Europace ; 2024 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-39082698

RESUMO

Cardioneuroablation has emerged as a potential alternative to cardiac pacing in selected cases with vasovagal reflex syncope, extrinsic vagally induced sinus bradycardia-arrest or atrioventricular block. The technique was first introduced decades ago, and its use has risen over the past decade. However, as with any intervention, proper patient selection and technique are a prerequisite for a safe and effective use of cardioneuroablation therapy. This document aims to review and interpret available scientific evidence and provide a summary position on the topic.

4.
Front Cardiovasc Med ; 11: 1361761, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38572304

RESUMO

Background and aims: Right phrenic nerve palsy is the most frequent complication of cryoballoon procedures. The SMARTFREEZE™ console (Boston Scientific, St. Paul, MN, USA) has integrated a new tool for diaphragm monitoring-the Diaphragm Movement Sensor; however, it has not been evaluated in clinical practice. We aimed to assess the diagnostic performance of the Diaphragm Movement Sensor based on compound motor action potential data recorded simultaneously. Methods: Thirty consecutive patients (mean age 63.2 ± 10.2 years) were included. We simultaneously recorded the compound motor action potential and the Diaphragm Movement Sensor during cryoapplications in the right pulmonary veins. The right phrenic nerve was paced at 60 per minute, 12 V and 2.9 ms. Compound motor action potential monitoring with a 30% decrease cutoff for the diagnosis of phrenic nerve threatening was considered the gold standard. The Diaphragm Movement Sensor decrease threshold was also set at 30%. Results: Considering compound motor action potential monitoring, phrenic nerve threatening occurred 11 times (in seven patients) among 84 cryoapplications (13.1%) at the right pulmonary veins. The sensitivity and specificity of the Diaphragm Movement Sensor were, respectively, 33% (95% CI: 7%-70%) and 49% (95% CI: 38%-61%; P < 0.001). The predictive positive and negative values for the Diaphragm Movement Sensor were, respectively, 7% (95% CI: 2%-20%) and 86% (95% CI: 72%-95%). The Diaphragm Movement Sensor gave an erroneous diagnosis in 44/84 cryoapplications (52.4%). Conclusions: The diagnostic performance of the Diaphragm Movement Sensor is low, and the relevance of its use in clinical practice may be debated.

5.
Mayo Clin Proc ; 99(5): 754-765, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38180394

RESUMO

OBJECTIVE: To compare outcomes after left atrial appendage occlusion (LAAO) via implanted device vs no LAAO in a matched cohort of patients with atrial fibrillation (AF). METHODS: This longitudinal retrospective cohort study was based on the national database covering hospital care for the entire French population. Adults (≥18 years of age) who had been hospitalized with AF (January 1, 2015, to January 1, 2020) who underwent LAAO were identified. Propensity score matching was used to control for potential confounders of the treatment-outcome relationship. The primary outcome was a composite of ischemic stroke, major bleeding, or all-cause death during follow-up. RESULTS: After propensity score matching, 1216 patients with AF who were treated with LAAO were matched with 1216 controls (patients AF who were not treated with LAAO). Mean follow-up was 14.5 months (median, 13 months; IQR, 7-21 months). Patients with LAAO had a lower risk of the composite outcome (HR, 0.48; 95% CI, 0.42 to 0.55). Total events (309 for LAAO vs 640 for controls) and event rates (23.3% vs 44.0%/year, respectively) were lower for LAAO, driven primarily by a decreased risk of all-cause death (HR, 0.39; 95% CI, 0.33 to 0.46; P<.0001), whereas ischemic stroke risk was higher (HR, 1.75; 95% CI, 1.17 to 2.64). Significant interactions were observed in subgroups with a history of ischemic stroke (P<.001) and of bleeding (P=.002). CONCLUSION: Among AF patients at high bleeding risk, our nationwide study highlights a high risk of clinical events during follow-up. LAAO appeared less effective than no LAAO in preventing stroke but more effective in preventing death. Left atrial appendage occlusion is particularly effective in patients with previous ischemic stroke or any episode of bleeding.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Fibrilação Atrial/cirurgia , Apêndice Atrial/cirurgia , Masculino , Feminino , Idoso , Estudos Retrospectivos , Pontuação de Propensão , Estudos Longitudinais , Pessoa de Meia-Idade , Resultado do Tratamento , Dispositivo para Oclusão Septal , AVC Isquêmico/prevenção & controle , AVC Isquêmico/etiologia , AVC Isquêmico/epidemiologia , Idoso de 80 Anos ou mais , França/epidemiologia
6.
Arch Cardiovasc Dis ; 117(6-7): 450-456, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38677940

RESUMO

In France, mexiletine - a class I antiarrhythmic drug - can be prescribed for the symptomatic treatment of myotonia of the skeletal muscles in adult patients with myotonic dystrophy under a compassionate use programme. Mexiletine is used according to its summary of product characteristics, which describes its use for myotonia treatment in adult patients with non-dystrophic myotonia, a different neuromuscular condition without cardiac involvement. A cardiac assessment is required prior to initiation and throughout treatment due to potential proarrhythmic effects. The presence of conduction system disease, the most common cardiac manifestation of myotonic dystrophy, mandates repeated cardiac evaluations in patients with this condition, and becomes even more important when they are given mexiletine. A group of experts, including three neurologists and five cardiologists from French neuromuscular reference centres, were involved in a task force to develop a treatment algorithm to guide mexiletine use in myotonic dystrophy. The recommendations are based on data from a literature review of the safety of mexiletine-treated patients with myotonic dystrophy, the compassionate use protocol for mexiletine and the personal clinical experience of the experts. The main conclusion of the expert group is that, although existing safety data in mexiletine-treated patients with myotonic dystrophy are reassuring, cardiac assessments should be reinforced in such patients compared with mexiletine-treated patients with non-dystrophic myotonia. This expert opinion to guide mexiletine treatment in patients with myotonic dystrophy should help to reduce the risk of severe adverse events and facilitate interactions between specialists involved in the routine care of patients with myotonic dystrophy.


Assuntos
Mexiletina , Distrofia Miotônica , Adulto , Humanos , Algoritmos , Antiarrítmicos/uso terapêutico , Antiarrítmicos/efeitos adversos , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/induzido quimicamente , Tomada de Decisão Clínica , Ensaios de Uso Compassivo , Consenso , França , Mexiletina/uso terapêutico , Mexiletina/efeitos adversos , Distrofia Miotônica/tratamento farmacológico , Distrofia Miotônica/diagnóstico , Distrofia Miotônica/fisiopatologia , Medição de Risco , Fatores de Risco , Resultado do Tratamento , Bloqueadores do Canal de Sódio Disparado por Voltagem/uso terapêutico , Bloqueadores do Canal de Sódio Disparado por Voltagem/efeitos adversos
7.
Arch Cardiovasc Dis ; 117(5): 304-312, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38704289

RESUMO

BACKGROUND: Aortic valve infective endocarditis may be complicated by high-degree atrioventricular block in up to 10-20% of cases. AIM: To assess high-degree atrioventricular block occurrence, contributing factors, prognosis and evolution in patients referred for aortic infective endocarditis. METHODS: Two hundred and five patients referred for aortic valve infective endocarditis between January 2018 and March 2021 were included in this study. A comprehensive assessment of clinical, electrocardiographic, biological, microbiological and imaging data was conducted, with a follow-up carried out over 1 year. RESULTS: High-degree atrioventricular block occurred in 22 (11%) patients. In univariate analysis, high-degree atrioventricular block was associated with first-degree heart block at admission (odds ratio 3.1; P=0.015), periannular complication on echocardiography (odds ratio 6.9; P<0.001) and severe biological inflammatory syndrome, notably C-reactive protein (127 vs 90mg/L; P=0.011). In-hospital mortality (12.7%) was higher in patients with high-degree atrioventricular block (odds ratio 4.0; P=0.011) in univariate analysis. Of the 16 patients implanted with a permanent pacemaker for high-degree atrioventricular block and interrogated, only four (25%) were dependent on the pacing function at 1-year follow-up. CONCLUSIONS: High-degree atrioventricular block is associated with high inflammation markers and periannular complications, especially if first-degree heart block is identified at admission. High-degree atrioventricular block is a marker of infectious severity, and tends to raise the in-hospital mortality rate. Systematic assessment of patients admitted for infective endocarditis suspicion, considering these contributing factors, could indicate intensive care unit monitoring or even temporary pacemaker implantation in those at highest risk.


Assuntos
Valva Aórtica , Bloqueio Atrioventricular , Mortalidade Hospitalar , Marca-Passo Artificial , Humanos , Masculino , Feminino , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/etiologia , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/mortalidade , Pessoa de Meia-Idade , Idoso , Fatores de Risco , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/microbiologia , Fatores de Tempo , Endocardite/mortalidade , Endocardite/diagnóstico , Endocardite/complicações , Estimulação Cardíaca Artificial , Estudos Retrospectivos , Adulto , Medição de Risco , Eletrocardiografia , Frequência Cardíaca , Idoso de 80 Anos ou mais , Sistema de Condução Cardíaco/fisiopatologia
8.
Int J Cardiol ; 408: 132118, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38697397

RESUMO

BACKGROUND: To assess long-term effectiveness and safety of edoxaban in Europe. METHODS AND RESULTS: ETNA-AF-Europe, a prospective, multinational, multi-centre, post-authorisation, observational study was conducted in agreement with the European Medicines Agency. The primary and secondary objectives assessed real-world safety (including bleeding and deaths) and effectiveness (including stroke, systemic embolic events and clinical edoxaban use), respectively. Median (interquartile range) age of the 13,164 patients was 75.0 (68.0-80.0) years; CHA2DS2-VASc and HAS-BLED scores were 3.0 (2.0-4.0) and 2.0 (1.0-2.0), respectively. Follow-up duration was 3.98 (3.21-4.05) years. Patients on edoxaban 30 mg (n = 3042) at baseline were older (80.0 vs 73.0 years), more likely assessed as frail by investigators (27.0% vs 6.6%) and had more comorbidities than those on edoxaban 60 mg (n = 9617; missing dosing information for n = 505). Annualised event rates of all-cause and cardiovascular death in the overall population, edoxaban 60 mg and edoxaban 30 mg groups were 4.1%, 2.8% and 8.4%, and 1.0%, 0.7% and 2.0%, respectively. Annualised rates of stroke were relatively constant throughout the follow-up, transient ischaemic attack and systemic embolism were < 1% in the overall population. Rates of any major and major gastrointestinal bleeding were low, with slightly higher rates for edoxaban 30 vs 60 mg group. Intracranial haemorrhage was uncommon (0.2%). CONCLUSIONS: In European patients with AF, long-term therapy with edoxaban is associated with low and relatively constant annualised rates of stroke and major bleeding. Differences in outcomes between the two approved doses are attributable to differences in clinical characteristics.


Assuntos
Fibrilação Atrial , Inibidores do Fator Xa , Piridinas , Tiazóis , Humanos , Tiazóis/efeitos adversos , Tiazóis/uso terapêutico , Tiazóis/administração & dosagem , Piridinas/efeitos adversos , Piridinas/administração & dosagem , Piridinas/uso terapêutico , Idoso , Fibrilação Atrial/tratamento farmacológico , Masculino , Feminino , Europa (Continente)/epidemiologia , Estudos Prospectivos , Inibidores do Fator Xa/efeitos adversos , Inibidores do Fator Xa/administração & dosagem , Inibidores do Fator Xa/uso terapêutico , Idoso de 80 Anos ou mais , Resultado do Tratamento , Seguimentos , Fatores de Tempo , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/epidemiologia , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia
9.
Heart Rhythm ; 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38810921

RESUMO

BACKGROUND: Electrocardiographic screening before subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation is unsuccessful in around 10% of cases. A personalized screening method, by slightly moving the electrodes, to obtain a better R/T ratio has been described to overcome traditional screening failure. OBJECTIVE: The objectives of the SIS study were to assess to what extent a personalized screening method improves eligibility for S-ICD implantation and to evaluate the inappropriate shock rate after such screening success. METHODS: All consecutive patients eligible for an S-ICD implantation were prospectively recruited across 20 French centers between December 2019 and January 2022. In case of traditional screening failure, patients received a second personalized screening. If at least 1 vector was positive, the personalized screening was considered successful, and the patient was eligible for implantation. RESULTS: The study included 474 patients (mean age, 50.4 ± 14.1 years; 77.4% men). Traditional screening was successful in 456 (96.2%) cases. This figure rose to 98.3% (n = 466; P = .002) when personalized screening was performed. All patients implanted after successful personalized screening had correct signal detection on initial device interrogation. Nevertheless, after 1-year follow-up, 3 of the 7 patients (43%) implanted with personalized screening experienced inappropriate shock vs 18 of the 427 patients (4.2%) with traditional screening and S-ICD implantation (P = .003). CONCLUSION: Traditional S-ICD screening was successful in our study in a high proportion of patients. Considering the small improvement in success of screening and a higher rate of inappropriate shock, a strategy of personalized screening cannot be routinely recommended. CLINICALTRIALS: gov identifier: NCT04101253.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38970599

RESUMO

BACKGROUND: Idiopathic ventricular fibrillation (IVF) can be associated with undetected distinct conditions such as microstructural cardiomyopathic alterations (MiCM) or Purkinje (Purk) activities with structurally normal hearts. OBJECTIVE: This study sought to evaluate the characteristics of recurrent VF recorded on implantable defibrillator electrograms, associated with these substrates. METHODS: This was a multicenter collaboration study. At 32 centers, we selected patients with an initial diagnosis of IVF and recurrent arrhythmia at follow-up without antiarrhythmic drugs, in whom mapping demonstrated Purk or MiCM substrate. We analyzed variables related to previous ectopy, sinus rate preceding VF, trigger, and initial VF cycle lengths. Logistic regression with cross validation was used to evaluate the performance of criteria to discriminate Purk or MiCM substrates. RESULTS: Among 95 patients (35 women, age 35 ± 11 years) meeting the inclusion criteria, IVF was associated with MiCM in 41 and Purk in 54 patients. A total of 117 arrhythmia recurrences including 91% VF were recorded on defibrillator. Three variables were mostly discriminant. Sinus tachycardia (≤570 ms) was more frequent in MiCM (35.9% vs 13.4%, P = 0.014) whereas short-coupled (<350 ms) triggers were most frequent in Purk-related VF (95.5% vs 23.1%, P = 0.001), which also had shorter VFCLs (182 ± 15 ms vs 215 ± 24 ms, P < 0.001).The multivariable combination provided the highest prediction (accuracy = 0.93 ± 0.05, range 0.833-1.000), discriminating 81% of IVF substrates with a high probability (>80%). Ectopy were inconsistently present before VF. CONCLUSIONS: Characteristics of arrhythmia recurrences on implantable cardioverter- defibrillator provide phenotypic markers of the distinct and hidden substrates underlying IVF. These findings have significant clinical and genetic implications.