Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 152
Filtrar
1.
Microb Pathog ; 179: 106080, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36948364

RESUMO

BACKGROUND & AIMS: Hemodialysis (HD) is a life-saving procedure that purifies the blood in patients with end-stage renal disease (ESRD). Among all major complications, blood-borne diseases like hepatitis B virus (HBV) may be exposed as serious side effects of hemodialysis. A comprehensive review of the global burden of HBV among HD patients has not been written so far. The aim of the current systematic review and meta-analysis was to determine the globally epidemiology of HBV infection among HD patients. METHODS: Based on the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines, articles that investigated the prevalence of HBV among HD patients were searched from the major databases such as EMBASE, PubMed, Web of Science collection, and Scopus. Pooled prevalence with 95% CI and identification of heterogeneity were obtained using the random effects model and Cochran's Q-test, respectively, and quantification was evaluated using the I2 statistics. All statistical analyses were performed by STATA 14.1 statistical software. RESULTS: among 322 datasets (795,623 cases) that included in this study, the pooled prevalence of HBV infection among HD patients was 7.32% (95% CI: 6.53-8.15%; I2 = 97.91%), including 7.57% (95% CI: 6.69-8.48%) for HBsAg and 6.09% (95% CI: 4.05-8.49%) for DNA, respectively. In addition, based on geographic area, the prevalence was 7.44% (95% CI: 6.35-8.61%) in Asia, 4.32% (95% CI: 2.21-7.04%) in North America, 7.07% (95% CI: 6.35-8.61%) in Europe, 5.52% (95% CI: 3.60-7.78%) in Africa, 8.45% (95% CI: 5.81-11.78%) in Oceania, and 9.73% (95% CI: 7.11-12.70%) in South America. CONCLUSIONS: Our analysis indicates a relatively high prevalence of HBV infection in HD patients, even in some developed countries. Considering that ESRD patients are not able to properly respond to the vaccination strategies in order to develop an acceptable immunity, vaccination of healthy individuals is highly recommended to arm their bodies for possible immunocompromise conditions in the future. Moreover, donated blood in blood transfusion centers should be checked for possible hepatitis B virus infection using sensitive molecular tests.


Assuntos
Hepatite B , Falência Renal Crônica , Humanos , Vírus da Hepatite B/genética , Hepatite B/epidemiologia , Diálise Renal/efeitos adversos , Falência Renal Crônica/complicações , Falência Renal Crônica/epidemiologia , Falência Renal Crônica/terapia , Antígenos de Superfície da Hepatite B , Prevalência
2.
Theor Appl Genet ; 133(9): 2545-2554, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32494869

RESUMO

KEY MESSAGE: A locus for perennial growth was mapped on Lophopyrum elongatum chromosome arm 4ES and introgressed into the wheat genome. Evidence was obtained that in addition to chromosome 4E, other L. elongatum chromosomes control perennial growth. Monocarpy versus polycarpy is one of the fundamental developmental dichotomies in flowering plants. Advances in the understanding of the genetic basis of this dichotomy are important for basic biological reasons and practically for genetic manipulation of growth development in economically important plants. Nine wheat introgression lines (ILs) harboring germplasm of the Lophopyrum elongatum genome present in the octoploid amphiploid Triticum aestivum cv. Chinese Spring (subgenomes AABBDD) × L. elongatum (genomes EE) were selected from a population of ILs developed earlier. These ILs were employed here in genomic analyses of post-sexual cycle regrowth (PSCR), which is a component of polycarpy in caespitose L. elongatum. Analyses of disomic substitution (DS) lines confirmed that L. elongatum chromosome 4E confers PSCR on wheat. The gene was mapped into a short distal region of L. elongatum arm 4ES and was tentatively named Pscr1. ILs harboring recombined chromosomes with 4ES segments, including Pscr1, incorporated into the distal part of the 4DS chromosome arm were identified. Based on the location, Pscr1 is not orthologous with the rice rhizome-development gene Rhz2 located on rice chromosome Os3, which is homoeologous with chromosome 4E, but it may correspond to the Teosinte branched1 (TB1) gene, which is located in the introgressed region in the L. elongatum and Ae. tauschii genomes. A hexaploid IL harboring a large portion of the E-genome but devoid of chromosome 4E also expressed PSCR, which provided evidence that perennial growth is controlled by genes on other L. elongatum chromosomes in addition to 4E.


Assuntos
Genes de Plantas , Melhoramento Vegetal , Poaceae/crescimento & desenvolvimento , Triticum/genética , Mapeamento Cromossômico , Cromossomos de Plantas , Genótipo , Poaceae/genética , Polimorfismo de Nucleotídeo Único , Poliploidia
3.
Plant J ; 95(3): 487-503, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29770515

RESUMO

Homology was searched with genes annotated in the Aegilops tauschii pseudomolecules against genes annotated in the pseudomolecules of tetraploid wild emmer wheat, Brachypodium distachyon, sorghum and rice. Similar searches were performed with genes annotated in the rice pseudomolecules. Matrices of collinear genes and rearrangements in their order were constructed. Optical BioNano genome maps were constructed and used to validate rearrangements unique to the wild emmer and Ae. tauschii genomes. Most common rearrangements were short paracentric inversions and short intrachromosomal translocations. Intrachromosomal translocations outnumbered segmental intrachromosomal duplications. The densities of paracentric inversion lengths were approximated by exponential distributions in all six genomes. Densities of collinear genes along the Ae. tauschii chromosomes were highly correlated with meiotic recombination rates but those of rearrangements were not, suggesting different causes of the erosion of gene collinearity and evolution of major chromosome rearrangements. Frequent rearrangements sharing breakpoints suggested that chromosomes have been rearranged recurrently at some sites. The distal 4 Mb of the short arms of rice chromosomes Os11 and Os12 and corresponding regions in the sorghum, B. distachyon and Triticeae genomes contain clusters of interstitial translocations including from 1 to 7 collinear genes. The rates of acquisition of major rearrangements were greater in the large wild emmer wheat and Ae. tauschii genomes than in the lineage preceding their divergence or in the B. distachyon, rice and sorghum lineages. It is suggested that synergy between large quantities of dynamic transposable elements and annual growth habit have been the primary causes of the fast evolution of the Triticeae genomes.


Assuntos
Evolução Molecular , Genoma de Planta/genética , Genômica , Poaceae/genética , Aegilops/genética , Brachypodium/genética , Mapeamento Cromossômico , Genes de Plantas/genética , Oryza/genética , Análise de Sequência de DNA , Sorghum/genética , Triticum/genética
4.
J Am Chem Soc ; 140(32): 10242-10249, 2018 08 15.
Artigo em Inglês | MEDLINE | ID: mdl-30032598

RESUMO

The development of long-lived luminescent nanoparticles for lifetime imaging is of wide interest as luminescence lifetime is environmentally sensitive detection independent of probe concentration. We report novel iridium-coated gold nanoparticles as probes for multiphoton lifetime imaging with characteristic long luminescent lifetimes based on iridium luminescence in the range of hundreds of nanoseconds and a short signal on the scale of picoseconds based on gold allowing multichannel detection. The tailor-made IrC6 complex forms stable, water-soluble gold nanoparticles (AuNPs) of 13, 25, and 100 nm, bearing 1400, 3200, and 22 000 IrC6 complexes per AuNP, respectively. The sensitivity of the iridium signal on the environment of the cell is evidenced with an observed variation of lifetimes. Clusters of iridium nanoparticles show lifetimes from 450 to 590 ns while lifetimes of 660 and 740 ns are an average of different points in the cytoplasm and nucleus. Independent luminescence lifetime studies of the nanoparticles in different media and under aggregation conditions postulate that the unusual long lifetimes observed can be attributed to interaction with proteins rather than nanoparticle aggregation. Total internal reflection fluorescence microscopy (TIRF), confocal microscopy studies and 3D luminescence lifetime stacks confirm the presence of bright, nonaggregated nanoparticles inside the cell. Inductively coupled plasma mass spectrometry (ICPMS) analysis further supports the presence of the nanoparticles in cells. The iridium-coated nanoparticles provide new nanoprobes for lifetime detection with dual channel monitoring. The combination of the sensitivity of the iridium signal to the cell environment together with the nanoscaffold to guide delivery offer opportunities for iridium nanoparticles for targeting and tracking in in vivo models.


Assuntos
Irídio/química , Nanopartículas Metálicas/química , Complexos de Coordenação , Ouro/química , Células HeLa , Humanos , Luminescência , Imagem Óptica , Tensoativos
5.
J Magn Reson Imaging ; 47(6): 1475-1486, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29159937

RESUMO

BACKGROUND: Pediatric retroperitoneal tumors in the renal bed are often large and heterogeneous, and their diagnosis based on conventional imaging alone is not possible. More advanced imaging methods, such as diffusion-weighted (DW) MRI and the use of intravoxel incoherent motion (IVIM), have the potential to provide additional biomarkers that could facilitate their noninvasive diagnosis. PURPOSE: To assess the use of an IVIM model for diagnosis of childhood malignant abdominal tumors and discrimination of benign from malignant lesions. STUDY TYPE: Retrospective. POPULATION: Forty-two pediatric patients with abdominal lesions (n = 32 malignant, n = 10 benign), verified by histopathology. FIELD STRENGTH/SEQUENCE: 1.5T MRI system and a DW-MRI sequence with six b-values (0, 50, 100, 150, 600, 1000 s/mm2 ). ASSESSMENT: Parameter maps of apparent diffusion coefficient (ADC), and IVIM maps of slow diffusion coefficient (D), fast diffusion coefficient (D*), and perfusion fraction (f) were computed using a segmented fitting model. Histograms were constructed for whole-tumor regions of each parameter. STATISTICAL TESTS: Comparison of histogram parameters of and their diagnostic performance was determined using Kruskal-Wallis, Mann-Whitney U, and receiver-operating characteristic (ROC) analysis. RESULTS: IVIM parameters D* and f were significantly higher in neuroblastoma compared to Wilms' tumors (P < 0.05). The ROC analysis showed that the best diagnostic performance was achieved with D* 90th percentile (area under the curve [AUC] = 0.935; P = 0.002; cutoff value = 32,376 × 10-6 mm2 /s) and f mean values (AUC = 1.00; P < 0.001; cutoff value = 14.7) in discriminating between neuroblastoma (n = 11) and Wilms' tumors (n = 8). Discrimination between tumor types was not possible with IVIM D or ADC parameters. Malignant tumors revealed significantly lower ADC, D, and higher D* values than in benign lesions (all P < 0.05). DATA CONCLUSION: IVIM perfusion parameters could distinguish between malignant childhood tumor types, providing potential imaging biomarkers for their diagnosis. LEVEL OF EVIDENCE: 4 Technical Efficacy: Stage 2 J. Magn. Reson. Imaging 2018;47:1475-1486.


Assuntos
Neoplasias Abdominais/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Pediatria/métodos , Adolescente , Algoritmos , Biomarcadores/metabolismo , Criança , Pré-Escolar , Diagnóstico por Computador , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Perfusão , Curva ROC , Estudos Retrospectivos
6.
MAGMA ; 31(2): 269-283, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-29075909

RESUMO

OBJECTIVE: This study aimed to investigate the reliability of intravoxel incoherent motion (IVIM) model derived parameters D and f and their dependence on b value distributions with a rapid three b value acquisition protocol. MATERIALS AND METHODS: Diffusion models for brain, kidney, and liver were assessed for bias, error, and reproducibility for the estimated IVIM parameters using b values 0 and 1000, and a b value between 200 and 900, at signal-to-noise ratios (SNR) 40, 55, and 80. Relative errors were used to estimate optimal b value distributions for each tissue scenario. Sixteen volunteers underwent brain DW-MRI, for which bias and coefficient of variation were determined in the grey matter. RESULTS: Bias had a large influence in the estimation of D and f for the low-perfused brain model, particularly at lower b values, with the same trends being confirmed by in vivo imaging. Significant differences were demonstrated in vivo for estimation of D (P = 0.029) and f (P < 0.001) with [300,1000] and [500,1000] distributions. The effect of bias was considerably lower for the high-perfused models. The optimal b value distributions were estimated to be brain500,1000, kidney300,1000, and liver200,1000. CONCLUSION: IVIM parameters can be estimated using a rapid DW-MRI protocol, where the optimal b value distribution depends on tissue characteristics and compromise between bias and variability.


Assuntos
Imagem de Difusão por Ressonância Magnética , Adulto , Algoritmos , Encéfalo/diagnóstico por imagem , Estudos de Coortes , Simulação por Computador , Humanos , Interpretação de Imagem Assistida por Computador/métodos , Rim/diagnóstico por imagem , Fígado/diagnóstico por imagem , Modelos Estatísticos , Movimento (Física) , Perfusão , Reprodutibilidade dos Testes , Razão Sinal-Ruído
7.
Magn Reson Med ; 77(1): 34-43, 2017 01.
Artigo em Inglês | MEDLINE | ID: mdl-26800478

RESUMO

PURPOSE: Poorly characterized macromolecular (MM) and baseline artefacts are known to reduce metabolite quantitation accuracy in 1 H MR spectroscopic imaging (MRSI). Increasing echo time (TE) and improvements in MM analysis schemes have both been proposed as strategies to improve metabolite measurement reliability. In this study, the influence of TE and two MM analysis schemes on MRSI reproducibility are investigated. METHODS: An experimentally acquired baseline was collected using an inversion recovery sequence (TI = 750 ms) and incorporated into the analysis method. Intrasubject reproducibility of MRSI scans, acquired at 3 Tesla, was assessed using metabolite coefficients of variance (COVs) for both experimentally acquired and simulated MM analysis schemes. In addition, the reproducibility of TE = 35 ms, 80 ms, and 144 ms was evaluated. RESULTS: TE = 80 ms was the most reproducible for singlet metabolites with COVs < 6% for total N-acetyl-aspartate, total creatine, and total choline; however, moderate multiplet dephasing was observed. Analysis incorporating the experimental baseline achieved higher Glu and Glx reproducibility at TE = 35 ms, and showed improvements over the simulated baseline, with higher efficacy for poorer data. CONCLUSION: Overall, TE = 80 ms yielded the most reproducible singlet metabolite estimates. However, combined use of a short TE sequence and the experimental baseline may be preferred as a compromise between accuracy, multiplet dephasing, and T2 bias on metabolite estimates. Magn Reson Med 77:34-43, 2017. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.


Assuntos
Encéfalo/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Substâncias Macromoleculares/metabolismo , Imageamento por Ressonância Magnética/métodos , Adulto , Algoritmos , Encéfalo/metabolismo , Corpo Caloso/diagnóstico por imagem , Corpo Caloso/metabolismo , Humanos , Substâncias Macromoleculares/química , Reprodutibilidade dos Testes , Adulto Jovem
8.
J Magn Reson Imaging ; 45(5): 1325-1334, 2017 05.
Artigo em Inglês | MEDLINE | ID: mdl-27545824

RESUMO

PURPOSE: To investigate the robustness of constrained and simultaneous intravoxel incoherent motion (IVIM) fitting methods and the estimated IVIM parameters (D, D* and f) for applications in brain and low-perfused tissues. MATERIALS AND METHODS: Model data simulations relevant to brain and low-perfused tumor tissues were computed to assess the accuracy, relative bias, and reproducibility (CV%) of the fitting methods in estimating the IVIM parameters. The simulations were performed at a series of signal-to-noise ratio (SNR) levels to assess the influence of noise on the fitting. RESULTS: The estimated IVIM parameters from model simulations were found significantly different (P < 0.05) using simultaneous and constrained fitting methods at low SNR. Higher accuracy and reproducibility were achieved with the constrained fitting method. Using this method, the mean error (%) for the estimated IVIM parameters at a clinically relevant SNR = 40 were D 0.35, D* 41.0 and f 4.55 for the tumor model and D 1.87, D* 2.48, and f 7.49 for the gray matter model. The most robust parameters were the IVIM-D and IVIM-f. The IVIM-D* was increasingly overestimated at low perfusion. CONCLUSION: A constrained IVIM fitting method provides more accurate and reproducible IVIM parameters in low-perfused tissue compared with simultaneous fitting. LEVEL OF EVIDENCE: 3 J. MAGN. RESON. IMAGING 2017;45:1325-1334.


Assuntos
Neoplasias Encefálicas/diagnóstico por imagem , Encéfalo/patologia , Imagem de Difusão por Ressonância Magnética/métodos , Glioma/diagnóstico por imagem , Processamento de Imagem Assistida por Computador/métodos , Algoritmos , Criança , Simulação por Computador , Meios de Contraste , Difusão , Humanos , Movimento (Física) , Distribuição Normal , Perfusão , Reprodutibilidade dos Testes , Razão Sinal-Ruído
9.
J Clin Monit Comput ; 31(5): 967-974, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-27778208

RESUMO

The Near-infrared spectroscopy (NIRS) has not been adopted as a mainstream monitoring modality in acute neurosurgical care due to concerns about its reliability and consistency. However, improvements in NIRS parameter recovery techniques are now available that may improve the quantitative accuracy of NIRS for this clinical context. Therefore, the aim of this study was to compare the abilities of a continuous-wave (CW) NIRS device with a similarly clinically viable NIRS device utilising a frequency-domain (FD) parameter recovery technique in detecting changes in cerebral tissue saturation during stepwise increases of experimentally induced hypoxia. Nine healthy individuals (6M/3F) underwent a dynamic end-tidal forced manipulation of their expiratory gases to induce a stepwise induced hypoxia. The minimum end-tidal oxygen partial pressure (EtO2) achieved was 40 mm Hg. Simultaneous neurological and extra-cranial tissue NIRS reading were obtained during this protocol by both tested devices. Both devices detected significant changes in cerebral tissue saturation during the induction of hypoxia (CW 9.8 ± 2.3 %; FD 7.0 ± 3.4 %; Wilcoxon signed rank test P < 0.01 for both devices). No significant difference was observed between the saturation changes observed by either device (P = 0.625). An observably greater degree of noise was noticed in parameters recovered by the FD device, and both demonstrated equally variable baseline readings (Coefficient of variance 8.4 and 9.7 % for the CW and FD devices, respectively) between individuals tested. No advantageous difference was observed in parameters recovered from the FD device compared with those detected by CW.


Assuntos
Encéfalo/diagnóstico por imagem , Hipóxia , Consumo de Oxigênio , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Computadores , Feminino , Voluntários Saudáveis , Humanos , Masculino , Oxigênio , Pressão Parcial , Estudos Prospectivos , Reprodutibilidade dos Testes , Processamento de Sinais Assistido por Computador
10.
J Adolesc Health ; 75(1): 133-139, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38597839

RESUMO

PURPOSE: In the current world, adolescents are less likely to turn to physical activity games and often prefer to spend more time in the technological and digital world and have fun with digital games. This study aimed to explore reasons for preferring digital games to physical activity games in adolescents. METHODS: Twenty-one adolescents participated in this qualitative study. The participants' age ranged from 11 to 19 who participated in semistructured interviews. The recorded interviews underwent thematic analysis to identify overall themes. RESULTS: Five overall themes were identified from the interviews regarding reasons for preferring digital games over physical activity games. Identified themes included game characteristics, game space, game outcomes, peer pressure, and accessibility. DISCUSSION: The findings of this research contribute to design adolescent-centered interventions that sustain/increase adolescents' interest in physical activity games and protect them from excessive/harmful use of digital games.


Assuntos
Comportamento do Adolescente , Exercício Físico , Pesquisa Qualitativa , Jogos de Vídeo , Humanos , Adolescente , Feminino , Masculino , Exercício Físico/psicologia , Comportamento do Adolescente/psicologia , Criança , Adulto Jovem , Entrevistas como Assunto
11.
Phys Med Biol ; 69(2)2024 Jan 22.
Artigo em Inglês | MEDLINE | ID: mdl-38181420

RESUMO

Objective. Small-field dosimetry is an ongoing challenge in radiotherapy quality assurance (QA) especially for radiosurgery systems such as CyberKnifeTM. The objective of this work is to demonstrate the use of a plastic scintillator imaged with a commercial camera to measure the output factor of a CyberKnife system. The output factor describes the dose on the central axis as a function of collimator size, and is a fundamental part of CyberKnife QA and integral to the data used in the treatment planning system.Approach. A self-contained device consisting of a solid plastic scintillator and a camera was build in a portable Pelicase. Photographs were analysed using classical methods and with convolutional neural networks (CNN) to predict beam parameters which were then compared to measurements.Main results. Initial results using classical image processing to determine standard QA parameters such as percentage depth dose (PDD) were unsuccessful, with 34% of points failing to meet the Gamma criterion (which measures the distance between corresponding points and the relative difference in dose) of 2 mm/2%. However, when images were processed using a CNN trained on simulated data and a green scintillator sheet, 92% of PDD curves agreed with measurements with a microdiamond detector to within 2 mm/2% and 78% to 1%/1 mm. The mean difference between the output factors measured using this system and a microdiamond detector was 1.1%. Confidence in the results was enhanced by using the algorithm to predict the known collimator sizes from the photographs which it was able to do with an accuracy of less than 1 mm.Significance. With refinement, a full output factor curve could be measured in less than an hour, offering a new approach for rapid, convenient small-field dosimetry.


Assuntos
Aprendizado Profundo , Radiocirurgia , Radiometria/métodos , Radiocirurgia/métodos , Algoritmos , Redes Neurais de Computação
12.
J Biomed Opt ; 29(7): 076004, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-39035576

RESUMO

Significance: Frequency-domain diffuse optical tomography (FD-DOT) could enhance clinical breast tumor characterization. However, conventional diffuse optical tomography (DOT) image reconstruction algorithms require case-by-case expert tuning and are too computationally intensive to provide feedback during a scan. Deep learning (DL) algorithms front-load computational and tuning costs, enabling high-speed, high-fidelity FD-DOT. Aim: We aim to demonstrate a simultaneous reconstruction of three-dimensional absorption and reduced scattering coefficients using DL-FD-DOT, with a view toward real-time imaging with a handheld probe. Approach: A DL model was trained to solve the DOT inverse problem using a realistically simulated FD-DOT dataset emulating a handheld probe for human breast imaging and tested using both synthetic and experimental data. Results: Over a test set of 300 simulated tissue phantoms for absorption and scattering reconstructions, the DL-DOT model reduced the root mean square error by 12 % ± 40 % and 23 % ± 40 % , increased the spatial similarity by 17 % ± 17 % and 9 % ± 15 % , increased the anomaly contrast accuracy by 9 % ± 9 % ( µ a ), and reduced the crosstalk by 5 % ± 18 % and 7 % ± 11 % , respectively, compared with model-based tomography. The average reconstruction time was reduced from 3.8 min to 0.02 s for a single reconstruction. The model was successfully verified using two tumor-emulating optical phantoms. Conclusions: There is clinical potential for real-time functional imaging of human breast tissue using DL and FD-DOT.


Assuntos
Algoritmos , Neoplasias da Mama , Aprendizado Profundo , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Tomografia Óptica , Tomografia Óptica/métodos , Tomografia Óptica/instrumentação , Humanos , Processamento de Imagem Assistida por Computador/métodos , Neoplasias da Mama/diagnóstico por imagem , Mama/diagnóstico por imagem , Feminino , Imageamento Tridimensional/métodos
13.
Opt Express ; 21(6): 7222-39, 2013 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-23546107

RESUMO

Knowledge of the surface geometry of an imaging subject is important in many applications. This information can be obtained via a number of different techniques, including time of flight imaging, photogrammetry, and fringe projection profilometry. Existing systems may have restrictions on instrument geometry, require expensive optics, or require moving parts in order to image the full surface of the subject. An inexpensive generalised fringe projection profilometry system is proposed that can account for arbitrarily placed components and use mirrors to expand the field of view. It simultaneously acquires multiple views of an imaging subject, producing a cloud of points that lie on its surface, which can then be processed to form a three dimensional model. A prototype of this system was integrated into an existing Diffuse Optical Tomography and Bioluminescence Tomography small animal imaging system and used to image objects including a mouse-shaped plastic phantom, a mouse cadaver, and a coin. A surface mesh generated from surface capture data of the mouse-shaped plastic phantom was compared with ideal surface points provided by the phantom manufacturer, and 50% of points were found to lie within 0.1mm of the surface mesh, 82% of points were found to lie within 0.2mm of the surface mesh, and 96% of points were found to lie within 0.4mm of the surface mesh.


Assuntos
Aumento da Imagem/instrumentação , Lentes , Iluminação/instrumentação , Modelos Teóricos , Tomografia de Coerência Óptica/instrumentação , Animais , Cadáver , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Luz , Camundongos
14.
J Opt Soc Am A Opt Image Sci Vis ; 30(12): 2572-84, 2013 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-24323019

RESUMO

A novel method is presented for accurately reconstructing a spatially resolved map of diffuse light flux on a surface using images of the surface and a model of the imaging system. This is achieved by applying a model-based reconstruction algorithm with an existing forward model of light propagation through free space that accounts for the effects of perspective, focus, and imaging geometry. It is shown that flux can be mapped reliably and quantitatively accurately with very low error, <3% with modest signal-to-noise ratio. Simulation shows that the method is generalizable to the case in which mirrors are used in the system and therefore multiple views can be combined in reconstruction. Validation experiments show that physical diffuse phantom surface fluxes can also be reconstructed accurately with variability <3% for a range of object positions, variable states of focus, and different orientations. The method provides a new way of making quantitatively accurate noncontact measurements of the amount of light leaving a diffusive medium, such as a small animal containing fluorescent or bioluminescent markers, that is independent of the imaging system configuration and surface position.


Assuntos
Nefelometria e Turbidimetria/métodos , Algoritmos , Animais , Calibragem , Simulação por Computador , Difusão , Desenho de Equipamento , Corantes Fluorescentes/química , Humanos , Processamento de Imagem Assistida por Computador , Luz , Luminescência , Imagens de Fantasmas , Reprodutibilidade dos Testes , Razão Sinal-Ruído , Propriedades de Superfície
15.
Plant Methods ; 19(1): 25, 2023 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-36915142

RESUMO

BACKGROUND: Selection is one of the essential skills whereby breeders reduce the population size and increase the chance of success. Various selection methods with special applications have been developed. Superior genotypes are assessed according to interesting traits, including univariate, multivariate, phenotypic, genotypic, etc. METHODS: Mathematical calculation of the traits' importance based on the genetic makeup of investigated population (average degree of dominance/additive involved in the action of genes) and arbitrary genetic parameters is functional. In this paper, a general model for multivariate selection has been presented whereby the selection can be made for (a) more than one interesting trait, (b) the trait(s) with complex inheritance, (c) finding superior genotypes from among a large-scale population, (d) finding superior genotypes in segregating generations and (f) finding tolerant genotypes to stresses. This model is developed based on biometric concepts in four steps. MATLAB script is provided for the model, and users can easily apply that to identify the most suitable genotypes after data collection according to the breeding purposes. RESULTS: The main features of this model are simplicity, precision, repeatability, and speed (improving several traits simultaneously). All the steps and the analysis of the results are explained step by step in a case study.

16.
AoB Plants ; 15(6): plad037, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38090390

RESUMO

The tomato (Solanum lycopersicum L.) is an annual vegetable cultivated all over the world. It faces biotic and abiotic stresses, such as salinity, in arid and semiarid regions. Investigating the relationship between physiological and economic traits, such as fruit yield, under stress conditions is necessary to identify tolerant genotypes. This study was conducted to identify tolerant tomato families according to the relationship between several important physiological, morphological and phenological traits. Twenty S3 families were cultivated in a factorial experiment (factor1: families and factor2: normal conditions and salinity stress) based on a randomized complete block design with three replications in 2019. Twenty physiological, agronomic and fruit-quality-related traits were investigated. Analysis of variance was used to prove the existing effective genetic diversity. Genetic diversity and the relationships between traits were graphically shown using heatmap clustering. Finally, genetic parameters, such as Pearson's correlation, trait stability index and heritability were used to calculate the mathematical value of families using the Modified Analytical Hierarchy Process. Families exhibited different behaviours under normal and stress conditions. The tolerant families responded physiologically to the salt stress. Therefore, they reduced both cell membrane degradation and photosynthesis disruption by increasing proline, lycopene, carotenoid and sugar content. Therefore, fewer reductions in morphological traits were observed in these families. The most important traits based on the selection strategy were lycopene content, K+/Na+ ratio, days to flowering and biological yield. In addition, three families, H4/T/30/1, H1/T/12/5 and H1/T/47/4, were selected as the most suitable alternatives to construct the breeding population of the next generation.

17.
IEEE Open J Eng Med Biol ; 4: 85-95, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37228451

RESUMO

An intuitive and generalisable approach to spatial-temporal feature extraction for high-density (HD) functional Near-Infrared Spectroscopy (fNIRS) brain-computer interface (BCI) is proposed, demonstrated here using Frequency-Domain (FD) fNIRS for motor-task classification. Enabled by the HD probe design, layered topographical maps of Oxy/deOxy Haemoglobin changes are used to train a 3D convolutional neural network (CNN), enabling simultaneous extraction of spatial and temporal features. The proposed spatial-temporal CNN is shown to effectively exploit the spatial relationships in HD fNIRS measurements to improve the classification of the functional haemodynamic response, achieving an average F1 score of 0.69 across seven subjects in a mixed subjects training scheme, and improving subject-independent classification as compared to a standard temporal CNN.

18.
Biomed Opt Express ; 14(12): 6592-6606, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-38420302

RESUMO

Diffuse Raman spectroscopy (DRS) allows subsurface molecular analysis of optically turbid samples. Numerical modeling of light propagation was used as a method for improving the design of an DRS instrument to maximize the signal to noise ratio (SNR) while ensuring safe laser exposure parameters required for in-vivo measurements. Experimental validation of the model was performed on both phantom samples and disks implanted postmortem to mimic the typical response to foreign bodies (formation of a fibrotic capsule around an implant). A reduction of laser exposure of over 1500-fold was achieved over previous studies whilst maintaining the same Raman collection rates and reaching the safe power density of 3 mW/mm2. The validation of this approach in a subcutaneous implant in a mouse cadaver showed a further improvement of 1.5-fold SNR, with a thickness limit of detection for the fibrotic layer of 23 µm, under the same acquisition times. In the animal body, a thickness limit of detection of 16 µm was achieved. These results demonstrate the feasibility of numerical model-based optimization for DRS, and that the technique can be improved sufficiently to be used for in-vivo measurement of collagenous capsule formation as a result of the foreign body response in murine models.

19.
Med Phys ; 50(10): 6433-6453, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37633836

RESUMO

BACKGROUND: Widely used Cone-beam computed tomography (CBCT)-guided irradiators have limitations in localizing soft tissue targets growing in a low-contrast environment. This hinders small animal irradiators achieving precise focal irradiation. PURPOSE: To advance image-guidance for soft tissue targeting, we developed a commercial-grade bioluminescence tomography-guided system (BLT, MuriGlo) for pre-clinical radiation research. We characterized the system performance and demonstrated its capability in target localization. We expect this study can provide a comprehensive guideline for the community in utilizing the BLT system for radiation studies. METHODS: MuriGlo consists of four mirrors, filters, lens, and charge-coupled device (CCD) camera, enabling a compact imaging platform and multi-projection and multi-spectral BLT. A newly developed mouse bed allows animals imaged in MuriGlo and transferred to a small animal radiation research platform (SARRP) for CBCT imaging and BLT-guided irradiation. Methods and tools were developed to evaluate the CCD response linearity, minimal detectable signal, focusing, spatial resolution, distortion, and uniformity. A transparent polycarbonate plate covering the middle of the mouse bed was used to support and image animals from underneath the bed. We investigated its effect on 2D Bioluminescence images and 3D BLT reconstruction accuracy, and studied its dosimetric impact along with the rest of mouse bed. A method based on pinhole camera model was developed to map multi-projection bioluminescence images to the object surface generated from CBCT image. The mapped bioluminescence images were used as the input data for the optical reconstruction. To account for free space light propagation from object surface to optical detector, a spectral derivative (SD) method was implemented for BLT reconstruction. We assessed the use of the SD data (ratio imaging of adjacent wavelength) in mitigating out of focusing and non-uniformity seen in the images. A mouse phantom was used to validate the data mapping. The phantom and an in vivo glioblastoma model were utilized to demonstrate the accuracy of the BLT target localization. RESULTS: The CCD response shows good linearity with < 0.6% residual from a linear fit. The minimal detectable level is 972 counts for 10 × 10 binning. The focal plane position is within the range of 13-18 mm above the mouse bed. The spatial resolution of 2D optical imaging is < 0.3 mm at Rayleigh criterion. Within the region of interest, the image uniformity is within 5% variation, and image shift due to distortion is within 0.3 mm. The transparent plate caused < 6% light attenuation. The use of the SD imaging data can effectively mitigate out of focusing, image non-uniformity, and the plate attenuation, to support accurate multi-spectral BLT reconstruction. There is < 0.5% attenuation on dose delivery caused by the bed. The accuracy of data mapping from the 2D bioluminescence images to CBCT image is within 0.7 mm. Our phantom test shows the BLT system can localize a bioluminescent target within 1 mm with an optimal threshold and only 0.2 mm deviation was observed for the case with and without a transparent plate. The same localization accuracy can be maintained for the in vivo GBM model. CONCLUSIONS: This work is the first systematic study in characterizing the commercial BLT-guided system. The information and methods developed will be useful for the community to utilize the imaging system for image-guided radiation research.

20.
Physiol Meas ; 44(12)2023 Dec 26.
Artigo em Inglês | MEDLINE | ID: mdl-38061053

RESUMO

Objective.In this paper, we present a detailedin vivocharacterization of the optical and hemodynamic properties of the human sternocleidomastoid muscle (SCM), obtained through ultrasound-guided near-infrared time-domain and diffuse correlation spectroscopies.Approach.A total of sixty-five subjects (forty-nine females, sixteen males) among healthy volunteers and thyroid nodule patients have been recruited for the study. Their SCM hemodynamic (oxy-, deoxy- and total hemoglobin concentrations, blood flow, blood oxygen saturation and metabolic rate of oxygen extraction) and optical properties (wavelength dependent absorption and reduced scattering coefficients) have been measured by the use of a novel hybrid device combining in a single unit time-domain near-infrared spectroscopy, diffuse correlation spectroscopy and simultaneous ultrasound imaging.Main results.We provide detailed tables of the results related to SCM baseline (i.e. muscle at rest) properties, and reveal significant differences on the measured parameters due to variables such as side of the neck, sex, age, body mass index, depth and thickness of the muscle, allowing future clinical studies to take into account such dependencies.Significance.The non-invasive monitoring of the hemodynamics and metabolism of the sternocleidomastoid muscle during respiration became a topic of increased interest partially due to the increased use of mechanical ventilation during the COVID-19 pandemic. Near-infrared diffuse optical spectroscopies were proposed as potential practical monitors of increased recruitment of SCM during respiratory distress. They can provide clinically relevant information on the degree of the patient's respiratory effort that is needed to maintain an optimal minute ventilation, with potential clinical application ranging from evaluating chronic pulmonary diseases to more acute settings, such as acute respiratory failure, or to determine the readiness to wean from invasive mechanical ventilation.


Assuntos
Músculo Esquelético , Espectroscopia de Luz Próxima ao Infravermelho , Masculino , Feminino , Humanos , Espectroscopia de Luz Próxima ao Infravermelho/métodos , Músculo Esquelético/fisiologia , Pandemias , Oxigênio/metabolismo , Hemodinâmica , Ultrassonografia , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA