RESUMO
BACKGROUND: Circulating cell free DNA (cfDNA) testing of plasma for EGFR somatic variants in lung cancer patients is being widely implemented and with any new service, external quality assessment (EQA) is required to ensure patient safety. An international consortium, International Quality Network for Pathology (IQNPath), has delivered a second round of assessment to measure the accuracy of cfDNA testing for lung cancer and the interpretation of the results. METHODS: A collaboration of five EQA provider organisations, all members of IQNPath, have delivered the assessment during 2018-19 to a total of 264 laboratories from 45 countries. Bespoke plasma reference material containing a range of EGFR mutations at varying allelic frequencies were supplied to laboratories for testing and reporting according to routine procedures. The genotyping accuracy and clinical reporting was reviewed against standardised criteria and feedback was provided to participants. RESULTS: The overall genotyping error rate in the EQA was found to be 11.1%. Low allelic frequency samples were the most challenging and were not detected by some testing methods, resulting in critical genotyping errors. This was reflected in higher false negative rates for samples with variant allele frequencies (VAF) rates less than 1.5% compared to higher frequencies. A sample with two different EGFR mutations gave inconsistent detection of both mutations. However, for one sample, where two variants were present at a VAF of less than 1% then both mutations were correctly detected in 145/263 laboratories. Reports often did not address the risk that tumour DNA may have not been tested and limitations of the methodologies provided by participants were insufficient. This was reflected in the average interpretation score for the EQA being 1.49 out of a maximum of 2. CONCLUSIONS: The variability in the standard of genotyping and reporting highlighted the need for EQA and educational guidance in this field to ensure the delivery of high-quality clinical services where testing of cfDNA is the only option for clinical management.
Assuntos
Ácidos Nucleicos Livres , Neoplasias Pulmonares , Receptores ErbB/genética , Frequência do Gene , Humanos , Neoplasias Pulmonares/diagnóstico , Neoplasias Pulmonares/genética , MutaçãoRESUMO
Tumor mutational burden (TMB) has recently been approved as an agnostic biomarker for immune checkpoint inhibitors. However, methods for TMB testing have not yet been standardized. The International Quality Network for Pathology (IQNPath) organized a pilot external quality assessment (EQA) scheme for TMB testing. The aim of this program was the validation of the materials and the procedures for the EQA of this complex biomarker. Five formalin-fixed paraffin-embedded (FFPE) cell lines were selected to mimic the various TMB values observed in clinical practice. The FFPE samples were tested with the FoundationOne CDx (F1CDx) assay as the reference test and three commercially available targeted sequencing panels. Following this internal validation, the five cell lines were sent to 29 laboratories selected on the basis of a previous survey. Nineteen of the 23 laboratories that submitted results (82.6%) used targeted sequencing for TMB estimation. Only two laboratories performed whole exome sequencing (WES) and two assessed TMB by clinical exome. A high variability in the reported TMB values was observed. The variability was higher for samples with the highest TMB value according to the F1CDx test. However, good reproducibility of the TMB score was shown by laboratories using the same panel. The majority of laboratories did not indicate a TMB cut-off value for clinical interpretation. In conclusion, this pilot EQA scheme suggests that it is feasible to run such an EQA program for TMB assessment. However, the results of our pilot highlight the numerous challenges for the standardization of this test.
Assuntos
Biomarcadores Tumorais , Neoplasias , Humanos , Reprodutibilidade dos Testes , Estudos de Viabilidade , Mutação , Biomarcadores Tumorais/genética , Neoplasias/diagnóstico , Neoplasias/genética , Neoplasias/patologia , Carga TumoralRESUMO
While tumour mutation burden (TMB) is emerging as a possible biomarker for immune-checkpoint inhibitors (ICI), methods for testing have not been standardised as yet. In April 2019, the International Quality Network for Pathology (IQN Path) launched a survey to assess the current practice of TMB testing. Of the 127 laboratories that replied, 69 (54.3%) had already introduced TMB analysis for research purposes and/or clinical applications. Fifty laboratories (72.5%) used targeted sequencing, although a number of different panels were employed. Most laboratories tested formalin-fixed paraffin-embedded material (94.2%), while 18/69 (26%) tested also cell-free DNA. Fifty-five laboratories used both single nucleotide variants and indels for TMB calculation; 20 centers included only non-synonymous variants. In conclusion, the data from this survey indicate that multiple global laboratories were capable of rapidly introducing routine clinical TMB testing. However, the variability of testing methods raises concerns about the reproducibility of results among centers.