Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Biomol NMR ; 62(4): 453-71, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25801209

RESUMO

The automated assignment of NOESY cross peaks has become a fundamental technique for NMR protein structure analysis. A widely used algorithm for this purpose is implemented in the program CYANA. It has been used for a large number of structure determinations of proteins in solution but was so far not described in full detail. In this paper we present a complete description of the CYANA implementation of automated NOESY assignment, which differs extensively from its predecessor CANDID by the use of a consistent probabilistic treatment, and we discuss its performance in the second round of the critical assessment of structure determination by NMR.


Assuntos
Modelos Moleculares , Ressonância Magnética Nuclear Biomolecular/métodos , Conformação Proteica , Proteínas/química , Algoritmos , Software
2.
J Biomol NMR ; 62(1): 81-95, 2015 May.
Artigo em Inglês | MEDLINE | ID: mdl-25796507

RESUMO

The automated assignment of NOESY cross peaks has become a fundamental technique for NMR protein structure analysis. A widely used algorithm for this purpose is implemented in the program CYANA. It has been used for a large number of structure determinations of proteins in solution but a systematic evaluation of its performance has not yet been reported. In this paper we systematically analyze the reliability of combined automated NOESY assignment and structure calculation with CYANA under a variety of conditions on the basis of the experimental NMR data sets of ten proteins. To evaluate the robustness of the algorithm, the original high-quality experimental data sets were modified in different ways to simulate the effect of data imperfections, i.e. incomplete or erroneous chemical shift assignments, missing NOESY cross peaks, inaccurate peak positions, inaccurate peak intensities, lower dimensionality NOESY spectra, and higher tolerances for the matching of chemical shifts and peak positions. The results show that the algorithm is remarkably robust with regard to imperfections of the NOESY peak lists and the chemical shift tolerances but susceptible to lacking or erroneous resonance assignments, in particular for nuclei that are involved in many NOESY cross peaks.


Assuntos
Ressonância Magnética Nuclear Biomolecular/métodos , Proteínas/química , Algoritmos , Animais , Proteínas de Bactérias/química , Humanos , Proteínas de Plantas/química , Conformação Proteica , Reprodutibilidade dos Testes
3.
J Biomol NMR ; 55(3): 267-77, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23329391

RESUMO

Peak lists are commonly used in NMR as input data for various software tools such as automatic assignment and structure calculation programs. Inconsistencies of chemical shift referencing among different peak lists or between peak and chemical shift lists can cause severe problems during peak assignment. Here we present a simple and robust tool to achieve self-consistency of the chemical shift referencing among a set of peak lists. The Peakmatch algorithm matches a set of peak lists to a specified reference peak list, neither of which have to be assigned. The chemical shift referencing offset between two peak lists is determined by optimizing an assignment-free match score function using either a complete grid search or downhill simplex optimization. It is shown that peak lists from many different types of spectra can be matched reliably as long as they contain at least two corresponding dimensions. Using a simulated peak list, the Peakmatch algorithm can also be used to obtain the optimal agreement between a chemical shift list and experimental peak lists. Combining these features makes Peakmatch a useful tool that can be applied routinely before automatic assignment or structure calculation in order to obtain an optimized input data set.


Assuntos
Algoritmos , Ressonância Magnética Nuclear Biomolecular/métodos , Modelos Moleculares , Conformação Proteica , Proteínas/química
4.
J Biomol NMR ; 56(3): 243-54, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23689812

RESUMO

Solid-state NMR is an emerging structure determination technique for crystalline and non-crystalline protein assemblies, e.g., amyloids. Resonance assignment constitutes the first and often very time-consuming step to a structure. We present ssFLYA, a generally applicable algorithm for automatic assignment of protein solid-state NMR spectra. Application to microcrystals of ubiquitin and the Ure2 prion C-terminal domain, as well as amyloids of HET-s(218-289) and α-synuclein yielded 88-97 % correctness for the backbone and side-chain assignments that are classified as self-consistent by the algorithm, and 77-90 % correctness if also assignments classified as tentative by the algorithm are included.


Assuntos
Amiloide/química , Ressonância Magnética Nuclear Biomolecular , Proteínas/química , Algoritmos , Sequência de Aminoácidos , Dados de Sequência Molecular , Ubiquitina/química , alfa-Sinucleína/química
5.
Nat Commun ; 8(1): 2101, 2017 12 13.
Artigo em Inglês | MEDLINE | ID: mdl-29235475

RESUMO

The two isoforms of the Bcr-Abl tyrosine kinase, p210 and p190, are associated with different leukemias and have a dramatically different signaling network, despite similar kinase activity. To provide a molecular rationale for these observations, we study the Dbl-homology (DH) and Pleckstrin-homology (PH) domains of Bcr-Abl p210, which constitute the only structural differences to p190. Here we report high-resolution structures of the DH and PH domains and characterize conformations of the DH-PH unit in solution. Our structural and functional analyses show no evidence that the DH domain acts as a guanine nucleotide exchange factor, whereas the PH domain binds to various phosphatidylinositol-phosphates. PH-domain mutants alter subcellular localization and result in decreased interactions with p210-selective interaction partners. Hence, the PH domain, but not the DH domain, plays an important role in the formation of the differential p210 and p190 Bcr-Abl signaling networks.


Assuntos
Proteínas de Fusão bcr-abl/química , Modelos Moleculares , Domínios de Homologia à Plecstrina , Domínios Proteicos , Carcinogênese , Cristalografia por Raios X , Proteínas de Fusão bcr-abl/genética , Proteínas de Fusão bcr-abl/metabolismo , Humanos , Leucemia/genética , Leucemia/metabolismo , Espectroscopia de Ressonância Magnética , Espalhamento a Baixo Ângulo , Transdução de Sinais , Difração de Raios X
6.
Cell Death Differ ; 23(12): 1930-1940, 2016 12.
Artigo em Inglês | MEDLINE | ID: mdl-27716744

RESUMO

Members of the p53 tumor-suppressor family are expressed as multiple isoforms. Isoforms with an N-terminal transactivation domain are transcriptionally active, while those ones lacking this domain often inhibit the transcriptional activity of other family members. In squamous cell carcinomas, the high expression level of ΔNp63α inhibits the tumor-suppressor function of TAp73ß. This can in principle be due to blocking of the promoter or by direct interaction between both proteins. p63 and p73 can hetero-oligomerize through their tetramerization domains and a hetero-tetramer consisting of two p63 and two p73 molecules is thermodynamically more stable than both homo-tetramers. Here we show that cells expressing both p63 and p73 exist in mouse epidermis and hair follicle and that hetero-tetramer complexes can be detected by immunoprecipitation in differentiating keratinocytes. Through structure determination of the hetero-tetramer, we reveal why this hetero-tetramer is the thermodynamically preferred species. We have created mutants that exclusively form either hetero-tetramers or homo-tetramers, allowing to investigate the function of these p63/p73 hetero-tetramers. Using these tools, we show that inhibition of TAp73ß in squamous cell carcinomas is due to promoter squelching and not direct interaction.


Assuntos
Fosfoproteínas/química , Fosfoproteínas/metabolismo , Multimerização Proteica , Transativadores/química , Transativadores/metabolismo , Proteína Tumoral p73/química , Proteína Tumoral p73/metabolismo , Sequência de Aminoácidos , Animais , Humanos , Camundongos , Mutação/genética , Regiões Promotoras Genéticas/genética , Ligação Proteica , Sais/química , Transcrição Gênica
7.
Structure ; 23(2): 425-34, 2015 Feb 03.
Artigo em Inglês | MEDLINE | ID: mdl-25579816

RESUMO

Nuclear magnetic resonance (NMR) structures are represented by bundles of conformers calculated from different randomized initial structures using identical experimental input data. The spread among these conformers indicates the precision of the atomic coordinates. However, there is as yet no reliable measure of structural accuracy, i.e., how close NMR conformers are to the "true" structure. Instead, the precision of structure bundles is widely (mis)interpreted as a measure of structural quality. Attempts to increase precision often overestimate accuracy by tight bundles of high precision but much lower accuracy. To overcome this problem, we introduce a protocol for NMR structure determination with the software package CYANA, which produces, like the traditional method, bundles of conformers in agreement with a common set of conformational restraints but with a realistic precision that is, throughout a variety of proteins and NMR data sets, a much better estimate of structural accuracy than the precision of conventional structure bundles.


Assuntos
Algoritmos , Modelos Moleculares , Ressonância Magnética Nuclear Biomolecular/métodos , Proteínas/química , Software , Conformação Proteica , Reprodutibilidade dos Testes
8.
J Magn Reson ; 249: 88-93, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25462951

RESUMO

The automated chemical shift assignment algorithm FLYA has been extended for use with stereo-array isotope labeled (SAIL) proteins to determine the sequence-specific resonance assignments of large proteins. Here we present the assignment of the backbone and sidechain chemical shifts of the 21kDa thioldisulfide oxidoreductase DsbA from Escherichia coli that were determined with the SAIL-FLYA algorithm in conjunction with automated peak picking. No manual corrections of peak lists or assignments were applied. The assignments agreed with manually determined reference assignments in 95.4% of the cases if 16 input spectra were used, 94.1% if only 3D 13C/15N-resolved NOESY, CBCA(CO)NH, and 2D [13C/15N,1H]-HSQC were used, and 86.8% if exclusively 3D 13C/15N-resolved NOESY spectra were used. Considering only the assignments that are classified as reliable by the SAIL-FLYA algorithm, the degrees of agreement increased to 97.5%, 96.5%, and 94.2%, respectively. With our approach it is thus possible to automatically obtain almost complete and correct assignments of proteins larger than 20kDa.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA