Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Bioinformatics ; 11: 177, 2010 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-20377906

RESUMO

BACKGROUND: Time-of-flight mass spectrometry (TOF-MS) has the potential to provide non-invasive, high-throughput screening for cancers and other serious diseases via detection of protein biomarkers in blood or other accessible biologic samples. Unfortunately, this potential has largely been unrealized to date due to the high variability of measurements, uncertainties in the distribution of proteins in a given population, and the difficulty of extracting repeatable diagnostic markers using current statistical tools. With studies consisting of perhaps only dozens of samples, and possibly hundreds of variables, overfitting is a serious complication. To overcome these difficulties, we have developed a Bayesian inductive method which uses model-independent methods of discovering relationships between spectral features. This method appears to efficiently discover network models which not only identify connections between the disease and key features, but also organizes relationships between features--and furthermore creates a stable classifier that categorizes new data at predicted error rates. RESULTS: The method was applied to artificial data with known feature relationships and typical TOF-MS variability introduced, and was able to recover those relationships nearly perfectly. It was also applied to blood sera data from a 2004 leukemia study, and showed high stability of selected features under cross-validation. Verification of results using withheld data showed excellent predictive power. The method showed improvement over traditional techniques, and naturally incorporated measurement uncertainties. The relationships discovered between features allowed preliminary identification of a protein biomarker which was consistent with other cancer studies and later verified experimentally. CONCLUSIONS: This method appears to avoid overfitting in biologic data and produce stable feature sets in a network model. The network structure provides additional information about the relationships among features that is useful to guide further biochemical analysis. In addition, when used to classify new data, these feature sets are far more consistent than those produced by many traditional techniques.


Assuntos
Espectrometria de Massas/métodos , Proteômica/métodos , Teorema de Bayes , Biomarcadores/química , Reconhecimento Automatizado de Padrão
2.
Rapid Commun Mass Spectrom ; 24(1): 138-46, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-19960505

RESUMO

A computational technique is presented for the automated assignment of the multiple charge and multimer states (ionization states) in the time-of-flight (TOF) domain for matrix-assisted laser desorption/ionization (MALDI) spectra. Examples of the application of this technique include an improved, automatic calibration over the 2 to 70 kDa mass range and a reduced data redundancy after reconstruction of the molecular spectrum of only singly charged monomers. This method builds on our previously reported enhancement of broad-mass signal detection, and includes two steps: (1) an automated correction of the instrumental acquisition initial time delay, and (2) a recursive TOF detection of multiple charge states and singly charged multimers of molecular [MH](+) ions over the entire record range, based on MALDI methods. The technique is tested using calibration mixtures and pooled serum quality control samples acquired along with clinical study data. The described automated procedure improves the analysis and dimension reduction of MS data for comparative proteomics applications.


Assuntos
Algoritmos , Mapeamento de Peptídeos/métodos , Proteínas/análise , Proteínas/química , Espectrometria de Massas por Ionização por Electrospray/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Sequência de Aminoácidos , Misturas Complexas/análise , Misturas Complexas/química , Íons , Dados de Sequência Molecular
3.
Proteomics ; 8(8): 1530-8, 2008 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-18340636

RESUMO

We have developed an automated procedure for aligning peaks in multiple TOF spectra that eliminates common timing errors and small variations in spectrometer output. Our method incorporates high-resolution peak detection, re-binning, and robust linear data fitting in the time domain. This procedure aligns label-free (uncalibrated) peaks to minimize the variation in each peak's location from one spectrum to the next, while maintaining a high number of degrees of freedom. We apply our method to replicate pooled-serum spectra from multiple laboratories and increase peak precision (t/sigma(t)) to values limited only by small random errors (with sigma(t) less than one time count in 89 out of 91 instances, 13 peaks in seven datasets). The resulting high precision allowed for an order of magnitude improvement in peak m/z reproducibility. We show that the CV for m/z is 0.01% (100 ppm) for 12 out of the 13 peaks that were observed in all datasets between 2995 and 9297 Da.


Assuntos
Algoritmos , Proteínas Sanguíneas/análise , Reconhecimento Automatizado de Padrão , Proteoma/análise , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Humanos , Mapeamento de Peptídeos , Análise Serial de Proteínas
4.
Proteomics Clin Appl ; 5(7-8): 440-7, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21751409

RESUMO

PURPOSE: To demonstrate robust detection of biomarkers in broad-mass-range TOF-MS data. EXPERIMENTAL DESIGN: Spectra were obtained for two serum protein profiling studies: (i) 2-200 kDa for 132 patients, 67 healthy and 65 diagnosed as having adult T-cell leukemia and (ii) 2-100 kDa for 140 patients, 70 pairs, each with matched prostate-specific antigen (PSA) levels and biopsy-confirmed diagnoses of one benign and one prostate cancer. Signal processing was performed on raw spectra and peak data were normalized using four methods. Feature selection was performed using Bayesian Network Analysis and a classifier was tested on withheld data. Identification of candidate biomarkers was pursued. RESULTS: Integrated peak intensities were resolved over full spectra. Normalization using local noise values was superior to global methods in reducing peak correlations, reducing replicate variability and improving feature selection stability. For the leukemia data set, potential disease biomarkers were detected and were found to be predictive for withheld data. Preliminary assignments of protein IDs were consistent with published results and LC-MS/MS identification. No prostate-specific-antigen-independent biomarkers were detected in the prostate cancer data set. CONCLUSIONS AND CLINICAL RELEVANCE: Signal processing, local signal-to-noise (SNR) normalization and Bayesian Network Analysis feature selection facilitate robust detection and identification of biomarker proteins in broad-mass-range clinical TOF-MS data.


Assuntos
Biomarcadores/sangue , Proteínas Sanguíneas/análise , Leucemia-Linfoma de Células T do Adulto/diagnóstico , Hiperplasia Prostática/diagnóstico , Neoplasias da Próstata/diagnóstico , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Adulto , Algoritmos , Teorema de Bayes , Cromatografia de Afinidade , Feminino , Humanos , Leucemia-Linfoma de Células T do Adulto/sangue , Masculino , Antígeno Prostático Específico/sangue , Hiperplasia Prostática/sangue , Neoplasias da Próstata/sangue , Controle de Qualidade , Software
5.
J Proteome Res ; 6(11): 4517-24, 2007 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-17918874

RESUMO

Analysis of complex biological samples by MALDI-TOF mass spectrometry has been generally limited to the detection of low-mass protein (or protein fragment) peaks. We have extended the mass range of MALDI-TOF high-sensitivity detection by an order of magnitude through the combined optimization of instrument parameters, data processing, and sample preparation procedures for affinity capture. WCX, C3, and IMAC magnetic beads were determined to be complementary and most favorable for broad mass range protein profiling. Key instrument parameters for extending mass range included adjustment of the ADC offset and preamplifier filter values of the TOF detector. Data processing was improved by a combination of constant and quadratic down-sampling, preceded by exponential baseline subtraction, to increase sensitivity of signal peaks. This enhancement in broad mass range detection of protein signals will be of direct benefit in MS expression profiling studies requiring full linear range mass detection.


Assuntos
Proteômica/métodos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Proteínas Sanguíneas/química , Calibragem , Humanos , Magnetismo , Espectrometria de Massas , Peso Molecular , Mapeamento de Peptídeos , Peptídeos/química , Análise Serial de Proteínas , Proteínas/química , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
6.
Rapid Commun Mass Spectrom ; 20(11): 1661-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16636999

RESUMO

By applying time-domain filters to time-of-flight (TOF) mass spectrometry signals, we have simultaneously smoothed and narrowed spectra resulting in improved resolution and increased signal-to-noise ratios. This filtering procedure has an advantage over detailed curve fitting of spectra in the case of large dense spectra, when neither the location nor the number of mass peaks is known a priori. This time series method is directly applicable in the time lag optimization range, where point density per peak is constant. We present a systematic methodology to optimize the filters according to any desired figure of merit, illustrating the procedure by optimizing the signal-to-noise per unit bandwidth of matrix-assisted laser desorption/ionization (MALDI) data. We also introduce a nonlinear filter that reduces the spurious structure that often accompanies deconvolution filters. The net result of the application of these filters is that we can identify new structures in dense MALDI-TOF data, clearly showing small adducts to heavy biomolecules.


Assuntos
Algoritmos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Artefatos , Interpretação Estatística de Dados , Humanos , Dinâmica não Linear , Soro/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/estatística & dados numéricos
7.
Rapid Commun Mass Spectrom ; 20(11): 1670-8, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16637003

RESUMO

We have developed a peak deconvolution strategy that is applicable to the full mass range of a time-of-flight (TOF) spectrum. This strategy involves resampling a spectrum to create a time series that has equal peak widths (in time) across the entire spectrum, and then using the deconvolution filters we have previously described. We use this technique to deconvolve the protein mass spectra for blood serum and cell lysates acquired on three separate TOF instruments. Following deconvolution, we resolve spectral structures consistent with expected events such as multiply charged ions, matrix adducts and post-translational protein modifications. The deconvolution procedure produces a 40% improvement in the resolution and enhanced experimental sensitivity over the full length of the linear TOF record, up to m/z 150 000. This approach is particularly appropriate for automated data analysis and peak detection in dense TOF spectra.


Assuntos
Algoritmos , Proteínas/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/estatística & dados numéricos , Apolipoproteína A-I/análise , Líquidos Corporais/química , Calibragem , Interpretação Estatística de Dados , Entropia , Células Epiteliais/química , Humanos , Dinâmica não Linear , Processamento de Proteína Pós-Traducional , Soro/química , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos
8.
Clin Chem ; 51(1): 65-74, 2005 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-15550476

RESUMO

BACKGROUND: Measurement of peptide/protein concentrations in biological samples for biomarker discovery commonly uses high-sensitivity mass spectrometers with a surface-processing procedure to concentrate the important peptides. These time-of-flight (TOF) instruments typically have low mass resolution and considerable electronic noise associated with their detectors. The net result is unnecessary overlapping of peaks, apparent mass jitter, and difficulty in distinguishing mass peaks from background noise. Many of these effects can be reduced by processing the signal using standard time-series background subtraction, calibration, and filtering techniques. METHODS: Surface-enhanced laser desorption/ionization (SELDI) spectra were acquired on a PBS II instrument from blank, hydrophobic, and IMAC-Cu ProteinChip arrays (Ciphergen Biosystems, Inc.) incubated with calibration peptide mixtures or pooled serum. TOF data were recorded after single and multiple laser shots at different positions. Correlative analysis was used for time-series calibration. Target filters were used to suppress noise and enhance resolution after baseline removal and noise rescaling. RESULTS: The developed algorithms compensated for the electronic noise attributable to detector overload, removed the baseline caused by charge accumulation, detected and corrected mass peak jitter, enhanced signal amplitude at higher masses, and improved the resolution by using a deconvolution filter. CONCLUSIONS: These time-series techniques, when applied to SELDI-TOF data before any peak identification procedure, can improve the data to make the peak identification process simpler and more robust. These improvements may be applicable to most TOF instrumentation that uses analog (rather than counting) detectors.


Assuntos
Peptídeos/sangue , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Artefatos , Calibragem , Humanos , Análise Serial de Proteínas , Soro , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA