Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Express ; 31(7): 11805, 2023 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-37155807

RESUMO

An error on the part of the authors in drafting resulted in Eq. (3) being incorrect in the published paper [Opt. Express25, 20612 (2017)10.1364/OE.25.020612]. We present a corrected version of the equation. It should be noted that this does not affect the presented results or conclusions of the paper.

2.
Appl Opt ; 61(12): 3312-3318, 2022 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-35471426

RESUMO

We report the successful picosecond laser welding of AlSi and YAG. This material combination is of significant interest to the field of laser design and construction. Parameter maps are presented that demonstrate the impact of pulse energy and focal position on the resultant weld. Weld performance relevant to industrial applications is measured, i.e., shear strength, process yield, and absolute thermal resistance are presented.

3.
Appl Opt ; 59(16): 4988-4996, 2020 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-32543496

RESUMO

We investigate the impact of input pulse duration and peak power of a femtosecond laser on pulse broadening and propagation losses in selected hollow-core antiresonant fiber (HC-ARF). The mixed effects of strong self-phase modulation and relatively weak Raman scattering broaden the spectral width, which in turn causes a portion of the output spectrum to exceed the transmission band of the fiber, resulting in transmission losses. By designing and setting up a gas flow control system and a vacuum system, the nonlinear behavior of the fiber filled with different pressurized gases is investigated. The experimental results show that replacing the air molecules in the fiber core with argon can weaken pulse broadening and increase the transmittable peak power by 14 MW for a given 122 MW input, while a vacuum system can reduce the nonlinearity to a larger extent, therefore enhancing the transmission of HC-ARF by at least 26 MW.

4.
Opt Express ; 25(17): 20612-20621, 2017 Aug 21.
Artigo em Inglês | MEDLINE | ID: mdl-29041739

RESUMO

We present the results of measurements of resonant spectral bend loss using a novel apparatus in a series of hollow core anti-resonant optical fibers, important for their applications in the delivery of industrial power ultra-short laser pulses. The measured bend losses exhibit clear wavelength-bend diameter resonances. We demonstrate, in good agreement with theoretical analysis, that the sensitivity to bend diameter (in terms of minimum bend radii) is dependent on the ratio between cladding and core structure size. By decreasing the cladding capillary diameter: core diameter ratio from 0.70 to 0.43 the minimum bend diameter is decreased from >160 mm to ~15 mm at a wavelength of 800 nm. Furthermore it is demonstrated that the exact position of the loss bands is highly dependent on the orientation of the fiber structure with the bend plane.

5.
Appl Opt ; 56(16): 4873-4881, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-29047628

RESUMO

We report systematic analysis and comparison of ps-laser microwelding of industry relevant Al6082 parts to SiO2 and BK7. Parameter mapping of pulse energy and focal depth on the weld strength is presented. The welding process was found to be strongly dependent on the focal plane but has a large tolerance to variation in pulse energy. Accelerated lifetime tests by thermal cycling from -50° to +90°C are presented. Welds in Al6082-BK7 parts survive over the full temperature range where the ratio of thermal expansion coefficients is 3.4:1. Welds in Al6082-SiO2 parts (ratio 47.1:1) survive only a limited temperature range.

6.
Opt Express ; 23(14): 18645-57, 2015 Jul 13.
Artigo em Inglês | MEDLINE | ID: mdl-26191923

RESUMO

Previous reports of ultrafast laser welding of glass-to-glass have indicated that a pre-existing optical contact (or very close to) between the parts to be joined is essential. In this paper, the capability of picosecond laser welding to bridge micron-scale gaps is investigated, and successful welding, without cracking, of two glasses with a pre-existing gap of 3 µm is demonstrated. It is shown that the maximum gap that can be welded is not significantly affected by welding speeds, but is strongly dependent on the laser power and focal position relative to the interface between the materials. Five distinct types of material modification were observed over a range of different powers and surface separations, and a mechanism is proposed to explain the observations.

7.
Opt Express ; 23(21): 28104-5, 2015 Oct 19.
Artigo em Inglês | MEDLINE | ID: mdl-26480468

RESUMO

The results presented in Fig. 8 were incorrect; the growth in the weld structure presented was due to the laser taking 3 ms to reach full power. Here we present a corrected version of the figure and associated discussion. It should be noted that this affects only the exact number of pulses required to form the weld structure and some of the low pulse number observations. This does not therefore affect the theory presented in the paper. In addition Fig. 9 and Fig. 10 were reversed in the published version. The correct figures are presented below.

8.
Opt Express ; 23(7): 8498-506, 2015 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-25968688

RESUMO

In this paper we present an anti-resonant guiding, low-loss Negative Curvature Fiber (NCF) for the efficient delivery of high energy short (ns) and ultrashort (ps) pulsed laser light in the green spectral region. The fabricated NCF has an attenuation of 0.15 dB/m and 0.18 dB/m at 532 nm and 515 nm respectively, and provided robust transmission of nanosecond and picosecond pulses with energies of 0.57 mJ (10.4 kW peak power) and 30 µJ (5 MW peak power) respectively. It provides single-mode, stable (low bend-sensitivity) output and maintains spectral and temporal properties of the source laser beam. The practical application of fiber-delivered pulses has been demonstrated in precision micro-machining and marking of metals and glass.

9.
Appl Opt ; 53(19): 4233-8, 2014 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-25089985

RESUMO

We report picosecond laser welding of similar and dissimilar materials based on plasma formation induced by a tightly focused beam from a 1030 nm, 10 ps, 400 kHz laser system. Specifically, we demonstrate the welding of fused silica, borosilicate, and sapphire to a range of materials including borosilicate, fused silica, silicon, copper, aluminum, and stainless steel. Dissimilar material welding of glass to aluminum and stainless steel has not been previously reported. Analysis of the borosilicate-to-borosilicate weld strength compares well to those obtained using similar welding systems based on femtosecond lasers. There is, however, a strong requirement to prepare surfaces to a high (10-60 nm Ra) flatness to ensure a successful weld.

10.
S Afr J Infect Dis ; 38(1): 481, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37293515

RESUMO

Background: Tuberculosis (TB) is treatable with a high cure rate. In South Africa, 70% of pulmonary TB is microbiologically confirmed. Autopsy studies of HIV-positive people found 45.7% undiagnosed TB cases. Objectives: The primary objective investigated whether CRP and a differentiated white cell count (WCC) and ratios thereof are useful screening tools for TB. Method: This retrospective cross-sectional study included adult patients admitted to two tertiary hospitals in Bloemfontein with TB workups between April 2016 and September 2019. National Health Laboratory Service (NHLS) provided laboratory data. Tuberculosis Xpert® MTB/RIF, Xpert® MTB/RIF Ultra and TB culture were used as reference standard for TB diagnosis. Results: The study population comprised 1294 patients; 15.1% had TB, 56.0% were male and 63.1% HIV-positive. Patients with TB were younger (p < 0.0001; 95% CI: -8;-3 years). In the total population, WCC had the highest area under the curve (0.59). White cell count (p < 0.0001), neutrophils (p = 0.0003) and lymphocytes (p = 0.0394) were lower in TB patients, and CRP-WCC ratio (CWR) (p = 0.0009) and CRP-lymphocyte ratio (CLR) (p = 0.0386) higher. In HIV-positive patients, WCC (p = 0.0003), neutrophils (p = 0.002) and lymphocytes (p = 0.0491) were lower in TB patients and CWR (p = 0.0043) higher. No parameter reached the World Health Organization screening targets of 70% specificity with 90% sensitivity. Conclusion: Differentiated WCC and CRP are not useful in screening hospitalised patients for TB in our setting. Contribution: Our study guides future research to augment current screening and diagnostic algorithms for TB, specifically in advanced HIV disease.

11.
Lab Chip ; 23(1): 62-71, 2022 12 20.
Artigo em Inglês | MEDLINE | ID: mdl-36477089

RESUMO

For many blood-based diagnostic tests, including prophylactic drug analysis and malaria assays, red blood cells must be lysed effectively prior to their use in an analytical workflow. We report on a finger-actuated blood lysate preparation device, which utilises a previously reported acoustofluidic micromixer module. The integrated device includes a range of innovations from a sample interface, to the integration of blisters on a laser engraved surface and a large volume (130 µL) one-stroke manual pump which could be useful in other low-cost microfluidic-based point-of-care devices. The adaptability of the acoustic mixer is demonstrated on highly viscous fluids, including whole blood, with up to 65% percent volume fraction of red blood cells. Used in conjunction with a lysis buffer, the micromixer unit is also shown to lyse a finger-prick (approximately 20 µL) blood sample in 30 seconds and benchmarked across ten donor samples. Finally, we demonstrate the ease of use of the fully integrated device. Cheap, modular, but reliable, finger-actuated microfluidic functions could open up opportunities for the development of diagnostics with minimal resources.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Dedos , Eritrócitos , Dispositivos Lab-On-A-Chip
12.
Micromachines (Basel) ; 9(8)2018 Aug 17.
Artigo em Inglês | MEDLINE | ID: mdl-30424342

RESUMO

Conventional manufacturing of microfluidic devices from glass substrates is a complex, multi-step process that involves different fabrication techniques and tools. Hence, it is time-consuming and expensive, in particular for the prototyping of microfluidic devices in low quantities. This article describes a laser-based process that enables the rapid manufacturing of enclosed micro-structures by laser micromachining and microwelding of two 1.1-mm-thick borosilicate glass plates. The fabrication process was carried out only with a picosecond laser (Trumpf TruMicro 5×50) that was used for: (a) the generation of microfluidic patterns on glass, (b) the drilling of inlet/outlet ports into the material, and (c) the bonding of two glass plates together in order to enclose the laser-generated microstructures. Using this manufacturing approach, a fully-functional microfluidic device can be fabricated in less than two hours. Initial fluid flow experiments proved that the laser-generated microstructures are completely sealed; thus, they show a potential use in many industrial and scientific areas. This includes geological and petroleum engineering research, where such microfluidic devices can be used to investigate single-phase and multi-phase flow of various fluids (such as brine, oil, and CO2) in porous media.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA