Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38960805

RESUMO

OBJECTIVE: To evaluate the impact of inflammation on anticoagulation monitoring for patients supported with extracorporeal membrane oxygenation (ECMO). DESIGN: Prospective single-center cohort study. SETTING: University-affiliated tertiary care academic medical center. PARTICIPANTS: Adult venovenous and venoarterial ECMO patients anticoagulated with heparin/ MEASUREMENTS AND MAIN RESULTS: C-Reactive protein (CRP) was used as a surrogate for overall inflammation. The relationship between CRP and the partial thromboplastin time (PTT, seconds) was evaluated using a CRP-insensitive PTT assay (PTT-CRP) in addition to measurement using a routine PTT assay. Data from 30 patients anticoagulated with heparin over 371 ECMO days was included. CRP levels (mg/dL) were significantly elevated (median, 17.2; interquartile range [IQR], 9.2-26.1) and 93% of patients had a CRP of ≥5. The median PTT (median 58.9; IQR, 46.9-73.3) was prolonged by 11.3 seconds compared with simultaneously measured PTT-CRP (median, 47.6; IQR, 40.1-55.5; p < 0.001). The difference between PTT and PTT-CRP generally increased with CRP elevation from 2.7 for a CRP of <5.0 to 13.0 for a CRP between 5 and 10, 17.7 for a CRP between 10 and 15, and 15.1 for a CRP of >15 (p < 0.001). In a subgroup of patients, heparin was transitioned to argatroban, and a similar effect was observed (median PTT, 62.1 seconds [IQR, 53.0-78.5 seconds] vs median PTT-CRP, 47.6 seconds [IQR, 41.3-57.7 seconds]; p < 0.001). CONCLUSIONS: Elevations in CRP are common during ECMO and can falsely prolong PTT measured by commonly used assays. The discrepancy due to CRP-interference is important clinically given narrow PTT targets and may contribute to hematological complications.

2.
Nat Biomed Eng ; 3(8): 611-620, 2019 08.
Artigo em Inglês | MEDLINE | ID: mdl-31391596

RESUMO

Post-operative adhesions form as a result of normal wound healing processes following any type of surgery. In cardiac surgery, pericardial adhesions are particularly problematic during reoperations, as surgeons must release the adhesions from the surface of the heart before the intended procedure can begin, thereby substantially lengthening operation times and introducing risks of haemorrhage and injury to the heart and lungs during sternal re-entry and cardiac dissection. Here we show that a dynamically crosslinked supramolecular polymer-nanoparticle hydrogel, with viscoelastic and flow properties that enable spraying onto tissue as well as robust tissue adherence and local retention in vivo for two weeks, reduces the formation of pericardial adhesions. In a rat model of severe pericardial adhesions, the hydrogel markedly reduced the severity of the adhesions, whereas commercial adhesion barriers (including Seprafilm and Interceed) did not. The hydrogels also reduced the severity of cardiac adhesions (relative to untreated animals) in a clinically relevant cardiopulmonary-bypass model in sheep. This viscoelastic supramolecular polymeric hydrogel represents a promising clinical solution for the prevention of post-operative pericardial adhesions.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Hidrogéis/química , Pericárdio/cirurgia , Polímeros/química , Aderências Teciduais , Animais , Celulose Oxidada , Ácido Hialurônico , Hidrogéis/uso terapêutico , Masculino , Modelos Animais , Nanopartículas , Polímeros/uso terapêutico , Ratos , Ovinos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA