Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 119
Filtrar
1.
BJU Int ; 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38060339

RESUMO

OBJECTIVE: To assess the added value of concurrent systematic randomised ultrasonography-guided biopsy (SBx) to multiparametric magnetic resonance imaging (mpMRI)-targeted biopsy and the additional rate of overdiagnosis of clinically insignificant prostate cancer (ciPCa) by SBx in a large contemporary, real-world cohort. PATIENTS AND METHODS: A total of 1552 patients with positive mpMRI and consecutive mpMRI-targeted biopsy and SBx were enrolled. Added value and the rate of overdiagnosis by SBx was evaluated. PRIMARY OUTCOME: added value of SBx, defined as detection rate of clinically significant PCa (csPCa; International Society of Urological Pathology [ISUP] Grade ≥2) by SBx, while mpMRI-targeted biopsy was negative or showed ciPCa (ISUP Grade 1). SECONDARY OUTCOME: rate of overdiagnosis by SBx, defined as detection of ciPCa in patients with negative mpMRI-targeted biopsy and PSA level of <10 ng/mL. RESULTS: Detection rate of csPCa by mpMRI-targeted biopsy and/or SBx was 753/1552 (49%). Added value of SBx was 145/944 (15%). Rate of overdiagnosis by SBx was 146/656 (22%). Added value of SBx did not change when comparing patients with previous prostate biopsy and biopsy naïve patients. In multivariable analysis, a Prostate Imaging-Reporting and Data System (PI-RADS) 4 index lesion (odds ratio [OR] 3.19, 95% confidence interval [CI] 1.66-6.78; P = 0.001), a PI-RADS 5 index lesion (OR 2.89, 95% CI 1.39-6.46; P = 0.006) and age (OR 1.05, 95% CI 1.03-1.08; P < 0.001) were independently associated with added value of SBx. CONCLUSIONS: In our real-world analysis, we saw a significant impact on added value and added rate of overdiagnosis by SBx. Subgroup analysis showed no significant decrease of added value in any evaluated risk group. Therefore, we do not endorse omitting concurrent SBx to mpMRI-guided biopsy of the prostate.

2.
AJR Am J Roentgenol ; 220(5): 682-691, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36382914

RESUMO

BACKGROUND. Previously proposed modifications to LI-RADS criteria for contrast-enhanced ultrasound (CEUS) performed using perfluorobutane contrast agent yielded increased sensitivity for hepatocellular carcinoma (HCC) without a significant decrease in specificity. OBJECTIVE. The purpose of our study was to compare the diagnostic performance of CEUS with perfluorobutane using modified LI-RADS criteria versus contrast-enhanced CT or MRI using LI-RADS version 2018 (v2018) for characterizing lesions as HCC in high-risk patients. METHODS. This retrospective study included 171 patients (140 men, 31 women; mean age, 54 ± 12 [SD] years) at high-risk for HCC with a pathologically confirmed liver observation evaluated by both CEUS using perfluorobutane and contrast-enhanced CT or MRI between March 2020 and May 2021. A matching algorithm was used to select two patients with HCC for each patient with a non-HCC lesion. Two readers evaluated observations using previously proposed modifications to CEUS LI-RADS version 2017 that classify certain observations as LR-5 rather than as LR-4 or LR-M on the basis of the presence of Kupffer phase defect after perfluorobutane administration; two different readers evaluated observations using CT/MRI LI-RADS v2018. Each reader pair reached consensus. Diagnostic performance was evaluated. RESULTS. A total of 114 patients had HCC, 43 had a non-HCC malignancy, and 14 had a benign lesion. Modified CEUS criteria using perfluorobutane and CT/MRI LI-RADS v2018 showed no significant difference (p > .05) in sensitivity (92.1% vs 89.5%), specificity (87.7% vs 84.2%), or accuracy (90.6% vs 87.7%) of LR-5 for diagnosis of HCC. Of six observations assessed as LR-4 only by CT/MRI LI-RADS v2018, modified CEUS criteria using perfluorobutane assessed one as LR-3 (benign lesion) and five as LR-5 (all HCC). Of seven observations assessed as LR-M only by CT/MRI LI-RADS v2018, modified CEUS criteria using perfluorobutane assessed one as LR-3 (non-HCC malignancy) and six as LR-5 (all HCC). Eight of 12 observations assessed as LR-5 only by CT/MRI LI-RADS v2018 and 11 of 13 observations assessed as LR-5 only by modified CEUS criteria using perfluorobutane were HCC. CONCLUSION. The diagnostic performance of LR-5 for HCC diagnosis was not significantly different between modified CEUS criteria using perfluorobutane and CT/MRI LI-RADS v2018. CLINICAL IMPACT. The findings support the application of modified CEUS criteria using perfluorobutane for diagnosing HCC in high-risk patients.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Masculino , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Idoso , Carcinoma Hepatocelular/diagnóstico por imagem , Carcinoma Hepatocelular/patologia , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/patologia , Estudos Retrospectivos , Meios de Contraste , Reprodutibilidade dos Testes , Imageamento por Ressonância Magnética/métodos , Tomografia Computadorizada por Raios X , Sensibilidade e Especificidade
3.
J Ultrasound Med ; 42(1): 247-253, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35579375

RESUMO

Hemoperitoneum in cirrhosis is a life-threatening condition that requires emergent evaluation. Contrast-enhanced ultrasound (CEUS) permits multiple dynamic characterizations of abdominal structures through all vascular phases, and contrast extravasation or the presence of microbubbles in the ascites could be a sensitive tool. We reviewed 13 patients with cirrhosis that underwent CEUS due to high suspicion for intra-abdominal bleeding. In 10 cases, CEUS demonstrated extravasation of contrast, including 2 instances where CEUS detected active bleeding despite negative computed tomography. These data support further study of CEUS in direct comparison to other imaging modalities in this clinical context.


Assuntos
Meios de Contraste , Hemoperitônio , Humanos , Cirrose Hepática , Ultrassonografia , Extravasamento de Materiais Terapêuticos e Diagnósticos
4.
J Ultrasound Med ; 42(8): 1729-1736, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36789976

RESUMO

OBJECTIVES: We evaluated whether lesion-to-fat ratio measured by shear wave elastography in patients with Breast Imaging Reporting and Data System (BI-RADS) 3 or 4 lesions has the potential to further refine the assessment of B-mode ultrasound alone in breast cancer diagnostics. METHODS: This was a secondary analysis of an international diagnostic multicenter trial (NCT02638935). Data from 1288 women with breast lesions categorized as BI-RADS 3 and 4a-c by conventional B-mode ultrasound were analyzed, whereby the focus was placed on differentiating lesions categorized as BI-RADS 3 and BI-RADS 4a. All women underwent shear wave elastography and histopathologic evaluation functioning as reference standard. Reduction of benign biopsies as well as the number of missed malignancies after reclassification using lesion-to-fat ratio measured by shear wave elastography were evaluated. RESULTS: Breast cancer was diagnosed in 368 (28.6%) of 1288 lesions. The assessment with conventional B-mode ultrasound resulted in 53.8% (495 of 1288) pathologically benign lesions categorized as BI-RADS 4 and therefore false positives as well as in 1.39% (6 of 431) undetected malignancies categorized as BI-RADS 3. Additional lesion-to-fat ratio in BI-RADS 4a lesions with a cutoff value of 1.85 resulted in 30.11% biopsies of benign lesions which correspond to a reduction of 44.04% of false positives. CONCLUSIONS: Adding lesion-to-fat ratio measured by shear wave elastography to conventional B-mode ultrasound in BI-RADS 4a breast lesions could help reduce the number of benign biopsies by 44.04%. At the same time, however, 1.98% of malignancies were missed, which would still be in line with American College of Radiology BI-RADS 3 definition of <2% of undetected malignancies.


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Humanos , Feminino , Sensibilidade e Especificidade , Técnicas de Imagem por Elasticidade/métodos , Ultrassonografia Mamária/métodos , Reprodutibilidade dos Testes , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Biópsia , Elasticidade , Diagnóstico Diferencial
5.
Ultraschall Med ; 44(5): 537-543, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36854384

RESUMO

PURPOSE: The aim of the study was to evaluate whether the quantification of B-lines via lung ultrasound after lung transplantation is feasible and correlates with the diagnosis of primary graft dysfunction. METHODS: Following lung transplantation, patients underwent daily lung ultrasound on postoperative days 1-3. B-lines were quantified by an ultrasound score based on the number of single and confluent B-lines per intercostal space, using a four-region protocol. The ultrasound score was correlated with the diagnosis of primary graft dysfunction. Furthermore, correlation analyses and receiver operating characteristics analyses taking into account ultrasound score, chest radiographs, and PaO2/FiO2 ratio were performed. RESULTS: A total of 32 patients (91 ultrasound measurements) were included, whereby 10 were diagnosed with primary graft dysfunction. The median B-line score was 5 [IQR: 4, 8]. There was a significant correlation between B-line score and the diagnosis of primary graft dysfunction (r = 0.59, p < 0.001). A significant correlation could also be seen between chest X-rays and primary graft dysfunction (r = 0.34, p = 0.008), but the B-line score showed superiority over chest X-rays with respect to diagnosing primary graft dysfunction in the receiver operating characteristics curves with an area under the curve value of 0.921 versus 0.708. There was a significant negative correlation between B-line score and PaO2/FiO2 ratio (r = -0.41, p < 0.001), but not between chest X-rays and PaO2/FiO2 ratio (r = -0.14, p = 0.279). CONCLUSION: The appearance of B-lines correlated well with primary graft dysfunction and outperformed chest radiographs.


Assuntos
Transplante de Pulmão , Disfunção Primária do Enxerto , Síndrome do Desconforto Respiratório , Humanos , Disfunção Primária do Enxerto/diagnóstico por imagem , Pulmão/diagnóstico por imagem , Ultrassonografia , Transplante de Pulmão/efeitos adversos
6.
Ultraschall Med ; 44(2): 162-168, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34425600

RESUMO

PURPOSE: In this prospective, multicenter trial we evaluated whether additional shear wave elastography (SWE) for patients with BI-RADS 3 or 4 lesions on breast ultrasound could further refine the assessment with B-mode breast ultrasound for breast cancer diagnosis. MATERIALS AND METHODS: We analyzed prospective, multicenter, international data from 1288 women with breast lesions rated by conventional 2 D B-mode ultrasound as BI-RADS 3 to 4c and undergoing 2D-SWE. After reclassification with SWE the proportion of undetected malignancies should be < 2 %. All patients underwent histopathologic evaluation (reference standard). RESULTS: Histopathologic evaluation showed malignancy in 368 of 1288 lesions (28.6 %). The assessment with B-mode breast ultrasound resulted in 1.39 % (6 of 431) undetected malignancies (malignant lesions in BI-RADS 3) and 53.80 % (495 of 920) unnecessary biopsies (biopsies in benign lesions). Re-classifying BI-RADS 4a patients with a SWE cutoff of 2.55 m/s resulted in 1.98 % (11 of 556) undetected malignancies and a reduction of 24.24 % (375 vs. 495) of unnecessary biopsies. CONCLUSION: A SWE value below 2.55 m/s for BI-RADS 4a lesions could be used to downstage these lesions to follow-up, and therefore reduce the number of unnecessary biopsies by 24.24 %. However, this would come at the expense of some additionally missed cancers compared to B-mode breast ultrasound (rate of undetected malignancies 1.98 %, 11 of 556, versus 1.39 %, 6 of 431) which would, however, still be in line with the ACR BI-RADS 3 definition (< 2 % of undetected malignancies).


Assuntos
Neoplasias da Mama , Técnicas de Imagem por Elasticidade , Feminino , Humanos , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Técnicas de Imagem por Elasticidade/métodos , Estudos Prospectivos , Sensibilidade e Especificidade , Diagnóstico Diferencial , Reprodutibilidade dos Testes , Ultrassonografia Mamária/métodos , Biópsia
7.
Eur Radiol ; 32(6): 4101-4115, 2022 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-35175381

RESUMO

OBJECTIVES: AI-based algorithms for medical image analysis showed comparable performance to human image readers. However, in practice, diagnoses are made using multiple imaging modalities alongside other data sources. We determined the importance of this multi-modal information and compared the diagnostic performance of routine breast cancer diagnosis to breast ultrasound interpretations by humans or AI-based algorithms. METHODS: Patients were recruited as part of a multicenter trial (NCT02638935). The trial enrolled 1288 women undergoing routine breast cancer diagnosis (multi-modal imaging, demographic, and clinical information). Three physicians specialized in ultrasound diagnosis performed a second read of all ultrasound images. We used data from 11 of 12 study sites to develop two machine learning (ML) algorithms using unimodal information (ultrasound features generated by the ultrasound experts) to classify breast masses which were validated on the remaining study site. The same ML algorithms were subsequently developed and validated on multi-modal information (clinical and demographic information plus ultrasound features). We assessed performance using area under the curve (AUC). RESULTS: Of 1288 breast masses, 368 (28.6%) were histopathologically malignant. In the external validation set (n = 373), the performance of the two unimodal ultrasound ML algorithms (AUC 0.83 and 0.82) was commensurate with performance of the human ultrasound experts (AUC 0.82 to 0.84; p for all comparisons > 0.05). The multi-modal ultrasound ML algorithms performed significantly better (AUC 0.90 and 0.89) but were statistically inferior to routine breast cancer diagnosis (AUC 0.95, p for all comparisons ≤ 0.05). CONCLUSIONS: The performance of humans and AI-based algorithms improves with multi-modal information. KEY POINTS: • The performance of humans and AI-based algorithms improves with multi-modal information. • Multimodal AI-based algorithms do not necessarily outperform expert humans. • Unimodal AI-based algorithms do not represent optimal performance to classify breast masses.


Assuntos
Inteligência Artificial , Neoplasias da Mama , Algoritmos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Feminino , Humanos , Imagem Multimodal
8.
Z Gastroenterol ; 60(2): 180-183, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35042269

RESUMO

A 95-year-old woman with metastasizing bronchial carcinoma presents with left inguinal pain. The referring physician would like to exclude an inguinal hernia and a deep vein thrombosis due to her precondition of essential thrombocythemia. Conventional ultrasound excluded the presence of a deep vein thrombosis yet showed a 6 cm × 5 cm hematoma distal of the left m. rectus abdominis. The subsequently performed color Doppler examination excluded a pseudoaneurysm but could not preclude active bleeding. Eventually, CEUS showed contrast-pooling within the hematoma as a sign of active extravasation, suggesting ongoing bleeding.


Assuntos
Meios de Contraste , Hematoma , Idoso de 80 Anos ou mais , Feminino , Hemorragia Gastrointestinal , Hematoma/induzido quimicamente , Hematoma/diagnóstico por imagem , Humanos , Injeções Subcutâneas , Ultrassonografia
9.
J Vasc Surg ; 73(1): 232-239.e2, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32442612

RESUMO

OBJECTIVE: Follow-up after endovascular aneurysm repair is necessary to detect potentially life-threatening complications such as endoleaks. Computed tomography angiography (CTA) or magnetic resonance angiography (MRA) is often used as standard of care for follow-up. Contrast-enhanced ultrasound (CEUS) has been shown to be a viable and fast real-time nonionizing imaging modality with equivalent diagnostic accuracy while also being superior to color Doppler ultrasound. The aim of this cost-utility analysis was to evaluate the cost-effectiveness of this imaging method in comparison to others for the evaluation of endoleaks requiring treatment. METHODS: A decision model based on Markov simulations estimated lifetime costs and quality-adjusted life years (QALYs) associated with CTA, MRA, CEUS, and color Doppler ultrasound. Model input parameters were obtained from recent literature. The applied sensitivity and specificity values amounted to 90.5% and 100.0% for CTA, 96.0% and 100.0% for MRA, 94.0% and 95.0% for CEUS, and 82.0% and 93.0% for color Doppler ultrasound. Probabilistic and deterministic sensitivity analysis was performed to estimate uncertainty of model results. To evaluate cost-effectiveness, incremental cost-effectiveness ratios were reported as a measure representing the economic value of a strategy compared with an alternative. The willingness to pay was set to $100,000/QALY. RESULTS: In the base-case scenario for a willingness to pay of $100,000 per QALY, CEUS was the most cost-effective of the four diagnostic strategies with estimated costs of $17,383 and effectiveness of 9.770 QALYs. CTA was estimated to result in lifetime costs of $17,679 with an expected effectiveness of 9.768 QALYs, whereas color Doppler ultrasound showed expected costs of $17,287 with 9.763 QALYs. Expected costs and effectiveness of MRA amounted to $17,945 and 9.771 QALYs each. Base-case estimates of the incremental cost-effectiveness ratios for CEUS vs color Doppler ultrasound equaled $14,173.52/QALY. CONCLUSIONS: CEUS is a cost-effective imaging method for the evaluation of therapy-requiring endoleaks in endovascular aneurysm repair surveillance.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Endoleak/diagnóstico , Procedimentos Endovasculares/efeitos adversos , Ultrassonografia Doppler em Cores/economia , Adulto , Idoso , Idoso de 80 Anos ou mais , Angiografia por Tomografia Computadorizada/economia , Análise Custo-Benefício , Endoleak/economia , Endoleak/terapia , Feminino , Humanos , Angiografia por Ressonância Magnética/economia , Masculino , Pessoa de Meia-Idade , Reoperação/economia
10.
Urol Int ; 105(5-6): 520-524, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33535217

RESUMO

INTRODUCTION: Prostate cancer (PCa) is the most common malignancy in men. The multiparametric MRI (mpMRI) significantly improved the diagnostic approach of PCa. Although PCa is highly likely to be present in prostate imaging-reporting and data system (PI-RADS) 5 lesions, there are up to 18% of PI-RADS 5 lesions with benign histopathology after targeted biopsy. CASE DESCRIPTION: We present the case of a 66-year-old man who was referred to our hospital for MRI/ultrasound fusion-based targeted biopsy due to an elevated PSA and a PI-RADS 5 lesion described in the mpMRI. After 2 consecutive biopsies, the mpMRI target showed no malignancy. The lesion was described as PI-RADS 2 two years later. CONCLUSION: This case demonstrates the risk of false-positive classified PI-RADS 5 lesions in the mpMRI and the challenge in some cases to distinguish between BPH nodules and cancer. Until today, a limited amount of studies exists concerning this issue. However, further studies are required to evaluate further characteristics associated with a higher possibility of histopathologically benign findings in PI-RADS 5 lesions.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Sistemas de Dados , Humanos , Masculino , Neoplasias da Próstata/classificação , Projetos de Pesquisa
11.
Arch Gynecol Obstet ; 303(1): 103-112, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32761368

RESUMO

PURPOSE: Conventional ultrasound is the main imaging modality in obstetrics for assessing the maternal and fetal status. Up to date, contrast-enhanced ultrasound (CEUS) has not found widespread use in gynecology and obstetrics, but recent studies demonstrate promising results. The aim of the present study is to assess safe and valuable application of CEUS during pregnancy to investigate non-obstetric conditions. METHODS: Five pregnant patients on whom CEUS was performed between 2019 and 2020 were included in this retrospective single-center study. A total of six CEUS examinations were performed including one CEUS-guided biopsy (mean age: 31 years, mean weeks of pregnancy: 18 weeks). CEUS examinations were performed by a consultant radiologist (EFSUMB level 3). RESULTS: All included pregnant women safely underwent CEUS. Neither maternal nor fetal adverse effects were detected. CEUS critically helped in the diagnostic workup of a desmoid tumor of the abdominal wall, hepatic hemangioma, amebic hepatic abscess, uncomplicated renal cyst and post-inflammatory alteration of the renal cortex and for excluding active abdominal bleeding. In addition, CEUS-guided biopsy was performed to prevent intratumoral hemorrhage. Findings from CEUS prompted immediate treatment in two women, whereas in three women regular obstetric monitoring of the women could be conducted. CONCLUSION: Our results demonstrate safe and crucial application of off-label CEUS in pregnant women to assess different non-obstetric conditions allowing to prevent additional ionizing CT or application of (gadolinium-based) contrast agent in MRI. Hence, CEUS might add pivotal value for evaluating obstetric and non-obstetric conditions and thereby directing clinical management of pregnant women in the future.


Assuntos
Meios de Contraste/administração & dosagem , Hemangioma/diagnóstico por imagem , Abscesso Hepático Amebiano/diagnóstico por imagem , Ultrassonografia Doppler em Cores/métodos , Ultrassonografia/métodos , Adulto , Meios de Contraste/uso terapêutico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Gravidez , Estudos Retrospectivos , Ultrassonografia Doppler em Cores/efeitos adversos
12.
Ultraschall Med ; 42(4): 348-366, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-33915577

RESUMO

In recent years, the implementation of contrast-enhanced ultrasound (CEUS) in clinical practice has opened new horizons in the arterial pathologies research field, since this technique is able to supply new sets of data that can be crucial in patient management. The main applications of CEUS in the arterial system are the detection, characterization, and follow-up of carotid plaques and endoleaks after EVAR. Other situations in which CEUS was demonstrated to be a useful tool are large vessel vasculitis, dissections, and untreated aneurysms. In carotid atherosclerosis CEUS is not only able to acquire quantitative data about stenosis but also to perform a qualitative assessment of the plaque. The most important plaque features that CEUS is able to depict are ulceration, neovascularization, and the presence of inflammatory infiltrates. All of these factors contribute to plaque vulnerability. Thus, CEUS is crucial in order to allow better risk stratification and management of patients. In follow-up after EVAR, CEUS shows sensitivity and specificity values similar to CTA while ensuring several advantages, such as lower cost and the absence of ionizing radiation and nephrotoxic agents. Moreover, CEUS is able to offer real-time evaluation of endoleaks and thus is a useful tool in cases that are ambiguous on CTA. Most limitations are patient-related and are the same as in all other ultrasound techniques, such as high BMI and meteorism.


Assuntos
Aneurisma da Aorta Abdominal , Meios de Contraste , Endoleak , Humanos , Sensibilidade e Especificidade , Ultrassonografia
13.
Ultraschall Med ; 42(3): 306-313, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32102105

RESUMO

PURPOSE: Fibrolamellar hepatocellular carcinoma (f-HCC) is a rare primary liver tumor. Imaging plays an important role in diagnosis. The aim of this retrospective study was to analyze contrast-enhanced ultrasound (CEUS) features of histologically proven f-HCC in comparison to benign focal nodular hyperplasia (FNH). MATERIALS & METHODS: 16 patients with histologically proven f-HCC lesions and 30 patients with FNH lesions were retrospectively reviewed regarding CEUS features to determine the malignant or benign nature of the focal liver lesions (FLL). Five radiologists assessed the CEUS enhancement pattern and came to a consensus using the EFSUMB (European Federation of Societies for Ultrasound in Medicine and Biology) guideline criteria. RESULTS: Fibrolamellar hepatocellular carcinoma manifested as a single and huge FLL. On CEUS, f-HCC showed heterogeneous hyperenhancement in the arterial phase and hypoenhancement (16/16, 100 %) in the portal venous and late phases (PVLP) as a sign of malignancy. In contrast to the hypoenhancement of f-HCC in the PVLP, all patients with FNH showed hyperenhancement as the most distinctive feature (P < 0.01). 8 f-HCC lesions showed a central scar as an unenhanced area (8/16, 50.0 %), which could also be detected in 53.3 % (16/30) of FNH lesions (P > 0.05). CONCLUSION: By analyzing the hypoenhancement in the PVLP, CEUS imaging reliably diagnosed f-HCC as a malignant FLL. CEUS also showed differentiation between f-HCC and FNH lesions, showing similar non-enhanced central scars, whereas f-HCC lesions showed peripheral hyperenhancement in the arterial phase and early washout in the PVLP.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Carcinoma Hepatocelular/diagnóstico por imagem , Meios de Contraste , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia
14.
Ultraschall Med ; 42(4): 411-417, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32052386

RESUMO

PURPOSE: Correct differentiation between malignant and benign incidentally found cystic renal lesions has critical implications for patient management. In several studies contrast-enhanced ultrasound (CEUS) showed higher sensitivity with respect to the accurate characterization of these lesions compared to MRI, but the cost-effectiveness of CEUS has yet to be investigated. The aim of this study was to analyze the cost-effectiveness of CEUS as an alternative imaging method to MRI for the characterization of incidentally found cystic renal lesions. MATERIALS AND METHODS: A decision model including the diagnostic modalities MRI and CEUS was created based on Markov simulations estimating lifetime costs and quality-adjusted life years (QALYs). The recent literature was reviewed to obtain model input parameters. The deterministic sensitivity of diagnostic parameters and costs was determined and probabilistic sensitivity analysis using Monte-Carlo Modelling was applied. Willingness-to-pay (WTP) was assumed to be $ 100 000/QALY. RESULTS: In the base-case scenario, the total costs for CEUS were $9654.43, whereas the total costs for MRI were $9675.03. CEUS resulted in an expected effectiveness of 8.06 QALYs versus 8.06 QALYs for MRI. Therefore, from an economic point of view, CEUS was identified as an adequate diagnostic alternative to MRI. Sensitivity analysis showed that results may vary if CEUS costs increase or those of MRI decrease. CONCLUSION: Based on the results of the analysis, the use of CEUS was identified as a cost-effective diagnostic strategy for the characterization of incidentally found cystic renal lesions.


Assuntos
Neoplasias Renais , Imageamento por Ressonância Magnética , Meios de Contraste , Análise Custo-Benefício , Humanos , Rim/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Ultrassonografia
15.
Ultraschall Med ; 42(2): 154-166, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33307594

RESUMO

The well-established Bosniak renal cyst classification is based on contrast-enhanced computed tomography determining the malignant potential of cystic renal lesions. Ultrasound has not been incorporated into this pathway. However, the development of ultrasound contrast agents coupled with the superior resolution of ultrasound makes it possible to redefine the imaging of cystic renal lesions. In this position statement, an EFSUMB Expert Task Force reviews, analyzes, and describes the accumulated knowledge and limitations and presents the current position on the use of ultrasound contrast agents in the evaluation of cystic renal lesions.


Assuntos
Cistos , Doenças Renais Císticas , Neoplasias Renais , Meios de Contraste , Cistos/diagnóstico por imagem , Humanos , Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia
16.
Medicina (Kaunas) ; 57(1)2021 Jan 09.
Artigo em Inglês | MEDLINE | ID: mdl-33435420

RESUMO

Background and Objectives: Vesicoureteral reflux (VUR) describes a common pediatric anomaly in pediatric urology with a prevalence of 1-2%. In diagnostics, in addition to the gold standard of voiding cystourethrography (VCUG), contrast-enhanced urosonography (ceVUS) offers a radiation-free procedure, which, despite its advantages, is not yet widely used. In the present single-center study, subsequent therapeutic procedures and outcomes after ceVUS of 49 patients were investigated. The aim of the study is to investigate the efficacy of ceVUS with the intention of broader clinical implementation. Materials and Methods: Between 2016 and 2020, 49 patients were retrospectively included and received a ceVUS to evaluate VUR. With a distribution of 47:2 (95.9%), a clear female predominance was present. The age of the patients varied between 5 months and 60 years at the time of ceVUS. All examinations were all performed and subsequently interpreted by a single experienced radiologist (EFSUMB level 3). Results: Compared to intraoperative findings, ceVUS shows a sensitivity of 95.7% with a specificity of 100%. Allergic reactions to the contrast medium could not be observed. Conclusion: With its high sensitivity and intraoperative validation, ceVUS offers an excellent alternative to VCUG, the gold standard in the diagnosis of VUR. In addition, ceVUS is a radiation-free examination method with a low risk profile that offers an exceptional diagnostic tool in the diagnostic clarification of recurrent urinary tract infections with the suspected diagnosis of VUR and should also be included in the consideration of a diagnosis next to the established VCUG, especially in younger children.


Assuntos
Meios de Contraste , Técnicas de Diagnóstico Urológico , Ultrassonografia/métodos , Refluxo Vesicoureteral/diagnóstico por imagem , Adolescente , Adulto , Antibacterianos/uso terapêutico , Criança , Pré-Escolar , Cistografia , Feminino , Humanos , Lactente , Injeções , Laparoscopia , Masculino , Pessoa de Meia-Idade , Fosfolipídeos , Politetrafluoretileno , Exposição à Radiação , Recidiva , Sensibilidade e Especificidade , Índice de Gravidade de Doença , Hexafluoreto de Enxofre , Ureteroscopia , Uretra/diagnóstico por imagem , Bexiga Urinária/diagnóstico por imagem , Infecções Urinárias/etiologia , Infecções Urinárias/prevenção & controle , Urografia , Refluxo Vesicoureteral/classificação , Refluxo Vesicoureteral/complicações , Refluxo Vesicoureteral/terapia , Adulto Jovem
17.
J Ultrasound Med ; 39(6): 1047-1056, 2020 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-31840876

RESUMO

The scrotum may be affected by a plethora of different disorders such as infections, vasculopathies, trauma, and manifestations of primary and secondary malignant masses. In addition to the patient's medical history and clinical examination, ultrasound represents the imaging modality of choice to assess scrotal disorders. Time-consuming contrast-enhanced ultrasound and elastography can provide further information to distinguish between benign and malignant testicular mass lesions. The following invited Special Communication gives a comprehensive overview of differential diagnoses of the scrotum and their corresponding sonomorphologic correlates based on representative cases of the Interdisciplinary Ultrasound Center of the University Hospital Munich.


Assuntos
Escroto/diagnóstico por imagem , Escroto/patologia , Doenças Testiculares/diagnóstico por imagem , Doenças Testiculares/patologia , Ultrassonografia/métodos , Diagnóstico Diferencial , Humanos , Masculino
18.
Ultraschall Med ; 41(1): 29-35, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31362328

RESUMO

BACKGROUND: Ultrasound is an essential imaging tool for evaluating physiological and pathological fetal or maternal conditions during pregnancy. Published data is limited with respect to the application of CEUS during pregnancy. CEUS has already been safely applied for assessing uteroplacental blood flow, cesarean scar pregnancy and invasive placenta percreta. CT and MRI scans during pregnancy must be thoroughly evaluated due to harmful ionizing radiation and cerebral gadolinium deposition, respectively. PURPOSE: The aim of the present retrospective single-center study is to assess the diagnostic performance and safety of CEUS during pregnancy to evaluate hepatic lesions of unknown entity. METHODS: 6 pregnant patients who underwent CEUS between 2005 and 2014 (mean age: 32 years; mean weeks of pregnancy: 28 weeks) were included in this study. The applied contrast agent was a second-generation blood-pool agent (SonoVue®, Bracco, Milan, Italy). CEUS examinations were performed and interpreted by a single radiologist with experience since 2000 (EFSUMB Level 3). RESULTS: CEUS was safely performed on all included pregnant women without the occurrence of adverse fetal or maternal events. In the context of the present study, CEUS helped to safely differentiate hepatic metastases, focal nodular hyperplasia, atypical hemangioma, hepatic arteriovenous malformation and cystic echinococcosis. In two patients CEUS determined immediate therapy. CONCLUSION: Although not clinically approved in obstetrics so far, CEUS is a safe imaging modality which, in addition to B-mode and color Doppler ultrasonography, may be applied during pregnancy for further medical indications and to provide helpful information.


Assuntos
Meios de Contraste , Neoplasias Hepáticas , Complicações Neoplásicas na Gravidez , Ultrassonografia Doppler em Cores , Adulto , Feminino , Humanos , Neoplasias Hepáticas/diagnóstico por imagem , Neoplasias Hepáticas/secundário , Gravidez , Complicações Neoplásicas na Gravidez/diagnóstico por imagem , Estudos Retrospectivos , Ultrassonografia Doppler em Cores/efeitos adversos
19.
Ultraschall Med ; 41(6): 668-674, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31597180

RESUMO

PURPOSE: Accurate characterization of testicular lesions is crucial to allow for correct treatment of malignant tumors and to avoid unnecessary procedures in benign ones. In recent years, contrast-enhanced ultrasound (CEUS) proved to be superior in specifying the dignity of small, nonpalpable testicular lesions (< 1.5 cm) compared to native B-mode and color Doppler ultrasound which were previously regarded as the primary imaging method. However, the cost-effectiveness of CEUS has not been evaluated yet. The aim of this study was to analyze the cost-effectiveness of CEUS as compared to unenhanced ultrasound for the characterization of nonpalpable testicular lesions. METHODS: A decision model based on Markov simulations estimated lifetime costs and quality-adjusted life years (QALYs) associated with unenhanced ultrasound and CEUS. Model input parameters were obtained from recent literature. Deterministic sensitivity analysis of diagnostic parameters and costs was performed. Also, probabilistic sensitivity analysis using Monte-Carlo Modelling was applied. The willingness-to-pay (WTP) was set to $100 000/QALY. RESULTS: In the base-case scenario, unenhanced ultrasound resulted in total costs of $5113.14 and an expected effectiveness of 8.29 QALYs, whereas CEUS resulted in total costs of $4397.77 with 8.35 QALYs. Therefore, the unenhanced ultrasound strategy was dominated by CEUS in the base-case scenario. Sensitivity analysis showed CEUS to be the cost-effective alternative along a broad range of costs. CONCLUSION: Contrast-enhanced ultrasound is a cost-effective imaging method for the characterization of nonpalpable testicular lesions.


Assuntos
Neoplasias Testiculares , Ultrassonografia Doppler em Cores , Análise Custo-Benefício , Humanos , Masculino , Anos de Vida Ajustados por Qualidade de Vida , Neoplasias Testiculares/diagnóstico por imagem , Ultrassonografia , Ultrassonografia Doppler em Cores/economia
20.
Ultraschall Med ; 41(5): 562-585, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32707595

RESUMO

The present, updated document describes the fourth iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS), first initiated in 2004 by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB). The previous updated editions of the guidelines reflected changes in the available contrast agents and updated the guidelines not only for hepatic but also for non-hepatic applications.The 2012 guideline requires updating as previously the differences of the contrast agents were not precisely described and the differences in contrast phases as well as handling were not clearly indicated. In addition, more evidence has been published for all contrast agents. The update also reflects the most recent developments in contrast agents, including the United States Food and Drug Administration (FDA) approval as well as the extensive Asian experience, to produce a truly international perspective.These guidelines and recommendations provide general advice on the use of ultrasound contrast agents (UCA) and are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis to improve the management of patients.


Assuntos
Meios de Contraste , Ultrassonografia , Meios de Contraste/normas , Humanos , Ultrassonografia/normas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA