Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 114
Filtrar
1.
Hepatology ; 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38652643

RESUMO

BACKGROUND AND AIMS: Noninvasive tools assessing steatosis, such as ultrasonography-based 2D-attenuation imaging (ATI), are needed to tackle the worldwide burden of steatotic liver disease. This one-stage individual patient data (IPD) meta-analysis aimed to create an ATI-based steatosis grading system. APPROACH AND RESULTS: A systematic review (EMBASE + MEDLINE, 2018-2022) identified studies, including patients with histologically or magnetic resonance imaging proton-density fat fraction (MRI-PDFF)-verified ATI for grading steatosis (S0 to S3). One-stage IPD meta-analyses were conducted using generalized mixed models with a random study-specific intercept. Created ATI-based steatosis grading system (aS0 to aS3) was externally validated on a prospective cohort of patients with type 2 diabetes and metabolic dysfunction-associated steatotic liver disease (n=174, histologically and MRI-PDFF-verified steatosis). Eleven enrolled studies included 1374 patients, classified into S0, S1, S2, and S3 in 45.4%, 35.0%, 9.3%, and 10.3% of the cases. ATI was correlated with histological steatosis ( r = 0.60; 95% CI: 0.52, 0.67; p < 0.001) and MRI-PDFF ( r = 0.70; 95% CI: 0.66, 0.73; p < 0.001) but not with liver stiffness ( r = 0.03; 95% CI: -0.04, 0.11, p = 0.343). Steatosis grade was an independent factor associated with ATI (coefficient: 0.24; 95% CI: [0.22, 0.26]; p < 0.001). ATI marginal means within S0, S1, S2, and S3 subpopulations were 0.59 (95% CI: [0.58, 0.61]), 0.69 (95% CI [0.67, 0.71]), 0.78 (95% CI: [0.76, 0.81]), and 0.85 (95% CI: [0.83, 0.88]) dB/cm/MHz; all contrasts between grades were significant ( p < 0.0001). Three ATI thresholds were calibrated to create a new ATI-based steatosis grading system (aS0 to aS3, cutoffs: 0.66, 0.73, and 0.81 dB/cm/MHz). Its external validation showed Obuchowski measures of 0.84 ± 0.02 and 0.82 ± 0.02 with histologically based and MRI-PDFF-based references. CONCLUSIONS: ATI is a reliable, noninvasive marker of steatosis. This validated ATI-based steatosis grading system could be valuable in assessing patients with metabolic dysfunction-associated steatotic liver disease.

2.
J Hepatol ; 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38548067

RESUMO

BACKGROUND & AIMS: Non-invasive scores have been proposed to identify patients with fibrotic, metabolic dysfunction-associated steatohepatitis (MASH), who are at the highest risk of progression to complications of cirrhosis and may benefit from pharmacologic treatments. However, data in patients with type 2 diabetes (T2DM) are lacking. The aim of this multicenter prospective study was to perform a head-to-head comparison of FAST (FibroScan-aspartate aminotransferase [AST]), MAST (MRI-AST), MEFIB (magnetic resonance elastography [MRE] plus FIB-4), and FNI (fibrotic NASH index) for detecting fibrotic MASH in patients with T2DM. METHODS: A total of 330 outpatients with T2DM and biopsy-proven metabolic dysfunction-associated steatotic liver disease (MASLD) from the QUID-NASH study (NCT03634098), who underwent FibroScan, MRI-proton density fat fraction and MRE at the time of liver biopsy were studied. The main outcome was fibrotic MASH, defined as NAS ≥4 (with at least one point for each parameter) and fibrosis stage ≥2 (centrally reviewed). RESULTS: All data for score comparisons were available for 245 patients (median age 59 years, 65% male, median BMI 31 kg/m2; fibrotic MASH in 39%). FAST and MAST had similar accuracy (AUROCs 0.81 vs. 0.79, p = 0.41) but outperformed FNI (0.74; p = 0.01) and MEFIB (0.68; p <0.0001). When using original cut-offs, MAST outperformed FAST, MEFIB and FNI when comparing the percentage of correctly classified patients, in whom liver biopsy would be avoided (69% vs. 48%, 46%, 39%, respectively; p <0.001). When using cut-offs specific to our population, FAST outperformed FNI and MAST (56% vs. 40%, and 38%, respectively; p <0.001). CONCLUSION: Our findings show that FAST, MAST, MEFIB and FNI are accurate non-invasive tools to identify patients with T2DM and fibrotic MASH in secondary/tertiary diabetes clinics. Cut-offs adapted to the T2DM population should be considered. IMPACT AND IMPLICATIONS: Among patients with type 2 diabetes (T2DM), identifying those with metabolic dysfunction-associated steatohepatitis and significant fibrosis, who are the most at risk of developing clinical liver-related outcomes and who may benefit from pharmacologic treatments, is an unmet need. In this prospective multicenter study, we compared four non-invasive scores, three based on imaging (MRI or ultrasound technologies) and one on laboratory blood tests, for this purpose, using original and study-specific cut-offs. Our findings show that FAST, MAST, MEFIB and FNI are accurate non-invasive tools to identify patients with T2DM and fibrotic MASH in secondary/tertiary diabetes clinics. Cut-offs adapted to the T2DM population should be considered. TRIAL REGISTRATION NUMBER: NCT03634098.

3.
Eur Radiol ; 34(4): 2512-2523, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37823923

RESUMO

The pharmacokinetics of contrast media (CM) will determine how long safe waiting intervals between successive CT or MRI examinations should be. The Contrast Media Safety Committee has reviewed the data on pharmacokinetics of contrast media to suggest safe waiting intervals between successive contrast-enhanced imaging studies in relation to the renal function of the patient. CLINICAL RELEVANCE STATEMENT: Consider a waiting time between elective contrast-enhanced CT and (coronary) angiography with successive iodine-based contrast media administrations in patients with normal renal function (eGFR > 60 mL/min/1.73 m2) of optimally 12 h (near complete clearance of the previously administered iodine-based contrast media) and minimally 4 h (if clinical indication requires rapid follow-up). KEY POINTS: • Pharmacokinetics of contrast media will guide safe waiting times between successive administrations. • Safe waiting times increase with increasing renal insufficiency. • Iodine-based contrast media influence MRI signal intensities and gadolinium-based contrast agents influence CT attenuation.


Assuntos
Iodo , Insuficiência Renal , Humanos , Meios de Contraste/efeitos adversos , Listas de Espera , Angiografia Coronária
4.
Eur Radiol ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38573340

RESUMO

OBJECTIVES: Hysterosalpingography (HSG) is widely used for evaluating the fallopian tubes; however, controversies regarding the use of water- or oil-based iodine-based contrast media (CM) remain. The aim of this work was (1) to discuss reported pregnancy rates related to the CM type used, (2) to validate the used CM in published literature, (3) to discuss possible complications and side effects of CM in HSG, and (4) to develop guidelines on the use of oil-based CM in HSG. METHODS: A systematic literature search was conducted for original RCT studies or review/meta-analyses on using water-based and oil-based CM in HSG with fertility outcomes and complications. Nine randomized controlled trials (RCTs) and 10 reviews/meta-analyses were analyzed. Grading of the literature was performed based on the Oxford Centre for Evidence-Based Medicine (OCEBM) 2011 classification. RESULTS: An approximately 10% higher pregnancy rate is reported for oil-based CM. Side effects are rare, but oil-based CM have potentially more side effects on the maternal thyroid function and the peritoneum. CONCLUSIONS: 1. HSG with oil-based CM gives approximately 10% higher pregnancy rates. 2. External validity is limited, as in five of nine RCTs, the CM used is no longer on the market. 3. Oil-based CM have potentially more side effects on the maternal thyroid function and on the peritoneum. 4. Guideline: Maternal thyroid function should be tested before HSG with oil-based CM and monitored for 6 months after. CLINICAL RELEVANCE STATEMENT: Oil-based CM is associated with an approximately 10% higher chance of pregnancy compared to water-based CM after HSG. Although side effects are rare, higher iodine concentration and slower clearance of oil-based CM may induce maternal thyroid function disturbance and peritoneal inflammation and granuloma formation. KEY POINTS: • It is unknown which type of contrast medium, oil-based or water-based, is the optimal for HSG. • Oil-based contrast media give a 10% higher chance of pregnancy after HSG, compared to water-based contrast media. • From the safety perspective, oil-based CM can cause thyroid dysfunction and an intra-abdominal inflammatory response in the patient.

6.
Ultraschall Med ; 45(1): 36-46, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37748503

RESUMO

Dynamic contrast-enhanced ultrasound (DCE-US) is a technique to quantify tissue perfusion based on phase-specific enhancement after the injection of microbubble contrast agents for diagnostic ultrasound. The guidelines of the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB) published in 2004 and updated in 2008, 2011, and 2020 focused on the use of contrast-enhanced ultrasound (CEUS), including essential technical requirements, training, investigational procedures and steps, guidance regarding image interpretation, established and recommended clinical indications, and safety considerations. However, the quantification of phase-specific enhancement patterns acquired with ultrasound contrast agents (UCAs) is not discussed here. The purpose of this EFSUMB Technical Review is to further establish a basis for the standardization of DCE-US focusing on treatment monitoring in oncology. It provides some recommendations and descriptions as to how to quantify dynamic ultrasound contrast enhancement, and technical explanations for the analysis of time-intensity curves (TICs). This update of the 2012 EFSUMB introduction to DCE-US includes clinical aspects for data collection, analysis, and interpretation that have emerged from recent studies. The current study not only aims to support future work in this research field but also to facilitate a transition to clinical routine use of DCE-US.


Assuntos
Meios de Contraste , Neoplasias , Humanos , Ultrassonografia/métodos , Perfusão
7.
Kidney Int ; 103(5): 930-935, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36841476

RESUMO

Chronic kidney disease is a major medical problem, causing more than a million deaths each year worldwide. Peripheral kidney microvascular damage characterizes most chronic kidney diseases, yet noninvasive and quantitative diagnostic tools to measure this are lacking. Ultrasound Localization Microscopy (ULM) can assess tissue microvasculature with unprecedented resolution. Here, we optimized methods on 35 kidney transplants and studied the feasibility of ULM in seven human kidney allografts with a standard low frame rate ultrasound scanner to access microvascular damage. Interlobar, arcuate, cortical radial vessels, and part of the medullary organization were visible on ULM density maps. The medullary vasa recta can be seen but are not as clear as the cortical vessels. Acquisition parameters were derived from Contrast-Enhanced Ultrasound examinations by increasing the duration of the recorded clip at the same plane. ULM images were compared with Color Doppler, Advanced Dynamic Flow, and Superb Microvascular Imaging with a contrast agent. Despite some additional limitations due to movement and saturation artifacts, ULM identified vessels two to four times thinner compared with Doppler modes. The mean ULM smallest analyzable vessel cross section was 0.3 ± 0.2 mm in the seven patients. Additionally, ULM was able to provide quantitative information on blood velocities in the cortical area. Thus, this proof-of-concept study has shown ULM to be a promising imaging technique for qualitative and quantitative microvascular assessment. Imaging native kidneys in patients with kidney diseases will be needed to identify their ULM biomarkers.


Assuntos
Microscopia , Insuficiência Renal Crônica , Humanos , Microscopia/métodos , Rim/diagnóstico por imagem , Rim/irrigação sanguínea , Ultrassonografia/métodos , Microvasos/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico por imagem , Insuficiência Renal Crônica/cirurgia , Aloenxertos
8.
Artigo em Inglês | MEDLINE | ID: mdl-38072287

RESUMO

BACKGROUND & AIMS: Similarly to the controlled attenuation parameter (CAP), the ultrasound-based attenuation imaging (ATI) can quantify hepatic steatosis. We prospectively compared the performance of ATI and CAP for the diagnosis of hepatic steatosis in patients with type 2 diabetes and nonalcoholic fatty liver disease using histology and magnetic resonance imaging-proton density fat fraction (MRI-PDFF) as references. METHODS: Patients underwent ATI and CAP measurement, MRI, and biopsy on the same day. Steatosis was classified as S0, S1, S2, and S3 on histology (<5%, 5%-33%, 33%-66%, and >66%, respectively) while the thresholds of 6.4%, 17.4%, and 22.1%, respectively, were used for MRI-PDFF. The area under the curve (AUC) of ATI and CAP was compared using a DeLong test. RESULTS: Steatosis could be evaluated in 191 and 187 patients with MRI-PDFF and liver biopsy, respectively. For MRI-PDFF steatosis, the AUC of ATI and CAP were 0.86 (95% confidence interval [CI], 0.81-0.91) vs 0.69 (95% CI, 0.62-0.75) for S0 vs S1-S3 (P = .02) and 0.71 (95% CI, 0.64-0.77) vs 0.69 (95% CI, 0.61-0.75) for S0-S1 vs S2-S3 (P = .60), respectively. For histological steatosis, the AUC of ATI and CAP were 0.92 (95% CI, 0.87-0.95) vs 0.95 (95% CI, 0.91-0.98) for S0 vs S1-S3 (P = .64) and 0.79 (95% CI, 0.72-0.84) vs 0.76 (95% CI, 0.69-0.82) for S0-S1 vs S2-S3 (P = .61), respectively. CONCLUSION: ATI may be used as an alternative to CAP for the diagnosis and quantification of steatosis, in patients with type 2 diabetes and nonalcoholic fatty liver disease.

9.
Eur Radiol ; 33(12): 8703-8714, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37405502

RESUMO

OBJECTIVES: Contrast enhancement by MRI done early after cryoablation for renal malignancies may suggest residual tumor (RT). However, we have observed MRI enhancement within 48 h of cryoablation in patients who had no contrast enhancement 6 weeks later. Our purpose was to identify features of 48-h contrast enhancement in patients without RT. METHODS: This single-center retrospective study included consecutive patients who underwent percutaneous cryoablation of renal malignancies in 2013-2020, exhibited cryoablation-zone MRI contrast enhancement 48 h later, and had available 6-week MRI scans. Persistent or growing CE at 6 weeks vs. 48 h was classified as RT. A washout index was calculated for each 48-h MRI, and its performance for predicting RT was assessed by receiver operating characteristic curve analysis. RESULTS: We included 60 patients with 72 cryoablation procedures and 83 cryoablation zones exhibiting 48-h contrast enhancement; mean age was 66 ± 17 years. Clear-cell renal cell carcinoma accounted for 95% of tumors. Of the 83 48-h enhancement zones, RT was observed in eight while 75 were benign. The 48-h enhancement was consistently visible at the arterial phase. Washout was significantly associated with RT (p < 0.001) and gradually increasing contrast enhancement with benignity (p < 0.009). A washout index below - 1.1 predicted RT with 88% sensitivity and 84% specificity. CONCLUSION: MRI contrast enhancement 48 h after cryoablation of renal malignancies was usually benign. Washout was associated with residual tumor, with a washout index value below - 1.1 exhibiting good performance in predicting residual tumor. These findings may help to guide decisions about repeat cryoablation. CLINICAL RELEVANCE STATEMENT: Magnetic resonance imaging contrast enhancement 48 h after cryoablation of renal malignancies rarely indicates residual tumor, which is characterized by washout with a washout index lower than - 1.1. KEY POINTS: • Contrast enhancement at the arterial phase of magnetic resonance imaging done 48 h after cryoablation of a renal malignancy is usually benign. • Residual tumor manifesting as contrast enhancement at the arterial phase is characterized by subsequent marked washout. • A washout index below - 1.1 has 88% sensitivity and 84% specificity for residual tumor.


Assuntos
Carcinoma de Células Renais , Criocirurgia , Neoplasias Renais , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Carcinoma de Células Renais/diagnóstico por imagem , Carcinoma de Células Renais/cirurgia , Criocirurgia/métodos , Estudos Retrospectivos , Neoplasia Residual , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Neoplasias Renais/patologia , Imageamento por Ressonância Magnética/métodos , Meios de Contraste
10.
Eur Radiol ; 2023 Dec 14.
Artigo em Inglês | MEDLINE | ID: mdl-38092951

RESUMO

OBJECTIVES: It is uncertain whether modern iodine-based or gadolinium-based contrast media (CM) administration can lead to increased symptoms in patients with myasthenia gravis. METHODS: A systematic search in Medline was conducted for studies describing the symptomatology of myasthenia gravis patients before and after receiving intravenous (IV) CM and having a matched control group of myasthenia gravis patients who did not receive IV CM. RESULTS: Three retrospective studies were selected with a total of 374 myasthenia gravis patients who received iodine-based CM and a total of 313 myasthenia gravis patients who underwent unenhanced CT and served as controls. Pooling of the data from the three retrospective studies showed that in 23 of 374 patients, increased symptoms after iodine-based CM administration were described (6.1%). Increased symptomatology also occurred in 11 of 313 patients after unenhanced CT (3.5%). When looking more deeply into the data of the three studies, conflicting results were found, as two articles did not find any relationship between CM and myasthenia gravis symptoms. The remaining study only found a significant increase in symptomatology within 1 day after CT scanning: seven patients (6.3%) in the contrast-enhanced CT group and one patient (0.6%) in the unenhanced CT group (p = 0.01). CONCLUSIONS: There is limited evidence on the relationship between CM and myasthenia gravis symptoms. In the vast majority of myasthenia gravis patients, CM are safe. Probably, in less than 5% of the patients, iodine-based CM administration may lead to increased severity of the symptoms within the first 24 h after administration. CLINICAL RELEVANCE STATEMENT: Be aware that intravenous administration of iodine-based contrast media can lead to an increase of symptoms in patients with myasthenia gravis within the first 24 h. This can probably happen in less than 5% of the patients. KEY POINTS: • It is unclear whether modern contrast media can lead to increased symptoms in myasthenia gravis patients after intravenous administration. • There seems to be a small risk of increased myasthenia gravis symptoms within 24 h after intravenous administration of iodine-based contrast media, probably in less than 5% of the administrations. • Gadolinium-based contrast media are safe for patients with myasthenia gravis.

11.
Eur Radiol ; 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-38060004

RESUMO

The Contrast Media Safety Committee of the European Society of Urogenital Radiology has, together with the Preanalytical Phase Working Group of the EFLM Science Committee, reviewed the literature and updated its recommendations to increase awareness and provide insight into these interferences. CLINICAL RELEVANCE STATEMENT: Contrast Media may interfere with clinical laboratory tests. Awareness of potential interference may prevent unwanted misdiagnosis. KEY POINTS: • Contrast Media may interfere with clinical laboratory tests; therefore awareness of potential interference may prevent unwanted misdiagnosis. • Clinical Laboratory tests should be performed prior to radiological imaging with contrast media or alternatively, blood or urine collection should be delayed, depending on kidney function.

12.
Acta Radiol ; 64(5): 1730-1737, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36617943

RESUMO

BACKGROUND: Early detection can prevent the initial stages of fibrosis from progressing to cirrhosis. PURPOSE: To evaluate an algorithm combining three echographic indicators and elastographic measurements to screen for hepatic fibrosis in an unselected population. MATERIAL AND METHODS: From May 2017 to June 2018, all patients with no history and no known chronic liver disease who were referred for an ultrasound (US) were prospectively included in eight hospitals. The indicators being sought were liver surface irregularity, demodulation of hepatic veins, and spleen length >110 mm. Patients presenting at least one of these underwent elastography measurements with virtual touch quantification (VTQ) or supersonic shear imaging (SSI). If elastography was positive, patients were referred to hepatologist for fibrosis evaluation. Reference standard was obtained by FibroMeterVCTE or biopsy. A FibroMeterVCTE result >0.384 indicated a "necessary referral" to a hepatologist. RESULTS: Of the 1501 patients included, 504 (33.6%) were positive for at least one US indicator. All of them underwent US elastography, with 85 being positive. Of the patients, 58 (3.6%) had a consultation with a liver specialist: 21 had positive FibroMeterVCTE and nine had an indication of biopsy for suspicion of fibrosis. This screening algorithm made it possible to diagnose 1.6% of patients in our population with unknown fibrosis. Of the patients, 50% referred to the liver specialist were "necessary referrals." CONCLUSION: Our study suggests that three simple US indicators with no systematic elastographic measurement could be applied in day-to-day practice to look for hepatic fibrosis in an unsuspected population allowing relevant referrals to a hepatologist.


Assuntos
Técnicas de Imagem por Elasticidade , Humanos , Técnicas de Imagem por Elasticidade/métodos , Cirrose Hepática/patologia , Fígado/diagnóstico por imagem , Fígado/patologia , Fibrose , Algoritmos , Ultrassonografia Doppler
13.
Eur Radiol ; 32(5): 3056-3066, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35175378

RESUMO

NEED FOR A REVIEW: Guidelines for management and prevention of contrast media extravasation have not been updated recently. In view of emerging research and changing working practices, this review aims to inform update on the current guidelines. AREAS COVERED: In this paper, we review the literature pertaining to the pathophysiology, diagnosis, risk factors and treatments of contrast media extravasation. A suggested protocol and guidelines are recommended based upon the available literature. KEY POINTS: • Risk of extravasation is dependent on scanning technique and patient risk factors. • Diagnosis is mostly clinical, and outcomes are mostly favourable. • Referral to surgery should be based on clinical severity rather than extravasated volume.


Assuntos
Meios de Contraste , Extravasamento de Materiais Terapêuticos e Diagnósticos , Humanos , Administração Intravenosa , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Extravasamento de Materiais Terapêuticos e Diagnósticos/prevenção & controle , Fatores de Risco
14.
Eur Surg Res ; 63(1): 19-24, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-34289472

RESUMO

INTRODUCTION: Indeterminate renal cysts may require several imaging modalities before clinical decision. The aim of this study was to investigate the effect of the imaging modality used to characterize indeterminate renal cysts on the pathological findings after surgical resection. METHODS: From our institutional database, we identified all patients surgically treated for Bosniak III renal masses between January 2008 and January 2018. All complex renal cysts were characterized with a combination of computed tomography (CT) and/or magnetic resonance imaging (MRI), and/or contrast-enhanced ultrasound (CEUS) and discussed during a multidisciplinary tumor board. Potential association between clinical/radiological characteristics and the pathological findings were investigated, using univariate and multivariate analyses. RESULTS: Of the 52 renal cystic lesions surgically removed, with a preoperative diagnosis of Bosniak III renal cyst, 19 (37%) were malignant and 33 (63%) were benign. The proportion of malignant lesions decreased from 47% when the renal cyst was characterized with cross-sectional imaging (CT and/or MRI) to 17% when the diagnosis required CEUS in addition to cross-sectional imaging. In multivariate analysis, prior history of renal cell carcinoma was associated with a higher risk of malignancy (p = 0.016) and diagnosis made with CEUS was associated with a lower risk of malignancy (p = 0.040). CONCLUSION: We found that using CEUS in addition to cross-sectional imaging to characterize indeterminate renal cysts tends to redefine Bosniak III as lesions with a lower risk of malignancy and can lead to overclassification.


Assuntos
Cistos , Doenças Renais Císticas , Estudos de Casos e Controles , Meios de Contraste , Humanos , Doenças Renais Císticas/diagnóstico por imagem , Doenças Renais Císticas/patologia , Ultrassonografia/métodos
15.
Kidney Int ; 99(1): 218-226, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32898570

RESUMO

We have previously shown that ultrasonography can detect hyperechogenic crystal deposits in the kidney medulla of patients with gout. In this cross-sectional study we investigated the frequency and clinical correlates of hyperechogenic kidney medulla in 502 consecutive primary consultants for gout (ACR/EULAR criteria) at the Vien Gut medical center in Ho Chi Minh City, Vietnam. None of these patients received urate-lowering drugs. Kidney medulla echogenicity on B-mode ultrasonography was compared to that of the kidney cortex. Overall, 36% patients showed a hyperechoic pattern of Malpighi pyramids. On univariate analysis, the pattern was significantly associated with age, estimated gout duration, steroid-dependency, clinical tophi, urate arthropathy, double contour thickness at the scanned joints, coronary heart disease, arterial hypertension, hyperuricemia, proteinuria, leukocyturia, and decreased estimated glomerular filtration rate. On multivariable analysis, the hyperechoic pattern was associated with estimated disease duration, clinical tophi, urate arthropathy, double contour thickness and decreased estimated glomerular filtration rate. No hyperechoic pattern was observed in 515 consecutive consultants without gout. Thus, hyperechoic kidney medulla was frequently demonstrated in Vietnamese patients with tophaceous gout and associated with features of tubulointerstitial nephritis. This finding revives the hypothesis of microcrystalline nephropathy of gout, predominantly seen in untreated gouty patients, which could be an important target for urate-lowering therapy.


Assuntos
Gota , Hiperuricemia , Estudos Transversais , Gota/diagnóstico por imagem , Gota/tratamento farmacológico , Gota/epidemiologia , Humanos , Medula Renal , Ácido Úrico
16.
World J Urol ; 39(3): 661-676, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32306060

RESUMO

The diagnosis of prostate cancer (PCa) can be challenging due to the limited performance of current diagnostic tests, including PSA, digital rectal examination and transrectal conventional US. Multiparametric MRI has improved PCa diagnosis and is recommended prior to biopsy; however, mp-MRI does miss a substantial number of PCa. Advanced US modalities include transrectal prostate elastography and contrast-enhanced US, as well as improved B-mode, micro-US and micro-Doppler techniques. These techniques can be combined to define a novel US approach, multiparametric US (mp-US). Mp-US improves PCa diagnosis but is not sufficiently accurate to obviate the utility of mp-MRI. Mp-US using advanced techniques and mp-MRI provide complementary information which will become even more important in the era of focal therapy, where precise identification of PCa location is needed.


Assuntos
Neoplasias da Próstata/diagnóstico por imagem , Adulto , Idoso , Meios de Contraste , Técnicas de Imagem por Elasticidade , Humanos , Masculino , Ultrassonografia/métodos
17.
Ultraschall Med ; 42(2): 154-166, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33307594

RESUMO

The well-established Bosniak renal cyst classification is based on contrast-enhanced computed tomography determining the malignant potential of cystic renal lesions. Ultrasound has not been incorporated into this pathway. However, the development of ultrasound contrast agents coupled with the superior resolution of ultrasound makes it possible to redefine the imaging of cystic renal lesions. In this position statement, an EFSUMB Expert Task Force reviews, analyzes, and describes the accumulated knowledge and limitations and presents the current position on the use of ultrasound contrast agents in the evaluation of cystic renal lesions.


Assuntos
Cistos , Doenças Renais Císticas , Neoplasias Renais , Meios de Contraste , Cistos/diagnóstico por imagem , Humanos , Doenças Renais Císticas/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Ultrassonografia
18.
AJR Am J Roentgenol ; 214(3): 579-587, 2020 03.
Artigo em Inglês | MEDLINE | ID: mdl-31770020

RESUMO

OBJECTIVE. Clear cell papillary renal cell carcinoma (RCC), an entity with strikingly indolent behavior, recently was added to the World Health Organization classification of renal tumors and represents the fourth most common histologic type of renal cell carcinoma. This article aims to describe the imaging features of clear cell papillary RCC along with its clinical and pathologic characteristics. MATERIALS AND METHODS. This retrospective study consisted of 27 patients with 44 clear cell papillary RCC tumors. The inclusion criteria were a pathologically proven clear cell papillary RCC and the availability of preoperative imaging including at least CT or MRI. Two experienced radiologists performed the imaging analysis independently. RESULTS. Patients (mean age, 62 years old) presented with renal failure in 26% of cases, and four had a tumor-predisposing disease. Multiple clear cell papillary RCC tumors occurred in 5 of the 27 patients. Two imaging patterns were recognizable. Solid clear cell papillary RCC (n = 23, 52%) presented as heterogeneous tumors with minor cystic changes (74%) and rarely exhibited calcifications (10%). All solid tumors showed hyperintensity on T2-weighted images compared with renal cortex and maximal enhancement on corticomedullary phase with a delayed washout. Cystic clear cell papillary RCC (n = 21, 48%) were classified as Bosniak IV (57%), III (33%), or IIF (10%), with a predominant unilocular pattern (76%). Pathologic stage according to TNM classification was mostly pT1a and low grade on nucleolar grade. All patients were alive at the date of last follow-up after treatment with no metastasis or recurrence. CONCLUSION. Clear cell papillary RCC exhibits two imaging patterns including cystic and solid in almost equal proportion. Imaging characteristics of solid clear cell papillary RCC including high signal T2 intensity and early arterial enhancement are unexpectedly distinct from papillary RCC and very similar to clear cell RCC.


Assuntos
Carcinoma Papilar/diagnóstico por imagem , Carcinoma de Células Renais/diagnóstico por imagem , Neoplasias Renais/diagnóstico por imagem , Adulto , Idoso , Idoso de 80 Anos ou mais , Biópsia , Carcinoma Papilar/patologia , Carcinoma de Células Renais/patologia , Meios de Contraste , Feminino , Humanos , Neoplasias Renais/patologia , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Gradação de Tumores , Estadiamento de Neoplasias , Estudos Retrospectivos , Tomografia Computadorizada por Raios X
19.
Ultraschall Med ; 41(5): 562-585, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32707595

RESUMO

The present, updated document describes the fourth iteration of recommendations for the hepatic use of contrast enhanced ultrasound (CEUS), first initiated in 2004 by the European Federation of Societies for Ultrasound in Medicine and Biology (EFSUMB). The previous updated editions of the guidelines reflected changes in the available contrast agents and updated the guidelines not only for hepatic but also for non-hepatic applications.The 2012 guideline requires updating as previously the differences of the contrast agents were not precisely described and the differences in contrast phases as well as handling were not clearly indicated. In addition, more evidence has been published for all contrast agents. The update also reflects the most recent developments in contrast agents, including the United States Food and Drug Administration (FDA) approval as well as the extensive Asian experience, to produce a truly international perspective.These guidelines and recommendations provide general advice on the use of ultrasound contrast agents (UCA) and are intended to create standard protocols for the use and administration of UCA in liver applications on an international basis to improve the management of patients.


Assuntos
Meios de Contraste , Ultrassonografia , Meios de Contraste/normas , Humanos , Ultrassonografia/normas
20.
Int J Hyperthermia ; 36(1): 666-676, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31317800

RESUMO

Background: Thermal ablation is a minimally invasive technique that is gradually acknowledged as an effective alternative to surgery to treat thyroid nodules. Two main techniques have been described: radiofrequency (RFA) and laser ablation. Objective: To evaluate the safety and efficacy of the two main techniques (RFA and laser ablation) for the treatment of benign thyroid nodules. Patients: This bicentric retrospective study included 166 consecutive patients, who received clinical, biological and ultrasound evaluations for thyroid nodules, from October 2013 to November 2017. Methods: One of the two techniques was proposed if a nodule was proven to be benign after fine needle aspiration cytology or micro-biopsy. Adverse events and outcomes (symptoms, nodule reduction) were assessed at 6 weeks and 6, 12, and 18 months after treatment. Results: One hundred and eighty-nine nodules (mean size 17.5 ± 16.9 mL, 86.1% palpable) were treated by RFA (n = 108 (57.1%)) or laser ablation (n = 81 (42.9%)) in 166 patients (80.1% women, mean age 51.7 years). Two cases of transient recurrent laryngeal nerve palsy, one hematoma, and two successfully drained abscesses (5/166 = 3%) were observed. Clinical symptoms improved significantly in the two groups (anterior cervical discomfort -83.6%, esthetic complaints -84.9% and dysphagia -86.4%). Nodule volume (mL) decreased significantly (baseline vs. 18 months) from 20.4 ± 18.6 to 5.8 ± 6.6 (-75%) in the RFA, and from 13.6 ± 13.3 to 3.4 ± 4.1 (-83.9%) in the laser ablation groups. Conclusions: Transient but potentially serious adverse events were reported in 3% of patients. A significant volumetric reduction was achieved with both techniques, regardless of nodule's characteristics, at 18 months.


Assuntos
Ablação por Cateter , Terapia a Laser , Nódulo da Glândula Tireoide/cirurgia , Abscesso/etiologia , Adulto , Ablação por Cateter/efeitos adversos , Doenças dos Nervos Cranianos/etiologia , Feminino , Hematoma/etiologia , Humanos , Nervos Laríngeos , Terapia a Laser/efeitos adversos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA