RESUMO
BACKGROUND: Laboratory screening for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a key mitigation measure to avoid the spread of infection among recruits starting basic combat training in a congregate setting. Because viral nucleic acid can be detected persistently after recovery, we evaluated other laboratory markers to distinguish recruits who could proceed with training from those who were infected. METHODS: Recruits isolated for coronavirus disease 2019 (COVID-19) were serially tested for SARS-CoV-2 subgenomic ribonucleic acid (sgRNA), and viral load (VL) by reverse-transcriptase polymerase chain reaction (RT-PCR), and for anti- SARS-CoV-2. Cluster and quadratic discriminant analyses of results were performed. RESULTS: Among 229 recruits isolated for COVID-19, those with a RT-PCR cycle threshold >30.49 (sensitivity 95%, specificity 96%) or having sgRNA log10 RNA copies/mL <3.09 (sensitivity and specificity 96%) at entry into isolation were likely SARS-CoV-2 uninfected. Viral load >4.58 log10 RNA copies/mL or anti-SARS-CoV-2 signal-to-cutoff ratio <1.38 (VL: sensitivity and specificity 93%; anti-SARS-CoV-2: sensitivity 83%, specificity 79%) had comparatively lower sensitivity and specificity when used alone for discrimination of infected from uninfected. CONCLUSIONS: Orthogonal laboratory assays used in combination with RT-PCR may have utility in determining SARS-CoV-2 infection status for decisions regarding isolation.
Assuntos
COVID-19 , Humanos , COVID-19/diagnóstico , SARS-CoV-2 , Teste para COVID-19 , Sensibilidade e Especificidade , RNA , RNA Viral/genética , Reação em Cadeia da Polimerase Via Transcriptase ReversaRESUMO
BACKGROUND: Recent outbreaks between 2015-17 and production delays have led to a yellow fever vaccine shortage. Therefore, there is an urgent need for new yellow fever vaccines with improved production scalability. A next-generation live-attenuated yellow fever vaccine candidate (vYF), produced in a Vero cell line has shown similar immunogenicity to licensed yellow fever vaccines in preclinical studies. In this study, we aimed to report the safety and immunogenicity of vYF in human clinical trial participants. METHODS: In this first in-human, phase 1 randomised, observer-blind, active-controlled, dose-ranging clinical trial conducted at a single centre in the USA (Walter Reed Army Institute of Research, Silver Spring, MD, USA), 72 healthy adults (aged 18-60 years), without a known history of flavivirus infection or vaccination were randomly assigned (1:1:1:1) using interactive response technology to receive one dose of either vYF at 4, 5 or 6 Log CCID50 or the licensed YF-VAX (18 individuals per group). The primary outcomes were safety, neutralising antibody (NAb) titres through D180 post-vaccination in the per-protocol analysis set (comprised of yellow fever-naive participants who received their intended vaccine and provided a valid post-vaccination blood sample), and occurrence, and level of yellow fever viraemia in each vaccine group through D14 post-vaccination. FINDINGS: All vYF doses had a safety and tolerability profile similar to YF-VAX. The most frequently reported solicited injection site reactions (vYF groups vs YF-VAX group) were pain (22% [12 of 54 participants, 95% CI 12-36] vs 28% [five of 18 participants, 10-54]), and erythema (13% [seven of 54 participants, 5-25] vs 39% [seven of 18 participants, 17-64]), with headache (32% [17 of 54 participants, 20-46] vs 44% [eight of 18 participants, 22-69]) and malaise (26% [14 of 54 participants, 15-40] vs 33% [six of 18 participants, 13-59]) as the most frequently reported solicited systemic reactions. One grade 3 solicited reaction (erythema) reported in the YF-VAX group resolved spontaneously. No serious unsolicited adverse events or deaths were reported. Viraemia was transiently detected in 50 participants between D4 and D10 in all groups and was observed in more participants or for a longer time in the vYF 6 Log CCID50 and YF-VAX groups. All yellow fever-naive vaccine recipients across the study groups seroconverted yielding four-fold increase from baseline in yellow fever NAb titres measured by yellow fever microneutralisation assay by D28 and were seroprotected with yellow fever NAb titres of at least 10 [1/dil]). Overall, 100% (18 of 18 participants, 95% CI 82-100), 89% (16 participants, 65-99), 100% (18 participants, 82-100), and 94% (17 participants, 73-100) of participants in the vYF 4 Log, vYF 5 Log, vYF 6 Log CCID50 groups, and YF-VAX group, respectively, remained seroprotected through D180. INTERPRETATION: vYF has a similar safety and immunogenicity profile to YF-VAX. In general, the vYF 5 Log CCID50 dose appeared to show optimal viraemia, safety, and immunogenicity, and was chosen for subsequent development. FUNDING: Sanofi.
RESUMO
BACKGROUND: Limited epidemiologic studies have been conducted in Jordan describing the HIV epidemic. This study aimed to address this gap to inform HIV prevention and control. METHODS: A nationally-representative cross-sectional study was conducted among adults living with HIV in Jordan. Laboratory testing included HIV viral load and next-generation-sequencing-based clinical genotype. Log-binomial regression estimated risk ratios (RRs) and 95% confidence intervals (CIs). RESULTS: Among 231 (70%) participants, most were male (184/80%), and from Jordan (217/94%). Among 188 treatment-experienced-participants (>6 months), 165 (88%) were virally suppressed. High-level resistance was most frequent against nucleoside reverse transcriptase inhibitor (13/81%), and integrase-strand transfer inhibitor (INSTI) (10/62%) drugs among viremic (≥1000 HIV copies/mL) treatment-experienced participants with drug-resistant mutations (DRMs, n = 16). Common HIV subtypes (n = 43) were B (6/14%), A1 (5/12%), and CRF01_AE (5/12%); additionally, novel recombinant forms were detected. In multivariate analysis, independently higher risk for late diagnosis (n = 49) was observed with diagnosis through blood donation (vs check-up: RR 2.20, 95%CI 1.16-4.17) and earlier time-period of diagnosis (1986-2014 vs 2015-2021: RR 2.87, 95%CI 1.46-5.62). CONCLUSIONS: Late diagnosis and INSTI resistance endanger national HIV prevention and treatment in Jordan-high-level resistance to INSTI suggests therapeutic drug monitoring is needed for treatment efficacy and conservation of treatment options.
Assuntos
Fármacos Anti-HIV , Farmacorresistência Viral , Infecções por HIV , Carga Viral , Humanos , Jordânia/epidemiologia , Infecções por HIV/epidemiologia , Infecções por HIV/virologia , Infecções por HIV/tratamento farmacológico , Masculino , Adulto , Feminino , Estudos Transversais , Farmacorresistência Viral/genética , Pessoa de Meia-Idade , Fármacos Anti-HIV/uso terapêutico , Fármacos Anti-HIV/farmacologia , HIV-1/efeitos dos fármacos , HIV-1/genética , Adulto Jovem , Genótipo , AdolescenteRESUMO
BACKGROUND: Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) are the most common bacterial causes of sexually transmitted infection (STI) in the United States (US). The purpose of this study was to determine the frequency of reinfection during a six-month study period and to evaluate the retesting interval for those infected with CT or NG. METHODS: We conducted a prospective, six-month follow-up study among US military personnel with new onset, laboratory-confirmed CT or NG, recruited from an STI clinic at a large military base from January 2018 to January 2020. Each participant was randomly assigned to one of four groups, which differed only by the timing of the first study-associated follow-up visit after CT or NG diagnosis. RESULTS: Of the 347 initially recruited into the study, 267 participants completed a follow-up visit prior to their scheduled, final visit 6 months after initial infection. The median age at enrollment was 22 years and 41.0% were female. There were 32 (12.0%) reinfections (30 CT and 2 NG) after treatment of an index diagnosis of CT or NG within the six-month study period. Six of the CT reinfections were only detected at the final visit. A review of medical records revealed additional CT and NG reinfections. The probability of detecting a reinfection did not vary significantly by timing of follow-up. CONCLUSIONS: The likelihood of detecting CT or NG reinfection did not differ according to time of follow up visit among study participants, thus supporting CDC guidance to retest three months post treatment. Efforts should continue to focus on STI prevention and risk reduction.
Assuntos
Infecções por Chlamydia , Gonorreia , Infecções Sexualmente Transmissíveis , Humanos , Feminino , Estados Unidos/epidemiologia , Masculino , Gonorreia/diagnóstico , Gonorreia/epidemiologia , Gonorreia/prevenção & controle , Chlamydia trachomatis , Reinfecção , Seguimentos , Estudos Prospectivos , Infecções por Chlamydia/diagnóstico , Infecções por Chlamydia/epidemiologia , Infecções por Chlamydia/prevenção & controle , Infecções Sexualmente Transmissíveis/prevenção & controle , Neisseria gonorrhoeae , PrevalênciaRESUMO
Fc-mediated virus entry has been observed for many viruses, but the characterization of this activity in convalescent plasma against SARS-CoV-2 Variants of Concern (VOC) is undefined. In this study, we evaluated Fc-mediated viral entry (FVE) on FcγRIIa-expressing HEK293 cells in the presence of SARS-CoV-2 convalescent plasma and compared it with SARS-CoV-2 pseudovirus neutralization using ACE2-expressing HEK293 cells. The plasma were collected early in the pandemic from 39 individuals. We observed both neutralization and FVE against the infecting Washington SARS-CoV-2 strain for 31% of plasmas, neutralization, but not FVE for 61% of plasmas, and no neutralization or FVE for 8% of plasmas. Neutralization titer correlated significantly with the plasma dilution at which maximum FVE was observed, indicating Fc-mediated uptake peaked as neutralization potency waned. While total Spike-specific plasma IgG levels were similar between plasma that mediated FVE and those that did not, Spike-specific plasma IgM levels were significantly higher in plasma that did not mediate FVE. Plasma neutralization titers against the Alpha (B.1.1.7), Beta (B.1.351), Gamma (P.1) and Delta (B.1.617.2) VOC were significantly lower than titers against the Washington strain, while plasma FVE activity against the VOC was either higher or similar. This is the first report to demonstrate a functional shift in convalescent plasma antibodies from neutralizing and FVE-mediating against the earlier Washington strain, to an activity mediating only FVE and no neutralization activity against the emerging VOC, specifically the Beta (B.1.351) and Gamma (P.1) VOC. It will be important to determine the in vivo relevance of these findings.
Assuntos
COVID-19 , SARS-CoV-2 , COVID-19/terapia , Células HEK293 , Humanos , Imunização Passiva , Fragmentos Fc das Imunoglobulinas , Glicoproteína da Espícula de Coronavírus , Internalização do Vírus , Soroterapia para COVID-19RESUMO
Combining diagnostic specimens into pools has been considered as a strategy to augment throughput, decrease turnaround time, and leverage resources. This study utilized a multi-parametric approach to assess optimum pool size, impact of automation, and effect of nucleic acid amplification chemistries on the detection of SARS-CoV-2 RNA in pooled samples for surveillance testing on the Hologic Panther Fusion® System. Dorfman pooled testing was conducted with previously tested SARS-CoV-2 nasopharyngeal samples using Hologic's Aptima® and Panther Fusion® SARS-CoV-2 Emergency Use Authorization assays. A manual workflow was used to generate pool sizes of 5:1 (five samples: one positive, four negative) and 10:1. An automated workflow was used to generate pool sizes of 3:1, 4:1, 5:1, 8:1 and 10:1. The impact of pool size, pooling method, and assay chemistry on sensitivity, specificity, and lower limit of detection (LLOD) was evaluated. Both the Hologic Aptima® and Panther Fusion® SARS-CoV-2 assays demonstrated >85% positive percent agreement between neat testing and pool sizes ≤5:1, satisfying FDA recommendation. Discordant results between neat and pooled testing were more frequent for positive samples with CT>35. Fusion® CT (cycle threshold) values for pooled samples increased as expected for pool sizes of 5:1 (CT increase of 1.92-2.41) and 10:1 (CT increase of 3.03-3.29). The Fusion® assay demonstrated lower LLOD than the Aptima® assay for pooled testing (956 vs 1503 cp/mL, pool size of 5:1). Lowering the cut-off threshold of the Aptima® assay from 560 kRLU (manufacturer's setting) to 350 kRLU improved the assay sensitivity to that of the Fusion® assay for pooled testing. Both Hologic's SARS-CoV-2 assays met the FDA recommended guidelines for percent positive agreement (>85%) for pool sizes ≤5:1. Automated pooling increased test throughput and enabled automated sample tracking while requiring less labor. The Fusion® SARS-CoV-2 assay, which demonstrated a lower LLOD, may be more appropriate for surveillance testing.
Assuntos
COVID-19 , SARS-CoV-2 , Humanos , SARS-CoV-2/genética , RNA Viral/genética , COVID-19/diagnóstico , Técnicas de Diagnóstico Molecular/métodos , Automação , Sensibilidade e EspecificidadeRESUMO
Serological assessment of SARS-CoV-2 specific responses are an essential tool for determining the prevalence of past SARS-CoV-2 infections in the population especially when testing occurs after symptoms have developed and limited contact tracing is in place. The goal of our study was to test a new 10-plex electro-chemiluminescence-based assay to measure IgM and IgG responses to the spike proteins from multiple human coronaviruses including SARS-CoV-2, assess the epitope specificity of the SARS-CoV-2 antibody response against full-length spike protein, receptor-binding domain and N-terminal domain of the spike protein, and the nucleocapsid protein. We carried out the assay on samples collected from three sample groups: subjects diagnosed with COVID-19 from the U.S. Army hospital at Camp Humphreys in Pyeongtaek, South Korea; healthcare administrators from the same hospital but with no reported diagnosis of COVID-19; and pre-pandemic samples. We found that the new CoV-specific multiplex assay was highly sensitive allowing plasma samples to be diluted 1:30,000 with a robust signal. The reactivity of IgG responses to SARS-CoV-2 nucleocapsid protein and IgM responses to SARS-CoV-2 spike protein could distinguish COVID-19 samples from non-COVID-19 and pre-pandemic samples. The data from the three sample groups also revealed a unique pattern of cross-reactivity between SARS-CoV-2 and SARS-CoV-1, MERS-CoV, and seasonal coronaviruses HKU1 and OC43. Our findings show that the CoV-2 IgM response is highly specific while the CoV-2 IgG response is more cross-reactive across a range of human CoVs and also showed that IgM and IgG responses show distinct patterns of epitope specificity. In summary, this multiplex assay was able to distinguish samples by COVID-19 status and characterize distinct trends in terms of cross-reactivity and fine-specificity in antibody responses, underscoring its potential value in diagnostic or serosurveillance efforts.
Assuntos
Anticorpos Antivirais/imunologia , COVID-19/imunologia , SARS-CoV-2/imunologia , Adulto , Anticorpos Antivirais/análise , Formação de Anticorpos , Reações Cruzadas , Feminino , Humanos , Imunoglobulina G/análise , Imunoglobulina G/imunologia , Imunoglobulina M/análise , Imunoglobulina M/imunologia , Luminescência , Masculino , Pessoa de Meia-Idade , Coronavírus da Síndrome Respiratória do Oriente Médio/imunologia , Militares , Proteínas do Nucleocapsídeo/imunologia , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/imunologia , SARS-CoV-2/patogenicidade , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus/imunologia , Estados UnidosRESUMO
BACKGROUND: Middle East respiratory syndrome (MERS) coronavirus causes a highly fatal lower-respiratory tract infection. There are as yet no licensed MERS vaccines or therapeutics. This study (WRAIR-2274) assessed the safety, tolerability, and immunogenicity of the GLS-5300 MERS coronavirus DNA vaccine in healthy adults. METHODS: This study was a phase 1, open-label, single-arm, dose-escalation study of GLS-5300 done at the Walter Reed Army Institute for Research Clinical Trials Center (Silver Spring, MD, USA). We enrolled healthy adults aged 18-50 years; exclusion criteria included previous infection or treatment of MERS. Eligible participants were enrolled sequentially using a dose-escalation protocol to receive 0·67 mg, 2 mg, or 6 mg GLS-5300 administered by trained clinical site staff via a single intramuscular 1 mL injection at each vaccination at baseline, week 4, and week 12 followed immediately by co-localised intramuscular electroporation. Enrolment into the higher dose groups occurred after a safety monitoring committee reviewed the data following vaccination of the first five participants at the previous lower dose in each group. The primary outcome of the study was safety, assessed in all participants who received at least one study treatment and for whom post-dose study data were available, during the vaccination period with follow-up through to 48 weeks after dose 3. Safety was measured by the incidence of adverse events; administration site reactions and pain; and changes in safety laboratory parameters. The secondary outcome was immunogenicity. This trial is registered at ClinicalTrials.gov (number NCT02670187) and is completed. FINDINGS: Between Feb 17 and July 22, 2016, we enrolled 75 individuals and allocated 25 each to 0·67 mg, 2 mg, or 6 mg GLS-5300. No vaccine-associated serious adverse events were reported. The most common adverse events were injection-site reactions, reported in 70 participants (93%) of 75. Overall, 73 participants (97%) of 75 reported at least one solicited adverse event; the most common systemic symptoms were headache (five [20%] with 0·67 mg, 11 [44%] with 2 mg, and seven [28%] with 6 mg), and malaise or fatigue (five [20%] with 0·67 mg, seven [28%] with 2 mg, and two [8%] with 6 mg). The most common local solicited symptoms were administration site pain (23 [92%] with all three doses) and tenderness (21 [84%] with all three doses). Most solicited symptoms were reported as mild (19 [76%] with 0·67 mg, 20 [80%] with 2 mg, and 17 [68%] with 6 mg) and were self-limiting. Unsolicited symptoms were reported for 56 participants (75%) of 75 and were deemed treatment-related for 26 (35%). The most common unsolicited adverse events were infections, occurring in 27 participants (36%); six (8%) were deemed possibly related to study treatment. There were no laboratory abnormalities of grade 3 or higher that were related to study treatment; laboratory abnormalities were uncommon, except for 15 increases in creatine phosphokinase in 14 participants (three participants in the 0·67 mg group, three in the 2 mg group, and seven in the 6 mg group). Of these 15 increases, five (33%) were deemed possibly related to study treatment (one in the 2 mg group and four in the 6 mg group). Seroconversion measured by S1-ELISA occurred in 59 (86%) of 69 participants and 61 (94%) of 65 participants after two and three vaccinations, respectively. Neutralising antibodies were detected in 34 (50%) of 68 participants. T-cell responses were detected in 47 (71%) of 66 participants after two vaccinations and in 44 (76%) of 58 participants after three vaccinations. There were no differences in immune responses between dose groups after 6 weeks. At week 60, vaccine-induced humoral and cellular responses were detected in 51 (77%) of 66 participants and 42 (64%) of 66, respectively. INTERPRETATION: The GLS-5300 MERS coronavirus vaccine was well tolerated with no vaccine-associated serious adverse events. Immune responses were dose-independent, detected in more than 85% of participants after two vaccinations, and durable through 1 year of follow-up. The data support further development of the GLS-5300 vaccine, including additional studies to test the efficacy of GLS-5300 in a region endemic for MERS coronavirus. FUNDING: US Department of the Army and GeneOne Life Science.
Assuntos
Anticorpos Neutralizantes/sangue , Anticorpos Antivirais/sangue , DNA Viral/imunologia , Coronavírus da Síndrome Respiratória do Oriente Médio/imunologia , Vacinas Virais/imunologia , Adulto , Fadiga/induzido quimicamente , Feminino , Cefaleia/induzido quimicamente , Humanos , Imunidade Celular , Reação no Local da Injeção , Masculino , Vacinas Virais/administração & dosagem , Vacinas Virais/efeitos adversos , Adulto JovemRESUMO
To determine whether CD8+ T lymphocytes from Thai donor cells are susceptible to HIV-1 infection, undepleted peripheral blood mononuclear cells (PBMC) and CD8-enriched PBMC were infected with HIV-1 Thai subtype B and CRF01_AE (E) primary isolates. Virus kinetics in HIV-1 infection of CD4+ and CD8+ T lymphocytes peaked at day 7 or 10 post infection (pi); the TCID50 used for cell infection was proportional to the level of p24 production in the cultures. We also found that the level of p24 antigen in the supernatants of infected undepleted PBMC was significantly higher than that of infected CD8-enriched PBMC. Interestingly, both single positive T lymphocytes (CD4+ and CD8+ T lymphocytes) as well as double positive CD4+/CD8+ T lymphocytes were infected with HIV-1. The double positive T lymphocytes in PBMC were found only in the presence of both CD4+ and CD8+ T lymphocytes. The majority of p24+/CD4-/CD8- T lymphocytes were HIV-1 infected CD4 down-modulated PBMC. This report provides direct evidence that single positive CD8+ T lymphocytes and double positive CD4+/ CD8+ T lymphocytes from Thai donors can be infected with HIV-1 subtypes B and E in vitro.
Assuntos
Linfócitos T CD8-Positivos/virologia , Infecções por HIV/imunologia , HIV-1/patogenicidade , Linfócitos T CD4-Positivos/virologia , Proteína do Núcleo p24 do HIV/imunologia , Soronegatividade para HIV/imunologia , HIV-1/imunologia , Humanos , Técnicas In Vitro , TailândiaRESUMO
When evaluating candidate prophylactic HIV and cancer vaccines, intracellular cytokine staining (ICS) assays that measure the frequency and magnitude of antigen-specific T-cell subsets are one tool to monitor immunogen performance and make product advancement decisions. To assess the inter-laboratory assay variation among multiple laboratories testing vaccine candidates, the NIH/NIAID/DAIDS in collaboration with BD Biosciences implemented an ICS Quality Assurance Program (QAP). Seven rounds of testing have been conducted in which 16 laboratories worldwide participated. In each round, IFN-γ, IL-2 and/or TNF-α responses in CD4+ and CD8+ T-cells to CEF or CMV pp65 peptide mixes were tested using cryopreserved peripheral blood mononuclear cells (PBMC) from CMV seropositive donors. We found that for responses measured above 0.2%, inter-laboratory %CVs were, on average, 35%. No differences in inter-laboratory variation were observed if a 4-color antibody cocktail or a 7-color combination was used. Moreover, the data allowed identification of important sources of variability for flow cytometry-based assays, including: number of collected events, gating strategy and instrument setup and performance. As a consequence, in this multi-site study we were able to define pass and fail criteria for ICS assays, which will be adopted in the subsequent rounds of testing and could be easily extrapolated to QAP for other flow cytometry-based assays.
Assuntos
Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Citometria de Fluxo/métodos , Interferon gama/sangue , Interleucina-2/sangue , Fator de Necrose Tumoral alfa/sangue , Citometria de Fluxo/normas , Corantes Fluorescentes/química , Humanos , Leucócitos Mononucleares/imunologia , Variações Dependentes do Observador , Fosfoproteínas/imunologia , Proteínas de Saccharomyces cerevisiae/imunologia , Estatísticas não Paramétricas , Proteínas de Transporte Vesicular/imunologia , Proteínas da Matriz Viral/imunologiaRESUMO
BACKGROUND: We conducted a novel pilot study comparing different delivery routes of ALVAC-HIV (vCP205), a canarypox vaccine containing HIV gene inserts: env, gag and pol. We explored the concept that direct ex vivo targeting of human dendritic cells (DC) would enhance the immune response compared to either conventional intramuscular or intradermal injections of the vaccine alone. METHODOLOGY/PRINCIPAL FINDINGS: Healthy HIV-1 uninfected volunteers were administered ALVAC-HIV or placebo by intramuscular injection (i.m.), intradermal injection (i.d.) or subcutaneous injection (s.q.) of autologous ex vivo transfected DC at months 0, 1, 3 and 6. All vaccine delivery routes were well tolerated. Binding antibodies were observed to both the ALVAC vector and HIV-1 gp160 proteins. Modest cellular responses were observed in 2/7 individuals in the DC arm and 1/8 in the i.m. arm as determined by IFN-γ ELISPOT. Proliferative responses were most frequent in the DC arm where 4/7 individuals had measurable responses to multiple HIV-1 antigens. Loading DC after maturation resulted in lower gene expression, but overall better responses to both HIV-1 and control antigens, and were associated with better IL-2, TNF-α and IFN-γ production. CONCLUSIONS/SIGNIFICANCE: ALVAC-HIV delivered i.m., i.d. or s.q. with autologous ex vivo transfected DC proved to be safe. The DC arm was most immunogenic. Proliferative immune responses were readily detected with only modest cytotoxic CD8 T cell responses. Loading mature DC with the live viral vaccine induced stronger immune responses than loading immature DC, despite increased transgene expression with the latter approach. Volunteers who received the autologous vaccine loaded mature DC developed a broader and durable immune response compared to those vaccinated by conventional routes. TRIAL REGISTRATION: ClinicalTrials.gov NCT00013572.
Assuntos
Vacinas contra a AIDS/imunologia , Células Dendríticas/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Vacinas contra a AIDS/administração & dosagem , Adulto , Citocinas/sangue , Citocinas/imunologia , Células Dendríticas/metabolismo , Células Dendríticas/transplante , Método Duplo-Cego , Ensaio de Imunoadsorção Enzimática , Feminino , Expressão Gênica/imunologia , Perfilação da Expressão Gênica , Anticorpos Anti-HIV/sangue , Anticorpos Anti-HIV/imunologia , Proteína gp120 do Envelope de HIV/imunologia , Proteína gp160 do Envelope de HIV/imunologia , Infecções por HIV/prevenção & controle , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Injeções Intradérmicas , Injeções Intramusculares , Leucócitos Mononucleares/imunologia , Leucócitos Mononucleares/metabolismo , Masculino , Projetos Piloto , Linfócitos T Citotóxicos/imunologia , Linfócitos T Citotóxicos/metabolismo , Fatores de Tempo , Vacinas Virais/imunologiaRESUMO
A critical priority for human immunodeficiency virus type 1 (HIV-1) vaccine development is standardization of reagents and assays for evaluation of immune responses elicited by candidate vaccines. To provide a panel of viral reagents from multiple vaccine trial sites, 60 international HIV-1 isolates were expanded in peripheral blood mononuclear cells and characterized both genetically and biologically. Ten isolates each from clades A, B, C, and D and 10 isolates each from CRF01_AE and CRF02_AG were prepared from individuals whose HIV-1 infection was evaluated by complete genome sequencing. The main criterion for selection was that the candidate isolate was pure clade or pure circulating recombinant. After expansion in culture, the complete envelope (gp160) of each isolate was verified by sequencing. The 50% tissue culture infectious dose and p24 antigen concentration for each viral stock were determined; no correlation between these two biologic parameters was found. Syncytium formation in MT-2 cells and CCR5 or CXCR4 coreceptor usage were determined for all isolates. Isolates were also screened for neutralization by soluble CD4, a cocktail of monoclonal antibodies, and a pool of HIV-1-positive patient sera. The panel consists of 49 nonsyncytium-inducing isolates that use CCR5 as a major coreceptor and 11 syncytium-inducing isolates that use only CXCR4 or both coreceptors. Neutralization profiles suggest that the panel contains both neutralization-sensitive and -resistant isolates. This collection of HIV-1 isolates represents the six major globally prevalent strains, is exceptionally large and well characterized, and provides an important resource for standardization of immunogenicity assessment in HIV-1 vaccine trials.
Assuntos
Vacinas contra a AIDS/normas , Infecções por HIV/virologia , HIV-1/fisiologia , África , América , Anticorpos Monoclonais/imunologia , Anticorpos Monoclonais/farmacologia , Sudeste Asiático , Antígenos CD4/imunologia , Antígenos CD4/farmacologia , Células Cultivadas , Farmacorresistência Viral , Genoma Viral , Células Gigantes , Anticorpos Anti-HIV/imunologia , Anticorpos Anti-HIV/farmacologia , Proteína gp160 do Envelope de HIV/genética , Infecções por HIV/imunologia , HIV-1/efeitos dos fármacos , HIV-1/genética , Humanos , Soros Imunes/imunologia , Soros Imunes/farmacologia , Leucócitos Mononucleares , Dados de Sequência Molecular , Testes de Neutralização/normas , Filogenia , Receptores CCR5/metabolismo , Receptores CXCR4/metabolismo , VacinaçãoRESUMO
A number of human immunodeficiency virus type 1 (HIV-1) non-B-subtype products have been developed for present or future vaccine trials; in Thailand, several studies using subtype B and/or CRF01_AE vaccines have been conducted. To better characterize the biologic properties of these subtypes, 70 HIV-1 subtype B and E isolates were phenotyped as syncytium-inducing (SI) or non-syncytium-inducing (NSI) isolates and assessed for sensitivity to neutralizing antibody (NAb). A significantly higher number of NSI subtype E viruses were neutralization sensitive than SI subtype E viruses (P = 0.009), while no association between viral phenotype and sensitivity to NAb was observed for subtype B (P = 0.856), suggesting a difference in the neutralization patterns of subtypes B and E. Strikingly, concurrent CD4 T-cell numbers were significantly lower for subtype E-infected patients whose isolates were more resistant to NAb, both for the overall study group (P < 0.001) as well as for the 22 patients with NSI isolates (P = 0.013). Characterization of the evolution of biologic properties of both B and non-B HIV-1 subtypes will provide a clearer understanding of the repertoire of antibodies that must be elicited for a vaccine to be effective against all phenotypes and subtypes.