Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 252
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(8): 1601-1613, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38887842

RESUMO

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.


Assuntos
Apêndice Atrial , Ecocardiografia Quadridimensional , Ecocardiografia Transesofagiana , Fluxo de Trabalho , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Valor Preditivo dos Testes , Cateterismo Cardíaco/instrumentação , Ultrassonografia de Intervenção , Masculino
2.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073051

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Assuntos
Hospitalização , Alta do Paciente , Humanos , Remoção de Dispositivo , Estudos de Viabilidade , Estudos Retrospectivos , Resultado do Tratamento
3.
Artigo em Inglês | MEDLINE | ID: mdl-39135364

RESUMO

INTRODUCTION: Thermal atrial fibrillation (AF) ablation exerts an additive treatment effect on the cardiac autonomic nervous system (CANS). This effect is mainly reported during ablation of the right superior pulmonary vein (RSPV), modulating the right anterior ganglionated plexus (RAGP), which contains parasympathetic innervation to the sinoatrial node in the epicardial fat pad between RSPV and superior vena cava (SVC). However, a variable response to neuromodulation after ablation is observed, with little to no effect in some patients. Our objective was to assess clinical and anatomic predictors of thermal ablation-induced CANS changes, as assessed via variations in heart rate (HR) postablation. METHODS: Consecutive paroxysmal AF patients undergoing first-time PV isolation by the cryoballoon (CB) or radiofrequency balloon (RFB) within a 12-month time frame and with preprocedural cardiac computed tomography (CT), were evaluated. Preablation and 24-h postablation electrocardiograms in sinus rhythm were collected and analyzed to assess HR. Anatomic evaluation by CT included the measurement of the shortest distance between the SVC and RSPV ostium (RSPV-SVC distance). RESULTS: A total of 97 patients (CB, n = 50 vs. RFB, n = 47) were included, with similar baseline characteristics between both groups. A significant HR increase postablation (ΔHR ≥ 15 bpm) occurred in a total of 37 patients (38.1%), without difference in number of patients between both thermal ablation technologies (CB, 19 [51%]), RFB, 18 [49%]). Independent predictors for increased HR were RSPV-SVC distance (odds ratio [OR]: 0.49, CI: 0.34-0.71, p value < .001), and age (OR: 0.94, CI: 0.89-0.98, p value = .003). CONCLUSIONS: Thermal balloon-based PV isolation influences the CANS through its effect on the RAGP, especially in younger patients and patients with shorter RSPV-SVC distance.

4.
Catheter Cardiovasc Interv ; 104(2): 220-226, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-38959377

RESUMO

BACKGROUND: The treatment of resistant coronary lesions (RCL) is a great challenge for interventional cardiologists. The excimer laser coronary atherectomy (ELCA) is a plaque modification tool based on a main mechanism of photomechanical effect leading to mechanical disruption of the plaque. Contrast dye injection during laser delivery has demonstrated to enhance its power. AIM: To evaluate the effectiveness and safety of the contrast-enhanced ELCA by a stepwise approach in the treatment of RCLs. METHODS: We retrospectively examined consecutive patients undergoing contrast-enhanced ELCA-assisted PCI between 2018 and 2021 at two Italian sites. RCLs were defined as novo or in-stent undilatable/uncrossable with conventional balloons (SC/NC balloon). The primary endpoint was ELCA technical success defined as the laser catheter crossing the entire length of the target lesion established by angiographic evidence of the catheter tip in the artery distal to the stenosis. RESULTS: We enrolled 114 patients who underwent contrast-enhanced ELCA-assisted PCI: 58% of the patients had acute coronary syndrome while the left anterior descending artery was the target vessel in 42.1% of cases. The target lesion was most commonly in-stent (56.2%). The 0.9 mm ELCA catheter tip was employed in 89.5% of cases. The most used frequency/fluency profile was 70/70 (39.5%). The use of contrast-enhanced ELCA was associated with high technical, procedural, and clinical success rates (97.4%, 93.7%, and 90.1%, respectively). CONCLUSIONS: The contrast-enhanced ELCA seems to be a safe and effective treatment option for the management of both de novo and in-stent-resistant coronary lesions.


Assuntos
Aterectomia Coronária , Meios de Contraste , Doença da Artéria Coronariana , Lasers de Excimer , Humanos , Estudos Retrospectivos , Masculino , Feminino , Idoso , Lasers de Excimer/uso terapêutico , Aterectomia Coronária/efeitos adversos , Resultado do Tratamento , Pessoa de Meia-Idade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Meios de Contraste/administração & dosagem , Itália , Angiografia Coronária , Valor Preditivo dos Testes , Fatores de Tempo , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/efeitos adversos , Stents , Fatores de Risco
5.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39150065

RESUMO

AIMS: Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter-tissue contact impact lesion formation during PFA. METHODS AND RESULTS: A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). CONCLUSION: Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.


Assuntos
Cateteres Cardíacos , Ablação por Cateter , Desenho de Equipamento , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Animais , Suínos , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Modelos Animais , Sus scrofa , Fatores de Tempo
6.
Europace ; 2024 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-39351961

RESUMO

BACKGROUND AND AIMS: Rhythm control of non-paroxysmal atrial fibrillation (AF) is significantly more challenging, as a result of arrhythmia perpetuation promoting atrial substrate changes and AF maintenance. We describe a tailored ablation strategy targeting multiple left atrial (LA) sites via a pentaspline pulsed field ablation (PFA) catheter in persistent AF sustained beyond 6 months (PerAF>6m) and long-standing persistent AF (LSPAF). METHODS: The ablation protocol included the following stages: pulmonary vein antral and posterior wall isolation plus anterior roof line ablation (Stage 1); electrogram-guided substrate ablation (Stage 2); atrial tachyarrhythmia regionalization and ablation (Stage 3). RESULTS: Seventy-two [age:68±10years, 61.1%males; AF history: 25 (18-45) months] patients with PerAF>6m (52.8%) and LSPAF (47.2%) underwent their first PFA via the FarapulseTM system. LA substrate ablation (Stage 1 and 2) led to AF termination in 95.8% of patients. AF organized into a left-sided atrial flutter (AFlu) in 46 (74.2%) patients. The PFA catheter was used to identify LA sites showing diastolic, low-voltage electrograms and entrainment from its splines was performed to confirm the pacing site was inside the AFlu circuit. Left AFlu termination was achieved in all cases via PFA delivery. Total procedural and LA dwell times were 112±25min and 59±22 min, respectively. Major complications occurred in 2 (2.8%) patients. Single-procedure success rate was 74.6% after 14.9±2.7 months of follow-up; AF-free survival was 89.2%. CONCLUSIONS: In our cohort, PFA-based AF substrate ablation led to AF termination in 95.8% of cases. Very favorable clinical outcomes were observed during >1year of follow-up.

7.
Cardiology ; : 1-8, 2024 Jul 22.
Artigo em Inglês | MEDLINE | ID: mdl-38986462

RESUMO

INTRODUCTION: Patients undergoing left atrial appendage occlusion (LAAO) are at increased risk for bleeding or thromboembolic events. Concurrently, biomarkers are of growing importance in risk stratification for atrial fibrillation patients. We aimed to evaluate the association of hematological markers and clinical characteristics with the occurrence of thromboembolic and bleeding events following LAAO. METHODS: Seven implanting centers retrospectively gathered data on hematological markers (i.e., platelet count [PC], mean platelet volume [MPV], and fibrinogen) prior to LAAO. Prespecified thromboembolic and major bleeding outcomes were collected and the association with pre-procedural hematological markers and clinical characteristics was evaluated using Cox regression analysis. RESULTS: In total, 1,315 patients were included (74 ± 9 years, 36% female, CHA2DS2-VASc 4.3 ± 1.5, HAS-BLED 3.3 ± 1.1). Over a total follow-up duration of 2,682 patient years, 77 thromboembolic events and 107 major bleeding events occurred after LAAO. Baseline PC was the only biomarker showing a signal for a relation to thromboembolic events (HR 1.18, 95% CI: 1.00-1.39) per 50*109 increment, p = 0.056). Thrombotic event rates, including device-related thrombus, increased within higher PC quartiles. Thromboembolism was associated with age (HR 1.05, 95% CI: 1.00-1.10, per year increase) and prior thromboembolism (HR 2.08, 95% CI: 1.07-4.03), but with none of the biomarkers in multivariate analysis. No association of any of the hematological markers with major bleeding was observed. Major bleeding following LAAO was associated with prior major bleeding (HR 5.27, 95% CI: 2.71-10.22), renal disease (HR 1.93, 95% CI: 1.17-3.18), and discharge on dual antiplatelet therapy (DAPT) (HR 1.71, 95% CI: 1.05-2.77). CONCLUSION: Most thrombotic events occurred in the highest PC quartile, but no association of any of the hematological markers with thromboembolism or major bleeding was observed in our analysis. In multivariate analysis, older age and prior thromboembolism were associated with thromboembolism. Prior major bleeding, renal disease and discharge on DAPT were multivariate predictors of major bleeding after LAAO.

8.
Eur Heart J ; 44(35): 3327-3335, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37387689

RESUMO

AIMS: Management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains complex. The Antwerp score, based on four parameters [QRS >120 ms (2 points), known aetiology (2 points), paroxysmal AF (1 point), severe atrial dilation (1 point)] adequately estimated the probability of left ventricular ejection fraction (LVEF) recovery after AF ablation in a single-centre cohort. The present study aims to externally validate this prediction model in a large European multi-centre cohort. METHODS AND RESULTS: A total of 605 patients (61.1 ± 9.4 years, 23.8% females, 79.8% with persistent AF) with HF and impaired LVEF (<50%) undergoing AF ablation in 8 European centres were retrospectively identified. According to the LVEF changes at 12-month echocardiography, 427 (70%) patients fulfilled the '2021 Universal Definition of HF' criteria for LVEF recovery and were defined as 'responders'. External validation of the score yielded good discrimination and calibration {area under the curve 0.86 [95% confidence interval (CI) 0.82-0.89], P < .001; Hosmer-Lemeshow P = .29}. Patients with a score < 2 had a 93% probability of LVEF recovery as opposed to only 24% in patients with a score > 3. Responders experienced more often positive ventricular remodelling [odds ratio (OR) 8.91, 95% CI 4.45-17.84, P < .001], fewer HF hospitalizations (OR 0.09, 95% CI 0.05-0.18, P < .001) and lower mortality (OR 0.11, 95% CI 0.04-0.31, P < .001). CONCLUSION: In this multi-centre study, a simple four-parameter score predicted LVEF recovery after AF ablation in patients with HF and discriminated clinical outcomes. These findings support the use of the Antwerp score to standardize shared decision-making regarding AF ablation referral in future clinical studies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Feminino , Humanos , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
9.
J Cardiovasc Electrophysiol ; 34(11): 2393-2397, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37792572

RESUMO

INTRODUCTION: Pulmonary vein isolation (PVI) with thermal energy is characterized by concomitant ablation of the surrounding ganglionated plexi (GP). Pulsed-field ablation (PFA) selectively targets the myocardium and seems associated with only negligible effects on the autonomic nervous system (ANS). However, little is known about the dynamic effects of PFA on the GP immediately after PVI. This study sought to investigate the degree and acute vagal modulation induced by the FarapulseTM PFA system during PVI compared with single-shot thermal ablation. METHODS: A total of 76 patients underwent first-time PVI with either FarapulseTM PFA (PFA group, n = 40) or cryoballoon ablation (thermal ablation group, n = 36) for paroxysmal atrial fibrillation (AF). The effect on the ANS in the two groups was assessed before and after PVI with extracardiac vagal stimulation (ECVS). To capture any transient effects of PFA on the ANS, in a subgroup of PFA patients ECVS was repeated at three predefined timepoints: (1) before PVI (T0); (2) immediately after PVI (T1); and (3) 10 min after the last energy application (T2). RESULTS: Despite similar baseline values, the vagal response induced by ECVS after PVI almost disappeared in the thermal ablation group but persisted in the PFA group (thermal group: 840 [706-1090] ms, p < .001 compared to baseline; PFA group: 11 466 [8720-12 293] ms, p = .70 compared to baseline). Intraprocedural vagal reactions (defined as RR increase >50%, transitory asystole, or atrioventricular block) occurred more frequently with PFA than thermal ablation (70% vs. 28%, p = .001). Moreover, heart rate 24 h post-PVI increased more with thermal ablation than with PFA (16.5 ± 9.0 vs. 2.6 ± 6.1 beats/min, p < .001). In the subgroup of PFA patients undergoing repeated ANS modulation assessment (n = 11), ECVS demonstrated that PFA determined a significant acute suppression of the vagal response immediately after PVI (p < .001 compared to baseline), which recovered almost completely within 10 min. CONCLUSION: PVI with the FarapulseTM PFA system is associated with only transitory and short-lasting vagal effects on the ANS which recover almost completely within a few minutes after ablation. The impact of this phenomenon on AF outcome needs to be further investigated.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Sistema Nervoso Autônomo/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Nervo Vago/cirurgia , Frequência Cardíaca , Ablação por Cateter/efeitos adversos , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 34(10): 2136-2144, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36069138

RESUMO

This article reviews the latest available data in regard to the diagnosis, management, and intervention of both central and peri-device leaks that arise after left atrial appendage closure (LAAC). The aim of this article is to have a better understanding of both addressing leaks arising after LAAC, and which interventions and closure methods are best served for each type of residual leak based on etiology, size, and operator experience.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos
11.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493490

RESUMO

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Assuntos
Miocardite , Sarcoidose , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Gadolínio , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética/efeitos adversos , Miocardite/complicações , Prognóstico , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda
12.
J Cardiovasc Electrophysiol ; 34(12): 2527-2534, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37746923

RESUMO

INTRODUCTION: Earlier studies have shown a clear association between severity of human immunodeficiency virus (HIV) infection and incident atrial fibrillation (AF). We present the long-term outcome of catheter ablation (CA) and electrophysiological characteristics in HIV+ AF patients. METHODS: This study evaluated 1438 consecutive AF patients [31 (2.15%) with HIV and 1407 (97.8%) without HIV diagnosis] undergoing their first CA at our center. A total of 31 HIV patients and 31 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model. During first procedure, all received isolation of pulmonary vein (PV) + posterior wall and superior vena cava. Non-PV triggers, defined as ectopic triggers originating from sites other than PVs, were identified at the redo ablation with high-dose isoproterenol challenge. RESULTS: Clinical characteristics were not different between the groups. When compared to the control, by the end of 5 years after the first procedure, recurrence was significantly greater in HIV group [100% vs. 54%, p < .001]. Among patients that underwent redo ablation non-PV triggers were higher in HIV group [93.5% vs. 54%, p < .001], and most frequently originated from the coronary sinus [67.7% vs. 45.2%, p < .001] and left atrial appendage [41.9% vs. 25.8%, p < .001]. After focal ablation of non-PV trigger, no difference in arrhythmia recurrence between two groups [80.6% vs. 87.1%, p = .753] at 1-year follow up was found. CONCLUSION: Our findings suggest that non-PV triggers are highly prevalent in HIV+ AF patients resulting in higher rate of the mid- and long-term arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Infecções por HIV , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Infecções por HIV/complicações , Infecções por HIV/diagnóstico , Veia Cava Superior , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
13.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378783

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Prevalência , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos
14.
Catheter Cardiovasc Interv ; 101(6): 1144-1153, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36924020

RESUMO

AIMS: To compare outcomes of patients who underwent left atrial appendage occlusion (LAAO) for nonvalvular atrial fibrillation (NVAF) and contraindication to anticoagulants due to history of either gastrointestinal (GI) or intracranial (IC) bleeding. METHODS: Patients with NVAF that underwent LAAO for GI or IC bleeding from seven centers were included in this observational study. Baseline characteristics, procedural features, and follow-up data were collected, and compared between the two groups. The primary outcomes were incidence of ischemic and hemorrhagic events at 12-month. RESULTS: Six hundred twenty-eight patients were included, 57% with previous GI-bleeding, and 43% with previous IC-bleeding. Median CHA 2 DS 2-VASc score was 4 (interquartile range [IQRs]: 3-5) for both GI-bleeding and IC-bleeding patients, while GI-bleeding patients had a higher HAS-BLED score (4 [IQRs: 3-4] vs. 3 [IQRs]: 2-3]; p = 0.001). At 12-month follow-up, relative risk reduction for stroke was similar between the two groups. The GI-bleeding group had more hemorrhagic events compared to IC-bleeding group (any bleeding 8.4% vs. 3.2%; p = 0.012; major bleeding BARC 3-5: 4.3% vs. 1.8; p = 0.010). At multivariate analysis history of GI bleeding was an independent predictor of hemorrhagic events (adjusted HR: 2.39, 95% confidence interval: 1.02-5.63; p = 0.047). CONCLUSIONS: Outcomes after LAAO may be affected by the different indications for the procedure. In our study, GI-bleeding and IC-bleeding as indication to LAAO differ in their baseline characteristics. LAAO confirms its efficacy in ischemic risk reduction in both groups, while GI bleeding seems to be an independent predictor of bleeding recurrence at 12 months behind the antithrombotic regimen.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/prevenção & controle , Hemorragias Intracranianas/etiologia , Sistema de Registros , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Lógica
15.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37671682

RESUMO

AIMS: Cryoballoon (CB) ablation is the mainstay of single-shot pulmonary vein isolation (PVI). A radiofrequency balloon (RFB) catheter has recently emerged as an alternative. However, these two technologies have not been compared. This study aims to evaluate the freedom from atrial tachyarrhythmias (ATas) at 1 year: procedural characteristics, efficacy, and safety of the novel RFB compared with CB for PVI in patients with paroxysmal atrial fibrillation (AF). METHODS AND RESULTS: This prospective multi-centre study included consecutive patients with symptomatic drug-resistant paroxysmal AF who underwent PVI with RFB or CB between July 2021 and January 2022 from three European centres. A total of 375 consecutive patients were included, 125 in the RFB group and 250 in the CB. Both groups had comparable clinical characteristics. At 12.33 ± 4.91 months, ATas-free rates were 83.20% and 82.00% in the RFB and CB groups, respectively (P > 0.05). Compared with the CB group, the RFB group showed a shorter procedure time [59.91 (45.80-77.12) vs. 77.0 (35.13-122.71) min (P < 0.001)], dwell time [19.59 (14.41-30.24) vs. 27.03 (17.11-57.21) min (P = 0.04)], time to isolation, and thermal energy delivery in all pulmonary veins (P < 0.001). First-pass isolation was comparable. No major complications occurred in either group, with no stroke, atrio-oesophageal fistula, or permanent phrenic nerve injury. Transient phrenic nerve palsy occurred more frequently with CB than RFB (7.20% vs. 3.20%; P = 0.02). Oesophageal temperature rise occurred in 21 (16.8%) patients in the RFB group, and gastroscopy showed erythema in two of them with complete recovery after 30 days. CONCLUSIONS: The RFB appears to have a safety and efficacy profile similar to that of the CB for PVI. Shorter procedural times appear to be driven by shorter left atrial dwell and thermal delivery times.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Fístula Esofágica , Veias Pulmonares , Humanos , Estudos Prospectivos
16.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37477946

RESUMO

AIMS: Intracardiac echocardiography (ICE) is a useful but operator-dependent tool for left atrial (LA) anatomical rendering during atrial fibrillation (AF) ablation. The CARTOSOUND FAM Module, a new deep learning (DL) imaging algorithm, has the potential to overcome this limitation. This study aims to evaluate feasibility of the algorithm compared to cardiac computed tomography (CT) in patients undergoing AF ablation. METHODS AND RESULTS: In 28 patients undergoing AF ablation, baseline patient information was recorded, and three-dimensional (3D) shells of LA body and anatomical structures [LA appendage/left superior pulmonary vein/left inferior pulmonary vein/right superior pulmonary vein/right inferior pulmonary vein (RIPV)] were reconstructed using the DL algorithm. The selected ultrasound frames were gated to end-expiration and max LA volume. Ostial diameters of these structures and carina-to-carina distance between left and right pulmonary veins were measured and compared with CT measurements. Anatomical accuracy of the DL algorithm was evaluated by three independent electrophysiologists using a three-anchor scale for LA anatomical structures and a five-anchor scale for LA body. Ablation-related characteristics were summarized. The algorithm generated 3D reconstruction of LA anatomies, and two-dimensional contours overlaid on ultrasound input frames. Average calculation time for LA reconstruction was 65 s. Mean ostial diameters and carina-to-carina distance were all comparable to CT without statistical significance. Ostial diameters and carina-to-carina distance also showed moderate to high correlation (r = 0.52-0.75) except for RIPV (r = 0.20). Qualitative ratings showed good agreement without between-rater differences. Average procedure time was 143.7 ± 43.7 min, with average radiofrequency time 31.6 ± 10.2 min. All patients achieved ablation success, and no immediate complications were observed. CONCLUSION: DL algorithm integration with ICE demonstrated considerable accuracy compared to CT and qualitative physician assessment. The feasibility of ICE with this algorithm can potentially further streamline AF ablation workflow.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Inteligência Artificial , Estudos de Viabilidade , Ecocardiografia/métodos , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Imageamento Tridimensional/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Algoritmos , Ablação por Cateter/métodos
17.
Europace ; 25(12)2023 12 06.
Artigo em Inglês | MEDLINE | ID: mdl-38064697

RESUMO

AIMS: Catheter ablation (CA) is an established treatment for atrial fibrillation (AF). A computed tomography (CT) may be performed before ablation to evaluate the anatomy of pulmonary veins. The aim of this study is to investigate the prevalence of patients with coronary artery disease (CAD) detected by cardiac CT scan pre-ablation and to evaluate the impact of CAD and revascularization on outcomes after AF ablation. METHODS AND RESULTS: All consecutive patients with AF diagnosis, hospitalized at Universitair Ziekenhuis Brussel, Belgium, between 2015 and 2019, were prospectively screened for enrolment in the study. Inclusion criteria were (i) AF diagnosis, (ii) first procedure of AF ablation with cryoballoon CA, and (iii) contrast CT scan performed pre-ablation. A total of 576 consecutive patients were prospectively included and analysed in this study. At CT scan, 122 patients (21.2%) were diagnosed with CAD, of whom 41 patients (7.1%) with critical CAD. At survival analysis, critical CAD at CT scan was a predictor of atrial tachyarrhythmia (AT) recurrence during the follow-up, only in Cox univariate analysis [hazard ratio (HR) = 1.79] but was not an independent predictor in Cox multivariate analysis. At Cox multivariate analysis, independent predictors of AT recurrence were as follows: persistent AF (HR = 2.93) and left atrium volume index (HR = 1.04). CONCLUSION: In patients undergoing CT scan before AF ablation, critical CAD was diagnosed in 7.1% of patients. Coronary artery disease and revascularization were not independent predictors of recurrence; thus, in this patient population, AF ablation should not be denied and can be performed together with CAD treatment.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Doença da Artéria Coronariana , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/epidemiologia , Doença da Artéria Coronariana/cirurgia , Resultado do Tratamento , Átrios do Coração , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva
18.
Europace ; 25(3): 896-904, 2023 03 30.
Artigo em Inglês | MEDLINE | ID: mdl-36738245

RESUMO

AIMS: The multielectrode radiofrequency balloon catheter (RFB) has been developed to achieve safe and effective pulmonary vein isolation (PVI) for atrial fibrillation (AF) ablation. This single-centre study aimed to evaluate the midterm clinical outcome and predictors of single-shot PVI with the novel RFB. METHODS AND RESULTS: All consecutive patients with symptomatic paroxysmal or persistent AF undergoing first-time PVI with the RFB were prospectively included. Clinical and procedural parameters were systematically collected. The primary safety endpoint was defined as any major periprocedural complications. The primary efficacy endpoint consisted of freedom from any atrial tachyarrhythmias (ATas) lasting >30 s during the follow-up after a 3-month blanking period. Persistent single-shot PVI was defined as PVI achieved with a single RFB application without acute reconnection. A total of 104 consecutive patients (mean age 64.3 ± 11.4 years, 56.7% males) were included. 15 patients (14.4%) presented with persistent AF. The procedure time was 59.0 min with a dwell time of 20.0 min. One major complication occurred in one patient. At a mean follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. ATas occurred in 14 patients, 11/69 patients (15.9%) with paroxysmal AF and 3/13 (23.1%) with persistent AF. The best cut-offs to predict persistent single-shot PVI were impedance drop >19.2 Ω [area under the receiver operator characteristic curve (AUC) 0.74] and temperature rise >11.1° C (AUC 0.77). CONCLUSION: In a large cohort of patients undergoing PVI with the RFB, the complication rate was 1%. At a mid-term follow-up of 10.1 ± 5.3 months, freedom from ATas was 82.9%. Specific cut-offs of impedance drop and temperature rise may be useful to predict persistent single-shot isolation.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Resultado do Tratamento , Seguimentos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Taquicardia/cirurgia , Catéteres , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
19.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36942834

RESUMO

AIMS: This study aimed to examine the clinical benefits of targeted ablation of all Premature ventricular complex (PVC) morphologies vs. predominant PVC only. METHODS AND RESULTS: A total of 171 consecutive patients with reduced left ventricular ejection fraction (LVEF) and ≥2 PVC morphology with high burden (>10%/day) undergoing their first ablation procedure were included in the analysis. At the initial procedure, prevalent PVC alone was ablated in the majority. However, at the redo, all PVC morphologies were targeted for ablation. : At the first procedure, 152 (89%) patients received ablation of the dominant PVC only. In the remaining 19 (11%) patients, all PVC morphologies were ablated. At two years, high PVC burden was detected in 89 (52%) patients. Repeat procedure was performed in 78 of 89, where all PVC morphologies were ablated. At 5 years after the repeat procedure, 71 (91%) had PVC burden of <5% [3.8 ± 1.1% vs. 15.4 ± 4.3% in successful vs. failed subjects (P < 0.001)]. In patients with low PVC burden after the initial procedure, LVEF improved from 37.5% to 41.6% [mean difference (MD): 3.39 ± 2.9%, P < 0.001], whereas a reduction in LVEF from 39.8% to 34.5% (MD: 6.45 ± 4.7%, P < 0.001) was recorded in patients with high PVC burden. One year after the repeat procedure, LVEF improved from 36.2% to 41.7% (MD: 5.5 ± 4.3%, P < 0.001) in patients with successful ablation. CONCLUSION: In this observational series, ablation of all PVC morphologies was associated with significantly lower PVC burden and improvement of LVEF at long-term follow-up, compared with ablation of the dominant morphology only.


Assuntos
Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/complicações
20.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37246904

RESUMO

AIMS: Hybrid atrial fibrillation (AF) ablation is a promising approach in non-paroxysmal AF. The aim of this study is to assess the long-term outcomes of hybrid ablation in a large cohort of patients after both an initial and as a redo procedure. METHODS AND RESULTS: All consecutive patients undergoing hybrid AF ablation at UZ Brussel from 2010 to 2020 were retrospectively evaluated. Hybrid AF ablation was performed in a one-step procedure: (i) thoracoscopic ablation followed by (ii) endocardial mapping and eventual ablation. All patients received PVI and posterior wall isolation. Additional lesions were performed based on clinical indication and physician judgement. Primary endpoint was freedom from atrial tachyarrhythmias (ATas). A total of 120 consecutive patients were included, 85 patients (70.8%) underwent hybrid AF ablation as first procedure (non-paroxysmal AF 100%), 20 patients (16.7%) as second procedure (non-paroxysmal AF 30%), and 15 patients (12.5%) as third procedure (non-paroxysmal AF 33.3%). After a mean follow-up of 62.3 months ± 20.3, a total of 63 patients (52.5%) experienced ATas recurrence. Complications occurred in 12.5% of patients. There was no difference in ATas between patients undergoing hybrid as first vs. redo procedure (P = 0.53). Left atrial volume index and recurrence during blanking period were independent predictors of ATas recurrence. CONCLUSION: In a large cohort of patients undergoing hybrid AF ablation, the survival from ATas recurrence was 47.5% at ≈5 years follow-up. There was no difference in clinical outcomes between patients undergoing hybrid AF ablation as first procedure or as a redo.


Assuntos
Técnicas de Ablação , Fibrilação Atrial , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Seguimentos , Átrios do Coração , Estudos Retrospectivos , Taquicardia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA