Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 137
Filtrar
1.
Artigo em Inglês | MEDLINE | ID: mdl-38887842

RESUMO

INTRODUCTION: Four-dimensional (4D) intracardiac echocardiography (ICE) is a novel cardiac imaging modality that has been applied to various workflows, including catheter ablation, tricuspid valve repair, and left atrial appendage occlusion (LAAO). The use of this type of advanced ICE imaging may ultimately allow for the replacement of transesophageal echocardiography (TEE) for LAAO, providing comparable imaging quality while eliminating the need for general anesthesia. METHODS: Based on our initial clinical experience with 4D ICE in LAAO, we have developed an optimized workflow for the use of the NUVISION™ 4D ICE Catheter in conjunction with the GE E95 and S70N Ultrasound Systems in LAAO. In this manuscript, we provide a step-by-step guide to using 4D ICE in conjunction with compatible imaging consoles. We have also evaluated the performance of 4D ICE with the NUVISION Ultrasound Catheter versus TEE in one LAAO case and present those results here. RESULTS: In our comparison of 4D ICE using our optimized workflow with TEE in an LAAO case, ICE LAA measurements were similar to those from TEE. The best image resolution was seen via ICE in 2-dimensional and multislice modes (triplane and biplane). The FlexiSlice multiplanar reconstruction tool, which creates an en-face image derived from a 4D volume set, also provided valuable information but yielded slightly lower image quality, as expected for these volume-derived images. For this case, comparable images were obtained with TEE and ICE but with less need to reposition the ICE catheter. CONCLUSION: The use of optimized 4D ICE catheter workflow recommendations allows for efficient LAAO procedures, with higher resolution imaging, comparable to TEE.

2.
J Cardiovasc Electrophysiol ; 35(2): 278-287, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38073051

RESUMO

INTRODUCTION: Transvenous lead extraction (TLE), while mostly a safe procedure, has risk of serious periprocedural complications. As such, overnight hospitalization remains a routine practice. In our center, we routinely discharge patients on the same day following an uncomplicated TLE. METHODS: This is a retrospective study of 265 consecutive patients who underwent uncomplicated TLE in our center between 2019 and 2021. Same-day discharge (SDD) patients are compared with those who stayed at least overnight for observation after the TLE procedure (non-SDD group). To assess the safety of an SDD strategy after uncomplicated TLE, the main study endpoint was to compare the rate of major procedure-related complications at 1-, 7-, and 30-days. To identify the factors influencing the operator's decision to discharge the patient on the same day, the secondary endpoint was to analyze clinical and procedural predictors of SDD. RESULTS: A total of 153 patients were discharged the same day after uncomplicated TLE (SDD), while 112 stayed at least overnight after the procedure (non-SDD). There was no significant difference in major procedure-related complications at 1-day (SDD 0% vs. non-SDD 1.8%, p value = ns), while patients in the SDD group had a lower rate of 7- and 30-day complications when compared with those in the non-SDD group (2.1% vs. 8.2%, p value = .0308; and 3.5% vs. 16%, p value = .0049, respectively). Noninfectious indication for TLE (OR 16.1, 95% confidence interval [CI] 4.29-77.6) and procedure end time before 12:00 (OR 2.82, 95% CI 1.11-7.27) were the only independent predictors of SDD. CONCLUSION: SDD discharge following uncomplicated TLE in selected patients (i.e., those without device infection and when the TLE procedure is completed in the morning) is feasible and safe.


Assuntos
Hospitalização , Alta do Paciente , Humanos , Remoção de Dispositivo , Estudos de Viabilidade , Estudos Retrospectivos , Resultado do Tratamento
3.
Eur Heart J ; 44(35): 3327-3335, 2023 09 14.
Artigo em Inglês | MEDLINE | ID: mdl-37387689

RESUMO

AIMS: Management of patients with atrial fibrillation (AF) and concomitant heart failure (HF) remains complex. The Antwerp score, based on four parameters [QRS >120 ms (2 points), known aetiology (2 points), paroxysmal AF (1 point), severe atrial dilation (1 point)] adequately estimated the probability of left ventricular ejection fraction (LVEF) recovery after AF ablation in a single-centre cohort. The present study aims to externally validate this prediction model in a large European multi-centre cohort. METHODS AND RESULTS: A total of 605 patients (61.1 ± 9.4 years, 23.8% females, 79.8% with persistent AF) with HF and impaired LVEF (<50%) undergoing AF ablation in 8 European centres were retrospectively identified. According to the LVEF changes at 12-month echocardiography, 427 (70%) patients fulfilled the '2021 Universal Definition of HF' criteria for LVEF recovery and were defined as 'responders'. External validation of the score yielded good discrimination and calibration {area under the curve 0.86 [95% confidence interval (CI) 0.82-0.89], P < .001; Hosmer-Lemeshow P = .29}. Patients with a score < 2 had a 93% probability of LVEF recovery as opposed to only 24% in patients with a score > 3. Responders experienced more often positive ventricular remodelling [odds ratio (OR) 8.91, 95% CI 4.45-17.84, P < .001], fewer HF hospitalizations (OR 0.09, 95% CI 0.05-0.18, P < .001) and lower mortality (OR 0.11, 95% CI 0.04-0.31, P < .001). CONCLUSION: In this multi-centre study, a simple four-parameter score predicted LVEF recovery after AF ablation in patients with HF and discriminated clinical outcomes. These findings support the use of the Antwerp score to standardize shared decision-making regarding AF ablation referral in future clinical studies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Insuficiência Cardíaca , Feminino , Humanos , Masculino , Fibrilação Atrial/complicações , Fibrilação Atrial/cirurgia , Volume Sistólico , Função Ventricular Esquerda , Estudos Retrospectivos , Resultado do Tratamento
4.
J Cardiovasc Electrophysiol ; 34(10): 2136-2144, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-36069138

RESUMO

This article reviews the latest available data in regard to the diagnosis, management, and intervention of both central and peri-device leaks that arise after left atrial appendage closure (LAAC). The aim of this article is to have a better understanding of both addressing leaks arising after LAAC, and which interventions and closure methods are best served for each type of residual leak based on etiology, size, and operator experience.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos
5.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378783

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Prevalência , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos
6.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493490

RESUMO

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Assuntos
Miocardite , Sarcoidose , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Gadolínio , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética/efeitos adversos , Miocardite/complicações , Prognóstico , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda
7.
Catheter Cardiovasc Interv ; 101(6): 1144-1153, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-36924020

RESUMO

AIMS: To compare outcomes of patients who underwent left atrial appendage occlusion (LAAO) for nonvalvular atrial fibrillation (NVAF) and contraindication to anticoagulants due to history of either gastrointestinal (GI) or intracranial (IC) bleeding. METHODS: Patients with NVAF that underwent LAAO for GI or IC bleeding from seven centers were included in this observational study. Baseline characteristics, procedural features, and follow-up data were collected, and compared between the two groups. The primary outcomes were incidence of ischemic and hemorrhagic events at 12-month. RESULTS: Six hundred twenty-eight patients were included, 57% with previous GI-bleeding, and 43% with previous IC-bleeding. Median CHA 2 DS 2-VASc score was 4 (interquartile range [IQRs]: 3-5) for both GI-bleeding and IC-bleeding patients, while GI-bleeding patients had a higher HAS-BLED score (4 [IQRs: 3-4] vs. 3 [IQRs]: 2-3]; p = 0.001). At 12-month follow-up, relative risk reduction for stroke was similar between the two groups. The GI-bleeding group had more hemorrhagic events compared to IC-bleeding group (any bleeding 8.4% vs. 3.2%; p = 0.012; major bleeding BARC 3-5: 4.3% vs. 1.8; p = 0.010). At multivariate analysis history of GI bleeding was an independent predictor of hemorrhagic events (adjusted HR: 2.39, 95% confidence interval: 1.02-5.63; p = 0.047). CONCLUSIONS: Outcomes after LAAO may be affected by the different indications for the procedure. In our study, GI-bleeding and IC-bleeding as indication to LAAO differ in their baseline characteristics. LAAO confirms its efficacy in ischemic risk reduction in both groups, while GI bleeding seems to be an independent predictor of bleeding recurrence at 12 months behind the antithrombotic regimen.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Resultado do Tratamento , Hemorragia Gastrointestinal/diagnóstico , Hemorragia Gastrointestinal/etiologia , Hemorragia Gastrointestinal/prevenção & controle , Hemorragias Intracranianas/etiologia , Sistema de Registros , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Lógica
8.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36942834

RESUMO

AIMS: This study aimed to examine the clinical benefits of targeted ablation of all Premature ventricular complex (PVC) morphologies vs. predominant PVC only. METHODS AND RESULTS: A total of 171 consecutive patients with reduced left ventricular ejection fraction (LVEF) and ≥2 PVC morphology with high burden (>10%/day) undergoing their first ablation procedure were included in the analysis. At the initial procedure, prevalent PVC alone was ablated in the majority. However, at the redo, all PVC morphologies were targeted for ablation. : At the first procedure, 152 (89%) patients received ablation of the dominant PVC only. In the remaining 19 (11%) patients, all PVC morphologies were ablated. At two years, high PVC burden was detected in 89 (52%) patients. Repeat procedure was performed in 78 of 89, where all PVC morphologies were ablated. At 5 years after the repeat procedure, 71 (91%) had PVC burden of <5% [3.8 ± 1.1% vs. 15.4 ± 4.3% in successful vs. failed subjects (P < 0.001)]. In patients with low PVC burden after the initial procedure, LVEF improved from 37.5% to 41.6% [mean difference (MD): 3.39 ± 2.9%, P < 0.001], whereas a reduction in LVEF from 39.8% to 34.5% (MD: 6.45 ± 4.7%, P < 0.001) was recorded in patients with high PVC burden. One year after the repeat procedure, LVEF improved from 36.2% to 41.7% (MD: 5.5 ± 4.3%, P < 0.001) in patients with successful ablation. CONCLUSION: In this observational series, ablation of all PVC morphologies was associated with significantly lower PVC burden and improvement of LVEF at long-term follow-up, compared with ablation of the dominant morphology only.


Assuntos
Ablação por Cateter , Disfunção Ventricular Esquerda , Complexos Ventriculares Prematuros , Humanos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Volume Sistólico/fisiologia , Função Ventricular Esquerda/fisiologia , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/cirurgia , Complexos Ventriculares Prematuros/complicações
9.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37889200

RESUMO

AIMS: Atrial fibrillation (AF) and chronic kidney disease (CKD) often coexist and share an increased risk of thrombo-embolism (TE). CKD concomitantly predisposes towards a pro-haemorrhagic state. Our aim was to evaluate the prognostic value of CKD in patients undergoing percutaneous left atrial appendage occlusion (LAAO). METHODS AND RESULTS: A total of 2124 consecutive AF patients undergoing LAAO were categorized into CKD stage 1+2 (n = 1089), CKD stage 3 (n = 796), CKD stage 4 (n = 170), and CKD stage 5 (n = 69) based on the estimated glomerular filtration rate at baseline. The primary endpoint included cardiovascular (CV) mortality, TE, and major bleeding. The expected annual TE and major bleeding risks were estimated based on the CHA2DS2-VASc and HAS-BLED scores. A non-significant higher incidence of major peri-procedural adverse events (1.7 vs. 2.3 vs. 4.1 vs. 4.3) was observed with worsening CKD (P = 0.14). The mean follow-up period was 13 ± 7 months (2226 patient-years). In comparison to CKD stage 1+2 as a reference, the incidence of the primary endpoint was significantly higher in CKD stage 3 (log-rank P-value = 0.04), CKD stage 4 (log-rank P-value = 0.01), and CKD stage 5 (log-rank P-value = 0.001). Left atrial appendage occlusion led to a TE risk reduction (RR) of 72, 66, 62, and 41% in each group. The relative RR of major bleeding was 58, 44, 51, and 52%, respectively. CONCLUSION: Patients with moderate-to-severe CKD had a higher incidence of the primary composite endpoint. The relative RR in the incidence of TE and major bleeding was consistent across CKD groups.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Insuficiência Renal Crônica , Acidente Vascular Cerebral , Humanos , Apêndice Atrial/cirurgia , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Prognóstico , Resultado do Tratamento , Estudos Retrospectivos , Hemorragia/induzido quimicamente , Insuficiência Renal Crônica/complicações , Insuficiência Renal Crônica/diagnóstico , Insuficiência Renal Crônica/epidemiologia , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Anticoagulantes/efeitos adversos
10.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38225176

RESUMO

AIMS: Left atrial appendage (LAA) imaging is critical during percutaneous occlusion procedures. 3D-intracardiac echocardiography (ICE) features direct visualization of LAA from multiple cross-sectional planes at a time. We aimed at reporting procedural success of 3D-ICE-guided LAA occlusion and the correlation between pre-procedural transoesophageal echocardiography (TEE) and intraprocedural 3D-ICE for LAA sizing. METHODS AND RESULTS: Among 274 patients undergoing left atrial appendage occlusion (LAAO) with a Watchman FLX, periprocedural ICE guidance was achieved via a commercially available 2D-ICE catheter (220 patients) or a novel (NUVISION™) 3D-ICE one (54 patients). Primary endpoint was a composite of procedural success and LAA sealing at follow-up TEE. Secondary endpoint was a composite of periprocedural device recapture/resizing plus presence of leaks ≥ 3 mm at follow-up TEE. 3D-ICE measurements of maximum landing zone correlated highly with pre-procedural TEE reference values [Pearson's: 0.94; P < 0.001; bias: -0.06 (-2.39, 2.27)]. The agreement between 3D-ICE-based device selection and final device size was 96.3% vs. 79.1% with 2D-ICE (P = 0.005). The incidence of the primary endpoint was 98.1% with 3D-ICE and 97.3% with 2D-ICE (P = 0.99). 2D-ICE patients had a trend towards a higher incidence of periprocedural device recapture/redeployment (31.5% vs. 44.5%; P = 0.09). The secondary endpoint occurred in 31.5% of 3D-ICE patients vs. 45.9% of 2D-ICE ones (P = 0.065). CONCLUSION: Intracardiac echocardiography-guided LAAO showed a very high success, with no major adverse events. A very high level of agreement for LAA sizing was found between pre-procedural TEE and periprocedural 3D-ICE. 3D-ICE performed significantly better than 2D-ICE for FLX size selection and may provide better guidance during device deployment.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Humanos , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Estudos Transversais , Resultado do Tratamento , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Cateterismo Cardíaco , Ecocardiografia Transesofagiana/métodos , Ecocardiografia/métodos
11.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
12.
Catheter Cardiovasc Interv ; 99(6): 1867-1876, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35233927

RESUMO

BACKGROUND: Though infrequent, incomplete left atrial appendage closure (LAAC) may result from residual leaks. Percutaneous closure has been described though data is limited. METHODS: We compiled a registry from four centers of patients undergoing percutaneous closure of residual leaks following LAAC via surgical means or with the Watchman device. Leak severity was classified as none (no leak), mild (1-2 mm), moderate (3-4 mm), or severe (≥5 mm). Procedural and clinical success was defined as the elimination of leak or mild residual leak at the conclusion of the procedure or follow-up, respectively. RESULTS: Of 72 (age 72.2 ± 9.2 years; 67% male) patients, 53 had undergone prior LAAC using the Watchman device and 19 patients surgical LAAC. Mean CHADS2 -VA2 Sc score was 4.0 ± 1.8. The median leak size was 5 mm, range: 2-13). A total of 13 received Amplatzer Vascular Plug-II, 18 received Amplatzer Duct Occluder-II and 40 patients received coils. One underwent closure using a 21 mm-Watchman. Procedural success was 94%. Zero surgical and nine Watchman patients (13%) had a residual leak at procedural-end (five mild, three moderate, and one severe)-only one patient had no reduction in leak size. Overall leak size reduction was 94%. Two (3%) had intraoperative pericardial effusion. There were no device embolizations, device-related thrombi, or procedural deaths. Clinical success was maintained at 94%. Two had cerebrovascular accidents-at 2 days (transient ischemic attack) and 10 months postprocedure. Two had major bleeding outside the 30-day periprocedural window. CONCLUSION: Percutaneous closure of residual leaks following left atrial appendage closure is feasible and associated with good outcomes. The procedural risk appears to be satisfactory.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Dispositivo para Oclusão Septal , Acidente Vascular Cerebral , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Cateterismo Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Resultado do Tratamento
13.
J Cardiovasc Electrophysiol ; 32(8): 2337-2339, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34176172

RESUMO

Herein, we present a case of laser-assisted extraction of a retained lead remnant following incomplete removal of an implantable cardiac defibrillator system implanted via a left femoral approach.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Desfibriladores Implantáveis/efeitos adversos , Remoção de Dispositivo , Eletrodos Implantados , Humanos , Veia Ilíaca/diagnóstico por imagem , Veia Ilíaca/cirurgia , Lasers , Marca-Passo Artificial/efeitos adversos
15.
J Cardiovasc Electrophysiol ; 32(10): 2781-2784, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34411376

RESUMO

INTRODUCTION: Watchman FLX has been recently approved for left atrial appendage occlusion (LAAO) in the US. Intracardiac echocardiography (ICE) - which is already commonly used to guide trans-septal access - can serve as an alternative to TEE, simplifying the procedure and reducing associated costs. Herein, we report our experience with ICE-guided LAAO with Watchman FLX. METHODS AND RESULTS: This cohort study included the first 190 consecutive patients who underwent LAAO with Watchman FLX in our center. LAAO was successful in all patients without significant peri-procedural, device-related complications in either group. Compared to TEE, we observed a significant reduction in procedural times when using ICE. In addition, there was a potentially clinically relevant reduction in fluoroscopy dose, mainly secondary to fewer cine acquisition runs. At follow-up, no cases of device embolism were noted, whereas the rate of device-related thrombosis and peri-device leaks were comparable between groups. CONCLUSION: ICE-guided LAAO with Watchman FLX is safe and feasible, with a significant reduction in procedural time and potential reduction in fluoroscopy dose when compared to TEE.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Cateterismo Cardíaco/efeitos adversos , Estudos de Coortes , Ecocardiografia Transesofagiana , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção
16.
J Cardiovasc Electrophysiol ; 32(8): 2165-2170, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-33942420

RESUMO

OBJECTIVE: To assess the safety and efficacy of a novel immunosuppressive regimen-combination Methotrexate/Prednisone (cMtx/P)-in the management of severe refractory rPPP. METHODS: In this multicenter, nonrandomized, retrospective, observational study, 408 consecutive patients diagnosed with persistent rPPP between 2017 and 19 were included. Patients with refractory symptoms despite 3 months of conventional therapy were initiated on a 4-week regimen of oral steroids. Persistence of symptoms at this point, that is, rPPP (n = 25; catheter based = 18, open surgical = 7) prompted therapy with Methotrexate (7.5-15 mg weekly) with folate supplementation along with low dose prednisone (5 mg PO) for a further 3 months. Patients were followed for a total of 11.3 ± 1.8 months. RESULTS: Treatment refractory rPPP occurred in 6.1% of the study population prompting immunosuppressive therapy with cMtx/P. All patients demonstrated complete symptom resolution following 3 months of treatment with an 85% decline in clinically significant pericardial effusions. One patient developed recurrent pericarditis during the 11-month follow-up. Therapy was well tolerated with no significant drug related adverse effects. CONCLUSION: cMtx/P therapy is a safe and effective adjunct in the management of rPPP refractory to standard therapy.


Assuntos
Imunossupressores , Pericardite , Humanos , Imunossupressores/efeitos adversos , Metotrexato/efeitos adversos , Pericardite/induzido quimicamente , Pericardite/diagnóstico , Pericardite/tratamento farmacológico , Prednisona/efeitos adversos , Estudos Retrospectivos , Resultado do Tratamento
17.
J Cardiovasc Electrophysiol ; 32(4): 973-981, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33442937

RESUMO

BACKGROUND: The creation of effective and permanent lesions is a crucial factor in determining the success rate of atrial fibrillation (AF) ablation. By increasing the efficacy of radiofrequency (RF) energy-mediated lesion formation, half-normal saline (HNS) as an irrigant for open-irrigated ablation catheters has the potential to reduce procedural times and improve acute and long-term outcomes. METHODS: This is a double-blind randomized clinical trial of 99 patients undergoing first-time RF catheter ablation for AF. Patients enrolled were randomly assigned in a 1:1 fashion to perform ablation using HNS or normal saline (NS) as an irrigant for the ablation catheter. RESULTS: The use of HNS is associated with shorter RF times (26 vs. 33 min; p = .02) with comparable procedure times (104 vs. 104 min). The rate of acute pulmonary vein reconnections (16% vs. 18%) was comparable, with a median of 1 vein reconnection in the HNS arm versus 2 in the NS arm. There was no difference in procedure-related complications, including the incidence of postprocedural hyponatremia when using HNS. Over the 1-year follow-up, there is no significant difference between the HNS and NS with respect to the recurrence of any atrial arrhythmia (off antiarrhythmic drugs [AAD]: 47% vs. 52%; hazard ratio [HR]: 1.17, 95% confidence interval [CI]: 0.66-2.06; off/on AAD: 66% vs. 66%, HR: 1.06, 95% CI: 0.53-2.12), with a potential benefit of using HNS when considering the paroxysmal AF cohort (on/off AAD 73% vs. 62%, HR: 0.72, 95% CI: 0.19-2.70). CONCLUSIONS: In a mixed cohort of patients undergoing first-time AF ablation, irrigation of open-irrigated RF ablation catheters with HNS is associated with shorter RF times, with a comparably low rate of procedure-related complications. In the long term, there is no significant difference with respect to the recurrence of any atrial arrhythmia. Larger studies with a more homogeneous population are necessary to determine whether HNS improves clinical outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Catéteres , Desenho de Equipamento , Humanos , Veias Pulmonares/cirurgia , Recidiva , Solução Salina , Resultado do Tratamento
18.
J Cardiovasc Electrophysiol ; 32(9): 2441-2450, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-34260115

RESUMO

BACKGROUND: Atrioesophageal fistula (AEF) is a worrisome complication of atrial fibrillation (AF) ablation. Its clinical manifestations and time course are unpredictable and may contribute to diagnostic and treatment delays. We conducted a systematic review of all available cases of AEF, aiming at characterizing clinical presentation, time course, diagnostic pitfalls, and outcomes. METHODS: The digital search retrieved 150 studies containing 257 cases, 238 (92.6%) of which with a confirmed diagnosis of AEF and 19 (7.4%) of pericardioesophageal fistula. RESULTS: The median time from ablation to symptom onset was 21 days (interquartile range [IQR]: 11-28). Neurological abnormalities were documented in 75% of patients. Compared to patients seen by a specialist, those evaluated at a walk-in clinic or community hospital had a significantly greater delay between symptom onset and hospital admission (median: 2.5 day [IQR: 1-8] vs. 1 day [IQR: 1-5); p = .03). Overall, 198 patients underwent a chest scan (computed tomography [CT]: 192 patients and magnetic resonance imaging [MRI]: 6 patients), 48 (24.2%; 46 CT and 2 MRI) of whom had normal/unremarkable findings. Time from hospital admission to diagnostic confirmation was significantly longer in patients with a first normal/unremarkable chest scan (p < .001). Overall mortality rate was 59.3% and 26.0% survivors had residual neurological deficits at the time of discharge. CONCLUSIONS: Since healthcare professionals of any specialty might be involved in treating AEF patients, awareness of the clinical manifestations, diagnostic pitfalls, and time course, as well as an early contact with the treating electrophysiologist for a coordinated interdisciplinary medical effort, are pivotal to prevent diagnostic delays and reduce mortality.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fístula Esofágica , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Fístula Esofágica/diagnóstico por imagem , Fístula Esofágica/etiologia , Fístula Esofágica/cirurgia , Átrios do Coração/cirurgia , Humanos , Imageamento por Ressonância Magnética , Tomografia Computadorizada por Raios X
19.
Europace ; 23(12): 1939-1949, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34417816

RESUMO

AIMS: We evaluated the efficacy of an ablation strategy empirically targeting pulmonary veins (PVs) and posterior wall (PW) and the prevalence and clinical impact of extrapulmonary trigger inducibility and ablation in a large cohort of patients with persistent atrial fibrillation (PerAF). METHODS AND RESULTS: A total of 1803 PerAF patients were prospectively enrolled. All patients underwent pulmonary vein antrum isolation (PVAI) extended to the entire PW. A standardized protocol was performed to confirm persistent PVAI and elicit any triggers originating from non-PV sites. All non-PV triggers initiating sustained atrial tachyarrhythmias were ablated. Ablation of non-PV sites triggering non-sustained runs (<30 s) of atrial tachyarrhythmias or promoting frequent premature atrial complexes (≥10/min) was left to operator's discretion. Overall, 1319 (73.2%) patients had documented triggers from non-PV areas. After 17.4 ± 8.5 months of follow-up, the cumulative freedom from atrial tachyarrhythmias among patients without inducible non-PV triggers (n = 484) was 70.2%. Patients with ablation of induced non-PV triggers had a significantly higher arrhythmia control than those whose triggers were not ablated (67.9% vs. 39.4%, respectively; P < 0.001). After adjusting for clinically relevant variables, patients in whom non-PV triggers were documented but not ablated had an increased risk of arrhythmia relapse (hazard ratio: 2.39; 95% confidence interval: 2.01-2.83; P < 0.001). CONCLUSION: Pulmonary vein antrum isolation extended to the entire PW might provide acceptable long-term arrhythmia-free survival in PerAF patients without inducible non-PV triggers. In our population of PerAF patients, non-PV triggers could be elicited in ∼70% of PerAF patients and their elimination significantly improved outcomes.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Humanos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
20.
Pacing Clin Electrophysiol ; 44(9): 1641-1645, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34033130

RESUMO

We describe a case of pacemaker implant guided by intracardiac echocardiography and three-dimensional anatomical mapping in a pregnant patient, with no peri-procedural use of radiation.


Assuntos
Ecocardiografia Tridimensional , Marca-Passo Artificial , Implantação de Prótese/métodos , Síncope/diagnóstico por imagem , Síncope/terapia , Ultrassonografia de Intervenção , Adulto , Eletrocardiografia , Mapeamento Epicárdico , Feminino , Humanos , Gravidez
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA