Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Radiol ; 20(3): 674-82, 2010 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19760240

RESUMO

OBJECTIVE: To assess the relationship between MRI-derived changes in whole-brain and ventricular volume with change in cognitive scores in Alzheimer's disease (AD), mild cognitive impairment (MCI) and control subjects. MATERIAL AND METHODS: In total 131 control, 231 MCI and 99 AD subjects from the Alzheimer's Disease Neuroimaging Initiative (ADNI) cohort with T1-weighted volumetric MRIs from baseline and 12-month follow-up were used to derive volume changes. Mini mental state examination (MMSE), Alzheimer's disease assessment scale (ADAS)-cog and trails test changes were calculated over the same period. RESULTS: Brain atrophy rates and ventricular enlargement differed between subject groups (p < 0.0005) and in MCI and AD were associated with MMSE changes. Both measures were additionally associated with ADAS-cog and trails-B in MCI patients, and ventricular expansion was associated with ADAS-cog in AD patients. Brain atrophy (p < 0.0005) and ventricular expansion rates (p = 0.001) were higher in MCI subjects who progressed to AD within 12 months of follow-up compared with MCI subjects who remained stable. MCI subjects who progressed to AD within 12 months had similar atrophy rates to AD subjects. CONCLUSION: Whole-brain atrophy rates and ventricular enlargement differed between patient groups and healthy controls, and tracked disease progression and psychological decline, demonstrating their relevance as biomarkers.


Assuntos
Doença de Alzheimer/complicações , Doença de Alzheimer/patologia , Encéfalo/patologia , Transtornos Cognitivos/diagnóstico , Transtornos Cognitivos/etiologia , Imageamento Tridimensional/métodos , Imageamento por Ressonância Magnética/métodos , Idoso , Feminino , Humanos , Masculino , Tamanho do Órgão , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Eur Radiol ; 19(12): 2826-33, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19618189

RESUMO

We investigated progression of atrophy in vivo, in Alzheimer's disease (AD), and mild cognitive impairment (MCI). We included 64 patients with AD, 44 with MCI and 34 controls with serial MRI examinations (interval 1.8 ± 0.7 years). A nonlinear registration algorithm (fluid) was used to calculate atrophy rates in six regions: frontal, medial temporal, temporal (extramedial), parietal, occipital lobes and insular cortex. In MCI, the highest atrophy rate was observed in the medial temporal lobe, comparable with AD. AD patients showed even higher atrophy rates in the extramedial temporal lobe. Additionally, atrophy rates in frontal, parietal and occipital lobes were increased. Cox proportional hazard models showed that all regional atrophy rates predicted conversion to AD. Hazard ratios varied between 2.6 (95% confidence interval (CI) = 1.1-6.2) for occipital atrophy and 15.8 (95% CI = 3.5-71.8) for medial temporal lobe atrophy. In conclusion, atrophy spreads through the brain with development of AD. MCI is marked by temporal lobe atrophy. In AD, atrophy rate in the extramedial temporal lobe was even higher. Moreover, atrophy rates also accelerated in parietal, frontal, insular and occipital lobes. Finally, in nondemented elderly, medial temporal lobe atrophy was most predictive of progression to AD, demonstrating the involvement of this region in the development of AD.


Assuntos
Envelhecimento/patologia , Doença de Alzheimer/patologia , Encéfalo/patologia , Transtornos Cognitivos/patologia , Imageamento por Ressonância Magnética/métodos , Idoso , Doença de Alzheimer/complicações , Atrofia/patologia , Transtornos Cognitivos/etiologia , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
3.
Neuroimage ; 41(1): 19-34, 2008 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-18378167

RESUMO

Tensor-based morphometry (TBM) creates three-dimensional maps of disease-related differences in brain structure, based on nonlinearly registering brain MRI scans to a common image template. Using two different TBM designs (averaging individual differences versus aligning group average templates), we compared the anatomical distribution of brain atrophy in 40 patients with Alzheimer's disease (AD), 40 healthy elderly controls, and 40 individuals with amnestic mild cognitive impairment (aMCI), a condition conferring increased risk for AD. We created an unbiased geometrical average image template for each of the three groups, which were matched for sex and age (mean age: 76.1 years+/-7.7 SD). We warped each individual brain image (N=120) to the control group average template to create Jacobian maps, which show the local expansion or compression factor at each point in the image, reflecting individual volumetric differences. Statistical maps of group differences revealed widespread medial temporal and limbic atrophy in AD, with a lesser, more restricted distribution in MCI. Atrophy and CSF space expansion both correlated strongly with Mini-Mental State Exam (MMSE) scores and Clinical Dementia Rating (CDR). Using cumulative p-value plots, we investigated how detection sensitivity was influenced by the sample size, the choice of search region (whole brain, temporal lobe, hippocampus), the initial linear registration method (9- versus 12-parameter), and the type of TBM design. In the future, TBM may help to (1) identify factors that resist or accelerate the disease process, and (2) measure disease burden in treatment trials.


Assuntos
Doença de Alzheimer/patologia , Encéfalo/patologia , Transtornos Cognitivos/patologia , Idoso , Idoso de 80 Anos ou mais , Algoritmos , Doença de Alzheimer/psicologia , Atrofia , Mapeamento Encefálico , Transtornos Cognitivos/psicologia , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Escalas de Graduação Psiquiátrica
4.
J Neurol ; 255(4): 567-74, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18274807

RESUMO

BACKGROUND: Both cognitive tests and MRI-based measures have been suggested as outcomes in trials assessing disease-modifying therapies in Alzheimer's disease (AD). OBJECTIVE: To compare changes in longitudinal MRI measures with changes in performance on cognitive tests routinely used in AD clinical trials. METHOD: Fifty-two subjects from the placebo-arm of a clinical trial in mild-to-moderate AD had volumetric T(1)-weighted scans and cognitive tests including the Mini-Mental State Examination (MMSE), AD Assessment Scale-Cognitive Subscale, Disability Assessment for Dementia, AD Cooperative Study-Clinical Global Impression of Change and Clinical Dementia Rating at baseline and one-year later. Rates of brain atrophy and ventricular enlargement were measured using the boundary shift integral. Hippocampal (Hc) atrophy was calculated from manual volume measurements. The relationships between MRI and cognitive measures were investigated. RESULTS: Rates of brain atrophy and/or ventricular enlargement were correlated with declining performance on cognitive scales. The strongest association was between brain atrophy rate and MMSE decline (r = 0.59, p < 0.0001). Hc atrophy rate was not significantly correlated with any of the cognitive scales. CONCLUSION: The lack of correlation between Hc atrophy and cognitive scales may reflect a combination of: the extensive functional damage to the Hc by the time AD is clinically established, the greater influence of ongoing cortical degeneration, and errors in Hc outlining. The strong correlations between brain atrophy and ventricular enlargement, and cognitive scales probably reflect the correspondence between these measures of overall cerebral loss and global cognitive measures in the moderate stages of AD.


Assuntos
Doença de Alzheimer/diagnóstico , Doença de Alzheimer/psicologia , Atrofia/patologia , Encéfalo/patologia , Transtornos Cognitivos/diagnóstico , Idoso , Idoso de 80 Anos ou mais , Doença de Alzheimer/fisiopatologia , Atrofia/etiologia , Atrofia/fisiopatologia , Biomarcadores/análise , Encéfalo/fisiopatologia , Mapeamento Encefálico , Transtornos Cognitivos/etiologia , Transtornos Cognitivos/fisiopatologia , Progressão da Doença , Método Duplo-Cego , Feminino , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Testes Neuropsicológicos , Placebos , Valor Preditivo dos Testes , Prognóstico
5.
Arch Neurol ; 64(6): 849-54, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17562933

RESUMO

OBJECTIVE: To compare an automated intensity-based measure of medial temporal atrophy in Alzheimer disease (AD) with existing volumetric and visually based methods. DESIGN: Longitudinal study comparing a medial temporal atrophy measure with 2 criterion standards: (1) total hippocampal (HC) volume adjusted for total intracranial volume and (2) standard visual rating scale of medial temporal atrophy. SETTING: Cognitive disorders specialist clinic. PARTICIPANTS: Forty-seven patients with AD and 26 age- and sex-matched controls. INTERVENTION: Subjects were scanned using volumetric T1-weighted magnetic resonance imaging at baseline and 1 year later. MAIN OUTCOME MEASURE: Automated Medial Temporal Lobe Atrophy Scale (ATLAS) score, derived from dividing mean intensity of a standardized perihippocampal volume by that of a standardized pontine volume. RESULTS: Patients with AD had significantly reduced ATLAS scores and HC volumes and increased visual rating scores at baseline and repeat scanning. Rates of HC atrophy and decline in the ATLAS score were significantly higher in patients with AD compared with controls. The ATLAS scores were significantly correlated with HC volumes and visual rating scores. With specificity set at 85%, the sensitivities of HC volume and visual rating scale score were similar (84% and 86%, respectively), whereas ATLAS score had a lower sensitivity (73%). At repeat scanning, all 3 measures had similar sensitivities (86%-87%). Rate of decline in the ATLAS score required a similar sample size to HC atrophy rate to provide statistical power to clinical trials, but being automated, it is less labor intensive. CONCLUSIONS: Like the visual rating scale, ATLAS is a simple medial temporal atrophy measure, which has the additional advantage of being able to track AD progression on serial imaging.


Assuntos
Doença de Alzheimer/diagnóstico , Atrofia/diagnóstico , Imageamento por Ressonância Magnética/métodos , Lobo Temporal , Idoso , Automação , Encéfalo/patologia , Feminino , Hipocampo/patologia , Humanos , Estudos Longitudinais , Imageamento por Ressonância Magnética/normas , Masculino , Tamanho da Amostra , Sensibilidade e Especificidade , Método Simples-Cego
6.
Neuroimage ; 39(4): 1752-62, 2008 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-18063391

RESUMO

Measures of structural brain change based on longitudinal MR imaging are increasingly important but can be degraded by intensity non-uniformity. This non-uniformity can be more pronounced at higher field strengths, or when using multichannel receiver coils. We assessed the ability of the non-parametric non-uniform intensity normalization (N3) technique to correct non-uniformity in 72 volumetric brain MR scans from the preparatory phase of the Alzheimer's Disease Neuroimaging Initiative (ADNI). Normal elderly subjects (n=18) were scanned on different 3-T scanners with a multichannel phased array receiver coil at baseline, using magnetization prepared rapid gradient echo (MP-RAGE) and spoiled gradient echo (SPGR) pulse sequences, and again 2 weeks later. When applying N3, we used five brain masks of varying accuracy and four spline smoothing distances (d=50, 100, 150 and 200 mm) to ascertain which combination of parameters optimally reduces the non-uniformity. We used the normalized white matter intensity variance (standard deviation/mean) to ascertain quantitatively the correction for a single scan; we used the variance of the normalized difference image to assess quantitatively the consistency of the correction over time from registered scan pairs. Our results showed statistically significant (p<0.01) improvement in uniformity for individual scans and reduction in the normalized difference image variance when using masks that identified distinct brain tissue classes, and when using smaller spline smoothing distances (e.g., 50-100 mm) for both MP-RAGE and SPGR pulse sequences. These optimized settings may assist future large-scale studies where 3-T scanners and phased array receiver coils are used, such as ADNI, so that intensity non-uniformity does not influence the power of MR imaging to detect disease progression and the factors that influence it.


Assuntos
Doença de Alzheimer/patologia , Imageamento por Ressonância Magnética/instrumentação , Idoso , Algoritmos , Encéfalo/patologia , Calibragem , Transtornos Cognitivos/patologia , Interpretação Estatística de Dados , Humanos , Processamento de Imagem Assistida por Computador , Reprodutibilidade dos Testes
7.
Neurobiol Aging ; 28(1): 20-8, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16406154

RESUMO

This study explores the diagnostic utility of atrophy rates of the cingulate gyrus, its subdivisions and the hippocampus in Alzheimer's disease (AD) and frontotemporal lobar degeneration (FTLD). Regions were manually outlined on MR images of a group of pathologically or genetically confirmed patients with AD (n=19), FTLD (n=8) and age-matched controls (n=11). Mean (S.D.) atrophy rates (%year(-1)) in the cingulate in controls, AD and FTLD were -0.3 (1.2), 5.9 (3.5), and 8.6 (4.1), respectively. Hippocampal atrophy rates in controls, AD and FTLD were -0.1 (0.8), 3.4 (2.2), and 5.2 (5.4), respectively. Atrophy rates were significantly higher in the cingulate and hippocampi in AD and FTLD compared with controls (p<0.01). There was evidence of a difference in trends of atrophy in the cingulate (more anterior in FTLD and more posterior in AD) between the disease groups (p=0.03). Cingulate atrophy rates discriminated perfectly between FTLD and controls. Significantly better discrimination between AD and controls was obtained by hippocampal rather than cingulate rates. In conclusion, cingulate atrophy is as significant a feature of AD and FTLD as hippocampal atrophy.


Assuntos
Doença de Alzheimer/diagnóstico , Demência/diagnóstico , Giro do Cíngulo/patologia , Hipocampo/patologia , Imageamento por Ressonância Magnética/métodos , Medição de Risco/métodos , Atrofia/diagnóstico , Diagnóstico Diferencial , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade
8.
Neuroimage ; 32(1): 159-69, 2006 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-16675272

RESUMO

We compared two methods of measuring cerebral atrophy in a cohort of 38 clinically probable Alzheimer's disease (AD) subjects and 22 age-matched normal controls, using metrics of zero atrophy, consistency, scaled atrophy and AD/control group separation. The two methods compared were the boundary shift integral (BSI) and a technique based on the integration of Jacobian determinants from non-rigid registration. For each subject, we used two volumetric magnetic resonance (MR) scans at baseline and a third obtained 1 year later. The case of zero atrophy was established by registering the same-day baseline scan pair, which should approximate zero change. Consistency was established by registering the 1-year follow-up scan to each of the baseline scans, giving two measurements of atrophy that should be very similar, while scaled atrophy was established by reducing one of the same-day scans by a fixed amount, and rigidly registering this to the other same-day scan. Group separation was ascertained by calculating atrophy rates over the two 1-year measures for the control and AD subjects. The results showed the Jacobian integration technique was significantly more accurate in calculating scaled atrophy (P < 0.001) and was able to distinguish between control and AD subjects more clearly (P < 0.01).


Assuntos
Doença de Alzheimer/patologia , Encéfalo/anatomia & histologia , Encéfalo/patologia , Imageamento por Ressonância Magnética , Idoso , Artefatos , Atrofia/patologia , Humanos , Modelos Neurológicos , Movimento , Valores de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
9.
Neuroimage ; 23(2): 574-81, 2004 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-15488407

RESUMO

Manual segmentation of the hippocampus is the gold standard in volumetric hippocampal magnetic resonance imaging (MRI) analysis; however, this is difficult to achieve reproducibly. This study explores whether application of local registration and calculation of the hippocampal boundary shift integral (HBSI) can reduce random variation compared with manual measures. Hippocampi were outlined on the baseline and registered-repeat MRIs of 32 clinically diagnosed Alzheimer's disease (AD) patients and 47 matched controls (37-86 years) with a wide range of scanning intervals (175-1173 days). The scans were globally registered using 9 degrees of freedom and subsequently locally registered using 6 degrees of freedom and HBSI was then calculated automatically. HBSI significantly reduced the mean rate (P < 0.01) and variation in controls (P < 0.001) and increased group separation between AD cases and controls. When comparing HBSI atrophy rates with manually derived atrophy rates at 90% sensitivity, specificities were 98% and 81%, respectively. From logistic regression models, a 1% increase in HBSI atrophy rates was associated with an 11-fold (CI 3, 36) increase in the odds of a diagnosis of AD. For manually derived atrophy rates, the equivalent odds ratio was 3 (CI 2,4). We conclude that HBSI-derived atrophy rates reduce operator time and error, and are at least as effective as the manual equivalent as a diagnostic marker and are a potential marker of progression in longitudinal studies and trials.


Assuntos
Envelhecimento/patologia , Doença de Alzheimer/diagnóstico , Doença de Alzheimer/patologia , Hipocampo/patologia , Idoso , Algoritmos , Atrofia , Diagnóstico Diferencial , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA