Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
1.
Int J Clin Pract ; 75(3): e13820, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33164319

RESUMO

OBJECTIVE: The MINERVA trial showed that in pacemaker patients with atrial fibrillation (AF) history, DDDRP pacing combining three algorithms - (a) atrial antitachycardia pacing with Reactive ATP enabled, (b) atrial preventive pacing and (c) managed ventricular pacing (MVP)-may effectively delay progression to persistent/permanent AF compared with standard DDDR pacing. We performed a comparative non-randomised evaluation to evaluate if Reactive ATP can be the main driver of persistent/permanent AF reduction independently on preventive pacing. METHODS: Thirty-one centres included consecutive dual-chamber pacemaker patients with AF history. Reactive ATP was programmed in all patients while preventive atrial pacing was not enabled. These patients were compared with the three groups of MINERVA randomised trial (Control DDDR, MVP, and DDDRP). The main endpoint was the incidence of AF longer than 7 consecutive days. RESULTS: A total of 146 patients (73 years old, 54% male) were included and followed for a median observation period of 31 months. The 2-year incidence of AF > 7 days was 12% in the Reactive ATP group, very similar to that found in the DDDRP arm of the MINERVA trial (13.8%, P = .732) and significantly lower than AF incidence found in the MINERVA Control DDDR arm (25.8%, P = .012) and in the MINERVA MVP arm (25.9%, P = .025). CONCLUSIONS: In a real-world population of dual-chamber pacemaker patients with AF history, the use of Reactive ATP is associated with a low incidence of persistent AF, highlighting that the positive results of the MINERVA trial were related to the effectiveness of Reactive ATP rather than to preventive pacing.


Assuntos
Fibrilação Atrial , Marca-Passo Artificial , Idoso , Fibrilação Atrial/prevenção & controle , Estimulação Cardíaca Artificial , Feminino , Átrios do Coração , Humanos , Incidência , Masculino , Resultado do Tratamento
2.
Europace ; 19(9): 1418-1426, 2017 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-28525585

RESUMO

The difference between men and women is clear even just by looking at an electrocardiogram: females present higher resting heart rate, a shorter QRS complex length and greater corrected QT interval. The development of these differences from pubertal age onward suggests that sexual hormones play a key role, although their effect is far from being completely understood. Different incidences between sexes have been reported for many arrhythmias, both ventricular and supraventricular, and also for sudden cardiac death. Moreover, arrhythmias are an important issue during pregnancy, both for diagnosis and treatment. Interestingly, cardiovascular structural and electrophysiological remodelling promoted by exercise training enhances this 'gender effect'. Despite all these relevant issues, we lack gender specific recommendations in the current guidelines for electrical therapies for heart rhythm disorders and heart failure. Even more, we continue to see that fewer women are included in clinical trials and are less referred than men for these treatments.


Assuntos
Arritmias Cardíacas/terapia , Acessibilidade aos Serviços de Saúde , Disparidades nos Níveis de Saúde , Disparidades em Assistência à Saúde , Sistema de Condução Cardíaco/fisiopatologia , Potenciais de Ação , Animais , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/epidemiologia , Arritmias Cardíacas/fisiopatologia , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Feminino , Frequência Cardíaca , Humanos , Masculino , Gravidez , Fatores Sexuais , Resultado do Tratamento
3.
Europace ; 19(2): 282-288, 2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28175255

RESUMO

Aims: Several pacing modalities across multiple manufacturers have been introduced to minimize unnecessary right ventricular pacing. We conducted a meta-analysis to assess whether ventricular pacing reduction modalities (VPRM) influence hard clinical outcomes in comparison to standard dual-chamber pacing (DDD). Methods and Results: An electronic search was performed using Cochrane Central Register, PubMed, Embase, and Scopus. Only randomized controlled trials (RCT) were included in this analysis. Outcomes of interest included: frequency of ventricular pacing (VP), incident persistent/permanent atrial fibrillation (PerAF), all-cause hospitalization and all-cause mortality. Odds ratios (OR) were reported for dichotomous variables. Seven RCTs involving 4119 adult patients were identified. Ventricular pacing reduction modalities were employed in 2069 patients: (MVP, Medtronic Inc.) in 1423 and (SafeR, Sorin CRM, Clamart) in 646 patients. Baseline demographics and clinical characteristics were similar between VPRM and DDD groups. The mean follow-up period was 2.5 ± 0.9 years. Ventricular pacing reduction modalities showed uniform reduction in VP in comparison to DDD groups among all individual studies. The incidence of PerAF was similar between both groups {8 vs. 10%, OR 0.84 [95% confidence interval (CI) 0.57; 1.24], P = 0.38}. Ventricular pacing reduction modalities showed no significant differences in comparison to DDD for all-cause hospitalization or all-cause mortality [9 vs. 11%, OR 0.82 (95% CI 0.65; 1.03), P= 0.09; 6 vs. 6%, OR 0.97 (95% CI 0.74; 1.28), P = 0.84, respectively]. Conclusion: Novel VPRM measures effectively reduce VP in comparison to standard DDD. When actively programmed, VPRM did not improve clinical outcomes and were not superior to standard DDD programming in reducing incidence of PerAF, all-cause hospitalization, or all-cause mortality.


Assuntos
Fibrilação Atrial/epidemiologia , Estimulação Cardíaca Artificial/métodos , Hospitalização/estatística & dados numéricos , Mortalidade , Função Ventricular Esquerda , Função Ventricular Direita , Idoso , Causas de Morte , Feminino , Átrios do Coração , Humanos , Incidência , Masculino , Razão de Chances , Procedimentos Desnecessários
4.
Europace ; 19(12): 1911-1921, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-28520959

RESUMO

Use of cardiac implantable devices and catheter ablation is steadily increasing in Western countries following the positive results of clinical trials. Despite the advances in scientific knowledge, tools development, and techniques improvement we still have some grey area in the field of electrical therapies for the heart. In particular, several reports highlighted differences both in medical behaviour and procedural outcomes between female and male candidates. Women are referred later for catheter ablation of supraventricular arrhythmias, especially atrial fibrillation, leading to suboptimal results. On the opposite females present greater response to cardiac resynchronization, while the benefit of implantable defibrillator in primary prevention seems to be less pronounced. Differences on aetiology, clinical profile, and development of myocardial scarring are the more plausible causes. This review will discuss all these aspects together with gender-related differences in terms of acute/late complications. We will also provide useful hints on plausible mechanisms and practical procedural aspects.


Assuntos
Arritmias Cardíacas/terapia , Ablação por Cateter , Cardioversão Elétrica , Disparidades em Assistência à Saúde , Avaliação de Processos em Cuidados de Saúde , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Terapia de Ressincronização Cardíaca/efeitos adversos , Terapia de Ressincronização Cardíaca/mortalidade , Dispositivos de Terapia de Ressincronização Cardíaca , Ablação por Cateter/efeitos adversos , Ablação por Cateter/mortalidade , Congressos como Assunto , Desfibriladores Implantáveis , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/mortalidade , Feminino , Disparidades nos Níveis de Saúde , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Fatores Sexuais , Resultado do Tratamento
5.
J Cardiovasc Electrophysiol ; 25(5): 500-506, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24494797

RESUMO

INTRODUCTION: The left ventricular (LV) pacing site and the magnitude of the electrical delay within the LV, as expressed by prolonged QRS duration, are major determinants of cardiac resynchronization therapy (CRT) efficacy. We investigated the incremental value of positioning the LV lead in areas of late activation in order to enhance the response to CRT in patients with different degrees of QRS complex lengthening. METHODS AND RESULTS: This analysis was performed on 301 heart failure patients who received a CRT defibrillator. On implantation, the right ventricular (RV)-to-LV interval was measured as the delay between local activations recorded through the RV and LV leads in the final position. After 1 year, 171 (57%) patients displayed reverse LV remodeling, as measured by a ≥15% reduction in the LV end-systolic volume. Both the RV-to-LV interval and its percentage value corrected for the QRS duration were significantly associated with a positive response to CRT. An RV-to-LV interval >80 milliseconds and an RV-to-LV interval/QRS >58% yielded the best prediction of reverse remodeling. Although the response to CRT decreased with shorter QRS duration in the overall population, patients with an RV-to-LV interval >80 milliseconds showed a response rate >65% in all QRS subgroups. CONCLUSION: A longer RV-to-LV interval is associated with reverse LV remodeling after CRT. On implantation attempts could be made to maximize it when selecting the LV lead position, especially in patients with shorter QRS duration, and thus less likely to respond positively to CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Sistema de Condução Cardíaco/fisiopatologia , Insuficiência Cardíaca/terapia , Ventrículos do Coração/fisiopatologia , Função Ventricular Esquerda , Função Ventricular Direita , Potenciais de Ação , Idoso , Eletrocardiografia , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo , Resultado do Tratamento , Remodelação Ventricular
6.
BMC Cardiovasc Disord ; 12: 72, 2012 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-22966862

RESUMO

BACKGROUND: A multicenter European Registry, SEARCH-MI, was instituted in the year 2002 in order to assess patients' outcomes and ICD interventions in patients with a previous MI and depressed LV function, treated with an ICD according to MADIT II results. In this analysis, we evaluate the influence of the time elapsed between last myocardial infarction (MI) and prophylactic cardioverter defibrillator (ICD) implant on device activations. METHODS: 643 patients with left ventricular dysfunction (mean LVEF 26 ± 5%) and NYHA class I-III were prospectively followed for 1.8 ± 1.2 years in a multicenter registry. The population was divided into 3 groups according to the time between last MI and ICD implant: [1] from 40 days to less than 1.5 years; [2] from 1.5 to less than 7 years and [3] at least 7 years. RESULTS: The cumulative incidence of ventricular tachyarrhymias and appropriate device therapy (ATP or shock) were higher in patients implanted longer time from last MI (Gray's Test p=0.002 and p=0.013 respectively). No significant differences were seen in all cause mortality (Gray's Test p=0.618) or sudden cardiac death across the MI stratification groups (Gray's Test p=0.663). CONCLUSIONS: Patients implanted with an ICD longer after the MI have a higher chance of presenting ventricular tachyarrhythmias and appropriate ICD therapy, while no differences were seen in overall mortality. These observations may be important for improving patient targeting in sudden death prevention.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Infarto do Miocárdio/complicações , Prevenção Primária/instrumentação , Disfunção Ventricular Esquerda/terapia , Idoso , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Distribuição de Qui-Quadrado , Morte Súbita Cardíaca/etiologia , Cardioversão Elétrica/efeitos adversos , Cardioversão Elétrica/mortalidade , Desenho de Equipamento , Europa (Continente) , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/mortalidade , Prevenção Primária/métodos , Modelos de Riscos Proporcionais , Sistema de Registros , Medição de Risco , Fatores de Risco , Volume Sistólico , Fatores de Tempo , Resultado do Tratamento , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/etiologia , Disfunção Ventricular Esquerda/mortalidade , Disfunção Ventricular Esquerda/fisiopatologia , Função Ventricular Esquerda
7.
Pacing Clin Electrophysiol ; 35(2): 146-54, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22132940

RESUMO

BACKGROUND: We assessed the influence of clinically significant mitral regurgitation (MR) on clinical-echocardiographic response and outcome in heart failure (HF) patients treated with a biventricular defibrillator (cardiac resynchronization therapy defibrillator [CRT-D]). METHODS AND RESULTS: A total of 659 HF patients underwent successful implantation of CRT-D and were enrolled in a multicenter prospective registry (median follow-up of 15 months). Following baseline echocardiographic evaluation, patients were stratified into two groups according to the severity of MR: 232 patients with more than mild MR (Group MR+: grade 2, 3, and 4 MR) versus 427 patients with mild (grade 1) or no functional MR (Group MR-). On 6- and 12-month echocardiographic evaluation, MR was seen to have improved in the vast majority of MR+ patients, while it remained unchanged in most MR- patients. On 12-month follow-up evaluation, a comparable response to CRT was observed in the two groups, in terms of the extent of left ventricular reverse remodeling and combined clinical and echocardiographic response. During long-term follow-up, event-free survival did not differ between MR+ and MR- patients, even when subpopulations of patients with ischemic heart disease and with dilated cardiomyopathy were analyzed separately. On multivariate analysis, the only independent predictor of death from any cause was the lack of ß-blocker use. CONCLUSIONS: This observational analysis supports the use of CRT-D in HF patients with clinically significant MR; MR had no major influence on patient outcome.


Assuntos
Terapia de Ressincronização Cardíaca/mortalidade , Insuficiência Cardíaca/mortalidade , Insuficiência Cardíaca/prevenção & controle , Insuficiência da Valva Mitral/mortalidade , Insuficiência da Valva Mitral/prevenção & controle , Sistema de Registros , Idoso , Comorbidade , Feminino , Humanos , Itália/epidemiologia , Masculino , Prevalência , Medição de Risco/métodos , Fatores de Risco , Análise de Sobrevida , Taxa de Sobrevida , Resultado do Tratamento
8.
Eur Heart J ; 32(19): 2420-9, 2011 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-21606084

RESUMO

AIMS: On the basis of the current knowledge, cardiac resynchronization therapy (CRT) cannot be recommended as a first-line treatment for patients with severely symptomatic permanent atrial fibrillation undergoing atrioventricular (AV) junction ablation. We examined whether CRT was superior to conventional right ventricular (RV) pacing in reducing heart failure (HF) events. METHODS AND RESULTS: In this prospective, multi-centre study, we randomly assigned 186 patients, in whom AV junction ablation and CRT device implantation had been successfully performed, to receive optimized echo-guided CRT (97 patients) or RV apical pacing (89 patients). The data were analysed according to the intention-to-treat principle. During a median follow-up of 20 months (interquartile range 11-24), the primary composite endpoint of death from HF, hospitalization due to HF, or worsening HF occurred in 11 (11%) patients in the CRT group and 23 (26%) patients in the RV group [CRT vs. RV group: sub-hazard ratio (SHR) 0.37 ( 95% CI 0.18-0.73), P = 0.005]. In the CRT group, compared with the RV group, fewer patients had worsening HF [SHR 0.27 (95% CI 0.12-0.58), P = 0.001] and hospitalizations for HF [SHR 0.20 (95% CI 0.06-0.72), P = 0.013]. Total mortality was similar in both groups [hazard ratio (HR) 1.57 (95% CI 0.58-4.27), P = 0.372]. The beneficial effects of CRT were consistent in patients who had ejection fraction ≤35%, New York Heart Association Class ≥III and QRS width ≥120 and in those who did not. At multi-variable Cox regression, only CRT mode remained an independent predictor of absence of clinical failure during the follow-up [HR = 0.23 (95% CI 0.08-0.66), P = 0.007]. CONCLUSIONS: In patients undergoing 'Ablate and Pace' therapy for severely symptomatic permanent atrial fibrillation, CRT is superior to RV apical pacing in reducing the clinical manifestations of HF. (ClinicalTrials.gov number: NCT00111527).


Assuntos
Fibrilação Atrial/terapia , Terapia de Ressincronização Cardíaca/métodos , Ablação por Cateter/métodos , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/fisiopatologia , Dispositivos de Terapia de Ressincronização Cardíaca , Terapia Combinada , Ecocardiografia , Feminino , Humanos , Masculino , Estudos Prospectivos , Fatores de Risco , Volume Sistólico , Resultado do Tratamento
9.
Adv Ther ; 38(6): 2891-2907, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-34019247

RESUMO

Vitamin K antagonists have been used for many years as the treatment of choice for long-term oral anticoagulation in patients with non-valvular atrial fibrillation. Unfortunately, the use of those drugs in the real-world setting, particularly among elderly patients, is suboptimal because of their limitations in management. Therefore, many patients were not adequately anticoagulated. Direct oral anticoagulants have been demonstrated to overcome almost all the limitations derived from the use of vitamin K antagonists. Direct oral anticoagulants are at least as effective as vitamin K antagonists in preventing thromboembolic events in patients with non-valvular atrial fibrillation and safer in reducing the risk of intracranial haemorrhage and all-cause mortality. However, as a result of the strict inclusion and exclusion criteria applied to patients, data coming from randomized controlled trials might not apply to the general population. Furthermore, elderly patients were scarcely represented in randomized controlled trials with direct oral anticoagulants. Therefore in elderly patients with non-valvular atrial fibrillation, unmet clinical needs still exist. This review article highlights some of them and provides potential answers based on the results coming from randomized clinical trials, real-world data, and the authors' clinical experience.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Administração Oral , Idoso , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Fibrilação Atrial/tratamento farmacológico , Humanos , Ensaios Clínicos Controlados Aleatórios como Assunto , Acidente Vascular Cerebral/tratamento farmacológico , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
10.
Eur Heart J ; 30(18): 2275-83, 2009 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-19515689

RESUMO

AIMS: To analyse the effectiveness of cardiac resynchronization therapy (CRT) in patients with valvular heart disease (a subset not specifically investigated in randomized controlled trials) in comparison with ischaemic heart disease or dilated cardiomyopathy patients. METHODS AND RESULTS: Patients enrolled in a national registry were evaluated during a median follow-up of 16 months after CRT implant. Patients with valvular heart disease treated with CRT (n = 108) in comparison with ischaemic heart disease (n = 737) and dilated cardiomyopathy (n = 635) patients presented: (i) a higher prevalence of chronic atrial fibrillation, with atrioventricular node ablation performed in around half of the cases; (ii) a similar clinical and echocardiographic profile at baseline; (iii) a similar improvement of LVEF and a similar reduction in ventricular volumes at 6-12 months; (iv) a favourable clinical response at 12 months with an improvement of the clinical composite score similar to that occurring in patients with dilated cardiomyopathy and more pronounced than that observed in patients with ischaemic heart disease; (v) a long-term outcome, in term of freedom from death or heart transplantation, similar to patients affected by ischaemic heart disease and basically more severe than that of patients affected by dilated cardiomyopathy. CONCLUSION: In 'real world' clinical practice, CRT appears to be effective also in patients with valvular heart disease. However, in this group of patients the outcome after CRT does not precisely overlap any of the two other groups of patients, for which much more data are currently available.


Assuntos
Estimulação Cardíaca Artificial , Cardiomiopatia Dilatada/terapia , Insuficiência Cardíaca/terapia , Doenças das Valvas Cardíacas/complicações , Isquemia Miocárdica/terapia , Idoso , Fibrilação Atrial/etiologia , Fibrilação Atrial/cirurgia , Desfibriladores Implantáveis , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Sistema de Registros , Resultado do Tratamento , Remodelação Ventricular
11.
Europace ; 11(4): 476-82, 2009 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-19136492

RESUMO

AIMS: To evaluate clinical and arrhythmic outcomes in post-infarction cardiomyopathy patients implanted with a defibrillator (ICD) for primary prevention of sudden death. METHODS AND RESULTS: The SEARCH-MI registry is a European multi-centre, prospective, observational study enrolling patients after myocardial infarction, chronic left ventricular dysfunction and an ICD implanted for primary prevention of sudden death. Data on 556 patients with at least one recorded follow-up are presented. Survey to Evaluate Arrhythmia Rate in High-risk MI (SEARCH-MI) patients were sicker than those enrolled in MADIT-II with higher New York Heart Association class and left bundle branch block. Total mortality was 10.4%. Close to one-third (30%) of patients experienced episodes of sustained ventricular arrhythmia. One-quarter (23%) received at least one appropriate therapy and 10% inappropriate therapy. Gender (25% males vs. 5% females, P = 0.0009) and history of non-sustained ventricular tachycardia (24% with vs. 18% without P = 0.037) were predictive of appropriate ventricular therapy. CONCLUSION: SEARCH-MI represents the current clinical management of post-MI patients with left ventricular dysfunction indicated to defibrillator implant for primary prevention. European routine clinical practice was influenced by landmark trials and guidelines which impacted on the implantation of cardiac resynchronization therapy in over 25% of such patients. Non-sustained ventricular tachycardia identifies subjects with a higher incidence of appropriate ICD therapy.


Assuntos
Arritmias Cardíacas/terapia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Infarto do Miocárdio/complicações , Avaliação de Resultados em Cuidados de Saúde , Sistema de Registros , Idoso , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/fisiopatologia , Morte Súbita Cardíaca/etiologia , Europa (Continente) , Feminino , Fidelidade a Diretrizes , Inquéritos Epidemiológicos , Humanos , Incidência , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/complicações , Disfunção Ventricular Esquerda/fisiopatologia
12.
Europace ; 11(8): 1097-107, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19525498

RESUMO

Patients with an implantable cardioverter defibrillator (ICD) have an ongoing risk of sudden incapacitation that might cause harm to others while driving a car. Driving restrictions vary across different countries in Europe. The most recent recommendations for driving of ICD patients in Europe were published in 1997 and focused mainly on patients implanted for secondary prevention. In recent years there has been a vast increase in the number of patients with an ICD and in the percentage of patients implanted for primary prevention. The EHRA task force on ICD and driving was formed to reassess the risk of driving for ICD patients based on the literature available. The recommendations are summarized in the following table and are further explained in the document. [table: see text] Driving restrictions are perceived as difficult for patients and their families, and have an immediate consequence for their lifestyle. To increase the adherence to the driving restrictions, adequate discharge of education and follow-up of patients and family are pivotal. The task force members hope this document may serve as an instrument for European and national regulatory authorities to formulate uniform driving regulations.


Assuntos
Acidentes de Trânsito/prevenção & controle , Condução de Veículo/normas , Desfibriladores Implantáveis , Avaliação da Deficiência , Licenciamento/normas , Guias de Prática Clínica como Assunto , Prevenção de Acidentes , Europa (Continente) , Medição de Risco/normas
13.
Am Heart J ; 156(2): 373.e1-8, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18657671

RESUMO

BACKGROUND: Atrial tachyarrhythmias (ATAs) are mainly treated by pharmacologic therapy for rate control or rhythm control. The aim of our study was to compare sotalol (S) versus beta-blocking agents (BB) in terms of prevention of ATA, cardioversions (CVs), and cardiovascular hospitalizations (H) in patients paced for bradycardia-tachycardia form of sinus node disease (BT-SND). METHODS: One hundred thirty-five patients (67 males, aged 73 +/- 7 years) were enrolled in a prospective, parallel, randomized, single-blind, multicenter study. All patients received a dual chamber rate adaptive pacemaker; after 1 month, 66 patients were randomly assigned to BB (62 +/- 26 and 104 +/- 47 mg/d for atenolol and metoprolol, respectively) and 69 patients to S (167 +/- 66 mg/d). RESULTS: After an observation period of 12 months, the percentage of patients free from ATA recurrences was 29% in both BB and S group. Cardioversion and H were significantly (P < .01) fewer in the 12 months after implantation than in the 12 months before both in patients treated with S (CV 69.4% vs 22.2%, H 91.7% vs 33.3%) and in patients treated with BB (CV 58.5% vs 17.1%, H 82.9% vs 26.8%). Kaplan-Meier survival analysis showed a nonsignificant trend toward a lower incidence of the composite end point (CV + H) among BB patients. CONCLUSIONS: In the complex context of "hybrid therapy" in patients with BT-SND implanted with a modern dual chamber rate adaptive pacemaker device delivering atrial antitachycardia pacing, no differences were found between the use of beta-blocker and the use of S, at the relatively low dose achieved after clinical titration, in terms of prevention of cardiovascular H or need for atrial CV.


Assuntos
Antagonistas Adrenérgicos beta/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Marca-Passo Artificial , Sotalol/uso terapêutico , Antagonistas Adrenérgicos beta/efeitos adversos , Idoso , Bradicardia/complicações , Bradicardia/terapia , Estimulação Cardíaca Artificial , Feminino , Humanos , Masculino , Estudos Prospectivos , Método Simples-Cego , Sotalol/efeitos adversos , Taquicardia/complicações , Taquicardia/terapia
14.
Europace ; 10(3): 321-6, 2008 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-18308753

RESUMO

AIMS: Several clinical studies have shown that, in patients with intact atrioventricular (AV) conduction, unnecessary chronic right ventricular (RV) pacing can be detrimental. The managed ventricular pacing (MVP) algorithm is designed to give preference to spontaneous AV conduction, thus minimizing RV pacing. The clinical outcomes of MVP are being studied in several ongoing trials in patients undergoing a first device implantation, but it is unknown to what extent MVP is beneficial in patients with a history of ventricular pacing. The purpose of the Prefer for Elective Replacement MVP (PreFER MVP) study is to assess the superiority of the MVP algorithm to conventional pacemaker and implantable cardioverter-defibrillator programming in terms of freedom from hospitalization for cardiovascular causes in a population of patients exposed to long periods of ventricular pacing. METHODS AND RESULTS: PreFER MVP is a prospective, 1:1 parallel, randomized (MVP ON/MVP OFF), single-blinded multi-centre trial. The study population consists of patients with more than 40% ventricular pacing documented with their previous device. Approximately, 600 patients will be randomized and followed for at least 24 months. The primary endpoint comprises cardiovascular hospitalization. CONCLUSION: The PreFER MVP trial is the first large prospective randomized clinical trial evaluating the effect of MVP in patients with a history of RV pacing.


Assuntos
Algoritmos , Estimulação Cardíaca Artificial/métodos , Doenças Cardiovasculares/terapia , Desfibriladores Implantáveis , Ventrículos do Coração/fisiopatologia , Marca-Passo Artificial , Austrália , Canadá , Doenças Cardiovasculares/fisiopatologia , Europa (Continente) , Seguimentos , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Oriente Médio , Estudos Prospectivos , Método Simples-Cego
15.
J Cardiovasc Med (Hagerstown) ; 19(4): 161-169, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29470250

RESUMO

: Modern pacemakers have an increasing number of programable parameters and specific algorithms designed to optimize pacing therapy in relation to the individual characteristics of patients. When choosing the most appropriate pacemaker type and programing, the following variables must be taken into account: the type of bradyarrhythmia at the time of pacemaker implantation; the cardiac chamber requiring pacing, and the percentage of pacing actually needed to correct the rhythm disorder; the possible association of multiple rhythm disturbances and conduction diseases; the evolution of conduction disorders during follow-up. The goals of device programing are to preserve or restore the heart rate response to metabolic and hemodynamic demands; to maintain physiological conduction; to maximize device longevity; to detect, prevent, and treat atrial arrhythmia. In patients with sinus node disease, the optimal pacing mode is DDDR. Based on all the available evidence, in this setting, we consider appropriate the activation of the following algorithms: rate responsive function in patients with chronotropic incompetence; algorithms to maximize intrinsic atrioventricular conduction in the absence of atrioventricular blocks; mode-switch algorithms; algorithms for autoadaptive management of the atrial pacing output; algorithms for the prevention and treatment of atrial tachyarrhythmias in the subgroup of patients with atrial tachyarrhythmias/atrial fibrillation. The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features.


Assuntos
Bradicardia/terapia , Estimulação Cardíaca Artificial/normas , Marca-Passo Artificial/classificação , Síndrome do Nó Sinusal/complicações , Algoritmos , Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/terapia , Consenso , Hemodinâmica , Humanos , Itália , Sociedades Médicas , Taquicardia/prevenção & controle , Taquicardia/terapia
16.
J Cardiovasc Med (Hagerstown) ; 19(4): 170-180, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29470251

RESUMO

: The purpose of this two-part consensus document is to provide specific suggestions (based on an extensive literature review) on appropriate pacemaker setting in relation to patients' clinical features. In part 2, criteria for pacemaker choice and programming in atrioventricular blocks and neurally mediate syncope are proposed. The atrioventricular blocks can be paroxysmal or persistent, isolated or associated with sinus node disease. Neurally mediated syncope can be related to carotid sinus syndrome or cardioinhibitory vasovagal syncope. In sinus rhythm, with persistent atrioventricular block, we considered appropriate the activation of mode-switch algorithms, and algorithms for auto-adaptive management of the ventricular pacing output. If the atrioventricular block is paroxysmal, in addition to algorithms mentioned above, algorithms to maximize intrinsic atrioventricular conduction should be activated. When sinus node disease is associated with atrioventricular block, the activation of rate-responsive function in patients with chronotropic incompetence is appropriate. In permanent atrial fibrillation with atrioventricular block, algorithms for auto-adaptive management of the ventricular pacing output should be activated. If the atrioventricular block is persistent, the activation of rate-responsive function is appropriate. In carotid sinus syndrome, adequate rate hysteresis should be programmed. In vasovagal syncope, specialized sensing and pacing algorithms designed for reflex syncope prevention should be activated.


Assuntos
Bloqueio Atrioventricular/complicações , Bradicardia/terapia , Estimulação Cardíaca Artificial/normas , Marca-Passo Artificial/classificação , Síncope Vasovagal/complicações , Algoritmos , Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/terapia , Consenso , Hemodinâmica , Humanos , Itália , Síndrome do Nó Sinusal/complicações , Sociedades Médicas
17.
J Am Coll Cardiol ; 71(23): 2603-2611, 2018 06 12.
Artigo em Inglês | MEDLINE | ID: mdl-29880119

RESUMO

BACKGROUND: Long-term continuous monitoring detects short-lasting, subclinical atrial fibrillation (SCAF) in approximately one-third of older individuals with cardiovascular conditions. The relationship between SCAF, its progression, and the development of heart failure (HF) is unclear. OBJECTIVES: This study examined the relationship between progression from shorter to longer SCAF episodes and HF hospitalization. METHODS: Subjects in ASSERT (Asymptomatic Atrial Fibrillation and Stroke Evaluation in Pacemaker Patients and the Atrial Fibrillation Reduction Atrial Pacing Trial) were ≥65 years old, had history of hypertension, no prior clinical AF, and an implanted pacemaker or defibrillator. We examined patients whose longest SCAF episode during the first year after enrollment was >6 min but ≤24 h (n = 415). Using time-dependent Cox models, we evaluated the relationship between subsequent development of SCAF >24 h or clinical AF and HF hospitalization. RESULTS: Over a mean follow-up of 2 years, 65 patients (15.7%) progressed to having SCAF episodes >24 h or clinical AF (incidence 8.8% per year). Older age, greater body mass index, and longer SCAF duration within the first year were independent predictors of SCAF progression. The rate of HF hospitalization among patients with SCAF progression was 8.9% per year compared with 2.5% per year for those without progression. After multivariable adjustment, SCAF progression was independently associated with HF hospitalization (hazard ratio [HR]: 4.58; 95% confidence interval [CI]: 1.64 to 12.80; p = 0.004). Similar results were observed when we excluded patients with prior history of HF (HR: 7.06; 95% CI: 1.82 to 27.30; p = 0.005) or when SCAF progression was defined as development of SCAF >24 h alone (HR: 3.68; 95% CI: 1.27 to 10.70; p = 0.016). CONCLUSIONS: In patients with a pacemaker or defibrillator, SCAF progression was strongly associated with HF hospitalization.


Assuntos
Fibrilação Atrial/epidemiologia , Fibrilação Atrial/fisiopatologia , Progressão da Doença , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/fisiopatologia , Marca-Passo Artificial/tendências , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/diagnóstico , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Humanos , Masculino , Marca-Passo Artificial/efeitos adversos , Fatores de Risco
18.
Am Heart J ; 154(1): 193-200, 2007 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-17584576

RESUMO

BACKGROUND: In sinus node disease (SND) atrial tachyarrhythmias (ATs) may frequently occur, after implant of a pacemaker for bradycardia, and are to be managed by rate or rhythm control. METHODS: We evaluated ventricular heart rate (HR) during AT, AT-related symptoms and hospitalizations in 333 patients who received DDDRP pacemakers for SND. RESULTS: In days with 24 hours of AT, mean daily HR during AT was > 80, 90, 100, 110, and 120 beats per minute (bpm) in 191 (57%), 114 (34%), 55 (16%), 23 (7%), and 11 (3%) patients, respectively. The proportion of patients with a mean daily HR > 80 bpm during AT despite the use of rate control agents was 28% among patients treated with calcium-channel blockers, 43% with digoxin, 49% with a combination of agents, 54% with amiodarone, 64% with sotalol, and 69% with beta blockers. Patients with HR > 100 bpm experienced a higher prevalence of both AT-related hospitalizations and cardiovascular hospitalizations than those with HR < or = 100 bpm (36% vs 21%, P = .013; 42% vs 28%, P = .003) and a significantly higher number of AT-related symptoms (1.8 +/- 0.9 vs 1.4 +/- 1.0, P = .008). CONCLUSIONS: Limited attention has been dedicated to rate control in patients with pacemaker. This is the first study to evaluate the prevalence and implications of inappropriate rate control in patients with pacemaker. We found that in a substantial proportion of patients with SND who have recurrent ATs despite pacing, mean daily HR during AT is high and that these patients present increased hospitalizations and more symptoms, thus suggesting the need to improve rate control.


Assuntos
Estimulação Cardíaca Artificial , Frequência Cardíaca , Marca-Passo Artificial , Síndrome do Nó Sinusal/fisiopatologia , Síndrome do Nó Sinusal/terapia , Antagonistas Adrenérgicos beta/uso terapêutico , Idoso , Antiarrítmicos/uso terapêutico , Desfibriladores Implantáveis , Eletrocardiografia Ambulatorial , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Síndrome do Nó Sinusal/mortalidade , Taxa de Sobrevida
19.
Circulation ; 105(23): 2741-5, 2002 Jun 11.
Artigo em Inglês | MEDLINE | ID: mdl-12057988

RESUMO

BACKGROUND: In patients with syncope and structural heart disease, syncope is suspected to be attributable to a primary cardiac arrhythmia, but little is known of its mechanism when electrophysiologic study is unremarkable. METHODS AND RESULTS: We applied an implantable loop recorder in 35 patients with overt heart disease at risk of ventricular arrhythmia, because these were patients with previous myocardial infarction or cardiomyopathy with depressed ejection fraction or nonsustained ventricular tachycardia in whom an electrophysiologic study was unremarkable. During a follow-up of 3 to 15 months, syncope recurred in 6 patients (17%) after a mean of 6+/-5 months; in 3 patients, the mechanism of syncope was bradycardia with long pauses (sudden-onset AV block in 2 cases and sinus arrest in 1 case); in 1 patient, there was stable sinus tachycardia; and in 2 patients, who had chronic atrial fibrillation, there was an increase in ventricular rate. A total of 23 episodes of presyncope were documented in 8 patients (23%): no rhythm variation or mild tachycardia in 12 cases, paroxysmal atrial fibrillation or atrial tachycardia in 10 cases, and sustained ventricular tachycardia in 1 case. No patient died during the study period nor suffered from injury attributable to syncopal relapse. CONCLUSIONS: The patients with unexplained syncope, structural heart disease, and negative electrophysiologic study had a favorable medium-term outcome with no case of death and a low recurrence rate of syncope without related injury. The mechanism of syncope was heterogeneous, and ventricular tachyarrhythmia was unlikely.


Assuntos
Arritmias Cardíacas/complicações , Cardiomiopatias/complicações , Síncope/etiologia , Idoso , Arritmias Cardíacas/diagnóstico , Cardiomiopatias/diagnóstico , Intervalo Livre de Doença , Eletrocardiografia , Técnicas Eletrofisiológicas Cardíacas , Determinação de Ponto Final , Feminino , Seguimentos , Humanos , Masculino , Próteses e Implantes
20.
Heart Rhythm ; 2(10): 1047-57, 2005 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-16188580

RESUMO

BACKGROUND: Atrial tachyarrhythmias (AT) are considered progressive diseases. Several rhythm control therapies for treatment of AT have been proposed. OBJECTIVES: The Italian AT500 Registry was designed to prospectively study long-term AT evolution in patients paced for the brady-tachy form of sinus node disease (BT-SND). METHODS: Three hundred forty-six BT-SND patients received an antitachycardia dual-chamber pacemaker and were followed-up for a minimum of 12 months (median 19 months). Prevention and antitachycardia pacing (ATP) features were enabled in all patients. RESULTS: During the observation period, 224 (65%) patients were treated by antiarrhythmic drugs and 45 (13%) patients were cardioverted. Five patients suffered a stroke, 4 transient ischemic attack, 22 permanent AT, and 98 AT recurrences longer than 7 days. AT mean cycle length changed from 246 to 270 ms, and the percentage of patients with AT-related hospitalizations significantly decreased with an annual 28% relative reduction. AT burden and the percentage of patients with AT recurrences longer than 2 days remained constant with time in the overall population but decreased significantly in the subgroup of patients who did not develop permanent AT. High ATP efficacy was associated with an increasingly higher prevention of AT recurrences longer than 2 days. CONCLUSION: In a long-term observation of BT-SND patients, AT-related hospitalizations decreased significantly and mean AT cycle length increased significantly. The data suggest that rhythm control therapies induce inversion of AT progression.


Assuntos
Bradicardia/terapia , Estimulação Cardíaca Artificial , Taquicardia Atrial Ectópica/terapia , Idoso , Antiarrítmicos/uso terapêutico , Bradicardia/fisiopatologia , Cardioversão Elétrica , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Sistema de Condução Cardíaco/efeitos dos fármacos , Sistema de Condução Cardíaco/fisiopatologia , Sistema de Condução Cardíaco/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Admissão do Paciente , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Prospectivos , Recidiva , Síndrome do Nó Sinusal/fisiopatologia , Síndrome do Nó Sinusal/terapia , Síndrome , Taquicardia/fisiopatologia , Taquicardia/terapia , Taquicardia Atrial Ectópica/fisiopatologia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA