heart disease is a large and diverse field with an overall prevalence estimated at 6 to 13 per 1,000 live births. This document discusses appropriateness of advanced imaging for a broad range of variants. Diseases covered include tetralogy of Fallot, transposition of great arteries, congenital or acquired pediatric coronary artery abnormality, single ventricle, aortopathy, anomalous pulmonary venous return, aortopathy and aortic coarctation, with indications for advanced imaging spanning the entire natural history of the disease in children and adults, including initial diagnosis, treatment planning, treatment monitoring, and early detection of complications. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where peer reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Doença da Artéria Coronariana , Cardiopatias , Adulto , Criança , Humanos , Diagnóstico Diferencial , Diagnóstico por Imagem/métodos , Sociedades Médicas , Estados Unidos
15.
J Thorac Cardiovasc Surg ; 166(5): e182-e331, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37389507

RESUMO

AIM: The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS: A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. STRUCTURE: Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.


Assuntos
Doenças da Aorta , Doença da Válvula Aórtica Bicúspide , Cardiologia , Feminino , Gravidez , Estados Unidos , Humanos , American Heart Association , Doenças da Aorta/diagnóstico , Doenças da Aorta/terapia , Aorta
16.
AJR Am J Roentgenol ; 198(4): 931-8, 2012 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-22451563

RESUMO

OBJECTIVE: We sought to compare image quality, contrast enhancement, and radiation dose in patients undergoing ECG-triggered high-pitch helical CT or non-ECG-synchronized helical CT of the thoracoabdominal aorta. MATERIALS AND METHODS: We retrospectively assessed data from 101 consecutive patients (81 men, 20 women; mean age, 71 ± 11 [SD] years) undergoing clinically indicated CT angiography (CTA) of the thoracoabdominal aorta on a dual-source scanner using either the ECG-triggered high-pitch helical mode (group 1, n = 52) or non-ECG-synchronized standard-pitch helical mode (group 2, n = 49) during the arterial phase. Two independent readers assessed image quality, noise, and contrast enhancement throughout the thoracoabdominal aorta. Scanner-reported dose-length product values were used to estimate effective dose values. RESULTS: Image quality at the root-proximal ascending level was higher in group 1 (mean ± SD, 2.81 ± 0.40) than in group 2 (1.22 ± 0.47; p < 0.0001), with similar quality for both groups noted at other levels. Group 1 scans displayed higher image noise at all levels. The groups received a similar volume of contrast material (p = 0.77), and similar percentages of cases with acceptable contrast enhancement (> 250 HU) were noted in the two groups. The estimated radiation burden was significantly lower in group 1 (mean ± SD, 5.4 ± 1.8 mSv) than in group 2 (14.4 ± 5.1 mSv; p < 0.0001). CONCLUSION: Imaging of the thoracoabdominal aorta with ECG-triggered high-pitch CTA provides higher quality images of the aortic root and ascending aorta with sufficient contrast enhancement and decreased estimated radiation dose compared with non-ECG-synchronized standard-pitch helical CT.


Assuntos
Angiografia/métodos , Doenças da Aorta/diagnóstico por imagem , Técnicas de Imagem de Sincronização Cardíaca/métodos , Tomografia Computadorizada Espiral/métodos , Idoso , Meios de Contraste , Eletrocardiografia , Feminino , Humanos , Iohexol/análogos & derivados , Masculino , Doses de Radiação , Estudos Retrospectivos
17.
Circ Cardiovasc Imaging ; 15(7): e014283, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35861978

RESUMO

Cardiac magnetic resonance imaging plays a central role among multimodality imaging modalities in the assessment, diagnosis, and surveillance of pericardial diseases. Clinicians and imagers should have a foundational understanding of the utilities, advantages, and limitations of cardiac magnetic resonance imaging and how they integrate with other diagnostic tools involved in the evaluation and management of pericardial diseases. This review aims to outline the contemporary magnetic resonance imaging sequences used to evaluate the pericardium, followed by exploring the main clinical applications of magnetic resonance imaging for identifying pericardial inflammation, constriction, and effusion.


Assuntos
Cardiopatias , Derrame Pericárdico , Pericardite Constritiva , Cardiopatias/diagnóstico por imagem , Cardiopatias/terapia , Humanos , Imageamento por Ressonância Magnética/métodos , Imagem Multimodal , Derrame Pericárdico/diagnóstico por imagem , Derrame Pericárdico/patologia , Pericardite Constritiva/diagnóstico , Pericárdio/diagnóstico por imagem , Pericárdio/patologia
18.
J Am Coll Radiol ; 19(5S): S37-S52, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35550804

RESUMO

Dyspnea is the symptom of perceived breathing discomfort and is commonly encountered in a variety of clinical settings. Cardiac etiologies of dyspnea are an important consideration; among these, valvular heart disease (Variant 1), arrhythmia (Variant 2), and pericardial disease (Variant 3) are reviewed in this document. Imaging plays an important role in the clinical assessment of these suspected abnormalities, with usually appropriate procedures including resting transthoracic echocardiography in all three variants, radiography for Variants 1 and 3, MRI heart function and morphology in Variants 2 and 3, and CT heart function and morphology with intravenous contrast for Variant 3. The American College of Radiology Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision include an extensive analysis of current medical literature from peer reviewed journals and the application of well-established methodologies (RAND/UCLA Appropriateness Method and Grading of Recommendations Assessment, Development, and Evaluation or GRADE) to rate the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances where evidence is lacking or equivocal, expert opinion may supplement the available evidence to recommend imaging or treatment.


Assuntos
Cardiopatias , Sociedades Médicas , Dispneia/diagnóstico por imagem , Dispneia/etiologia , Cardiopatias/complicações , Humanos , Isquemia , Tomografia Computadorizada por Raios X/efeitos adversos , Estados Unidos
19.
J Am Coll Radiol ; 19(11S): S488-S501, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36436972

RESUMO

Pulmonary embolism (PE) remains a common and important clinical condition that cannot be accurately diagnosed on the basis of signs, symptoms, and history alone. The diagnosis of PE has been facilitated by technical advancements and multidetector CT pulmonary angiography, which is the major diagnostic modality currently used. Ventilation and perfusion scans remain largely accurate and useful in certain settings. MR angiography can be useful in some clinical scenarios and lower-extremity ultrasound can substitute by demonstrating deep vein thrombosis; however, if negative, further studies to exclude PE are indicated. In all cases, correlation with the clinical status, particularly with risk factors, improves not only the accuracy of diagnostic imaging but also overall utilization. Other diagnostic tests have limited roles. The ACR Appropriateness Criteria are evidence-based guidelines for specific clinical conditions that are reviewed annually by a multidisciplinary expert panel. The guideline development and revision process support the systematic analysis of the medical literature from peer-reviewed journals. Established methodology principles such as Grading of Recommendations Assessment, Development, and Evaluation or GRADE are adapted to evaluate the evidence. The RAND/UCLA Appropriateness Method User Manual provides the methodology to determine the appropriateness of imaging and treatment procedures for specific clinical scenarios. In those instances in which peer-reviewed literature is lacking or equivocal, experts may be the primary evidentiary source available to formulate a recommendation.


Assuntos
Embolia Pulmonar , Sociedades Médicas , Humanos , Medicina Baseada em Evidências , Embolia Pulmonar/diagnóstico por imagem , Extremidade Inferior , Fatores de Risco
20.
J Am Coll Cardiol ; 80(24): e223-e393, 2022 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-36334952

RESUMO

AIM: The "2022 ACC/AHA Guideline for the Diagnosis and Management of Aortic Disease" provides recommendations to guide clinicians in the diagnosis, genetic evaluation and family screening, medical therapy, endovascular and surgical treatment, and long-term surveillance of patients with aortic disease across its multiple clinical presentation subsets (ie, asymptomatic, stable symptomatic, and acute aortic syndromes). METHODS: A comprehensive literature search was conducted from January 2021 to April 2021, encompassing studies, reviews, and other evidence conducted on human subjects that were published in English from PubMed, EMBASE, the Cochrane Library, CINHL Complete, and other selected databases relevant to this guideline. Additional relevant studies, published through June 2022 during the guideline writing process, were also considered by the writing committee, where appropriate. STRUCTURE: Recommendations from previously published AHA/ACC guidelines on thoracic aortic disease, peripheral artery disease, and bicuspid aortic valve disease have been updated with new evidence to guide clinicians. In addition, new recommendations addressing comprehensive care for patients with aortic disease have been developed. There is added emphasis on the role of shared decision making, especially in the management of patients with aortic disease both before and during pregnancy. The is also an increased emphasis on the importance of institutional interventional volume and multidisciplinary aortic team expertise in the care of patients with aortic disease.


Assuntos
American Heart Association , Doenças da Aorta , Estados Unidos , Humanos , Universidades , Doenças da Aorta/diagnóstico , Doenças da Aorta/terapia