Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 129
Filtrar
1.
Eur Radiol ; 34(4): 2394-2404, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-37735276

RESUMO

OBJECTIVE: To characterize the use and impact of radiation dose reduction techniques in actual practice for routine abdomen CT. METHODS: We retrospectively analyzed consecutive routine abdomen CT scans in adults from a large dose registry, contributed by 95 hospitals and imaging facilities. Grouping exams into deciles by, first, patient size, and second, size-adjusted dose length product (DLP), we summarized dose and technical parameters and estimated which parameters contributed most to between-protocols dose variation. Lastly, we modeled the total population dose if all protocols with mean size-adjusted DLP above 433 or 645 mGy-cm were reduced to these thresholds. RESULTS: A total of 748,846 CTs were performed using 1033 unique protocols. When sorted by patient size, patients with larger abdominal diameters had increased dose and effective mAs (milliampere seconds), even after adjusting for patient size. When sorted by size-adjusted dose, patients in the highest versus the lowest decile in size-adjusted DLP received 6.4 times the average dose (1680 vs 265 mGy-cm) even though diameter was no different (312 vs 309 mm). Effective mAs was 2.1-fold higher, unadjusted CTDIvol 2.9-fold, and phase 2.5-fold for patients in the highest versus lowest size-adjusted DLP decile. There was virtually no change in kV (kilovolt). Automatic exposure control was widely used to modulate mAs, whereas kV modulation was rare. Phase was the strongest driver of between-protocols variation. Broad adoption of optimized protocols could result in total population dose reductions of 18.6-40%. CONCLUSION: There are large variations in radiation doses for routine abdomen CT unrelated to patient size. Modification of kV and single-phase scanning could result in substantial dose reduction. CLINICAL RELEVANCE: Radiation dose-optimization techniques for routine abdomen CT are routinely under-utilized leading to higher doses than needed. Greater modification of technical parameters and number of phases could result in substantial reduction in radiation exposure to patients. KEY POINTS: • Based on an analysis of 748,846 routine abdomen CT scans in adults, radiation doses varied tremendously across patients of the same size and optimization techniques were routinely under-utilized. • The difference in observed dose was due to variation in technical parameters and phase count. Automatic exposure control was commonly used to modify effective mAs, whereas kV was rarely adjusted for patient size. Routine abdomen CT should be performed using a single phase, yet multi-phase was common. • kV modulation by patient size and restriction to a single phase for routine abdomen indications could result in substantial reduction in radiation doses using well-established dose optimization approaches.


Assuntos
Exposição à Radiação , Tomografia Computadorizada por Raios X , Adulto , Humanos , Doses de Radiação , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Abdome
2.
Pediatr Radiol ; 53(2): 244-248, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36044052

RESUMO

BACKGROUND: Williams-Beuren syndrome is a rare multisystemic genetic disorder with an incidence of 1 in 7,500 live births. Because these children often have scoliosis, they undergo routine radiographic examinations of the spine. During these examinations we have found many children with supernumerary lumbar ribs arising from the first lumbar vertebra, often associated with lumbosacral transitional vertebrae. OBJECTIVE: To describe the incidence of supernumerary ribs and transitional vertebrae in children with Williams-Beuren syndrome and compare it to the incidence in a general population. Our hypothesis is that these findings are common, but they have not been described in the literature concerning Williams-Beuren syndrome. MATERIALS AND METHODS: From January 2015 to October 2021, 308 patients (138 male) with Williams-Beuren syndrome were treated at our hospital. Of these, 106 (47 male) underwent diagnostic imaging, mostly for suspected scoliosis. Panoramic radiographs of the whole spine were performed in 88 patients and radiographs of regions of the spine, chest radiographs, CT, MRI or fluoroscopy in 18 patients. We retrospectively analysed the images concerning the number of ribs and vertebrae. We correlated the frequency of lumbar ribs and transitional vertebrae in comparison to a general population as described in the literature. RESULTS: After exclusions for insufficient imaging, we analysed imaging in 91 patients. Of these, 67 patients (73.6%) had 13 ribs, of which 85% were located on both sides, 9% on the right and 6% on the left side. Of the 67 patients with supernumerary lumbar ribs, 38 (57%) also had transitional vertebrae. CONCLUSION: Supernumerary lumbar ribs arising from the first lumbar vertebra, often accompanied by lumbosacral transitional vertebrae, are common in children with Williams-Beuren syndrome.


Assuntos
Escoliose , Doenças Torácicas , Síndrome de Williams , Humanos , Masculino , Criança , Síndrome de Williams/diagnóstico por imagem , Escoliose/diagnóstico por imagem , Estudos Retrospectivos , Vértebras Lombares/diagnóstico por imagem , Costelas/diagnóstico por imagem
3.
Eur Radiol ; 32(3): 1971-1982, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34642811

RESUMO

OB JECTIVES: The European Society of Radiology identified 10 common indications for computed tomography (CT) as part of the European Study on Clinical Diagnostic Reference Levels (DRLs, EUCLID), to help standardize radiation doses. The objective of this study is to generate DRLs and median doses for these indications using data from the UCSF CT International Dose Registry. METHODS: Standardized data on 3.7 million CTs in adults were collected between 2016 and 2019 from 161 institutions across seven countries (United States of America (US), Switzerland, Netherlands, Germany, UK, Israel, Japan). DRLs (75th percentile) and median doses for volumetric CT-dose index (CTDIvol) and dose-length product (DLP) were assessed for each EUCLID category (chronic sinusitis, stroke, cervical spine trauma, coronary calcium scoring, lung cancer, pulmonary embolism, coronary CT angiography, hepatocellular carcinoma (HCC), colic/abdominal pain, appendicitis), and US radiation doses were compared with European. RESULTS: The number of CT scans within EUCLID categories ranged from 8,933 (HCC) to over 1.2 million (stroke). There was greater variation in dose between categories than within categories (p < .001), and doses were significantly different between categories within anatomic areas. DRLs and median doses were assessed for all categories. DRLs were higher in the US for 9 of the 10 indications (except chronic sinusitis) than in Europe but with a significantly higher sample size in the US. CONCLUSIONS: DRLs for CTDIvol and DLP for EUCLID clinical indications from diverse organizations were established and can contribute to dose optimization. These values were usually significantly higher in the US than in Europe. KEY POINTS: • Registry data were used to create benchmarks for 10 common indications for CT identified by the European Society of Radiology. • Observed US radiation doses were higher than European for 9 of 10 indications (except chronic sinusitis). • The presented diagnostic reference levels and median doses highlight potentially unnecessary variation in radiation dose.


Assuntos
Carcinoma Hepatocelular , Neoplasias Hepáticas , Adulto , Níveis de Referência de Diagnóstico , Humanos , Doses de Radiação , Valores de Referência , Sistema de Registros , Tomografia Computadorizada por Raios X
4.
Radiologe ; 62(2): 149-157, 2022 Feb.
Artigo em Alemão | MEDLINE | ID: mdl-35006315

RESUMO

BACKGROUND: Even after more than 100 years, the chest X­ray is still an important technique to detect important pathological changes of lungs, heart and vessels in a fast and low-dose manner. For the German-speaking regions, there are only recommendations available published by the "Ständigen Strahlenschutzkommission (SSK)" regarding the indication. These recommendations are not updated on a regular basis and more recent developments are only integrated with delayed. METHODS: The chest division of the German Radiological Society has summarized their expertise for the usage and indication of the chest X­ray. Especially within the field of oncology the usage of chest X­ray is evaluated differently to the aforementioned recommendations; here chest computed tomography (CT) is much more sensitive for evaluation of metastasis and local invasion of tumors. Also, within the area of infectious diseases in non-immunocompetent patients, CT is the method of choice. Based on the structure of the current recommendations, many current guidelines and indications are summarized and presented within the context of the usage of chest X­ray.


Assuntos
Radiologia , Humanos , Pulmão , Radiografia , Radiografia Torácica , Tomografia Computadorizada por Raios X , Raios X
5.
Eur Radiol ; 29(11): 6109-6118, 2019 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-31016447

RESUMO

OBJECTIVE: To compare the effect of contrast medium iodine concentration on contrast enhancement, heart rate, and injection pressure when injected at a constant iodine delivery rate in coronary CT angiography (CTA). METHODS: One thousand twenty-four patients scheduled for coronary CTA were prospectively randomized to receive one of four contrast media: iopromide 300 mg I/ml, iohexol 350 mg I/ml, iopromide 370 mg I/ml, or iomeprol 400 mg I/ml. Contrast media were delivered at an equivalent iodine delivery rate of 2.0 g I/s. Intracoronary attenuation was measured and compared (per vessel and per segment). Heart rate before and after contrast media injection was documented. Injection pressure was recorded (n = 403) during contrast medium injection and compared between groups. RESULTS: Intracoronary attenuation values were similar for the different contrast groups. The mean attenuation over all segments ranged between 384 HU for 350 mg I/ml and 395 HU for 400 mg I/ml (p = 0.079). Dose-length product (p = 0.8424), signal-to-noise ratio (all p > 0.05), time to peak (p = 0.324), and changes in heart rate (p = 0.974) were comparable between groups. The peak pressures differed: 197.4 psi for 300 mg I/ml (viscosity 4.6 mPa s), 229.8 psi for 350 mg I/ml (10.4 mPa s), 216.1 psi for 370 mg I/ml (9.5 mPa s), and 243.7 psi for 400 mg I/ml (12.6 mPa s) (p < 0.0001). CONCLUSION: Intravascular attenuation and changes in heart rate are independent of iodine concentration when contrast media are injected at the same iodine delivery rate. Differences in injection pressures are associated with the viscosity of the contrast media. KEY POINTS: • The contrast enhancement in coronary CT angiography is independent of the iodine concentration when contrast media are injected at body temperature (37 °C) with the same iodine delivery rate. • Iodine concentration does not influence the change in heart rate when contrast media are injected at identical iodine delivery rates. • For a fixed iodine delivery rate and contrast temperature, the viscosity of the contrast medium affects the injection pressure.


Assuntos
Angiografia por Tomografia Computadorizada/métodos , Meios de Contraste/farmacocinética , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico , Vasos Coronários/diagnóstico por imagem , Iodo/metabolismo , Iohexol/farmacocinética , Meios de Contraste/administração & dosagem , Doença da Artéria Coronariana/metabolismo , Feminino , Humanos , Injeções Intravenosas , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Iopamidol/administração & dosagem , Iopamidol/análogos & derivados , Iopamidol/farmacocinética , Masculino , Pessoa de Meia-Idade
6.
Eur Radiol ; 28(12): 5051-5059, 2018 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-29808430

RESUMO

OBJECTIVES: To compare contrast-to-noise ratios (CNRs) and iodine discrimination thresholds on iodine maps derived from dual energy CT (DECT) and subtraction CT (SCT). METHODS: A contrast-detail phantom experiment was performed with 2 to 15 mm diameter tubes containing water or iodinated contrast concentrations ranging from 0.5 mg/mL to 20 mg/mL. DECT scans were acquired at 100 kVp and at 140 kVp+Sn filtration. SCT scans were acquired at 100 kVp. Iodine maps were created by material decomposition (DECT) or by subtraction of water scans from iodine scans (SCT). Matched exposure levels varied from 8 to 15 mGy. Iodine discrimination thresholds (Cr) and response times were determined by eight observers. RESULTS: The adjusted mean CNR was 1.9 times higher for SCT than for DECT. Exposure level had no effect on CNR. All observers discriminated all details ≥10 mm at 12 and 15 mGy. For sub-centimetre details, the lowest calculated Cr was ≤ 0.50 mg/mL for SCT and 0.64 mg/mL for DECT. The smallest detail was discriminated at ≥4.4 mg/mL with SCT and at ≥7.4 mg/mL with DECT. Response times were lower for SCT than DECT. CONCLUSIONS: SCT results in higher CNR and reduced iodine discrimination thresholds compared to DECT for sub-centimetre details. KEY POINTS: • Subtraction CT iodine maps exhibit higher CNR than dual-energy iodine maps • Lower iodine concentrations can be discriminated for sub-cm details with SCT • Response times are lower using SCT compared to dual-energy CT.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton/métodos , Tomografia Computadorizada por Raios X/métodos , Meios de Contraste , Humanos , Iodo , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Razão Sinal-Ruído
7.
AJR Am J Roentgenol ; 210(5): W226-W233, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29570369

RESUMO

OBJECTIVE: Diagnostic reference levels (DRLs) are established for standard-sized patients; however, patient dose in CT depends on patient size. The purpose of this study was to introduce a method for setting size-dependent local diagnostic reference levels (LDRLs) and to evaluate these LDRLs in comparison with size-independent LDRLs and with respect to image quality. MATERIALS AND METHODS: One hundred eighty-four aortic CT angiography (CTA) examinations performed on either a second-generation or third-generation dual-source CT scanner were included; we refer to the second-generation dual-source CT scanner as "CT1" and the third-generation dual-source CT scanner as "CT2." The volume CT dose index (CTDIvol) and patient diameter (i.e., the water-equivalent diameter) were retrieved by dose-monitoring software. Size-dependent DRLs based on a linear regression of the CTDIvol versus patient size were set by scanner type. Size-independent DRLs were set by the 5th and 95th percentiles of the CTDIvol values. Objective image quality was assessed using the signal-to-noise ratio (SNR), and subjective image quality was assessed using a 4-point Likert scale. RESULTS: The CTDIvol depended on patient size and scanner type (R2 = 0.72 and 0.78, respectively; slope = 0.05 and 0.02 mGy/mm; p < 0.001). Of the outliers identified by size-independent DRLs, 30% (CT1) and 67% (CT2) were adequately dosed when considering patient size. Alternatively, 30% (CT1) and 70% (CT2) of the outliers found with size-dependent DRLs were not identified using size-independent DRLs. A negative correlation was found between SNR and CTDIvol (R2 = 0.36 for CT1 and 0.45 for CT2). However, all outliers had a subjective image quality score of sufficient or better. CONCLUSION: We introduce a method for setting size-dependent LDRLs in CTA. Size-dependent LDRLs are relevant for assessing the appropriateness of the radiation dose for an individual patient on a specific CT scanner.


Assuntos
Doenças da Aorta/diagnóstico por imagem , Tamanho Corporal , Angiografia por Tomografia Computadorizada/normas , Doses de Radiação , Artefatos , Angiografia por Tomografia Computadorizada/instrumentação , Meios de Contraste , Humanos , Iohexol/análogos & derivados , Valores de Referência , Razão Sinal-Ruído , Software
8.
Acta Oncol ; 56(11): 1591-1596, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28840770

RESUMO

BACKGROUND: Most solid tumors contain inadequately oxygenated (i.e., hypoxic) regions, which tend to be more aggressive and treatment resistant. Hypoxia PET allows visualization of hypoxia and may enable treatment adaptation. However, hypoxia PET imaging is expensive, time-consuming and not widely available. We aimed to predict hypoxia levels in non-small cell lung cancer (NSCLC) using more easily available imaging modalities: FDG-PET/CT and dynamic contrast-enhanced CT (DCE-CT). MATERIAL AND METHODS: For 34 NSCLC patients, included in two clinical trials, hypoxia HX4-PET/CT, planning FDG-PET/CT and DCE-CT scans were acquired before radiotherapy. Scans were non-rigidly registered to the planning CT. Tumor blood flow (BF) and blood volume (BV) were calculated by kinetic analysis of DCE-CT images. Within the gross tumor volume, independent clusters, i.e., supervoxels, were created based on FDG-PET/CT. For each supervoxel, tumor-to-background ratios (TBR) were calculated (median SUV/aorta SUVmean) for HX4-PET/CT and supervoxel features (median, SD, entropy) for the other modalities. Two random forest models (cross-validated: 10 folds, five repeats) were trained to predict the hypoxia TBR; one based on CT, FDG, BF and BV, and one with only CT and FDG features. Patients were split in a training (trial NCT01024829) and independent test set (trial NCT01210378). For each patient, predicted, and observed hypoxic volumes (HV) (TBR > 1.2) were compared. RESULTS: Fifteen patients (3291 supervoxels) were used for training and 19 patients (1502 supervoxels) for testing. The model with all features (RMSE training: 0.19 ± 0.01, test: 0.27) outperformed the model with only CT and FDG-PET features (RMSE training: 0.20 ± 0.01, test: 0.29). All tumors of the test set were correctly classified as normoxic or hypoxic (HV > 1 cm3) by the best performing model. CONCLUSIONS: We created a data-driven methodology to predict hypoxia levels and hypoxia spatial patterns using CT, FDG-PET and DCE-CT features in NSCLC. The model correctly classifies all tumors, and could therefore, aid tumor hypoxia classification and patient stratification.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/patologia , Meios de Contraste/metabolismo , Fluordesoxiglucose F18/metabolismo , Neoplasias Pulmonares/patologia , Tomografia por Emissão de Pósitrons/métodos , Tomografia Computadorizada por Raios X/métodos , Hipóxia Tumoral , Adenocarcinoma/diagnóstico por imagem , Adenocarcinoma/patologia , Idoso , Biomarcadores Tumorais/metabolismo , Carcinoma de Células Grandes/diagnóstico por imagem , Carcinoma de Células Grandes/patologia , Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Carcinoma de Células Escamosas/diagnóstico por imagem , Carcinoma de Células Escamosas/patologia , Feminino , Seguimentos , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Masculino , Imagem Multimodal/métodos , Prognóstico , Cintilografia/métodos , Compostos Radiofarmacêuticos/metabolismo
9.
Acta Oncol ; 56(11): 1544-1553, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28885084

RESUMO

BACKGROUND: Radiomic analyses of CT images provide prognostic information that can potentially be used for personalized treatment. However, heterogeneity of acquisition- and reconstruction protocols influences robustness of radiomic analyses. The aim of this study was to investigate the influence of different CT-scanners, slice thicknesses, exposures and gray-level discretization on radiomic feature values and their stability. MATERIAL AND METHODS: A texture phantom with ten different inserts was scanned on nine different CT-scanners with varying tube currents. Scans were reconstructed with 1.5 mm or 3 mm slice thickness. Image pre-processing comprised gray-level discretization in ten different bin widths ranging from 5 to 50 HU and different resampling methods (i.e., linear, cubic and nearest neighbor interpolation to 1 × 1 × 3 mm3 voxels) were investigated. Subsequently, 114 textural radiomic features were extracted from a 2.1 cm3 sphere in the center of each insert. The influence of slice thickness, exposure and bin width on feature values was investigated. Feature stability was assessed by calculating the concordance correlation coefficient (CCC) in a test-retest setting and for different combinations of scanners, tube currents and slice thicknesses. RESULTS: Bin width influenced feature values, but this only had a marginal effect on the total number of stable features (CCC > 0.85) when comparing different scanners, slice thicknesses or exposures. Most radiomic features were affected by slice thickness, but this effect could be reduced by resampling the CT-images before feature extraction. Statistics feature 'energy' was the most dependent on slice thickness. No clear correlation between feature values and exposures was observed. CONCLUSIONS: CT-scanner, slice thickness and bin width affected radiomic feature values, whereas no effect of exposure was observed. Optimization of gray-level discretization to potentially improve prognostic value can be performed without compromising feature stability. Resampling images prior to feature extraction decreases the variability of radiomic features.


Assuntos
Processamento de Imagem Assistida por Computador/métodos , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/métodos , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Humanos , Neoplasias Pulmonares/radioterapia
10.
Am J Ind Med ; 60(5): 422-431, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28370144

RESUMO

BACKGROUND: It has been suggested that asbestos exposure affects lung function, even in the absence of asbestos-related pulmonary interstitial or pleural changes or emphysema. METHODS: We analyzed associations between well-known asbestos-related risk factors, such as individual cumulative asbestos exposure, and key lung function parameters in formerly asbestos-exposed power industry workers (N = 207) with normal CT scans. For this, we excluded participants with emphysema, fibrosis, pleural changes, or any combination of these. RESULTS: The lung function parameters of FVC, FEV1, DLCO/VA, and airway resistance were significantly associated with the burden of smoking, BMI and years since end of exposure (only DLCO/VA). However, they were not affected by factors directly related to amount (eg, cumulative exposure) or duration of asbestos exposure. CONCLUSIONS: Our results confirm the well-known correlation between lung function, smoking habits, and BMI. However, we found no significant association between lung function and asbestos exposure.


Assuntos
Amianto/efeitos adversos , Pulmão/fisiopatologia , Exposição Ocupacional/efeitos adversos , Fumar/efeitos adversos , Adulto , Idoso , Análise de Variância , Índice de Massa Corporal , Poeira , Alemanha , Humanos , Masculino , Pessoa de Meia-Idade , Testes de Função Respiratória , Fatores de Risco , Abandono do Hábito de Fumar , Tomografia Computadorizada por Raios X , Capacidade Vital
11.
Am Heart J ; 177: 102-11, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-27297855

RESUMO

Management of patients with acute chest pain remains challenging. Cardiac biomarker testing reduces the likelihood of erroneously discharging patients with acute myocardial infarction (AMI). Despite normal contemporary troponins, physicians have still been reluctant to discharge patients without additional testing. Nowadays, the extremely high negative predictive value of current high-sensitivity cardiac troponin (hs-cTn) assays challenges this need. However, the decreased specificity of hs-cTn assays to diagnose AMI poses a new problem as noncoronary diseases (eg, pulmonary embolism, myocarditis, cardiomyopathies, hypertension, renal failure, etc) may also cause elevated hs-cTn levels. Subjecting patients with noncoronary diseases to unnecessary pharmacological therapy or invasive procedures must be prevented. Attempts to improve the positive predictive value to diagnose AMI by defining higher initial cutoff values or dynamic changes over time inherently lower the sensitivity of troponin assays. In this review, we anticipate a potential changing role of noninvasive imaging from ruling out myocardial disease when troponin values are normal toward characterizing myocardial disease when hs-cTn values are (mildly) abnormal.


Assuntos
Dor no Peito/diagnóstico por imagem , Doença da Artéria Coronariana/diagnóstico por imagem , Infarto do Miocárdio/diagnóstico por imagem , Troponina/sangue , Cardiomiopatias/sangue , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico por imagem , Dor no Peito/sangue , Dor no Peito/etiologia , Angiografia por Tomografia Computadorizada , Angiografia Coronária , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/complicações , Diagnóstico Diferencial , Ecocardiografia sob Estresse , Teste de Esforço , Humanos , Imageamento por Ressonância Magnética , Infarto do Miocárdio/sangue , Infarto do Miocárdio/complicações , Imagem de Perfusão do Miocárdio , Miocardite/sangue , Miocardite/complicações , Miocardite/diagnóstico por imagem , Embolia Pulmonar/sangue , Embolia Pulmonar/complicações , Embolia Pulmonar/diagnóstico por imagem , Sensibilidade e Especificidade , Tomografia Computadorizada de Emissão de Fóton Único
12.
Eur J Nucl Med Mol Imaging ; 43(2): 240-248, 2016 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-26338178

RESUMO

PURPOSE: Multiple imaging techniques are nowadays available for clinical in-vivo visualization of tumour biology. FDG PET/CT identifies increased tumour metabolism, hypoxia PET visualizes tumour oxygenation and dynamic contrast-enhanced (DCE) CT characterizes vasculature and morphology. We explored the relationships among these biological features in patients with non-small-cell lung cancer (NSCLC) at both the patient level and the tumour subvolume level. METHODS: A group of 14 NSCLC patients from two ongoing clinical trials (NCT01024829 and NCT01210378) were scanned using FDG PET/CT, HX4 PET/CT and DCE CT prior to chemoradiotherapy. Standardized uptake values (SUV) in the primary tumour were calculated for the FDG and hypoxia HX4 PET/CT scans. For hypoxia imaging, the hypoxic volume, fraction and tumour-to-blood ratio (TBR) were also defined. Blood flow and blood volume were obtained from DCE CT imaging. A tumour subvolume analysis was used to quantify the spatial overlap between subvolumes. RESULTS: At the patient level, negative correlations were observed between blood flow and the hypoxia parameters (TBR >1.2): hypoxic volume (-0.65, p = 0.014), hypoxic fraction (-0.60, p = 0.025) and TBR (-0.56, p = 0.042). At the tumour subvolume level, hypoxic and metabolically active subvolumes showed an overlap of 53 ± 36 %. Overlap between hypoxic sub-volumes and those with high blood flow and blood volume was smaller: 15 ± 17 % and 28 ± 28 %, respectively. Half of the patients showed a spatial mismatch (overlap <5 %) between increased blood flow and hypoxia. CONCLUSION: The biological imaging features defined in NSCLC tumours showed large interpatient and intratumour variability. There was overlap between hypoxic and metabolically active subvolumes in the majority of tumours, there was spatial mismatch between regions with high blood flow and those with increased hypoxia.


Assuntos
Carcinoma Pulmonar de Células não Pequenas/diagnóstico por imagem , Neoplasias Pulmonares/diagnóstico por imagem , Imagem Multimodal , Oxigênio/metabolismo , Tomografia por Emissão de Pósitrons , Tomografia Computadorizada por Raios X , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma Pulmonar de Células não Pequenas/patologia , Hipóxia Celular , Feminino , Fluordesoxiglucose F18 , Humanos , Neoplasias Pulmonares/metabolismo , Neoplasias Pulmonares/patologia , Masculino , Nitroimidazóis , Consumo de Oxigênio , Compostos Radiofarmacêuticos , Triazóis
13.
Eur Radiol ; 26(8): 2426-35, 2016 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26560728

RESUMO

PURPOSE: To evaluate image quality using reduced contrast media (CM) volume in pre-TAVI assessment. METHODS: Forty-seven consecutive patients referred for pre-TAVI examination were evaluated. Patients were divided into two groups: group 1 BMI < 28 kg/m(2) (n = 29); and group 2 BMI > 28 kg/m(2) (n = 18). Patients received a combined scan protocol: retrospective ECG-gated helical CTA of the aortic root (80kVp) followed by a high-pitch spiral CTA (group 1: 70 kV; group 2: 80 kVp) from aortic arch to femoral arteries. All patients received one bolus of CM (300 mgI/ml): group 1: volume = 40 ml; flow rate = 3 ml/s, group 2: volume = 53 ml; flow rate = 4 ml/s. Attenuation values (HU) and contrast-to-noise ratio (CNR) were measured at the levels of the aortic root (helical) and peripheral arteries (high-pitch). Diagnostic image quality was considered sufficient at attenuation values > 250HU and CNR > 10. RESULTS: Diagnostic image quality for TAVI measurements was obtained in 46 patients. Mean attenuation values and CNR (HU ± SD) at the aortic root (helical) were: group 1: 381 ± 65HU and 13 ± 8; group 2: 442 ± 68HU and 10 ± 5. At the peripheral arteries (high-pitch), mean values were: group 1: 430 ± 117HU and 11 ± 6; group 2: 389 ± 102HU and 13 ± 6. CONCLUSION: CM volume can be substantially reduced using low kVp protocols, while maintaining sufficient image quality for the evaluation of aortic root and peripheral access sites. KEY POINTS: • Image quality could be maintained using low kVp scan protocols. • Low kVp protocols reduce contrast media volume by 34-67 %. • Less contrast media volume lowers the risk of contrast-induced nephropathy.


Assuntos
Aorta/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Meios de Contraste/administração & dosagem , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos
14.
J Vasc Interv Radiol ; 27(4): 531-8, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26948327

RESUMO

PURPOSE: Ionizing radiation and iodinated contrast media are potential drawbacks to repetitive follow-up CT angiography in current practice. The aim of the present study was to optimize radiation dose and contrast agent volume by using individualized CT angiography protocols. MATERIALS AND METHODS: Eighty consecutive patients referred for CT angiography of the whole aorta were prospectively evaluated. Patients were divided into groups of patients with a body mass index (BMI) < 28 kg/m(2) (group 1; n = 50) and those with a BMI ≥ 28 kg/m(2) (group 2; n = 30). A control group consisted of 50 consecutive patients who were retrospectively evaluated. CT angiography parameters on a second-generation dual-source scanner were 128 × 0.6-mm collimation, pitch of 0.9, rotation time of 0.33 seconds, tube voltages of 80/100/120 kVp (group 1/group 2/control), reference tube current of 400 mA, and image reconstruction at 1-mm/0.8-mm slice thickness (kernels, B30f [control] and I30f/strength 3 [groups 1/2]). The control group received 120 mL of contrast agent (300 mgI/mL) at 4.8 mL/s; groups 1 and 2 received 44 mL and 53 mL at 3.3 mL/s and 4 mL/s, respectively. Effective dose was evaluated for each patient. Image quality was determined by qualitative image analysis at the levels of the thoracic, abdominal, and pelvic aorta as nondiagnostic, diagnostic, good, or excellent, and quantitative image analysis was performed, including attenuation values and contrast-to-noise ratio (CNR). RESULTS: Mean effective radiation dose values for CT angiography of the aorta were 3.7 mSv ± 0.7 in group 1, 6.7 mSv ± 1.4 in group 2, and 8.7 mSv ± 1.9 in the control group (P < .001). Mean attenuation values and CNR levels were 334 HU ± 66 and 16 ± 8, respectively, in group 1, 277 HU ± 56 and 14 ± 5 in group 2, and 305 HU ± 77 and 11 ± 4 in the control group. CONCLUSIONS: Iterative reconstruction algorithms resulted in 23%-57% less radiation in combination with 55%-63% less contrast agent volume compared with standard CT protocols.


Assuntos
Aorta/diagnóstico por imagem , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Idoso , Algoritmos , Meios de Contraste/administração & dosagem , Estudos de Viabilidade , Feminino , Humanos , Iohexol/administração & dosagem , Iohexol/análogos & derivados , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Prospectivos , Doses de Radiação , Exposição à Radiação , Interpretação de Imagem Radiográfica Assistida por Computador , Reprodutibilidade dos Testes , Estudos Retrospectivos , Razão Sinal-Ruído
15.
Acta Oncol ; 55(2): 156-62, 2016.
Artigo em Inglês | MEDLINE | ID: mdl-26399389

RESUMO

BACKGROUND AND PURPOSE: Prediction models for radiation-induced lung damage (RILD) are still unsatisfactory, with clinical toxicity endpoints that are difficult to quantify objectively. We therefore evaluated RILD more objectively, quantitatively and on a continuous scale measuring the lung tissue density changes per voxel. MATERIAL AND METHODS: Patients treated with radiotherapy (RT) alone, sequential and concurrent chemo-RT with and without the addition of cetuximab were studied. Follow-up computed tomography (CT) scans were co-registered using deformable registration to baseline CT scans. CT density changes were correlated to the RT dose delivered in every part of the lungs. RESULTS: One hundred and seventeen lung cancer patients were included. Mean dose to tumor was 60 Gy (range 45-79.2 Gy). Dose response curves showed a linear increase in the dose region between 0 and 65 Gy having a slope (based on coefficients of the multilevel model) expressed as a lung density increase per dose of 0.86 (95% CI 0.73-0.99), 1.31 (95% CI 1.19-1.43), 1.39 (95% CI 1.28-1.50) and 2.07 (95% CI 1.93-2.21) for patients treated only with RT (N=19), sequential chemo-RT (N=30), concurrent chemo-RT (N=49), and concurrent chemo-RT with cetuximab (N=19), respectively. CONCLUSIONS: CT density changes allow quantitative assessment of lung damage after fractionated RT, giving complementary information to standard used clinical endpoints. Patients receiving cetuximab showed a significantly larger dose response compared with other treatments.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias Pulmonares/tratamento farmacológico , Neoplasias Pulmonares/radioterapia , Pulmão/efeitos da radiação , Lesões por Radiação/patologia , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/tratamento farmacológico , Carcinoma Pulmonar de Células não Pequenas/patologia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Cetuximab/administração & dosagem , Cetuximab/uso terapêutico , Feminino , Seguimentos , Humanos , Pulmão/efeitos dos fármacos , Pulmão/patologia , Masculino , Pessoa de Meia-Idade , Dosagem Radioterapêutica , Radioterapia Conformacional/efeitos adversos , Carcinoma de Pequenas Células do Pulmão/tratamento farmacológico , Carcinoma de Pequenas Células do Pulmão/patologia , Carcinoma de Pequenas Células do Pulmão/radioterapia , Tomografia Computadorizada por Raios X
17.
Eur Radiol ; 25(7): 1975-83, 2015 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-25708961

RESUMO

OBJECTIVES: To determine the optimal imaging time point for transcatheter aortic valve implantation (TAVI) therapy planning by comprehensive evaluation of the aortic root. METHODS: Multidetector-row CT (MDCT) examination with retrospective ECG gating was retrospectively performed in 64 consecutive patients referred for pre-TAVI assessment. Eighteen different parameters of the aortic root were evaluated at 11 different time points in the cardiac cycle. Time points at which maximal (or minimal) sizes were determined, and dimension differences to other time points were evaluated. Theoretical prosthesis sizing based on different measurements was compared. RESULTS: Largest dimensions were found between 10 and 20% of the cardiac cycle for annular short diameter (10%); mean diameter (10%); effective diameter and circumference-derived diameter (20%); distance from the annulus to right coronary artery ostium (10%); aortic root at the left coronary artery level (20%); aortic root at the widest portion of coronary sinuses (20%); and right leaflet length (20%). Prosthesis size selection differed depending on the chosen measurements in 25-75% of cases. CONCLUSION: Significant changes in anatomical structures of the aortic root during the cardiac cycle are crucial for TAVI planning. Imaging in systole is mandatory to obtain maximal dimensions. KEY POINTS: • Most aortic root structures undergo significant dimensional changes throughout the cardiac cycle. • The largest dimensions of aortic parameters should be determined to optimize TAVI. • Circumference-derived diameter showed maximum dimension at 20% of the cardiac cycle.


Assuntos
Aorta Torácica/diagnóstico por imagem , Estenose da Valva Aórtica/diagnóstico por imagem , Substituição da Valva Aórtica Transcateter/métodos , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/patologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Tomografia Computadorizada Multidetectores/métodos , Tamanho do Órgão , Desenho de Prótese , Estudos Retrospectivos , Sístole
18.
J Endovasc Ther ; 22(6): 905-11, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26384397

RESUMO

PURPOSE: To assess and quantify the magnitude and direction of respiratory movement of the aorta and origins of its side branches. METHODS: A quantitative 3-dimensional (3D) subtraction analysis of computed tomography (CT) scans during inspiration and expiration was performed to determine the respiratory geometric movements of the aorta and side branches in 60 patients. During breath-hold expiration and inspiration, 1-mm-thick CT slices of the aorta were acquired in unenhanced and contrast-enhanced scans. The datasets were compared using dedicated multiplanar reformation image subtraction software to determine the change in position of relevant anatomic sections, including the ascending thoracic aorta (AA), the origins of the brachiocephalic artery (BA) and left subclavian artery (LSA), the descending thoracic aorta (DTA) at the level of the tenth thoracic vertebra, as well as the origins of the celiac trunk, superior mesenteric artery, and the renal arteries. RESULTS: Complex movement was visible during inspiration; the regions of interest in the thoracic aorta and side branches moved in the anterior, medial, and caudal directions compared with the expiration state. Mean 3D movement vectors (± standard deviation) were 8.9±3.6 mm (AA), 12.0±4.1 mm (BA), 11.1±3.9 mm (LSA), and 4.9±2.5 mm (DTA). Abdominal side branches moved in the caudal direction 1.3±1.1 mm. There was significantly less movement in the DTA compared to AA (p<0.001). The correlation coefficient between the extent of LSA movement and thoracic excursion was 0.78. CONCLUSION: The aorta and side branches undergo considerable respiratory movement. The results from this study provide an important contribution to understanding aortic dynamics.


Assuntos
Aorta Torácica/fisiologia , Respiração , Adulto , Idoso , Idoso de 80 Anos ou mais , Aorta Torácica/diagnóstico por imagem , Feminino , Humanos , Imageamento Tridimensional , Masculino , Pessoa de Meia-Idade , Movimento , Estudos Prospectivos , Tomografia Computadorizada por Raios X
19.
AJR Am J Roentgenol ; 205(6): 1332-8, 2015 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-26587942

RESUMO

OBJECTIVE: The purpose of this study was to systematically investigate radiation dose reduction using automated tube voltage selection during CT angiography (CTA) and to evaluate the impact of contrast medium (CM) injection protocols on dose reduction. MATERIALS AND METHODS: A circulation phantom containing the thoracic and abdominal vasculature was used. Four different concentrations of CM (iopromide 300 and 370 mg I/mL and iomeprol 350 and 400 mg I/mL) were administered while maintaining an identical iodine delivery rate (1.8 g I/s) and total iodine load (20.0 g). Three different scanning protocols for CTA of the thoracoabdominal aorta were used: protocol A, no dose modulation; protocol B, automated tube current modulation (CARE Dose4D); and protocol C, automated tube voltage selection (CARE kV). The dose-length product was recorded to calculate the effective dose. Attenuation values (in Hounsfield units), image noise levels, and signal-to-noise ratios (SNRs) in six predefined intravascular sites (three thoracic and three abdominal) were measured by two readers. All values were analyzed using the Kruskal-Wallis test and two-way ANOVA. RESULTS: There was a significant reduction in the effective dose (in millisieverts) for protocols B (mean ± SD, 2.03 ± 0.1 mSv) and C (1.00 ± 0.0 mSv) compared with protocol A (4.34 ± 0.0 mSv). The dose was reduced by 53% for protocol B and by 77% for protocol C. No significant differences were found in the effective dose among the different CM injection protocols within the scanning protocols; all p values were > 0.05. The attenuation values and SNRs were comparable among all the different CM injection protocols; all p values were > 0.05. CONCLUSION: A large radiation dose reduction (77%) can be achieved using automated tube voltage selection independent of the CM injection protocol.


Assuntos
Aortografia/métodos , Meios de Contraste/administração & dosagem , Iohexol/análogos & derivados , Iopamidol/análogos & derivados , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/métodos , Aortografia/instrumentação , Humanos , Iohexol/administração & dosagem , Iopamidol/administração & dosagem , Imagens de Fantasmas , Doses de Radiação , Tomografia Computadorizada por Raios X/instrumentação
20.
Radiology ; 273(3): 695-702, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25153157

RESUMO

PURPOSE: To determine the intervendor variability of Agatston scoring determined with state-of-the-art computed tomographic (CT) systems from the four major vendors in an ex vivo setup and to simulate the subsequent effects on cardiovascular risk reclassification in a large population-based cohort. MATERIALS AND METHODS: Research ethics board approval was not necessary because cadaveric hearts from individuals who donated their bodies to science were used. Agatston scores obtained with CT scanners from four different vendors were compared. Fifteen ex vivo human hearts were placed in a phantom resembling an average human adult. Hearts were scanned at equal radiation dose settings for the systems of all four vendors. Agatston scores were quantified semiautomatically with software used clinically. The ex vivo Agatston scores were used to simulate the effects of different CT scanners on reclassification of 432 individuals aged 55 years or older from a population-based study who were at intermediate cardiovascular risk based on Framingham risk scores. The Friedman test was used to evaluate overall differences, and post hoc analyses were performed by using the Wilcoxon signed-rank test with Bonferroni correction. RESULTS: Agatston scores differed substantially when CT scanners from different vendors were used, with median Agatston scores ranging from 332 (interquartile range, 114-1135) to 469 (interquartile range, 183-1381; P < .05). Simulation showed that these differences resulted in a change in cardiovascular risk classification in 0.5%-6.5% of individuals at intermediate risk when a CT scanner from a different vendor was used. CONCLUSION: Among individuals at intermediate cardiovascular risk, state-of the-art CT scanners made by different vendors produced substantially different Agatston scores, which can result in reclassification of patients to the high- or low-risk categories in up to 6.5% of cases.


Assuntos
Calcinose/classificação , Calcinose/diagnóstico por imagem , Doença das Coronárias/classificação , Doença das Coronárias/diagnóstico por imagem , Tomógrafos Computadorizados , Tomografia Computadorizada por Raios X/instrumentação , Cadáver , Humanos , Imagens de Fantasmas , Medição de Risco , Fatores de Risco
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA