Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 140
Filtrar
1.
Nano Lett ; 24(4): 1145-1152, 2024 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-38194429

RESUMO

We present a novel technique of genetic transformation of bacterial cells mediated by high frequency electromagnetic energy (HF EME). Plasmid DNA, pGLO (5.4 kb), was successfully transformed into Escherichia coli JM109 cells after exposure to 18 GHz irradiation at a power density between 5.6 and 30 kW m-2 for 180 s at temperatures ranging from 30 to 40 °C. Transformed bacteria were identified by the expression of green fluorescent protein (GFP) using confocal scanning microscopy (CLSM) and flow cytometry (FC). Approximately 90.7% of HF EME treated viable E. coli cells exhibited uptake of the pGLO plasmid. The interaction of plasmid DNA with bacteria leading to transformation was confirmed by using cryogenic transmission electron microscopy (cryo-TEM). HF EME-induced plasmid DNA transformation was shown to be unique, highly efficient, and cost-effective. HF EME-induced genetic transformation is performed under physiologically friendly conditions in contrast to existing techniques that generate higher temperatures, leading to altered cellular integrity. This technique allows safe delivery of genetic material into bacterial cells, thus providing excellent prospects for applications in microbiome therapeutics and synthetic biology.


Assuntos
Escherichia coli , Transformação Bacteriana , Plasmídeos/genética , DNA/metabolismo , Bactérias/genética , Radiação Eletromagnética
2.
Bioelectromagnetics ; 45(4): 200-205, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38348555

RESUMO

A crucial aspect of IARC's evaluation of the relative carcinogenicity of agents is the communication of its conclusions. The present paper addressed the experimental risk perception literature pertaining to IARC's radiofrequency electromagnetic field evaluation communication, and derived specific recommendations for improving it.


Assuntos
Campos Eletromagnéticos , Neoplasias , Humanos , Campos Eletromagnéticos/efeitos adversos , Neoplasias/etiologia , Ondas de Rádio/efeitos adversos , Comunicação
3.
J Synchrotron Radiat ; 30(Pt 4): 780-787, 2023 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-37338043

RESUMO

The routes by which foreign objects enter cells is well studied; however, their fate following uptake has not been explored extensively. Following exposure to synchrotron-sourced (SS) terahertz (THz) radiation, reversible membrane permeability has been demonstrated in eukaryotic cells by the uptake of nanospheres; nonetheless, cellular localization of the nanospheres remained unclear. This study utilized silica core-shell gold nanospheres (AuSi NS) of diameter 50 ± 5 nm to investigate the fate of nanospheres inside pheochromocytoma (PC 12) cells following SS THz exposure. Fluorescence microscopy was used to confirm nanosphere internalization following 10 min of SS THz exposure in the range 0.5-20 THz. Transmission electron microscopy followed by scanning transmission electron microscopy energy-dispersive spectroscopic (STEM-EDS) analysis was used to confirm the presence of AuSi NS in the cytoplasm or membrane, as single NS or in clusters (22% and 52%, respectively), with the remainder (26%) sequestered in vacuoles. Cellular uptake of NS in response to SS THz radiation could have suitable applications in a vast number of biomedical applications, regenerative medicine, vaccines, cancer therapy, gene and drug delivery.


Assuntos
Neoplasias das Glândulas Suprarrenais , Nanosferas , Feocromocitoma , Humanos , Radiação Terahertz , Nanosferas/química , Síncrotrons
4.
Bioelectromagnetics ; 42(2): 146-158, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33440463

RESUMO

It is generally believed that the phosphenes induced by transcranial electric current stimulation (tECS) are a product of retinal activation, even when electrode placement is directly over the primary visual cortex. However, the origins of these tECS-induced phosphenes have not yet been conclusively determined. In this study, phosphene detection thresholds using an FPz-Oz montage were compared with those from (i) an Oz-Cz montage to determine whether prefrontal regions, such as the retina, contribute to phosphenes and (ii) an FPz-Cz montage to determine whether the visual cortex in the occipital lobe contributes to phosphenes. Twenty-two participants received transcranial current stimulation with each of these montages (as well as a T3-T4 montage included for exploratory purposes) at 6, 10, 16, 20, 24, 28, and 32 Hz. To estimate differences in current density at the retina and occipital lobe across montages, modeling of current density at phosphene thresholds was measured across 20 head models. Consistent with the proposal that tECS-induced phosphenes are generated in the retina, increasing current density near the retina (FPz-Oz relative to Oz-Cz montage) reduced phosphene thresholds. However, increasing current density near the occipital cortex (FPz-Oz relative to FPz-Cz montage) also reduced phosphene thresholds while also requiring less current density at the retina according to the modeling estimates. This suggests that tECS of this occipital cortex also contributed to phosphene perception. © 2020 Bioelectromagnetics Society.


Assuntos
Fosfenos , Retina/fisiologia , Estimulação Transcraniana por Corrente Contínua , Córtex Visual/fisiologia , Adulto , Feminino , Humanos , Masculino
5.
Bioelectromagnetics ; 42(4): 317-328, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33847008

RESUMO

Although there is consistent evidence that exposure to radiofrequency electromagnetic fields (RF-EMF) increases the spontaneous resting alpha spectral power of the electroencephalogram (EEG), the reliability of this evidence is uncertain as some studies have also failed to observe this effect. The present study aimed to determine whether the effect of RF-EMF exposure on EEG alpha power depends on whether EEG is derived from eyes open or closed conditions and assessed earlier (<5-min) versus later (>25-min) in the exposure interval. Thirty-six adults participated in three experimental sessions, each involving one exposure: "Sham," "Low," and "High" RF-EMF corresponding to peak spatial specific absorption rates averaged over 10 g of 0, 1, and 2 W/kg, respectively. Resting EEG was recorded at baseline (no exposure), during, and after exposure. Alpha power increase was found to be greater for the eyes open than eyes closed EEG during both the High (P = 0.04) and Low (P = 0.04) RF-EMF exposures. There was also a trend toward it being larger at the end, versus the start of the "High" 30-min exposure (P < 0.01; eyes open condition). This suggests that the use of eyes closed conditions, and insufficient RF-EMF exposure durations, are likely explanations for the failure of some studies to detect an RF-EMF exposure-related increase in alpha power, as such methodological choices decrease signal-to-noise ratios and increase type II error.


Assuntos
Campos Eletromagnéticos , Ondas de Rádio , Adulto , Eletroencefalografia , Campos Eletromagnéticos/efeitos adversos , Humanos , Ondas de Rádio/efeitos adversos , Reprodutibilidade dos Testes , Descanso
6.
Eur J Appl Physiol ; 120(12): 2797-2811, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32986163

RESUMO

PURPOSE: Whole-body thermal and hydration clamps were used to evaluate their independent and combined impact on the electrical activity of the brain. It was hypothesised that those stresses would independently modify the electroencephalographic (EEG) responses, with those changes being greater when both stresses were superimposed. METHODS: Alpha and beta spectral data (eyes closed) were collected from the frontal, central-parietal and occipital cortices of both hemispheres in resting, healthy and habitually active males (N = 8; mean age 25 years). Three dehydration states were investigated (euhydrated and 3% and 5% mass decrements) in each of two thermal states (normothermia [mean body temperature 36.3 °C] and moderate hyperthermia [38.4 °C]). The combination of those passively induced states yielded six levels of physiological strain, with the EEG data from each level separately examined using repeated-measures ANOVA with planned contrasts. RESULTS: When averaged across the frontal cortices, alpha power was elevated relative to the occipital cortices during moderate hyperthermia (P = 0.049). Conversely, beta power was generally reduced during hyperthermia (P = 0.013). Neither the alpha nor beta power spectra responded to dehydration, nor did dehydration elevate the heat-induced responses (P > 0.05). CONCLUSION: Moderate hyperthermia, but neither mild nor moderate dehydration, appeared to independently alter brain electrical activity. Moreover, the combination of moderate hyperthermia with 5% dehydration did not further increase those changes. That outcome was interpreted to mean that, when those states were superimposed, the resulting neurophysiological changes could almost exclusively be attributed to the thermal impact per se, rather than to their combined influences.


Assuntos
Encéfalo/fisiopatologia , Desidratação/fisiopatologia , Hipertermia/fisiopatologia , Adulto , Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Exercício Físico/fisiologia , Febre/fisiopatologia , Frequência Cardíaca/fisiologia , Humanos , Masculino
7.
Eur J Appl Physiol ; 120(12): 2813-2834, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-32986164

RESUMO

PURPOSE: This experiment was designed to quantify the independent and combined influences of hyperthermia and dehydration on effector control during rest and exercise. METHODS: To achieve that, whole-body hydration of healthy adults (N = 8) was manipulated into each of three states (euhydrated, 3% and 5% dehydrated), and then clamped within each of two thermal states (normothermia [mean body temperature: 36.1 °C] and moderate hyperthermia [mean body temperature: 38.2 °C]). Those treatment combinations provided six levels of physiological strain, with resting physiological data collected at each level. The effects of isothermal, thermally unclamped and incremental exercise were then investigated in normothermic individuals during each level of hydration. RESULTS: At rest, dehydration alone reduced urine flows by 83% (3% dehydrated) and 93% (5% dehydrated), while the reduction accompanying euhydrated hyperthermia was 86%. The sensitivities of renal water conservation to 3% dehydration (-21% mOsm-1 kg H2O-1) and moderate hyperthermia (-40% °C-1) were independent and powerful. Evidence was found for different renal mechanisms governing water conservation between those treatments. Cutaneous vasomotor and central cardiac responses were unresponsive to dehydration, but highly sensitive to passive thermal stress. Dehydration did not impair either whole-body or regional sweating during rest or exercise, and not even during incremental cycling to volitional exhaustion. CONCLUSION: In all instances, the physiological impact of these thermal- and hydration-state stresses was independently expressed, with no evidence of interactive influences. Renal water-conservation was independently and powerfully modified, exposing possible between-treatment differences in sodium reabsorption.


Assuntos
Desidratação/fisiopatologia , Exercício Físico/fisiologia , Hipertermia/fisiopatologia , Descanso/fisiologia , Adulto , Pressão Sanguínea/fisiologia , Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Febre/fisiopatologia , Temperatura Alta , Humanos , Masculino , Pele/fisiopatologia , Sudorese/fisiologia
8.
Eur Arch Psychiatry Clin Neurosci ; 269(1): 17-35, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30661105

RESUMO

Access to cannabis and cannabinoid products is increasing worldwide for recreational and medicinal use. Two primary compounds within cannabis plant matter, Δ9-tetrahydrocannabinol (THC) and cannabidiol (CBD), are both psychoactive, but only THC is considered intoxicating. There is significant interest in potential therapeutic properties of these cannabinoids and of CBD in particular. Some research has suggested that CBD may ameliorate adverse effects of THC, but this may be dose dependent as other evidence suggests possible potentiating effects of THC by low doses of CBD. We conducted a randomised placebo controlled trial to examine the acute effects of these compounds alone and in combination when administered by vaporisation to frequent and infrequent cannabis users. Participants (n = 36; 31 male) completed 5 drug conditions spaced one week apart, with the following planned contrasts: placebo vs CBD alone (400 mg); THC alone (8 mg) vs THC combined with low (4 mg) or high (400 mg) doses of CBD. Objective (blind observer ratings) and subjective (self-rated) measures of intoxication were the primary outcomes, with additional indices of intoxication examined. CBD showed some intoxicating properties relative to placebo. Low doses of CBD when combined with THC enhanced, while high doses of CBD reduced the intoxicating effects of THC. The enhancement of intoxication by low-dose CBD was particularly prominent in infrequent cannabis users and was consistent across objective and subjective measures. Most effects were significant at p < .0001. These findings are important to consider in terms of recommended proportions of THC and CBD in cannabis plant matter whether used medicinally or recreationally and have implications for novice or less experienced cannabis users.Trial registration: ISRCTN Registry Identifier: ISRCTN24109245.


Assuntos
Canabidiol/farmacologia , Moduladores de Receptores de Canabinoides/farmacologia , Cannabis , Transtornos Dissociativos/induzido quimicamente , Dronabinol/farmacologia , Efeitos Colaterais e Reações Adversas Relacionados a Medicamentos , Transtornos da Percepção/induzido quimicamente , Adolescente , Adulto , Pressão Sanguínea/efeitos dos fármacos , Canabidiol/administração & dosagem , Canabidiol/efeitos adversos , Moduladores de Receptores de Canabinoides/administração & dosagem , Moduladores de Receptores de Canabinoides/efeitos adversos , Dronabinol/administração & dosagem , Interações Medicamentosas , Feminino , Frequência Cardíaca/efeitos dos fármacos , Humanos , Masculino , Pessoa de Meia-Idade , Autorrelato , Adulto Jovem
9.
Environ Res ; 170: 493-499, 2019 03.
Artigo em Inglês | MEDLINE | ID: mdl-30690250

RESUMO

BACKGROUND: Exposure to far-field radiofrequency electromagnetic fields (RF-EMF) has raised public concerns in recent decades. However, it is not known if individuals' perception towards the health risks of RF-EMF is dependent on their knowledge of the objectively measured personal RF-EMF exposure levels. OBJECTIVES: This pilot study aimed to demonstrate the feasibility of objectively measuring personal RF-EMF exposure from mobile phone base stations (MPBS) and to determine if the risk perception of people to the potential health risk of exposure to RF-EMF from MPBS is dependent on their knowledge of personal RF-EMF exposure levels. DESIGN: An experimental study was conducted in 383 adults, recruited in Melbourne, Australia. Participants were randomized to one of the three groups: 1) basic information group who were provided with basic information about RF-EMF to read prior to completing a risk perception assessment questionnaire; 2) precautionary group who were provided with an information pack which included precautionary messages; and 3) personal exposure measurement group who were provided with a summary of their quantitative RF-EMF exposure from MPBS. The same basic information about RF-EMF was also given to the precautionary and personal exposure measurement groups. RESULTS: Participants had a mean (±â€¯SD) age of 36.9 ±â€¯12.5 years; 66.7% were women. Overall, 44.1% had noticed an MPBS in their neighbourhood. The mean (SD) values (from 1 to 7) for risk perceptions to RF-EMF from MPBS were 4.02 (1.67) for basic information, 3.82 (1.62) for precautionary messages, and 3.97 (1.72) for the personal exposure measurement groups. These differences were not statistically significant. Nevertheless, the personal exposure measurement group were more confident that they could protect themselves from RF-EMF than the precautionary or basic information groups. CONCLUSION: Our findings suggest that providing people with personal RF-EMF exposure measurements may not affect their perceived risk from MPBS, but increase their confidence in protecting themselves.


Assuntos
Telefone Celular , Campos Eletromagnéticos , Exposição Ambiental/estatística & dados numéricos , Adulto , Austrália , Feminino , Humanos , Masculino , Percepção , Projetos Piloto , Ondas de Rádio
10.
Bioelectromagnetics ; 40(6): 365-374, 2019 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-31338856

RESUMO

It is well known that applying transcranial alternating current stimulation (tACS) to the scalp can generate artefactual visual perceptions of flashing or shimmering light known as phosphenes. The thresholds for generating these phosphenes have been used by international standards bodies to provide conservative estimates of the field strength required to interfere with human neural functioning and set safety limits accordingly. However, the precise relationship between electric currents and phosphene perception thresholds remains uncertain. The present study used tACS to systematically investigate the effects of the location and the frequency of stimulation on phosphene perception thresholds. These thresholds were obtained from 24 participants using a within-subject design as a function of scalp stimulation sites (FPz-Cz versus Oz-Cz) and stimulation frequency (2-30 Hz in steps of 2 Hz). Phosphene perception thresholds were consistently lower for FPz-Cz stimulation, and regardless of tACS location were lowest for 16 Hz stimulation. Threshold variation between participants was very small, which is meaningful when setting standards based on phosphenes. Bioelectromagnetics. 2019;40:365-374. © 2019 Bioelectromagnetics Society.


Assuntos
Fosfenos/fisiologia , Estimulação Transcraniana por Corrente Contínua/métodos , Adulto , Eletrodos , Feminino , Humanos , Masculino , Estimulação Luminosa , Limiar Sensorial
11.
Environ Res ; 166: 409-417, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29936289

RESUMO

While there has been consistent evidence that symptoms reported by individuals who suffer from Idiopathic Environmental Intolerance attributed to Electromagnetic Fields (IEI-EMF) are not caused by EMF and are more closely associated with a nocebo effect, whether this response is specific to IEI-EMF sufferers and what triggers it, remains unclear. The present experiment tested whether perceived EMF exposure could elicit symptoms in healthy participants, and whether viewing an 'alarmist' video could exacerbate a nocebo response. Participants were randomly assigned to watch either an alarmist (N = 22) or control video (N = 22) before completing a series of sham and active radiofrequency (RF) EMF exposure provocation trials (2 open-label, followed by 12 randomized, double-blind, counterbalanced trials). Pre- and post-video state anxiety and risk perception, as well as belief of exposure and symptom ratings during the open-label and double-blind provocation trials, were assessed. Symptoms were higher in the open-label RF-ON than RF-OFF trial (p < .001). No difference in either symptoms (p = .183) or belief of exposure (p = .144) was observed in the double-blind trials. Participants who viewed the alarmist video had a significant increase in symptoms (p = .041), state anxiety (p < .01) and risk perception (p < .001) relative to the control group. These results reveal the crucial role of awareness and belief in the presentation of symptoms during perceived exposure to EMF, showing that healthy participants exhibit a nocebo response, and that alarmist media reports emphasizing adverse effects of EMF also contribute to a nocebo response.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Sensibilidade Química Múltipla/psicologia , Efeito Nocebo , Método Duplo-Cego , Conhecimentos, Atitudes e Prática em Saúde , Humanos , Ondas de Rádio , Sugestão , Gravação em Vídeo
12.
Bioelectromagnetics ; 39(2): 132-143, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-29125197

RESUMO

The etiology of Idiopathic Environmental Intolerance attributed to Electromagnetic Fields (IEI-EMF) is controversial. While the majority of studies have indicated that there is no relationship between EMF exposure and symptoms reported by IEI-EMF sufferers, concerns about methodological issues have been raised. Addressing these concerns, the present experiment was designed as a series of individual case studies to determine whether there is a relationship between radiofrequency-electromagnetic field (RF-EMF) exposure and an IEI-EMF individual's self-reported symptoms. Three participants aged 44-64 were tested during a series of sham and active exposure trials (2 open-label trials; 12 randomized, double-blind, counterbalanced trials), where symptom severity and exposure detection were scored using 100 mm visual analogue scales. The RF-EMF exposure was a 902-928 MHz spread spectrum digitally modulated signal with an average radiated power output of 1 W (0.3 W/m2 incident power density at the participant). In the double-blind trials, no significant difference in symptom severity or exposure detection was found for any of the participants between the two conditions. Belief of exposure strongly predicted symptom severity score for all participants. Despite accounting for several possible limitations, the present experiment failed to show a relationship between RF-EMF exposure and an IEI-EMF individual's symptoms. Bioelectromagnetics. 39:132-143, 2018. © 2017 Wiley Periodicals, Inc.


Assuntos
Campos Eletromagnéticos/efeitos adversos , Sensibilidade Química Múltipla/etiologia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Ondas de Rádio/efeitos adversos , Autorrelato
13.
Environ Health ; 16(1): 62, 2017 06 19.
Artigo em Inglês | MEDLINE | ID: mdl-28629417

RESUMO

BACKGROUND: Some previous studies have suggested an association between children's use of mobile phones (MPs)/cordless phones (CPs) and development of cognitive function. We evaluated possible longitudinal associations between the use of MPs and CPs in a cohort of primary school children and effects on their cognitive function. METHODS: Data on children's socio-demographics, use of MPs and CPs, and cognitive function were collected at baseline (2010-2012) and follow-up (2012-2013). Cognitive outcomes were evaluated with the CogHealth™ test battery and Stroop Color-Word test. The change in the number of MP/CP voice calls weekly from baseline to follow-up was dichotomized: "an increase in calls" or a "decrease/no change in calls". Multiple linear regression analyses, adjusting for confounders and clustering by school, were performed to evaluate the associations between the change in cognitive outcomes and change in MP and CP exposures. RESULTS: Of 412 children, a larger proportion of them used a CP (76% at baseline and follow-up), compared to a MP (31% at baseline and 43% at follow-up). Of 26 comparisons of changes in cognitive outcomes, four demonstrated significant associations. The increase in MP usage was associated with larger reduction in response time for response inhibition, smaller reduction in the number of total errors for spatial problem solving and larger increase in response time for a Stroop interference task. Except for the smaller reduction in detection task accuracy, the increase in CP usage had no effect on the changes in cognitive outcomes. CONCLUSION: Our study shows that a larger proportion of children used CPs compared to MPs. We found limited evidence that change in the use of MPs or CPs in primary school children was associated with change in cognitive function.


Assuntos
Telefone Celular/estatística & dados numéricos , Cognição , Austrália/epidemiologia , Criança , Campos Eletromagnéticos , Exposição Ambiental , Feminino , Humanos , Masculino , Testes Neuropsicológicos , Estudos Prospectivos
14.
Eur J Appl Physiol ; 117(5): 1025-1037, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28343279

RESUMO

PURPOSE: Many researchers have addressed the potential effects of hyperthermia and dehydration on cognition, often revealing contradictory outcomes. A possible reason for this inconsistency is that experiments may have been inadequately designed for such effects. In this study, the impact of hyperthermia, dehydration and their combination on cognition were evaluated in eight young males, after accounting for a range of experimental limitations. METHODS: Passive heating and thermal clamping at two mean body temperatures (36.5, 38.5 °C) were performed under three hydration states (euhydrated, 3 and 5% dehydrated) to assess their effects on difficulty-matched working memory and visual perception tasks, and on a difficulty manipulated perceptual task. Data were analysed according to signal detection theory to isolate changes in response sensitivity, bias and speed. RESULTS: Neither moderate hyperthermia (P = 0.141) nor dehydration (P > 0.604) modified response sensitivity, nor did they significantly interact (P > 0.698). Therefore, the ability to distinguish correct from incorrect responses was unaffected. Nevertheless, hyperthermia, but not dehydration (P = 0.301), reduced the response bias (-0.08 versus 2.2 [normothermia]; P = 0.010) and reaction time (mean reduction 49 ms; P < 0.001), eliciting more liberal and faster responses (P = 0.010). Response bias was reduced for the memory relative to the perceptual task (P = 0.037), and this effect was enhanced during hyperthermia (P = 0.031). CONCLUSIONS: These observations imply that, once potentially confounding influences were controlled, moderate hyperthermia, significant dehydration and their combined effects had insufficient impact to impair cognition within the memory and perceptual domains tested. Nonetheless, moderate hyperthermia elicited more liberal and rapid responses.


Assuntos
Cognição , Desidratação/fisiopatologia , Transtornos de Estresse por Calor/fisiopatologia , Adulto , Temperatura Corporal , Humanos , Masculino , Memória de Curto Prazo , Percepção , Distribuição Aleatória
15.
Risk Anal ; 37(3): 583-597, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27163281

RESUMO

Precautionary messages have been shown to increase recipients' threat perceptions about radio-frequency electromagnetic fields (RF-EMFs) emitted by mobile phones and mobile phone base stations. The current study explored the interplay of variables on the side of message recipients with this effect. The individual difference variables of interest were gender, trait anxiety, personal need for structure, and personal fear of invalidity. Furthermore, the study determined whether the increased threat perception is accompanied by emotional distress. A total of 298 university students answered a survey after reading either a basic text about RF-EMFs or a text including precautionary information. Linear multiple regression with interactions analyses showed that the effect of precautionary messages differed for people with different levels of trait anxiety. How trait anxiety was related to the effect of precautionary messages in turn depended on participants' gender. Personal need for structure and personal fear of invalidity were mostly unrelated to the effect of precautionary messages. Regarding participants' emotional distress, we found no difference in state anxiety scores between those participants who received precautionary information and those who did not. The findings show that the effects of precautionary messages on threat perception depend on individual difference variables such as recipients' trait anxiety and gender. Also, the fact that precautionary communication did not result in heightened state anxiety challenges the assumption that precautionary messages induce fear or anxiety.

16.
Environ Health ; 15: 26, 2016 Feb 19.
Artigo em Inglês | MEDLINE | ID: mdl-26892106

RESUMO

BACKGROUND: Use of mobile (MP) and cordless phones (CP) is common among young children, but whether the resulting radiofrequency exposure affects development of cognitive skills is not known. Small changes have been found in older children. This study focused on children's exposures to MP and CP and cognitive development. The hypothesis was that children who used these phones would display differences in cognitive function compared to those who did not. METHODS: We recruited 619 fourth-grade students (8-11 years) from 37 schools around Melbourne and Wollongong, Australia. Participants completed a short questionnaire, a computerised cognitive test battery, and the Stroop colour-word test. Parents completed exposure questionnaires on their child's behalf. Analysis used multiple linear regression. The principal exposure-metrics were the total number of reported MP and CP calls weekly categorised into no use ('None'); use less than or equal to the median amount ('Some'); and use more than the median ('More'). The median number of calls/week was 2.5 for MP and 2.0 for CP. RESULTS: MP and CP use for calls was low; and only 5 of 78 comparisons of phone use with cognitive measures were statistically significant. The reaction time to the response-inhibition task was slower in those who used an MP 'More' compared to the 'Some' use group and non-users. For CP use, the response time to the Stroop interference task was slower in the 'More' group versus the 'Some' group, and accuracy was worse in visual recognition and episodic memory tasks and the identification task. In an additional exploratory analysis, there was some evidence of a gender effect on mean reaction times. The highest users for both phone types were girls. CONCLUSIONS: Overall, there was little evidence cognitive function was associated with CP and MP use in this age group. Although there was some evidence that effects of MP and CP use on cognition may differ by gender, this needs further exploration. CP results may be more reliable as parents estimated children's phone use and the CPs were at home; results for CP use were broadly consistent with our earlier study of older children.


Assuntos
Telefone Celular/estatística & dados numéricos , Cognição , Atenção , Austrália/epidemiologia , Criança , Exposição Ambiental , Feminino , Humanos , Masculino , Aprendizagem em Labirinto , Memória , Pais , Estudos Prospectivos , Tempo de Reação , Instituições Acadêmicas , Inquéritos e Questionários
17.
Neural Plast ; 2016: 6526437, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-27019754

RESUMO

Prolonged heavy exposure to cannabis is associated with impaired cognition and brain functional and structural alterations. We recently reported attenuated mismatch negativity (MMN) and altered P50 sensory gating in chronic cannabis users. This study investigated the extent of brain functional recovery (indexed by MMN and P50) in chronic users after cessation of use. Eighteen ex-users (median 13.5 years prior regular use; median 3.5 years abstinence) and 18 nonusers completed (1) a multifeature oddball task with duration, frequency, and intensity deviants and (2) a P50 paired-click paradigm. Trend level smaller duration MMN amplitude and larger P50 ratios (indicative of poorer sensory gating) were observed in ex-users compared to controls. Poorer P50 gating correlated with prior duration of cannabis use. Duration of abstinence was positively correlated with duration MMN amplitude, even after controlling for age and duration of cannabis use. Impaired sensory gating and attenuated MMN amplitude tended to persist in ex-users after prolonged cessation of use, suggesting a lack of full recovery. An association with prolonged duration of prior cannabis use may indicate persistent cannabis-related alterations to P50 sensory gating. Greater reductions in MMN amplitude with increasing abstinence (positive correlation) may be related to either self-medication or an accelerated aging process.


Assuntos
Córtex Cerebral/fisiopatologia , Potenciais Evocados , Fumar Maconha/fisiopatologia , Filtro Sensorial , Estimulação Acústica , Adulto , Eletroencefalografia , Potenciais Evocados Auditivos , Feminino , Humanos , Masculino , Fumar Maconha/efeitos adversos , Pessoa de Meia-Idade , Adulto Jovem
18.
Ergonomics ; 59(4): 504-13, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26280297

RESUMO

Motorcycle protective clothing can be uncomfortably hot during summer, and this experiment was designed to evaluate the physiological significance of that burden. Twelve males participated in four, 90-min trials (cycling 30 W) across three environments (25, 30, 35 °C [all 40% relative humidity]). Clothing was modified between full and minimal injury protection. Both ensembles were tested at 25 °C, with only the more protective ensemble investigated at 30 and 35 °C. At 35 °C, auditory canal temperature rose at 0.02 °C min(-1) (SD 0.005), deviating from all other trials (p < 0.05). The thresholds for moderate (>38.5 °C) and profound hyperthermia (>40.0 °C) were predicted to occur within 105 min (SD 20.6) and 180 min (SD 33.0), respectively. Profound hyperthermia might eventuate in ~10 h at 30 °C, but should not occur at 25 °C. These outcomes demonstrate a need to enhance the heat dissipation capabilities of motorcycle clothing designed for summer use in hot climates, but without compromising impact protection. Practitioner's Summary: Motorcycle protective clothing can be uncomfortably hot during summer. This experiment was designed to evaluate the physiological significance of this burden across climatic states. In the heat, moderate (>38.5 °C) and profound hyperthermia (>40.0 °C) were predicted to occur within 105 and 180 min, respectively.


Assuntos
Febre/etiologia , Frequência Cardíaca , Temperatura Alta/efeitos adversos , Motocicletas , Consumo de Oxigênio , Roupa de Proteção , Temperatura Cutânea , Sudorese , Adulto , Austrália , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estações do Ano
19.
Int J Neuropsychopharmacol ; 17(5): 705-13, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24405657

RESUMO

The brain-derived neurotropic factor (BDNF) Val66Met polymorphism has been associated with abnormalities of synaptic plasticity in animal models, and abnormalities in motor cortical plasticity have also been described in humans using transcranial direct current stimulation. No study has yet been done on plasticity in non-motor regions, and the effect of two Met alleles (i.e. 'Met dose') is not well understood. We studied the effect of the BDNF Val66Met polymorphism on the after-effects of transcranial direct current stimulation and tetanic auditory stimulation in 65 subjects (23; Val66Val, 22; Val66Met and 20; Met66Met genotypes). In the first session, motor evoked potentials (MEP) were recorded under stereotaxic guidance for 90 min after 9 min of anodal transcranial direct current stimulation (TDCS). In the second session, auditory-evoked potentials (AEP) were recorded before and after 2 min of auditory 13 Hz tetanic stimulation. There was a difference in MEP facilitation post-TDCS comparing Met carriers with non-Met carriers, with Met carriers having a modest late facilitation at 30-90 min. There was no difference in responses between Val66Met genotype and Met66Met genotype subjects. Tetanic auditory stimulation also produced late facilitation of N1-P2 AEP at 25 min, but there was no apparent effect of genetic status. This study indicates that Met66Met carriers behave like Val66Met carriers for TDCS-induced plasticity, and produce a late facilitation of MEPs. Auditory cortical plasticity was not affected by the BDNF Val66Met polymorphism. This study sheds light on the differences between auditory and motor cortical plasticity and the role of the BDNF Val66Met polymorphism.


Assuntos
Córtex Auditivo/fisiologia , Percepção Auditiva , Fator Neurotrófico Derivado do Encéfalo/genética , Córtex Motor/fisiologia , Plasticidade Neuronal , Polimorfismo de Nucleotídeo Único , Estimulação Acústica , Adulto , Alelos , Percepção Auditiva/genética , Estimulação Elétrica , Potenciais Evocados Auditivos/genética , Potencial Evocado Motor/genética , Feminino , Técnicas de Genotipagem , Humanos , Masculino , Pessoa de Meia-Idade , Plasticidade Neuronal/genética , Estimulação Magnética Transcraniana , Adulto Jovem
20.
Health Phys ; 126(4): 241-248, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38381972

RESUMO

ABSTRACT: Concerns have been raised about the possibility of effects from exposure to short wavelength light (SWL), defined here as 380-550 nm, on human health. The spectral sensitivity of the human circadian timing system peaks at around 480 nm, much shorter than the peak sensitivity of daytime vision (i.e., 555 nm). Some experimental studies have demonstrated effects on the circadian timing system and on sleep from SWL exposure, especially when SWL exposure occurs in the evening or at night. The International Commission on Non-Ionizing Radiation Protection (ICNIRP) has identified a lack of consensus among public health officials regarding whether SWL from artificial sources disrupts circadian rhythm, and if so, whether SWL-disrupted circadian rhythm is associated with adverse health outcomes. Systematic reviews of studies designed to examine the effects of SWL on sleep and human health have shown conflicting results. There are many variables that can affect the outcome of these experimental studies. One of the main problems in earlier studies was the use of photometric quantities as a surrogate for SWL exposure. Additionally, the measurement of ambient light may not be an accurate measure of the amount of light impinging on the intrinsically photosensitive retinal ganglion cells, which are now known to play a major role in the human circadian timing system. Furthermore, epidemiological studies of long-term effects of chronic SWL exposure per se on human health are lacking. ICNIRP recommends that an analysis of data gaps be performed to delineate the types of studies needed, the parameters that should be addressed, and the methodology that should be applied in future studies so that a decision about the need for exposure guidelines can be made. In the meantime, ICNIRP supports some recommendations for how the quality of future studies might be improved.


Assuntos
Melatonina , Humanos , Ritmo Circadiano/efeitos da radiação , Sono/efeitos da radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA