Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
Surg Endosc ; 37(11): 8421-8428, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37730850

RESUMO

INTRODUCTION: Inguinoscrotal hernias (ISH) pose a challenge to surgeons with consistently higher rates of postoperative complications and recurrence rates. The aim of this study is to report our initial experience and early results with a new technique for inguinoscrotal hernia repair. METHODS: A review of a prospectively maintained multi-center database was conducted in patients who underwent minimally invasive repair using the "primary abandon-of-the-sac" (PAS) technique for inguinoscrotal hernias from March 2021 to July 2022. Demographics and outcomes were analyzed. Univariate analysis and multivariate logistic regression were performed. RESULTS: A total of 76 minimally invasive inguinal hernia repairs were performed. In 70 patients (92%) C-PAS was used as the technique to abandon the sac while in the remaining 6 patients, "pirate-eye-patch" technique was used. Median hernia ring was 3 (IQR 2.5-3.5) cm and median hernia sac was 9.5 (8-10.8) cm. Median operative time was 70 min (IQR 56-96). Seroma was present in 22 (28.9%) patients 7 days after surgery. Most had seroma only in the inguinal area (n = 19; 25%). Thirty days after surgery, 12 (15.8%) patients still had seroma in the inguinal area and 6 (7.9%) in the inguinoscrotal area. Ninety days after surgery, four (5.3%) patients had inguinal seroma, 2 (2.6%) scrotal seromas and 3 (3.9%) inguinoscrotal seromas. The size of the hernia sac was not associated with seroma formation 7 days after surgery (OR 1.06; 95% CI 0.89-1.2; P = 0.461) in the multivariate logistic regression. BMI was also not associated with seroma formation (OR 0.8; 95% CI 0.74-1.06; P = 0.2). CONCLUSIONS: Planned abandon of the hernia sac is an interesting alternative and is associated with a low rate of complications and acceptable seroma formation rates.


Assuntos
Hérnia Inguinal , Laparoscopia , Masculino , Humanos , Seroma/epidemiologia , Seroma/etiologia , Laparoscopia/métodos , Telas Cirúrgicas/efeitos adversos , Hérnia Inguinal/cirurgia , Hérnia Inguinal/complicações , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Herniorrafia/métodos
2.
Langenbecks Arch Surg ; 408(1): 48, 2023 Jan 20.
Artigo em Inglês | MEDLINE | ID: mdl-36662265

RESUMO

PURPOSE: To compare the incidence of surgical site occurrences (SSOs) following onlay versus preperitoneal mesh placement in elective open umbilical hernia repairs. METHODS: This study presents a secondary analysis of a randomized double-blind trial conducted on female patients with primary umbilical hernias admitted to a general hospital, in a residency training program setting. Fifty-six subjects were randomly assigned to either onlay (n=30) or preperitoneal (n=26) mesh repair group. Data on baseline demographics, past medical history, perioperative details, postoperative pain (visual analogue scale (VAS)), wound-related complications, and recurrence were assessed using a standardized protocol. RESULTS: No statistically significant differences were observed between groups regarding patients' demographics, comorbidities, or defect size. Operative time averaged 67.5 (28-110) min for onlay and 50.5 (31-90) min for preperitoneal repairs, p=.03. The overall rate of SSOs was 21.4% (n=12), mainly in the onlay group (33% vs 7.7%; p=0.02, 95% CI 0.03-0.85) and mostly due to seromas. There were no between-group significant differences in postoperative VAS scores at all timepoints. After a maximum follow-up of 48 months, one recurrence was reported in the onlay group. By logistic regression, the onlay technique was the only independent risk factor for SSOs. CONCLUSION: The presented data identified a decreased wound morbidity in preperitoneal umbilical hernia repairs, thus contributing to the limited body of evidence regarding mesh place selection in future guidelines. Further cases from this ongoing study and completion of follow-up are expected to also compare both techniques in terms of long-term outcomes. TRIAL REGISTRATION NUMBER: Brazilian Registry of Clinical Trials (ReBEC) UTN code: U1111-1205-0065 (date of registration: March 27, 2018).


Assuntos
Hérnia Umbilical , Hérnia Ventral , Humanos , Feminino , Hérnia Umbilical/cirurgia , Telas Cirúrgicas/efeitos adversos , Estudos Prospectivos , Recidiva Local de Neoplasia/cirurgia , Procedimentos Cirúrgicos Eletivos/métodos , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Recidiva , Hérnia Ventral/cirurgia
3.
Surg Endosc ; 36(10): 7325-7333, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35676543

RESUMO

BACKGROUND: Robotic surgery is a valid option for minimally invasive surgery in most surgical specialties. However, the need to master laparoscopy is questionable before starting specific training in robotic surgery. We compared the development of basic robotic surgery skills between individuals randomized to train in conventional, laparoscopic, or robotic skills. METHODS: We conducted a single-centered, single-blinded randomized trial. Medical students were randomly assigned to 20 h of conventional, laparoscopic, or robotic surgical training. Students with previous surgical experience were excluded. Participants were evaluated pre- and post-training on the dV-Trainer robotic surgical simulator with the following exercises: Camera Targeting 1, Peg Board 1, Ring and Rail 1, and Ring and Rail 2. RESULTS: Sixty-six students were randomly assigned to each training group. Eight individuals did not complete the study (2 in the conventional group, 3 in the laparoscopic group, and 3 in the robotic group). All groups demonstrated significant improvement in the composite score and in each task following the training period (p < 0.001). No differences were seen between the conventional and laparoscopic groups in the composite score or individual tasks. The robotic group showed greater improvement in number of errors, economy of motion, workspace utilization, and time for completion compared to the other groups. The laparoscopic group showed improved camera manipulation skills compared to the conventional group, while the conventional group showed improved errors and economy of motion compared to the laparoscopic group. CONCLUSION: There was no difference in the acquisition of basic robotic surgical skills between individuals trained in basic conventional or laparoscopic surgical skills. We believe surgeons mastery in laparoscopy is not needed before initiating robotic surgical training. However, basic principles of laparoscopy remain applicable to robotic surgery. Future studies should compare transferability of conventional and laparoscopic training to robotic skills in the operating room.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Treinamento por Simulação , Competência Clínica , Simulação por Computador , Humanos , Laparoscopia/educação , Procedimentos Cirúrgicos Robóticos/educação , Robótica/educação
4.
Surg Endosc ; 35(10): 5414-5421, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34031740

RESUMO

BACKGROUND: A subcutaneous endoscopic onlay repair for ventral hernia with an anterior plication of diastasis recti (DR) has been published under different names in different countries. The aim of this systematic review is to assess the safety and feasibility of different named techniques with the same surgical concept. METHODS: The PRISMA guidelines were followed during all stages of this systematic review. The MINORS score system was used to perform qualitative assessment of all studies included in this review. Recommendations were then summarized for the following pre-defined key items: protocol, research question, search strategy, study eligibility, data extraction, study designs, risk of bias, publication bias, heterogeneity, and statistical analysis. RESULTS: The systematic literature search found 2548 articles, 317 of which were duplicates and excluded from analysis. The titles and abstracts from the remaining 2231 articles were assessed. After careful evaluation, 2125 articles were determined to be unrelated to our study and subsequently excluded. The full text of the remaining 106 articles was thoroughly assessed. Case reports, editorials, letters to the editor, and general reviews were then excluded. A total of 13 articles were ultimately included for this review, describing a similar subcutaneous endoscopic approach for repair of concomitant ventral hernias and rectus diastasis defined under nine different named techniques on 716 patients. The number of patients in those studies varied from 10 to 201. The mean operative time varied from 68.5 to 195 min. The most common complication was seroma, followed by pain requiring intervention, hematoma, and surgical site infection. CONCLUSIONS: There are a few technique variations described in different studies, but with no significant differences in outcomes. We, therefore, propose to unify these procedures under one term, ENDoscopic Onlay Repair (ENDOR). This technique has shown to be effective and safe, with seroma being the most common complication.


Assuntos
Diástase Muscular , Hérnia Ventral , Diástase Muscular/cirurgia , Endoscopia , Hérnia Ventral/cirurgia , Herniorrafia , Humanos , Reto do Abdome/cirurgia , Telas Cirúrgicas
5.
Surg Endosc ; 34(4): 1458-1464, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32076858

RESUMO

BACKGROUND: Although laparoscopic inguinal hernia repair was described about 30 years ago and advantages of the technique have been demonstrated, the utilization of this approach has not been what we would expect. Some reasons may be the need for surgeons to understand the posterior anatomy of the groin from a new vantage point, as well as to acquire advanced laparoscopic skills. Recently, however, the introduction of a robotic approach has dramatically increased the adoption of minimally invasive techniques for inguinal hernia repair. METHODS: Important recent contributions to this evolution have been the establishment of a new concept known as the critical view of the Myopectineal Orifice (MPO) and the description of a new way of understanding the posterior view of the antomy of the groin (inverted Y and the five triangles). In this paper, we describe 10 rules for a safe MIS inguinal hernia repair (TAPP, TEP, ETEP, RTAPP) that combines these two new concepts in a unique way. CONCLUSIONS: As the critical view of safety has made laparoscopic cholecystectomy safer, we feel that following our ten rules based on understanding the anatomy of the posterior groin as defined by zones and essential triangles and the technical steps to achieve the critical view of the MPO will foster the goal of safe MIS hernia repair, no matter which minimally invasive technique is employed.


Assuntos
Colecistectomia Laparoscópica/normas , Virilha/cirurgia , Hérnia Inguinal/cirurgia , Herniorrafia/normas , Cirurgia Endoscópica por Orifício Natural/normas , Colecistectomia Laparoscópica/métodos , Herniorrafia/métodos , Humanos , Cirurgia Endoscópica por Orifício Natural/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/normas
6.
World J Urol ; 36(4): 595-601, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29459996

RESUMO

INTRODUCTION: There is no information about the evolution of robotic programs in public hospitals of Latin-America. OBJECTIVE: To describe the current status and functioning of robotic programs in Latin-American public hospitals since their beginning to date. METHODS: We conducted a survey among leading urologists working at public hospitals of Latin-America who had acquired the Da Vinci laparoscopic-assisted robotic system. Questions included: date the program started, its utilization by other services, number and kind of surgeries, surgery paying system, surgery related deaths, occurrence and reasons of robotic program interruptions and its use for training purposes. Medians and 25-75 centiles (IQR) were estimated. RESULTS: Since 2009, there are ten public hospitals of four Latin-American countries that acquired the Da Vinci robotic system. The median number of months robotic programs has been functioning without considering transitory interruption: 43 (IQR 35, 55). Median number of urologic and total surgeries performed: 140 (IQR 94, 168) and 336 (IQR 292, 621), respectively. The corresponding median number of urologic and total surgeries performed per month: 3 (IQR 2, 5) and 8 (IQR 5, 11). Median number of total surgeries performed per year per institution was 94 (IQR 68,123). The median proportion of urologic cases was 40% (IQR 31, 48), ranging from 24 to 66%. Five of ten institutions had their urology programs transitory or definitively closed due to the high burden costs. CONCLUSION: Adoption and development of robotic surgery in some public hospitals of Latin-America have been hindered by high costs.


Assuntos
Hospitais Públicos/estatística & dados numéricos , Procedimentos Cirúrgicos Robóticos , Procedimentos Cirúrgicos Urológicos , Custos e Análise de Custo , Pesquisas sobre Atenção à Saúde , Humanos , América Latina , Avaliação das Necessidades , Procedimentos Cirúrgicos Robóticos/economia , Procedimentos Cirúrgicos Robóticos/estatística & dados numéricos , Procedimentos Cirúrgicos Urológicos/métodos , Procedimentos Cirúrgicos Urológicos/estatística & dados numéricos
7.
Surg Endosc ; 32(11): 4688-4697, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-30022288

RESUMO

BACKGROUND: In order to simplify a percutaneous gastrostomy procedure and avoid the need of endoscopy or imaging methods, a novel percutaneous magnetically guided gastrostomy (PMG) technique was conceived. The aim of the present study is to evaluate the feasibility of a novel PMG technique with no endoscopy or any imaging guidance in a porcine model. METHODS: Fourteen crossbred domestic pigs were used for prototype development (cadaveric experiments) and proof-of concept, survival study. The magnetic device was conceived using commercially available rare-earth neodymium-based magnets. The experimental design consisted of developing an internal magnetic gastric tube prototype to be orally inserted and coupled to an external magnet placed on the skin, which facilitated stomach and abdominal wall apposition for blind percutaneous gastrostomy tube placement. Then, a gastrostomy tube was percutaneously and blindly placed. RESULTS: Twelve procedures were undertaken in animal cadavers and two in live models. The technique chosen consisted of using a magnetic gastric tube prototype using six 1 × 1-cm-ring magnets attached to its end. This device enabled successful magnetic coupling with a large (5 cm in diameter) magnet disc placed on the skin. For gastric tube placement, a direct trocar insertion allowed easier and safer placement of a gastric tube as compared to a needle-guide-wire dilation (Seldinger-based) technique. Gastropexy was added to avoid early gastric tube displacement. This novel PMG technique was feasible in a live model experiment. CONCLUSIONS: A novel magnetically guided percutaneous gastrostomy tube insertion technique without the use of endoscopy or image-guidance was successful in a porcine model. A non-inferiority experimental controlled study comparing this technique to percutaneous endoscopic gastrostomy is needed to confirm its efficacy and safety.


Assuntos
Gastropexia/métodos , Gastrostomia , Complicações Intraoperatórias/prevenção & controle , Intubação Gastrointestinal , Imãs , Estômago/cirurgia , Animais , Estudos de Viabilidade , Gastrostomia/efeitos adversos , Gastrostomia/métodos , Cuidados Intraoperatórios/métodos , Intubação Gastrointestinal/efeitos adversos , Intubação Gastrointestinal/métodos , Modelos Anatômicos , Suínos
8.
Int Braz J Urol ; 43(6): 1176-1184, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28727367

RESUMO

PURPOSE: Robotic assisted radical prostatectomy (RARP) presents challenges for the surgeon, especially during the initial learning curve. We aimed to evaluate early and mid-term functional outcomes and complications related to vesicourethral anastomosis (VUA), in patients who underwent RARP, during the initial experience in an academic hospital. We also assessed possible predictors of postoperative incontinence and compared these results with the literature. MATERIALS AND METHODS: We prospectively collected data from consecutive patients that underwent RARP. Patients with at least 6 months of follow-up were included in the analysis for the following outcomes: time to complete VUA, continence and complications related to anastomosis. Nerve-sparing status, age, BMI, EBL, pathological tumor staging, and prostate size were evaluated as possible factors predicting early and midterm continence. Results were compared with current literature. RESULTS: Data from 60 patients was assessed. Mean time to complete VUA was 34 minutes, and console time was 247 minutes. Continence in 6 months was 90%. Incidence of urinary leakage was 3.3%, no patients developed bladder neck contracture or postoperative urinary retention. On multivariate analysis, age and pathological staging was associated to 3-month continence status. CONCLUSION: Our data show that, during early experience with RARP in a public university hospital, it is possible to achieve good results regarding continence and other outcomes related to VUA. We also found that age and pathological staging was associated to early continence status.


Assuntos
Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Procedimentos Cirúrgicos Robóticos/métodos , Uretra/cirurgia , Bexiga Urinária/cirurgia , Idoso , Anastomose Cirúrgica/efeitos adversos , Anastomose Cirúrgica/métodos , Hospitais Universitários , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Prostatectomia/efeitos adversos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Resultado do Tratamento
10.
J Minim Access Surg ; 12(2): 129-34, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27073304

RESUMO

CONTEXT: With the cooperation of surgeons and the engineering division of the company Bhio supply(©) (Esteio-RS, Brazil), a permanent single port was developed. AIMS: An experimental study assessed the safety and efficacy of the device using a swine laparoscopic appendectomy model (right salpingo-oophorectomy). SETTINGS AND DESIGN: Experimental randomised study. MATERIALS AND METHODS: A total of 20 pigs were randomised for the conventional laparoscopic (CL) three-trocar technique or the single Centry port (CPort) with two working channels, aided by a transparietal thread. Operative times, surgical complications, CO2 use, and pneumoperitoneal pressure were checked. Pressure and chromopertubation tests assessed the ligatures. STATISTICAL ANALYSIS USED: For quantitative outcomes, the Fisher's exact test analysed the samples to compare the surgeons in each group, the ANOVA test for parametric data (volume and pressure) and the Student's t-test for analysis of the fascial incision length. The binaries and isolated occurrence events were described in percentages. RESULTS: For all cases, pneumoperitoneum was maintained. The CPort group, however, resulted in higher CO2 use (26.18 l; standard deviation [SD] ± 11.09) than CL group (5.69 l; SD ± 2.44) (P < 0.01). The mean pressure in CPort group (6.604 mmHg, SD ± 1.793) was comparatively lower than in CL group (7.382 mmHg, SD ± 1.833) (P = 0.363). There was no statistical difference between operative times, ligature safety or adverse surgical events between the different groups and surgeons. CONCLUSION: The surgical technique used with the single port showed no differences in safety and efficacy. Though it does require more CO2 use, its working dynamics did not lead to increased operative times. The results were similar between the two surgeons in the study, suggesting that they can be reproduced.

11.
World J Surg ; 38(8): 1912-6, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-24615611

RESUMO

BACKGROUND: Over the last two decades, video-assisted surgery has become the preferential access route for many procedures. Despite cholecystectomy being the laparoscopic procedure most frequently performed in Brazilian public hospitals from 2008 to 2012, the lack of population-based studies led us to conduct a survey on the prevalence of video-assisted surgery in the treatment of patients using the Sistema Único de Saúde (SUS) (Unified Health System), which is the universal, free, and public healthcare system of Brazil. METHODS: By analyzing the DATASUS (national public health registry database), the prevalence of laparoscopic cholecystectomy and open cholecystectomy (OC) was calculated in the period from January to December in 2008, 2010 and 2012, taking into consideration their geographic distribution throughout Brazil. RESULTS: At the end of the study period, an increase in the number of laparoscopic cholecystectomies was observed, with a variation of 125.7%. However, OC was more prevalent despite an increase in the use of video-assisted surgery over the 5-year study period, increasing from 12 to 25% in 2012. CONCLUSIONS: In spite of a trend toward increased use of video-assisted surgery for treating SUS patients during the period under study, the data from 2012 are still far from being ideal. For this population, OC via laparotomy is still the most prevalent option in all regions. This information must encourage the Brazilian surgical societies to push for an improvement in the supply of the treatment provided by the public health system.


Assuntos
Colecistectomia Laparoscópica/estatística & dados numéricos , Países em Desenvolvimento , Programas Nacionais de Saúde , Cirurgia Vídeoassistida/estatística & dados numéricos , Brasil , Colecistectomia Laparoscópica/tendências , Estudos Transversais , Pesquisas sobre Atenção à Saúde , Hospitais Públicos , Humanos , Sistema de Registros , Cirurgia Vídeoassistida/tendências
12.
J Minim Access Surg ; 10(1): 23-6, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24501505

RESUMO

BACKGROUND: According to the precepts of reduced surgical trauma and better cosmesis, an intermediate laparoscopic appendectomy technique between the conventional three-trocar procedure and Laparoendoscopic Single Site Surgery (LESS) was performed, based on literature review and experience of the surgical team. PATIENTS AND METHODS: Patients with early stage acute appendicitis and a favourable anatomical presentation were selected. The procedure was performed with two ports: A 10 mm trocar at the umbilicus site for laparoscope and a 5 mm one just above the pubic bone for grasper. The appendix was secured by external wire traction through a right iliac fossa puncture with 14-gauge intravenous catheter. RESULTS: From August 2009 to December 2012, we performed 42 cases; two required conversion to a conventional laparoscopic technique. There were no complications in the remaining, no wound infections and a mean operation time of 64.5 minutes. CONCLUSION: The use of two-port laparoscopic appendectomy can act as a LESS intermediate step procedure, without loss of instrumental triangulation and maintenance of appropriate counter-traction. This technique can be used as an alternative to the three-port laparoscopic procedure in patients with initial presentation of appendicitis and a favourable anatomical position.

13.
J Laparoendosc Adv Surg Tech A ; 34(2): 144-146, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38054942

RESUMO

Background: The aim of our technical report is to demonstrate the image inversion technique in the new Versius Robotic System. Methods: We report a step-by-step surgical maneuver for robotic surgeons when performing robotic ventral hernia repair (VHR) with the Versius Robotic System. Technical Report: The image inversion artifice consists in rotating 180° with the scope using the surgeon's master control in a specific rotation command in the right-hand joystick. The assisting surgeon can do a manual inversion of the camera without the console being aware that the scope is inverted. In this scenario, the 30° Up configuration should be used while informing the console that the scope is looking down. The surgeon can reassign instruments to each joystick. This results in the right joystick controlling the left instrument and left control controlling the right instrument. Since the image is inverted, the movements will look natural on the surgeon console. Conclusions: The use of the image inversion technique with the Versius Robotic System is effective in aiding surgeons to perform the hernia defect closure during robotic VHRs.


Assuntos
Hérnia Ventral , Procedimentos Cirúrgicos Robóticos , Robótica , Cirurgiões , Humanos , Estudos de Viabilidade , Hérnia Ventral/cirurgia , Herniorrafia/métodos , Procedimentos Cirúrgicos Robóticos/métodos
14.
Hernia ; 2024 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-38852123

RESUMO

INTRODUCTION: Ventral hernia surgery (VHS) has the intent to promote a better quality of life (QoL). VHS results were evaluated by recurrence incidence in the past, however the concept of Patient-Reported Outcomes Measures has changed this scenario. SF-36 is a generic questionnaire with some limitations on the hernioplasty postoperative evaluation. Disease-specific surveys such Hernia-Related Quality of Life Survey (HerQLes) and Carolinas Comfort Scale (CCS) were developed to improve specificity. The aim of this study was to validate a Brazilian version of the CCS as a QoL questionnaire for patients undergoing VHS in Brazil. MATERIALS AND METHODS: The study consists of a retrospective cohort that reviewed the medical records of patients who underwent ventral hernia surgery for incisional hernias in the Hospital de Clínicas de Porto Alegre between January 2019 to December 2020. Participants answered both the HerQles questionnaire and the CCS, then we compared the patients' scores between scales. In-personal evaluations or surveys applied by telemedicine were performed. Intraclass correlation coefficient was utilized to assess the consistency of the agreement between the HerQLes and CCS scales. RESULTS: A sample of 80 patients were evaluated. Most were male (70%), mean age 61.11 years and BMI 28.4. The most common comorbidity was systemic arterial hypertension, one third were smokers and 77.5% of cases were ASA 2. The average HerQLes score was 30.40 and the CCS was 15.46 (SD: 21.81), with an intraclass coefficient of 0.68. CONCLUSION: This study suggests that CCS is a good and robust tool for assessing ventral hernia. Tools to measure QoL are increasingly used in the literature, as QoL seems to be important data to assess surgical success, since it shows the perception of the patient about the results of their surgery. Further studies with larger sample sizes should be performed to confirm our findings.

15.
J Laparoendosc Adv Surg Tech A ; 34(4): 365-367, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38354285

RESUMO

ChatGPT is a conversational AI model developed by OpenAI to generate human-like text based on the input it receives. ChatGPT has become increasingly popular, and the general public may use this tool to ask questions about different medical conditions. There is a lack of data to demonstrate ChatGPT is able to provide reliable information on medical conditions. The aim of our study is to assess the accuracy and appropriateness of ChatGPT answers to questions on ventral hernia management.


Assuntos
Inteligência Artificial , Hérnia Ventral , Humanos , Hérnia Ventral/cirurgia , Herniorrafia , Comunicação
16.
J Laparoendosc Adv Surg Tech A ; 34(2): 141-143, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38126878

RESUMO

ChatGPT is a conversational AI model developed by OpenAI designed to generate human-like text based on the input it receives. ChatGPT has become increasingly popular, and the general public may use this tool to ask questions about different medical conditions. There is a lack of data showing if ChatGPT is able to provide reliable information on medical conditions to the general public. The aim of our study is to assess the accuracy and appropriateness of ChatGPT answers to questions on inguinal hernia management.


Assuntos
Hérnia Inguinal , Humanos , Hérnia Inguinal/cirurgia , Inteligência Artificial , Comunicação
17.
Surgery ; 175(4): 1071-1080, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38218685

RESUMO

BACKGROUND: Different unilateral groin hernia repair approaches have been developed in the last 2 decades. The most commonly done approaches are open inguinal hernia repair by the Lichenstein technique, laparoscopic approach by either total extraperitoneal or transabdominal preperitoneal, and robotic transabdominal preperitoneal approach. Hence, this study aimed to compare early and late postoperative outcomes in patients who underwent unilateral robotic transabdominal preperitoneal, laparoscopic transabdominal preperitoneal, and laparoscopic total extraperitoneal, and open groin hernia repair using a United States national hernia database, the Abdominal Core Health Quality Collaborative Database. METHODS: Prospectively collected data from the Abdominal Core Health Quality Collaborative database was retrospectively reviewed, including all adult patients who underwent elective unilateral groin hernia repair from 2015 to 2022, with a 1:1 propensity score match analysis conducted for balanced groups. The univariate analysis compared the groups across the preoperative, intraoperative, and postoperative timeframes. RESULTS: The Abdominal Core Health Quality Collaborative database identified 14,320 patients who underwent elective unilateral groin hernia repair and had documented 30 days of follow-up. Propensity score matching stratified 1,598 patients to each group (total of 6,392). The median age was 64 years (interquartile range 53-74) for open groin hernia repair, whereas 60 (interquartile range 47-69) for laparoscopic transabdominal preperitoneal, 62 (interquartile range 48-70) for laparoscopic total extraperitoneal, and 60 (interquartile range 47-70) for robotic transabdominal preperitoneal were noted. Open groin hernia repair had more American Society of Anesthesiologists score 4 (52, 3%) patients (P < .001). A painful bulge was the most common indication (>85%). Operating room time >2 hours was more significant in the robotic transabdominal preperitoneal group (123, 8%; P < .001). Seroma rate was higher in the laparoscopic transabdominal preperitoneal (134, 8%; P < .001). A 1-year analysis had 1,103 patients. Hematoma, surgical site infection, readmission, reoperation, and hernia recurrence at 30 days or 1 year did not differ, with an overall recurrence rate of 6% (n = 67) at 1 year (P = .33). In patients with body mass index ≥30 kg/m2, the robotic approach had lower rates of surgical site occurrence (n = 12, 4%; P = .002) and seroma (n = 5, 2%; P < .001) compared with the other groups. When evaluating recurrence 1 year after surgery, the robotic transabdominal preperitoneal group had 10% versus 18% open groin hernia repair, 11% laparoscopic transabdominal preperitoneal, and 18% laparoscopic total extraperitoneal, but it was not statistically significant (P = .53). CONCLUSION: There was no difference in readmission, reoperation, and surgical site infection among the surgical techniques at 30 days. However, laparoscopic transabdominal preperitoneal was associated with more seromas. Hernia recurrence at 1 year was similar across groups; the robotic approach had the lowest recurrence rate among all 3 repairs but did not reach statistical significance. The robotic approach performed better in patients with a body mass index of 30 kg/m2 for surgical site occurrence and seroma than in other surgical techniques.


Assuntos
Hérnia Inguinal , Laparoscopia , Adulto , Humanos , Pessoa de Meia-Idade , Infecção da Ferida Cirúrgica/cirurgia , Herniorrafia/efeitos adversos , Herniorrafia/métodos , Virilha/cirurgia , Estudos Retrospectivos , Seroma , Pontuação de Propensão , Resultado do Tratamento , Telas Cirúrgicas , Hérnia Inguinal/cirurgia , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Dor Pós-Operatória/epidemiologia , Centro Abdominal
18.
Surg Endosc ; 27(2): 421-7, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22806514

RESUMO

INTRODUCTION: Bacterial contamination from viscerotomy is a barrier to natural orifice translumenal endoscopic surgery (NOTES). The aim of this survival study is to evaluate pure (totally) transvaginal NOTES bacterial contamination compared with laparoscopy in pigs. METHODS: Twelve adult female pigs underwent peritoneoscopy with liver and peritoneal biopsies, using either laparoscopy (Glap, six animals) or pure transvaginal (GNOTES) access, and were maintained alive for 7 days. In all animals, blood cultures were taken at baseline, and after 24 h and 7 days postoperatively. Swab cultures from vagina (GNOTES) and skin (Glap) were obtained pre- and post-antisepsis. Peritoneal fluid culture was obtained at necropsy. For statistical analysis, Glap and GNOTES were compared for presence of positive bacterial cultures (qualitative bacterial analysis) using Fisher's test, with level of significance set at p < 0.05. RESULTS: All animals had good postoperative outcome. One animal had transient perioperative bleeding from a transvaginal access. Two animals in Glap and one in GNOTES had positive blood cultures after the procedure. All animals from GNOTES and Glap presented with mixed flora pre-antisepsis. After antisepsis, one animal (GNOTES) presented with a positive vaginal swab culture (a single bacterial strain was identified). There was no positive skin swab culture in Glap. There were no signs of intra-abdominal infection at necropsy. In two animals, one from Glap and another from GNOTES, intra-abdominal culture was positive for Corynebacterium spp. and Escherichia coli, respectively. There was no correlation between the bacterial flora found at the access site and in the peritoneal cultures. CONCLUSIONS: Pure transvaginal peritoneoscopy with liver and peritoneal biopsy in swine is feasible and associated with bacterial contamination comparable to laparoscopy. Peritoneal bacterial contamination was clinically insignificant after 1 week postoperatively. Preoperative antisepsis provided significant reduction of bacterial load prior to transvaginal and laparoscopic procedures.


Assuntos
Bactérias/isolamento & purificação , Laparoscopia , Cirurgia Endoscópica por Orifício Natural , Pele/microbiologia , Vagina/microbiologia , Animais , Biópsia , Feminino , Fígado/patologia , Cirurgia Endoscópica por Orifício Natural/métodos , Peritônio/patologia , Suínos
19.
Arq Bras Cir Dig ; 36: e1777, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38088723

RESUMO

BACKGROUND: Adhesive small bowel obstruction is one of the most common causes of surgical emergencies, representing about 15% of hospital admissions. Defining the need and timing of surgical intervention still remains a challenge. AIMS: To report the experience of using meglumine-based water-soluble contrast in a tertiary hospital in southern Brazil, comparing with the world literature. METHODS: Patients suspected of having adhesive small bowel obstruction, according to their clinical conditions, underwent an established protocol, consisting of the administration of water-soluble contrast, followed by plain abdominal radiograph within 12 hours and by a new clinical evaluation. The protocol was initiated after starting conservative management, including fasting and placement of a nasogastric tube, as well as intravenous fluid reposition. RESULTS: A total of 126 patients were submitted to the protocol. The water-soluble contrast test sensitivity and specificity after the first radiograph were 94.6 and 91.0%, respectively; after the second radiograph, these values were 92.3 and 100%. The general test values for sensitivity and specificity were 91.9 and 100%, respectively. CONCLUSIONS: The measure parameters evaluated in this study were similar to those found in the literature, contributing to endorse the importance of this test in the evaluation of patients with adhesive small bowel obstruction. The particular relevance of this study was the similar results that were found using a different type of meglumine-based contrast, which is available in Brazil.


Assuntos
Diatrizoato de Meglumina , Obstrução Intestinal , Humanos , Diatrizoato de Meglumina/uso terapêutico , Aderências Teciduais/diagnóstico por imagem , Meios de Contraste/uso terapêutico , Obstrução Intestinal/diagnóstico por imagem , Obstrução Intestinal/cirurgia , Meglumina/uso terapêutico , Água
20.
J Abdom Wall Surg ; 2: 11246, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38312429

RESUMO

Introduction: The number of surgeries for groin hernia (GH) among the elderly follows the increase in life expectancy of the population. The greater number and severity of comorbidities in this group increases the surgical risk, promoting discussion regarding the indication of elective surgery and the benefits of watchful waiting approach (WWA). The aim of the present study was to evaluate the outcomes of emergency hernia surgery among the elderly population. Materials and methods: A systematic review was performed in Pubmed and Scielo databases for the past early 10 years, until July 2022. The subject was groin hernia in the emergency setting focusing the elderly population. The PRISMA statement was followed and the classification of elderly was based on the World Health Organization's definition. Results: A total of 1,037 results were returned and we ended with nine original articles with emphasis in groin hernia in the emergency among the elderly population. In these subjects, the complications rate ranged between 21.2% and 28.9% and the mortality rate ranged between 1.2% and 6%. Cardiopulmonary disease, high ASA and Charlson's scales were associated with greater risk of complications and death. Conclusion: Emergency GH surgery in the elderly population carries an increased risk of complications and mortality. GH surgery is safe or, at least, less harmful when done electively. The risk and benefits of WWA and upfront surgery needs to be assessed and exposed to the patients. Our review sugest that elective surgery should be the option over WWA in this patient population.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA