Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 22
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Chem Phys ; 158(23)2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37341294

RESUMO

Intensities of 14 lines in the sixth overtone (7-0) band of carbon monoxide (12C16O) are measured in the visible range between 14 300 and 14 500 cm-1 using a frequency-stabilized cavity ring-down spectrometer. This is the first observation of such a high and weak overtone spectrum of the CO molecule. A theoretical model is constructed and tested based on the use of a high accuracy ab initio dipole moment curve and a semi-empirical potential energy curve. Accurate studies of high overtone transitions provide a challenge to both experiment and theory as the lines are very weak: below 2 × 10-29 cm molecule-1 at 296 K. Agreement between theory and experiment within the experimental uncertainty of a few percent is obtained. However, this agreement is only achieved after issues with the stability of the Davidson correction to the multi-reference configuration interaction calculations are addressed.

2.
Phys Rev Lett ; 129(4): 043002, 2022 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-35939021

RESUMO

Intensities of lines in the near-infrared second overtone band (3-0) of ^{12}C^{16}O are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1‰ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1‰ level. This set of highly accurate intensities can provide an intrinsic reference for reducing biases in future measurements of spectroscopic peak areas.


Assuntos
Espectroscopia de Infravermelho com Transformada de Fourier
3.
J Chem Phys ; 156(8): 084301, 2022 Feb 28.
Artigo em Inglês | MEDLINE | ID: mdl-35232214

RESUMO

We present the results of direct measurements of the line mixing parameters for two pairs of overlapping transitions at the band head of the oxygen B band. Measurements were performed with the frequency-stabilized cavity ring-down spectrometer assisted by an optical frequency comb. The recorded spectra were analyzed with line profiles comprising speed dependence, Dicke narrowing, and line mixing. Incorporation of the line mixing into the model eliminated previous discrepancies for pressure shift and their speed dependence coefficients. First-order line mixing was determined directly from the line shape fitting at relatively low pressure (0.04 atm) together with other line shape parameters and compared with that calculated by Sung et al. [J. Quant. Spectrosc. Radiat. Transfer 235, 232-243 (2019)].

4.
Opt Express ; 29(24): 39449-39460, 2021 Nov 22.
Artigo em Inglês | MEDLINE | ID: mdl-34809309

RESUMO

Frequency-based cavity mode-dispersion spectroscopy (CMDS), previously applied for Doppler-limited molecular spectroscopy, is now employed for the first time for saturation spectroscopy. Comparison with two intensity-based, cavity-enhanced absorption spectroscopy techniques, i.e. cavity mode-width spectroscopy (CMWS) and the well-established cavity ring-down spectroscopy (CRDS), shows the predominance of the CMDS. The method enables measurements in broader pressure range and shows high immunity of the Lamb dip position to the incomplete model of saturated cavity mode shape. Frequencies of transitions from the second overtone of CO are determined with standard uncertainty below 500 Hz which corresponds to relative uncertainty below 3 × 10-12. The pressure shift of the Lamb dips, which has not been detected for these transitions in available literature data, is observed.

5.
Opt Lett ; 45(7): 1603-1606, 2020 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-32235953

RESUMO

We report the most accurate, to the best of our knowledge, measurement of the position of the weak quadrupole S(2) 2-0 line in $ {{\rm D}_2} $D2. The spectra were collected with a frequency-stabilized cavity ringdown spectrometer (FS-CRDS) with an ultrahigh finesse optical cavity ($ {\cal F} = 637 000 $F=637000) and operating in the frequency-agile, rapid scanning spectroscopy (FARS) mode. Despite working in the Doppler-limited regime, we reached 40 kHz of statistical uncertainty and 161 kHz of absolute accuracy, achieving the highest accuracy for homonuclear isotopologues of molecular hydrogen. The accuracy of our measurement corresponds to the fifth significant digit of the leading term in quantum electrodynamics (QED) correction. We observe $ 2.3\sigma $2.3σ discrepancy with the recent theoretical value.

6.
Opt Express ; 27(8): 11069-11083, 2019 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-31052957

RESUMO

We report the measurement of the absolute frequencies of the 6s2 1S0-6s6p 3P1 transition (253.7 nm) and the relevant isotope shifts in five mercury isotopes  198Hg,  199Hg,  200Hg,  202Hg, and  204Hg. The Doppler-free saturated absorption measurements were performed in an atomic vapour cell at room temperature with a four-harmonic generated (FHG) continuous-wave (cw) laser digitally locked to the atomic transition. It was referenced with a femtosecond optical frequency comb synchronized to the frequency of local representation of the International Atomic Time to provide traceability to the SI second by the 330 km-long stabilized fibre optical link. The transition frequencies and isotope shifts have been determined with an accuracy of a few hundred kHz, at least one order of magnitude better than any previous measurement. By making a King plot with the isotope shifts of 6s6p 3P2-6s7s 3S1 transition (546 nm) we determined the accurate value of the ratio of the electronic field-shift parameters E546/E254 and estimated the electronic field-shift term E254.

7.
Opt Express ; 27(15): 21810-21821, 2019 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-31510251

RESUMO

A spectroscopic method free from systematic errors is desired for many challenging applications of gas detection. Although existing cavity-enhanced techniques exhibit very high precision, their accuracy strongly depends on propagation of the light amplitude through an optical system and its detection. Here, we demonstrate that the frequency-based molecular dispersion spectroscopy, involving sub-Hz-level precision in frequency measurements of optical cavity resonances, leads to sub-per-mille accuracy and a wide dynamic range, both previously unattainable by any other spectroscopic technique. The method offers great sensitivity of 5×10-11 cm-1, high speed, limited only by the fundamental response time of the cavity, and traceability of both axes of the spectrum to the primary frequency standard. All these features are necessary for convenient realization of comprehensive molecular spectroscopy from Doppler up to collisional regime without changing the spectroscopic method and modification of the experimental setup. Moreover, the presented approach does not require linear, high-bandwidth nor phase-sensitive detectors and can be directly implemented in existing cavity-enhanced spectrometers utilizing either continuous-wave or coherent broadband radiation. We experimentally prove the predominance of frequency-based spectroscopy over intensity-based one. Our results motivate replacement of intensity-based absorption spectroscopy with a pure frequency-based dispersion one in applications where the highest accuracy is required.

8.
Opt Express ; 26(5): 5644-5654, 2018 Mar 05.
Artigo em Inglês | MEDLINE | ID: mdl-29529766

RESUMO

The response of an optical cavity to incomplete extinction of nearly resonant incident light was experimentally examined. Measurements were performed using a Pound-Drever-Hall-locked frequency-stabilized cavity ring-down spectrometer (CRDS) that allowed the laser frequency detuning from the cavity resonance center to be controlled at Hz-level resolution. It is shown that an insufficient laser light extinction ratio combined with a phase shift and frequency detuning may lead to non-exponential cavity pumping and decay signals. The experimental results can be explained with a simple analytical model. The non-exponential decay can lead to a systematic shift as high as 0.5% in the ring-down time constants, dependent on the laser frequency detuning from the cavity mode center and on the extinction ratio. This can lead to appreciable systematic errors in the absorption coefficients determined with the CRDS technique.

9.
Opt Express ; 25(4): 3165-3179, 2017 Feb 20.
Artigo em Inglês | MEDLINE | ID: mdl-28241534

RESUMO

We present a two-species laser cooling apparatus capable of simultaneously collecting Rb and Hg atomic gases into a magneto-optical trap (MOT). The atomic sources, laser system, and vacuum set-up are described. While there is a loss of Rb atoms in the MOT due to photoionization by the Hg cooling laser, we show that it does not prevent simultaneous trapping of Rb and Hg. We also demonstrate interspecies collision-induced losses in the 87Rb-202Hg system.

10.
Opt Express ; 23(11): 14472-86, 2015 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-26072808

RESUMO

Recent developments in optical metrology have tremendously improved the precision and accuracy of the horizontal (frequency) axis in measured spectra. However, the vertical (typically absorbance) axis is usually based on intensity measurements that are subject to instrumental errors which limit the spectrum accuracy. Here we report a one-dimensional spectroscopy that uses only the measured frequencies of high-finesse cavity modes to provide complete information about the dispersive properties of the spectrum. Because this technique depends solely on the measurement of frequencies or their differences, it is insensitive to systematic errors in the detection of light intensity and has the potential to become the most accurate of all absorptive and dispersive spectroscopic methods. The experimental results are compared to measurements by two other high-precision cavity-enhanced spectroscopy methods. We expect that the proposed technique will have significant impact in fields such as fundamental physics, gas metrology and environmental remote sensing.

11.
J Chem Phys ; 141(17): 174301, 2014 Nov 07.
Artigo em Inglês | MEDLINE | ID: mdl-25381508

RESUMO

Frequency-stabilized cavity ring-down spectroscopy was used to study CO2 lineshapes in the (20013) ← (00001) band centered near 2.06 µm. Two rovibrational transitions were chosen for this study to measure non-Voigt collisional effects for air-broadened lines over the pressure range of 7 kPa-28 kPa. Lineshape analysis for both lines revealed evidence of simultaneous Dicke (collisional) narrowing and speed-dependent effects that would introduce biases exceeding 2% in the retrieved air-broadening parameters if not incorporated in the modeling of CO2 lineshapes. Additionally, correlations between velocity- and phase/state changing collisions greatly reduced the observed Dicke narrowing effect. As a result, it was concluded that the most appropriate line profile for modeling CO2 lineshapes near 2.06 µm was the correlated speed-dependent Nelkin-Ghatak profile, which includes all of the physical effects mentioned above and leads to a consistent set of line shape parameters that are linear with gas pressure.

12.
Spectrochim Acta A Mol Biomol Spectrosc ; 312: 124041, 2024 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-38368819

RESUMO

We present the results of the spectral line-shape study of the first measurement of the extremely weak (7-0) band of the 12C16O molecule. Measurements were done with a highly sensitive cavity ring-down spectrometer. Collisional narrowing, analyzed in terms of speed-dependent effects, was observed for the first time for transitions with line intensities below 2⋅10-29 cm/molecule at 296 K. We provide a full set of line-shape parameters of the speed-dependent and regular Voigt profile analysis for 14 transitions from P and R branches. Experimental verification of a strong vibrational dependence of the pressure shifting described by the Hartmann model (Hartmann, 2009) is extended up to the sixth overtone highly sensitive to the model parameter.

13.
Opt Express ; 21(24): 29744-54, 2013 Dec 02.
Artigo em Inglês | MEDLINE | ID: mdl-24514525

RESUMO

We explore a cavity-enhanced spectroscopic technique based on determination of the absorbtion coefficient from direct measurement of spectral width of the mode of the optical cavity filled with absorbing medium. This technique called here the cavity mode-width spectroscopy (CMWS) is complementary to the cavity ring-down spectroscopy (CRDS). While both these techniques use information on interaction time of the light with the cavity to determine absorption coefficient, the CMWS does not require to measure very fast signals at high absorption conditions. Instead the CMWS method require a very narrow line width laser with precise frequency control. As an example a spectral line shape of P7 Q6 O2 line from the B-band was measured with use of an ultra narrow laser system based on two phase-locked external cavity diode lasers (ECDL) having tunability of ± 20 GHz at wavelength range of 687 to 693 nm.


Assuntos
Lasers , Refratometria/instrumentação , Ressonância de Plasmônio de Superfície/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação
14.
Opt Lett ; 38(22): 4581-4, 2013 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-24322079

RESUMO

We report the absolute frequency measurements of rubidium 5S-7S two-photon transitions with a cw laser digitally locked to an atomic transition and referenced to an optical frequency comb. The narrow, two-photon transition, 5S-7S (760 nm), insensitive to first-order in a magnetic field, is a promising candidate for frequency reference. The performed tests yielded more accurate transition frequencies than previously reported.

15.
Spectrochim Acta A Mol Biomol Spectrosc ; 303: 123185, 2023 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-37544214

RESUMO

The air-broadened lines from the oxygen B band were measured for the first time in controlled laboratory conditions with a high signal-to-noise ratio using frequency-stabilized cavity ring-down spectroscopy (FS-CRDS) referenced to the optical frequency comb. Spectra measured at various pressures and temperatures were analyzed with an advanced line-shape model, considering the speed-dependence of collisional broadening and shift, and the effect of velocity-changing collisions. The temperature dependence of collisional broadening and shift is determined, whereas no significant temperature dependence of speed-dependent parameters and Dicke narrowing was observed. In addition, we have demonstrated that reasonable estimation of temperature dependence for pressure broadening is possible even from measurements done in single temperature where the speed dependence of pressure broadening was determined. New spectroscopic data improve the accuracy of the air-broadened oxygen B-band spectra description by an order of magnitude.

16.
Phys Rev Lett ; 108(17): 173002, 2012 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-22680859

RESUMO

We report the successful production of subradiant states of a two-atom system in a three-dimensional optical lattice starting from doubly occupied sites in a Mott insulator phase of a quantum gas of atomic ytterbium. We can selectively produce either a subradiant 1(g) state or a superradiant 0(u) state by choosing the excitation laser frequency. The inherent weak excitation rate for the subradiant 1(g) state is overcome by the increased atomic density due to the tight confinement in a three-dimensional optical lattice. Our experimental measurements of binding energies, linewidth, and Zeeman shift confirm the observation of subradiant levels of the 1(g) state of the Yb(2) molecule.

17.
Sci Rep ; 12(1): 2377, 2022 Feb 11.
Artigo em Inglês | MEDLINE | ID: mdl-35149716

RESUMO

Cavity ring-down spectroscopy is a ubiquitous optical method used to study light-matter interactions with high resolution, sensitivity and accuracy. However, it has never been performed with the multiplexing advantages of direct frequency comb spectroscopy without significantly compromising spectral resolution. We present dual-comb cavity ring-down spectroscopy (DC-CRDS) based on the parallel heterodyne detection of ring-down signals with a local oscillator comb to yield absorption and dispersion spectra. These spectra are obtained from widths and positions of cavity modes. We present two approaches which leverage the dynamic cavity response to coherently or randomly driven changes in the amplitude or frequency of the probe field. Both techniques yield accurate spectra of methane-an important greenhouse gas and breath biomarker. When combined with broadband frequency combs, the high sensitivity, spectral resolution and accuracy of our DC-CRDS technique shows promise for applications like studies of the structure and dynamics of large molecules, multispecies trace gas detection and isotopic composition.

18.
Sci Rep ; 10(1): 1628, 2020 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-31988388

RESUMO

An amendment to this paper has been published and can be accessed via a link at the top of the paper.

19.
Sci Rep ; 9(1): 14807, 2019 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-31616025

RESUMO

Several extensions to the Standard Model of particle physics, including light dark matter candidates and unification theories predict deviations from Newton's law of gravitation. For macroscopic distances, the inverse-square law of gravitation is well confirmed by astrophysical observations and laboratory experiments. At micrometer and shorter length scales, however, even the state-of-the-art constraints on deviations from gravitational interaction, whether provided by neutron scattering or precise measurements of forces between macroscopic bodies, are currently many orders of magnitude larger than gravity itself. Here we show that precision spectroscopy of weakly bound molecules can be used to constrain non-Newtonian interactions between atoms. A proof-of-principle demonstration using recent data from photoassociation spectroscopy of weakly bound Yb2 molecules yields constraints on these new interactions that are already close to state-of-the-art neutron scattering experiments. At the same time, with the development of the recently proposed optical molecular clocks, the neutron scattering constraints could be surpassed by at least two orders of magnitude.

20.
Rev Sci Instrum ; 86(10): 106110, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26521007

RESUMO

We report a simple, robust cavity ring-down spectroscopy system to reliably measure trace moisture in gases at parts-per-trillion (ppt) levels. The performance of the system was evaluated on the basis of experiments performed in a manner traceable to the International System of Units. The obtained result was in good agreement with the primary trace-moisture standard at 12 nmol/mol (12 ppb) in N2 in amount-of-substance fraction. Measurement capability of residual moisture in high-purity dry N2 at ∼130 pmol/mol (130 ppt) was demonstrated, and background noise of 5.3 × 10(-12) cm(-1) was attained, corresponding to a minimum detectable H2O of 5 pmol/mol (5 ppt).

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA