Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 298
Filtrar
1.
Eur Heart J ; 45(13): 1116-1124, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38321820

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become a viable treatment option for patients with severe aortic valve stenosis across a broad range of surgical risk. The Nordic Aortic Valve Intervention (NOTION) trial was the first to randomize patients at lower surgical risk to TAVI or surgical aortic valve replacement (SAVR). The aim of the present study was to report clinical and bioprosthesis outcomes after 10 years. METHODS: The NOTION trial randomized 280 patients to TAVI with the self-expanding CoreValve (Medtronic Inc.) bioprosthesis (n = 145) or SAVR with a bioprosthesis (n = 135). The primary composite outcome was the risk of all-cause mortality, stroke, or myocardial infarction. Bioprosthetic valve dysfunction (BVD) was classified as structural valve deterioration (SVD), non-structural valve dysfunction (NSVD), clinical valve thrombosis, or endocarditis according to Valve Academic Research Consortium-3 criteria. Severe SVD was defined as (i) a transprosthetic gradient of 30 mmHg or more and an increase in transprosthetic gradient of 20 mmHg or more or (ii) severe new intraprosthetic regurgitation. Bioprosthetic valve failure (BVF) was defined as the composite rate of death from a valve-related cause or an unexplained death following the diagnosis of BVD, aortic valve re-intervention, or severe SVD. RESULTS: Baseline characteristics were similar between TAVI and SAVR: age 79.2 ± 4.9 years and 79.0 ± 4.7 years (P = .7), male 52.6% and 53.8% (P = .8), and Society of Thoracic Surgeons score < 4% of 83.4% and 80.0% (P = .5), respectively. After 10 years, the risk of the composite outcome all-cause mortality, stroke, or myocardial infarction was 65.5% after TAVI and 65.5% after SAVR [hazard ratio (HR) 1.0; 95% confidence interval (CI) 0.7-1.3; P = .9], with no difference for each individual outcome. Severe SVD had occurred in 1.5% and 10.0% (HR 0.2; 95% CI 0.04-0.7; P = .02) after TAVI and SAVR, respectively. The cumulative incidence for severe NSVD was 20.5% and 43.0% (P < .001) and for endocarditis 7.2% and 7.4% (P = 1.0) after TAVI and SAVR, respectively. No patients had clinical valve thrombosis. Bioprosthetic valve failure occurred in 9.7% of TAVI and 13.8% of SAVR patients (HR 0.7; 95% CI 0.4-1.5; P = .4). CONCLUSIONS: In patients with severe AS and lower surgical risk randomized to TAVI or SAVR, the risk of major clinical outcomes was not different 10 years after treatment. The risk of severe bioprosthesis SVD was lower after TAVR compared with SAVR, while the risk of BVF was similar.


Assuntos
Estenose da Valva Aórtica , Endocardite , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Infarto do Miocárdio , Acidente Vascular Cerebral , Trombose , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Resultado do Tratamento , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Infarto do Miocárdio/etiologia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Endocardite/cirurgia , Trombose/etiologia
2.
Eur Heart J ; 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38747246

RESUMO

BACKGROUND AND AIMS: Transcatheter aortic valve implantation (TAVI) has become the first choice to treat older patients with severe symptomatic aortic stenosis (AS). This study aimed to compare TAVI with surgery in low-risk patients ≤ 75 years of age, including both tricuspid and bicuspid AS. METHODS: The NOTION-2 trial enrolled and 1:1 randomized low-risk patients aged ≤ 75 years with severe symptomatic AS to TAVI or surgery. The primary endpoint was a composite of all-cause mortality, stroke or rehospitalization (related to the procedure, valve or heart failure) at 12 months. RESULTS: A total of 370 patients were enrolled with a mean age of 71.1 years and a median Society of Thoracic Surgeons risk score of 1.1%. A total of 100 patients had bicuspid AS. The 1-year incidence of the primary endpoint was 10.2% in the TAVI group and 7.1% in the surgery group (absolute risk difference 3.1%; 95% confidence interval [CI], -2.7% to 8.8%; hazard ratio (HR) 1.4, 95% CI: 0.7 to 2.9; p=0.3). Patients with TAVI, when compared to surgery, had lower risk of major bleeding and new-onset atrial fibrillation and higher risk of non-disabling stroke, permanent pacemaker implantation and moderate-or-greater paravalvular regurgitation. The risk of the primary composite endpoint was 8.7% and 8.3% in patients with tricuspid AS (HR 1.0, 95% CI: 0.5 to 2.3) and 14.3% and 3.9% in patients with bicuspid AS (HR 3.8, 95% CI: 0.8 to 18.5) treated with TAVI or surgery, respectively (P for interaction=0.1). CONCLUSIONS: Among low-risk patients aged ≤ 75 years with severe symptomatic AS, the rate of the composite of death, stroke, or rehospitalization at one year was similar between TAVI and surgery. TAVI outcomes in young bicuspid AS patients warrant caution and should be further investigated. (NOTION-2, ClinicalTrials.gov, NCT02825134).

3.
Catheter Cardiovasc Interv ; 103(5): 766-770, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38564317

RESUMO

BACKGROUND: Cardiac damage has gained increasing attention as a valid prognostic marker of mortality after transcatheter aortic valve replacement (TAVR). However, studies investigating the possible association between cardiac damage and hospitalization burden in TAVR patients are lacking. AIMS: This study aimed to investigate the impact of baseline cardiac damage on the hospitalization burden before, during, and after TAVR in an all-comers population. METHODS: All consecutive patients who underwent TAVR between 2016 and 2020 were included. Electronic medical records of all patients were examined to validate cardiovascular (CV) and heart failure (HF) related hospitalizations from 6 months before to 1 year after TAVR. Baseline cardiac damage was defined according to the staging classification by Généreux et al. RESULTS: Among 1397 TAVR patients, 94 (6.7%) had stage 0, 368 (26.4%) stage 1, 736 (52.7%) stage 2, 115 (8.2%) stage 3, and 84 (6.0%) stage 4 cardiac damage. Patients with more advanced cardiac damage at baseline had more HF hospitalizations within 6 months before TAVR (p < 0.01) and with a longer length of stay (LoS) (p < 0.01). Regarding the index TAVR admission, there was no difference in procedure time (p = 0.26) or LoS (p = 0.18) between groups. Still, TAVR patients with more advanced baseline cardiac damage had a higher risk of CV and HF rehospitalization after TAVR (p < 0.05). CONCLUSIONS: Baseline cardiac damage in patients undergoing TAVR has an impact on the pre- and post-procedural cardiovascular hospitalization burden. However, the cardiac damage status does not affect the TAVR procedure time or index TAVR admission length of stay.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Resultado do Tratamento , Hospitalização , Tempo de Internação , Fatores de Risco , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia
4.
Artigo em Inglês | MEDLINE | ID: mdl-38764320

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.

5.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36883599

RESUMO

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Prognóstico , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia
6.
N Engl J Med ; 382(2): 130-139, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733182

RESUMO

BACKGROUND: Subclinical leaflet thickening and reduced leaflet motion of bioprosthetic aortic valves have been documented by four-dimensional computed tomography (CT). Whether anticoagulation can reduce these phenomena after transcatheter aortic-valve replacement (TAVR) is not known. METHODS: In a substudy of a large randomized trial, we randomly assigned patients who had undergone successful TAVR and who did not have an indication for long-term anticoagulation to a rivaroxaban-based antithrombotic strategy (rivaroxaban [10 mg] plus aspirin [75 to 100 mg] once daily) or an antiplatelet-based strategy (clopidogrel [75 mg] plus aspirin [75 to 100 mg] once daily). Patients underwent evaluation by four-dimensional CT at a mean (±SD) of 90±15 days after randomization. The primary end point was the percentage of patients with at least one prosthetic valve leaflet with grade 3 or higher motion reduction (i.e., involving >50% of the leaflet). Leaflet thickening was also assessed. RESULTS: A total of 231 patients were enrolled. At least one prosthetic valve leaflet with grade 3 or higher motion reduction was found in 2 of 97 patients (2.1%) who had scans that could be evaluated in the rivaroxaban group, as compared with 11 of 101 (10.9%) in the antiplatelet group (difference, -8.8 percentage points; 95% confidence interval [CI], -16.5 to -1.9; P = 0.01). Thickening of at least one leaflet was observed in 12 of 97 patients (12.4%) in the rivaroxaban group and in 33 of 102 (32.4%) in the antiplatelet group (difference, -20.0 percentage points; 95% CI, -30.9 to -8.5). In the main trial, the risk of death or thromboembolic events and the risk of life-threatening, disabling, or major bleeding were higher with rivaroxaban (hazard ratios of 1.35 and 1.50, respectively). CONCLUSIONS: In a substudy of a trial involving patients without an indication for long-term anticoagulation who had undergone successful TAVR, a rivaroxaban-based antithrombotic strategy was more effective than an antiplatelet-based strategy in preventing subclinical leaflet-motion abnormalities. However, in the main trial, the rivaroxaban-based strategy was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than the antiplatelet-based strategy. (Funded by Bayer; GALILEO-4D ClinicalTrials.gov number, NCT02833948.).


Assuntos
Valva Aórtica/fisiopatologia , Aspirina/farmacologia , Clopidogrel/farmacologia , Inibidores do Fator Xa/farmacologia , Próteses Valvulares Cardíacas , Inibidores da Agregação Plaquetária/farmacologia , Rivaroxabana/farmacologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/efeitos dos fármacos , Valva Aórtica/patologia , Aspirina/efeitos adversos , Aspirina/uso terapêutico , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Clopidogrel/uso terapêutico , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/uso terapêutico , Feminino , Tomografia Computadorizada Quadridimensional , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/efeitos adversos , Rivaroxabana/uso terapêutico , Tromboembolia/etiologia , Tromboembolia/mortalidade
7.
N Engl J Med ; 382(2): 120-129, 2020 01 09.
Artigo em Inglês | MEDLINE | ID: mdl-31733180

RESUMO

BACKGROUND: Whether the direct factor Xa inhibitor rivaroxaban can prevent thromboembolic events after transcatheter aortic-valve replacement (TAVR) is unclear. METHODS: We randomly assigned 1644 patients without an established indication for oral anticoagulation after successful TAVR to receive rivaroxaban at a dose of 10 mg daily (with aspirin at a dose of 75 to 100 mg daily for the first 3 months) (rivaroxaban group) or aspirin at a dose of 75 to 100 mg daily (with clopidogrel at a dose of 75 mg daily for the first 3 months) (antiplatelet group). The primary efficacy outcome was the composite of death or thromboembolic events. The primary safety outcome was major, disabling, or life-threatening bleeding. The trial was terminated prematurely by the data and safety monitoring board because of safety concerns. RESULTS: After a median of 17 months, death or a first thromboembolic event (intention-to-treat analysis) had occurred in 105 patients in the rivaroxaban group and in 78 patients in the antiplatelet group (incidence rates, 9.8 and 7.2 per 100 person-years, respectively; hazard ratio with rivaroxaban, 1.35; 95% confidence interval [CI], 1.01 to 1.81; P = 0.04). Major, disabling, or life-threatening bleeding (intention-to-treat analysis) had occurred in 46 and 31 patients, respectively (4.3 and 2.8 per 100 person-years; hazard ratio, 1.50; 95% CI, 0.95 to 2.37; P = 0.08). A total of 64 deaths occurred in the rivaroxaban group and 38 in the antiplatelet group (5.8 and 3.4 per 100 person-years, respectively; hazard ratio, 1.69; 95% CI, 1.13 to 2.53). CONCLUSIONS: In patients without an established indication for oral anticoagulation after successful TAVR, a treatment strategy including rivaroxaban at a dose of 10 mg daily was associated with a higher risk of death or thromboembolic complications and a higher risk of bleeding than an antiplatelet-based strategy. (Funded by Bayer and Janssen Pharmaceuticals; GALILEO ClinicalTrials.gov number, NCT02556203.).


Assuntos
Aspirina/uso terapêutico , Clopidogrel/uso terapêutico , Inibidores do Fator Xa/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Rivaroxabana/uso terapêutico , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Aspirina/efeitos adversos , Fibrilação Atrial/tratamento farmacológico , Doenças Cardiovasculares/mortalidade , Clopidogrel/efeitos adversos , Quimioterapia Combinada , Inibidores do Fator Xa/efeitos adversos , Feminino , Próteses Valvulares Cardíacas , Hemorragia/induzido quimicamente , Humanos , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Rivaroxabana/efeitos adversos , Tromboembolia/mortalidade
8.
Am Heart J ; 264: 183-189, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37178995

RESUMO

BACKGROUND: Valve-in-valve-transcatheter aortic valve implantation (TAVI) is a feasible and increasingly used treatment option for failed surgical aortic prosthesis, but data from clinical practice are limited. We aimed to examine patient characteristics and outcomes of patients undergoing TAVI in a surgival valve (valve-in-valve TAVI) compared with patients undergoing TAVI in a native valve. METHODS: Using nationwide registries, we identified all Danish citizens, who underwent TAVI from January 1, 2008, to December 31, 2020. RESULTS: A total of 6,070 patients undergoing TAVI were identified; 247 (4%) patients had a history of SAVR (The valve-in-valve cohort). The median age of the study population was 81 (25th-75th percentile 77-85) and 55% were men. Patients with valve-in-valve-TAVI were younger but had a greater burden of cardiovascular comorbidities compared with patients with native-valve-TAVI. Within 30 days post procedure, 11 (0.2%) and 748 (13.8%) patients who underwent valve-in-valve-TAVI and native-valve-TAVI, respectively, had a pacemaker implantation. The cumulative 30-day risk of death among patients with valve-in-valve-TAVI was 2.4% (95% CI: 1.0%-5.0%) and 2.7% (95% CI: 2.3%-3.1%) in patients with native-valve-TAVI, respectively. Correspondingly, the cumulative 5-year risk of death was 42.5% (95% CI: 34.2%-50.6%) and 44.8% (95% CI: 43.2%-46.4%), respectively. In multivariable Cox proportional hazard analysis, valve-in-valve-TAVI was not associated with a significantly different risk of death at 30 days (Hazard ratio (HR) = 0.95, 95% CI 0.41-2.19) and 5 years (HR = 0.79, 95% CI 0.62-1.00) post-TAVI compared with native-valve-TAVI. CONCLUSIONS: TAVI in a failed surgical aortic prosthesis as compared to TAVI in a native valve, was not associated with significantly different short- and long-term mortality, suggesting that valve-in-valve-TAVI is a safe procedure.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco , Próteses e Implantes , Dinamarca/epidemiologia , Valva Aórtica/cirurgia , Resultado do Tratamento
9.
Am Heart J ; 255: 39-51, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36220354

RESUMO

BACKGROUND: Coronary artery disease (CAD) frequently coexists with severe aortic valve stenosis (AS) in patients planned for transcatheter aortic valve implantation (TAVI). How to manage CAD in this patient population is still an unresolved question. In particular, it is still not known whether fractional flow reserve (FFR) guided revascularization with percutaneous coronary intervention (PCI) is superior to medical treatment for CAD in terms of clinical outcomes. STUDY DESIGN: The third Nordic Aortic Valve Intervention (NOTION-3) Trial is an open-label investigator-initiated, multicenter multinational trial planned to randomize 452 patients with severe AS and significant CAD to either FFR-guided PCI or medical treatment, in addition to TAVI. Patients are eligible for the study in the presence of at least 1 significant PCI-eligible coronary stenosis. A significant stenosis is defined as either FFR ≤0.80 and/or diameter stenosis >90%. The primary end point is a composite of first occurring all-cause mortality, myocardial infarction, or urgent revascularization (PCI or coronary artery bypass graft performed during unplanned hospital admission) until the last included patient have been followed for 1 year after the TAVI. SUMMARY: NOTION-3 is a multicenter, multinational randomized trial aiming at comparing FFR-guided revascularization vs medical treatment of CAD in patients with severe AS planned for TAVI.


Assuntos
Estenose da Valva Aórtica , Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Intervenção Coronária Percutânea/efeitos adversos , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/cirurgia , Valva Aórtica/cirurgia , Constrição Patológica , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Angiografia Coronária
10.
Catheter Cardiovasc Interv ; 102(1): 155-158, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37210620

RESUMO

A 70-year-old man with history of transcatheter aortic valve-in-valve implantation was admitted because of suspected infective endocarditis (IE). Transesophageal echocardiogram did not reveal any vegetations, as the metallic stent frames caused significant artifacts. Position emission tomography was also negative. Intracardiac echocardiogram (ICE) was performed retrogradely through the ascending aorta, which showed clear vegetations over the stent frame of the transcatheter heart valve. Endocarditis after transcatheter aortic valve implantation was not uncommon. With increasing use of valve-in-valve procedures, echocardiographic diagnosis of IE would be more challenging. This case demonstrated the advantage of ICE over conventional echocardiography in visualizing the neo-aortic valve complex for diagnosing IE.


Assuntos
Endocardite Bacteriana , Endocardite , Infecções Relacionadas à Prótese , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/terapia , Resultado do Tratamento , Endocardite Bacteriana/diagnóstico por imagem , Endocardite Bacteriana/etiologia , Endocardite Bacteriana/cirurgia , Endocardite/etiologia , Endocardite/complicações , Substituição da Valva Aórtica Transcateter/efeitos adversos , Ecocardiografia/efeitos adversos
11.
Catheter Cardiovasc Interv ; 101(3): 655-659, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36651342

RESUMO

Valve-in-valve transcatheter aortic valve replacement (VIV-TAVR) for a degenerated surgical aortic bioprosthesis is a well-established treatment modality but carries an increased risk of coronary artery obstruction (CAO) with potentially catastrophic consequences. Both chimney stenting and leaflet modification by BASILICA (Bioprosthetic or Native Aortic Scallop Intentional Laceration to Prevent Iatrogenic Coronary Obstruction) are increasingly employed and can be highly effective means of preventing CAO. Using a case report, in which both strategies were utilized, as a platform for detailed discussion, we address the indications, contraindications, and relative merits of each technique in the prevention of CAO.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Oclusão Coronária , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Vasos Coronários/cirurgia , Desenho de Prótese , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Oclusão Coronária/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/etiologia
12.
Circulation ; 143(2): 104-116, 2021 01 12.
Artigo em Inglês | MEDLINE | ID: mdl-32975133

RESUMO

BACKGROUND: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. METHODS: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. RESULTS: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76-996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510-1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR (P<0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients (P=0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P<0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P=0.02). The rates of Mitral Valve Academic Research Consortium-defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P=0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74-12.56; P=0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88-21.53; P<0.001) were both independently associated with repeat mitral valve replacement. CONCLUSIONS: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.


Assuntos
Doenças das Valvas Cardíacas/cirurgia , Próteses Valvulares Cardíacas/normas , Valva Mitral/cirurgia , Sistema de Registros , Reoperação/normas , Substituição da Valva Aórtica Transcateter/normas , Idoso , Idoso de 80 Anos ou mais , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Próteses Valvulares Cardíacas/tendências , Implante de Prótese de Valva Cardíaca/métodos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Internacionalidade , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Reoperação/tendências , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/tendências
13.
Catheter Cardiovasc Interv ; 100(5): 795-800, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35880854

RESUMO

OBJECTIVES: This study aimed to assess the rate of difficult interatrial septum (IAS) crossing with the intracardiac echocardiography (ICE) probe during percutaneous left atrial appendage (LAA) closure and to identify techniques that facilitate IAS crossing with the ICE probe. BACKGROUND: Percutaneous LAA closure is increasingly performed by ICE guidance. Although such an approach omits the need for general anesthesia, crossing of the IAS with the ICE probe may sometimes be challenging. METHODS: All consecutive patients that underwent ICE-guided percutaneous LAA closure with an Amplatzer Amulet (Abbott) or WatchmanFLX (Boston Scientific) at our center in the period 2018-2021 were included. Cases in which IAS crossing with ICE was difficult were identified and techniques used to facilitate IAS crossing were identified and listed. RESULTS: In 17 (5%) out of 354 cases, IAS crossing with the ICE probe was difficult and required use of additional techniques. Ultimately, IAS crossing was also successful in these 17 cases by using one of three possible facilitation techniques: the probing technique (12 cases), the double-wire technique (3 cases), and the snaring technique (2 cases). In one case, the double-wire technique was converted to the snaring technique, as crossing of the ICE probe remained challenging despite the use of two stiff guidewires. CONCLUSION: Crossing of the IAS with the ICE probe can be challenging in 5% of ICE-guided percutaneous LAA closure procedures. Operators should be aware of possible facilitation techniques in challenging cases, as these show to be safe and effective.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Ecocardiografia Transesofagiana , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Ultrassonografia de Intervenção/métodos , Resultado do Tratamento
14.
Artigo em Inglês | MEDLINE | ID: mdl-36542648

RESUMO

BACKGROUND: Use of a right-left (R-L) cusp overlap view for transcatheter aortic valve replacement (TAVR) with self-expanding valves has recently been proposed aiming to reduce permanent pacemaker implantation (PPMI). An objective, data-driven explanation for this observation is missing. AIMS: To assess the impact of different implantation techniques on the risk of PPMI following TAVR with the Portico/NavitorTM transcatheter heart valve (THV; Abbott). METHODS: A TAVR-population treated with Portico/NavitorTM had the THV implanted in a right versus left anterior oblique (RAO/LAO) fluoroscopic view with no parallax in the delivery system. The impact of these different implantation views on the spatial relationship between THV and native aortic annulus and the risk of conduction disturbances and PPMI after TAVR was studied. RESULTS: A total of 366 matched TAVR patients were studied: 183 in the RAO group and 183 in the LAO group. The degree of aortic annulus plane tilt was significantly smaller in the RAO versus LAO group (median: 0° vs. 23°, p < 0.001), with no plane tilt in 105 out of 183 cases (57.3%) in the RAO group. At 30 days after TAVR, the overall PPMI and guideline-directed PPMI rates were 12.6% versus 18.0% (p = 0.15) and 8.2% versus 15.3% (p = 0.04) in the RAO versus LAO group, respectively. CONCLUSIONS: Use of a R-L cusp overlap (RAO-caudal) view for implantation of the Portico/NavitorTM valve results in less tilt of the native aortic annulus plane and a clear trend toward a lower 30-day PPMI rate as compared to TAVR using the conventional LAO implantation view.

15.
Catheter Cardiovasc Interv ; 100(4): 636-645, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-36040717

RESUMO

BACKGROUND: Midterm data comparing clinical outcomes after successful implantation of self-expanding and balloon-expandable transcatheter heart valves (THV) are limited. We aimed to compare 2-year outcomes after successful transcatheter aortic valve implantation (TAVI) with the Edwards balloon-expandable or the Medtronic self-expanding THV. METHODS: Two-year outcomes were analyzed according to the implanted THV in the GALILEO trial. Major adverse cardiac and cerebrovascular events (MACCE) was a composite of all-cause death or thromboembolic events including stroke, myocardial infarction, symptomatic valve thrombosis, systemic embolism, deep-vein thrombosis, or pulmonary embolism. RESULTS: Among 1644 patients recruited in 136 centers across 16 countries between 2015 and 2018, 499 received a self-expanding and 757 patients received a balloon-expandable THV. Patients treated with a self-expanding THV were more likely to be female, and had higher surgical risk, lower hemoglobin levels, and more frequent valve-in-valve procedures than those with a balloon-expandable THV. After multivariable adjustment, there were no significant differences in major clinical outcomes between self-expanding versus balloon-expandable THV: MACCE (17.0% vs. 13.4%, adjusted-hazard ratios [HR] 1.18, 95% confidence intervals [CI]: 0.82-1.69); all-cause death (11.4% vs. 9.3%, adjusted-HR 1.26; 95% CI: 0.78-2.05); cardiovascular death (8.5% vs. 4.0%, adjusted-HR 1.53; 95% CI: 0.82-2.86), any stroke (5.1% vs. 3.7%, adjusted-HR 0.86; 95% CI: 0.43-1.73); major or life-threatening bleeding (5.9% vs. 6.8%, adjusted-HR 0.93; 95% CI: 0.53-1.63). CLINICAL TRIAL REGISTRATION: https://www. CLINICALTRIALS: gov. NCT02556203. CONCLUSIONS: Two-year follow-up data from the GALILEO trial indicate that successful TAVI either with self-expanding or balloon-expandable THVs according to physician discretion did not show difference in rates of MACCE.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Acidente Vascular Cerebral , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Hemoglobinas , Humanos , Masculino , Desenho de Prótese , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
16.
J Interv Cardiol ; 2022: 9899235, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35250395

RESUMO

Bioprosthetic surgical aortic valve failure requiring reintervention is a frequent clinical problem with event rates up to 20% at 10 years after surgery. Transcatheter aortic valve-in-valve implantation (ViV-TAVI) has become a valuable treatment option for these patients, although it requires careful procedural planning. We here describe and illustrate a stepwise approach to plan and perform ViV-TAVI and discuss preprocedural computerized tomography planning, transcatheter heart valve selection, and implantation techniques. Particular attention is paid to coronary artery protection and the possible need for bioprosthetic valve fracture since patients with small surgical aortic bioprostheses are at a risk of high residual gradients after ViV-TAVI. Considering updated clinical data on long-term outcomes following ViV-TAVI, this approach may become the default treatment strategy for patients with a failing surgical aortic bioprosthesis.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Desenho de Prótese , Falha de Prótese , Instrumentos Cirúrgicos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 97(5): E736-E738, 2021 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-32621567

RESUMO

Aortic annulus rupture or aortic root perforation is a rare complication of transcatheter aortic valve replacement (TAVR), requiring emergent cardiac surgery and carrying a high intraoperative mortality. Few cases can be managed conservatively, provided a strict clinical follow-up. This study describes the case of a 78-year-old patient with a degenerated bicuspid aortic valve stenosis who presented with a late aortic root perforation following TAVR, which was successfully managed applying a "watchful waiting" approach. Cardiac computed tomography imaging played a pivotal role in the diagnosis and subsequent decision on treatment and clinical follow-up.


Assuntos
Falso Aneurisma , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Trombose , Substituição da Valva Aórtica Transcateter , Idoso , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Tomografia Computadorizada Multidetectores , Trombose/diagnóstico por imagem , Trombose/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 97(7): E1011-E1018, 2021 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-33034944

RESUMO

OBJECTIVES: This study aimed to present a new approach of thorough preclinical testing of a novel left atrial appendage (LAA) occluder device. BACKGROUND: The development of a safe and effective LAA occluder has been shown to be challenging. METHODS: The novel OMEGATM LAA occluder (Eclipse Medical, Ireland) was tested in a porcine model and three-dimensional (3D) human LAA models - this as a prelude to its first-in-human use. RESULTS: In a first series of in-vivo experiments, the OMEGATM LAA occluder was shown to have a satisfactory device biocompatibility in a porcine model. The design of the OMEGATM device was further refined and optimized following three more series of in-vivo experiments. The second generation OMEGATM device was designed with thinner wires, leading to a profile reduction. Based on in-vitro testing of different OMEGATM device sizes implanted at different depths in human three-dimensional (3D) LAA models, it could be determined that (1) the landing zone should be measured at a median depth of 12 mm from the LAA ostium; (2) the distal self-retaining inverted cup should have 10%-25% compression to minimize device embolization risk; and (3) the disc should be slightly inverted, i.e. pulled into the LAA, to promote complete LAA occlusion. The combined in-vivo and in-vitro testing resulted in an optimized pre-procedural planning of the first-in-human case treated with the OMEGATM device. CONCLUSIONS: This series of carefully planned in-vivo and in-vitro experiments allowed demonstration of the safety and efficacy of the OMEGATM LAA occluder. This approach of thorough preclinical testing of medical devices may reduce the risk of complications in first-in-human cases and may become the standard approach for device development and preclinical testing in the future.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Animais , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Transesofagiana , Humanos , Suínos , Resultado do Tratamento
19.
Catheter Cardiovasc Interv ; 97(3): E418-E424, 2021 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-32609437

RESUMO

OBJECTIVES: This study aimed to assess the feasibility and safety of conducting an entire transcatheter aortic valve replacement (TAVR) program by using percutaneous techniques only. BACKGROUND: Surgically assisted transthoracic TAVR has been reported to be associated with more complications and longer hospital stays. METHODS: During 2019, all TAVR at a single center were performed by standard transfemoral (TF), intravascular lithotripsy-assisted TF, transaxillary (TAx), or transcaval approach using percutaneous techniques only. No patients were denied TAVR because of access. Procedural and clinical endpoints were categorized using Valve Academic Research Consortium-2 criteria. RESULTS: In total, 306 consecutive TAVR patients were enrolled (mean age 78.9 ± 7.2 years). Most patients were treated by TF approach (94.8%)-of these, nine (2.9%) were pre-treated with intravascular lithotripsy. A percutaneous TAx and transcaval approach were used in 12 (3.9%) and four patients (1.3%), respectively. There were no procedural deaths and one peri-procedural stroke. Valve performance was satisfying in 298 patients (97.4%); six patients had a moderate aortic regurgitation and two patients had a mean gradient ≥20 mmHg following valve-in-valve procedure. The 30-day major vascular complication and major bleeding rate was 2.3% and 3.9%, respectively. A new permanent pacemaker was implanted in 41 patients (13.4%). Of all patients, 81% were discharged within two days post-TAVR, including 11 out of 12 TAx patients and all transcaval cases. CONCLUSIONS: A fully percutaneous TAVR program is feasible and safe with favorable immediate and early clinical outcomes and allowing a short hospital stay.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estudos de Viabilidade , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
20.
Catheter Cardiovasc Interv ; 98(3): E420-E426, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33220011

RESUMO

OBJECTIVES: This study aimed to find imaging risk features for device related-pulmonary artery (PA) injury (DR-PAI) in patients after left atrial appendage closure (LAAC). BACKGROUND: Cardiac tamponade resulting from DR-PAI is a rare but life-threatening complication of LAAC. METHODS: In vitro analysis of Amplatzer™ Amulet™ (Abbott, MN) device was done. Measurements of the distance between PA and Amplatzer lobe at its middle part, distal part, and along the stabilizing wires' trajectory (wires-to-PA distance) were taken in 100 consecutive patients on post-LAAC computed tomography (CT) studies. Clinical outcomes were collected. RESULTS: In vitro analysis indicated that both middle and distal lobe had to be in close PA proximity (<1.5 mm) for the stabilizing wires to cause risk for DR-PAI, configuration called ''cuddling lobe orientation''. On CT measurements middle lobe-PA distance was 4.7 mm (IQR = 2.7-9.5), with close proximity in 4 (4%) patients, and distal lobe-PA distance was 3.2 mm (IQR = 1.8-7.2 mm), with close proximity in 17 (17%) patients. Stabilizing wires were pointing toward PA in 47 patients (47%) with median wire-to-PA distance 5.7 mm (IQR = 3.6-8.5 mm). ''Cuddling'' was found in 2 (2%) patients and resulted in shorter wires-to-PA distance vs no ''cuddling'' group (2.3 vs 5.8 mm p <.01). At 2.9 ± 1.0 yrs of follow-up, the two patients with ''cuddling lobe orientation'' on post-LAAC CT scan developed late cardiac tamponades (p <.001). One of those required surgery, which confirmed DR-PAI. CONCLUSIONS: ''Cuddling lobe orientation'' of Amulet device with the PA was associated with short wires-to-PA distance and late pericardial effusions, including DR-PAI. Hence, such device-to-PA configuration should be avoided.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Humanos , Artéria Pulmonar/diagnóstico por imagem , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA