Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 50
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Womens Health ; 22(1): 290, 2022 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-35836228

RESUMO

BACKGROUND: The three-dimensional (3D) printing technology has remarkable potential as an auxiliary tool for representing anatomical structures, facilitating diagnosis and therapy, and enhancing training and teaching in the medical field. As the most available diagnostic tool and it is routinely used as the first approach in diagnosis of the uterine anomalies, 3D transvaginal ultrasonography (3D-TVS) has been proposed as non-invasive "gold standard" approach for these malformations due to high diagnostic accuracy. Despite holding promise of manufacturing 3D printed models based on 3D-TVS data, relevant reports about 3D-TVS derived gynecological 3D printing haven't been reported to the best of our knowledge. We found an opportunity to explore the feasibility of building 3D printed models for the abnormal uterus based on the data acquired by 3D-TVS. METHODS: The women suspected with congenital uterine anomalies (CUAs) were enrolled in the study. The diagnose of CUAs were made by 3D-TVS scanning and further confirmed under the hysteroscopy examination. One volunteer with normal uterus was enrolled as control. All subjects underwent 3D-TVS scanning for 3D printing data collection. Acquired images were stored and extracted as DICOM files, then processed by professional software to portray and model the boundary of the uterine inner and outer walls separately. After the computer 3D models were constructed, the data were saved and output as STL files for further surface restoration and smoothing. The colors of endometrium and uterine body were specified, respectively, in the print preview mode. Then the uncured photosensitive resin was cleaned and polished to obtain a smooth and transparent solid model after printed models were cooled down. RESULTS: 3D printing models of normal uterus, incomplete septate uterus, complete septate uterus, uterus didelphys and unicornuate uterus were produced on ultrasonographic data of 3D-TVS. CONCLUSIONS: Our research and practice made the first try in modeling CUAs successfully based on ultrasonographic data entirely, verifying that it's a feasible way to build 3D printed models of high-quality through 3D-TVS scanning.


Assuntos
Impressão Tridimensional , Útero , Feminino , Humanos , Imageamento Tridimensional/métodos , Estudos Prospectivos , Ultrassonografia/métodos , Anormalidades Urogenitais , Útero/anormalidades , Útero/diagnóstico por imagem
2.
Acta Clin Croat ; 61(1): 138-144, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36398079

RESUMO

Three-dimensional printed polyetheretherketone (PEEK) extravascular stent was applied to treat a 14-year-old boy with nutcracker syndrome. Digital subtraction angiography revealed a segment of the left renal vein (LRV) with reduced contrast filling immediately before its inflow into the inferior vena cava, and high-pressure gradient. The three-dimensional reconstruction model demonstrated that the LRV and the duodenum were contracted at the aortomesenteric angle, resulting in LRV compression from the abnormal high-level duodenal compartment. When duodenum courses between the abdominal aorta and superior mesenteric artery (duodenal interposition), the LRV entrapment occurs even at <90 aortomesenteric degrees. Three-dimensional printed PEEK extravascular stent was chosen to elevate the superior mesenteric artery and lower the duodenum position, thus relieving LRV compression. This extravascular application has significant advantages over open surgery, endovascular stenting and artificial vessel procedures with expanded polytetrafluoroethylene. It provides better cellular vitality by ensuring soft tissue proliferation. By reducing external acceleration and centrifugal force, a three-dimensional printed PEEK extravascular stent reduces adverse side effects. Such a stent has a distinctive personalized design, good stiffness, and durability that allows blood vessel growth, preventing stent migration and thrombosis. Therefore, it is suitable for both adult and pediatric patients. According to the abdominal ultrasound and multi-slice computed tomography scan, the postoperative follow-up results were satisfactory one year after surgery. The patient felt well, the blood flow in the LRV was not obstructed, and the blood flow velocity was average. The external stent was in place.


Assuntos
Síndrome do Quebra-Nozes , Adulto , Masculino , Humanos , Adolescente , Criança , Síndrome do Quebra-Nozes/complicações , Síndrome do Quebra-Nozes/cirurgia , Stents/efeitos adversos , Veias Renais/cirurgia , Cetonas , Polietilenoglicóis , Impressão Tridimensional
3.
Clin Exp Rheumatol ; 35 Suppl 103(1): 134-138, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28466805

RESUMO

OBJECTIVES: The aim of this study was to evaluate the aortic stiffness (AS) in young female patients with Takayasu's arteritis (TAK) and comparable controls by measuring carotid-femoral PWV (PWVcf) using echocardiography with pulse wave Doppler. The clinical feasibility and reproducibility of this echocardiographic method were also investigated. METHODS: Twenty-five TAK female patients (mean age 28.3±6.2 years) and 25 strictly matched healthy controls were included according to rigorous inclusion and exclusion criteria. The PWVcf of all subjects were measured by echocardiography based on the principle that PWVcf could be calculated by pulse wave spreading distance divided by the transmit time. Reproducibility of the echocardiographic measured PWVcf were performed randomly in 15 TAK patients and 15 healthy controls. RESULTS: The patients with TAK had a higher PWVcf value measured by echocardiography, compared with healthy controls (8.37±2.23 vs. 6.46±1.15 m/s; p<0.001). The echocardiographic measured PWVcf was significantly dependent on the TAK (p=0.003), age (p=0.032) and pulse pressure (p=0.025). PWVcf did not correlate with the echocardiographic measured cardiac systolic and diastolic parameters and the laboratory variables in TAK patients (p>0.05 for all). The intra- and inter-observer coefficients of variation were low and the Bland-Altman plots indicated a satisfactory reproducibility. CONCLUSIONS: Our results indicated that AS in female patients with TAK is increased, which may predict a higher cardiovascular risk. This manifestation is prior to the impairment of cardiac diastolic function. This elevated AS can be detected by echocardiographic measured PWVcf with a good reproducibility.


Assuntos
Aorta/diagnóstico por imagem , Ecocardiografia Doppler de Pulso , Arterite de Takayasu/diagnóstico por imagem , Rigidez Vascular , Adulto , Aorta/fisiopatologia , Estudos de Casos e Controles , Estudos Transversais , Feminino , Humanos , Valor Preditivo dos Testes , Análise de Onda de Pulso , Reprodutibilidade dos Testes , Fatores Sexuais , Arterite de Takayasu/fisiopatologia , Adulto Jovem
4.
J Ultrasound Med ; 35(3): 547-52, 2016 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-26921087

RESUMO

OBJECTIVES: To investigate the capacity of blood storage of certain large arteries during diastole, we first studied the ascending aorta by echocardiography. The concept of the blood supply fraction of the ascending aorta was then introduced to evaluate elastic retraction of the ascending aortic wall and determine its role in diagnosing early atherosclerosis of the ascending aorta. METHODS: First, we enrolled 120 healthy volunteers and divided them into 3 groups according to age: 20 to 35 years (B1 group), 36 to 50 years (B2 group), and 51 to 65 years (B3 group); there were 40 volunteers in each group. We used echocardiography to measure the blood supply fraction in each volunteer and compared the results for each group. Then we enrolled 40 patients (51-65 years) with early atherosclerosis of the ascending aorta, measured the blood supply fraction of each, and compared the results with the B3 group. RESULTS: The mean blood supply fractions ± SD in the B1, B2, and B3 groups were 21.75% ± 1.53%, 20.76% ± 1.62%, and 18.44% ± 1.19%, respectively. The fraction in the B3 group was significantly lower than those in the B1 and B2 groups (P < .01). The fraction in the patients with early atherosclerosis was 14.92% ± 1.01%, which was obviously lower than that in the B3 group (P < .01). CONCLUSIONS: The blood supply fraction of the ascending aorta decreases with age, and it could be used as a parameter for diagnosis of early atherosclerosis of the ascending aorta.


Assuntos
Aorta/fisiopatologia , Doenças da Aorta/diagnóstico por imagem , Doenças da Aorta/fisiopatologia , Aterosclerose/diagnóstico por imagem , Aterosclerose/fisiopatologia , Velocidade do Fluxo Sanguíneo , Adulto , Envelhecimento , Aorta/diagnóstico por imagem , Diagnóstico Precoce , Ecocardiografia/métodos , Feminino , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Masculino , Pessoa de Meia-Idade , Imagem de Perfusão/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Adulto Jovem
5.
Cardiovasc Diabetol ; 13: 39, 2014 Feb 10.
Artigo em Inglês | MEDLINE | ID: mdl-24506844

RESUMO

BACKGROUND: Type 2 diabetes is one of the most common causes of cardiovascular disease as it causes arterial stiffness changes. The purpose of this study is to characterize, in vivo, carotid arterial structural and functional changes by applying radio frequency and X-strain ultrasound techniques. METHODS: Ninety-one subjects were assigned into two groups; a diabetes group and a control group. Structural and functional changes in the common carotid arterial wall were investigated by quality intima-media thickness (QIMT), quality arterial stiffness (QAS), and X-strain analysis with a Mylab Twice ultrasound instrument. The relationships among variables between the two groups were analyzed in this study. RESULTS: There was no significant difference in carotid IMT (626.5 ± 169.1 µm vs. 568.5 ± 122.6 µm, P = 0.1506) between two groups. Pulse wave velocity (PWV) and stiffness index (ß) were remarkably greater (8.388 ± 3.254 m/s vs. 7.269 ± 1.332 m/s; 12.51 ± 14.16 vs.9.279 ± 2.871), while compliance coefficient (CC) decreased significantly in the diabetes group (0.802 ± 0.3094 mm2/Kpa vs. 0.968 ± 0.3992 mm2/Kpa) (P < 0.05). The displacement difference of radial (RD-D), longitudinal (LD-D) and rotation (ROT-D) directions were significantly different between two groups' comparison (P = 0.0212, P = 0.0235 and P = 0.0072, respectively). The time of circumferential peak strain difference (CS-DT) and the time of radial peak strain rate (RSR-T) were found to be significantly different between the two groups (341.9 ± 77.56 ms vs. 369.0 ± 78.26 ms, P = 0.0494; 142.7 ± 22.43 ms vs. 136.2 ± 30.70 ms, P = 0.0474). CS-TD and RSR-T were also found to be positively correlated with CC value (r = 0.3908, P < 0.005 and r = 0.3027, P = 0.0326, respectively). Finally, PWV was negatively correlated with CC with (r = -0.6177, P < 0.001). CONCLUSIONS: In type 2 diabetes, the functional changes in CCA can be identified using the methods presented in this article earlier than the structural changes. Arterial stiffness values provided by QAS and X-strain analysis can be used as indicators of CCA functional lesions in patients with type 2 diabetes.


Assuntos
Artéria Carótida Primitiva/patologia , Espessura Intima-Media Carotídea/normas , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/fisiopatologia , Elasticidade/fisiologia , Rigidez Vascular/fisiologia , Adulto , Idoso , Velocidade do Fluxo Sanguíneo/fisiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
6.
BMC Pregnancy Childbirth ; 14: 113, 2014 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-24666973

RESUMO

BACKGROUND: Cardiovascular adaptions, such as cardiac and uterine spiral arterial remodeling, and aortic arterial stiffening during pregnancy have been extensively investigated, while the interactions between the elastic artery and the left ventricle are poorly understood. This study was to evaluate the cardiac-arterial coupling in both normal pregnancy and preeclampsia using ultrasound techniques. METHODS: Twenty-three preeclamptic women with no antihypertensive treatment prior to admission, and 40 age- (27.2 ± 3.0 y vs. 29.1 ± 5.7 y, p = 0.0805) and gestational week- (35.6 ± 3.4 wk vs. 34.8 ± 3.6 wk, p = 0.3573) matched normotensive pregnant women were included. All women signed informed consent. All were nulliparas, had singleton pregnancies, and had no other risk factors for arterial stiffening. Carotid and cardiac ultrasound was performed using a MylabTwice ultrasound unit (Esaote, Italy). Cardiac and carotid remodeling and their associations were analyzed. Left ventriculo-carotid coupling was characterized by the ratio between the arterial elastance (Ea) and the left ventricular systolic elastance (Ees). Follow-up study was performed 16-20 months after parturition. RESULTS: Left ventricular and carotid arterial remodeling was seen more frequently in preeclamptic women than in normal pregnant controls (96% vs. 40%, 82% vs. 48%, both p < 0.0001). The relative carotid arterial wall thickness showed no significant difference between the two groups. However, the carotid cross-sectional area, a surrogate for carotid arterial mass, was significantly greater in preeclampsia than that in normal controls (11.23 ± 0.17 mm2 vs. 8.58 ± 1.88 mm2, p < 0.00001). Carotid arterial stiffness and intima-media thickness correlated significantly with cardiac diastolic function parameters and blood pressures (p < 0.05). Both Ea and Ees were significantly greater in preeclampsia, compared with values in normal pregnant controls (Ea: 2.41 ± 0.57 mmHg/ml vs. 1.98 ± 0.46 mmHg/ml, p = 0.0005; Ees: 11.68 ± 9.51 m/s2 vs. 6.91 ± 6.13 m/s2, p = 0.002). However, there was no significant difference in the left ventriculo-carotid coupling index, Ea/Ees, between the two groups. Carotid remodeling persisted in both preeclamptic women and normal pregnant controls 16-20 months after parturition. CONCLUSIONS: Significant cardiac and carotid remodeling and similar left ventriculo-carotid coupling were observed in both preeclampsia and normal pregnancy. Carotid remodeling may persist postpartum. Further studies with larger populations are needed to confirm these findings.


Assuntos
Artéria Carótida Primitiva/diagnóstico por imagem , Ecocardiografia/métodos , Pré-Eclâmpsia/diagnóstico por imagem , Ultrassonografia Pré-Natal/métodos , Rigidez Vascular/fisiologia , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular , Adulto , Artéria Carótida Primitiva/fisiopatologia , Feminino , Seguimentos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/embriologia , Humanos , Recém-Nascido , Pré-Eclâmpsia/fisiopatologia , Gravidez , Resultado da Gravidez , Estudos Retrospectivos , Fatores de Tempo
7.
BMC Pregnancy Childbirth ; 13: 122, 2013 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-23710816

RESUMO

BACKGROUND: The adaption of elastic arteries to transient increase in hemodynamic load in normal pregnancy (NP) remains controversial. The purpose of this study was to investigate the NP carotid remodeling and regional arterial stiffness before and after parturition. METHODS: Fifty-one NP women and 30 age-matched non-pregnant women were included. All women underwent right common carotid artery (RCCA) measurements with MylabTwice ultrasound instrument (Esaote, Italy). Carotid intima-medial thickness (IMT), pulse wave velocity (PWV, m/s), distensibility coefficient (DC, 1/KPa), α, ß, augmentation index (AIx, %) and carotid arterial pressure were obtained by the newly developed ultrasound vascular wall tracking methods: automatic QAS (Quality Arterial Stiffness) and QIMT (Quality Intima-Medial Thickness) Follow up study was performed. RESULTS: Compared to the non-pregnant controls, the arterial pressures were significantly increased and RCCA diameter was significantly enlarged in late gestational NP women. Twenty months after parturition, carotid diameter, DC, AIx, PWV and arterial wall tension were significantly decreased and had no significant difference with those in non-pregnant controls. CONCLUSIONS: Carotid arterial remodeling and stiffening could be seen in the normal pregnant women, which seems to be a physiological adaption and could be recovered post partum. QIMT and QAS together could provide a comprehensive assessment of the maternal carotid arterial changes during pregnancy.


Assuntos
Adaptação Fisiológica , Artéria Carótida Primitiva/diagnóstico por imagem , Artéria Carótida Primitiva/fisiologia , Gravidez/fisiologia , Adulto , Pressão Sanguínea , Espessura Intima-Media Carotídea , Estudos de Casos e Controles , Feminino , Humanos , Segundo Trimestre da Gravidez , Terceiro Trimestre da Gravidez , Análise de Onda de Pulso , Rigidez Vascular , Adulto Jovem
8.
Nephrol Dial Transplant ; 27(12): 4422-9, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22561582

RESUMO

BACKGROUND: Multidirectional myocardial strain analysis can provide mechanistic insight into the ventricular systolic function and pathophysiology. The aim of this study was to assess the multidirectional systolic function of the left ventricle (LV) and its relationship to LV geometry in hemodialysis patients with preserved left ventricular ejection fraction (LVEF). METHODS: A total of 98 end-stage renal disease patients (age 46 ± 10 years, 60% men) with preserved LVEF (≥50%) on a maintenance hemodialysis program and 18 healthy volunteers were enrolled. The patients were divided into non-hypertrophic groups (classified as normal LV geometry and concentric remodeling) and hypertrophy groups (classified as eccentric and concentric hypertrophy) according to their LV geometries assessed from LV mass/height(2.7) and relative wall thickness in combination. Multidirectional strain analysis was performed by two-dimensional speckle tracking echocardiography. RESULTS: Myocardial systolic strain (longitudinal and circumferential) and stress-corrected midwall fraction shorting (sc-MWFS) were lower in the hypertrophy groups compared with non-hypertrophic groups. Longitudinal strain and strain rate were even lower in the concentric hypertrophy group than the eccentric hypertrophy group (-15.5 ± 2.2% versus -17.8 ± 2.6%, P = 0.001; -0.7 ± 0.2 versus -0.9 ± 0.2s(-1), P = 0.016). Impaired longitudinal strain correlated with higher LV mass index (LVMI), relative wall thickness, pre-dialysis systolic blood pressure (SBP), calcium-phosphate product and lower sc-MWFS (all P < 0.0001) and weakly correlated with higher interdialytic weight gain (P = 0.004). Using multivariate linear regression, the independent predictors of LV longitudinal strain were pre-dialysis SBP, LVMI, relative wall thickness and sc-MWFS. There were no differences in LVEF and myocardial function in radial direction among all groups. CONCLUSIONS: In hemodialysis patients with LV hypertrophy, myocardial function was impaired not only in longitudinal direction but also in circumferential direction despite preserved LVEF. Low longitudinal strain is related to LV hypertrophy, concentric geometry and pre-dialysis blood pressure.


Assuntos
Coração/fisiopatologia , Hipertrofia Ventricular Esquerda/fisiopatologia , Falência Renal Crônica/fisiopatologia , Volume Sistólico , Sístole , Adulto , Feminino , Humanos , Hipertrofia Ventricular Esquerda/complicações , Falência Renal Crônica/complicações , Falência Renal Crônica/terapia , Masculino , Pessoa de Meia-Idade , Diálise Renal
9.
Echocardiography ; 29(3): E67-8, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22118271

RESUMO

In this article, we describe a double-chambered left ventricle (LV) in a 37-year-old man. Its accessory chamber attached to the inferior and posterior wall of LV, and had normal systolic contraction without any regional wall motion abnormality. A double-chambered LV was suspected on echocardiography and confirmed by cardiac computed tomography scanning and cardiac magnet resonance imaging. Our aim is to accentuate the value of echocardiography in this rare anomaly


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração/anormalidades , Ventrículos do Coração/diagnóstico por imagem , Adulto , Humanos , Masculino
10.
J Ultrasound Med ; 31(9): 1421-7, 2012 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-22922622

RESUMO

OBJECTIVES: The purpose of this study was to explore the value of the transthoracic echocardiographic suprasternal view in the diagnosis of patent ductus arteriosus subtypes. METHODS: Sixty-five patients with a patent ductus arteriosus were examined using transthoracic echocardiographic suprasternal and parasternal views before ductus arteriosus closure. Diameters of the aortic and pulmonary sides of the ductus arteriosus were measured, and subtype diagnoses were made. The results were compared with those from digital subtraction angiography. RESULTS: The mean diameters ± SD of the aortic side of the ductus arteriosus were 8.31 ± 2.76, 10.87 ± 3.26, and 11.15 ± 3.29 for the parasternal view, the suprasternal view, and digital subtraction angiography, respectively, whereas the diameters of the pulmonary side were 5.69 ± 2.82, 5.75 ± 2.63, and 6.09 ± 2.78 mm. Of the 65 cases, 12, 19, and 19 were the funnel-type patent ductus arteriosus as evaluated with the parasternal view, the suprasternal view, and digital subtraction angiography. Detection on the parasternal view was lower than that on the suprasternal view (χ(2) = 5.14; P < .025). CONCLUSIONS: The diameter of the aortic side of a patent ductus arteriosus can be accurately detected on the superasternal view, which would be helpful for diagnosis of patent ductus arteriosus subtypes.


Assuntos
Permeabilidade do Canal Arterial/diagnóstico por imagem , Ecocardiografia/métodos , Adolescente , Adulto , Idoso , Angiografia Digital , Distribuição de Qui-Quadrado , Criança , Pré-Escolar , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
11.
Heliyon ; 8(12): e11868, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36561689

RESUMO

Background: We present the first case report of the treatment of congenital vaginal atresia by 3D-printed patient-specific vaginal scaffold from China. Case presentation: A 17-year-old female patient was referred to our department for treatment of congenital vaginal atresia and complications arising from previous failed operations. Pelvic examination was conducted to understand the morphological characteristics and severity of stenosis, and based on which we designed our prototypes of vaginal scaffold using software UG NX10.0. We finally obtained our patient-specific mold, which was 50 mm in length, 28 mm in diameter, 2 mm of thickness with a whole weight of 7.6 g, and it was made of polycaprolactone. After removing scar tissues caused by vaginal stenosis, an 8 cm long artificial tunnel was created, and then the polycaprolactone (PCL) vaginal mold was placed and sutured. The patient had no discomfort after surgery and was discharged 3 days after the surgery. Follow-up for 1 year after surgery, through hysteroscopy and colposcopy, it was found that the cervix was smooth, the vaginal wall was covered with stratified squamous epithelium, and the vaginal wall was soft and lubricated, which was close to a normal vagina. The incompletely absorbed mold was taken out one year after the operation. Hysteroscopy and colposcopy were performed one year and two years after the mold was taken out. The vagina was unobstructed and the length was about 12 cm. The appearance of the vaginal wrinkles was normal. The patient's quality of sexual life was good. Conclusion: Our team tried to treat congenital vaginal atresia by 3D-printed patient-specific vaginal scaffold, which can effectively reduce patient complications and reduce patient pain. Through long-term follow-up, we found that this technique has achieved favorable results and improved the patient's quality of sexual life.

12.
BMC Gastroenterol ; 11: 84, 2011 Jul 19.
Artigo em Inglês | MEDLINE | ID: mdl-21767412

RESUMO

BACKGROUND: Abnormality of hepatic vein (HV) waveforms evaluated by Doppler ultrasonography has been widely studied in patients with chronic liver disease. We investigated the correlation between changes in HV waveforms and portal vein velocity (PVVel), the hepatic artery pulsatility index (HAPI), and also the extent of abnormal Doppler HV waveforms expressed as damping index (DI), severity of portal hypertension expressed as Child-Pugh scores and portal pressure (PP) measured directly from patients with portal hypertension (PHT) to evaluate the indicative value of abnormal HV waveforms and discuss the cause of abnormal HV waveform. METHODS: Sixty patients who had been diagnosed with PHT and accepted surgical therapy of portosystemic shunts were investigated. PP was measured intraoperatively. Thirty healthy volunteers with no history of chronic liver disease were enrolled as the control group. HV waveforms were categorized as triphasic, biphasic or monophasic. DI was compared as the quantitative indicator of abnormal HV waveforms. Another two Doppler parameters, PVVel and HAPI were also measured. These Doppler features were compared with PP, Child-Pugh scores and histological changes assessed by liver biopsy. RESULTS: In the patient group, the Doppler flow waveforms in the middle HV were triphasic in 31.6%, biphasic in 46.7%, and monophasic in 21.6% of subjects. These figures were 86.7%, 10.0%, and 3.3%, respectively, in healthy subjects. With the flattening of HV waveforms, the HAPI increased significantly (r = 00.438, p < 0.0001), whereas PVVel decreased significantly (r = -0.44, p <0.0001). Blood flow parameters, HAPI, PVVel and HV-waveform changes showed no significant correlations with Child-Pugh scores. The latter showed a significant correlation with PP (r = 0.589, p = 0.044). Changes of HV waveform and DI significantly correlated with PP (r = 0.579, r = 0.473, p <0.0001), and significant correlation between DI and Child-Pugh scores was observed (r = 0.411, p = 0.001). PP was significantly different with respect to nodule size (p < 0.05), but HV-waveform changes were not significantly correlated with pathological changes. CONCLUSION: In patients with PHT, a monophasic HV waveform indicates higher portal pressure. Furthermore, quantitative indicator DI can reflect both higher portal pressure and more severe liver dysfunction. Flattening of HV waveforms accompanied by an increase in the HAPI and decrease in PVVel support the hypothesis that histological changes reducing HV compliance be the cause of abnormality of Doppler HV waveforms from the hemodynamic angle.


Assuntos
Artéria Hepática/fisiologia , Veias Hepáticas/fisiologia , Hipertensão Portal/fisiopatologia , Pressão na Veia Porta/fisiologia , Veia Porta/fisiologia , Ultrassonografia Doppler , Adulto , Velocidade do Fluxo Sanguíneo , Estudos de Casos e Controles , Feminino , Humanos , Hipertensão Portal/cirurgia , Circulação Hepática/fisiologia , Masculino , Pessoa de Meia-Idade , Adulto Jovem
13.
Heart Vessels ; 26(2): 214-21, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21174209

RESUMO

Our aim was to evaluate the effects of sympathetic excitation and elevation of blood pressure on mechanical properties of common carotid and femoral arteries by wave intensity analysis (WIA). The diameters and arterial stiffness parameters of right common carotid artery (RCCA) and right common femoral artery (RCFA) in healthy young men were measured by WIA at baseline and during cold pressor test (CPT). In addition, the blood pressure and heart rate were recorded simultaneously. The heart rates and blood pressures increased during CPT compared with baseline, while the pulse pressures remained unchanged. The diameters of RCCA increased slightly, while those of RCFA did not change. The Peterson's pressure modulus (Ep), augment index (AI), and pulse wave velocity from ß (PWVß) increased obviously, while arterial compliance (AC) decreased with no change in stiffness index (ß) of both arteries during CPT when compared with baseline. There was an obvious increase in pulse wave velocity from wave intensity (PWV_WI) of RCCA, while the PWV_WI of RCFA showed no significant change during CPT. The sympathetic nervous system exerts a more marked tonic restraint on RCFA than on RCCA. The Ep, AC, AI, PWVß of RCCA, and RCFA are much affected by variations in blood pressure and sympathetic status, while the ß of both arteries are less vulnerable to these factors and are more reliable in reflecting the actual arterial stiffness; The PWV_WI appears to be suitable only for evaluating the stiffness of RCCA instead of RCFA.


Assuntos
Artéria Carótida Primitiva/inervação , Temperatura Baixa , Artéria Femoral/inervação , Hemodinâmica , Sistema Nervoso Simpático/fisiologia , Sensação Térmica , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Artéria Carótida Primitiva/diagnóstico por imagem , China , Complacência (Medida de Distensibilidade) , Módulo de Elasticidade , Artéria Femoral/diagnóstico por imagem , Frequência Cardíaca , Humanos , Masculino , Variações Dependentes do Observador , Valor Preditivo dos Testes , Fluxo Pulsátil , Valores de Referência , Reprodutibilidade dos Testes , Ultrassonografia Doppler em Cores , Adulto Jovem
14.
Transl Lung Cancer Res ; 10(11): 4057-4083, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35004239

RESUMO

Chest wall tumors are a relatively uncommon disease in clinical practice. Most of the published studies about chest wall tumors are usually single-center retrospective studies, involving few patients. Therefore, evidences regarding clinical conclusions about chest wall tumors are lacking, and some controversial issues have still to be agreed upon. In January 2019, 73 experts in thoracic surgery, plastic surgery, science, and engineering jointly released the Chinese Expert Consensus on Chest Wall Tumor Resection and Chest Wall Reconstruction (2018 edition). After that, numerous experts put forward new perspectives on some academic issues in this version of the consensus, pointing out the necessity to further discuss the points of contention. Thus, we conducted a survey through the administration of a questionnaire among 85 experts in the world. Consensus has been reached on some major points as follows. (I) Wide excision should be performed for desmoid tumor (DT) of chest wall. After excluding the distant metastasis by multi-disciplinary team, solitary sternal plasmacytoma can be treated with extensive resection and adjuvant radiotherapy. (II) Wide excision with above 2 cm margin distance should be attempted to obtain R0 resection margin for chest wall tumor unless the tumor involves vital organs or structures, including the great vessels, heart, trachea, joints, and spine. (III) For patients with chest wall tumors undergoing unplanned excision (UE) for the first time, it is necessary to carry out wide excision as soon as possible within 1-3 months following the previous surgery. (IV) Current Tumor Node Metastasis staging criteria (American Joint Committee on Cancer) of bone tumor and soft tissue sarcoma are not suitable for chest wall sarcomas. (V) It is necessary to use rigid implants for chest wall reconstruction once the maximum diameter of the chest wall defect exceeds 5 cm in adults and adolescents. (VI) For non-small cell lung cancer (NSCLC) invading the chest wall, wide excision with neoadjuvant and/or adjuvant therapy are recommended for patients with stage T3-4N0-1M0. As clear guidelines are lacking, these consensus statements on controversial issues on chest wall tumors and resection could possibly serve as further guidance in clinical practice during the upcoming years.

15.
Artigo em Inglês | MEDLINE | ID: mdl-32719785

RESUMO

Minimally invasive options are safe and reliable alternatives for the treatment of nutcracker syndrome (NCS). After continued efforts, our team successfully devised a new and effective therapeutic method: 3D-printed extravascular stenting of the left renal vein. From December 2017 to May 2019, 28 patients (25 men and 3 women) from different parts of China between 18 and 37 years old (mean, 23.6 years) diagnosed with NCS were admitted for laparoscopic 3D-printed extravascular stenting treatment. The post-operative follow-up duration was 6-24 months (median, 16.3 months). Technical success of the operation was achieved in all patients. After treatment, the NCS symptoms all patients resolved or improved during the follow-up period, without relapse. Most symptoms, including macro-/microhematuria, proteinuria, and flank/abdominal pain, tended to resolve within 3-6 months after the surgery; other symptoms, such as left-sided varicocele, also showed varying degrees of improvement at different times post-operatively. Perioperative complications were noted in two patients, including transient and mild lymphatic leakage, without any adverse effects. All extravascular stents were visualized on computed tomography and Doppler ultrasound scans, and no migration or any side effects occurred during the entire follow-up period. Compared to endovascular stenting or polytetrafluoroethylene artificial vessel procedures, 3D-printed polyetheretherketone extravascular stenting has more advantages in terms of stent design and rigidity and approach rationality while successfully preventing stent migration and thrombosis. Therefore, this method may serve as an accurate and effective treatment for NCS patients.

16.
Ann Transl Med ; 8(4): 110, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32175403

RESUMO

BACKGROUND: Pectus excavatum (PE), one of the most common congenital chest wall deformities, is characterized by posterior depression of the sternum and lower costal cartilages. In this study, we demonstrated the application of flexible three-dimensional printing thoracic models for surgical approach planning of extrapleural Nuss procedure for patients with pectus excavatum. METHODS: Six patients with pectus excavatum were referred to our hospital for extrapleural Nuss procedure. Each patient's chest was reconstructed based on their computed tomography imaging data, and the three-dimensional (3D) thoracic model was manufactured with flexible material using 3D printing technique. The individual surgical approach and custom-made steel bars were designed and produced using these models. RESULTS: The surgical approach was evaluated by using the three-dimensional thoracic model. In all patients received extrapleural Nuss surgery, it has been proven the uniformity of repair efficacy in both models and patients. Moreover, an individualized and well-fitting steel bar can be fabricated once the surgical approach was confirmed. All the steel bars were loaded against the ribs rigorously and seamlessly. CONCLUSIONS: The flexible three-dimensional thoracic models were very helpful for the preoperative planning of extrapleural Nuss procedure.

17.
Echocardiography ; 26(2): 150-4, 2009 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19207993

RESUMO

OBJECTIVES: This study was aimed to explore respiratory variations of pulmonary venous flow and its clinical applications and the potential mechanism. METHODS: Pulsed-wave Doppler waveforms of right-upper pulmonary vein were recorded with Siemens Sequoia 512 in 20 healthy young subjects. Electrocardiogram and respiratory tracing were recorded simultaneously. The inspiratory and expiratory pulmonary venous peak flow velocities of S- and D-waves and their velocity-time integrals (VTIs) were acquired and averaged for five consecutive respiratory cycles, respectively. The ratios of velocities and the VTIs of S- to D-waves (S/D, VTIs/VTId) during inspiration and expiration were calculated. RESULTS: The velocity and VTI of S-wave did not vary significantly between inspiration and expiration (58.31 cm/sec +/- 9.22 cm/sec, 58.96 cm/sec +/- 7.79 cm/sec, P = 0.221; 16.29 cm +/- 2.59 cm, 16.54 cm +/- 2.18 cm, P = 0.090), while the velocity and VTI of D-wave increased significantly from inspiration to expiration (48.23 cm/sec +/- 8.32 cm/sec, 51.82 cm/sec +/- 8.72 cm/sec, P < 0.0001; 10.84 cm +/- 1.65 cm, 11.66 cm +/- 1.53 cm, P < 0.0001), resulting in significantly decreased ratios of the velocity and the VTI of S- to D-waves from inspiration to expiration (1.23 +/- 0.22, 1.17 +/- 0.27, P < 0.0001; 1.53 +/- 0.31, 1.43 +/- 0.22, P < 0.0001). CONCLUSIONS: Respiration has significant influence on pulmonary venous flow, which should be taken into account in evaluating left ventricular diastolic function when adopting pulmonary venous flow waveform, especially in diseased settings. The different anatomical positions of left and right heart relative to the thoracic cavity may account for the respiratory variations of pulmonary venous flow.


Assuntos
Ecocardiografia Doppler de Pulso/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/fisiologia , Mecânica Respiratória/fisiologia , Adulto , Velocidade do Fluxo Sanguíneo , Eletrocardiografia/métodos , Feminino , Humanos , Masculino , Monitorização Fisiológica/métodos , Monitorização Fisiológica/estatística & dados numéricos , Valores de Referência , Adulto Jovem
18.
Ann Thorac Surg ; 107(3): 921-928, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30403979

RESUMO

BACKGROUND: The purpose of this study is to use 3-dimensional printing (3DP) polyetheretherketone (PEEK) implants for skeletal reconstructions after wide excision of chest wall. 3DP PEEK implants were expected to provide a better physiological simulation than traditional ones because of a closer elastic modulus to cortical bone and similar biomechanical properties. METHODS: Eighteen patients (mean age 44.5 years), comprising 6 males and 12 females, underwent adequate radical wide excision for tumors and chest wall reconstruction using 3DP PEEK implants. Surgical data, which include patient demographic characteristics, implant preparation parameters, and preoperative and postoperative pulmonary function test results, were collected and analyzed. RESULTS: Ten patients with rib tumors and 8 patients with sternum tumors were selected for the study. The mean chest wall defect size was 173.6 ± 151.5 cm2 (range, 55 to 625 cm2). The mean weight of a single 3DP PEEK rib and sternum was 28 g and 104 g, respectively. The flexural and tensile strength of PEEK implants were 141 ± 7 MPa and 89 ± 3 MPa, respectively. Preoperative and postoperative pulmonary function tests revealed that mean forced vital capacity was from 2.79 ± 0.68 L to 2.40 ± 0.70 L with a reduction of 14.0% (p < 0.001). No side effects were observed 6 to 12 months after the operation. CONCLUSIONS: These findings suggest that 3DP PEEK implant is a safe and effective alternative in the reconstruction of chest wall defects. The pulmonary function of the patient may be preserved effectively after surgery.


Assuntos
Cetonas , Polietilenoglicóis , Impressão Tridimensional , Neoplasias Torácicas/cirurgia , Parede Torácica/cirurgia , Toracoplastia/métodos , Adolescente , Adulto , Idoso , Benzofenonas , Materiais Biocompatíveis , Desenho Assistido por Computador , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Polímeros , Tomografia por Emissão de Pósitrons , Desenho de Prótese , Estudos Retrospectivos , Neoplasias Torácicas/diagnóstico , Parede Torácica/diagnóstico por imagem , Adulto Jovem
19.
Chin Med J (Engl) ; 132(12): 1454-1460, 2019 Jun 20.
Artigo em Inglês | MEDLINE | ID: mdl-31205104

RESUMO

BACKGROUND: This study was designed to evaluate the clinical and radiographic outcomes of patients with nutcracker syndrome (NCS) who were treated with three-dimensional printing (3DP) extravascular titanium stents (EVTSs). The 3DP EVTS was expected to release the hypertension of the left renal vein (LRV) produced by its compression between the superior mesenteric artery (SMA) and the aorta without causing any complications. METHOD: The pre-operative kidney model of each patient was printed out to enable surgical planning. After that, the EVTS was designed based on the LRV's primitive physiologic structure using computer-aided design software, and each stent was printed out with a precision setting of 20 µm. Seventeen patients who had been suffering from NCS underwent laparoscopic 3DP EVTS placement. The surgical procedure was designed for the placement of EVTS, taking great care in positioning and fixing the stent. Surgical data, which included patient demographic characteristics as well as pre- and post-operative test results, were collected and analyzed. RESULTS: The mean duration of surgery was 75 ±â€Š9 min, and the mean blood loss was 20 ±â€Š5 mL. Computed tomography examinations revealed that the pre- and post-operative angle between the SMA and the aorta ranged from 18.7°â€Š±â€Š4.3° to 48.0°â€Š±â€Š8.8° (P < 0.05); in patients with left varicocele, the mean diameter of the left spermatic vein ranged from 3.7 ±â€Š0.5 to 1.3 ±â€Š0.2 mm (P < 0.05). Moreover, Doppler ultrasound examinations showed that the peak velocity of blood flow at the hilar area ranged from 12.4 ±â€Š3.3 to 18.5 ±â€Š3.4 cm/s (P < 0.05). No side effects were observed in the 24 to 42 months following surgery. CONCLUSION: The findings after 2 years of follow-up suggest that the 3DP EVTS is a safe and effective minimally invasive alternative for the treatment of NCS.


Assuntos
Síndrome do Quebra-Nozes/cirurgia , Stents , Titânio/química , Adolescente , Adulto , Feminino , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Impressão Tridimensional , Estudos Retrospectivos , Adulto Jovem
20.
Ultrasound Med Biol ; 34(2): 221-7, 2008 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-17964064

RESUMO

A rabbit model of acute thrombo-embolic pulmonary hypertension was developed by infusing self-thrombi into the right femoral vein and simultaneously measuring the pulmonary artery pressure via a right heart catheter and echocardiography. The model was used to explore the usefulness of an ultrasound-guided protocol. In the present study, acute thrombo-embolic pulmonary hypertension was produced in 25 of 30 healthy New Zealand rabbits; the success rate was 83%. A significant and positive correlation between the right ventricle-right atrial pressure gradient, an estimate of the pulmonary artery systolic pressure derived from tricuspid regurgitation and the pulmonary artery systolic pressure measured using the right heart catheter (r=0.765, P=0.002) was noted. During the process of establishing a rabbit model of acute thrombo-embolic pulmonary hypertension, it was demonstrated that echocardiography can be used to guide the right heart catheter to obtain pulmonary artery systolic pressure measurements, to quantify the tricuspid regurgitation jet to assess the pulmonary artery systolic pressure and to observe cardiac morphologic changes so as to evaluate cardiac function. Based on the present study, it is clear that echocardiography is valuable in improving the success rate of producing the animal model of acute thrombo-embolic pulmonary hypertension. This could ultimately facilitate preclinical research and clinical research in humans.


Assuntos
Hipertensão Pulmonar , Modelos Animais , Tromboembolia , Doença Aguda , Animais , Pressão Sanguínea , Cateterismo Cardíaco , Ecocardiografia/métodos , Feminino , Hipertensão Pulmonar/diagnóstico por imagem , Masculino , Artéria Pulmonar/fisiopatologia , Coelhos , Tromboembolia/diagnóstico por imagem , Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA