Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 108
Filtrar
1.
Am Heart J ; 2024 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-38838970

RESUMO

BACKGROUND: The impact of prosthesis-patient mismatch (PPM) on major endpoints after transcatheter aortic valve replacement (TAVR) is controversial and the effects on progression of heart damage are poorly investigated. Therefore, our study aims to evaluate the prevalence and predictors of PPM in a "real world" cohort of patients at intermediate and low surgical risk, its impact on mortality and the clinical-echocardiographic progression of heart damage. METHODS: 963 patients who underwent TAVR procedure between 2017 and 2021, from the RECOVERY-TAVR international multicenter observational registry, were included in this analysis. Multiparametric echocardiographic data of these patients were analyzed at 1-year follow-up (FU). Clinical and echocardiographic features were stratified by presence of PPM and PPM severity, as per the most current international recommendations, using VARC-3 criteria. RESULTS: 18% of patients developed post-TAVR. PPM, and 7.7% of the whole cohort had severe PPM. At baseline, 50.3% of patients with PPM were male (vs 46.2% in the cohort without PPM, p=0.33), aged 82 (IQR 79-85y) years vs 82 (IQR 78-86 p=0.46), and 55.6% had Balloon-Expandable valves implanted (vs 46.8% of patients without PPM, p=0.04); they had smaller left ventricular outflow tract (LVOT) diameter (20 mm, IQR 19-21 vs 20 mm, IQR 20-22, p=0.02), reduced SVi (34.2 vs 38 ml/m2, p<0.01) and transaortic flow rate (190.6 vs 211 ml/s, p<0.01). At pre-discharge FU patients with PPM had more paravalvular aortic regurgitation (moderate-severe AR 15.8% vs 9.2%, p<0.01). At 1-year FU, maladaptive alterations of left ventricular parameters were found in patients with PPM, with a significant increase in end-systolic diameter (33 mm vs 28 mm, p=0.03) and a significant increase in left ventricle end systolic indexed volume in those with moderate and severe PPM (52 IQR 42-64 and 52, IQR 41-64 vs.44 IQR 35-59 in those without, p=0.02)). No evidence of a significant impact of PPM on overall (p=0.71) and CV (p=0.70) mortality was observed. Patients with moderate/severe PPM had worse NYHA functional class at 1 year (NYHA III-IV 13% vs 7.8%, p=0.03). Prosthesis size≤23 mm (OR 11.6, 1.68-80.1) was an independent predictor of PPM, while SVi (OR 0.87, 0.83-0.91, p<0.001) and LVOT diameter (OR 0.79, 0.65-0.95, p=0.01) had protective effect. CONCLUSIONS: PPM was observed in 18% of patients undergoing TAVR. Echocardiographic evaluations demonstrated a PPM-related pattern of early ventricular maladaptive alterations, possibly precursor to a reduction in cardiac function, associated with a significant deterioration in NYHA class at 1 year. These findings emphasize the importance of prevention of PPM of any grade in patients undergoing TAVR procedure, especially in populations at risk.

2.
Eur J Clin Invest ; : e14209, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597271

RESUMO

BACKGROUND: In the last few years, percutaneous LAA occlusion (LAAO) has become a plausible alternative in atrial fibrillation (AF) patients with contraindications to anticoagulation therapy. Nevertheless, the optimal antiplatelet strategy following percutaneous LAAO remains to be defined. METHODS: Studies comparing single antiplatelet therapy (SAPT) versus dual antiplatelet therapy (DAPT) following LAAO were systematically searched and screened. The outcomes of interest were ischemic stroke, device-related thrombus (DRT) and major bleeding. A random-effect meta-analysis was performed comparing outcomes in both groups. The moderator effect of baseline characteristics on outcomes was evaluated by univariate meta-regression analyses. RESULTS: Sixteen observational studies with 3255 patients treated with antiplatelet therapy (SAPT, n = 1033; DAPT, n = 2222) after LAAO were included. Mean age was 74.5 ± 8.3 years, mean CHA2DS2-VASc and HAS-BLED scores were 4.3 ± 1.5 and 3.2 ± 1.0, respectively. At a weighted mean follow-up of 12.7 months, the occurrence of stroke (RR 1.33; 95% CI 0.64-2.77; p =.44), DRT (RR 1.52; 95% CI 0.90-2.58; p =.12), and the composite of stroke and DRT (RR 1.26; 95% CI 0.67-2.37; p =.47) did not differ significantly between SAPT and DAPT groups. The rate of major bleedings was also not different between groups (RR 1.41; 95% CI 0.64-3.12; p =.39). CONCLUSIONS: Among AF patients at high bleeding risk undergoing percutaneous LAAO, a post-procedural minimalistic antiplatelet strategy with SAPT did not significantly differ from DAPT regimens regarding the rate of stroke, DRT and major bleeding.

3.
Eur J Clin Invest ; : e14188, 2024 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-38396359

RESUMO

BACKGROUND: Metabolic dysfunction associated steatotic liver disease (MASLD) is associated with an increased risk of coronary artery disease. Computed Tomography Coronary Angiography (CTCA) can assess both the extent and the features of coronary plaques. We aimed to gather evidence about the prevalence and features of coronary plaques among MASLD patients. METHODS: PubMed, Scopus, and Google Scholar databases were searched for randomized controlled trials and adjusted observational studies assessing the prevalence and features of coronary plaques by means of CTCA in MASLD patients as compared with a control group. The prevalence of coronary stenosis (defined as >30% and >50% diameter of stenosis), of increasing coronary artery calcium (CAC) score and of high-risk features (namely low-attenuation plaques, napkin ring sign, spotty calcification and positive remodelling) in MASLD patients were the endpoints of interest. RESULTS: Twenty-four observational studies were included. MASLD was associated with an increased prevalence of critical coronary stenosis compared with controls (odds ratio [OR] 1.54, 95%CI 1.23-1.93). Increased values of CAC score were observed in MASLD patients (OR 1.35, 95%CI 1.02-1.78 and OR 2.26, 95%CI 1.57-3.23 for CAC score 0-100 and >100, respectively). An increased risk of 'high-risk' coronary plaques was observed in MASLD patients (OR 2.13, 95%CI 1.42-3.19). As high-risk features plaques, a higher prevalence of positive remodelling and spotty calcification characterize MASLD patients (OR 2.92, 95%CI 1.79-4.77 and OR 2.96, 95%CI 1.22-7.20). CONCLUSIONS: Patients with MASLD are at increased risk of developing critical coronary stenosis and coronary plaques characterized by high-risk features as detected by CTCA.

4.
Catheter Cardiovasc Interv ; 103(6): 843-855, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38639169

RESUMO

INTRODUCTION: Among different coronary stents implanted in High Bleeding Risk (HBR) patients with an indication for short antiplatelet therapy, no comparisons in terms of efficacy have been provided. METHODS: A Network Meta Analysis was performed including all randomized controlled trials comparing different coronary stents evaluated in HBR patients. Major Adverse Cardiovascular Events (MACEs) as defined by each included trial were the primary end point, whereas TLR (target lesion revascularization), TVR (target vessel revascularization), stent thrombosis and total and major (BARC3-5) bleedings were the secondary ones. RESULTS: A total of four studies (ONYX ONE, LEADERS FREE, SENIOR and HBR in BIO-RESORT) including 6637 patients were analyzed with different kind of stents and dual antiplatelet therapy (DAPT) length (1 or 6 months) on 12 months follow-up. About one-third of these patients were defined HBR due to indication for oral anticoagulation. All drug eluting stents (DESs) reduced risk of MACE compared to Bare Metal Stents (BMSs) when followed by a 1-month DAPT. At SUCRA analysis, Orsiro was the device with the highest probability of performing best. Rates of TLR and TVR were significantly lower when using Resolute Onyx, Synergy and BioFreedom stents in comparison to BMS when followed by 1-month DAPT, with Synergy ranking best. Synergy also showed a significantly lower number of stent thrombosis compared to BMS (RR 0.28, 95% CI 0.06-0.93), while Orsiro and Resolute Integrity showed the highest probability of performing best. CONCLUSION: In HBRs patients, all DESs were superior to BMSs in terms of efficacy and safety. Among DESs, Orsiro was the one with the highest ranking in terms of MACE, mainly driven by a reduced incidence of repeated revascularization and stent thrombosis.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Hemorragia , Metanálise em Rede , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária , Humanos , Doença da Artéria Coronariana/terapia , Trombose Coronária/etiologia , Trombose Coronária/prevenção & controle , Terapia Antiplaquetária Dupla , Hemorragia/prevenção & controle , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/administração & dosagem , Desenho de Prótese , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Eur Radiol ; 2024 Jun 06.
Artigo em Inglês | MEDLINE | ID: mdl-38844620

RESUMO

OBJECTIVES: To perform a systematic review and meta-analysis of studies investigating the diagnostic value of cardiac magnetic resonance (CMR) features for arrhythmic risk stratification in mitral valve prolapse (MVP) patients. MATERIALS AND METHODS: EMBASE, PubMed/MEDLINE, and CENTRAL were searched for studies reporting MVP patients who underwent CMR with assessment of: left ventricular (LV) size and function, mitral regurgitation (MR), prolapse distance, mitral annular disjunction (MAD), curling, late gadolinium enhancement (LGE), and T1 mapping, and reported the association with arrhythmia. The primary endpoint was complex ventricular arrhythmias (co-VAs) as defined by any non-sustained ventricular tachycardia, sustained ventricular tachycardia, ventricular fibrillation, or aborted sudden cardiac death. Meta-analysis was performed when at least three studies investigated a CMR feature. PROSPERO registration number: CRD42023374185. RESULTS: The meta-analysis included 11 studies with 1278 patients. MR severity, leaflet length/thickness, curling, MAD distance, and mapping techniques were not meta-analyzed as reported in < 3 studies. LV end-diastolic volume index, LV ejection fraction, and prolapse distance showed small non-significant effect sizes. LGE showed a strong and significant association with co-VA with a LogORs of 2.12 (95% confidence interval (CI): [1.00, 3.23]), for MAD the log odds-ratio was 0.95 (95% CI: [0.30, 1.60]). The predictive accuracy of LGE was substantial, with a hierarchical summary ROC AUC of 0.83 (95% CI: [0.69, 0.91]) and sensitivity and specificity rates of 0.70 (95% CI: [0.41, 0.89]) and 0.80 (95% CI: [0.67, 0.89]), respectively. CONCLUSIONS: Our study highlights the role of LGE as the key CMR feature for arrhythmia risk stratification in MVP patients. MAD might complement arrhythmic risk stratification. CLINICAL RELEVANCE STATEMENT: LGE is a key factor for arrhythmogenic risk in MVP patients, with additional contribution from MAD. Combining MRI findings with clinical characteristics is critical for evaluating and accurately stratifying arrhythmogenic risk in MVP patients. KEY POINTS: MVP affects 2-3% of the population, with some facing increased risk for arrhythmia. LGE can assess arrhythmia risk, and MAD may further stratify patients. CMR is critical for MVP arrhythmia risk stratification, making it essential in a comprehensive evaluation.

6.
Cardiovasc Diabetol ; 22(1): 80, 2023 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-37005586

RESUMO

BACKGROUND: Sodium-glucose transporter 2 inhibitors (SGLT2-I) could modulate atherosclerotic plaque progression, via down-regulation of inflammatory burden, and lead to reduction of major adverse cardiovascular events (MACEs) in type 2 diabetes mellitus (T2DM) patients with ischemic heart disease (IHD). T2DM patients with multivessel non-obstructive coronary stenosis (Mv-NOCS) have over-inflammation and over-lipids' plaque accumulation. This could reduce fibrous cap thickness (FCT), favoring plaque rupture and MACEs. Despite this, there is not conclusive data about the effects of SGLT2-I on atherosclerotic plaque phenotype and MACEs in Mv-NOCS patients with T2DM. Thus, in the current study, we evaluated SGLT2-I effects on Mv-NOCS patients with T2DM in terms of FCT increase, reduction of systemic and coronary plaque inflammation, and MACEs at 1 year of follow-up. METHODS: In a multi-center study, we evaluated 369 T2DM patients with Mv-NOCS divided in 258 (69.9%) patients that did not receive the SGLT2-I therapy (Non-SGLT2-I users), and 111 (30.1%) patients that were treated with SGLT2-I therapy (SGLT2-I users) after percutaneous coronary intervention (PCI) and optical coherence tomography (OCT) evaluation. As the primary study endpoint, we evaluated the effects of SGLT2-I on FCT changes at 1 year of follow-up. As secondary endpoints, we evaluated at baseline and at 12 months follow-up the inflammatory systemic and plaque burden and rate of MACEs, and predictors of MACE through multivariable analysis. RESULTS: At 6 and 12 months of follow-up, SGLT2-I users vs. Non-SGLT2-I users showed lower body mass index (BMI), glycemia, glycated hemoglobin, B-type natriuretic peptide, and inflammatory cells/molecules values (p < 0.05). SGLT2-I users vs. Non-SGLT2-I users, as evaluated by OCT, evidenced the highest values of minimum FCT, and lowest values of lipid arc degree and macrophage grade (p < 0.05). At the follow-up end, SGLT2-I users vs. Non-SGLT2-I users had a lower rate of MACEs [n 12 (10.8%) vs. n 57 (22.1%); p < 0.05]. Finally, Hb1Ac values (1.930, [CI 95%: 1.149-2.176]), macrophage grade (1.188, [CI 95%: 1.073-1.315]), and SGLT2-I therapy (0.342, [CI 95%: 0.180-0.651]) were independent predictors of MACEs at 1 year of follow-up. CONCLUSIONS: SGLT2-I therapy may reduce about 65% the risk to have MACEs at 1 year of follow-up, via ameliorative effects on glucose homeostasis, and by the reduction of systemic inflammatory burden, and local effects on the atherosclerotic plaque inflammation, lipids' deposit, and FCT in Mv-NOCS patients with T2DM.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Diabetes Mellitus Tipo 2 , Isquemia Miocárdica , Intervenção Coronária Percutânea , Placa Aterosclerótica , Inibidores do Transportador 2 de Sódio-Glicose , Humanos , Doença da Artéria Coronariana/terapia , Placa Aterosclerótica/patologia , Inibidores do Transportador 2 de Sódio-Glicose/efeitos adversos , Diabetes Mellitus Tipo 2/complicações , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Intervenção Coronária Percutânea/métodos , Estenose Coronária/diagnóstico por imagem , Estenose Coronária/tratamento farmacológico , Estenose Coronária/patologia , Isquemia Miocárdica/diagnóstico por imagem , Isquemia Miocárdica/tratamento farmacológico , Fibrose , Vasos Coronários/diagnóstico por imagem , Vasos Coronários/patologia , Lipídeos , Inflamação/patologia , Tomografia de Coerência Óptica/métodos
7.
Cardiovasc Diabetol ; 22(1): 324, 2023 11 28.
Artigo em Inglês | MEDLINE | ID: mdl-38017541

RESUMO

BACKGROUND AND AIMS: Bempedoic Acid (BA) is a novel Lipid-Lowering Therapy (LLT). We performed a systematic review and meta-analysis to assess the efficacy and safety of BA in patients with hypercholesterolemia. METHODS: PubMed, Scopus, and Cochrane library databases were searched for randomised controlled trials evaluating the efficacy and/or safety of BA compared with placebo. Trials investigating dosages other than 180 mg/die were excluded. Major adverse cardiovascular events (MACE) were the primary efficacy endpoint. LDL-cholesterol reduction was the primary laboratory endpoint. Pre-specified safety endpoints included muscle-related adverse events, new-onset diabetes, and gout. The protocol was registered on PROSPERO (temporary ID:399,867). RESULTS: Study search identified 275 deduplicated results. 11 studies, encompassing 18,315 patients (9854 on BA vs 8461 on placebo/no treatment) were included. BA was associated with a reduced risk of MACE (OR 0.86, 95% CI 0.79-0.95), myocardial infarction (OR 0.76, 95% CI 0.64-0.88) and unstable angina (OR 0.69, 95% CI 0.54-0.88) compared to control, over a median follow up of 87 (15-162) weeks. BA was associated with a reduction of LDL-Cholesterol (mean difference [MD]-22.42,95% CI - 24.02% to - 20.82%), total cholesterol (- 16.50%,95% - 19.21% to - 13.79%), Apo-B lipoprotein (- 19.55%, - 22.68% to - 16.42%) and high-sensitivity CRP (- 27.83%, - 31.71% to - 23.96%) at 12 weeks. BA was associated with a higher risk of gout (OR 1.55, 95% CI 1.27-1.90) as compared with placebo. Efficacy on laboratory endpoints was confirmed, with a variable extent, across patients on statin or ezetimibe background therapy. CONCLUSIONS: The improved cholesterol control achieved with BA translates into a reduced risk of MACE, including myocardial infarction and coronary revascularisation. The drug has a satisfactory safety profile except for an increased risk of gout.


Assuntos
Gota , Inibidores de Hidroximetilglutaril-CoA Redutases , Infarto do Miocárdio , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , LDL-Colesterol , Colesterol , Infarto do Miocárdio/diagnóstico , Infarto do Miocárdio/tratamento farmacológico , Gota/induzido quimicamente , Gota/tratamento farmacológico , Resultado do Tratamento , Ensaios Clínicos Controlados Aleatórios como Assunto
8.
Catheter Cardiovasc Interv ; 102(4): 620-630, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37668085

RESUMO

BACKGROUND: It is still unclear the impact of diabetes mellitus (DM) in complex coronary lesions treated with percutaneous coronary intervention (PCI) which themselves are at increased incidence of adverse events. METHODS: BIFURCAT registry encompassed patients treated with PCI for coronary bifurcation lesion from the COBIS III and the RAIN registry. The primary endpoint was the occurrence of major cardiovascular adverse event (MACE), a composite and mutual exclusive of all-cause death or myocardial infarction (MI) or target-lesion revascularization (TLR). A total of 5537 patients were included in the analysis and 1834 (33%) suffered from DM. RESULTS: After a median follow-up of 21 months, diabetic patients had a higher incidence of MACE (17% vs. 9%, p < 0.001), all-cause mortality (9% vs. 4%, p < 0.001), TLR (5% vs. 3%, p = 0.001), MI (4% vs. 2%, p < 0.001), and stent thrombosis (ST) (2% vs. 1%, p = 0.007). After multivariate analysis, diabetes remained significantly associated with MACE (hazard ratio [HR]: 1.37; confidence interval [CI]: 1.13-1.65; p = 0.001), all-cause death (HR: 1.65; 95% CI: 1.24-2.19, p = 0.001), TLR (HR: 1.45; CI: 1.03-2.04; p = 0.031) and ST (HR: 1.73, CI: 1.04-2.88; p = 0.036), but not with MI (HR: 1.34; CI: 0.93-1.92; p = 0.11). Among diabetics, chronic kidney disease (HR: 2.99; CI: 2.21-4.04), baseline left ventricular ejection fraction (HR: 0.98; CI: 0.97-0.99), femoral access (HR: 1.62; CI: 1.23-2.15), left main coronary artery (HR: 1.44; CI: 1.06-1.94), main branch diameter (HR: 0.79; CI: 0.66-0.94) and final kissing balloon (HR: 0.70; CI: 0.52-0.93) were independent predictors of MACE at follow-up. CONCLUSIONS: Patients with DM treated with PCI for coronary bifurcations have a worse prognosis due to higher incidence of MACE, all-cause mortality, TLR and ST compared to the non-diabetics.


Assuntos
Doença da Artéria Coronariana , Diabetes Mellitus , Stents Farmacológicos , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações , Intervenção Coronária Percutânea/efeitos adversos , Volume Sistólico , Resultado do Tratamento , Fatores de Risco , Stents Farmacológicos/efeitos adversos , Função Ventricular Esquerda , Infarto do Miocárdio/etiologia , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Sistema de Registros , Estudos Retrospectivos
9.
Catheter Cardiovasc Interv ; 102(2): 221-232, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37232278

RESUMO

BACKGROUND: Data about the long-term performance of new-generation ultrathin-strut drug-eluting stents (DES) in challenging coronary lesions, such as left main (LM), bifurcation, and chronic total occlusion (CTO) lesions are scant. METHODS: The international multicenter retrospective observational ULTRA study included consecutive patients treated from September 2016 to August 2021 with ultrathin-strut (<70 µm) DES in challenging de novo lesions. Primary endpoint was target lesion failure (TLF): composite of cardiac death, target-lesion revascularization (TLR), target-vessel myocardial infarction (TVMI), or definite stent thrombosis (ST). Secondary endpoints included all-cause death, acute myocardial infarction (AMI), target vessel revascularization, and TLF components. TLF predictors were assessed with Cox multivariable analysis. RESULTS: Of 1801 patients (age: 66.6 ± 11.2 years; male: 1410 [78.3%]), 170 (9.4%) experienced TLF during follow-up of 3.1 ± 1.4 years. In patients with LM, CTO, and bifurcation lesions, TLF rates were 13.5%, 9.9%, and 8.9%, respectively. Overall, 160 (8.9%) patients died (74 [4.1%] from cardiac causes). AMI and TVMI rates were 6.0% and 3.2%, respectively. ST occurred in 11 (1.1%) patients while 77 (4.3%) underwent TLR. Multivariable analysis identified the following predictors of TLF: age, STEMI with cardiogenic shock, impaired left ventricular ejection fraction, diabetes, and renal dysfunction. Among the procedural variables, total stent length increased TLF risk (HR: 1.01, 95% CI: 1-1.02 per mm increase), while intracoronary imaging reduced the risk substantially (HR: 0.35, 95% CI: 0.12-0.82). CONCLUSIONS: Ultrathin-strut DES showed high efficacy and satisfactory safety, even in patients with challenging coronary lesions. Yet, despite using contemporary gold-standard DES, the association persisted between established patient- and procedure-related features of risk and impaired 3-year clinical outcome.


Assuntos
Doença da Artéria Coronariana , Infarto do Miocárdio , Intervenção Coronária Percutânea , Humanos , Masculino , Pessoa de Meia-Idade , Idoso , Sirolimo , Estudos Retrospectivos , Volume Sistólico , Resultado do Tratamento , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Função Ventricular Esquerda , Infarto do Miocárdio/etiologia , Desenho de Prótese , Stents/efeitos adversos , Sistema de Registros , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Doença da Artéria Coronariana/complicações
10.
Lancet ; 397(10270): 199-207, 2021 01 16.
Artigo em Inglês | MEDLINE | ID: mdl-33453782

RESUMO

BACKGROUND: The accuracy of current prediction tools for ischaemic and bleeding events after an acute coronary syndrome (ACS) remains insufficient for individualised patient management strategies. We developed a machine learning-based risk stratification model to predict all-cause death, recurrent acute myocardial infarction, and major bleeding after ACS. METHODS: Different machine learning models for the prediction of 1-year post-discharge all-cause death, myocardial infarction, and major bleeding (defined as Bleeding Academic Research Consortium type 3 or 5) were trained on a cohort of 19 826 adult patients with ACS (split into a training cohort [80%] and internal validation cohort [20%]) from the BleeMACS and RENAMI registries, which included patients across several continents. 25 clinical features routinely assessed at discharge were used to inform the models. The best-performing model for each study outcome (the PRAISE score) was tested in an external validation cohort of 3444 patients with ACS pooled from a randomised controlled trial and three prospective registries. Model performance was assessed according to a range of learning metrics including area under the receiver operating characteristic curve (AUC). FINDINGS: The PRAISE score showed an AUC of 0·82 (95% CI 0·78-0·85) in the internal validation cohort and 0·92 (0·90-0·93) in the external validation cohort for 1-year all-cause death; an AUC of 0·74 (0·70-0·78) in the internal validation cohort and 0·81 (0·76-0·85) in the external validation cohort for 1-year myocardial infarction; and an AUC of 0·70 (0·66-0·75) in the internal validation cohort and 0·86 (0·82-0·89) in the external validation cohort for 1-year major bleeding. INTERPRETATION: A machine learning-based approach for the identification of predictors of events after an ACS is feasible and effective. The PRAISE score showed accurate discriminative capabilities for the prediction of all-cause death, myocardial infarction, and major bleeding, and might be useful to guide clinical decision making. FUNDING: None.


Assuntos
Síndrome Coronariana Aguda/complicações , Conjuntos de Dados como Assunto , Aprendizado de Máquina , Mortalidade , Complicações Pós-Operatórias , Adulto , Tomada de Decisão Clínica , Feminino , Hemorragia/etiologia , Humanos , Masculino
11.
Catheter Cardiovasc Interv ; 100(1): 122-130, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35485723

RESUMO

INTRODUCTION: Despite limited to short and midterm outcomes, valve-in-valve (ViV) transcatheter aortic valve implantation (TAVI) has emerged as a valid alternative to re-surgical aortic valve replacement (re-SAVR) for high- and intermediate-risk patients with degenerated surgical bioprosthesis. METHODS: All studies comparing multivariate adjustment between ViV TAVI and re-SAVR were screened. The primary end-points were all-cause and cardiovascular (CV) mortality at 30 days and at Midterm follow-up. Short-term complications were the secondary endpoints. RESULTS: We obtained data from 11 studies, encompassing 8570 patients, 4224 undergoing ViV TAVI, and 4346 re-SAVR. Four studies included intermediate-risk patients and seven high-risk patients. 30-day all-cause and CV mortality were significantly lower in ViV (odds ratio [OR] 0.43, 95% confidence intervals [CIs] 0.29-0.64 and OR 0.44, 0.26-0.73 respectively), while after a mean follow-up of 717 (180-1825) days, there was no difference between the two groups (OR 1.04, 0.87-1.25 and OR 1.05, 0.78-1.43, respectively). The risk of stroke (OR 1.03, 0.59-1.82), MI (OR 0.70, 0.34-1.44), major vascular complications (OR 0.92, 0.50-1.67), and permanent pacemaker implantation (OR 0.67, 0.36-1.25) at 30 days did not differ, while major bleedings and new-onset atrial fibrillation were significantly lower in ViV patients (OR 0.41, 0.25-0.67 and OR 0.23, 0.12-0.42, respectively, all 95% CIs). CONCLUSIONS: In high- and intermediate-risk patients with degenerated surgical bioprostheses, ViV TAVI is associated with reduced short-term mortality, compared with re-SAVR. Nevertheless, no differences were found in all-cause and CV mortality at midterm follow-up. PROSPERO CRD42021226488.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
12.
Eur Radiol ; 32(8): 5189-5200, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35192010

RESUMO

OBJECTIVE: To evaluate the diagnostic accuracy of coronary computed tomography angiography (CCTA) for the evaluation of obstructive coronary artery disease (CAD) in patients referred for transcatheter aortic valve implantation (TAVI). METHODS: EMBASE, PubMed/MEDLINE, and CENTRAL were searched for studies reporting accuracy of CCTA for the evaluation of obstructive CAD compared with invasive coronary angiography (ICA) as the reference standard. QUADAS-2 tool was used to assess the risk of bias. A bivariate random effects model was used to analyze, pool, and plot the diagnostic performance measurements across studies. Pooled sensitivity, specificity, positive ( + LR) and negative (-LR) likelihood ratio, diagnostic odds ratio (DOR), and hierarchical summary ROC curve (HSROC) were evaluated. Prospero registration number: CRD42021252527. RESULTS: Fourteen studies (2533 patients) were included. In the intention-to-diagnose patient-level analysis, sensitivity and specificity for CCTA were 97% (95% CI: 94-98%) and 68% (95% CI: 56-68%), respectively, and + LR and -LR were 3.0 (95% CI: 2.1-4.3) and 0.05 (95% CI: 0.03 - 0.09), with DOR equal to 60 (95% CI: 30-121). The area under the HSROC curve was 0.96 (95% CI: 0.94-0.98). No significant difference in sensitivity was found between single-heartbeat and other CT scanners (96% (95% CI: 90 - 99%) vs. 97% (95% CI: 94-98%) respectively; p = 0.37), whereas the specificity of single-heartbeat scanners was higher (82% (95% CI: 66-92%) vs. 60% (95% CI: 46 - 72%) respectively; p < 0.0001). Routine CCTA in the pre-TAVI workup could save 41% (95% CI: 34 - 47%) of ICAs if a disease prevalence of 40% is assumed. CONCLUSIONS: CCTA proved an excellent diagnostic accuracy for assessing obstructive CAD in patients referred for TAVI; the use of single-heartbeat CT scanners can further improve these findings. KEY POINTS: • CCTA proved to have an excellent diagnostic accuracy for assessing obstructive CAD in patients referred for TAVI. • Routine CCTA in the pre-TAVI workup could save more than 40% of ICAs. • Single-heartbeat CT scanners had higher specificity than others in the assessment of obstructive CAD in patients referred for TAVI.


Assuntos
Doença da Artéria Coronariana , Estenose Coronária , Substituição da Valva Aórtica Transcateter , Angiografia por Tomografia Computadorizada/métodos , Angiografia Coronária/métodos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Humanos , Tomografia Computadorizada por Raios X/métodos , Substituição da Valva Aórtica Transcateter/métodos
13.
Catheter Cardiovasc Interv ; 98(1): E18-E23, 2021 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-33315297

RESUMO

BACKGROUND: Clinical benefits of FFR (Fraction Flow Reserve) driven CABG (Coronary Artery Bypass Graft) remain to be established. METHODS: All randomized controlled trials (RCTs) and observational studies with multivariable adjustement were included. MACE (Major Adverse Cardiac Events) was the primary end point, while its single components (death, myocardial infarction, and total vessel revascularization [TVR]) along with number of anastomoses, on pump procedures and graft occlusion at angiographic follow-up were the secondary ones. Each analysis was stratified for RCTs versus observational studies. RESULTS: Four studies (two RCTs and two observational) were included, enrolling 983 patients, 542 angio-guided and 441 FFR-guided. Mean age was 68.45 years, 79% male, with a mean EuroSCORE I of 2.7. Coronary lesions were located in 37% of patients in the left anterior descending artery, 32% in the circumflex artery, and 26% in the right coronary artery. After a mean follow-up of 40 months, risk of MACE did not differ (OR 0.86 [0.63-1.18]) as that of all cause death (OR 0.86 [0.59-1.25]), MI (OR 0.57 [0.30-1.11]) and TVR (OR 1.10 [0.65-1.85]). FFR-driven CABG reduced on-pump procedures (OR 0.58 [0.35-0.93]) and number of anastomoses (-0.40 [-0.80: -0.01]) while incidence of graft occlusion at follow-up did not differ (OR 0.59 [0.30-1.15], all CI 95%). CONCLUSION: Fraction flow reserve driven CABG reduced the number of anastomoses and of on-pump procedures without increasing risk of MACE and without reducing graft occlusion at angiographic follow-up. ID CRD42020211945.


Assuntos
Doença da Artéria Coronariana , Reserva Fracionada de Fluxo Miocárdico , Intervenção Coronária Percutânea , Idoso , Angiografia Coronária , Ponte de Artéria Coronária/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/cirurgia , Feminino , Seguimentos , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 97(4): 581-588, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-32790145

RESUMO

BACKGROUND: The optimal antithrombotic regimen in patients with a concomitant indication for oral anticoagulation (OAT) presenting with acute coronary syndrome (ACS) or undergoing percutaneous coronary intervention (PCI) remains unclear. OBJECTIVES: To perform a network meta-analysis of all randomized controlled trials (RCTs) evaluating different antithrombotic regimens among patients with ACS or undergoing PCI requiring OAT. METHODS: Network meta-analysis was performed in a frequentist framework. Antithrombotic regimens were categorized by OAC type (vitamin K antagonist-based [VKA]; non-VKA OAT [NOAC]) and antiplatelet agents (P2Y inhibitor only: dual therapy [DAT]; P2Y plus aspirin: triple therapy [TAT]). Safety outcomes were Thrombolysis in Myocardial Infarction (TIMI) major bleeding and intracranial hemorrhage (ICH). Efficacy outcomes were cardiovascular death, myocardial infarction, stroke and stent-thrombosis (ST). RESULTS: Five RCTs were included, encompassing 10,797 patients (atrial fibrillation 69-100%, ACS 28-62%, PCI 77-100%). Both VKA and NOAC-based DAT regimens reduced the occurrence of TIMI major bleeding compared to VKA TAT (VKA DAT: RR 0.62, 95% CI 0.39-0.98; NOAC DAT: RR 0.52, 95% CI 0.39-0.70). Nevertheless, only NOAC DAT significantly reduced the occurrence of ICH compared to VKA TAT (RR 0.33, 95% CI 0.17-0.64). Ischemic outcomes were similar among the four treatment regimens. However, numerical, potentially clinically important, higher ST occurrence was observed for NOAC DAT as compared to both VKA TAT (1.50, 95% confidence interval [CI] 0.96-2.33) and NOAC TAT (1.86, 95% CI 0.93-3.73). CONCLUSION: DAT regimens present the highest safety profile among antithrombotic strategies, with a NOAC-specific impact on ICH reduction. NOAC DAT might entail clinically important higher ST occurrence, warranting a case-by-case comprehensive evaluation that integrates patient- and procedure-related residual ischemic risk with the patient-specific bleeding risk.


Assuntos
Fibrilação Atrial , Intervenção Coronária Percutânea , Anticoagulantes/efeitos adversos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrinolíticos/efeitos adversos , Humanos , Metanálise em Rede , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do Tratamento
15.
Catheter Cardiovasc Interv ; 97(2): E227-E236, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32438488

RESUMO

BACKGROUND: The PARIS risk score (PARIS-rs) and percutaneous coronary intervention complexity (PCI-c) predict clinical and procedural residual ischemic risk following PCI. Their accuracy in patients undergoing unprotected left main (ULM) or bifurcation PCI has not been assessed. METHODS: The predictive performances of the PARIS-rs (categorized as low, intermediate, and high) and PCI-c (according to guideline-endorsed criteria) were evaluated in 3,002 patients undergoing ULM/bifurcation PCI with very thin strut stents. RESULTS: After 16 (12-22) months, increasing PARIS-rs (8.8% vs. 14.1% vs. 27.4%, p < .001) and PCI-c (15.2% vs. 11%, p = .025) were associated with higher rates of major adverse cardiac events ([MACE], a composite of death, myocardial infarction [MI], and target vessel revascularization), driven by MI/death for PARIS-rs and target lesion revascularization/stent thrombosis for PCI-c (area under the curves for MACE: PARIS-rs 0.60 vs. PCI-c 0.52, p-for-difference < .001). PCI-c accuracy for MACE was higher in low-clinical-risk patients; while PARIS-rs was more accurate in low-procedural-risk patients. ≥12-month dual antiplatelet therapy (DAPT) was associated with a lower MACE rate in high PARIS-rs patients, (adjusted-hazard ratio 0.42 [95% CI: 0.22-0.83], p = .012), with no benefit in low to intermediate PARIS-rs patients. No incremental benefit with longer DAPT was observed in complex PCI. CONCLUSIONS: In the setting of ULM/bifurcation PCI, the residual ischemic risk is better predicted by a clinical risk estimator than by PCI complexity, which rather appears to reflect stent/procedure-related events. Careful procedural risk estimation is warranted in patients at low clinical risk, where PCI complexity may substantially contribute to the overall residual ischemic risk.


Assuntos
Doença da Artéria Coronariana , Stents Farmacológicos , Intervenção Coronária Percutânea , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Intervenção Coronária Percutânea/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Fatores de Risco , Stents , Resultado do Tratamento
16.
Cardiovasc Drugs Ther ; 35(5): 987-993, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-32918655

RESUMO

PURPOSE: Patients with patent foramen ovale (PFO) and cryptogenic ischemic stroke (CS) are at risk for stroke recurrence. The optimal antithrombotic strategy in patients who undergo medical management is still debated. METHODS: We systematically searched the literature for studies that reported on cerebrovascular event recurrences and/or death in patients with PFO treated with oral anticoagulation (OAC) or antiplatelet therapy (APT) for secondary prevention of CS. The efficacy endpoints were stroke recurrence and the composite of stroke, transient ischemic attack or all-cause death. Major bleedings represented the safety endpoint. RESULTS: A total of 16 studies with 3953 patients (OAC = 1527, APT = 2426) were included. Weighted mean follow-up was 2.9 years. OAC was associated with a significant reduction in the risk of stroke compared with APT (RR 0.65; 95% CI 0.44-0.95; ARR 2%, NNT 49), while no difference was found regarding the composite outcome (RR 0.78; 95% CI 0.57-1.07) and the safety outcome (RR 1.57; 95% CI 0.85-2.90; p = 0.15). CONCLUSIONS: OAC was more effective than APT in reducing the risk of stroke recurrence in patients with PFO and CS, without a significant increase in the risk of major bleedings. Our findings support the need for further randomized data focused on the comparison of antithrombotic strategies in this setting.


Assuntos
Anticoagulantes/uso terapêutico , Forame Oval Patente/tratamento farmacológico , Forame Oval Patente/epidemiologia , AVC Isquêmico/epidemiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Hemorragia/induzido quimicamente , Humanos , Inibidores da Agregação Plaquetária/administração & dosagem , Inibidores da Agregação Plaquetária/efeitos adversos , Recidiva
17.
Catheter Cardiovasc Interv ; 96(1): 1-9, 2020 07.
Artigo em Inglês | MEDLINE | ID: mdl-31860158

RESUMO

OBJECTIVES: To evaluate the independent clinical impact of stent structural features in a large cohort of patients undergoing unprotected left main (ULM) or coronary bifurcation percutaneous coronary intervention (PCI) with a range of very thin strut stents. BACKGROUND: Clinical impact of structural features of contemporary stents remains to be defined. METHODS: All consecutive patients enrolled in the veRy thin stents for patients with left mAIn or bifurcatioN in real life (RAIN) registry were included. The following stent structural features were studied: antiproliferative drugs (everolimus vs. sirolimus vs. zotarolimus), strut material (platinum-chromium vs. cobalt-chromium), polymer (bioresorbable vs. durable), number of crowns (<8 vs. ≥8) and number of connectors (<3 vs. ≥3). For small diameter stents (≤2.5 mm), struct thickness (74 vs. 80/81 µm) was also tested. Target lesion failure (TLF), a composite of target lesion revascularization and stent thrombosis, was the primary endpoint. Multivariate analysis was performed with Cox regression models. RESULTS: Out of 2,707 patients, 110 (4.1%) experienced a TLF event after 16 months (12-18). After adjustment for confounders, an increased number of connectors (adjusted hazard ratio [adj-HR] 0.62, 95% confidence interval (CI) 0.39-0.99, p = .04) reduced risk of TLF, driven by stents with ≥2.5 mm diameter (HR 0.54, 95% CI 0.32-0.93, p = .02). This independent relationship was lost for stents with diameter <2.5 mm, where only strut thickness appeared to impact. Conversely, no independent relationship of polymer type, number of crowns, and the specific limus-family eluted drug with outcomes was observed. CONCLUSIONS: Among a range of contemporary very thin stent models, an increased number of connectors improved device-related outcomes in this investigated high-risk procedural setting.


Assuntos
Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Idoso , Doença da Artéria Coronariana/diagnóstico por imagem , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
BMC Cardiovasc Disord ; 20(1): 29, 2020 01 23.
Artigo em Inglês | MEDLINE | ID: mdl-31973746

RESUMO

BACKGROUND: Evidence-based recommendations about anticoagulation in acute type B aortic dissection (TBAD) are completely missing, but there is a diffuse conviction that it could prevent the healing process of the dissected aorta's false lumen. However, several clinical conditions may lead to the necessity to start anticoagulant therapy among patients with acute type B aortic dissection, ranging from atrial fibrillation to more complicated clinical scenarios and the correct management in this kind of patients is still an open issue. CASE PRESENTATION: We are presenting a 51-years-old man with multi-infarct encephalopathy referred to us for an acute TBAD and a first diagnosis of ischemic cardiomyopathy complicated by left ventricular (LV) thrombus formation. Coronary angiography revealed a critical stenosis of left anterior descending artery (LAD) treated with drug-eluting stent deployment. The patient was addressed to triple antithrombotic therapy with acetylsalicylic acid, clopidogrel and warfarin with target INR 2.0-2.5. After 6 months, computed tomography angiography revealed the stability of the dissection flap. Cardiac magnetic resonance imaging, however, confirmed the persistence of a small thrombotic formation in LV apex, thus double antithrombotic therapy with warfarin and clopidogrel was instituted. The patient remained asymptomatic during the follow-up period but was advised to suspend his job and physical activities. CONCLUSION: Current guidelines do not discuss anticoagulant therapy in the setting of TBAD and large randomized trials are lacking. Despite it is generally considered unsafe to administer anticoagulants in patients with TBAD, we present a case in which triple antithrombotic therapy was well tolerated and did not lead to progression of the intimal flap after 6 months.


Assuntos
Anticoagulantes/administração & dosagem , Aneurisma da Aorta Torácica/complicações , Dissecção Aórtica/complicações , Aspirina/administração & dosagem , Clopidogrel/administração & dosagem , Estenose Coronária/terapia , Fibrinolíticos/administração & dosagem , Intervenção Coronária Percutânea , Inibidores da Agregação Plaquetária/administração & dosagem , Trombose/tratamento farmacológico , Varfarina/administração & dosagem , Dissecção Aórtica/diagnóstico por imagem , Anticoagulantes/efeitos adversos , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aspirina/efeitos adversos , Tomada de Decisão Clínica , Clopidogrel/efeitos adversos , Estenose Coronária/complicações , Estenose Coronária/diagnóstico por imagem , Progressão da Doença , Stents Farmacológicos , Terapia Antiplaquetária Dupla , Fibrinolíticos/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Inibidores da Agregação Plaquetária/efeitos adversos , Medição de Risco , Trombose/complicações , Trombose/diagnóstico por imagem , Resultado do Tratamento , Varfarina/efeitos adversos
20.
N Engl J Med ; 383(1): 88-89, 2020 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-32343497
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA