1.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Artigo em Inglês | MEDLINE | ID: mdl-37212442

RESUMO

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Assuntos
Arritmias Cardíacas , Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Fibrilação Atrial/terapia , Fibrilação Atrial/etiologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial/efeitos adversos , Estimulação Cardíaca Artificial/métodos , Seguimentos , Marca-Passo Artificial/efeitos adversos , Estudos Prospectivos , Resultado do Tratamento , Arritmias Cardíacas/terapia
2.
Circulation ; 2024 Jul 08.
Artigo em Inglês | MEDLINE | ID: mdl-38973458

RESUMO

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for AV synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The AV synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of AV synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between AV synchrony and i2i success, posture/activity, implantation indication, AV event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean AV synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrium-to-ventricle i2i (94%) and ventricle-to-atrium i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. AV synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, AV paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated AV synchrony in 98% of evaluable beats at 3 months after implantation. AV synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.

3.
J Cardiovasc Electrophysiol ; 34(4): 833-840, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786515

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) is well established as a primary treatment for atrial fibrillation (AF). The POLAR ICE study was designed to collect prospective real world data on the safety and effectiveness of the POLARxTM cryoballoon for PVI to treat paroxysmal AF. METHODS: POLAR ICE, a prospective, non-randomized, multicenter (international) registry (NCT04250714), enrolled 399 patients across 19 European centers. Procedural characteristics, such as time to isolation, cryoablations per pulmonary vein (PV), balloon nadir temperature, and occlusion grade were recorded. PVI was confirmed with entrance block testing. RESULTS: Data on 372 de novo PVI procedures (n = 2190 ablations) were collected. Complete PVI was achieved in 96.8% of PVs. Procedure and fluoroscopy times were 68.2 ± 24.6 and 15.6 ± 9.6 min, respectively. Left atrial dwell time was 46.6 ± 18.3 min. Grade 3 or 4 occlusion was achieved in 98.2% of PVs reported and 71.2% of PVs isolation required only a single cryoablation. Of 2190 cryoapplications, 83% had a duration of at least 120 s; nadir temperature of these ablations averaged -56.3 ± 6.5°C. There were 6 phrenic nerve palsy events, 2 of which resolved within 3 months of the procedure. CONCLUSION: This real-world usage data on a novel cryoballoon suggests this device is effective, safe, and relatively fast in centers with cryoballoon experience. These data are comparable to prior POLARx reports and in keeping with reported data on other cryoballoons. Future studies should examine the long-term outcomes and the relationship between biophysical parameters and outcomes for this novel cryoballoon.


Assuntos
Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Átrios do Coração , Fluoroscopia
4.
Europace ; 25(8)2023 08 25.
Artigo em Inglês | MEDLINE | ID: mdl-37421338

RESUMO

AIMS: Cardiac pacing represents a key element in the field of electrophysiology and the treatment of conduction diseases. Since the first issue published in 1999, EP Europace has significantly contributed to the development and dissemination of the research in this area. METHODS: In the last 25 years, there has been a continuous improvement of technologies and a great expansion of clinical indications making the field of cardiac pacing a fertile ground for research still today. Pacemaker technology has rapidly evolved, from the first external devices with limited longevity, passing through conventional transvenous pacemakers to leadless devices. Constant innovations in pacemaker size, longevity, pacing mode, algorithms, and remote monitoring highlight that the fascinating and exciting journey of cardiac pacing is not over yet. CONCLUSION: The aim of the present review is to provide the current 'state of the art' on cardiac pacing highlighting the most important contributions from the Journal in the field.


Assuntos
Estimulação Cardíaca Artificial , Marca-Passo Artificial , Humanos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Desenho de Equipamento , Doença do Sistema de Condução Cardíaco/terapia
5.
Europace ; 26(1)2023 12 28.
Artigo em Inglês | MEDLINE | ID: mdl-38175788

RESUMO

AIMS: Pulsed field ablation (PFA) has been proposed as a novel alternative to radiofrequency (RF) and cryoablation in the treatment of atrial fibrillation (AF). Following the occurrence of two cases of acute kidney injury (AKI) secondary to haemolysis after a PFA procedure, we evaluated haemolysis in a cohort of consecutive patients. METHODS AND RESULTS: Two cases of AKI occurred in last May and June 2023. AKI was secondary to acute and severe haemolysis after a PFA procedure. From June 2023, a total of 68 consecutive patients (64.3 ± 10.5 years) undergoing AF ablation with PFA were enrolled in the study. All patients had a blood sample the day after the procedure for the assessment of haemolysis indicators. The pentaspline PFA catheter was used with a total number of median applications of 64 (54; 76). Nineteen patients (28%) showed significantly depleted haptoglobin levels (<0.04 g/L). A significant inverse correlation was found between the plasma level of haptoglobin and the total number of applications. Two groups were compared: the haemolysis+ group (haptoglobin < 0.04 g/L) vs. the haemolysis- group. The total number of applications was significantly higher in the haemolysis+ group vs the haemolysis - group respectively 75 (62; 127) vs 62 (54; 71) P = 0.011. More than 70 applications seem to have better sensitivity and specificity to predict haemolysis. CONCLUSION: Intravascular haemolysis can occur after certain procedures of PFA. Acute kidney injury is a phenomenon that appears to be very rare after a PFA procedure. However, caution must be exercised in the number of applications to avoid severe haemolysis.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Hemólise , Haptoglobinas , Injúria Renal Aguda/diagnóstico , Injúria Renal Aguda/etiologia , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
6.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37757839

RESUMO

AIMS: While numerous studies have demonstrated favourable safety and efficacy of the excimer laser sheath for transvenous lead extraction (TLE) in smaller cohorts, comprehensive large-scale investigations with contemporary data remain scarce. This study aims to evaluate the safety and performance of laser-assisted TLE through a meta-analysis of contemporary data. METHODS AND RESULTS: A systematic literature search was conducted to identify articles that assessed the safety and performance of the spectranetics laser sheath (SLS) II and GlideLight Excimer laser sheaths in TLE procedures between 1 April 2016 and 31 March 2021. Safety outcomes included procedure-related death and major/minor complications. Performance outcomes included procedural and clinical success rates. A random-effects, inverse-variance-weighting meta-analysis was performed to obtain the weighted average of the evaluated outcomes. In total, 17 articles were identified and evaluated, including 1729 patients with 2887 leads. Each patient, on average, had 2.3 ± 0.3 leads with a dwell time of 7.9 ± 3.0 years. The TLE procedural successes rate was 96.8% [1440/1505; 95% CI: (94.9-98.2%)] per patient and 96.3% [1447/1501; 95% CI: (94.8-97.4%)] per lead, and the clinical success rate per patient was 98.3% [989/1010, 95% CI: (97.4-99.0%)]. The procedure-related death rate was 0.08% [7/1729, 95% CI: (0.00%, 0.34%)], with major and minor complication rates of 1.9% [41/1729; 95% CI: (1.2-2.8%)] and 1.9% [58/1729; 95% CI: (0.8-3.6%)], respectively. CONCLUSION: This meta-analysis demonstrated that excimer laser sheath-assisted TLE has high success and low procedural mortality rates. It provides clinicians with a reliable and valuable resource for extracting indwelling cardiac leads which require advanced extraction techniques.


Assuntos
Remoção de Dispositivo , Humanos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Lasers de Excimer/efeitos adversos , Marca-Passo Artificial , Estudos Retrospectivos , Resultado do Tratamento
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37021342

RESUMO

AIMS: While elevated resting heart rate measured at a single point of time has been associated with cardiovascular outcomes, utility of continuous monitoring of nocturnal heart rate (NHR) has never been evaluated. We hypothesized that dynamic NHR changes may predict, at short term, impending cardiovascular events in patients equipped with a wearable cardioverter-defibrillator (WCD). METHODS AND RESULTS: The WEARIT-France prospective cohort study enrolled heart failure patients with WCD between 2014 and 2018. Night-time was defined as midnight to 7 a.m. NHR initial trajectories were classified into four categories based on mean NHR in the first week (High/Low) and NHR evolution over the second week (Up/Down) of WCD use. The primary endpoint was a composite of cardiovascular death and heart failure hospitalization. A total of 1013 [61 (interquartile range, IQR 53-68) years, 16% women, left ventricular ejection fraction 26% (IQR 22-30)] were included. During a median WCD wear duration of 68 (IQR 44-90) days, 58 patients (6%) experienced 69 events. After considering potential confounders, High-Up NHR trajectory was significantly associated with the primary endpoint compared to Low-Down [adjusted hazard ratio (HR) 6.08, 95% confidence interval (CI) 2.56-14.45, P < 0.001]. Additionally, a rise of >5 bpm in weekly average NHR from the preceding week was associated with 2.5 higher composite event risk (HR 2.51, 95% CI 1.22-5.18, P = 0.012) as well as total mortality (HR 11.21, 95% CI 3.55-35.37, P < 0.001) and cardiovascular hospitalization (HR 2.70, 95% CI 1.51-4.82, P < 0.001). CONCLUSION: Dynamic monitoring of NHR may allow timely identification of impending cardiovascular events, with the potential for 'pre-emptive' action. REGISTRATION NUMBER: Clinical Trials.gov Identifier: NCT03319160.


Assuntos
Insuficiência Cardíaca , Dispositivos Eletrônicos Vestíveis , Humanos , Feminino , Masculino , Estudos de Coortes , Frequência Cardíaca , Estudos Prospectivos , Volume Sistólico/fisiologia , Função Ventricular Esquerda , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Desfibriladores
8.
Europace ; 25(3): 873-879, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36695332

RESUMO

AIMS: The aim of this study was to compare procedural efficacy and safety, including 1-year freedom from AF recurrence, between the novel cryoballoon system PolarX (Boston Scientific) and the Arctic Front Advance Pro (AFA-Pro) (Medtronic), in patients with paroxysmal AF undergoing PVI. METHODS AND RESULTS: This multicentre prospective observational study included 267 consecutive patients undergoing a first cryoablation procedure for paroxysmal AF (137 PolarX, 130 AFA-Pro). Kaplan-Meier curves with the log-rank test was used to compare the 1-year freedom from AF recurrence between both groups. Multivariate Cox model was performed to evaluate whether the type of procedure (PolarX vs. AFA-Pro) had an impact on the occurrence of AF recurrences after adjustment on potentially confounding factors. The PolarX reaches lower temperatures than the AFA-Pro (LSPV 52 ± 5, vs. 59 ± 6; LIPV 49 ± 6 vs. 56 ± 6; right superior pulmonary vein: 49 ± 6 vs. 57 ± 7; right inferior pulmonary vein: 52 ± 6 vs. 59 ± 6; P < 0.0001). A higher rate of transient phrenic nerve palsy was found in patients treated with the PolarX system (15% vs. 7%, P = 0.05). After a mean follow-up of 15 ± 5 months, 20 patients (15%) had recurrences in AFA-Pro group and 27 patients (19%) in PolarX group (P = 0.35). Based on survival analysis, no significant difference was observed between both groups with a 12-month free of recurrence survival of 91.2% (85.1-95.4%) vs. 83.7% (76.0%-89.1%) (log-rank test P = 0.11). In multivariate Cox model hazard ratio of recurrence for PolarX vs. AFA-Pro was not significant [HR = 1.6 (0.9-2.8), P = 0.12]. CONCLUSION: PolarX and AFA-Pro have comparable efficacy and safety profiles for pulmonary veins isolation in paroxysmal atrial fibrillation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/epidemiologia , Resultado do Tratamento , Estudos Prospectivos , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Modelos de Riscos Proporcionais , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Recidiva
9.
Europace ; 24(12): 1952-1959, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36002951

RESUMO

AIMS: Despite recent improvements, inappropriate shocks emitted by implanted subcutaneous implantable cardioverter defibrillators (S-ICDs) remain a challenge in 'real-life' practice. We aimed to study the pre-implant factors associated with inappropriate shocks for the latest generation of S-ICDs. METHODS AND RESULTS: Three-hundred patients implanted with the third-generation S-ICD system for primary or secondary prevention between January 2017 and March 2020 were included in this multicentre retrospective observational study. A follow-up of at least 6 months and pre-implant screening procedure data were mandatory for inclusion. During a mean follow-up of 22.8 (±11.4) months, 37 patients (12.3%) received appropriate S-ICD shock therapy, whereas 26 patients (8.7%) experienced inappropriate shocks (incidence 4.9 per 100 patient years). The total number of inappropriate shock episodes was 48, with nine patients experiencing multiple episodes. The causes of inappropriate shocks included supraventricular arrhythmias (34.6%) and cardiac (30.7%) or extra-cardiac noise (38.4%) oversensing. Using multivariate analysis, we explored the independent factors associated with inappropriate shocks. These were the availability of less than three sensing vectors during pre-implant screening [hazard ratio (HR), 0.33; 95% confidence interval (CI), 0.11-0.93; P = 0.035], low QRS/T wave ratio in Lead I (for a threshold <3; HR, 4.79; 95% CI, 2.00-11.49; P < 0.001), history of supraventricular tachycardia (HR, 8.67; 95% CI, 2.80-26.7; P < 0.001), and being overweight (body mass index > 25; HR, 2.66; 95% CI, 1.10-6.45; P = 0.03). CONCLUSION: Automatic pre-implant screening data are a useful quantitative predictor of inappropriate shocks. Electrocardiogram features should be taken into consideration along with other clinical factors to identify patients at high risk of inappropriate shocks.


Assuntos
Desfibriladores Implantáveis , Taquicardia Supraventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Supraventricular/etiologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Estudos Retrospectivos , Eletrocardiografia , Fatores de Risco
10.
Europace ; 24(1): 165-172, 2022 01 04.
Artigo em Inglês | MEDLINE | ID: mdl-34455442

RESUMO

AIMS: To develop a suite of quality indicators (QIs) for the evaluation of the care and outcomes for adults undergoing cardiac pacing. METHODS AND RESULTS: Under the auspice of the Clinical Practice Guideline Quality Indicator Committee of the European Society of Cardiology (ESC), the Working Group for cardiac pacing QIs was formed. The Group comprised Task Force members of the 2021 ESC Clinical Practice Guidelines on Cardiac Pacing and Cardiac Resynchronization Therapy, members of the European Heart Rhythm Association, international cardiac device experts, and patient representatives. We followed the ESC methodology for QI development, which involved (i) the identification of the key domains of care by constructing a conceptual framework of the management of patients receiving cardiac pacing, (ii) the development of candidate QIs by conducting a systematic review of the literature, (iii) the selection of the final set of QIs using a modified-Delphi method, and (iv) the evaluation of the feasibility of the developed QIs. Four domains of care were identified: (i) structural framework, (ii) patient assessment, (iii) pacing strategy, and (iv) clinical outcomes. In total, seven main and four secondary QIs were selected across these domains and were embedded within the 2021 ESC Guidelines on Cardiac Pacing and Cardiac Resynchronization therapy. CONCLUSION: By way of a standardized process, 11 QIs for cardiac pacing were developed. These indicators may be used to quantify adherence to guideline-recommended clinical practice and have the potential to improve the care and outcomes of patients receiving cardiac pacemakers.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiologia , Marca-Passo Artificial , Adulto , Comitês Consultivos , Terapia de Ressincronização Cardíaca/efeitos adversos , Humanos , Indicadores de Qualidade em Assistência à Saúde
11.
Circulation ; 142(17): 1612-1622, 2020 10 27.
Artigo em Inglês | MEDLINE | ID: mdl-32998542

RESUMO

BACKGROUND: Tetralogy of Fallot (TOF) is the most common cyanotic congenital heart disease, and sudden cardiac death represents an important mode of death in these patients. Data evaluating the implantable cardioverter defibrillator (ICD) in this patient population remain scarce. METHODS: A Nationwide French Registry including all patients with tetralogy of Fallot with an ICD was initiated in 2010 by the French Institute of Health and Medical Research. The primary time to event end point was the time from ICD implantation to first appropriate ICD therapy. Secondary outcomes included ICD-related complications, heart transplantation, and death. Clinical events were centrally adjudicated by a blinded committee. RESULTS: A total of 165 patients (mean age, 42.2±13.3 years, 70.1% males) were included from 40 centers, including 104 (63.0%) in secondary prevention. During a median (interquartile range) follow-up of 6.8 (2.5-11.4) years, 78 (47.3%) patients received at least 1 appropriate ICD therapy. The annual incidence of the primary outcome was 10.5% (7.1% and 12.5% in primary and secondary prevention, respectively; P=0.03). Overall, 71 (43.0%) patients presented with at least 1 ICD complication, including inappropriate shocks in 42 (25.5%) patients and lead dysfunction in 36 (21.8%) patients. Among 61 (37.0%) patients in primary prevention, the annual rate of appropriate ICD therapies was 4.1%, 5.3%, 9.5%, and 13.3% in patients with, respectively, 0, 1, 2, or ≥3 guidelines-recommended risk factors. QRS fragmentation was the only independent predictor of appropriate ICD therapies (hazard ratio, 3.47 [95% CI, 1.19-10.11]), and its integration in a model with current criteria increased the 5-year time-dependent area under the curve from 0.68 to 0.81 (P=0.006). Patients with congestive heart failure or reduced left ventricular ejection fraction had a higher risk of nonarrhythmic death or heart transplantation (hazard ratio, 11.01 [95% CI, 2.96-40.95]). CONCLUSIONS: Patients with tetralogy of Fallot and an ICD experience high rates of appropriate therapies, including those implanted in primary prevention. The considerable long-term burden of ICD-related complications, however, underlines the need for careful candidate selection. A combination of easy-to-use criteria including QRS fragmentation might improve risk stratification. Registration: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03837574.


Assuntos
Desfibriladores Implantáveis/tendências , Tetralogia de Fallot/epidemiologia , Tetralogia de Fallot/terapia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Sistema de Registros
12.
J Cardiovasc Electrophysiol ; 32(6): 1584-1593, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33772926

RESUMO

BACKGROUND: The assessment of noninvasive markers of left atrial (LA) low-voltage substrate (LVS) enables the identification of atrial fibrillation (AF) patients at risk for arrhythmia recurrence after pulmonary vein isolation (PVI). METHODS: In this prospective multicenter study, 292 consecutive AF patients (72% male, 62 ± 11 years, 65% persistent AF) underwent high-density LA voltage mapping in sinus rhythm. LA-LVS (<0.5 mV) was considered as significant at 2 cm2  or above. Preprocedural clinical electrocardiogram and echocardiographic data were assessed to identify predictors of LA-LVS. The role of the identified LA-LVS markers in predicting 1-year arrhythmia freedom after PVI was assessed in 245 patients. RESULTS: Significant LA-LVS was identified in 123 (42%) patients. The amplified sinus P-wave duration (APWD) best predicted LA-LVS, with a 148-ms value providing the best-balanced sensitivity (0.81) and specificity (0.88). An APWD over 160 ms was associated with LA-LVS in 96% of patients, whereas an APWD under 145 ms in 15%. Remaining gray zones improved their accuracy by introduction of systolic pulmonary artery pressure (sPAP) of 35 mmHg or above, age, and sex. According to COX regression, the risk of arrhythmia recurrence 12 months following PVI was twofold and threefold higher in patients with APWD 145-160 and over 160 ms, compared to APWD under 145 ms. Integration of pulmonary hypertension further improved the outcome prediction in the intermediate APWD group: Patients with APWD 145-160 ms and normal sPAP had similar outcome than patients with APWD under 145 ms (hazard ratio [HR] 1.62, p = .14), whereas high sPAP implied worse outcome (HR 2.56, p < .001). CONCLUSIONS: The APWD identifies LA-LVS and risk for arrhythmia recurrence after PVI. Our prediction model becomes optimized by means of integration of the pulmonary artery pressure.


Assuntos
Fibrilação Atrial , Remodelamento Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ecocardiografia , Eletrocardiografia , Feminino , Átrios do Coração/diagnóstico por imagem , Humanos , Masculino , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 98(4): 788-799, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34051135

RESUMO

OBJECTIVES: The French left atrial appendage (LAA) closure registry (FLAAC) aimed to assess the safety and efficacy of LAA closure in daily practice. BACKGROUND: LAA closure has emerged as an alternative for preventing thromboembolic events (TE) in patients with non-valvular atrial fibrillation (NVAF). Clinical data in this field remains limited and few investigator-initiated, real-world registries have been reported. METHODS: This nationwide, prospective study was performed in 36 French centers. The primary endpoint was the TE rate after successful LAA closure. RESULTS: The FLAAC registry included 816 patients with a mean age of 75.5 ± 0.3 years, mean follow-up of 16.0 ± 0.3 months, high TE (CHA2 DS2 -VASc score: 4.6 ± 0.1) and bleeding risks (HAS-BLED score: 3.2 ± 0.05) and common contraindications to long-term anticoagulation (95.7%). Procedure or device-related serious adverse events occurred in 49 (6.0%) patients. The annual rate of ischemic stroke/systemic embolism was 3.3% (2.4-4.6). This suggests a relative 57% reduction compared to the risk of stroke in historical NVAF populations without antithrombotic therapy. By multivariate analysis, history of TE was the only factor associated with stroke/systemic embolism during follow-up (HR, 3.3 [1.58-6.89], p = 0.001). The annual mortality rate was 10.2% (8.4-12.3). Most of the deaths were due to comorbidities or underlying cardiovascular diseases and unrelated to the device or to TE. CONCLUSIONS: Our study suggests that LAA closure can be an option in patients with NVAF. Long-term follow-up mortality was high, mostly due to comorbidities and underlying cardiovascular diseases, highlighting the importance of multidisciplinary management after LAA closure. REGISTRATION: NCT02252861.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Idoso , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Humanos , Estudos Prospectivos , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
14.
Europace ; 23(5): 740-747, 2021 05 21.
Artigo em Inglês | MEDLINE | ID: mdl-33313789

RESUMO

AIMS: Totally leadless cardiac resynchronization therapy (CRT) can be delivered with a combination of Micra and WiSE-CRT systems. We describe the technical feasibility and first insights into the safety and efficacy of this combination in European experience. METHODS AND RESULTS: Patients enrolled had indication for both Micra and WiSE-CRT systems because of heart failure related to high burden of pacing by a Micra necessitating system upgrade or inability to implant a conventional CRT system because of infectious or anatomical conditions. The endpoints of the study were technical success of WiSE-CRT implantation with right ventricle-synchonized CRT delivery, acute QRS duration reduction, and freedom from procedure-related major adverse events. All eight WiSE-CRT devices were able to detect the Micra pacing output and to be trained to deliver synchronous LV endocardial pacing. Acute QRS reduction following WiSE-CRT implantation was observed in all eight patients (mean QRS 204.38 ± 30.26 vs. 137.5 ± 24.75 mS, P = 0.012). Seven patients reached 6 months of follow-up. At 6 months after WiSE-CRT implantation, there was a significant increase in LV ejection fraction (28.43 ± 8.01% vs. 39.71 ± 11.89%; P = 0.018) but no evidence of LV reverse remodelling or improvement in New York Heart Association class. CONCLUSION: The Micra and the WiSE-CRT systems can successfully operate together to deliver total leadless CRT to a patient. Moreover, the WiSE-CRT system provides the only means to upgrade the large population of Micra patients to CRT capability without replacing the Micra. The range of application of this combination could broaden in the future with the upcoming developments of leadless cardiac pacing.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Marca-Passo Artificial , Dispositivos de Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Resultado do Tratamento
15.
Europace ; 23(3): 389-394, 2021 03 08.
Artigo em Inglês | MEDLINE | ID: mdl-33257986

RESUMO

AIMS: FRench Attitude reGistry in case of ICD LEad replacement (FRAGILE) registry was set-up to describe the attitude in different French institutions in case of implantable cardioverter-defibrillator (ICD) lead replacement, extraction, or abandonment and to compare outcomes in both groups. METHODS AND RESULTS: Prospective observational study comparing two attitudes in case of ICD lead replacement, extraction, or abandonment. Primary endpoint describes the attitude in different French centres, collect parameters that may influence the decision. Secondary endpoint compares early and mid-term (2 years) complications in both groups.Between April 2013 and April 2017, 552 patients were included in 32 centres. 434 (78.6%) were male, mean patient's age was 60.3 ± 14.4 years. In 56.9% of the cases, the decision was to explant the lead. Patients in the extraction group were younger than in the abandonment group (56.7 ± 14.5 vs. 65 ± 12.7 P < 0.0001) and less likely to have comorbidities (46.5% vs. 58.3% of the patients P = 0.022). The mean lead dwelling time was significantly longer in the abandonment group as compared with the extraction group (7.6 ± 3.9 vs. 5.2 ± 3.1 years, P < 0.0001). There was no statistical difference between both groups concerning early and 2 years complications. CONCLUSION: In this registry, the strategy in case of non-infected ICD lead replacement was mainly influenced by patient's age and comorbidities and lead dwelling time. No difference was observed in outcomes in both strategies.


Assuntos
Desfibriladores Implantáveis , Idoso , Atitude , Remoção de Dispositivo , Cardioversão Elétrica , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros
16.
Europace ; 23(10): 1577-1585, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322707

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) upgrades may be less likely to improve following intervention. Leadless left ventricular (LV) endocardial pacing has been used for patients with previously failed CRT or high-risk upgrades. We compared procedural and long-term outcomes in patients undergoing coronary sinus (CS) CRT upgrades with high-risk and previously failed CRT upgrades undergoing LV endocardial upgrades. METHOD AND RESULTS: Prospective consecutive CS upgrades between 2015 and 2019 were compared with those undergoing WiSE-CRT implantation. Cardiac resynchronization therapy response at 6 months was defined as improvement in clinical composite score (CCS) and a reduction in LV end-systolic volume (LVESV) ≥15%. A total of 225 patients were analysed; 121 CS and 104 endocardial upgrades. Patients receiving WiSE-CRT tended to have more comorbidities and were more likely to have previous cardiac surgery (30.9% vs. 16.5%; P = 0.012), hypertension (59.2% vs. 34.7%; P < 0.001), chronic obstructive airways disease (19.4% vs. 9.9%; P = 0.046), and chronic kidney disease (46.4% vs. 21.5%; P < 0.01) but similar LV ejection fraction (30.0 ± 8.3% vs. 29.5 ± 8.6%; P = 0.678). WiSE-CRT upgrades were successful in 97.1% with procedure-related mortality in 1.9%. Coronary sinus upgrades were successful in 97.5% of cases with a 2.5% rate of CS dissection and 5.6% lead malfunction/displacement. At 6 months, 91 WiSE-CRT upgrades and 107 CS upgrades had similar improvements in CCS (76.3% vs. 68.5%; P = 0.210) and reduction in LVESV ≥15% (54.2% vs. 56.3%; P = 0.835). CONCLUSION: Despite prior failed upgrades and high-risk patients with more comorbidities, WiSE-CRT upgrades had high rates of procedural success and similar improvements in CCS and LV remodelling with CS upgrades.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Insuficiência Cardíaca , Seio Coronário/diagnóstico por imagem , Endocárdio , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
17.
Europace ; 23(7): 983-1008, 2021 07 18.
Artigo em Inglês | MEDLINE | ID: mdl-33878762

RESUMO

With the global increase in device implantations, there is a growing need to train physicians to implant pacemakers and implantable cardioverter-defibrillators. Although there are international recommendations for device indications and programming, there is no consensus to date regarding implantation technique. This document is founded on a systematic literature search and review, and on consensus from an international task force. It aims to fill the gap by setting standards for device implantation.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Ásia , Consenso , Humanos , Estados Unidos
18.
Europace ; 23(4): 494-495, 2021 04 06.
Artigo em Inglês | MEDLINE | ID: mdl-32860039

RESUMO

AIMS: To develop quality indicators (QIs) that may be used to evaluate the quality of care and outcomes for adults with atrial fibrillation (AF). METHODS AND RESULTS: We followed the ESC methodology for QI development. This methodology involved (i) the identification of the domains of AF care for the diagnosis and management of AF (by a group of experts including members of the ESC Clinical Practice Guidelines Task Force for AF); (ii) the construction of candidate QIs (including a systematic review of the literature); and (iii) the selection of the final set of QIs (using a modified Delphi method). Six domains of care for the diagnosis and management of AF were identified: (i) Patient assessment (baseline and follow-up), (ii) Anticoagulation therapy, (iii) Rate control strategy, (iv) Rhythm control strategy, (v) Risk factor management, and (vi) Outcomes measures, including patient-reported outcome measures (PROMs). In total, 17 main and 17 secondary QIs, which covered all six domains of care for the diagnosis and management of AF, were selected. The outcome domain included measures on the consequences and treatment of AF, as well as PROMs. CONCLUSION: This document defines six domains of AF care (patient assessment, anticoagulation, rate control, rhythm control, risk factor management, and outcomes), and provides 17 main and 17 secondary QIs for the diagnosis and management of AF. It is anticipated that implementation of these QIs will improve the quality of AF care.


Assuntos
Fibrilação Atrial , Adulto , Comitês Consultivos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Humanos , Indicadores de Qualidade em Assistência à Saúde , Fatores de Risco , Revisões Sistemáticas como Assunto
19.
Europace ; 23(1): 73-81, 2021 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-33257972

RESUMO

AIMS: We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. METHODS AND RESULTS: Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37-97) days. Median daily wear time of WCD was 23.4 (22.2-23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95-0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). CONCLUSION: Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.


Assuntos
Desfibriladores Implantáveis , Dispositivos Eletrônicos Vestíveis , Idoso , Estudos de Coortes , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores , Cardioversão Elétrica , Feminino , França/epidemiologia , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento
20.
Europace ; 22(4): 667-673, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31960027

RESUMO

To study the proportion of leadless pacemaker (LL-PM) implants and the factors influencing the choice of LL-PM vs. transvenous pacemaker (TV-PM) across tertiary centres in Europe with routine availability of the LL-PM. A European Heart Rhythm Association (EHRA) prospective snapshot survey using electronically distributed questionnaire sent to participating centres. Participating tertiary cardiac pacing centres prospectively included consecutive patients implanted between November 2018 and January 2019. Questions covered standards of care and policies used for patient management, focusing particularly on the reasons for choosing LL-PM vs. TV-PM. Overall, 21 centres from four countries (France, Netherlands, Spain, and Italy) participated, with eventual data from 798 patients (n = 472, 59% male). With 69 implants, LL-PM represented only 9% of all implants and 36% of the single-chamber pacing group; double-chamber transvenous pacemakers were implanted in 528 patients and biventricular (cardiac resynchronization pacemaker) in 79. The two major reasons reported in favour of LL-PM implantation were an anticipated high risk of infection or low rate of ventricular pacing. Compared to TV-PM, LL-PM patients were more often male (74% vs. 54%, P = 0.009), with greater proportion of valvular heart disease (45% vs. 35%, P = 0.01) and atrial fibrillation (AF; 65% vs. 23%, P < 0.0001), with significantly more comorbidities (≥ one comorbidity, 66% vs. 52%, P = 0.02). This contemporary multicentre European survey shows that LL-PM constitutes a small proportion of all PM implants. Patients implanted with LL-PM were more likely to have AF and a high anticipated risk of infection.


Assuntos
Marca-Passo Artificial , Estimulação Cardíaca Artificial , Europa (Continente) , Feminino , França , Humanos , Itália , Masculino , Países Baixos , Estudos Prospectivos , Espanha , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS