Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Catheter Cardiovasc Interv ; 94(3): 334-341, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30597737

RESUMO

BACKGROUND: The ION Study assessed clinical outcomes for the thin-strut, ION™ (TAXUS Element) Paclitaxel-Eluting Platinum Chromium Coronary Stent System (Boston Scientific, Marlborough, MA) in unselected patients. METHODS: This prospective, open-label registry enrolled the first 1,120 consenting patients treated with the ION stent without clinical or angiographic inclusion criteria at 40 clinical sites. Follow-up was at discharge, 30 days, 180 days, 1 and 2 years. The primary endpoint, the 1-year rate of cardiac death or MI (CD/MI) in PERSEUS-like patients (i.e., patients similar to those enrolled in PERSEUS, the pivotal approval trial), was tested in patients pooled from the ION study (N = 316), the European TAXUS Element post-approval registry (TE-PROVE; N = 306 PERSEUS-like patients), and the PERSEUS WH/SV populations (N = 1,166); and then compared with a prespecified performance goal. Additional outcomes were examined in the overall ION patient population. RESULTS: A total of 1,111 (out of 1,120) enrolled patients received a study stent. Most patients were male (70%) and mean age was 64 years. At 1 year, the primary endpoint of CD/MI occurred in 2.1% (6/292) of PERSEUS-like patients in ION, and 2.3% (40/1,729) of patients in the combined analysis. The upper one-sided 95% confidence interval for the combined analysis was 2.9%, which was significantly less than the performance goal of 7.6% (P < 0.001). Within patients enrolled in the ION study (N = 1,111), the rate of CD/MI was 4.5% at 1 year and 7.5% at 2 years. Definite/probable stent thrombosis occurred in 2.1% of patients at 1 year and 2.5% at 2 years. CONCLUSIONS: The results of the ION Study confirm the mid-term safety and effectiveness of the ION stent for the treatment of coronary artery disease in everyday clinical practice.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Platina , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Paclitaxel/efeitos adversos , Vigilância de Produtos Comercializados , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
2.
Catheter Cardiovasc Interv ; 93(2): 222-230, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30144337

RESUMO

BACKGROUND: The risk of contrast-induced acute kidney injury (CI-AKI) increases in a nonlinear fashion with increasing volume of contrast media. Prior studies recommend limiting contrast volume to less than three times the estimated creatinine clearance (CC). Recently, a number of operators have reported successful percutaneous coronary intervention (PCI) using even lower volumes of contrast. OBJECTIVES: To evaluate the prevalence and outcomes associated with ultra-low contrast volume among patients undergoing PCI. METHODS: We assessed the prevalence and outcomes associated with use of ultra-low contrast volume among 75 393 patients undergoing PCI in Michigan between July 2014 and June 2017 in the BMC2 (Blue Cross Blue Shield of Michigan Cardiovascular Consortium) registry. Ultra-low contrast volume was defined as contrast volume less than or equal to the patient's estimated CC. Patients receiving dialysis at the time of the procedure were excluded. RESULTS: Ultra-low contrast volume was used in 13% of procedures with the majority of these patients being at low risk of renal complications. Compared with patients who received a contrast volume between one and three times the CC, use of ultra-low volume of contrast was associated with a significantly lower incidence of AKI (aOR 0.682, 95% CI 0.566-0.821, P < 0.001) and a lower incidence of need for dialysis (aOR = 0.341, 95% CI 0.165-0.704, P = 0.003). These benefits were most evident in the patients with a high baseline predicted risk of AKI. CONCLUSIONS: A small but clinically significant number of patients are treated with ultra-low contrast volume. Ultra-low contrast volume use is associated with a significant reduction in the incidence of AKI or need for dialysis. It may be prudent to consider this new threshold when performing PCI on patients who are at an increased risk of AKI.


Assuntos
Injúria Renal Aguda/induzido quimicamente , Meios de Contraste/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/epidemiologia , Injúria Renal Aguda/terapia , Idoso , Idoso de 80 Anos ou mais , Planos de Seguro Blue Cross Blue Shield , Meios de Contraste/administração & dosagem , Feminino , Humanos , Incidência , Masculino , Michigan/epidemiologia , Pessoa de Meia-Idade , Sistema de Registros , Diálise Renal , Fatores de Risco , Resultado do Tratamento
3.
Catheter Cardiovasc Interv ; 90(5): 724-732, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-28303632

RESUMO

BACKGROUND: Dialysis patients are at a higher risk of bleeding after percutaneous coronary intervention (PCI); however, due to their exclusion from randomized clinical trials, the optimal antithrombotic regimen for this population remains unknown. We sought to evaluate the comparative safety and effectiveness of bivalirudin monotherapy versus unfractionated heparin (UFH) monotherapy in dialysis patients undergoing PCI. METHODS: We included dialysis patients who underwent PCI in a multicenter registry between January 2010 and September 2015 at 47 Michigan hospitals. We compared in-hospital outcomes between bivalirudin versus UFH; excluding those treated with glycoprotein IIb/IIIa inhibitors. Optimal full matching was used to account for the nonrandom use of these drugs. RESULTS: Of 177,963 patients who underwent PCI, 4,303 (2.4%) were on dialysis. Among those, 1,257 (29.2%) received bivalirudin monotherapy and 2,112 (49.1%) received UFH monotherapy. Patients treated with bivalirudin had fewer comorbidities. After matching, there were no significant differences in outcomes between those who received bivalirudin versus UFH: bleeding (adjusted odds ratio: 0.67; 95% confidence interval: 0.41-1.07; P = 0.093); major bleeding (0.81; 0.19-3.50; P = 0.77); transfusion (1.01; 0.77-1.33; P = 0.96); repeat PCI (0.57; 0.14-2.24; P = 0.42); stent thrombosis (0.56; 0.05-5.83; P = 0.63); and death (0.84; 0.46-1.51; P = 0.55). CONCLUSIONS: We found no significant differences in in-hospital outcomes between bivalirudin and UFH monotherapy among dialysis patients undergoing PCI. Randomized clinical trials are needed to determine the optimal anticoagulant regimen for this population. © 2017 Wiley Periodicals, Inc.


Assuntos
Anticoagulantes/uso terapêutico , Antitrombinas/uso terapêutico , Planos de Seguro Blue Cross Blue Shield , Doença da Artéria Coronariana/terapia , Heparina/uso terapêutico , Fragmentos de Peptídeos/uso terapêutico , Intervenção Coronária Percutânea , Diálise Renal , Insuficiência Renal Crônica/terapia , Trombose/prevenção & controle , Idoso , Anticoagulantes/efeitos adversos , Antitrombinas/efeitos adversos , Pesquisa Comparativa da Efetividade , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Hemorragia/induzido quimicamente , Heparina/efeitos adversos , Hirudinas/efeitos adversos , Humanos , Modelos Logísticos , Masculino , Michigan , Pessoa de Meia-Idade , Razão de Chances , Fragmentos de Peptídeos/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Pontuação de Propensão , Proteínas Recombinantes/efeitos adversos , Proteínas Recombinantes/uso terapêutico , Sistema de Registros , Diálise Renal/efeitos adversos , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Stents , Trombose/diagnóstico , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
4.
J Interv Cardiol ; 30(4): 291-300, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28543770

RESUMO

OBJECTIVES: We sought to evaluate the patterns of use and outcomes associated with eptifibatide and abciximab administration among dialysis patients who underwent percutaneous coronary intervention (PCI). BACKGROUND: Contraindicated medications are frequently administered to dialysis patients undergoing PCI often resulting in adverse outcomes. Eptifibatide is a glycoprotein IIb/IIIa inhibitor that is often used during PCI and is contraindicated in dialysis. METHODS: We included dialysis patients who underwent PCI from January 2010 to September 2015 at 47 hospitals in Michigan. We compared outcomes between patients who received eptifibatide compared with abciximab. Both groups required concurrent treatment with unfractionated heparin only. In-hospital outcomes included repeat PCI, bleeding, major bleeding, need for transfusion, and death. Optimal full matching was used to adjust for non-random drug administration. RESULTS: Of 177 963 patients who underwent PCI, 4303 (2.4%) were on dialysis. Among those, 384 (8.9%) received eptifibatide and 100 (2.3%) received abciximab. Prior to matching, patients who received eptifibatide had higher pre-procedural hemoglobin levels (11.3 g/dL vs. 10.7 g/dL; P < 0.001) and less frequently had a history of myocardial infarction (36.5% vs. 52.0%; P = 0.005). After matching, there were no significant differences in in-hospital outcomes between eptifibatide and abciximab including transfusion (aOR: 1.15; 95%CI: 0.55-2.40; P = 0.70), bleeding (1.47; 0.64-3.40; P = 0.36), major bleeding (4.68; 0.42-52.3; P = 0.21), repeat PCI (0.38; 0.03-4.23; P = 0.43), and death (1.53; 0.2-9.05; P = 0.64). CONCLUSIONS: Despite being contraindicated in dialysis, eptifibatide was used approximately 3.5 times more frequently than abciximab among dialysis patients undergoing PCI but was associated with similar in-hospital outcomes.


Assuntos
Anticorpos Monoclonais/uso terapêutico , Fragmentos Fab das Imunoglobulinas/uso terapêutico , Peptídeos/uso terapêutico , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias/epidemiologia , Diálise Renal , Abciximab , Idoso , Planos de Seguro Blue Cross Blue Shield , Contraindicações de Medicamentos , Eptifibatida , Feminino , Heparina/uso terapêutico , Humanos , Masculino , Michigan , Pessoa de Meia-Idade , Infarto do Miocárdio/terapia , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Estudos Retrospectivos , Resultado do Tratamento
5.
Eur Heart J ; 37(24): 1902-9, 2016 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-26377400

RESUMO

AIM: The purpose of our study was to evaluate the relative impact of bivalirudin on bleeding outcomes associated with trans-radial interventions (TRI) in real world practice. METHODS AND RESULTS: Data for patients undergoing percutaneous coronary intervention (PCI) between January 2010 and March 2014 at the 47 hospitals participating in the Blue Cross Blue Shield of Michigan Cardiovascular Consortium (BMC2) were utilized. Propensity matching was used within cohorts defined by access site. The impact of bivalirudin use on in-hospital outcomes was evaluated with Fisher's exact tests. Among patients undergoing trans-femoral interventions (TFI), use of bivalirudin was associated with a reduction in bleeding compared with both glycoprotein IIb/IIIa inhibitors (GPI; 1.67 vs. 3.46%, absolute risk reduction (ARR) 1.79%, odds ratio, OR, 0.47, confidence interval, CI, 0.41-0.54, number needed to treat, NNT 56, P < 0.001) and heparin (1.26 vs. 1.76%, ARR 0.5%, OR 0.71, CI 0.61-0.82, NNT 197, P < 0.001). Among patients undergoing TRI, there was a more modest absolute reduction in bleeding with bivalirudin compared with GPI (0.79 vs. 1.41%, ARR 0.62%, OR 0.56, CI 0.34-0.90, NNT 161, P = 0.016) and no difference in bleeding compared with heparin (0.46 vs. 0.46%, OR 1, CI 0.54-1.84, P = 1). CONCLUSION: Bivalirudin is markedly efficacious in reducing bleeding in patients undergoing TFI. The reduction in bleeding associated with bivalirudin use is minimal to absent in patients undergoing TRI. Given its lower cost and comparable outcomes, heparin should be the preferred anticoagulation strategy in those undergoing radial PCI.


Assuntos
Fragmentos de Peptídeos/uso terapêutico , Anticoagulantes , Planos de Seguro Blue Cross Blue Shield , Heparina , Hirudinas , Humanos , Michigan , Intervenção Coronária Percutânea , Complexo Glicoproteico GPIIb-IIIa de Plaquetas , Proteínas Recombinantes/uso terapêutico , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 86(6): 994-1001, 2015 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-25678402

RESUMO

BACKGROUND: The TAXUS Element (ION) platinum chromium paclitaxel-eluting stent (PtCr-PES) incorporates a thin (81 µm) strut design with a similar polymer and drug dose density as prior PES. The pivotal PERSEUS trial program consisted of two studies: PERSEUS Workhorse (WH) and PERSEUS Small Vessel (SV). The PERSEUS WH trial demonstrated the PtCr-PES to be non-inferior to the predicate TAXUS Express PES (TE-PES) for target lesion failure (TLF) at 1 year and in-segment angiographic percent diameter stenosis at 9 months. The PERSEUS SV trial demonstrated the PtCr-PES to be superior to a historical bare metal stent (BMS) for angiographic late lumen loss at 9 months. Long-term (5-year) clinical outcomes following PtCr-PES have not been previously reported. METHODS: PERSEUS WH was a prospective, Bayesian, 3:1 randomized (PtCr-PES vs. TE-PES) trial in patients with lesion length ≤28 mm and vessel diameter ≥2.75 to ≤4.0 mm. PERSEUS SV was a prospective, single-arm trial in patients with lesion length ≤20 mm and vessel diameter ≥2.25 to <2.75 mm comparing PtCr-PES to a matched historical BMS control. RESULTS: Among randomized subjects in the PERSEUS WH study, clinical event rates at 5 years were similar between treatment groups, including TLF (12.9% TE-PES vs. 12.1% PtCr-PES; P = 0.66). In the PERSEUS SV study, 5-year rates of MACE, and TLF were significantly lower for PtCr-PES (vs. BMS) following adjustment for baseline characteristics and were primarily due to lower target lesion revascularization rates (27.2% BMS vs. 14.9% PtCr-PES; P = 0.049). CONCLUSIONS: At 5 years, the PtCr-PES provides efficacy and safety that is comparable to the TE-PES and superior efficacy with similar safety when compared with BMS in smaller caliber vessels. Cumulative stent thrombosis rates remained low and similar through 5 years for both DES platforms.


Assuntos
Angioplastia Coronária com Balão/métodos , Doença das Coronárias/terapia , Stents Farmacológicos , Paclitaxel/administração & dosagem , Desenho de Prótese/métodos , Adulto , Idoso , Angioplastia Coronária com Balão/mortalidade , Teorema de Bayes , Cromo/química , Angiografia Coronária/métodos , Doença das Coronárias/diagnóstico por imagem , Doença das Coronárias/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/mortalidade , Feminino , Seguimentos , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Platina/química , Estudos Prospectivos , Falha de Prótese , Medição de Risco , Índice de Gravidade de Doença , Método Simples-Cego , Estatísticas não Paramétricas , Taxa de Sobrevida , Taxus , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
Catheter Cardiovasc Interv ; 85(2): 207-15, 2015 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-24905795

RESUMO

OBJECTIVES: To report 1- and 2-year clinical outcomes of patients receiving platinum chromium everolimus-eluting stents (PtCr-EES) in the prospective, single-arm PLATINUM small vessel (SV) and long lesion (LL) studies. BACKGROUND: Small vessel diameter and long lesion length are independently associated with increased risk of adverse cardiac events after drug-eluting stent implantation. METHODS: The PLATINUM SV study enrolled 94 patients with coronary artery lesions in vessels ≥2.25 mm to <2.50 mm in diameter and ≤28 mm in length. The PLATINUM LL study enrolled 102 patients with lesions >24 to ≤34 mm long in vessels ≥2.50 to ≤4.25 mm in diameter. The primary endpoint for both studies was target lesion failure (TLF) at 1 year compared to a prespecified performance goal based on outcomes with the TAXUS Express paclitaxel-eluting stent in small vessels and long lesions. RESULTS: One-year TLF rates with the PtCr-EES were significantly (P < 0.001) lower than the predetermined performance goals: 2.4% versus 21.1% in the SV cohort and 3.2% versus 19.4% in the LL cohort. Cumulative rates of TLF to 2 years were 4.7% in the SV cohort and 8.8% in the LL cohort. No myocardial infarction or ARC definite/probable stent thromboses occurred in either cohort through 2-year follow-up. CONCLUSIONS: The clinical efficacy and safety outcomes observed in these small vessel and long lesion cohorts support the use of the PtCr-EES in the treatment of small diameter vessels and long lesions.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Cromo , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Platina , Sirolimo/análogos & derivados , Idoso , Doença da Artéria Coronariana/diagnóstico , Europa (Continente) , Everolimo , Feminino , Humanos , Japão , Masculino , Pessoa de Meia-Idade , Nova Zelândia , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
8.
Ren Fail ; 37(2): 187-91, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25519207

RESUMO

OBJECTIVE: Neutrophil gelatinase-associated lipocalin (NGAL) is produced in response to tubular injury. Contrast-induced acute kidney injury (CI-AKI) is associated with adverse outcomes in chronic kidney disease (CKD) patients. We sought to characterize blood NGAL level and the degree of kidney injury in CKD patients who underwent coronary angiography. METHODS: This study was a prospective, blinded assessment of blood samples obtained from patients with estimated glomerular filtration rates (eGFRs) between 15 and 90 mL/min/1.73 m2 undergoing elective coronary angiography with iodinated contrast. Blood NGAL and serum creatinine were measured at baseline, 1, 2, 4, 6, 12, 24 and 48 h after contrast administration. RESULTS: A total of 63 subjects with a mean eGFR of 48.17±16.45 mL/min/1.73 m2 were enrolled. There was a graded increase in baseline NGAL levels across worsening stages of CKD (p=0.0001). Post-procedure NGAL increased from baseline in each stage of CKD. Eight (12.7%) patients were diagnosed with CI-AKI by diagnostic criteria of 2012 KDIGO definition of CI-AKI, and seven (11.1%) patients developed subclinical CI-AKI defined by a twofold or greater rise in NGAL. There was no relationship between baseline eGFR and diabetes on the composite outcome of subclinical and clinical CI-AKI. CONCLUSIONS: Baseline and post-procedure NGAL are progressively elevated according to the baseline stage of CKD. Using a twofold rise in NGAL, 46.7% of composite CI-AKI is detected and complements the 53.3% of cases identified using KDIGO criteria. Traditional risk predictors were not independently associated with this composite outcome.


Assuntos
Injúria Renal Aguda , Proteínas de Fase Aguda , Meios de Contraste/efeitos adversos , Angiografia Coronária/efeitos adversos , Lipocalinas , Proteínas Proto-Oncogênicas , Insuficiência Renal Crônica , Injúria Renal Aguda/sangue , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/complicações , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/fisiopatologia , Proteínas de Fase Aguda/análise , Idoso , Doenças Assintomáticas , Biomarcadores/análise , Biomarcadores/sangue , Estudos de Coortes , Meios de Contraste/administração & dosagem , Angiografia Coronária/métodos , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular , Humanos , Lipocalina-2 , Lipocalinas/análise , Lipocalinas/sangue , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Prospectivos , Proteínas Proto-Oncogênicas/análise , Proteínas Proto-Oncogênicas/sangue , Insuficiência Renal Crônica/sangue , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/etiologia , Medição de Risco
9.
J Interv Cardiol ; 26(2): 131-6, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23369084

RESUMO

OBJECTIVE: To evaluate clinical and angiographic outcomes using a 1.20 mm diameter angioplasty catheter as part of a predilation strategy for coronary lesion treatment. BACKGROUND: Development of an angioplasty catheter with low crossing profile and small balloon diameter represents an opportunity to facilitate percutaneous revascularization of complex coronary disease. METHODS: Clinical and angiographic outcomes were evaluated following a predilation treatment strategy using a low profile, 1.20 mm angioplasty catheter. The primary end-point of procedural success was defined as successful device delivery, performance and lesion treatment without occurrence of perforation, flow-limiting dissection, reduction in baseline TIMI grade, or clinically significant arrhythmias, and with final achievement of TIMI 3 flow. In-hospital major adverse events were also determined. RESULTS: Among 71 patients (83 lesions), angiographic characteristics included: de novo lesion, 75.9%; saphenous vein graft 9.6%; lesion length (mean ± standard deviation), 12.27 ± 5.96 mm; reference vessel diameter, 2.61 ± 0.57 mm; lesion classification B2/C, 59.0%; baseline TIMI 0/1 flow, 4.8%. Procedural success was achieved for 98.5% (66/67) of patients. Catheter delivery to the target lesion was achieved in all patients, and the rate of device success with luminal improvement after predilation was 96.2% (75/78). No acute procedural complications were observed, and in-hospital target lesion failure occurred in 6 patients (8.5%) related to peri-procedural non-Q wave myocardial infarction. CONCLUSIONS: Coronary lesion predilation with a low profile, 1.20 mm angioplasty catheter is associated with favorable procedural safety and efficacy and may represent an effective treatment for complex coronary anatomy.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Cateterismo/instrumentação , Angiografia Coronária/métodos , Doença da Artéria Coronariana/terapia , Intervenção Coronária Percutânea/instrumentação , Complicações Pós-Operatórias/epidemiologia , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Cateterismo/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento
10.
Heart Surg Forum ; 16(2): E60-9, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23625478

RESUMO

OBJECTIVE: Oral P2Y12 platelet receptor inhibitors are a cornerstone of reducing complications in patients with acute coronary syndromes or coronary stents. Guidelines advocate discontinuing treatment with P2Y12 platelet receptor inhibitors before surgery. Cangrelor, a short-acting, reversible, intravenously administered P2Y12 platelet inhibitor is effective in achieving appropriate platelet inhibition in patients who are awaiting coronary artery bypass grafting (CABG) and require P2Y12 inhibition. The objective of this study was to assess the effects of preoperative cangrelor on the incidence of perioperative complications, which are currently unknown. METHODS: Patients (n = 210) requiring preoperative clinical administration of thienopyridine therapy were randomized in a multicenter, double-blinded study to receive cangrelor or placebo while awaiting CABG after discontinuation of the thienopyridine. Optimal platelet reactivity, which was defined as <240 P2Y12 platelet reaction units, was measured with serial point-of-care testing (VerifyNow). Pre- and postoperative outcomes, bleeding values, and transfusion rates were compared. To quantify potential risk factors for bleeding, we developed a multivariate logistic model. RESULTS: The differences between the groups in bleeding and perioperative transfusion rates were not significantly different. The rate of CABG-related bleeding was 11.8% (12/102) in cangrelor-treated patients and 10.4% (10/96) in the placebo group (P = .763). Transfusion rates for the groups were similar. Serious postoperative adverse events for the cangrelor and placebo groups were 7.8% (8/102) and 5.2% (5/96), respectively (P = .454). CONCLUSIONS: Compared with placebo, bridging patients with cangrelor prior to CABG effectively maintains platelet inhibition without increasing post-CABG complications, including bleeding and the need for transfusions. These data suggest cangrelor treatment is a potential strategy for bridging patients requiring P2Y12 receptor inhibition while they await surgery.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Transfusão de Sangue/estatística & dados numéricos , Ponte de Artéria Coronária/estatística & dados numéricos , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/prevenção & controle , Pré-Medicação/estatística & dados numéricos , Piridinas/administração & dosagem , Monofosfato de Adenosina/administração & dosagem , Administração Oral , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimioterapia Combinada/estatística & dados numéricos , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos/epidemiologia , Feminino , Humanos , Injeções Intravenosas , Masculino , Pessoa de Meia-Idade , Efeito Placebo , Inibidores da Agregação Plaquetária/administração & dosagem , Prevalência , Antagonistas do Receptor Purinérgico P2Y/administração & dosagem , Medição de Risco , Resultado do Tratamento , Estados Unidos/epidemiologia
11.
Am J Nephrol ; 35(6): 509-14, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22627273

RESUMO

BACKGROUND: Neutrophil gelatinase-associated lipocalin (NGAL, siderocalin) is a protein secreted by the kidney in the setting of acute kidney injury in an attempt to regulate and bind the release of catalytic iron from injured cells. We sought to evaluate the relationships between baseline NGAL, renal filtration function, and the degree of injury reflected by further increases in NGAL. METHODS: This study was a prospective, blinded assessment of blood samples taken from patients with estimated glomerular filtration rate (eGFR) <75 ml/min/1.73 m(2) undergoing non-urgent coronary angiography and intervention using iodinated contrast. Renal transplant recipients, dialysis patients, and administration of iodinated contrast in the prior 30 days were exclusion criteria. Plasma NGAL was measured using the Alere™ assay. Serum creatinine (Cr) was measured using calibrated methods at a core laboratory. Samples were obtained at baseline, 1, 2, 4, 6, 12, 24, and 48 h after contrast administration. RESULTS: A total of 63 subjects were enrolled with a mean age of 69.4 ± 9.1 years, 73% male, 35% with diabetes, and a mean eGFR of 47.82 ± 15.46 ml/min/1.73 m(2). The correlation between eGFR and NGAL was r = -0.61, 95% CI -0.74 to -0.44, p < 0.001. When stratified by baseline NGAL tertile, the peak NGAL observed for each group occurred at 29.0 ± 22.2 h and there was a twofold increase in the mean and peak change in NGAL across the tertiles. NGAL began to rise 6 h after contrast exposure and followed a similar course to serum Cr and at 48 h the overall mean NGAL was still rising. Only 2 patients sustained a rise in Cr of >25% or ≥0.5 mg/dl. Multivariate regression revealed that baseline NGAL (p < 0.001) and not eGFR (p = 0.95) was independently associated with the NGAL value at 48 h. CONCLUSIONS: Baseline NGAL is strongly correlated with eGFR in patients with reduced renal filtration function undergoing coronary angiography. The magnitude of rise in NGAL is positively associated with the baseline value and is analogous to the time course of Cr in blood after contrast exposure. NGAL and not eGFR is an independent predictor of changes in the post-procedure NGAL. A baseline NGAL level is necessary for the interpretation of NGAL levels in the evaluation of acute kidney injury.


Assuntos
Injúria Renal Aguda/sangue , Meios de Contraste/efeitos adversos , Lipocalinas/sangue , Proteínas Proto-Oncogênicas/sangue , Injúria Renal Aguda/induzido quimicamente , Injúria Renal Aguda/diagnóstico , Proteínas de Fase Aguda , Idoso , Idoso de 80 Anos ou mais , Biomarcadores/sangue , Angiografia Coronária/efeitos adversos , Creatinina/sangue , Feminino , Taxa de Filtração Glomerular , Humanos , Compostos de Iodo/efeitos adversos , Lipocalina-2 , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Análise de Regressão , Método Simples-Cego , Estatísticas não Paramétricas
12.
Catheter Cardiovasc Interv ; 80(4): 546-53, 2012 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-22121027

RESUMO

OBJECTIVES: The SPIRIT Small Vessel (SV) was designed to evaluate the safety and effectiveness of the 2.25-mm XIENCE V everolimus eluting coronary stent system (EECSS), known as the XIENCE nano EECSS, in subjects with SVs and ischemic heart disease. BACKGROUND: The core sizes of XIENCE V EECSS are associated with low rates of restenosis and thrombosis in the general population, but the XIENCE nano EECSS has not been tested in the United States. METHODS: This prospective, single-arm, open-label study was conducted at 33 centers and in 150 patients in the United States. The primary endpoint was the target lesion failure (TLF) rate at 1 year, required to meet the prespecified performance goal (PG) of 20.4%, derived from historical data. RESULTS: The mean patient age was 63 years, 38% were women, 39.2% were diabetic, 49.3% had multivessel disease, and the reference vessel diameter was 2.13 ± 0.23 mm. The 1-year TLF rate was 8.1% in with an upper limit of the one-sided 95% confidence interval of 13.0%, which met the PG of 20.4% (P < 0.0001). At 1 year, the rate of cardiac death was 1.5%, the target vessel myocardial infarction rate was 1.5%, and clinically indicated target lesion revascularization rate was 5.1%. The 8-month angiographic in-stent late loss was 0.2 ± 0.4 mm, respectively. The 1-year academic research consortium defined definite/probable stent thrombosis rate was 1.5%. CONCLUSIONS: Based on the 1-year clinical and 8-month angiographic SPIRIT SV data, the XIENCE nano EECSS is considered safe and effective in the treatment of SVs.


Assuntos
Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Nanomedicina , Sirolimo/análogos & derivados , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Trombose Coronária/diagnóstico por imagem , Trombose Coronária/etiologia , Everolimo , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/etiologia , Estudos Prospectivos , Desenho de Prótese , Sirolimo/administração & dosagem , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
13.
JAMA ; 307(3): 265-74, 2012 Jan 18.
Artigo em Inglês | MEDLINE | ID: mdl-22253393

RESUMO

CONTEXT: Thienopyridines are among the most widely prescribed medications, but their use can be complicated by the unanticipated need for surgery. Despite increased risk of thrombosis, guidelines recommend discontinuing thienopyridines 5 to 7 days prior to surgery to minimize bleeding. OBJECTIVE: To evaluate the use of cangrelor, an intravenous, reversible P2Y(12) platelet inhibitor for bridging thienopyridine-treated patients to coronary artery bypass grafting (CABG) surgery. DESIGN, SETTING, AND PATIENTS: Prospective, randomized, double-blind, placebo-controlled, multicenter trial, involving 210 patients with an acute coronary syndrome (ACS) or treated with a coronary stent and receiving a thienopyridine awaiting CABG surgery to receive either cangrelor or placebo after an initial open-label, dose-finding phase (n = 11) conducted between January 2009 and April 2011. Interventions Thienopyridines were stopped and patients were administered cangrelor or placebo for at least 48 hours, which was discontinued 1 to 6 hours before CABG surgery. MAIN OUTCOME MEASURES: The primary efficacy end point was platelet reactivity (measured in P2Y(12) reaction units [PRUs]), assessed daily. The main safety end point was excessive CABG surgery-related bleeding. RESULTS: The dose of cangrelor determined in 10 patients in the open-label stage was 0.75 µg/kg per minute. In the randomized phase, a greater proportion of patients treated with cangrelor had low levels of platelet reactivity throughout the entire treatment period compared with placebo (primary end point, PRU <240; 98.8% (83 of 84) vs 19.0% (16 of 84); relative risk [RR], 5.2 [95% CI, 3.3-8.1] P < .001). Excessive CABG surgery-related bleeding occurred in 11.8% (12 of 102) vs 10.4% (10 of 96) in the cangrelor and placebo groups, respectively (RR, 1.1 [95% CI, 0.5-2.5] P = .763). There were no significant differences in major bleeding prior to CABG surgery, although minor bleeding episodes were numerically higher with cangrelor. CONCLUSIONS: Among patients who discontinue thienopyridine therapy prior to cardiac surgery, the use of cangrelor compared with placebo resulted in a higher rate of maintenance of platelet inhibition. TRIAL REGISTRATION: clinicaltrials.gov Identifier: NCT00767507.


Assuntos
Monofosfato de Adenosina/análogos & derivados , Perda Sanguínea Cirúrgica , Ponte de Artéria Coronária , Inibidores da Agregação Plaquetária/uso terapêutico , Hemorragia Pós-Operatória/induzido quimicamente , Antagonistas do Receptor Purinérgico P2Y/uso terapêutico , Síndrome Coronariana Aguda/cirurgia , Monofosfato de Adenosina/efeitos adversos , Monofosfato de Adenosina/uso terapêutico , Adulto , Idoso , Idoso de 80 Anos ou mais , Doença da Artéria Coronariana/cirurgia , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ativação Plaquetária/efeitos dos fármacos , Antagonistas do Receptor Purinérgico P2Y/efeitos adversos , Stents , Tienopiridinas/administração & dosagem , Trombose/prevenção & controle
14.
J Interv Cardiol ; 24(6): 505-13, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-21919955

RESUMO

BACKGROUND: Higher rates of adverse cardiac events have been observed in patients with small vessel disease. Therefore, we compared an everolimus-eluting stent (EES) to a paclitaxel-eluting stent (PES) for treatment of small (reference vessel diameter: RVD <2.5 mm) and larger vessels (≥2.5 mm) in a pooled analysis from the SPIRIT III (n = 1,002) and SPIRIT IV (n = 3,687) trials (randomized 2:1, EES vs. PES). METHODS: Data of 4,689 total patients were pooled for a patient level analysis. Lesion length, RVD, and percent diabetics were matched between stent types. EES versus PES performance was evaluated at 1 year in patients with small (n = 1,019) and larger vessels (n = 2,586) who had a single lesion treated. RESULTS: Mean RVD assessed by quantitative coronary angiography in patients with small vessels was 2.24 ± 0.19 and 2.25 ± 0.20 mm in the EES and PES groups, respectively. At 1 year, EES compared to PES in small vessel patients significantly reduced major adverse cardiac events (4.5% vs. 7.9%, P = 0.04), target lesion failure (4.4% vs. 7.9%, P = 0.03), target lesion revascularization (2.4% vs. 5.5%, P = 0.02), and stent thrombosis (0.2% vs. 1.2%, P = 0.04). Relative benefits of EES versus PES were comparable in small and larger vessels (P interaction > 0.05), although the absolute benefits were greater in patients with small vessel disease. CONCLUSION: In high-risk patients requiring percutaneous coronary intervention in small coronary arteries, EES results in significantly improved 1-year rates of event-free survival compared to PES, with evidence present for both enhanced safety and efficacy.


Assuntos
Angioplastia Coronária com Balão , Antineoplásicos Fitogênicos/uso terapêutico , Reestenose Coronária/prevenção & controle , Stents Farmacológicos , Imunossupressores/uso terapêutico , Paclitaxel/uso terapêutico , Sirolimo/análogos & derivados , Antineoplásicos Fitogênicos/administração & dosagem , Angiografia Coronária , Reestenose Coronária/terapia , Everolimo , Feminino , Humanos , Imunossupressores/administração & dosagem , Masculino , Pessoa de Meia-Idade , Paclitaxel/administração & dosagem , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/uso terapêutico , Estatística como Assunto
15.
Circ J ; 75(5): 1120-9, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21467655

RESUMO

BACKGROUND: The long-term impact of treating de novo coronary lesions in native vessels and challenging small vessel and long lesion subsets with TAXUS Liberté stents is unknown. This report examines the 3-year efficacy and safety from the TAXUS ATLAS program. METHODS AND RESULTS: TAXUS ATLAS WH, Small Vessel, and Long Lesion are non-randomized studies comparing TAXUS Liberté (n = 871), TAXUS Liberté 2.25 mm (n = 261), and TAXUS Liberté 38 mm (n = 150) stents, respectively, to case-matched TAXUS Express historical controls. TAXUS Liberté demonstrated comparable 3-year rates of major adverse cardiac events (19.0% vs. 20.2%, P = 0.51) in de novo lesions, reduced target lesion revascularization (TLR, 10.0% vs. 22.1%, P = 0.008) in small vessels, and reduced myocardial infarction (MI, 2.9% vs. 10.4%; P = 0.01) and stent thrombosis (ST, 0.0% vs. 3.9%, P = 0.03) in long lesions vs. TAXUS Express. After propensity score adjustment, no statistically significant effect of TAXUS Liberté on TLR (9.7% vs. 16.9%, P = 0.12) in small vessels or MI (2.9% vs. 7.9%, P = 0.05) in long lesions was noted, although reduced ST (0.0% vs. 2.7%, P = 0.02) remained in long lesions. Multivariate analyses demonstrated that TAXUS Liberté treatment significantly reduced TLR by 66% in small vessels, and MI by 75% in long lesions, vs. TAXUS Express. CONCLUSIONS: TAXUS Liberté suggests durable 3-year effectiveness in reducing restenosis and improved clinical outcomes in small vessels and long lesions compared with TAXUS Express.


Assuntos
Stents , Humanos , Taxus
17.
J Interv Cardiol ; 23(1): 26-32, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-20040005

RESUMO

BACKGROUND: Drug-eluting stents (DES) are widely used for treatment of coronary artery disease with benefit of reduced restenosis compared to bare metal stents. The XIENCE VEverolimus Eluting Coronary Stent System is a second-generation DES system for better deliverability while maintaining safety and efficacy profiles. The present pharmacokinetic sub-study from the SPIRIT III Randomized and Controlled Trial (RCT) was to evaluate systemic exposure of patients to everolimus and to further demonstrate safety following implantation of XIENCE Vstents with everolimus doses ranging from 53 to 181 microg. METHODS AND RESULTS: Drug concentrations in whole blood were determined at multiple time points using a validated analytical method with a limit of quantification of 0.1 ng/mL. Individual C(max) ranged from 0.17 to 2.40 ng/mL and occurred between 0.07 and 1.88 hours across all dose levels. Both mean and individual C(max) values were below the trough blood concentrations of everolimus (Certican) for inhibition of organ transplant rejection. The last time point at which drug concentrations could be quantified ranged from 12 to 168 hours postimplantation in individual patients. In most cases, the blood levels dropped below the limit of quantification after 72 hours. CONCLUSIONS: This study confirms that the XIENCE Vstent causes a limited and systemic exposure to everolimus. The presumed localized and efficient delivery of everolimus to target vessels coupled with limited and transient systemic drug exposure contributes to the safety and effectiveness of the XIENCE VEECSS in patients of SPIRIT III RCT for longer than 2 years.


Assuntos
Reestenose Coronária/tratamento farmacológico , Stents Farmacológicos/efeitos adversos , Imunossupressores/farmacocinética , Sirolimo/análogos & derivados , Idoso , Análise de Variância , Área Sob a Curva , Intervalos de Confiança , Stents Farmacológicos/estatística & dados numéricos , Everolimo , Feminino , Humanos , Imunossupressores/uso terapêutico , Modelos Lineares , Masculino , Pessoa de Meia-Idade , Sirolimo/farmacocinética , Sirolimo/uso terapêutico
18.
Am J Cardiol ; 101(9): 1263-8, 2008 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-18435955

RESUMO

Diabetes mellitus is a strong predictor of in-stent restenosis after bare-metal stent placement because of exaggerated intimal hyperplasia (IH). In this study, serial intravascular ultrasound was used to evaluate the effects of polymer-based, paclitaxel-eluting stents (PES) on in-stent neointima formation in patients with and without diabetes. A volumetric IVUS meta-analysis of 956 patients randomized to PES or bare-metal stents in the TAXUS IV (n=268), TAXUS V (n=509), and TAXUS VI (n=179) trials was performed. Diabetes was present in 273 of the 956 patients (28.6%). Stent, luminal, and IH areas were measured every millimeter within the stent, and volumes, percentage IH (%IH), and neointima-free stent length were calculated. Patients with diabetes treated with bare-metal stents had greater IH volumes (78.9 vs 61.2 mm3, p=0.0095) and %IH (34.9% vs 30.1%, p=0.0186) compared with those without diabetes. However, patients with diabetes treated with PES had similar median IH volume (22.8 vs 16.3 mm3, p=0.35) and median %IH (9.1% vs 9.2%, p=0.27) compared with those without diabetes and significantly less IH volume and %IH than after bare-metal stent implantation (p<0.0001 for the 2 comparisons). In conclusion, serial volumetric IVUS analysis showed that treatment with PES neutralizes the propensity of patients with diabetes to develop greater IH, such that patients with and without diabetes treated with PES have similar vascular responses and restenosis rates.


Assuntos
Doença das Coronárias/terapia , Diabetes Mellitus , Stents Farmacológicos , Paclitaxel/administração & dosagem , Stents , Ultrassonografia de Intervenção , Distribuição de Qui-Quadrado , Angiografia Coronária , Doença das Coronárias/diagnóstico por imagem , Vasos Coronários/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ensaios Clínicos Controlados Aleatórios como Assunto , Estatísticas não Paramétricas , Túnica Íntima/diagnóstico por imagem , Túnica Íntima/efeitos dos fármacos
19.
Catheter Cardiovasc Interv ; 72(6): 771-80, 2008 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19006244

RESUMO

BACKGROUND: Recanalization of coronary chronic total occlusions (CTOs) remains a clinical challenge, particularly when standard guidewire attempts fail. OBJECTIVES: We sought to determine the safety and efficacy of a novel method that used high-frequency (20 kHz) vibration to fragment occlusive fibrous tissue and facilitate guidewire crossing into the distal vessel. METHODS: A total of 125 patients with CTO, who failed at attempts of conventional guidewire recanalization after more than 5 min of fluoroscopy time, were enrolled in the study. The primary efficacy endpoint was the advancement of the CROSSER catheter through the occlusion and attainment of coronary guidewire positioning in the distal coronary lumen. The primary safety endpoint was the occurrence of death, myocardial infarction, clinical perforation, or target vessel revascularization within the first 30 days. RESULTS: The average fluoroscopy time while delivering the CROSSER catheter was 12.4 min. CROSSER-assisted guidewire recanalization was achieved in 76 (60.8%) procedures and a final diameter stenosis <50% was obtained in 68 (54.4%) of cases. Major adverse events occurred in 11 (8.8%) patients, lower than the predefined objective performance criteria. Angina frequency and quality of life were improved in patients with successful guidewire recanalization. CONCLUSIONS: We conclude that high-frequency vibration using the CROSSER catheter is a safe and effective therapy for patients with CTO, which are refractory to standard guidewire recanalization.


Assuntos
Angioplastia Coronária com Balão/métodos , Oclusão Coronária/terapia , Estenose Coronária/terapia , Vibração/uso terapêutico , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/etiologia , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Qualidade de Vida , Inquéritos e Questionários , Fatores de Tempo , Falha de Tratamento , Estados Unidos
20.
Cardiovasc Revasc Med ; 18(7): 475-481, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28923692

RESUMO

BACKGROUND: BioFreedom is a polymer- and carrier-free drug-coated stent that delivers Biolimus A9 to the vessel wall. Our purpose was to evaluate the efficacy and safety of this DCS in patients with short-duration dual antiplatelet therapy. METHODS: The BioFreedom US IDE feasibility trial was a single-arm, open-label, prospective study of patients requiring stenting of de novo lesions. Patients received 3 months of DAPT, repeat angiography at 9 months, and clinical follow-up at multiple intervals. A subgroup also underwent intravascular ultrasound (IVUS) interrogation. The primary safety end point was major adverse cardiac events, defined as a composite of cardiac death, myocardial infarction, target lesion revascularization, or stent thrombosis. The primary efficacy end point, in-stent late lumen loss at 9 months, was compared with a historical control from a first-generation paclitaxel-eluting stent. RESULTS: A total of 72 patients from 10 sites received BioFreedom DCS implanted in 83 de novo lesions. At 9 months, the incidence of composite MACE was 8.4%, and TLR was 1.5%. Short DAPT was safe without occurrence of stent thrombosis. The primary end point of LLL was 0.32±0.53 mm. Paired IVUS analyses comparing postprocedural with 9-month measurements showed low in-stent neointimal volume obstruction (5.39±5.28%) and low neointimal hyperplasia (7.43±8.04 mm3). CONCLUSIONS: This study's angiography and IVUS assessments demonstrated that the BioFreedom DCS has anti-restenotic efficacy similar to first-generation DES. In the absence of concerning safety signals, this DCS should be considered effective and safe for patients who require a shorter duration of DAPT.


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Angiografia Coronária , Doença da Artéria Coronariana/terapia , Vasos Coronários/diagnóstico por imagem , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/análogos & derivados , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Reestenose Coronária/diagnóstico por imagem , Reestenose Coronária/etiologia , Reestenose Coronária/prevenção & controle , Esquema de Medicação , Quimioterapia Combinada , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Inibidores da Agregação Plaquetária/administração & dosagem , Valor Preditivo dos Testes , Estudos Prospectivos , Desenho de Prótese , Fatores de Risco , Sirolimo/administração & dosagem , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA