RESUMO
OBJECTIVE: Postoperative delirium (POD) can occur in up to 50% of older patients undergoing cardiovascular surgery, resulting in hospitalization and significant morbidity and mortality. This study aimed to determine whether intraoperative neurophysiologic monitoring (IONM) modalities can be used to predict delirium in patients undergoing cardiovascular surgery. DESIGN: Adult patients undergoing cardiovascular surgery with IONM between 2019 and 2021 were reviewed retrospectively. Delirium was assessed multiple times using the Intensive Care Delirium Screening Checklist (ICDSC). Patients with an ICDSC score ≥4 were considered to have POD. Significant IONM changes were evaluated based on a visual review of electroencephalography (EEG) and somatosensory evoked potentials data and documentation of significant changes during surgery. SETTING: University of Pittsburgh Medical Center hospitals. PARTICIPANTS: Patients 18 years old and older undergoing cardiovascular surgery with IONM monitoring. MEASUREMENTS AND MAIN RESULTS: Of the 578 patients undergoing cardiovascular surgery with IONM, 126 had POD (21.8%). Significant IONM changes were noted in 134 patients, of whom 49 patients had delirium (36.6%). In contrast, 444 patients had no IONM changes during surgery, of whom 77 (17.3%) patients had POD. Upon multivariate analysis, IONM changes were associated with POD (odds ratio 2.12; 95% CI 1.31-3.44; p < 0.001). Additionally, baseline EEG abnormalities were associated with POD (p = 0.002). CONCLUSION: Significant IONM changes are associated with an increased risk of POD in patients undergoing cardiovascular surgery. These findings offer a basis for future research and analysis of EEG and somatosensory evoked potential monitoring to predict, detect, and prevent POD.
Assuntos
Delírio do Despertar , Monitorização Neurofisiológica Intraoperatória , Adulto , Humanos , Adolescente , Estudos Retrospectivos , Potenciais Somatossensoriais Evocados/fisiologia , Monitorização Neurofisiológica Intraoperatória/métodos , Eletroencefalografia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controleRESUMO
PURPOSE: To evaluate the diagnostic accuracy of intraoperative somatosensory evoked potential (SSEP) monitoring and types of SSEP changes in predicting the risk of postoperative neurological outcomes during correction surgery for idiopathic scoliosis (IS) in the pediatric age group (≤ 21 years). METHODS: Database review was performed to identify literature on pediatric patients with IS who underwent correction with intraoperative neuromonitoring. The sensitivity, specificity, and diagnostic odds ratio (DOR) of transient and persistent SSEP changes and complete SSEP loss in predicting postoperative neurological deficits were calculated. RESULTS: Final analysis included 3778 patients. SSEP changes had a sensitivity of 72.9%, specificity of 96.8%, and DOR of 102.3, while SSEP loss had a sensitivity of 41.8%, specificity of 99.3%, and DOR of 133.2 for predicting new neurologic deficits. Transient and persistent SSEP changes had specificities of 96.8% and 99.1%, and DORs of 16.6 and 59, respectively. CONCLUSION: Intraoperative SSEP monitoring can predict perioperative neurological injury and improve surgical outcomes in pediatric scoliosis fusion surgery. LEVEL OF EVIDENCE: Level 2. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .
Assuntos
Monitorização Neurofisiológica Intraoperatória , Procedimentos Ortopédicos , Escoliose , Humanos , Criança , Adulto Jovem , Adulto , Escoliose/diagnóstico , Escoliose/cirurgia , Potenciais Somatossensoriais Evocados/fisiologia , Monitorização Intraoperatória , Procedimentos Neurocirúrgicos , Potencial Evocado Motor/fisiologia , Estudos RetrospectivosRESUMO
PURPOSE: The primary aim of this study was to evaluate whether TcMEP alarms can predict the occurrence of postoperative neurological deficit in patients undergoing lumbar spine surgery. The secondary aim was to determine whether the various types of TcMEP alarms including transient and persistent changes portend varying degrees of injury risk. METHODS: This was a systematic review and meta-analysis of the literature from PubMed, Web of Science, and Embase regarding outcomes of transcranial motor-evoked potential (TcMEP) monitoring during lumbar decompression and fusion surgery. The sensitivity, specificity, and diagnostic odds ratio (DOR) of TcMEP alarms for predicting postoperative deficit were calculated and presented with forest plots and a summary receiver operating characteristic curve. RESULTS: Eight studies were included, consisting of 4923 patients. The incidence of postoperative neurological deficit was 0.73% (36/4923). The incidence of deficits in patients with significant TcMEP changes was 11.79% (27/229), while the incidence in those without changes was 0.19% (9/4694). All TcMEP alarms had a pooled sensitivity and specificity of 63 and 95% with a DOR of 34.92 (95% CI 7.95-153.42). Transient and persistent changes had sensitivities of 29% and 47%, specificities of 96% and 98%, and DORs of 8.04 and 66.06, respectively. CONCLUSION: TcMEP monitoring has high specificity but low sensitivity for predicting postoperative neurological deficit in lumbar decompression and fusion surgery. Patients who awoke with new postoperative deficits were 35 times more likely to have experienced TcMEP changes intraoperatively, with persistent changes indicating higher risk of deficit than transient changes. LEVEL OF EVIDENCE II: Diagnostic Systematic Review.
Assuntos
Potencial Evocado Motor , Monitorização Neurofisiológica Intraoperatória , Humanos , Potencial Evocado Motor/fisiologia , Procedimentos Neurocirúrgicos , Sensibilidade e Especificidade , Região Lombossacral , DescompressãoRESUMO
The subthalamic nucleus (STN) is proposed to participate in pausing, or alternately, in dynamic scaling of behavioral responses, roles that have conflicting implications for understanding STN function in the context of deep brain stimulation (DBS) therapy. To examine the nature of event-related STN activity and subthalamic-cortical dynamics, we performed primary motor and somatosensory electrocorticography while subjects (n = 10) performed a grip force task during DBS implantation surgery. Phase-locking analyses demonstrated periods of STN-cortical coherence that bracketed force transduction, in both beta and gamma ranges. Event-related causality measures demonstrated that both STN beta and gamma activity predicted motor cortical beta and gamma activity not only during force generation but also prior to movement onset. These findings are consistent with the idea that the STN participates in motor planning, in addition to the modulation of ongoing movement. We also demonstrated bidirectional information flow between the STN and somatosensory cortex in both beta and gamma range frequencies, suggesting robust STN participation in somatosensory integration. In fact, interactions in beta activity between the STN and somatosensory cortex, and not between STN and motor cortex, predicted PD symptom severity. Thus, the STN contributes to multiple aspects of sensorimotor behavior dynamically across time.
Assuntos
Estimulação Encefálica Profunda/métodos , Eletrocorticografia/métodos , Força da Mão/fisiologia , Córtex Motor/fisiologia , Córtex Somatossensorial/fisiologia , Núcleo Subtalâmico/fisiologia , Adulto , Idoso , Eletrodos Implantados , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Desempenho Psicomotor/fisiologiaRESUMO
The sensorimotor cortex is somatotopically organized to represent the vocal tract articulators such as lips, tongue, larynx, and jaw. How speech and articulatory features are encoded at the subcortical level, however, remains largely unknown. We analyzed LFP recordings from the subthalamic nucleus (STN) and simultaneous electrocorticography recordings from the sensorimotor cortex of 11 human subjects (1 female) with Parkinson's disease during implantation of deep-brain stimulation (DBS) electrodes while they read aloud three-phoneme words. The initial phonemes involved either articulation primarily with the tongue (coronal consonants) or the lips (labial consonants). We observed significant increases in high-gamma (60-150 Hz) power in both the STN and the sensorimotor cortex that began before speech onset and persisted for the duration of speech articulation. As expected from previous reports, in the sensorimotor cortex, the primary articulators involved in the production of the initial consonants were topographically represented by high-gamma activity. We found that STN high-gamma activity also demonstrated specificity for the primary articulator, although no clear topography was observed. In general, subthalamic high-gamma activity varied along the ventral-dorsal trajectory of the electrodes, with greater high-gamma power recorded in the dorsal locations of the STN. Interestingly, the majority of significant articulator-discriminative activity in the STN occurred before that in sensorimotor cortex. These results demonstrate that articulator-specific speech information is contained within high-gamma activity of the STN, but with different spatial and temporal organization compared with similar information encoded in the sensorimotor cortex.SIGNIFICANCE STATEMENT Clinical and electrophysiological evidence suggest that the subthalamic nucleus (STN) is involved in speech; however, this important basal ganglia node is ignored in current models of speech production. We previously showed that STN neurons differentially encode early and late aspects of speech production, but no previous studies have examined subthalamic functional organization for speech articulators. Using simultaneous LFP recordings from the sensorimotor cortex and the STN in patients with Parkinson's disease undergoing deep-brain stimulation surgery, we discovered that STN high-gamma activity tracks speech production at the level of vocal tract articulators before the onset of vocalization and often before related cortical encoding.
Assuntos
Mapeamento Encefálico/métodos , Eletrocorticografia/métodos , Estimulação Luminosa/métodos , Córtex Sensório-Motor/fisiologia , Fala/fisiologia , Núcleo Subtalâmico/fisiologia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
Somatosensory evoked potentials (SSEPs) are utilized during aneurysm clipping to detect intraoperative ischemia. We assess the diagnostic accuracy of SSEPs in predicting perioperative stroke during aneurysm clipping. A retrospective review was conducted of 429 consecutive patients who underwent surgical clipping for ruptured and unruptured cerebral aneurysms with intraoperative SSEP monitoring from 2006 to 2013. The relationship between perioperative stroke and SSEP changes was analyzed by calculating the sensitivity, specificity, and area under a Receiving Operating Characteristic curve. Sensitivity and specificity were 42% and 90%, respectively. Area under the curve was 0.66 (95% confidence interval, 0.53-0.79). Reclassification of reversible temporary clip changes to correct for paradoxical classification of SSEP false positives raised the sensitivity from 42 to 65% (p = 0.041, Chi squared test). EEG (electroencephalography) changes increased the specificity (98% vs. 90%, p < 0.001, McNemar's test), but not sensitivity (48% vs. 42%, p = 0.621, McNemar's test) of SSEPs for perioperative stroke. A stepwise logistic regression model selected SSEP amplitude loss (p = 0.006, OR = 3.7 [95% CI 1.5-9.2]) and the SSEP change duration (p = 0.034, OR = 1.8 [95% CI 1.1-3.1]) as independent predictors of perioperative stroke. SSEP changes induced by temporary clipping were highly reversible compared to other SSEP changes (94% vs. 60%, p = 0.003, Fisher exact test), and typically responded to clip removal or readjustment. SSEP changes have high specificity and modest sensitivity for perioperative stroke. Stroke risk is a function of both the magnitude of SSEP amplitude loss and the duration of its loss. Given the modest sensitivity, patients may benefit from multimodal monitoring including motor-evoked potentials during cerebral aneurysm surgery.
Assuntos
Aneurisma Intracraniano/diagnóstico , Aneurisma Intracraniano/cirurgia , Monitorização Intraoperatória/instrumentação , Procedimentos Neurocirúrgicos , Adulto , Idoso , Alarmes Clínicos , Eletroencefalografia/métodos , Potencial Evocado Motor/fisiologia , Reações Falso-Positivas , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória , Masculino , Pessoa de Meia-Idade , Monitorização Intraoperatória/métodos , Período Perioperatório , Valor Preditivo dos Testes , Curva ROC , Análise de Regressão , Reprodutibilidade dos Testes , Estudos Retrospectivos , Risco , Sensibilidade e Especificidade , Resultado do Tratamento , Adulto JovemRESUMO
INTRODUCTION: Intra-operative stroke (IOS) is associated with poor clinical outcome as detection is often delayed and time of symptom onset or patient's last known well (LKW) is uncertain. Intra-operative neurophysiological monitoring (IONM) is uniquely capable of detecting onset of neurological dysfunction in anesthetized patients, thereby precisely defining time last electrically well (LEW). This novel parameter may aid in the detection of large vessel occlusion (LVO) and prompt treatment with endovascular thrombectomy (EVT). METHODS: We performed a retrospective analysis of a prospectively maintained AIS and LVO database from May 2018-August 2019. Inclusion criteria required any surgical procedure under general anesthesia (GA) utilizing EEG (electroencephalography) and/or SSEP (somatosensory evoked potentials) monitoring with development of intraoperative focal persistent changes using predefined alarm criteria and who were considered for EVT. RESULT: Five cases were identified. LKW to closure time ranged from 66 to 321 minutes, while LEW to closure time ranged from 43 to 174 min. All LVOs were in the anterior circulation. Angiography was not pursued in two cases due to large established infarct (both patients expired in the hospital). EVT was pursued in two cases with successful recanalization and spontaneous recanalization was noted in one patient (mRS 0-3 at 90 days was achieved in all 3 cases). CONCLUSIONS: This study demonstrates that significant IONM changes can accurately identify patients with an acute LVO in the operative setting. Given the challenges of recognizing peri-operative stroke, LEW may be an appropriate surrogate to quickly identify and treat IOS.
Assuntos
Eletroencefalografia , Procedimentos Endovasculares , Potenciais Somatossensoriais Evocados , Monitorização Neurofisiológica Intraoperatória , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/terapia , Triagem , Idoso , Anestesia Geral , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/mortalidade , Feminino , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Resultado do TratamentoRESUMO
Basal ganglia-thalamocortical loops mediate all motor behavior, yet little detail is known about the role of basal ganglia nuclei in speech production. Using intracranial recording during deep brain stimulation surgery in humans with Parkinson's disease, we tested the hypothesis that the firing rate of subthalamic nucleus neurons is modulated in sync with motor execution aspects of speech. Nearly half of 79 unit recordings exhibited firing-rate modulation during a syllable reading task across 12 subjects (male and female). Trial-to-trial timing of changes in subthalamic neuronal activity, relative to cue onset versus production onset, revealed that locking to cue presentation was associated more with units that decreased firing rate, whereas locking to speech onset was associated more with units that increased firing rate. These unique data indicate that subthalamic activity is dynamic during the production of speech, reflecting temporally-dependent inhibition and excitation of separate populations of subthalamic neurons.SIGNIFICANCE STATEMENT The basal ganglia are widely assumed to participate in speech production, yet no prior studies have reported detailed examination of speech-related activity in basal ganglia nuclei. Using microelectrode recordings from the subthalamic nucleus during a single-syllable reading task, in awake humans undergoing deep brain stimulation implantation surgery, we show that the firing rate of subthalamic nucleus neurons is modulated in response to motor execution aspects of speech. These results are the first to establish a role for subthalamic nucleus neurons in encoding of aspects of speech production, and they lay the groundwork for launching a modern subfield to explore basal ganglia function in human speech.
Assuntos
Neurônios/fisiologia , Fala/fisiologia , Núcleo Subtalâmico/fisiologia , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-IdadeRESUMO
The goal of this study was to evaluate the risk factors associated with positioning-related SSEP changes (PRSC). The study investigated the association between 18 plausible risk factors and the occurrence of intraoperative PRSC. Risk factors investigated included demographic variables, comorbidities, and procedure related variables. All patients were treated by the University of Pittsburgh Medical Center from 2010 to 2012. We used univariate and multivariate statistical methods. 69 out of the 3946 (1.75%) spinal surgeries resulted in PRSC changes. The risk of PRSC was increased for women (p < 0.001), patients older than 65 years of age (p = 0.01), higher BMI (p < 0.001) patients, smokers (p < 0.001), and patients with hypertension (p < 0.001). No associations were found between PRSC and age greater than 80 years, diabetes mellitus, cardiovascular disease, and peripheral vascular disease. Three surgical situations were associated with PRSC including abnormal baselines (p < 0.001), patients in the "superman" position (p < 0.001), and patients in surgical procedures that extended over 200 min (p = 0.03). Patients with higher BMIs and who are undergoing spinal surgery longer than 200 min, with abnormal baselines, must be positioned with meticulous attention. Gender, hypertension, and smoking were also found to be risk factors from their odds ratios.
Assuntos
Potenciais Somatossensoriais Evocados , Monitorização Intraoperatória/métodos , Coluna Vertebral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Feminino , Monitorização Hemodinâmica , Humanos , Período Intraoperatório , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Procedimentos Neurocirúrgicos , Estudos Retrospectivos , Fatores de RiscoRESUMO
Coupled oscillatory activity recorded between sensorimotor regions of the basal ganglia-thalamocortical loop is thought to reflect information transfer relevant to movement. A neuronal firing-rate model of basal ganglia-thalamocortical circuitry, however, has dominated thinking about basal ganglia function for the past three decades, without knowledge of the relationship between basal ganglia single neuron firing and cortical population activity during movement itself. We recorded activity from 34 subthalamic nucleus (STN) neurons, simultaneously with cortical local field potentials and motor output, in 11 subjects with Parkinson's disease (PD) undergoing awake deep brain stimulator lead placement. STN firing demonstrated phase synchronization to both low- and high-beta-frequency cortical oscillations, and to the amplitude envelope of gamma oscillations, in motor cortex. We found that during movement, the magnitude of this synchronization was dynamically modulated in a phase-frequency-specific manner. Importantly, we found that phase synchronization was not correlated with changes in neuronal firing rate. Furthermore, we found that these relationships were not exclusive to motor cortex, because STN firing also demonstrated phase synchronization to both premotor and sensory cortex. The data indicate that models of basal ganglia function ultimately will need to account for the activity of populations of STN neurons that are bound in distinct functional networks with both motor and sensory cortices and code for movement parameters independent of changes in firing rate.NEW & NOTEWORTHY Current models of basal ganglia-thalamocortical networks do not adequately explain simple motor functions, let alone dysfunction in movement disorders. Our findings provide data that inform models of human basal ganglia function by demonstrating how movement is encoded by networks of subthalamic nucleus (STN) neurons via dynamic phase synchronization with cortex. The data also demonstrate, for the first time in humans, a mechanism through which the premotor and sensory cortices are functionally connected to the STN.
Assuntos
Movimento , Neurônios/fisiologia , Córtex Sensório-Motor/fisiologia , Núcleo Subtalâmico/fisiologia , Idoso , Ritmo beta , Sincronização Cortical , Feminino , Ritmo Gama , Humanos , Masculino , Pessoa de Meia-Idade , Córtex Sensório-Motor/citologia , Núcleo Subtalâmico/citologiaRESUMO
Recent electrocorticography data have demonstrated excessive coupling of beta-phase to gamma-amplitude in primary motor cortex and that deep brain stimulation facilitates motor improvement by decreasing baseline phase-amplitude coupling. However, both the dynamic modulation of phase-amplitude coupling during movement and the general cortical neurophysiology of other movement disorders, such as essential tremor, are relatively unexplored. To clarify the relationship of these interactions in cortical oscillatory activity to movement and disease state, we recorded local field potentials from hand sensorimotor cortex using subdural electrocorticography during a visually cued, incentivized handgrip task in subjects with Parkinson's disease (n = 11), with essential tremor (n = 9) and without a movement disorder (n = 6). We demonstrate that abnormal coupling of the phase of low frequency oscillations to the amplitude of gamma oscillations is not specific to Parkinson's disease, but also occurs in essential tremor, most prominently for the coupling of alpha to gamma oscillations. Movement kinematics were not significantly different between these groups, allowing us to show for the first time that robust alpha and beta desynchronization is a shared feature of sensorimotor cortical activity in Parkinson's disease and essential tremor, with the greatest high-beta desynchronization occurring in Parkinson's disease and the greatest alpha desynchronization occurring in essential tremor. We also show that the spatial extent of cortical phase-amplitude decoupling during movement is much greater in subjects with Parkinson's disease and essential tremor than in subjects without a movement disorder. These findings suggest that subjects with Parkinson's disease and essential tremor can produce movements that are kinematically similar to those of subjects without a movement disorder by reducing excess sensorimotor cortical phase-amplitude coupling that is characteristic of these diseases.
Assuntos
Ondas Encefálicas/fisiologia , Eletrocorticografia/métodos , Sincronização de Fases em Eletroencefalografia/fisiologia , Tremor Essencial/fisiopatologia , Atividade Motora/fisiologia , Doença de Parkinson/fisiopatologia , Desempenho Psicomotor/fisiologia , Córtex Sensório-Motor/fisiopatologia , Adulto , Idoso , Fenômenos Biomecânicos , Feminino , Mãos , Humanos , Masculino , Pessoa de Meia-Idade , Córtex Motor/fisiopatologia , Adulto JovemRESUMO
OBJECTIVES: To evaluate the efficacy of intraoperative transcranial Doppler monitoring in predicting perioperative strokes after carotid endarterectomy (CEA). METHODS: An electronic search of PubMed, Embase, and Web of Science databases was conducted for studies on transcranial Doppler monitoring in CEA published from January 1970 through September 2015. All titles and abstracts were independently screened on the basis of predetermined inclusion criteria, which included randomized clinical trials and prospective or retrospective cohort reviews, patients who underwent CEA with intraoperative transcranial Doppler monitoring (either middle cerebral artery velocity [MCAV] or cerebral microembolic signals [MES]) and postoperative neurologic assessments up to 30 days after the surgery, and studies including an abstract, published in English on adult humans 18 years and older with a sample size of 50 or greater. RESULTS: A total of 25articles with a sample population of 4705 patients were analyzed. Among the study patients, 189 developed perioperative strokes. Transcranial Doppler monitoring (either MCAV or MES) showed specificity of 72.7% (95% confidence interval [CI], 61.2%-81.8%) and sensitivity of 56.1% (95% CI, 46.8%-65.0%) for predicting perioperative strokes. Intraoperative MCAV changes during CEA showed strong specificity of 84.1% (95% CI, 74.4%-90.6) and sensitivity of 49.7% (95% CI, 40.6%-58.8) for predicting perioperative strokes. CONCLUSIONS: Patients with perioperative strokes are 4 times more likely to have had transcranial Doppler changes (either MCAV or MES) during CEA compared to patients without strokes. Simultaneous MCAV and MES monitoring by transcranial Doppler sonography and combined intraoperative monitoring of transcranial Doppler sonography with somatosensory evoked potentials and electroencephalography during CEA to predict perioperative stroke could not be evaluated because of a lack of clinical studies combining these measures.
Assuntos
Artérias Carótidas/diagnóstico por imagem , Artérias Carótidas/cirurgia , Endarterectomia das Carótidas/métodos , Cuidados Intraoperatórios/métodos , Acidente Vascular Cerebral/diagnóstico por imagem , Ultrassonografia Doppler Transcraniana/métodos , Endarterectomia das Carótidas/efeitos adversos , HumanosRESUMO
OBJECTIVE: To evaluate three commonly used alarm criteria for interpreting the significance and diagnostic value of transcranial motor evoked potential (TcMEP) changes during spinal surgery. MATERIALS AND METHODS: A systematic literature search was performed using PubMed/MEDLINE, Web of Science, and EMBASE from 1945 to January 2014. We included all those studies that were (1) randomized controlled trials, prospective studies, or retrospective cohort studies, (2) conducted among patients undergoing surgery on the spine or spinal cord with TcMEP monitoring, (3) conducted in a group of ≥50 patients, (4) that were inclusive of immediate postoperative neurological assessment (within 24 h), and (5) which were published in English. RESULTS: Twenty-five studies involving 9409 patients were included. The incidence of neurological deficits was 1.82%. The overall sensitivity and specificity of all reported TcMEP changes was 82.1% (95% confidence interval [CI]: 73-88.6%) and 95.7% (95% CI: 93.7-97.1%), respectively. The sensitivity and specificity of each alarm criteria were evaluated: 50% reduction in amplitude, sensitivity 63.2% (95% CI: 47-76.8%), and specificity 96.7% (95% CI: 96.4-99.2%); 80% reduction in amplitude, sensitivity 71.7% (95% CI; 42-89.9%), and specificity 98.3% (95% CI: 96.4-99.2%); total signal loss, sensitivity 30% (95% CI: 17.6-46.4%), and specificity 99.3% (95% CI: 98.6-99.7%). CONCLUSIONS: No statistically significant differences between using reductions in amplitude of 50% and 80% as alarm criteria were found in terms of sensitivity and specificity. Total loss was found to have a statistically significant increase in specificity. TcMEP monitoring is a highly specific and sensitive diagnostic tool for the detection of neurological defects during spinal surgery.
Assuntos
Potencial Evocado Motor , Monitorização Neurofisiológica Intraoperatória/métodos , Procedimentos Neurocirúrgicos/efeitos adversos , Traumatismos da Medula Espinal/diagnóstico , Traumatismos da Medula Espinal/etiologia , Humanos , Doença Iatrogênica/prevenção & controle , Sensibilidade e Especificidade , Estimulação Transcraniana por Corrente Contínua/métodosRESUMO
Electrophysiological recordings from subdural electrocorticography (ECoG) electrodes implanted temporarily during deep brain stimulation (DBS) surgeries offer a unique opportunity to record cortical activity for research purposes. The optimal utilization of this important research method relies on accurate and robust localization of ECoG electrodes, and intraoperative fluoroscopy is often the only imaging modality available to visualize electrode locations. However, the localization of a three-dimensional electrode position using a two-dimensional fluoroscopic image is problematic due to the lost dimension orthogonal to the fluoroscopic image, a parallax distortion implicit to fluoroscopy, and variability of visible skull contour among fluoroscopic images. Here, we present a method to project electrodes visible on the fluoroscopic image onto a reconstructed cortical surface by leveraging numerous common landmarks to translate, rotate, and scale coregistered computed tomography (CT) and magnetic resonance imaging (MRI) reconstructed surfaces in order to recreate the coordinate framework in which the fluoroscopic image was acquired, while accounting for parallax distortion. Validation of this approach demonstrated high precision with an average total Euclidian distance between three independent reviewers of 1.65±0.68mm across 8 patients and 82 electrodes. Spatial accuracy was confirmed by correspondence between recorded neural activity over sensorimotor cortex during hand movement. This semi-automated interface reliably estimates the location of temporarily implanted subdural ECoG electrodes visible on intraoperative fluoroscopy to a cortical surface.
Assuntos
Mapeamento Encefálico/métodos , Estimulação Encefálica Profunda/métodos , Processamento de Imagem Assistida por Computador/métodos , Imageamento Tridimensional/métodos , Transtornos dos Movimentos/terapia , Idoso , Eletrocorticografia/métodos , Eletrodos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Imagem Multimodal , Neuronavegação/métodos , SoftwareRESUMO
BACKGROUND: Carotid endarterectomy (CEA) is the procedure of choice for reducing the risk of stroke in both symptomatic and asymptomatic carotid artery stenoses. Stroke is associated with significant morbidity and mortality peri-operatively (2-3 %). Our primary aim is to evaluate the etiology of these strokes after CEA and their impact on morbidity by comparing the length of stay in the hospital. METHODS: A total of 584 patients with documented neurological status evaluations who underwent CEAs were included in the study. Neurophysiological monitoring data was obtained during CEA for carotid stenosis included eight-channel electroencephalography (EEG) and upper extremity somatosensory evoked potentials (SSEPs). RESULTS: Twenty-one (3.595 %) patients had strokes in the perioperative period and they were more likely to have left-sided surgery (p = 0.008), intraoperative monitoring (IOM) changes (p < 0.001), an intraoperative shunt placed (p = 0.0002) or a hospital stay longer than 5 days (p = 0.0042). Unilateral anterior circulation ischemic stroke were the most common in our series. In a logistic regression model, left-sided surgery was shown to be 4.78 times more likely to be associated with perioperative stroke (1.50-15.27; p = 0.008) while intraoperative shunts were 11.85 times more likely to have strokes (3.97-35.34; p < 0.0001). Patients with stenosis greater than 70 % were 6.67 times less likely to have a stroke (0.04-0.59; p = 0.007). CONCLUSIONS: Ischemic anterior circulation strokes are the most common type of post-operative neurological changes in patients undergoing CEA. Intraoperative shunt placement was a strong predictor of perioperative strokes. Since shunts are only placed following intraoperative monitoring changes, SSEPs and EEG can therefore function as a biomarker of cerebral hypo-perfusion.
Assuntos
Estenose das Carótidas/cirurgia , Endarterectomia das Carótidas/efeitos adversos , Complicações Pós-Operatórias/etiologia , Acidente Vascular Cerebral/etiologia , Idoso , Eletroencefalografia , Potenciais Somatossensoriais Evocados , Feminino , Humanos , Monitorização Neurofisiológica Intraoperatória , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/prevenção & controle , Acidente Vascular Cerebral/prevenção & controleRESUMO
OBJECTIVE: To determine the utility of electroencephalography (EEG) in predicting postoperative delirium (POD) in patients who underwent cardiovascular surgeries with EEG monitoring. METHODS: A total of 1161 patients who underwent cardiovascular surgeries with EEG monitoring were included in the study, and their data were retrospectively reviewed. POD assessment was done utilizing Intensive Care Delirium Screening Checklist (ICDSC). Patients with a score of > 4 on ICDSC were diagnosed with POD. RESULTS: Of 1161 patients, 131 patients had EEG changes and 56 (42.74%) of 131 patients experienced POD. Of 1030 patients without EEG changes, 219 (21.26%) experienced POD. EEG showed specificity of 91.5% and negative predictive value of 78.7% in detecting POD. On multivariable analysis, EEG changes showed a strong association with POD (ORadj 1.97 CI (1.30-2.99), p = 0.001) with persistent EEG changes showing even a higher risk of developing POD (ORadj 2.65 (1.43-4.92), p = 0.002). CONCLUSION: EEG change has specificity of 91.5% emphasizing the need for its implementation as a diagnostic tool for predicting POD. Patients with POD are two times more likely to experience significant EEG changes, especially persistent EEG changes when undergoing cardiovascular surgeries. SIGNIFICANCE: Intraoperative EEG can detect POD, and EEG changes based therapeutic interventions can mitigate POD.
Assuntos
Delírio , Eletroencefalografia , Humanos , Masculino , Feminino , Eletroencefalografia/métodos , Pessoa de Meia-Idade , Idoso , Estudos Retrospectivos , Delírio/diagnóstico , Delírio/fisiopatologia , Delírio/etiologia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/etiologia , Procedimentos Cirúrgicos Cardiovasculares/efeitos adversos , Monitorização Neurofisiológica Intraoperatória/métodos , Valor Preditivo dos Testes , AdultoRESUMO
OBJECTIVE: Recovery of abducens nerve palsy (ANP) after endoscopic endonasal skull base surgery (ESBS) has been shown to be potentially predicted by postoperative ophthalmological examination. Triggered electromyography (t-EMG) and free-run electromyography (f-EMG) activity provide an intraoperative assessment of abducens nerve function, but associations with long-term ANP outcomes have not been explored. The objective of this study was to describe intraoperative abducens EMG characteristics and determine whether these electrophysiological profiles are associated with immediately postoperative and long-term ANP outcomes after ESBS. METHODS: The authors conducted a 5-year (2011-2016) retrospective case-control study of patients who underwent ESBS in whom the abducens nerve was stimulated (t-EMG). Electrophysiological metrics were compared between patients with a new postoperative ANP (cases) and those without ANP (controls). Pathologies included chordoma, pituitary adenoma, meningioma, cholesterol granuloma, and chondrosarcoma. Electrophysiological data included the presence of abnormal f-EMG activity, t-EMG stimulation voltage, stimulation threshold, evoked compound muscle action potential (CMAP) amplitude, onset latency, peak latency, and CMAP duration at various stages of the dissection. Controls were selected such that pathologies were similarly distributed between cases and controls. RESULTS: Fifty-six patients were included, 26 with new postoperative ANP and 30 controls without ANP. Abnormal f-EMG activity (28.0% vs 3.3%, p = 0.02) and lack of response to stimulation (27% vs 0%, p = 0.006) were more frequent in patients with immediately postoperative ANP than in controls. Patients with immediately postoperative ANP also had a lower median CMAP amplitude (35.0 vs 71.2 µV, p = 0.02) and longer onset latency (5.2 vs 2.8 msec, p = 0.04). Comparing patients with transient versus persistent ANP on follow-up, those with persistent ANP tended to have a lower CMAP amplitude (12.8 vs 57 µV, p = 0.07) and higher likelihood of not responding to stimulation at the end of the case (45.5% vs 7.1%, p = 0.06). Abnormal f-EMG was not associated with long-term ANP outcomes. CONCLUSIONS: The presence of f-EMG activity, lack of CMAP response to stimulation, decreased CMAP amplitude, and increased CMAP onset latency were associated with immediately postoperative ANP. Long-term ANP outcomes may be associated with t-EMG parameters, including whether the nerve is able to be stimulated once identified and CMAP amplitude. Future prospective studies may be designed to standardize abducens nerve electrophysiological monitoring protocols to further refine operative and prognostic utility.
Assuntos
Doenças do Nervo Abducente , Eletromiografia , Complicações Pós-Operatórias , Base do Crânio , Humanos , Estudos Retrospectivos , Masculino , Doenças do Nervo Abducente/etiologia , Doenças do Nervo Abducente/fisiopatologia , Feminino , Pessoa de Meia-Idade , Estudos de Casos e Controles , Adulto , Idoso , Base do Crânio/cirurgia , Complicações Pós-Operatórias/etiologia , Neoplasias da Base do Crânio/cirurgiaRESUMO
OBJECTIVE: To evaluate the diagnostic accuracy of intraoperative neurophysiological monitoring (IONM) during endovascular treatment (EVT) of ruptured intracranial aneurysms (rIA). METHODS: IONM and clinical data from 323 patients who underwent EVT for rIA from 2014-2019 were retrospectively reviewed. Significant IONM changes and outcomes were evaluated based on visual review of data and clinical documentation. RESULTS: Of the 323 patients undergoing EVT, significant IONM changes were noted in 30 patients (9.29%) and 46 (14.24%) experienced postprocedural neurological deficits (PPND). 22 out of 30 (73.33%) patients who had significant IONM changes experienced PPND. Univariable analysis showed changes in somatosensory evoked potential (SSEP) and electroencephalogram (EEG) were associated with PPND (p-values: <0.001 and <0.001, retrospectively). Multivariable analysis showed that IONM changes were significantly associated with PPND (Odd ratio (OR) 20.18 (95%CI:7.40-55.03, p-value: <0.001)). Simultaneous changes in both IONM modalities had specificity of 98.9% (95% CI: 97.1%-99.7%). While sensitivity when either modality had a change was 47.8% (95% CI: 33.9%-62.0%) to predict PPND. CONCLUSIONS: Significant IONM changes during EVT for rIA are associated with an increased risk of PPND. SIGNIFICANCE: IONM can be used confidently as a real time neurophysiological diagnostic guide for impending neurological deficits during EVT treatment of rIA.
Assuntos
Aneurisma Roto , Isquemia Encefálica , Eletroencefalografia , Procedimentos Endovasculares , Potenciais Somatossensoriais Evocados , Aneurisma Intracraniano , Monitorização Neurofisiológica Intraoperatória , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Procedimentos Endovasculares/efeitos adversos , Procedimentos Endovasculares/métodos , Aneurisma Roto/cirurgia , Aneurisma Roto/fisiopatologia , Aneurisma Intracraniano/cirurgia , Aneurisma Intracraniano/fisiopatologia , Monitorização Neurofisiológica Intraoperatória/métodos , Isquemia Encefálica/diagnóstico , Isquemia Encefálica/fisiopatologia , Estudos Retrospectivos , Potenciais Somatossensoriais Evocados/fisiologia , Idoso , Adulto , Eletroencefalografia/métodosRESUMO
Cerebral white matter lesions prevent cortico-spinal descending inputs from effectively activating spinal motoneurons, leading to loss of motor control. However, in most cases, the damage to cortico-spinal axons is incomplete offering a potential target for therapies aimed at improving volitional muscle activation. Here we hypothesize that, by engaging direct excitatory connections to cortico-spinal motoneurons, stimulation of the motor thalamus could facilitate activation of surviving cortico-spinal fibers thereby immediately potentiating motor output. To test this hypothesis, we identify optimal thalamic targets and stimulation parameters that enhance upper-limb motor-evoked potentials and grip forces in anesthetized monkeys. This potentiation persists after white matter lesions. We replicate these results in humans during intra-operative testing. We then design a stimulation protocol that immediately improves strength and force control in a patient with a chronic white matter lesion. Our results show that electrical stimulation targeting surviving neural pathways can improve motor control after white matter lesions.
Assuntos
Estimulação Elétrica , Potencial Evocado Motor , Córtex Motor , Neurônios Motores , Tálamo , Animais , Tálamo/fisiologia , Córtex Motor/fisiologia , Humanos , Potencial Evocado Motor/fisiologia , Masculino , Neurônios Motores/fisiologia , Estimulação Elétrica/métodos , Macaca mulatta , Feminino , Força da Mão/fisiologia , Substância Branca/fisiologia , Substância Branca/fisiopatologia , Medula Espinal/fisiologiaRESUMO
OBJECT: Microvascular decompression (MVD) of the facial nerve is an effective treatment for patients with hemifacial spasm. Intraoperative monitoring of brainstem auditory evoked potentials (BAEPs) during MVD can reduce the incidence of hearing loss. In this study the authors' goal was to evaluate changes in interpeak latencies (IPLs) of Waves I-V, Waves III-V, and Waves I-III of BAEP Waveforms I, III, and V during MVD and correlate them with postoperative hearing loss. To date, no such study has been performed. Hearing loss is defined as nonuseful hearing (Class C/D), which is a pure tone average of more than 50 dB and/or speech discrimination score of less than 50%. METHODS: The authors performed a retrospective analysis of IPLs of BAEPs in 93 patients who underwent intraoperative BAEP monitoring during MVD. Patients who did not have hearing loss were in Class A/B and those who had hearing loss were in Class C/D. RESULTS: Binary logistic regression analysis of independent IPL variables was performed. A maximum change in IPLs of Waves I-III and Waves I-V and on-skin change in IPLs of Waves I-V increases the odds of hearing loss. However, on adjusting the same variables for loss of response, change in IPLs did not increase the odds of hearing loss. CONCLUSIONS: Changes in IPL measurements did not increase the odds of postoperative hearing loss. This information might be helpful in evaluating the value of IPLs as alarm criteria during MVD to prevent hearing loss.