Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
1.
Circ Res ; 134(3): 328-342, 2024 02 02.
Artigo em Inglês | MEDLINE | ID: mdl-38300981

RESUMO

Cardiac arrest is the leading cause of death in the more economically developed countries. Ventricular tachycardia associated with myocardial infarct is a prominent cause of cardiac arrest. Ventricular arrhythmias occur in 3 phases of infarction: during the ischemic event, during the healing phase, and after the scar matures. Mechanisms of arrhythmias in these phases are distinct. This review focuses on arrhythmia mechanisms for ventricular tachycardia in mature myocardial scar. Available data have shown that postinfarct ventricular tachycardia is a reentrant arrhythmia occurring in circuits found in the surviving myocardial strands that traverse the scar. Electrical conduction follows a zigzag course through that area. Conduction velocity is impaired by decreased gap junction density and impaired myocyte excitability. Enhanced sympathetic tone decreases action potential duration and increases sarcoplasmic reticular calcium leak and triggered activity. These elements of the ventricular tachycardia mechanism are found diffusely throughout scar. A distinct myocyte repolarization pattern is unique to the ventricular tachycardia circuit, setting up conditions for classical reentry. Our understanding of ventricular tachycardia mechanisms continues to evolve as new data become available. The ultimate use of this information would be the development of novel diagnostics and therapeutics to reliably identify at-risk patients and prevent their ventricular arrhythmias.


Assuntos
Parada Cardíaca , Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Cicatriz , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Arritmias Cardíacas/complicações , Infarto do Miocárdio/complicações , Parada Cardíaca/complicações , Eletrocardiografia
2.
J Physiol ; 2023 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-37060278

RESUMO

Personalized, image-based computational heart modelling is a powerful technology that can be used to improve patient-specific arrhythmia risk stratification and ventricular tachycardia (VT) ablation targeting. However, most state-of-the-art methods still require manual interactions by expert users. The goal of this study is to evaluate the feasibility of an automated, deep learning-based workflow for reconstructing personalized computational electrophysiological heart models to guide patient-specific treatment of VT. Contrast-enhanced computed tomography (CE-CT) images with expert ventricular myocardium segmentations were acquired from 111 patients across five cohorts from three different institutions. A deep convolutional neural network (CNN) for segmenting left ventricular myocardium from CE-CT was developed, trained and evaluated. From both CNN-based and expert segmentations in a subset of patients, personalized electrophysiological heart models were reconstructed and rapid pacing was used to induce VTs. CNN-based and expert segmentations were more concordant in the middle myocardium than in the heart's base or apex. Wavefront propagation during pacing was similar between CNN-based and original heart models. Between most sets of heart models, VT inducibility was the same, the number of induced VTs was strongly correlated, and VT circuits co-localized. Our results demonstrate that personalized computational heart models reconstructed from deep learning-based segmentations even with a small training set size can predict similar VT inducibility and circuit locations as those from expertly-derived heart models. Hence, a user-independent, automated framework for simulating arrhythmias in personalized heart models could feasibly be used in clinical settings to aid VT risk stratification and guide VT ablation therapy. KEY POINTS: Personalized electrophysiological heart modelling can aid in patient-specific ventricular tachycardia (VT) risk stratification and VT ablation targeting. Current state-of-the-art, image-based heart models for VT prediction require expert-dependent, manual interactions that may not be accessible across clinical settings. In this study, we develop an automated, deep learning-based workflow for reconstructing personalized heart models capable of simulating arrhythmias and compare its predictions with that of expert-generated heart models. The number and location of VTs was similar between heart models generated from the deep learning-based workflow and expert-generated heart models. These results demonstrate the feasibility of using an automated computational heart modelling workflow to aid in VT therapeutics and has implications for generalizing personalized computational heart technology to a broad range of clinical centres.

3.
J Card Fail ; 29(8): 1135-1145, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37062472

RESUMO

BACKGROUND: Although sex- and race-based patterns have been described in the extracardiac organ involvement of sarcoidosis, cardiac sarcoidosis (CS)-specific studies are lacking. METHODS: We studied CS presentation, treatment and outcomes based on sex and race in a tertiary-center cohort. Multivariable adjusted Cox proportional hazards and survival analyses were performed for primary composite outcomes (left ventricular assist device, heart transplantation, all-cause death) and for secondary outcomes (ventricular arrhythmia and all-cause death. RESULTS: We identified 252 patients with CS (108 female, 109 Black). At presentation with CS, females vs males (P = 0.001) and Black vs White individuals (P = 0.001) more commonly had symptomatic heart failure (HF), with HF most common in Black females (ANOVA P < 0.001). Treatment differences included more corticosteroid use (90% vs 79%; P = 0.020), higher 1-year prednisone dosage (13 vs 10 mg; P = 0.003) and less frequent early steroid-sparing agent use in males (29% vs 40%; P = 0.05). Black participants more frequently received a steroid-sparing agent (75% vs 60%; P = 0.023). Composite outcome-free survival did not differ by sex or race. Male sex had an adjusted hazard ratio of 2.34 (95% CI 1.13, 4.80; P = 0.021) for ventricular arrhythmia. CONCLUSION: CS course may differ by sex and race and may contribute to distinct clinical CS phenotypes.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Miocardite , Sarcoidose , Masculino , Feminino , Humanos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Cardiomiopatias/diagnóstico , Cardiomiopatias/tratamento farmacológico , Fatores Raciais , Estudos Retrospectivos , Sarcoidose/diagnóstico , Sarcoidose/tratamento farmacológico , Sarcoidose/epidemiologia , Miocardite/complicações , Arritmias Cardíacas , Resultado do Tratamento
4.
Europace ; 25(1): 223-235, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36006658

RESUMO

AIMS: Multiple wavefront pacing (MWP) and decremental pacing (DP) are two electroanatomic mapping (EAM) strategies that have emerged to better characterize the ventricular tachycardia (VT) substrate. The aim of this study was to assess how well MWP, DP, and their combination improve identification of electrophysiological abnormalities on EAM that reflect infarct remodelling and critical VT sites. METHODS AND RESULTS: Forty-eight personalized computational heart models were reconstructed using images from post-infarct patients undergoing VT ablation. Paced rhythms were simulated by delivering an initial (S1) and an extra-stimulus (S2) from one of 100 locations throughout each heart model. For each pacing, unipolar signals were computed along the myocardial surface to simulate substrate EAM. Six EAM features were extracted and compared with the infarct remodelling and critical VT sites. Concordance of S1 EAM features between different maps was lower in hearts with smaller amounts of remodelling. Incorporating S1 EAM features from multiple maps greatly improved the detection of remodelling, especially in hearts with less remodelling. Adding S2 EAM features from multiple maps decreased the number of maps required to achieve the same detection accuracy. S1 EAM features from multiple maps poorly identified critical VT sites. However, combining S1 and S2 EAM features from multiple maps paced near VT circuits greatly improved identification of critical VT sites. CONCLUSION: Electroanatomic mapping with MWP is more advantageous for characterization of substrate in hearts with less remodelling. During substrate EAM, MWP and DP should be combined and delivered from locations proximal to a suspected VT circuit to optimize identification of the critical VT site.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/cirurgia , Miocárdio , Infarto/cirurgia
5.
Europace ; 25(2): 496-505, 2023 02 16.
Artigo em Inglês | MEDLINE | ID: mdl-36519747

RESUMO

AIMS: Post-infarct myocardium contains viable corridors traversing scar or lipomatous metaplasia (LM). Ventricular tachycardia (VT) circuitry has been separately reported to associate with corridors that traverse LM and with repolarization heterogeneity. We examined the association of corridor activation recovery interval (ARI) and ARI dispersion with surrounding tissue type. METHODS AND RESULTS: The cohort included 33 post-infarct patients from the prospective Intra-Myocardial Fat Deposition and Ventricular Tachycardia in Cardiomyopathy (INFINITY) study. We co-registered scar and corridors from late gadolinium enhanced magnetic resonance, and LM from computed tomography with intracardiac electrogram locations. Activation recovery interval was calculated during sinus or ventricular pacing, as the time interval from the minimum derivative within the QRS to the maximum derivative within the T-wave on unipolar electrograms. Regional ARI dispersion was defined as the standard deviation (SD) of ARI per AHA segment (ARISD). Lipomatous metaplasia exhibited higher ARI than scar [325 (interquartile range 270-392) vs. 313 (255-374), P < 0.001]. Corridors critical to VT re-entry were more likely to traverse through or near LM and displayed prolonged ARI compared with non-critical corridors [355 (319-397) vs. 302 (279-333) ms, P < 0.001]. ARISD was more closely associated with LM than with scar (likelihood ratio χ2 50 vs. 12, and 4.2-unit vs. 0.9-unit increase in 0.01*Log(ARISD) per 1 cm2 increase per AHA segment). Additionally, LM and scar exhibited interaction (P < 0.001) in their association with ARISD. CONCLUSION: Lipomatous metaplasia is closely associated with prolonged local action potential duration of corridors and ARI dispersion, which may facilitate the propensity of VT circuit re-entry.


Assuntos
Cardiomiopatias , Infarto do Miocárdio , Taquicardia Ventricular , Humanos , Cicatriz/diagnóstico por imagem , Cicatriz/complicações , Estudos Prospectivos , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/complicações , Arritmias Cardíacas/complicações , Infarto do Miocárdio/complicações , Infarto do Miocárdio/diagnóstico
6.
J Card Fail ; 28(1): 113-132, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34260889

RESUMO

The prevalence of sarcoidosis-related cardiomyopathy is increasing. Sarcoidosis impacts cardiac function through granulomatous infiltration of the heart, resulting in conduction disease, arrhythmia, and/or heart failure. The diagnosis of cardiac sarcoidosis (CS) can be challenging and requires clinician awareness as well as differentiation from overlapping diagnostic phenotypes, such as other forms of myocarditis and arrhythmogenic cardiomyopathy. Clinical manifestations, extracardiac involvement, histopathology, and advanced cardiac imaging can all lend support to a diagnosis of CS. The mainstay of therapy for CS is immunosuppression; however, no prospective clinical trials exist to guide management. Patients may progress to developing advanced heart failure or ventricular arrhythmia, for which ventricular assist device therapies or heart transplantation may be considered. The existing knowledge gaps in CS call for an interdisciplinary approach to both patient care and future investigation to improve mechanistic understanding and therapeutic strategies.


Assuntos
Cardiomiopatias , Insuficiência Cardíaca , Transplante de Coração , Miocardite , Sarcoidose , Cardiomiopatias/diagnóstico , Cardiomiopatias/epidemiologia , Cardiomiopatias/etiologia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Insuficiência Cardíaca/etiologia , Humanos , Sarcoidose/complicações , Sarcoidose/diagnóstico , Sarcoidose/epidemiologia
7.
J Electrocardiol ; 72: 6-12, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35220047

RESUMO

BACKGROUND: Accurate localization of premature ventricular contractions (PVC) focus is a prerequisite to successful catheter ablation. OBJECTIVE: The objective was to evaluate the software View Into Ventricular Onset (VIVO) accuracy at locating the anatomical origins for premature ventricular contractions. The VIVO device noninvasively creates a model of the patient's heart and torso, with exact locations of 12­lead ECG electrodes, and applies a mathematical algorithm from surface signals to determine the origin of the arrhythmia. We sought to compare the agreement between VIVO-predicted locations to invasive electroanatomical mapping results. METHODS: 51 consecutive patients who presented for PVC ablations at the study centers were recruited. VIVO images were collected at baseline preprocedure and all patients underwent invasive electroanatomical activation mapping of the clinical arrhythmia. Pacing was performed in pre-specified locations in the right and/or left ventricle. The successful sites of ablation and the pacing locations were compared to VIVO predicted locations. The results were adjudicated by physician experts in a blinded fashion. RESULTS: Seven patients were excluded from analyses. VIVO accurately identified the origin of the clinical premature ventricular contractions in 44/44 patients (100.00%). The accuracy in identifying the paced location for all patients (right and left sides of the heart) was 99.5% using the VIVO system. No adverse events were reported. CONCLUSIONS: VIVO is a novel noninvasive system that could be used to help guide ablation procedures with a high degree of accuracy. The VIVO algorithm is easy to use and may be useful in the workflow for ventricular arrhythmia ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Complexos Ventriculares Prematuros , Eletrocardiografia/métodos , Ventrículos do Coração/cirurgia , Humanos , Estudos Prospectivos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia
8.
J Card Fail ; 27(12): 1348-1358, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34166800

RESUMO

BACKGROUND: Cardiac sarcoidosis (CS) is a major cause of morbidity and mortality in patients with systemic sarcoidosis. Steroid-sparing agents are increasingly used, despite a lack of randomized trials or published guidelines to direct treatment. METHODS AND RESULTS: This retrospective study included 77 patients with CS treated with prednisone monotherapy (n = 32) or a combination with mycophenolate mofetil (n = 45) between 2003 and 2018. Baseline characteristics and clinical outcomes were evaluated. The mean patient age was 53 ± 11 years at CS diagnosis, 66.2% were male, and 35.1% were Black. The total exposure to maximum prednisone dose (initial prednisone dose × days at dose) was lower in the combination therapy group (1440 mg [interquartile range (IQR), 1200-2760 mg] vs 2710 mg [IQR, 1200-5080 mg]; P = .06). On 18F-fluorodeoxyglucose positron emission tomography scans, both groups demonstrated a significant decrease in the cardiac maximum standardized uptake value after treatment: a median decrease of 3.9 (IQR 2.7-9.0, P = .002) and 2.9 (IQR 0-5.0, P = .001) for prednisone monotherapy and combination therapy, respectively. Most patients experienced improvement or complete resolution in qualitative cardiac 18F-fluorodeoxyglucose uptake (92.3% and 70.4% for the prednisone and combination therapy groups, respectively). Mycophenolate mofetil was well tolerated. CONCLUSIONS: Mycophenolate mofetil in combination with prednisone for the treatment of CS may minimize corticosteroid exposure and decrease cardiac inflammation without significant adverse effects.


Assuntos
Insuficiência Cardíaca , Sarcoidose , Adulto , Humanos , Imunossupressores/uso terapêutico , Masculino , Pessoa de Meia-Idade , Ácido Micofenólico/uso terapêutico , Prednisona/uso terapêutico , Estudos Retrospectivos , Sarcoidose/tratamento farmacológico
9.
Pacing Clin Electrophysiol ; 44(12): 2067-2074, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34766627

RESUMO

BACKGROUND: Patients with cardiac sarcoidosis (CS) are at increased risk of life-threatening ventricular arrhythmias (VA). Current approaches to risk stratification have limited predictive value. OBJECTIVES: To assess the utility of spatial dispersion analysis of late gadolinium enhancement cardiac magnetic resonance (LGE-CMR), as a quantitative measure of myocardial tissue heterogeneity, in risk stratifying patients with CS for VA and death. METHODS: Sixty two patients with CS underwent LGE-CMR. LGE images were segmented and dispersion maps of the left and right ventricles were generated as follows. Based on signal intensity (SI), each pixel was categorized as abnormal (SI ≥3SD above the mean), intermediate (SI 1-3 SD above the mean) or normal (SI <1SD above the mean); and each pixel was then assigned a value of 0 to 8 based on the number of adjacent pixels of a different category. Average dispersion score was calculated for each patient. The primary endpoint was VA during follow up. The composite of VA or death was assessed as a secondary endpoint. RESULTS: During 4.7 ± 3.5 years of follow up, six patients had VA, and five without documented VA died. Average dispersion score was significantly higher in patients with VA versus those without (0.87 ± 0.08 vs. 0.71 ± 0.16; p = .002) and in patients with events versus those without (0.83 ± 0.08 vs. 0.70 ± 0.16; p = .003). Patients at higher tertiles of dispersion score had a higher incidence of VA (p = .03) and the composite of VA or death (p = .01). CONCLUSIONS: Increased substrate heterogeneity, quantified by spatial dispersion analysis of LGE-CMR, may be helpful in risk-stratifying patients with CS for adverse events, including life-threatening arrhythmias.


Assuntos
Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/etiologia , Imageamento por Ressonância Magnética/métodos , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Meios de Contraste , Feminino , Gadolínio , Humanos , Interpretação de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Medição de Risco
10.
Pacing Clin Electrophysiol ; 44(3): 432-441, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33527422

RESUMO

INTRODUCTION: We recently developed two noninvasive methodologies to help guide VT ablation: population-derived automated VT exit localization (PAVEL) and virtual-heart arrhythmia ablation targeting (VAAT). We hypothesized that while very different in their nature, limitations, and type of ablation targets (substrate-based vs. clinical VT), the image-based VAAT and the ECG-based PAVEL technologies would be spatially concordant in their predictions. OBJECTIVE: The objective is to test this hypothesis in ischemic cardiomyopathy patients in a retrospective feasibility study. METHODS: Four post-infarct patients who underwent LV VT ablation and had pre-procedural LGE-CMRs were enrolled. Virtual hearts with patient-specific scar and border zone identified potential VTs and ablation targets. Patient-specific PAVEL based on a population-derived statistical method localized VT exit sites onto a patient-specific 238-triangle LV endocardial surface. RESULTS: Ten induced VTs were analyzed and 9-exit sites were localized by PAVEL onto the patient-specific LV endocardial surface. All nine predicted VT exit sites were in the scar border zone defined by voltage mapping and spatially correlated with successful clinical lesions. There were 2.3 ± 1.9 VTs per patient in the models. All five VAAT lesions fell within regions ablated clinically. VAAT targets correlated well with 6 PAVEL-predicted VT exit sites. The distance between the center of the predicted VT-exit-site triangle and nearest corresponding VAAT ablation lesion was 10.7 ± 7.3 mm. CONCLUSIONS: VAAT targets are concordant with the patient-specific PAVEL-predicted VT exit sites. These findings support investigation into combining these two complementary technologies as a noninvasive, clinical tool for targeting clinically induced VTs and regions likely to harbor potential VTs.


Assuntos
Ablação por Cateter/métodos , Isquemia Miocárdica/cirurgia , Taquicardia Ventricular/cirurgia , Idoso de 80 Anos ou mais , Eletrocardiografia , Estudos de Viabilidade , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Isquemia Miocárdica/diagnóstico por imagem , Modelagem Computacional Específica para o Paciente , Estudos Retrospectivos , Taquicardia Ventricular/diagnóstico por imagem
11.
BMC Nephrol ; 22(1): 199, 2021 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-34044764

RESUMO

BACKGROUND: Patients receiving dialysis face a high risk of cardiovascular disease, arrhythmia and sudden cardiac death. Few patients, however, are aware of this risk. Implantable cardiac monitors are currently available for clinical use and can continuously monitor cardiac rhythms without the need for transvenous leads. Our goal was to gauge patients' and family members' perceptions of these risks and to identify their concerns about cardiac monitors. METHODS: Two 90-minute focus groups were conducted: one with patients receiving in-center hemodialysis and one with their family members. Trained moderators assessed: (1) knowledge of cardiovascular disease; (2) cardiovascular disease risk in dialysis; (3) risk of death due to cardiovascular disease; (4) best ways to convey this risk to patients/families; and (5) concerns about cardiac monitors. The sessions were audiotaped, transcribed, and independently analyzed by two reviewers to identify core themes. Emblematic quotations were chosen to illustrate the final themes. RESULTS: Nine adult patients and three family members participated. Patients felt education was inadequate and had little knowledge of arrhythmias. Patients'/families' concerns regarding cardiac monitors were related to adverse effects, the notification process, and cosmetic effects. Patients/families felt that nephrologists, not dialysis staff, would be the best source for education. CONCLUSIONS: The preliminary data from this small study population suggest that patients/families are not well aware of the high risk of arrhythmia and sudden cardiac death in dialysis. Further investigation is required to gauge this awareness among patients/families and to assess their impressions of implantable cardiac monitors for arrhythmia detection and management.


Assuntos
Arritmias Cardíacas/etiologia , Morte Súbita Cardíaca/etiologia , Eletrocardiografia Ambulatorial/instrumentação , Conhecimentos, Atitudes e Prática em Saúde , Falência Renal Crônica/terapia , Educação de Pacientes como Assunto , Diálise Renal/efeitos adversos , Adulto , Idoso , Família , Feminino , Grupos Focais , Humanos , Falência Renal Crônica/complicações , Masculino , Pessoa de Meia-Idade , Pacientes , Projetos Piloto
12.
Pacing Clin Electrophysiol ; 43(1): 2-9, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31691986

RESUMO

BACKGROUND: Pacemaker battery depletion triggers alert for replacement notification and results in automatic reprogramming, which has been shown to be associated with relevant cardiorespiratory symptoms and adverse clinical events. OBJECTIVE: Determine if electrocardiogram (ECG) pacing features may be predictive of pacemaker battery depletion and clinical risk. METHODS: This is an ECG substudy of a cohort analysis of 298 subjects referred for pacemaker generator replacement from 2006 to 2017. Electronic medical record review was performed; clinical, ECG, and pacemaker characteristics were abstracted. We applied two ECG prediction rules for pacemaker battery depletion that are relevant to all major pacemaker manufacturers except Boston Scientific and MicroPort: (1) atrial pacing not at a multiple of 10 and (2) nonsynchronous ventricular pacing not at a multiple of 10, to determine diagnostic sensitivity, specificity, and risk in applicable ECG subjects. RESULTS: We excluded 32 subjects not at replacement notification or duplicate surgeries. Overall, 176 of 266 subjects (66.2%) demonstrated atrial pacing or nonsynchronous ventricular pacing on preoperative ECG. When utilizing both rules, 139 of 176 preoperative ECGs and 12 of 163 postoperative ECGs met criteria for battery depletion yielding reasonable sensitivity (79.0%), high specificity (92.6%), and a positive likelihood ratio of 11.6:1. These rules were associated with significant increase in cardiorespiratory symptoms (P < .001) and adverse clinical events (P < .025). CONCLUSIONS: The "Rules of Ten" provided reasonable sensitivity and specificity for detecting replacement notification in pacemaker subjects with an applicable ECG. This ECG tool may help clinicians identify most patients with pacemaker battery depletion at significant clinical risk.


Assuntos
Fontes de Energia Elétrica , Eletrocardiografia/métodos , Falha de Equipamento , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
13.
Circulation ; 138(12): 1253-1264, 2018 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-30354431

RESUMO

The diagnosis of cardiac sarcoidosis (CS), especially in cases where there is limited or no extracardiac involvement, is challenging. Patients with CS are at increased risk of ventricular arrhythmias and sudden cardiac death. Several techniques for risk stratification for sudden cardiac death have been proposed in this population, including advanced cardiac imaging and electrophysiology study. Clinical ventricular arrhythmias in patients with CS may be treated with immunosuppressant therapy, antiarrhythmic drugs, catheter ablation, or implantable cardioverter-defibrillator placement. This article will provide an update on techniques for diagnosing CS, risk stratifying patients with CS for sudden cardiac death, and treating patients with CS with ventricular arrhythmias, focusing on evidence that has become available since publication of the 2014 Heart Rhythm Society Expert Consensus Statement on the Diagnosis and Management of Arrhythmias Associated With Cardiac Sarcoidosis.


Assuntos
Cardiomiopatias/complicações , Morte Súbita Cardíaca/etiologia , Sarcoidose/complicações , Taquicardia Ventricular/etiologia , Antiarrítmicos/uso terapêutico , Cardiomiopatias/diagnóstico , Cardiomiopatias/tratamento farmacológico , Cardiomiopatias/mortalidade , Ablação por Cateter , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Humanos , Imunossupressores/uso terapêutico , Valor Preditivo dos Testes , Medição de Risco , Fatores de Risco , Sarcoidose/diagnóstico , Sarcoidose/tratamento farmacológico , Sarcoidose/mortalidade , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/terapia , Resultado do Tratamento
14.
J Cardiovasc Electrophysiol ; 30(10): 1967-1976, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31328324

RESUMO

BACKGROUND: Patients with cardiac sarcoidosis (CS) may present with arrhythmic events (AE): atrioventricular block (AVB) and/ or ventricular arrhythmias (VA). We sought to: (a) use regional analysis of cardiac magnetic resonance imaging (CMR) to describe anatomic and functional phenotypes of patients with CS and AE; (b) Assess the association of regional CMR abnormalities with the combined endpoint of death, heart transplantation (HT) and AE; and (c) use machine learning (ML) to predict the combined endpoint based on CMR features. METHODS: we included 76 patients with CS and CMR. We analyzed cine images to determine regional longitudinal (LS) and radial strain (RS); and late gadolinium enhancement imaging to determine regional scar burden (%scar). RESULTS: Patients with AVB (n = 7), compared with those without, had higher %scar in the anterior (21.8 ± 27.4 vs 5.1 ± 8.9; P = 0.0005) and anteroseptal (19.3 ± 24.5 vs 3.5 ± 5.5; P < .0001) walls. Patients with VA (n = 12), compared with those without, had higher %scar in the basal inferoseptum (20.4 ± 30.8 vs 8.3 ± 13.4; P = .03). During mean follow-up of 4.4 ± 3.3 years, four patients died or underwent HT; eight had VA; and zero developed AVB. Multiple regional abnormalities were associated with the combined endpoint, including scar in the anteroseptal wall (HR 1.06 [1.02-1.09] per 1%scar increase, P = .002). The ML algorithm predicted the combined endpoint with a C-statistic of 0.91. CONCLUSION: Regional CMR abnormalities are associated with AE in patients with CS.


Assuntos
Bloqueio Atrioventricular/etiologia , Cardiomiopatias/diagnóstico por imagem , Morte Súbita Cardíaca/etiologia , Imagem Cinética por Ressonância Magnética , Sarcoidose/diagnóstico por imagem , Taquicardia Ventricular/etiologia , Fibrilação Ventricular/etiologia , Função Ventricular Esquerda , Adulto , Idoso , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/mortalidade , Bloqueio Atrioventricular/fisiopatologia , Cardiomiopatias/complicações , Cardiomiopatias/mortalidade , Cardiomiopatias/fisiopatologia , Meios de Contraste/administração & dosagem , Progressão da Doença , Feminino , Fibrose , Gadolínio DTPA/administração & dosagem , Transplante de Coração , Humanos , Aprendizado de Máquina , Masculino , Pessoa de Meia-Idade , Miocárdio/patologia , Compostos Organometálicos/administração & dosagem , Valor Preditivo dos Testes , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/mortalidade , Sarcoidose/fisiopatologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/mortalidade , Taquicardia Ventricular/fisiopatologia , Fibrilação Ventricular/diagnóstico , Fibrilação Ventricular/mortalidade , Fibrilação Ventricular/fisiopatologia
16.
J Cardiovasc Electrophysiol ; 29(2): 239-245, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29131442

RESUMO

INTRODUCTION: Catheter ablation is common for patients with symptomatic, drug-refractory atrial fibrillation (AF). Obesity is a known risk factor for incident AF. The impact of obesity on AF ablation outcomes is incompletely understood. We sought to determine the impact of elevated body mass index (BMI) on pulmonary vein isolation (PVI) procedural outcomes and associated complications. METHODS AND RESULTS: We evaluated patients undergoing PVI from 2001 to 2015, dividing them into four groups: normal weight (BMI ≥ 18.5 to < 25), overweight (BMI ≥ 25 to < 30), obese (BMI > 30 to < 40), and morbidly obese (BMI ≥ 40). Demographic and procedural characteristics, complications, and ablation outcomes were compared among groups. A total of 701 patients (146 time-matched controls, 227 overweight, 244 obese, and 84 morbidly obese) with complete demographic, procedural, and follow-up data were included. Increasing BMI correlated positively with HTN, OSA, CHA2 DS2 -VASC score, and persistent AF (P ≤ 0.001 for all associations). Radiofrequency application time and intraprocedural heparin dose increased with BMI (P ≤ 0.001). Arrhythmia recurrence at 1 year was 39.9% in controls, while higher in all high-BMI groups (overweight, 51.3%; obese, 57%; morbidly obese, 58.1 %; P  =  0.007 for all versus controls). Impact of BMI on AF recurrence was not seen in persistent AF patients. Complication rates across groups were similar. CONCLUSIONS: AF recurrence after catheter ablation is higher in overweight, obese, and morbidly obese patients comparing to normal-weight controls, driven primarily by outcomes differences in paroxysmal AF patients. Complications were not associated with increased BMI.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Obesidade/complicações , Sobrepeso/complicações , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Índice de Massa Corporal , Feminino , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Obesidade/diagnóstico , Sobrepeso/diagnóstico , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 29(10): 1396-1402, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29894017

RESUMO

BACKGROUND: Implantable defibrillators (ICD) are an important therapy for arrhythmogenic right ventricular cardiomyopathy (ARVC) patients at high risk of sudden death. Given the high appropriate ICD therapy rate, some have argued that the mere act of implanting an ICD inflates the malignant arrhythmia rate in ARVC. OBJECTIVE: To report the arrhythmic course of ARVC patients without ICDs at the fulfillment of the 2010 Task Force Criteria and explore predictors of malignant ventricular arrhythmias. METHODS: We included 131 definite ARVC patients (age 32 ± 15 years, male 39%, proband 50%) either without ICDs (N  =  47) or receiving an ICD at least 6 months after the fulfillment of the diagnostic criteria. The primary outcome was a composite of cardiac arrest (both resuscitated successfully and unsuccessfully) and sustained ventricular tachyarrhythmias (cycle length< 600 milliseconds, at least 30 seconds or requiring an intervention for termination). RESULTS: At the fulfillment of the diagnostic criteria, ICDs were not recommended to 59 (45%) patients and declined by 22 (17%) patients. Forty (31%) patients were not recognized as having ARVC by the treating physicians. Over 8 (interquartile interval: 3-12) years, 38 (29%) patients had primary outcomes (8 cardiac arrests [3 died] and 30 sustained ventricular arrhythmias) while not having ICDs. The 1-year and 5-year event-free survival was 92% and 72%. Spontaneous sustained ventricular arrhythmias, cardiac syncope, men, proband, and inducibility in electrophysiology study were significantly associated with the primary outcome. CONCLUSION: In a contemporary cohort, a considerable risk of malignant arrhythmias existed in ARVC when ICDs were not implanted.


Assuntos
Arritmias Cardíacas/etiologia , Displasia Arritmogênica Ventricular Direita/complicações , Adulto , Arritmias Cardíacas/mortalidade , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/prevenção & controle , Displasia Arritmogênica Ventricular Direita/mortalidade , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Displasia Arritmogênica Ventricular Direita/terapia , Tomada de Decisão Clínica , Morte Súbita Cardíaca/etiologia , Desfibriladores Implantáveis , Progressão da Doença , Cardioversão Elétrica/instrumentação , Feminino , Parada Cardíaca/etiologia , Parada Cardíaca/mortalidade , Parada Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Intervalo Livre de Progressão , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Adulto Jovem
18.
Europace ; 20(4): e51-e59, 2018 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-28541507

RESUMO

Aims: Historical studies of ablation of atrioventricular nodal re-entrant tachycardia (AVNRT) have shown high long-term success rates and low complication rates. The potential impact of several recent practice trends has not been described. This study aims to characterize recent clinical practice trends in AVNRT ablation and their associated success rates and complications. Methods and results: Patients undergoing initial ablation of AVNRT between 1 July 2005 and 30 June 2015 were included in this study. Patient demographics and procedural data were abstracted from procedure reports. Follow-up data, including AVNRT recurrence and complications, was evaluated through electronic medical record review. In total, 877 patients underwent catheter ablation for AVNRT. By the last recorded year, three-dimension (3D) electroanatomical mapping (EAM) was used in 36.2%, 43.2% included anaesthesia, and 23.1% utilized irrigated catheters. Long-term procedural success was 95.5%. The use of anaesthesia, 3D EAM, and irrigated ablation catheters were not associated with differences in success. The presence of an atrial 'echo' or 'AH' jump at the end of an acutely successful procedure was not associated with long-term recurrence (P = 0.18, P = 0.15, respectively). Complications, including AV block requiring a pacemaker (0.4%), were uncommon. Conclusion: In a large, contemporary cohort, catheter ablation for AVNRT remains highly successful with low complications rates. The increased use of anaesthesia as well as modern mapping and ablation tools were not associated with changes in clinical outcomes. Further prospective evaluation of such contemporary practices is warranted given the lack of evidence to support their escalating use.


Assuntos
Ablação por Cateter , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Anestesia/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/tendências , Técnicas Eletrofisiológicas Cardíacas , Humanos , Complicações Pós-Operatórias/etiologia , Padrões de Prática Médica/tendências , Recidiva , Estudos Retrospectivos , Fatores de Risco , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico , Taquicardia por Reentrada no Nó Atrioventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento , Fluxo de Trabalho
19.
Pacing Clin Electrophysiol ; 41(4): 345-352, 2018 04.
Artigo em Inglês | MEDLINE | ID: mdl-29405366

RESUMO

AIMS: Prior studies identified a relationship between epicardial bipolar and endocardial unipolar voltage. Whether the relationship is valid with smaller multielectrode mapping catheters has not been reported. We explored the association of right ventricular (RV) endocardial unipolar voltage mapping with epicardial bipolar voltage mapping using a multielectrode mapping catheter. METHODS: Electrograms from patients who underwent multielectrode endocardial and epicardial RV electroanatomical mapping during ablation procedures were analyzed. Each endocardial mapping point was matched to the corresponding nearest epicardial point. The correlation between unipolar endocardial voltage and epicardial bipolar voltage was determined. The optimal unipolar threshold to detect epicardial low voltage (< 1.0 mV) and dense scar (0.5 mV) was calculated. RESULTS: A total of 4,895 points were analyzed. There was a significant correlation between endocardial unipolar and epicardial bipolar voltage (Spearman rho  =  0.499, P  =  < 0.001). The extent of the correlation was inversely associated with wall thickness. The receiver operator characteristic analysis of endocardial unipolar voltage predicting epicardial bipolar voltage of < 1.0 mV and < 0.5 showed an area under the curve of 0.769 and 0.812, respectively. The endocardial unipolar voltage that had the highest sensitivity and specificity in detecting epicardial bipolar voltage of < 1.0 mV and < 0.5 mV was 3.3 mV (70.3% sensitivity, 70.3% specificity), and 2.8 mV (sensitivity 73.8%, specificity 73.3%), respectively. CONCLUSION: Epicardial low voltage of the RV can be assessed by unipolar endocardial voltage using small multielectrode catheters. The strength of the association was inversely correlated with the wall thickness.


Assuntos
Ablação por Cateter , Cicatriz/fisiopatologia , Mapeamento Epicárdico/métodos , Ventrículos do Coração/fisiopatologia , Taquicardia Ventricular/fisiopatologia , Taquicardia Ventricular/cirurgia , Adulto , Mapeamento Epicárdico/instrumentação , Feminino , Sistema de Condução Cardíaco/fisiopatologia , Humanos , Masculino , Estudos Retrospectivos
20.
Pacing Clin Electrophysiol ; 41(12): 1611-1618, 2018 12.
Artigo em Inglês | MEDLINE | ID: mdl-30375674

RESUMO

BACKGROUND: Pacemaker patients experience battery depletion that activates pacemaker's alert for replacement notification. Automatic reprogramming at replacement notification can result in loss of rate response and atrioventricular (AV) synchrony. OBJECTIVE: To determine if relevant symptoms or clinical events may be associated with automatic reprogramming at replacement notification. METHODS: Electronic medical record review was undertaken for 298 patients referred for pacemaker generator replacement. Primary endpoints were symptoms or clinical events during replacement notification period. RESULTS: Following elimination of duplicate pacemaker replacements (n = 12), "near-replacement notification" or "recalled" (n = 15) and pacemakers at "end of life" (n = 5), 266 subjects were included. Three distinct reprogramming cohorts were identified; those with no change (control) in pacing mode (n = 46), those with loss of rate response (n = 154), and those with loss of AV synchrony ± rate response (n = 66). In total, 83 subjects (31.2%) had symptoms with significant differences seen between groups (control = 4.3%, loss of rate response = 26.0%, loss of AV synchrony ± rate response = 62.1%, P < 0.001). Overall, 28 subjects (10.5%) experienced clinical events with significant differences seen between groups (control = 0.0%, loss of rate response = 6.5%, loss of AV synchrony ± rate response = 27.3%, P < 0.001). CONCLUSIONS: Automatic reprogramming at replacement notification was associated with significant symptoms in 26% of those who lost rate response and in 62% of those who lost AV synchrony ± rate response. Additionally, 27% of the latter cohort required nonelective clinical care.


Assuntos
Fontes de Energia Elétrica , Marca-Passo Artificial , Idoso , Idoso de 80 Anos ou mais , Remoção de Dispositivo , Eletrodos Implantados , Falha de Equipamento , Análise de Falha de Equipamento , Feminino , Humanos , Masculino , Estudos Retrospectivos , Fatores de Tempo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA