Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 73
Filtrar
1.
N Engl J Med ; 382(9): 799-809, 2020 02 27.
Artigo em Inglês | MEDLINE | ID: mdl-31995682

RESUMO

BACKGROUND: There are scant data on long-term clinical outcomes and bioprosthetic-valve function after transcatheter aortic-valve replacement (TAVR) as compared with surgical aortic-valve replacement in patients with severe aortic stenosis and intermediate surgical risk. METHODS: We enrolled 2032 intermediate-risk patients with severe, symptomatic aortic stenosis at 57 centers. Patients were stratified according to intended transfemoral or transthoracic access (76.3% and 23.7%, respectively) and were randomly assigned to undergo either TAVR or surgical replacement. Clinical, echocardiographic, and health-status outcomes were followed for 5 years. The primary end point was death from any cause or disabling stroke. RESULTS: At 5 years, there was no significant difference in the incidence of death from any cause or disabling stroke between the TAVR group and the surgery group (47.9% and 43.4%, respectively; hazard ratio, 1.09; 95% confidence interval [CI], 0.95 to 1.25; P = 0.21). Results were similar for the transfemoral-access cohort (44.5% and 42.0%, respectively; hazard ratio, 1.02; 95% CI, 0.87 to 1.20), but the incidence of death or disabling stroke was higher after TAVR than after surgery in the transthoracic-access cohort (59.3% vs. 48.3%; hazard ratio, 1.32; 95% CI, 1.02 to 1.71). At 5 years, more patients in the TAVR group than in the surgery group had at least mild paravalvular aortic regurgitation (33.3% vs. 6.3%). Repeat hospitalizations were more frequent after TAVR than after surgery (33.3% vs. 25.2%), as were aortic-valve reinterventions (3.2% vs. 0.8%). Improvement in health status at 5 years was similar for TAVR and surgery. CONCLUSIONS: Among patients with aortic stenosis who were at intermediate surgical risk, there was no significant difference in the incidence of death or disabling stroke at 5 years after TAVR as compared with surgical aortic-valve replacement. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estudos de Coortes , Ecocardiografia , Feminino , Nível de Saúde , Humanos , Incidência , Análise de Intenção de Tratamento , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Resultado do Tratamento
2.
N Engl J Med ; 374(17): 1609-20, 2016 04 28.
Artigo em Inglês | MEDLINE | ID: mdl-27040324

RESUMO

BACKGROUND: Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients. METHODS: We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort. RESULTS: The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation. CONCLUSIONS: In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Feminino , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Complicações Pós-Operatórias/mortalidade , Fatores de Risco , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Ultrassonografia
3.
Circulation ; 129(22): 2287-96, 2014 Jun 03.
Artigo em Inglês | MEDLINE | ID: mdl-24682346

RESUMO

BACKGROUND: Allogeneic mesenchymal precursor cells (MPCs) injected during left ventricular assist device (LVAD) implantation may contribute to myocardial recovery. This trial explores the safety and efficacy of this strategy. METHODS AND RESULTS: In this multicenter, double-blind, sham-procedure controlled trial, 30 patients were randomized (2:1) to intramyocardial injection of 25 million MPCs or medium during LVAD implantation. The primary safety end point was incidence of infectious myocarditis, myocardial rupture, neoplasm, hypersensitivity reaction, and immune sensitization (90 days after randomization). Key efficacy end points were functional status and ventricular function while temporarily weaned from LVAD support (90 days after randomization). Patients were followed up until transplant or 12 months after randomization, whichever came first. Mean age was 57.4 (±13.6) years, mean left ventricular ejection fraction was 18.1%, and 66.7% were destination therapy LVADs. No safety events were observed. Successful temporary LVAD weaning was achieved in 50% of MPC and 20% of control patients at 90 days (P=0.24); the posterior probability that MPCs increased the likelihood of successful weaning was 93%. At 90 days, 3 deaths (30%) occurred in control patients, and none occurred in MPC patients. Mean left ventricular ejection fraction after successful wean was 24.0% (MPC=10) and 22.5% (control=2; P=0.56). At 12 months, 30% of MPC patients and 40% of control patients were successfully temporarily weaned from LVAD support (P=0.69), and 6 deaths (30%) occurred in MPC patients. Donor-specific HLA sensitization developed in 2 MPC and 3 control patients and resolved by 12 months. CONCLUSIONS: In this preliminary trial, administration of MPCs appeared to be safe, and there was a potential signal of efficacy. Future studies will evaluate the potential for higher or additional doses to enhance the ability to wean LVAD recipients off support. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01442129.


Assuntos
Insuficiência Cardíaca/terapia , Coração Auxiliar , Transplante de Células-Tronco Mesenquimais/métodos , Células-Tronco Mesenquimais , Disfunção Ventricular Esquerda/terapia , Adulto , Idoso , Terapia Baseada em Transplante de Células e Tecidos/efeitos adversos , Terapia Baseada em Transplante de Células e Tecidos/métodos , Método Duplo-Cego , Feminino , Neoplasias Cardíacas/epidemiologia , Humanos , Incidência , Masculino , Transplante de Células-Tronco Mesenquimais/efeitos adversos , Pessoa de Meia-Idade , Miocardite/epidemiologia , Resultado do Tratamento
4.
N Engl J Med ; 366(18): 1696-704, 2012 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-22443478

RESUMO

BACKGROUND: Transcatheter aortic-valve replacement (TAVR) is the recommended therapy for patients with severe aortic stenosis who are not suitable candidates for surgery. The outcomes beyond 1 year in such patients are not known. METHODS: We randomly assigned patients to transfemoral TAVR or to standard therapy (which often included balloon aortic valvuloplasty). Data on 2-year outcomes were analyzed. RESULTS: A total of 358 patients underwent randomization at 21 centers. The rates of death at 2 years were 43.3% in the TAVR group and 68.0% in the standard-therapy group (P<0.001), and the corresponding rates of cardiac death were 31.0% and 62.4% (P<0.001). The survival advantage associated with TAVR that was seen at 1 year remained significant among patients who survived beyond the first year (hazard ratio, 0.58; 95% confidence interval [CI], 0.36 to 0.92; P=0.02 with the use of the log-rank test). The rate of stroke was higher after TAVR than with standard therapy (13.8% vs. 5.5%, P=0.01), owing, in the first 30 days, to the occurrence of more ischemic events in the TAVR group (6.7% vs. 1.7%, P=0.02) and, beyond 30 days, to the occurrence of more hemorrhagic strokes in the TAVR group (2.2% vs. 0.6%, P=0.16). At 2 years, the rate of rehospitalization was 35.0% in the TAVR group and 72.5% in the standard-therapy group (P<0.001). TAVR, as compared with standard therapy, was also associated with improved functional status (P<0.001). The data suggest that the mortality benefit after TAVR may be limited to patients who do not have extensive coexisting conditions. Echocardiographic analysis showed a sustained increase in aortic-valve area and a decrease in aortic-valve gradient, with no worsening of paravalvular aortic regurgitation. CONCLUSIONS: Among appropriately selected patients with severe aortic stenosis who were not suitable candidates for surgery, TAVR reduced the rates of death and hospitalization, with a decrease in symptoms and an improvement in valve hemodynamics that were sustained at 2 years of follow-up. The presence of extensive coexisting conditions may attenuate the survival benefit of TAVR. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Cateterismo , Implante de Prótese de Valva Cardíaca/métodos , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Cateterismo Cardíaco/efeitos adversos , Doenças Cardiovasculares/etiologia , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hospitalização/estatística & dados numéricos , Humanos , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Ultrassonografia
5.
N Engl J Med ; 366(18): 1686-95, 2012 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-22443479

RESUMO

BACKGROUND: The Placement of Aortic Transcatheter Valves (PARTNER) trial showed that among high-risk patients with aortic stenosis, the 1-year survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical replacement. However, longer-term follow-up is necessary to determine whether TAVR has prolonged benefits. METHODS: At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either surgical aortic-valve replacement or TAVR. All patients were followed for at least 2 years, with assessment of clinical outcomes and echocardiographic evaluation. RESULTS: The rates of death from any cause were similar in the TAVR and surgery groups (hazard ratio with TAVR, 0.90; 95% confidence interval [CI], 0.71 to 1.15; P=0.41) and at 2 years (Kaplan-Meier analysis) were 33.9% in the TAVR group and 35.0% in the surgery group (P=0.78). The frequency of all strokes during follow-up did not differ significantly between the two groups (hazard ratio, 1.22; 95% CI, 0.67 to 2.23; P=0.52). At 30 days, strokes were more frequent with TAVR than with surgical replacement (4.6% vs. 2.4%, P=0.12); subsequently, there were 8 additional strokes in the TAVR group and 12 in the surgery group. Improvement in valve areas was similar with TAVR and surgical replacement and was maintained for 2 years. Paravalvular regurgitation was more frequent after TAVR (P<0.001), and even mild paravalvular regurgitation was associated with increased late mortality (P<0.001). CONCLUSIONS: A 2-year follow-up of patients in the PARTNER trial supports TAVR as an alternative to surgery in high-risk patients. The two treatments were similar with respect to mortality, reduction in symptoms, and improved valve hemodynamics, but paravalvular regurgitation was more frequent after TAVR and was associated with increased late mortality. (Funded by Edwards Lifesciences; ClinicalTrials.gov number, NCT00530894.).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Anticoagulantes/efeitos adversos , Anticoagulantes/uso terapêutico , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/classificação , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Hemorragia/etiologia , Heparina/efeitos adversos , Heparina/uso terapêutico , Humanos , Estimativa de Kaplan-Meier , Masculino , Inibidores da Agregação Plaquetária/efeitos adversos , Inibidores da Agregação Plaquetária/uso terapêutico , Complicações Pós-Operatórias , Falha de Prótese , Acidente Vascular Cerebral/etiologia , Taxa de Sobrevida , Resultado do Tratamento , Ultrassonografia
6.
Catheter Cardiovasc Interv ; 86(2): 316-22, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25546704

RESUMO

BACKGROUND: Transcatheter aortic valve replacement (TAVR) with the balloon-expandable Sapien transcatheter heart valve improves survival compared to standard therapy in patients with severe aortic stenosis (AS) and is noninferior to surgical aortic valve replacement (AVR) in patients at high operative risk. Nonetheless, a significant proportion of patients may require pre-emptive or emergent support with cardiopulmonary bypass (CPB) and/or intra-aortic balloon pump (IABP) during TAVR due to pre-existing comorbid conditions or as a result of procedural complications. OBJECTIVES: We hypothesized that patients who required CPB or IABP would have increased periprocedural complications and reduced long-term survival. In addition, we sought to determine whether preprocedural variables could predict the need for CPB and IABP. METHODS: The study population included 2,525 patients in the PARTNER Trial (Cohort A and B) and the continuing access registry (CAR). Patients that received CPB or IABP were compared to patients that did not receive either, and then further divided into those that received support pre-TAVR and those that were placed on support emergently. RESULTS: One-hundred sixty-three patients (6.5%) were placed on CPB and/or IABP. The use of CPB or IABP was associated with higher 1 year mortality (49.1% vs. 21.6%, P < 0.001). In multivariable analysis, utilization of CPB or IABP was an independent predictor of 30 day (HR 6.95) and 1-year (HR 2.56) mortality. Although mortality was highest in emergent cases, mortality was also greater in planned CPB and IABP cases compared with non-CPB/IABP cases (53.3% and 40.3% vs. 21.6%, P < 0.001). CONCLUSIONS: These findings indicate that CPB and IABP use in TAVR portends a poor prognosis and its utilization, particularly in the setting of pre-emptive use, needs reconsideration.


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica , Cateterismo Cardíaco/mortalidade , Ponte Cardiopulmonar/mortalidade , Implante de Prótese de Valva Cardíaca/mortalidade , Balão Intra-Aórtico/mortalidade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Ponte Cardiopulmonar/efeitos adversos , Distribuição de Qui-Quadrado , Comorbidade , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Balão Intra-Aórtico/efeitos adversos , Estimativa de Kaplan-Meier , Masculino , Análise Multivariada , Modelos de Riscos Proporcionais , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
7.
Eur Heart J ; 35(24): 1599-607, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24179072

RESUMO

AIMS: Cardiac conduction disturbances, including a left bundle branch block (LBBB), occur frequently following transcatheter aortic valve replacement (TAVR) and may be associated with adverse clinical events. This analysis examines the incidence and implications of new onset, persistent LBBB in patients undergoing TAVR with a balloon-expandable valve. METHODS AND RESULTS: Patients undergoing TAVR in the Placement of Aortic Transcatheter Valves (PARTNER) trial and continued access registries with baseline and discharge/7-day electrocardiograms were included. Prior permanent pacemaker implantation (PPI) and baseline intraventricular conduction abnormalities were exclusion criteria. Predictors of new LBBB were identified and outcomes compared between patients with and without new LBBB. New LBBB occurred in 121 of 1151 (10.5%) patients and persisted in more than half at 6 months to 1 year. The only predictor of new LBBB was prior coronary artery bypass grafting. New LBBB was not associated with significant differences in 1-year mortality, cardiovascular mortality, repeat hospitalization, stroke, or myocardial infarction. However, it was associated with increased PPI during hospitalization (8.3 vs 2.8%, P = 0.005) and from discharge to 1 year (4.7 vs. 1.5%, P = 0.01). The ejection fraction failed to improve after TAVR in patients with new LBBB and remained lower at 6 months to 1 year (52.8 vs. 58.1%, P < 0.001). CONCLUSION: Persistent, new-onset LBBB occurred in 10.5% of patients without intraventricular baseline conduction who underwent TAVR in the PARTNER experience. New LBBB was not associated with death, repeat hospitalization, stroke, or myocardial infarction at 1 year, but was associated with a higher rate of PPI and failure of left ventricular ejection fraction to improve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Bloqueio de Ramo/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Prognóstico , Volume Sistólico/fisiologia , Resultado do Tratamento
8.
N Engl J Med ; 364(23): 2187-98, 2011 Jun 09.
Artigo em Inglês | MEDLINE | ID: mdl-21639811

RESUMO

BACKGROUND: The use of transcatheter aortic-valve replacement has been shown to reduce mortality among high-risk patients with aortic stenosis who are not candidates for surgical replacement. However, the two procedures have not been compared in a randomized trial involving high-risk patients who are still candidates for surgical replacement. METHODS: At 25 centers, we randomly assigned 699 high-risk patients with severe aortic stenosis to undergo either transcatheter aortic-valve replacement with a balloon-expandable bovine pericardial valve (either a transfemoral or a transapical approach) or surgical replacement. The primary end point was death from any cause at 1 year. The primary hypothesis was that transcatheter replacement is not inferior to surgical replacement. RESULTS: The rates of death from any cause were 3.4% in the transcatheter group and 6.5% in the surgical group at 30 days (P=0.07) and 24.2% and 26.8%, respectively, at 1 year (P=0.44), a reduction of 2.6 percentage points in the transcatheter group (upper limit of the 95% confidence interval, 3.0 percentage points; predefined margin, 7.5 percentage points; P=0.001 for noninferiority). The rates of major stroke were 3.8% in the transcatheter group and 2.1% in the surgical group at 30 days (P=0.20) and 5.1% and 2.4%, respectively, at 1 year (P=0.07). At 30 days, major vascular complications were significantly more frequent with transcatheter replacement (11.0% vs. 3.2%, P<0.001); adverse events that were more frequent after surgical replacement included major bleeding (9.3% vs. 19.5%, P<0.001) and new-onset atrial fibrillation (8.6% vs. 16.0%, P=0.006). More patients undergoing transcatheter replacement had an improvement in symptoms at 30 days, but by 1 year, there was not a significant between-group difference. CONCLUSIONS: In high-risk patients with severe aortic stenosis, transcatheter and surgical procedures for aortic-valve replacement were associated with similar rates of survival at 1 year, although there were important differences in periprocedural risks. (Funded by Edwards Lifesciences; Clinical Trials.gov number, NCT00530894.).


Assuntos
Estenose da Valva Aórtica/terapia , Valva Aórtica/cirurgia , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/efeitos adversos , Doenças Cardiovasculares/epidemiologia , Doenças Cardiovasculares/mortalidade , Cateterismo , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Análise de Intenção de Tratamento , Masculino , Complicações Pós-Operatórias , Fatores de Risco , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia
9.
Catheter Cardiovasc Interv ; 83(3): 457-64, 2014 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-23703878

RESUMO

OBJECTIVES: To compare iliofemoral arterial complications with transfemoral transcatheter aortic valve replacement (TF-TAVR) utilizing surgical cutdown versus percutaneous access with closure devices in a randomized trial. BACKGROUND: Major vascular complications following TAVR are a significant risk of the procedure. There are no randomized data comparing whether access method in TF-TAVR influences the risk of such complications. METHODS: From June to December 2011, 30 consecutive patients undergoing TF-TAVR were randomized to either surgical cutdown (C) or percutaneous (P) access. Subjects underwent preoperative CT scans, pre- and post-operative bilateral femoral arterial ultrasound and angiography. The primary endpoint was the composite of major and minor vascular complications at 30 days, as defined by the Valve Academic Research Consortium-2. Multivariate predictors of vascular complications were identified. RESULTS: Of the 30 subjects enrolled, 27 were treated with the randomized method of access as randomized. Iliofemoral complications were observed in eight patients (26.7%; C = 4, P = 4), all of which were dissections and/or stenoses that required percutaneous and/or surgical intervention. There were two (13.3%) major and two (13.3%) minor complications in each group. Two covariates that were significantly associated with vascular complications included female sex and baseline femoral arterial velocity on ultrasound. CONCLUSIONS: While surgical cutdown in TF-TAVR is the recommended access for new centers initiating a TAVR program, this small randomized pilot study suggests the lesser invasive percutaneous method in an experienced center is equivalent in safety to the surgical method. Doppler ultrasound may be useful in predicting complications prior to the procedure.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/métodos , Cateterismo Periférico , Artéria Femoral/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Procedimentos Cirúrgicos Vasculares , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico , Velocidade do Fluxo Sanguíneo , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Periférico/efeitos adversos , Feminino , Artéria Femoral/diagnóstico por imagem , Artéria Femoral/fisiopatologia , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Projetos Piloto , Punções , Fluxo Sanguíneo Regional , Fatores de Risco , Fatores Sexuais , Fatores de Tempo , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler , Ultrassonografia de Intervenção , Procedimentos Cirúrgicos Vasculares/efeitos adversos
10.
JTCVS Open ; 17: 55-63, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38420551

RESUMO

Background: The use of rapid-deployment valves (RDVs) has been shown to reduce the operative time for surgical aortic valve replacement (AVR). Long-term core laboratory-adjudicated data are scarce, however. Here we report final 7-year data on RDV use. Methods: TRANSFORM was a prospective, nonrandomized, multicenter, single-arm trial implanting a stented bovine pericardial valve with an incorporated balloon-expandable sealing frame. A prior published 1-year analysis included 839 patients from 29 centers. An additional 46 patients were enrolled and implanted, for a total of 885 patients. Annual clinical and core laboratory-adjudicated echocardiographic outcomes were collected through 8 years. Primary endpoints were structural valve deterioration (SVD), all-cause reintervention, all-cause valve explantation, and all-cause mortality. Secondary endpoints included hemodynamic performance assessed by echocardiography. The mean duration of follow-up was 5.0 ± 2.0 years. Results: The mean patient age was 73.3 ± 8.2 years. Isolated AVR was performed in 62.1% of the patients, and AVR with concomitant procedures was performed in 37.9%. Freedom from all-cause mortality at 7 years was 76.0% for isolated AVR and 68.2% for concomitant AVR. Freedom from SVD, all-cause reintervention, and valve explantation at 7 years was 97.5%, 95.7%, and 97.8%, respectively. The mean gradient and effective orifice area at 7 years were 11.1 ± 5.3 mm Hg and 1.6 ± 0.3 cm2, respectively. Paravalvular leak at 7 years was none/trace in 88.6% and mild in 11.4%. In patients undergoing isolated AVR, the cumulative probability of pacemaker implantation was 13.9% at 30 days, 15.5% at 1 year, and 21.8% at 7 years. Conclusions: AVR for aortic stenosis using an RDV is associated with low rates of late adverse events. This surgical pericardial tissue platform provides excellent and stable hemodynamic performance through 7 years.

11.
J Thorac Cardiovasc Surg ; 163(6): 2046-2052.e2, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-33985812

RESUMO

BACKGROUND: Intermediate- and high-risk patients undergoing isolated surgical aortic valve replacement have superior outcomes at higher-volume compared with lower-volume hospitals. This study examines the impact of hospital volume on outcomes in low-risk patients undergoing aortic valve replacement. METHODS: Using data from our 29 North Texas hospital collaborative, we examined 2066 low-risk cases (Society of Thoracic Surgeons Predicted Risk of Mortality of ≤3%) undergoing aortic valve replacement surgery between January 1, 2012, and December 31, 2017. Cases from 3 high-volume hospitals (≥200 aortic valve replacement cases total) and 26 low-volume hospitals (<200 cases total) were examined. RESULTS: Some 53.5% of the cases were at high-volume hospitals. No statistical differences were seen in the Predicted Risk of Mortality or pertinent demographics between the high-volume and low-volume hospitals. Significant differences in outcomes were seen between the 2 groups in operative mortality (2.28% vs 1.19%, P = .007), renal failure (2.14% vs 1.00%, P = .003), and readmission within 30 days (9.72% vs 6.25%, P < .001) when comparing low-volume with high-volume hospitals. In patients undergoing aortic valve replacement, undergoing the procedure in a low-volume hospital was an independent predictor for operative mortality (odds ratio, 1.95; 95% confidence interval, 1.20-3.20; P = .008) and renal failure (odds ratio, 2.25; 95% confidence interval, 1.33-3.81; P = .003). CONCLUSIONS: Operative mortality in low-risk patients undergoing aortic valve replacement is higher in low-volume compared with high-volume hospitals. The probability of a major complication, such as renal failure, is also greater in low-volume hospitals. The relationship between volume and outcomes in low-risk patients will require more research to understand the causes and design appropriate interventions.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Insuficiência Renal , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Mortalidade Hospitalar , Humanos , Masculino , Fatores de Risco , Substituição da Valva Aórtica Transcateter/métodos , Resultado do Tratamento
12.
Catheter Cardiovasc Interv ; 78(7): 1017-9, 2011 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-21547997

RESUMO

Transcatheter aortic valve implantation (TAVI) was introduced in 2006 as an alternative for surgical aortic valve replacement (SAVR) as treatment for patients with aortic stenosis. Endocarditis after TAVI has been anecdotally reported, but concerns aroused because SAVR is often needed to explant the endocarditic valve in a high risk patient previously deemed not to be a surgical candidate. We report a case of a patient who underwent TAVI because he was too high risk to undergo SAVR. Several months later, he developed an intermittent self-limiting fever of unknown origin which eventually was diagnosed as endocarditis. The valve was surgically removed, and pathology showed an infection caused by Histoplasma capsulatum. The patient recovered fully and remains in good condition.


Assuntos
Estenose da Valva Aórtica/terapia , Cateterismo Cardíaco/efeitos adversos , Endocardite/microbiologia , Artéria Femoral , Implante de Prótese de Valva Cardíaca/efeitos adversos , Próteses Valvulares Cardíacas/efeitos adversos , Histoplasma/isolamento & purificação , Histoplasmose/microbiologia , Infecções Relacionadas à Prótese/microbiologia , Idoso , Antibacterianos/uso terapêutico , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/métodos , Remoção de Dispositivo , Ecocardiografia Transesofagiana , Endocardite/diagnóstico , Endocardite/terapia , Febre de Causa Desconhecida/microbiologia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Histoplasmose/diagnóstico , Histoplasmose/terapia , Humanos , Masculino , Desenho de Prótese , Infecções Relacionadas à Prótese/diagnóstico , Infecções Relacionadas à Prótese/terapia , Resultado do Tratamento
13.
J Heart Valve Dis ; 19(1): 51-8; discussion 59, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20329490

RESUMO

BACKGROUND AND AIM OF THE STUDY: The 30-day outcomes were compared between matched groups of patients undergoing mitral valve procedures through Port Access (femoral cannulation, percutaneous retrograde cardioplegia and aortic occlusion), and through a sternotomy. METHODS: By using a Society of Thoracic Surgeons (STS)-certified, audited database, a total of 1108 patients was identified who were operated on between January 1996 and November 2008. A total of 608 mitral valve repair (MV-Rpr) patients (including 241 with Port Access procedures) and 500 mitral valve replacement (MVR) patients (including 45 with Port Access procedures) was included. Matching groups were created for 177 MV-Rpr patients (matched on preoperative cerebrovascular accident (CVA), previous coronary artery bypass grafting (CABG) and valve procedures, urgent operative status, mitral stenosis, heart failure, NYHA class IV, and age) and for MVR patients with 43 matches (matched for previous CABG surgery, operative status, NYHA class IV, and mitral insufficiency). RESULTS: Patients with Port Access procedures for MV-Rpr had a shorter length of hospital stay (5.4 +/- 2.8 versus 7.3 +/- 5.8 days), less postoperative ventilator usage (8.4 +/- 36.0 versus 24.8 +/- 81.6 h) and a shorter intensive care unit (ICU) stay (34.0 +/- 40.5 versus 81.7 +/- 133.8 h) when compared to sternotomy cases. Port Access also resulted in fewer patients requiring postoperative ventilation (50.3% versus 76.9%; p < 0.001) or reoperation for bleeding (2.3% versus 6.8%; p = 0.048). In MVR patients, Port Access use led to reductions in mortality (11.6% versus 0%; p = 0.021), ventilation time (13.8 +/- 40.3 versus 38.1 +/- 83.0 h), ICU stay (51.9 +/- 83.4 versus 152.4 +/- 125.0 h) and postoperative hospital stay (8.2 +/- 8.0 versus 11.0 +/- 8.6 days). In both groups, the cross-clamp time was longer with Port Access (107.7 +/- 26.8 versus 92.8 +/- 35.2 min for MV-Rpr; 130.2 +/- 44.2 versus 102.7 +/- 64.6 min for MVR). CONCLUSION: The performance of mitral valve surgery through a Port Access approach led to a reduction in ICU time, ventilator time, and hospital stay when compared to sternotomy. No increase in morbidity was observed with Port Access compared to sternotomy.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Valva Mitral/cirurgia , Toracotomia/métodos , Feminino , Humanos , Tempo de Internação , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos , Respiração Artificial/estatística & dados numéricos , Estudos Retrospectivos
14.
Circulation ; 116(11 Suppl): I240-5, 2007 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-17846311

RESUMO

BACKGROUND: To evaluate initial multicenter results with minimally invasive transapical aortic valve implantation (TAP-AVI) for high risk patients with aortic stenosis. METHODS AND RESULTS: TAP-AVI was performed via a small anterolateral minithoracotomy with or without femoro-femoral extracorporeal circulation (ECC) on the beating heart. A pericardial xenograft fixed within a stainless steel, balloon expandable stent (Edwards SAPIEN THV, Edwards Lifesciences) was used. Fifty-nine consecutive patients (81+/-6 years, 44 female) were operated on from 02/06 until 10/06 at 4 centers using fluoroscopic and echocardiographic visualization. Average EuroSCORE predicted risk for mortality was 27+/-14%. TAP valve positioning was performed successfully in 53 patients, 4 required early conversion to sternotomy. Implantation (23-mm valves in 19 and 26-mm valves in 40 patients) was performed on the beating heart during brief periods of rapid ventricular pacing. Thirty-one patients were operated on without cardiopulmonary bypass. Neither coronary artery obstruction nor migration of the prosthesis was observed, and all valves had good hemodynamic function. Echocardiography revealed minor paravalvular leakage in 26 patients (trace in 11, mild in 12, and severe in 3). Eight patients died in-hospital (13.6%) without any valve dysfunction. Actuarial survival was 75.7+/-5.9% at a follow-up interval of 110+/-77 days (range 1 to 255 days). CONCLUSIONS: TAP-AVI can be performed safely with good early results in high risk patients. Long-term valve performance as well as broader based applications of this promising approach will need to be studied.


Assuntos
Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Animais , Valva Aórtica/patologia , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Bovinos , Feminino , Seguimentos , Implante de Prótese de Valva Cardíaca/tendências , Humanos , Masculino , Desenho de Prótese/instrumentação , Desenho de Prótese/métodos , Desenho de Prótese/tendências
15.
Eur J Cardiothorac Surg ; 31(1): 9-15, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17097302

RESUMO

OBJECTIVE: To evaluate the feasibility of minimally invasive transapical beating heart aortic valve implantation (TAP-AVI) for high-risk patients with aortic stenosis. METHODS: TAP-AVI was performed via a small anterolateral minithoracotomy with or without femoral extracorporeal circulation (ECC) on the beating heart. A pericardial xenograft fixed within a stainless steel, balloon expandable stent (Cribier-Edwards, Edwards Lifesciences, Irvine, CA, USA) was used. Thirty consecutive patients (82 +/- 5.1 years, 21 (70%) female) were operated from 02/06 until 09/06 at one center using fluoroscopic and echocardiographic visualization. Average EuroSCORE predicted risk for mortality was 27 +/- 12%. RESULTS: Valve positioning was successful in 29 patients and one required early conversion to full sternotomy. Implantation (8 mm x 23 mm and 22 mm x 26 mm valves) was performed on the beating heart during brief periods of rapid ventricular pacing. ECC was applied in 13 patients. Neither coronary artery obstruction nor migration of the prosthesis was observed and all valves displayed good hemodynamic function. Echocardiography revealed minor paravalvular leakage in 14 patients (trace in three, mild in nine and moderate in two). Three patients (10%) died, one on postoperative day (POD) three secondary to preoperative global myocardial failure and two on POD 18 and 86 due to abdominal complications. CONCLUSIONS: Minimally invasive beating heart TAP-AVI is feasible. Initial results are encouraging in view of the high-risk profile of the patients. Long-term studies as well as randomized protocols are required.


Assuntos
Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Métodos Epidemiológicos , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Procedimentos Cirúrgicos Minimamente Invasivos/métodos , Seleção de Pacientes , Desenho de Prótese , Radiografia , Resultado do Tratamento
16.
J Atr Fibrillation ; 10(1): 1494, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29250217

RESUMO

Atrial fibrillation (AF) is associated with worse outcomes in many cardiovascular diseases. There are few data examining pacemaker implantation rates and indications in patients with AF who undergo transcatheter aortic valve replacement (TAVR). To examine the impact of AF on the incidence of and indications for pacemakers in patients undergoing TAVR, we evaluated data of 1723 patients without pre-existing pacemakers who underwent TAVR in the Placement of AoRTic TraNscathetER Valve (PARTNER) trial. Permanent pacemaker implantation rates and indications were compared in groups based on baseline and discharge heart rhythm: sinus rhythm (SR) vs. AF. 1211 patients manifested SR at baseline/SR at discharge (SR/SR), 105 SR baseline/AF discharge (SR/AF), and 407 AF baseline/AF discharge (AF/AF). Patients who developed and were discharged with AF (SR/AF) had the highest rates of pacemaker implantation at 30 days (13.7% SR/AF vs. 5.4% SR/SR, p=0.0008 and 5.9% AF/AF, p=0.008) and 1 year (17.7% SR/AF vs. 7.1% SR/SR, p=0.0002 and 8.1% AF/AF, p=0.0034). Conversion from SR to AF by discharge was an independent predictor of increased pacemaker implantation at 30 days (HR 2.19 vs. SR/SR, 95% CI 1.23-3.93, p=0.008) and 1 year (HR 1.91 vs. SR/SR, 95% CI 1.33-3.80). Pacemaker indications differed between groups, with relatively more implanted in the AF groups for sick sinus syndrome (SSS) versus AV block. In conclusion, conversion to AF is an independent predictor of permanent pacemaker implantation in TAVR patients. Indications differ depending on heart rhythm, with patients in AF manifesting clinically significant tachy-brady syndrome versus AV block.

17.
J Heart Valve Dis ; 15(1): 108-13; discussion 113-4, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16480021

RESUMO

BACKGROUND AND AIM OF THE STUDY: The Ross procedure employs an autologous pulmonary valve to replace the aortic valve, but requires pulmonary homograft replacement. Concerns regarding long-term homograft function may limit the adoption of this technique. Herein, the incidence of, and factors leading to, stenosis of the homograft were examined. METHODS: Data were collected from 131 patients (32 females, 99 males) who underwent a Ross procedure between July 1994 and December 2003. Complete follow up data were collected from 113 of 125 (90.4%) living patients. Donor valve information, including storage time, was supplied by the graft manufacturers. Data were analyzed using chi-square tests, t-test and logistic regression. RESULTS: The mean patient follow up was 703 +/- 574 days (median 599 days; range: 2 to 2,408 days). Echocardiographic stenosis had occurred in 14 patients (12.4%). Four patients (3.2%) required homograft replacement, and two required balloon valvuloplasty. There was no significant difference in graft vendor, recipient, donor age or blood type match between stenotic and non-stenotic recipients. Donor valve size was appropriate for the recipients, and greater than predicted by recipient body surface area (BSA). Donor valves that developed stenosis had a shorter storage time after processing (160 +/- 100 versus 249 +/- 223 days; p = 0.03). Male donor valves became stenotic in 9.9% (7/71) of male recipients, but in none of 20 females. Female donor valves became stenotic in 27.3% (3/11) of male recipients, and in 28.6% (2/7) females. Logistic regression showed donor gender to be a significant predictor for stenosis (p = 0.007; odds ratio 14.1 for female/male donors; 95% CI 2.1-96.4). CONCLUSION: Donor valves which developed stenosis had a shorter mean cryopreservation time than those that did not develop stenosis. In addition, female donor homografts appeared to develop stenosis at a greater rate, independent of patient age, graft size to BSA match, and blood type.


Assuntos
Implante de Prótese de Valva Cardíaca/efeitos adversos , Estenose da Valva Pulmonar/epidemiologia , Estenose da Valva Pulmonar/etiologia , Adolescente , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/transplante , Distribuição de Qui-Quadrado , Ecocardiografia , Ecocardiografia Doppler em Cores , Feminino , Seguimentos , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/epidemiologia , Doenças das Valvas Cardíacas/cirurgia , Humanos , Incidência , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Valor Preditivo dos Testes , Valva Pulmonar/diagnóstico por imagem , Valva Pulmonar/transplante , Estenose da Valva Pulmonar/diagnóstico por imagem , Reoperação , Fatores Sexuais , Transplante Homólogo , Resultado do Tratamento
18.
Eur J Cardiothorac Surg ; 29(5): 703-8, 2006 May.
Artigo em Inglês | MEDLINE | ID: mdl-16600616

RESUMO

OBJECTIVE: Percutaneous aortic valve implantation has been performed in patients with severe aortic stenosis judged as nonsurgical candidates. We evaluated a facilitated transapical antegrade approach for potential use in surgical high-risk patients. METHODS: A pericardial xenograft fixed within a 23-mm stent (Cribier-Edwards aortic prosthesis, Edwards Inc., Irvine, CA, USA) was implanted using a transapical approach in fifteen 35-45 kg pigs. A limited or a full sternotomy was used to transapically introduce a crimped valve through a 24-F sheath. Deployments were performed on the beating heart either with ventricular unloading using femoro-femoral cardiopulmonary bypass (CPB) or rapid ventricular pacing (RVP), all under fluoroscopic and echocardiographic visualization. RESULTS: All valves were successfully deployed at the target site with acceptable visualization of the noncalcified annulus. Valve migration occurred in six procedures (three distal and three retrograde) secondary to inadequate reduction of ventricular output, unfavorable annular anatomy, excessive crimping of the valve, and dislodgement by the delivery balloon. Exact positioning of the valve into the target area was confirmed by autopsy at the end of the procedures. Paravalvular leak was noted in five implants. CONCLUSIONS: The transapical approach provides a safe, accurate, and effective route for facilitated antegrade delivery of a stent-fixed valve. Advanced stent design will lead to better stability of the implant and may minimize the risk of paravalvular leakage in future. Identifying the appropriate population for human feasibility trials remains a challenge.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Stents , Animais , Modelos Animais de Doenças , Fluoroscopia , Próteses Valvulares Cardíacas , Desenho de Prótese , Suínos , Transplante Heterólogo
19.
Circ Cardiovasc Interv ; 9(1): e002766, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26733582

RESUMO

BACKGROUND: This study sought to evaluate the impact of atrial fibrillation (AF) on clinical outcomes in patients undergoing transcatheter aortic valve replacement. METHODS AND RESULTS: Data were evaluated in 1879 patients with baseline and discharge ECGs who underwent transcatheter aortic valve replacement in the Placement of AoRTic TraNscathetER Valve (PARTNER) trial. A total of 1262 patients manifested sinus rhythm (SR) at baseline/SR at discharge, 113 SR baseline/AF discharge, and 470 AF baseline/AF discharge. Patients who converted from SR to AF by discharge had the highest rates of all-cause mortality at 30 days (P<0.0001 across all groups; 14.2% SR/AF versus 2.6% SR/SR; adjusted hazard ratio [HR]=3.41; P=0.0002) and over 2-fold difference at 1 year (P<0.0001 across all groups; 35.7% SR/AF versus 15.8% SR/SR; adjusted HR=2.14; P<0.0001). The presence of AF on baseline or discharge ECG was a predictor of 1-year mortality (adjusted HR=2.14 for SR/AF group and HR=1.88 for AF/AF groups; P<0.0001 for both groups versus SR/SR). For patients discharged in AF, those with lower ventricular response (ie, <90 bpm) experienced less 1-year all-cause mortality (HR=0.74; P=0.04). CONCLUSIONS: After transcatheter aortic valve replacement, the presence of AF at discharge, and particularly, the conversion to AF by discharge and higher ventricular response are associated with increased mortality. These data underscore the deleterious impact of AF, as well as the need for targeted interventions to improve clinical outcomes, in patients undergoing transcatheter aortic valve replacement. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00530894.


Assuntos
Fibrilação Atrial/cirurgia , Próteses Valvulares Cardíacas , Complicações Pós-Operatórias/epidemiologia , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Fibrilação Atrial/mortalidade , Colúmbia Britânica/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Modelos de Riscos Proporcionais , Índice de Gravidade de Doença , Taxa de Sobrevida/tendências , Fatores de Tempo , Resultado do Tratamento , Estados Unidos/epidemiologia
20.
J Thorac Cardiovasc Surg ; 129(6): 1309-17, 2005 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-15942571

RESUMO

OBJECTIVES: Quality assessment of coronary artery bypass grafting has traditionally been performed with data from clinical databases. Administrative databases that rely primarily on information collected for billing purposes increasingly have been used as tools for public reporting of outcomes quality. The correlation of administrative data with clinical data for clinical quality assessment has not been confirmed. METHODS: With data from a clinical database, we analyzed the outcomes of all patients who underwent coronary artery bypass grafting surgery in 1 hospital between 1999 and 2001. This information was collected before, during, and after the surgery and hospitalization by designated clinical individuals involved with the patient's care and then entered into an audited clinical database (The Society of Thoracic Surgeons National Cardiac Database). These data were then compared with administrative data collected on the same cohort of patients for the number of procedures performed and mortality rate as reported by the federal government (Medical Provider Analysis and Review), state government (Texas Health Care Information Council), hospital system (HCA, Inc, Casemix Database), and an internet Web site (healthgrades.com). Data were analyzed on the basis of the population reported, definitions used, risk assessment algorithms, and case volumes. RESULTS: By using the audited The Society of Thoracic Surgeons database as the standard and aggregating the reporting of case volumes by the inclusion criteria of various sources of administrative data, we found variances in the reported procedure volumes and mortality. Case volumes were overreported by as much as 21% in all patients and underreported by up to 16% or more in Medicare patients. Mortality in administrative data exceeded that reported in clinical data by 21%. Reasons for variances included time period reported (calendar vs fiscal year), population reported (all patients, Medicare patients, Medicare patients aged >/= 65 years), date used for the patient record captured (date of surgery, discharge), and the definition of mortality. Different proprietary risk-adjusting algorithms used magnified variances with risk-adjusted mortality exceeding the Society of Thoracic Surgeons data by as much as 61%. CONCLUSIONS: Substantial variability of reported outcomes is seen in administrative data sets compared with an audited clinical database in the end points of the number of procedures performed and mortality. This variability makes it challenging for the nonclinician unfamiliar with outcomes analysis to make an informed decision.


Assuntos
Ponte de Artéria Coronária , Bases de Dados Factuais , Avaliação de Resultados em Cuidados de Saúde/normas , Idoso , Humanos , Estados Unidos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA