Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Med Phys ; 39(8): 4886-95, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22894415

RESUMO

PURPOSE: To compare the breast volume (BV), fibroglandular tissue volume (FV), and percent density (PD) measured from breast MRI of the same women using four different MR scanners. METHODS: The study was performed in 34 healthy Asian volunteers using two 1.5T (GE and Siemens) and two 3T (GE and Philips) MR scanners. The BV, FV, and PD were measured on nonfat-suppressed T1-weighted images using a comprehensive computer algorithm-based segmentation method. The scanner-to-scanner measurement difference, and the coefficient of variation (CV) among the four scanners were calculated. The measurement variation between two density morphological patterns presenting as the central type and the intermingled type was separately analyzed and compared. RESULTS: All four scanners provided satisfactory image quality allowing for successful completion of the segmentation processes. The measured parameters between each pair of MR scanners were highly correlated, with R(2) ≥ 0.95 for BV, R(2) ≥ 0.99 for FV, and R(2) ≥ 0.97 for PD in all comparisons. The mean percent differences between each pair of scanners were 5.9%-7.8% for BV, 5.3%-6.5% for FV, 4.3%-7.3% for PD; with the overall CV of 5.8% for BV, 4.8% for FV, and 4.9% for PD. The variation of FV was smaller in the central type than in the intermingled type (p = 0.04). CONCLUSIONS: The results showed that the variation of FV and PD measured from four different MR scanners is around 5%, suggesting the parameters measured using different scanners can be used for a combined analysis in a multicenter study.


Assuntos
Mama/patologia , Imageamento por Ressonância Magnética/métodos , Tecido Adiposo/patologia , Adulto , Algoritmos , Povo Asiático , Desenho de Equipamento , Feminino , Humanos , Processamento de Imagem Assistida por Computador/métodos , Pessoa de Meia-Idade , Modelos Estatísticos , Reprodutibilidade dos Testes
2.
Med Phys ; 38(11): 5961-8, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-22047360

RESUMO

PURPOSE: To investigate the difference of MR percent breast density measured from fat-suppressed versus nonfat-suppressed imaging sequences. METHODS: Breast magnetic resonance imaging (MRI) with and without fat suppression was acquired from 38 subjects. Breasts were divided into subgroups of different morphological patterns ("central" and "intermingled" types). Breast volume, fibroglandular tissue volume, and percent density were measured. The results were compared using nonparametric statistical tests and regarded as significant at p < 0.05. RESULTS: Breast volume, fibroglandular volume, and percent density between fat-suppressed and nonfat-suppressed sequences were highly correlated. Breast volumes measured on these two sequences were almost identical. Fibroglandular tissue volume and percent density, however, had small (<5%) yet significant differences between the two sequences-they were both higher on the fat-suppressed sequence. Intraobserver variability was within 4% for both sequences and different morphological types. The fibroglandular tissue volume measured on downsampled images showed a small (<5%) yet significant difference. CONCLUSIONS: The measurement of breast density made on MRI acquired using fat-suppressed and nonfat-suppressed T1W images was about 5% difference, only slightly higher than the intraobserver variability of 3%-4%. When the density data from multiple centers were to be combined, evaluating the degree of difference is needed to take this difference into account.


Assuntos
Tecido Adiposo/citologia , Mama/citologia , Processamento de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Pessoa de Meia-Idade , Variações Dependentes do Observador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA