Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Opt Lett ; 45(24): 6595-6598, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-33325848

RESUMO

Over the past two decades, integrated photonic sensors have been of major interest to the optical biosensor community due to their capability to detect low concentrations of molecules with label-free operation. Among these, interferometric sensors can be read-out with simple, fixed-wavelength laser sources and offer excellent detection limits but can suffer from sensitivity fading when not tuned to their quadrature point. Recently, coherently detected sensors were demonstrated as an attractive alternative to overcome this limitation. Here we show, for the first time, to the best of our knowledge, that this coherent scheme provides sub-nanogram per milliliter limits of detection in C-reactive protein immunoassays and that quasi-balanced optical arm lengths enable operation with inexpensive Fabry-Perot-type lasers sources at telecom wavelengths.


Assuntos
Técnicas Biossensoriais/instrumentação , Proteína C-Reativa/análise , Imunoensaio/instrumentação , Interferometria/instrumentação , Silício/química , Óptica e Fotônica , Processos Fotoquímicos
2.
Sensors (Basel) ; 20(11)2020 Jun 02.
Artigo em Inglês | MEDLINE | ID: mdl-32498466

RESUMO

Ring resonator-based biosensors have found widespread application as the transducing principle in "lab-on-a-chip" platforms due to their sensitivity, small size and support for multiplexed sensing. Their sensitivity is, however, not inherently selective towards biomarkers, and surface functionalization of the sensors is key in transforming the sensitivity to be specific for a particular biomarker. There is currently no consensus on process parameters for optimized functionalization of these sensors. Moreover, the procedures are typically optimized on flat silicon oxide substrates as test systems prior to applying the procedure to the actual sensor. Here we present what is, to our knowledge, the first comparison of optimization of silanization on flat silicon oxide substrates to results of protein capture on sensors where all parameters of two conjugation protocols are tested on both platforms. The conjugation protocols differed in the chosen silanization solvents and protein immobilization strategy. The data show that selection of acetic acid as the solvent in the silanization step generally yields a higher protein binding capacity for C-reactive protein (CRP) onto anti-CRP functionalized ring resonator sensors than using ethanol as the solvent. Furthermore, using the BS3 linker resulted in more consistent protein binding capacity across the silanization parameters tested. Overall, the data indicate that selection of parameters in the silanization and immobilization protocols harbor potential for improved biosensor binding capacity and should therefore be included as an essential part of the biosensor development process.


Assuntos
Anticorpos Imobilizados , Técnicas Biossensoriais , Óptica e Fotônica , Biomarcadores , Proteína C-Reativa/análise , Fótons
3.
J Perinatol ; 43(6): 758-765, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36539561

RESUMO

OBJECTIVES: Determine if chronologic age and/or chorioamnionitis exposure alter normal serum cytokine and chemokine levels in uninfected preterm neonates during their initial NICU stay. STUDY DESIGN: A 7-plex immunoassay measured levels of serum IL-1ß, IL-6, IL-8, IL-10, TNF-α, CCL2, and CCL3 longitudinally from chorioamnionitis-exposed and unexposed preterm neonates under 33 weeks' gestation. RESULTS: Chorioamnionitis-exposed and unexposed preterm neonates demonstrated differences in the trends of IL-1ß, IL-6, IL-8, IL-10, TNF-α, and CCL2 over the first month of life. The unexposed neonates demonstrated elevated levels of these inflammatory markers in the first two weeks of life with a decrease by the third week of life, while the chorioamnionitis-exposed neonates demonstrated differences over time without a predictable pattern. Chorioamnionitis-exposed and unexposed neonates demonstrated altered IL-10 and TNF-α trajectories over the first twelve weeks of life. CONCLUSION: Chorioamnionitis induces a state of immune dysregulation in preterm neonates that persists beyond the immediate neonatal period.


Assuntos
Corioamnionite , Citocinas , Recém-Nascido , Gravidez , Feminino , Humanos , Interleucina-10 , Interleucina-6 , Fator de Necrose Tumoral alfa , Interleucina-8
4.
Sci Rep ; 11(1): 20544, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34654869

RESUMO

Accurate detection and risk stratification of latent tuberculosis infection (LTBI) remains a major clinical and public health problem. We hypothesize that multiparameter strategies that probe immune responses to Mycobacterium tuberculosis can provide new diagnostic insights into not only the status of LTBI infection, but also the risk of reactivation. After the initial proof-of-concept study, we developed a 13-plex immunoassay panel to profile cytokine release from peripheral blood mononuclear cells stimulated separately with Mtb-relevant and non-specific antigens to identify putative biomarker signatures. We sequentially enrolled 65 subjects with various risk of TB exposure, including 32 subjects with diagnosis of LTBI. Random Forest feature selection and statistical data reduction methods were applied to determine cytokine levels across different normalized stimulation conditions. Receiver Operator Characteristic (ROC) analysis for full and reduced feature sets revealed differences in biomarkers signatures for LTBI status and reactivation risk designations. The reduced set for increased risk included IP-10, IL-2, IFN-γ, TNF-α, IL-15, IL-17, CCL3, and CCL8 under varying normalized stimulation conditions. ROC curves determined predictive accuracies of > 80% for both LTBI diagnosis and increased risk designations. Our study findings suggest that a multiparameter diagnostic approach to detect normalized cytokine biomarker signatures might improve risk stratification in LTBI.


Assuntos
Técnicas Biossensoriais , Citocinas/metabolismo , Tuberculose Latente/metabolismo , Leucócitos Mononucleares/metabolismo , Aprendizado de Máquina , Adulto , Idoso , Células Cultivadas , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA