Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 24(2): e13891, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36601691

RESUMO

PURPOSE: To investigate the usefulness and effectiveness of a dual beam-current transformer (BCTs) design to monitor and record the beam dosimetry output and energy of pulsed electron FLASH (eFLASH) beams in real-time, and to inform on the usefulness of this design for future eFLASH beam control. METHODS: Two BCTs are integrated into the head of a FLASH Mobetron system, one located after the primary scattering foil and the other downstream of the secondary scattering foil. The response of the BCTs was evaluated individually to monitor beam output as a function of dose, scattering conditions, and ability to capture physical beam parameters such as pulse width (PW), pulse repetition frequency (PRF), and dose per pulse (DPP), and in combination to determine beam energy using the ratio of the lower-to-upper BCT signal. RESULTS: A linear relationship was observed between the absorbed dose measured on Gafchromic film and the BCT signals for both the upper and lower BCT (R2  > 0.99). A linear relationship was also observed in the BCT signals as a function of the number of pulses delivered regardless of the PW, DPP, or PRF (R2  > 0.99). The lower-to-upper BCT ratio was found to correlate strongly with the energy of the eFLASH beam due to differential beam attenuation caused by the secondary scattering foil. The BCTs were also able to provide accurate information about the PW, PRF, energy, and DPP for each individual pulse delivered in real-time. CONCLUSION: The dual BCT system integrated within the FLASH Mobetron was shown to be a reliable monitoring system able to quantify accelerator performance and capture all essential physical beam parameters on a pulse-by-pulse basis, and the ratio between the two BCTs was strongly correlated with beam energy. The fast signal readout and processing enables the BCTs to provide real-time information on beam output and energy and is proposed as a system suitable for accurate beam monitoring and control of eFLASH beams.


Assuntos
Elétrons , Dosagem Radioterapêutica , Humanos , Radiometria
2.
ArXiv ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38827455

RESUMO

Background & Purpose: FLASH or ultra-high dose rate (UHDR) radiation therapy (RT) has gained attention in recent years for its ability to spare normal tissues relative to conventional dose rate (CDR) RT in various preclinical trials. However, clinical implementation of this promising treatment option has been limited because of the lack of availability of accelerators capable of delivering UHDR RT. Commercial options are finally reaching the market that produce electron beams with average dose rates of up to 1000 Gy/s. We established a framework for the acceptance, commissioning, and periodic quality assurance (QA) of electron FLASH units and present an example of commissioning. Methods: A protocol for acceptance, commissioning, and QA of UHDR linear accelerators was established by combining and adapting standards and professional recommendations for standard linear accelerators based on the experience with UHDR at four clinical centers that use different UHDR devices. Non-standard dosimetric beam parameters considered included pulse width, pulse repetition frequency, dose per pulse, and instantaneous dose rate, together with recommendations on how to acquire these measurements. Results: The 6- and 9-MeV beams of an UHDR electron device were commissioned by using this developed protocol. Measurements were acquired with a combination of ion chambers, beam current transformers (BCTs), and dose-rate-independent passive dosimeters. The unit was calibrated according to the concept of redundant dosimetry using a reference setup. Conclusions: This study provides detailed recommendations for the acceptance testing, commissioning, and routine QA of low-energy electron UHDR linear accelerators. The proposed framework is not limited to any specific unit, making it applicable to all existing eFLASH units in the market. Through practical insights and theoretical discourse, this document establishes a benchmark for the commissioning of UHDR devices for clinical use.

3.
Clin Transl Radiat Oncol ; 46: 100760, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38510980

RESUMO

Purpose: MR-guided radiotherapy (MRgRT) has the advantage of utilizing high soft tissue contrast imaging to track daily changes in target and critical organs throughout the entire radiation treatment course. Head and neck (HN) stereotactic body radiation therapy (SBRT) has been increasingly used to treat localized lesions within a shorter timeframe. The purpose of this study is to examine the dosimetric difference between the step-and-shot intensity modulated radiation therapy (IMRT) plans on Elekta Unity and our clinical volumetric modulated arc therapy (VMAT) plans on Varian TrueBeam for HN SBRT. Method: Fourteen patients treated on TrueBeam sTx with VMAT treatment plans were re-planned in the Monaco treatment planning system for Elekta Unity MR-Linac (MRL). The plan qualities, including target coverage, conformity, homogeneity, nearby critical organ doses, gradient index and low dose bath volume, were compared between VMAT and Monaco IMRT plans. Additionally, we evaluated the Unity adaptive plans of adapt-to-position (ATP) and adapt-to-shape (ATS) workflows using simulated setup errors for five patients and assessed the outcomes of our treated patients. Results: Monaco IMRT plans achieved comparable results to VMAT plans in terms of target coverage, uniformity and homogeneity, with slightly higher target maximum and mean doses. The critical organ doses in Monaco IMRT plans all met clinical goals; however, the mean doses and low dose bath volumes were higher than in VMAT plans. The adaptive plans demonstrated that the ATP workflow may result in degraded target coverage and OAR doses for HN SBRT, while the ATS workflow can maintain the plan quality. Conclusion: The use of Monaco treatment planning and online adaptation can achieve dosimetric results comparable to VMAT plans, with the additional benefits of real-time tracking of target volume and nearby critical structures. This offers the potential to treat aggressive and variable tumors in HN SBRT and improve local control and treatment toxicity.

4.
Clin Cancer Res ; 27(23): 6432-6444, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34518309

RESUMO

PURPOSE: Although remarkably effective in some patients, precision medicine typically induces only transient responses despite initial absence of resistance-conferring mutations. Using BRAF-mutated myeloma as a model for resistance to precision medicine we investigated if BRAF-mutated cancer cells have the ability to ensure their survival by rapidly adapting to BRAF inhibitor treatment. EXPERIMENTAL DESIGN: Full-length single-cell RNA (scRNA) sequencing (scRNA-seq) was conducted on 3 patients with BRAF-mutated myeloma and 1 healthy donor. We sequenced 1,495 cells before, after 1 week, and at clinical relapse to BRAF/MEK inhibitor treatment. We developed an in vitro model of dabrafenib resistance using genetically homogeneous single-cell clones from two cell lines with established BRAF mutations (U266, DP6). Transcriptional and epigenetic adaptation in resistant cells were defined by RNA-seq and H3K27ac chromatin immunoprecipitation sequencing (ChIP-seq). Mitochondrial metabolism was characterized by metabolic flux analysis. RESULTS: Profiling by scRNA-seq revealed rapid cellular state changes in response to BRAF/MEK inhibition in patients with myeloma and cell lines. Transcriptional adaptation preceded detectable outgrowth of genetically discernible drug-resistant clones and was associated with widespread enhancer remodeling. As a dominant vulnerability, dependency on oxidative phosphorylation (OxPhos) was induced. In treated individuals, OxPhos was activated at the time of relapse and showed inverse correlation to MAPK activation. Metabolic flux analysis confirmed OxPhos as a preferential energetic resource of drug-persistent myeloma cells. CONCLUSIONS: This study demonstrates that cancer cells have the ability to rapidly adapt to precision treatments through transcriptional state changes, epigenetic adaptation, and metabolic rewiring, thus facilitating the development of refractory disease while simultaneously exposing novel vulnerabilities.


Assuntos
Melanoma , Mieloma Múltiplo , Resistencia a Medicamentos Antineoplásicos , Humanos , Melanoma/tratamento farmacológico , Mieloma Múltiplo/tratamento farmacológico , Mieloma Múltiplo/genética , Mutação , Recidiva Local de Neoplasia/tratamento farmacológico , Inibidores de Proteínas Quinases/farmacologia , Inibidores de Proteínas Quinases/uso terapêutico , Proteínas Proto-Oncogênicas B-raf , Análise de Célula Única
5.
Radiat Oncol ; 15(1): 14, 2020 Jan 14.
Artigo em Inglês | MEDLINE | ID: mdl-31937336

RESUMO

INTRODUCTION: Limited stage small cell lung cancer (LS-SCLC) has a poor prognosis. Additional prognostic markers are needed for risk-stratification and treatment intensification. This study compares quantitative CT-based volumetric tumor measurements versus International Association for the Study of Lung Cancer (IASLC) TNM staging to predict outcomes. MATERIALS & METHODS: A cohort of 105 patients diagnosed with LS-SCLC and treated with chemoradiation (CRT) from 2000 to 2013 were analyzed retrospectively. Patients were staged by the Union for International Cancer Control (UICC) TNM Classification, 8th edition. Tumor volumes and diameters were extracted from radiation planning CT imaging. Univariable and multivariable models were used to analyze relationships between CT features and overall survival (OS), locoregional recurrence (LRR), in-field LRR, any progression, and distant metastasis (DM). RESULTS: Median follow-up was 21.3 months. Two-year outcomes were as follows: 38% LRR, 31% in-field LRR, 52% DM, 62% any progression, and 47% OS (median survival 16.5 months). On univariable analysis, UICC T-stage and N-stage were not associated with any clinical outcome. UICC overall stage was only statistically associated with in-field LRR. One imaging feature (3D maximum tumor diameter) was found to be significantly associated with LRR (HR 1.10, p = 0.003), in-field LRR (HR 1.10, p = 0.007), DM (HR 1.10, p = 0.02), any progression (HR 1.10, p = 0.008), and OS (HR 1.10, p = 0.03). On multivariable analysis, this feature remained significantly associated with all outcomes. CONCLUSION: For LS-SCLC, quantitative CT-based volumetric tumor measurements were significantly associated with outcomes after CRT and may be better predictors of outcome than TNM stage.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Neoplasias Pulmonares/diagnóstico por imagem , Planejamento da Radioterapia Assistida por Computador , Carcinoma de Pequenas Células do Pulmão/diagnóstico por imagem , Carcinoma de Pequenas Células do Pulmão/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Quimiorradioterapia , Feminino , Humanos , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/radioterapia , Masculino , Pessoa de Meia-Idade , Estadiamento de Neoplasias , Prognóstico , Estudos Retrospectivos , Carcinoma de Pequenas Células do Pulmão/patologia , Resultado do Tratamento , Carga Tumoral/efeitos da radiação
6.
Radiother Oncol ; 136: 169-175, 2019 07.
Artigo em Inglês | MEDLINE | ID: mdl-31015121

RESUMO

BACKGROUND AND PURPOSE: To compare time-dependent changes in lung parenchyma of early-stage non-small cell lung carcinoma (NSCLC) patients after stereotactic body radiation therapy with protons (SBPT) or photons (SBRT). MATERIALS AND METHOD: We retrospectively identified NSCLC patients treated with SBPT and matched each one with a SBRT patient by patient, tumor, and treatment characteristics. Lung parenchyma on serial post-treatment chest computer tomography (CT) scans was deformably registered with the treatment plan to analyze lung density changes as function of dose, quantified by Houndsfield Unit (HU)/Gy. A thoracic radiologist also evaluated the CTs using an established grading system. RESULTS: We matched 23 SBPT/SBRT pairs, including 5 patients treated with both modalities (internally matched cohort). Normal lung response following SBPT significantly increased in the early time period (CTs acquired <6 months, median 3 months) post-treatment, and then did not change significantly in the later time period (CTs acquired 6-14 months, median 9 months). For SBRT, the normal lung response was similar to SBPT in the early time period, but then increased significantly from the early to the late time period (p = 0.007). These differences were most pronounced in sensitive (response >6 HU/Gy) patients and in the internally matched cohort. However, there was no significant difference in the maximum observed response in the entire cohort over all time periods, median 3.4 [IQR, 1.0-5.4] HU/Gy (SBPT) versus 2.5 [1.6-5.2] HU/Gy (SBRT). Qualitative radiological evaluation was highly correlated with the quantitative analysis (p < 0.0001). CONCLUSION: While there was no significant difference in maximum response after SBPT versus SBRT, dose-defined lung inflammation occurred earlier after proton irradiation. Further investigation is warranted into the mechanisms of inflammation and therapeutic consequences after proton versus photon irradiation.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/radioterapia , Inflamação/etiologia , Neoplasias Pulmonares/radioterapia , Pulmão/efeitos da radiação , Fótons/uso terapêutico , Terapia com Prótons/efeitos adversos , Radiocirurgia/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Feminino , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Fótons/efeitos adversos , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA