Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Radiol Med ; 126(8): 1085-1094, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34008045

RESUMO

This study evaluated the ability of T2 mapping magnetic resonance imaging at 3 T, in addition to morphological sequences, to assess efficacy of platelet-rich plasma (PRP) injections, characterizing qualitatively and quantitatively the grade of knee cartilage repair in patients with patellofemoral chondropathy. We retrospectively studied 34 patients (22 men, 12 women, mean age 41.8 years, including 22 men) with patellofemoral knee chondropathy, who underwent intra-articular PRP injections and completed a clinical and instrumental follow-up. As control group, we evaluated 34 patients who underwent non-operative therapy. All patients were submitted to clinical (using VAS and WOMAC index) and imaging studies with 3 T magnetic resonance with cartilage analysis with T2 mapping sequences for cartilage analysis before and after treatment. In the study group, mean pre-treatment T2 relaxation time values were 44.2 ± 2.5 ms, considering all articular cartilage compartments, with significant reduction at the follow-up (p < 0.001). At the index compartment, mean pre-treatment T2 relaxation times values were 47.8 ± 3.6 ms, with statistically significant reduction at the follow-up (p < 0.001). Evaluation of focal cartilage lesions reported pre-treatment mean T2 value of 70.1 ± 13.0 ms and post-treatment mean value of 59.9 ± 4.6 ms (p < 0.001). From a clinical point of view, the pre-treatment WOMAC and VAS scores were 18.3 ± 4.5 and 7 (IQR:6-7.2), respectively; the post-treatment values were 7.3 ± 3.2 and 2 (IQR: 1.7-3.0), respectively (p < 0.001). In the control group, despite clinical improvement, we didn't find significant T2 values change during the follow-up period. In conclusion, T2 mapping is a valuable indicator for chondropathy and treatment-related changes over time.


Assuntos
Cartilagem Articular/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Osteoartrite do Joelho/diagnóstico por imagem , Osteoartrite do Joelho/terapia , Plasma Rico em Plaquetas , Adulto , Feminino , Fêmur , Humanos , Injeções Intra-Articulares , Masculino , Pessoa de Meia-Idade , Patela , Estudos Retrospectivos , Adulto Jovem
2.
Cancers (Basel) ; 14(7)2022 Mar 23.
Artigo em Inglês | MEDLINE | ID: mdl-35406399

RESUMO

In the last decades, nanotechnology has been used in a wide range of biomedical applications, both diagnostic and therapeutic. In this scenario, imaging techniques represent a fundamental tool to obtain information about the properties of nanoconstructs and their interactions with the biological environment in preclinical and clinical settings. This paper reviews the state of the art of the application of magnetic resonance imaging in the field of nanomedicine, as well as the use of nanoparticles as diagnostic and therapeutic tools, especially in cancer, including the characteristics that hinder the use of nanoparticles in clinical practice.

3.
J Clin Med ; 11(1)2021 Dec 27.
Artigo em Inglês | MEDLINE | ID: mdl-35011867

RESUMO

Osteoblastoma (OB) and osteoid osteoma (OO) are benign bone-forming tumors, with nearly identical basic microscopic features. The main difference is dimension (OO has usually a nidus measuring <2 cm in diameter). In addition, OB is biologically more active than OO, with a tendency to grow in size. Historically, treatments have included surgical resection and analgesics, although invasiveness and poor tolerance have led to the current standard of care moving toward interventional radiology, where radiofrequency ablation (RFA) represents the most diffuse technique. Magnetic resonance-guided focused ultrasound surgery (MRgFUS) has recently emerged as another innovative alternative treatment, providing tumor ablation through a needleless and ionizing radiation-free modality. In addition, this technique has the ability to guarantee a very precise and controlled increase in temperature, delivering small amounts of energy that can accurately destroy only the lesion, avoiding healthy surrounding tissues. The present review focuses on MRgFUS as the less invasive, safe, effective, and durable treatment option for the management of osteoid osteoma and osteoblastoma, including a description of technical details, indications and outcomes.

4.
Acta Biomed ; 92(S5): e2021403, 2021 09 10.
Artigo em Inglês | MEDLINE | ID: mdl-34505845

RESUMO

BACKGROUND AND AIM: Recently, there has been a growing interest in the use of Dixon sequence for knee MRI in order to save time spent on the scanner, and improving diagnostic utility. Our purpose was to compare the diagnostic performance of Dixon sequence on low-field MRI with the proton-density sequence on high-field MRI. METHODS: This prospective study included 40 patients who underwent 0.25T knee MRI, using the routine protocol with the addition of a sagittal 4-point Dixon sequence (SPED), and an additional sequence on 1.5T scanner, consisting in a fat-suppressed proton-density fast-spin-echo (FS PD-FSE). Two radiologists independently examined the images, evaluating the anatomic identification score and diagnostic performances of the two sequences. Interreader agreement was evaluated using an intraclass correlation coefficient (ICC). RESULTS: Final population counted 34 patients (36 knee MR images) with a mean age of 52.9 years (range, 18-75 years). Interreader agreement was very high except for cartilage injuries at medial femoral condyle and medial tibial plateau (ICC SPED: 0.757, ICC FS PD-FSE: 0.746), even if not statistically significant. There were no significant differences in mean signal-to-noise ratio (SNR), artifacts presence and diagnostic confidence between SPED and PD-FS sequence. CONCLUSIONS: Dixon sequences on low-field scanner have a comparable diagnostic accuracy to PD-FS sequence obtained on a high field scanner for knee MR imaging. (www.actabiomedica.it).


Assuntos
Doenças das Cartilagens , Traumatismos do Joelho , Adolescente , Adulto , Idoso , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Articulação do Joelho/diagnóstico por imagem , Imageamento por Ressonância Magnética , Pessoa de Meia-Idade , Estudos Prospectivos , Adulto Jovem
5.
Gland Surg ; 8(Suppl 3): S208-S215, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31559187

RESUMO

Magnetic resonance imaging (MRI) is the primary imaging tool for the evaluation of pituitary gland pathology. In the last decades, MRI with high-field scanners has become widely used in clinical practice, leading to significant improvements in image quality mainly thanks to a superior spatial resolution and signal intensity. Moreover, several advanced functional MRI sequences have been implemented for pituitary imaging, providing valuable information in diagnostic and presurgical planning of pituitary adenomas. Higher field strength presents however some technical pitfalls to be aware of. The purpose of this article is to review the state of the art of high-resolution MRI of the pituitary gland at 3 Tesla (3T), with a particular focus on the main benefits and the possible limitations of higher field imaging.

6.
Int J Artif Organs ; 42(12): 711-716, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-31238772

RESUMO

Echocardiographic strain and strain-rate imaging is a promising tool for the evaluation of myocardial segmental function, for the early detection of myocardial dysfunction, and for the prediction of reverse remodeling. We aimed at studying the changes in left and right ventricular function in pulsatile left ventricular assist device pediatric patients by two-dimensional echocardiography and two-dimensional speckle-tracking echocardiography. Echocardiographic and clinical data of patients implanted with a pulsatile-flow left ventricular assist device from 2011 to 2018 were retrospectively reviewed before and after implantation at 1, 3, and 6 months. A total of 18 patients were enrolled. Median age and weight at implantation were 9 months (5-23 months) and 5.85 kg (4.85-8.75 kg), respectively; median left ventricular assist device support was 181 (114.5-289.5) days. 13 patients (73%) were transplanted and 5 patients (27%) died. At follow-up: left ventricular ejection fraction increase at 1 month (p = 0.001) and 3 months (p = 0.01), left ventricular global longitudinal strain improvement at 1 month (p = 0.0008) and 3 months (p = 0.02), and right ventricular free-wall longitudinal strain increase at 1 month (p = 0.01). At short term after left ventricular assist device implantation, both left ventricular and right ventricular mechanics improved. The temporary benefit seems to decrease over time. The worsening of left ventricular function has been followed by a worsening of right ventricular function probably due to the ventricular interdependence.


Assuntos
Ecocardiografia/métodos , Ventrículos do Coração , Coração Auxiliar/efeitos adversos , Disfunção Ventricular , Cardiomiopatias/complicações , Criança , Análise de Falha de Equipamento/métodos , Feminino , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/fisiopatologia , Humanos , Masculino , Avaliação de Resultados em Cuidados de Saúde , Prognóstico , Fluxo Pulsátil , Reprodutibilidade dos Testes , Estudos Retrospectivos , Disfunção Ventricular/diagnóstico , Disfunção Ventricular/etiologia , Disfunção Ventricular/fisiopatologia , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA