Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 638
Filtrar
1.
Circulation ; 150(15): 1174-1186, 2024 Oct 08.
Artigo em Inglês | MEDLINE | ID: mdl-39258362

RESUMO

BACKGROUND: Evidence from clinical trials of early pulsed field ablation (PFA) systems in treating atrial fibrillation has demonstrated their promising potential to reduce complications associated with conventional thermal modalities while maintaining efficacy. However, the lack of a fully integrated mapping system, a staple technology of most modern electrophysiology procedures, poses limitations in lesion creation and workflow options. A novel variable-loop PFA catheter integrated with an electroanatomic mapping system has been developed that allows for real-time nonfluoroscopic procedural guidance and lesion indexing as well as feedback of tissue-to-catheter proximity. AdmIRE (Assessment of Safety and Effectiveness in Treatment Management of Atrial Fibrillation With the Bosense-Webster Irreversible Electroporation Ablation System), a multicenter, single-arm, Food and Drug Administration investigational device exemption study, evaluated the long-term safety and effectiveness of this integrated PFA system in a large United States-based drug-refractory symptomatic paroxysmal atrial fibrillation patient population. METHODS: Using the PFA catheter with a compatible electroanatomic mapping system, patients with drug-refractory symptomatic paroxysmal atrial fibrillation underwent pulmonary vein isolation. The primary safety end point was primary adverse event within 7 days of ablation. The primary effectiveness end point was a composite end point that included 12-month freedom from documented atrial tachyarrhythmia (ie, atrial fibrillation, atrial tachycardia, atrial flutter) episodes, failure to achieve pulmonary vein isolation, use of a nonstudy catheter for pulmonary vein isolation, repeat procedure (except for one redo during blanking), taking a new or previously failed class I or III antiarrhythmic drug at higher dose after blanking, or direct current cardioversion after blanking. RESULTS: At 30 centers, 277 patients with paroxysmal atrial fibrillation (61.5±10.3 years of age; 64.3% male) in the pivotal cohort underwent PFA. More than 25% of the procedures were performed without fluoroscopy. Median (Q1, Q3) pulmonary vein isolation procedure, fluoroscopy, and transpired PFA application times were 81.0 (61.0, 112.0), 7.1 (0.00, 14.3), and 31.0 (24.8, 40.9) minutes, respectively. The primary adverse event rate was 2.9% (8 of 272), with the most common complication being pericardial tamponade. The 12-month primary effectiveness end point was 74.6%. The 1-year freedom from atrial fibrillation, atrial tachycardia, or atrial flutter recurrence rate after blanking was 75.4%. Substantial improvements in quality of life were observed as early as 3 months after the procedure, concurrent with a reduction in multiple health care use measures. CONCLUSIONS: AdmIRE confirmed the safety and effectiveness of the variable-loop PFA catheter, with short procedure and PFA application times and low fluoroscopy exposure. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT05293639.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Fibrilação Atrial/cirurgia , Fibrilação Atrial/terapia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Ablação por Cateter/métodos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Idoso , Resultado do Tratamento , Veias Pulmonares/cirurgia
2.
J Cardiovasc Electrophysiol ; 35(7): 1422-1428, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38751010

RESUMO

INTRODUCTION: Both atrial fibrillation (AF) and amyloidosis increase stroke risk. We evaluated the best anticoagulation strategy in AF patients with coexistent amyloidosis. METHODS: Consecutive AF patients with concomitant amyloidosis were divided into two groups based on the postablation stroke-prophylaxis approach; group 1: left atrial appendage occlusion (LAAO) in eligible patients and group 2: oral anticoagulation (OAC). Group 1 patients were further divided into Gr. 1A: LAAO + half-does NOAC (HD-NOAC) for 6 months followed by aspirin 81 mg/day and Gr. 1B: LAAO + HD-NOAC. In group 1 patients, with complete occlusion at the 45-day transesophageal echocardiogram, patients were switched to aspirin, 81 mg/day at 6 months. In case of leak, or dense "smoke" in the left atrium (LA) or enlarged LA, they were placed on long-term half-dose (HD) NOAC. Group 2 patients remained on full-dose NOAC during the whole study period. RESULTS: A total of 92 patients were included in the analysis; group 1: 56 and group 2: 36. After the 45-day TEE, 31 patients from group 1 remained on baby-aspirin and 25 on HD NOAC. At 1-year follow-up, four stroke, one TIA and six device-thrombus were reported in group 1A, compared to none in patients in group 1B (5/31 vs. 0/25, p = .03). No bleeding events were reported in group 1, whereas group 2 had five bleeding events (one subdural hematoma, one retinal hemorrhage, and four GI bleedings). Additionally, one stroke was reported in group 2 that happened during brief discontinuation of OAC. CONCLUSION: In patients with coexistent AF and amyloidosis, half-dose NOAC following LAAO was observed to be the safest stroke-prophylaxis strategy.


Assuntos
Amiloidose , Anticoagulantes , Apêndice Atrial , Fibrilação Atrial , Ablação por Cateter , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Masculino , Feminino , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/fisiopatologia , Apêndice Atrial/cirurgia , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Acidente Vascular Cerebral/prevenção & controle , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/diagnóstico , Ablação por Cateter/efeitos adversos , Anticoagulantes/administração & dosagem , Anticoagulantes/efeitos adversos , Fatores de Risco , Fatores de Tempo , Amiloidose/complicações , Amiloidose/diagnóstico , Amiloidose/diagnóstico por imagem , Hemorragia/induzido quimicamente , Administração Oral , Estudos Retrospectivos , Medição de Risco , Aspirina/administração & dosagem , Aspirina/efeitos adversos , Esquema de Medicação , Cardiomiopatias/diagnóstico por imagem , Cardiomiopatias/complicações , Cardiomiopatias/diagnóstico
3.
Europace ; 26(2)2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38266130

RESUMO

AIMS: Different disease processes can combine to cause atrial fibrillation (AF). Their contribution to recurrent AF after ablation in patients is not known. Cardiovascular processes associated with recurrent AF after AF ablation were determined by quantifying biomolecules related to inflammation, metabolism, proliferation, fibrosis, shear stress, atrial pressure, and others in the AXAFA biomolecule study. METHODS AND RESULTS: Twelve circulating cardiovascular biomolecules (ANGPT2, BMP10, CA125, hsCRP, ESM1, FABP3, FGF23, GDF15, IGFBP7, IL6, NT-proBNP, and hsTnT) were quantified in plasma samples obtained prior to a first AF ablation using high-throughput, high-precision assays. Cox regression was used to identify biomolecules associated with recurrent AF during the first 3 months after AF ablation. In 433 patients (64 years [58, 70]; 33% women), baseline concentrations of ANGPT2, BMP10, hsCRP, FGF23, FABP3, GDF15, and NT-proBNP were elevated in patients with recurrent AF (120/433; 28%). After adjustment for 11 clinical features and randomized treatment, elevated NT-proBNP [hazard ratio (HR) 1.58, 95% confidence interval (1.29, 1.94)], ANGPT2 [HR 1.37, (1.12, 1.67)], and BMP10 [HR 1.24 (1.02, 1.51)] remained associated with recurrent AF. Concentrations of ANGPT2, BMP10, and NT-proBNP decreased in patients who remained arrhythmia free, but not in patients with recurrent AF, highlighting their connection to AF. The other eight biomarkers showed unchanged concentrations. CONCLUSION: Elevated concentrations of ANGPT2, BMP10, and NT-proBNP are associated with recurrent AF after a first AF ablation, suggesting that processes linked to disturbed cardiomyocyte metabolism, altered atrial shear stress, and increased load contribute to AF after AF ablation in patients.


Assuntos
Fibrilação Atrial , Humanos , Feminino , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Proteína C-Reativa , Átrios do Coração , Peptídeo Natriurético Encefálico , Biomarcadores , Modelos de Riscos Proporcionais , Fragmentos de Peptídeos , Proteínas Morfogenéticas Ósseas
4.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38696701

RESUMO

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica , Pontuação de Propensão , Sistema de Registros , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Fatores Sexuais , Cardioversão Elétrica/instrumentação , Cardioversão Elétrica/efeitos adversos , Fatores de Risco , Resultado do Tratamento , Arritmias Cardíacas/terapia , Medição de Risco , Europa (Continente) , Fatores de Tempo , Morte Súbita Cardíaca/prevenção & controle
5.
Europace ; 26(9)2024 Aug 30.
Artigo em Inglês | MEDLINE | ID: mdl-39150065

RESUMO

AIMS: Pulsed-field ablation (PFA) is a novel, myocardial-selective, non-thermal ablation modality used to target cardiac arrhythmias. Although prompt electrogram (EGM) signal disappearance is observed immediately after PFA application in the pulmonary veins, whether this finding results in adequate transmural lesions is unknown. The aim of this study is to check whether application repetition and catheter-tissue contact impact lesion formation during PFA. METHODS AND RESULTS: A circular loop PFA catheter was used to deliver repeated energy applications with various levels of contact force. A benchtop vegetal potato model and a beating heart ventricular myocardial model were utilized to evaluate the impact of application repetition, contact force, and catheter repositioning on contiguity and lesion depth. Lesion development occurred over 18 h in the vegetal model and over 6 h in the porcine model. Lesion formation was found to be dependent on application repetition and contact. In porcine ventricles, single and multiple stacked applications led to a lesion depth of 3.5 ± 0.7 and 4.4 ± 1.3 mm, respectively (P = 0.002). Furthermore, the greater the catheter-tissue contact, the more contiguous and deeper the lesions in the vegetal model (1.0 ± 0.9 mm with no contact vs. 5.4 ± 1.4 mm with 30 g of force; P = 0.0001). CONCLUSION: Pulsed-field ablation delivered via a circular catheter showed that both repetition and catheter contact led independently to deeper lesion formation. These findings indicate that endpoints for effective PFA are related more to PFA biophysics than to mere EGM attenuation.


Assuntos
Cateteres Cardíacos , Ablação por Cateter , Desenho de Equipamento , Ablação por Cateter/métodos , Ablação por Cateter/instrumentação , Animais , Suínos , Ventrículos do Coração/fisiopatologia , Ventrículos do Coração/cirurgia , Modelos Animais , Sus scrofa , Fatores de Tempo
6.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584394

RESUMO

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Assuntos
Ablação por Cateter , Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Arritmias Cardíacas/etiologia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cardioversão Elétrica/efeitos adversos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
7.
Europace ; 26(8)2024 Aug 03.
Artigo em Inglês | MEDLINE | ID: mdl-39082698

RESUMO

Cardioneuroablation has emerged as a potential alternative to cardiac pacing in selected cases with vasovagal reflex syncope, extrinsic vagally induced sinus bradycardia-arrest or atrioventricular block. The technique was first introduced decades ago, and its use has risen over the past decade. However, as with any intervention, proper patient selection and technique are a prerequisite for a safe and effective use of cardioneuroablation therapy. This document aims to review and interpret available scientific evidence and provide a summary position on the topic.


Assuntos
Bradicardia , Síncope Vasovagal , Humanos , Bradicardia/terapia , Bradicardia/fisiopatologia , Bradicardia/cirurgia , Bradicardia/diagnóstico , Síncope Vasovagal/cirurgia , Síncope Vasovagal/diagnóstico , Síncope Vasovagal/fisiopatologia , Resultado do Tratamento , Ablação por Cateter/métodos , Consenso , Frequência Cardíaca , Técnicas de Ablação
8.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38584423

RESUMO

Electrical storm (ES) is a state of electrical instability, manifesting as recurrent ventricular arrhythmias (VAs) over a short period of time (three or more episodes of sustained VA within 24 h, separated by at least 5 min, requiring termination by an intervention). The clinical presentation can vary, but ES is usually a cardiac emergency. Electrical storm mainly affects patients with structural or primary electrical heart disease, often with an implantable cardioverter-defibrillator (ICD). Management of ES requires a multi-faceted approach and the involvement of multi-disciplinary teams, but despite advanced treatment and often invasive procedures, it is associated with high morbidity and mortality. With an ageing population, longer survival of heart failure patients, and an increasing number of patients with ICD, the incidence of ES is expected to increase. This European Heart Rhythm Association clinical consensus statement focuses on pathophysiology, clinical presentation, diagnostic evaluation, and acute and long-term management of patients presenting with ES or clustered VA.


Assuntos
Desfibriladores Implantáveis , Insuficiência Cardíaca , Taquicardia Ventricular , Humanos , Fatores de Risco , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Incidência , Insuficiência Cardíaca/complicações , Ásia/epidemiologia , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/terapia , Taquicardia Ventricular/complicações
9.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38587017

RESUMO

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , América Latina , Resultado do Tratamento , Catéteres , Ásia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos
10.
Pacing Clin Electrophysiol ; 47(2): 185-194, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38010836

RESUMO

BACKGROUND: Despite its clinical benefits, patient compliance to remote monitoring (RM) of cardiac implantable electronic devices (CIEDs) varies and remains under-studied in diverse populations. OBJECTIVE: We sought to evaluate RM compliance, clinical outcomes, and identify demographic and socioeconomic factors affecting RM in a diverse urban population in New York. METHODS: This retrospective cohort study included patients enrolled in CIED RM at Montefiore Medical Center between December 2017 and May 2022. RM compliance was defined as the percentage of days compliant to RM transmission divided by the total prescribed days of RM. Patients were censored when they were lost to follow-up or at the time of death. The cohorts were categorized into low (≤30%), intermediate (31-69%), and high (≥70%) RM compliance groups. Statistical analyses were conducted accordingly. RESULTS: Among 853 patients, median RM compliance was 55%. Age inversely affected compliance (p < .001), and high compliance was associated with guideline-directed medical therapy (GDMT) usage and implantable cardioverter defibrillator (ICD)/cardiac resynchronization defibrillator (CRTD) devices. The low-compliance group had a higher mortality rate and fewer regular clinic visits (p < .001) than high-compliance group. Socioeconomic factors did not significantly impact compliance, while Asians showed higher compliance compared with Whites (OR 3.67; 95% CI 1.08-12.43; p = .04). Technical issues were the main reason for non-compliance. CONCLUSION: We observed suboptimal compliance to RM, which occurred most frequently in older patients. Clinic visit compliance, optimal medical therapy, and lower mortality were associated with higher compliance, whereas insufficient understanding of RM usage was the chief barrier to compliance.


Assuntos
Desfibriladores Implantáveis , Tecnologia de Sensoriamento Remoto , Humanos , Idoso , Estudos Retrospectivos , Dispositivos de Terapia de Ressincronização Cardíaca , Demografia
11.
Circulation ; 145(12): 906-915, 2022 03 22.
Artigo em Inglês | MEDLINE | ID: mdl-35135308

RESUMO

BACKGROUND: We aimed to assess the prevalence of ischemic brain lesions detected by magnetic resonance imaging and their association with cognitive function 3 months after first-time ablation using continuous oral anticoagulation in patients with paroxysmal atrial fibrillation (AF). METHODS: We performed a prespecified analysis of the AXAFA-AFNET 5 trial (Anticoagulation Using the Direct Factor Xa Inhibitor Apixaban During Atrial Fibrillation Catheter Ablation: Comparison to Vitamin K Antagonist Therapy), which randomized 674 patients with AF 1:1 to uninterrupted apixaban or vitamin K antagonist therapy before first-time ablation. Brain magnetic resonance imaging using fluid-attenuated inversion recovery and high-resolution diffusion-weighted imaging was obtained within 3 to 48 hours after AF ablation in all eligible patients enrolled in 25 study centers in Europe and the United States. Patients underwent cognitive assessment 3 to 6 weeks before ablation and 3 months after ablation using the Montreal Cognitive Assessment (MoCA). RESULTS: In 84 (26.1%) of 321 patients with analyzable magnetic resonance imaging, high-resolution diffusion-weighted imaging detected at least 1 acute brain lesion, including 44 (27.2%) patients treated with apixaban and 40 (24.8%) patients treated with vitamin K antagonist (P=0.675). Median MoCA score was similar in patients with or without acute brain lesions at 3 months after ablation (28 [interquartile range (IQR), 26-29] versus 28 [IQR, 26-29]; P=0.948). Cerebral chronic white matter damage (defined as Wahlund score ≥4 points) detected by fluid-attenuated inversion recovery was present in 130 (40.5%) patients and associated with lower median MoCA scores before ablation (27 [IQR, 24-28] versus 27 [IQR, 25-29]; P=0.026) and 3 months after ablation (27 [IQR, 25-29] versus 28 [IQR, 26-29]; P=0.011). This association was no longer significant when adjusted for age and sex. Age was associated with lower MoCA scores before ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]) and 3 months after ablation (relative risk, 1.02 per 10 years [95% CI, 1.01-1.03]). CONCLUSIONS: Chronic white matter damage as well as acute ischemic lesions detected by brain magnetic resonance imaging were found frequently after first-time ablation for paroxysmal AF using uninterrupted oral anticoagulation. Acute ischemic brain lesions detected by high-resolution diffusion-weighted imaging were not associated with cognitive function at 3 months after ablation. Lower MoCA scores before and after ablation were associated only with older age, highlighting the safety of AF ablation on uninterrupted oral anticoagulation. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT02227550.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Anticoagulantes/uso terapêutico , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/cirurgia , Encéfalo/diagnóstico por imagem , Ablação por Cateter/efeitos adversos , Cognição , Humanos , Imageamento por Ressonância Magnética , Resultado do Tratamento , Vitamina K
12.
J Cardiovasc Electrophysiol ; 34(12): 2621-2625, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37987539

RESUMO

INTRODUCTION: Catheter ablation of atrial fibrillation (AF) has emerged as the most effective therapy. However, rare anatomical abnormalities such as situs inversus totalis, dextrocardia, or interrupted inferior vena cava can make ablation challenging. METHODS AND RESULTS: We report a case of a 55-year-old woman with situs inversus totalis, dextrocardia, surgical atrial septal defect repair, left-sided dual chamber pacemaker in place, and symptomatic recurrent persistent AF who underwent successful pulmonary vein and posterior wall isolation by the superior access from the left internal jugular vein. CONCLUSIONS: It is a feasible and safe approach with support of transesophageal echocardiography and multiple emerging technologies.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Dextrocardia , Cardiopatias Congênitas , Situs Inversus , Feminino , Humanos , Pessoa de Meia-Idade , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/diagnóstico por imagem , Situs Inversus/complicações , Situs Inversus/diagnóstico por imagem , Situs Inversus/cirurgia , Veia Cava Inferior/diagnóstico por imagem , Veia Cava Inferior/cirurgia , Dextrocardia/complicações , Dextrocardia/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia
13.
J Cardiovasc Electrophysiol ; 34(2): 327-334, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36511480

RESUMO

INTRODUCTION: Electrical isolation of pulmonary veins (PVI) is a cornerstone for atrial fibrillation (AF) ablation. The overall effect of AF ablation, and especially lesions beyond PVI, on left atrial (LA) function is currently poorly understood. Our aim was to determine if LA function is different in patients after extensive LA ablation compared to PVI only. We performed non-inferiority analysis of LA function after PVI with additional nonpulmonary vein ablation lesions in LA (PVI+) and PVI alone. METHODS: We studied 68 patients consecutive patients who underwent AF ablation and who had complete transthoracic echocardiogram (TTE) within 12 months before AF ablation and 1-12 months after the procedure. Patients were stratified into two groups: PVI only and PVI+. Primary outcome was change in LA reservoir strain (LASr). Noninferiority margin was defined at 6%. RESULTS: The PVI only group had a higher proportion of patients with paroxysmal AF (70% vs. 30%). The PVI+ group was observed to have a slightly higher increase in LASr compared to PVI alone (5.0% vs. 4.3%, p < .01 for noninferiority). LASr noninferiority was confirmed when adjusted for age, sex, coronary artery disease, hyperlipidemia, and AF type, rhythm at preprocedure TTE in a multivariable linear regression model, 90% CI (-5.46 to 2.04), p < .01. CONCLUSION: LA functional improvement evaluated by LASr was noninferior after PVI with additional LA ablation lesions compared to PVI alone. These findings were confirmed when adjusted for confounding clinical variables, suggesting that more extensive ablation does not negatively affect LA function.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Átrios do Coração/diagnóstico por imagem , Átrios do Coração/cirurgia , Função do Átrio Esquerdo , Resultado do Tratamento , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
14.
J Cardiovasc Electrophysiol ; 34(12): 2493-2503, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37870157

RESUMO

INTRODUCTION: The prospective, nonrandomized, multicenter Q-FFICIENCY study demonstrated the safety and 12-month efficacy of paroxysmal atrial fibrillation (AF) ablation with the novel QDOT MICRO temperature-controlled, contact force-sensing, radiofrequency (RF) catheter. Participants underwent pulmonary vein isolation with very high-power short-duration (vHPSD) mode (90 W, ≤4 s) alone or combined with conventional-power temperature-controlled (CPTC) mode (25-50 W). This study aimed to assess quality-of-life (QOL) and healthcare utilization (HCU) benefits experienced by Q-FFICIENCY study participants. METHODS: Besides evaluating procedural efficiency, QOL and HCU were assessed through 12 months postablation via Atrial Fibrillation Effect on Quality-of-Life Tool (AFEQT) score, antiarrhythmic drug (AAD) use, and incidence of cardioversion and cardiovascular hospitalization. RESULTS: Of 191 participants enrolled, 166 were ablated with the new catheter. Compared to baseline, statistically significant, clinically meaningful improvements in composite and subcategories of AFEQT scores were observed at 3 months and sustained through 12 months (12-month increase, 29.3-44.2 points). Class I/III AAD use decreased from 97.6% (162/166) at baseline to 19.6% (31/158) during Months 6-12, representing a significant 79.9% reduction. The cardioversion rate significantly declined by 93.9% from 31.3% (12 months preablation) to 1.9% (evaluation period). One-year Kaplan-Meier estimates of freedom from all-cause and cardiovascular hospitalization were 80.9% (95% confidence interval [CI], 74.8%-86.9%) and 88.8% (95% CI, 84.0%-93.7%), respectively. CONCLUSIONS: Paroxysmal AF ablation with the novel temperature-controlled RF catheter in vHPSD mode, alone or with CPTC mode, led to clinically meaningful improvement in QOL and significant reduction in AAD use, cardioversion, and cardiovascular hospitalization.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/tratamento farmacológico , Estudos Prospectivos , Qualidade de Vida , Temperatura , Resultado do Tratamento , Catéteres , Antiarrítmicos/uso terapêutico , Veias Pulmonares/cirurgia , Aceitação pelo Paciente de Cuidados de Saúde , Ablação por Cateter/efeitos adversos
15.
J Cardiovasc Electrophysiol ; 34(4): 1024-1032, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36786513

RESUMO

INTRODUCTION: Capsulectomy is recommended in patients with cardiac implantable electronic device (CIED) infection after transvenous lead extraction (TLE) but is time-consuming and requires extensive tissue debridement. In this study, we describe the outcomes of chlorhexidine gluconate (CHG) lavage in lieu of capsulectomy for the treatment of CIED infections. METHODS: This retrospective study included patients who underwent TLE for CIED-related infections in two institutions in Colombia. In the capsulectomy group, complete capsulectomy was performed after hardware removal. In the CHG group, exhaustive lavage of the generator pocket with 20 cc of CHG at 2% followed by irrigation with approximately 500 cc of normal saline (0.9% sodium chloride) was performed. The primary outcomes included reinfection and hematoma formation in the generator pocket. Secondary outcomes included the occurrence of any adverse reaction to chlorhexidine, the need for reintervention, infection-related mortality, and total procedural time. RESULTS: A total of 102 patients (mean age 67.2 ± 13 years, 32.4% female) underwent CIED extraction with either total capsulectomy (n = 54) or CHG (n = 48) lavage. Hematoma formation was significantly higher in the capsulectomy group versus the CHG group (13% vs. 0%, p = .014), with no significant differences in the reinfection rate. Capsulectomy was associated with longer procedural time (133.7 ± 78.5 vs. 89.9 ± 51.8 min, p = .002). No adverse reactions to CHG were found. Four patients (4.3%) died from worsening sepsis: three in the capsulectomy group and one in the CHG group (p = .346). CONCLUSIONS: In patients with CIED infections, the use of CHG without capsulectomy resulted in a lower risk of hematoma formation and shorter procedural times without an increased risk of reinfection or adverse events associated with CHG use.


Assuntos
Cardiopatias , Marca-Passo Artificial , Humanos , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Masculino , Clorexidina , Marca-Passo Artificial/efeitos adversos , Estudos Retrospectivos , Irrigação Terapêutica , Reinfecção/etiologia , Cardiopatias/etiologia
16.
J Cardiovasc Electrophysiol ; 34(12): 2527-2534, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37746923

RESUMO

INTRODUCTION: Earlier studies have shown a clear association between severity of human immunodeficiency virus (HIV) infection and incident atrial fibrillation (AF). We present the long-term outcome of catheter ablation (CA) and electrophysiological characteristics in HIV+ AF patients. METHODS: This study evaluated 1438 consecutive AF patients [31 (2.15%) with HIV and 1407 (97.8%) without HIV diagnosis] undergoing their first CA at our center. A total of 31 HIV patients and 31 controls were generated by propensity matching, based on calculated risk factor scores, using a logistic model. During first procedure, all received isolation of pulmonary vein (PV) + posterior wall and superior vena cava. Non-PV triggers, defined as ectopic triggers originating from sites other than PVs, were identified at the redo ablation with high-dose isoproterenol challenge. RESULTS: Clinical characteristics were not different between the groups. When compared to the control, by the end of 5 years after the first procedure, recurrence was significantly greater in HIV group [100% vs. 54%, p < .001]. Among patients that underwent redo ablation non-PV triggers were higher in HIV group [93.5% vs. 54%, p < .001], and most frequently originated from the coronary sinus [67.7% vs. 45.2%, p < .001] and left atrial appendage [41.9% vs. 25.8%, p < .001]. After focal ablation of non-PV trigger, no difference in arrhythmia recurrence between two groups [80.6% vs. 87.1%, p = .753] at 1-year follow up was found. CONCLUSION: Our findings suggest that non-PV triggers are highly prevalent in HIV+ AF patients resulting in higher rate of the mid- and long-term arrhythmia recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Infecções por HIV , Veias Pulmonares , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Infecções por HIV/complicações , Infecções por HIV/diagnóstico , Veia Cava Superior , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Veias Pulmonares/cirurgia , Recidiva
17.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378783

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Prevalência , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos
18.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37078691

RESUMO

AIMS: Prevalent atrial fibrillation (AF) is associated with excess cardiovascular (CV) death (D) and hospitalizations (H) in heart failure (HF) with preserved ejection fraction (pEF). We evaluated if it had an independent role in excess CVD in HFpEF and studied its impact on cause-specific mortality and HF morbidity. METHODS AND RESULTS: We used propensity score-matched (PSM) cohorts from the TOPCAT Americas trial to account for confounding by other co-morbidities. Two prevalent AF presentations at study entry were compared: (i) subjects with Any AF event by history or on electrocardiogram (ECG) with PSM subjects without an AF event and (ii) subjects in AF on ECG with PSM subjects in sinus rhythm. We analyzed cause-specific modes of death and HF morbidity during a mean follow-up period of 2.9 years. A total of 584 subjects with Any AF event and 418 subjects in AF on ECG were matched. Any AF was associated with increased CVH [hazard ratio (HR) 1.33, 95% confidence interval (CI) 1.11-1.61, P = 0.003], HFH (HR 1.44, 95% CI 1.12-1.86, P = 0.004), pump failure death (PFD) (HR 1.95, 95% CI 1.05-3.62, P = 0.035), and HF progression from New York Heart Association (NYHA) classes I/II to III/IV (HR 1.30, 95% CI 1.04-1.62, P = 0.02). Atrial fibrillation on ECG was associated with increased risk of CVD (HR 1.46, 95% CI 1.02-2.09, P = 0.039), PFD (HR 2.21, 95% CI 1.11-4.40, P = 0.024), and CVH and HFH (HR 1.37, 95% CI 1.09-1.72, P = 0.006 and HR 1.65, 95% CI 1.22-2.23, P = 0.001, respectively). Atrial fibrillation was not associated with risk of sudden death. Both Any AF and AF on ECG cohorts were associated with PFD in NYHA class III/IV HF. CONCLUSION: Prevalent AF can be an independent risk factor for adverse CV outcomes by its selective association with worsening HF, HFH, and PFD in HFpEF. Prevalent AF was not associated with excess sudden death risk in HFpEF. Atrial fibrillation was also associated with HF progression in early symptomatic HFpEF and PFD in advanced HFpEF. TRIAL REGISTRATION: TOPCAT trial is registered at www.clinicaltrials.gov:identifier NCT00094302.


Assuntos
Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fibrilação Atrial/epidemiologia , Volume Sistólico/fisiologia , Pontuação de Propensão , Comorbidade , Prognóstico
19.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37503957

RESUMO

AIMS: Left atrial appendage occlusion (LAAO) with WATCHMAN device is being used for patients with atrial fibrillation (AFB) and, as an off-label use, atrial flutter (AFL) who can't comply with long-term anticoagulation. We aim to study the differences in outcomes between sexes in patients undergoing Watchman device implantation. METHODOLOGY: The National Inpatient Sample was queried between 2016 and 2019 using ICD-10 clinical modification codes I48x for AFB and AFL. Patients who underwent LAAO were identified using the procedural code 02L73DK. Comorbidities and complications were identified using ICD procedure and diagnosis codes. Differences in primary outcomes were analyzed using multivariable regression and propensity score matching. RESULTS: 38 105 admissions were identified, of which 16 795 (44%) were females (76 ± 7.6 years) and 21 310 (56%) were males (75 ± 8 years). Females were more likely to have cardiac (frequencies: 5.8% vs 3.75%, aOR: 1.5 [1.35-1.68], p1 day inpatient (1.79 [1.67-1.93], P < 0.01) and be discharged to a facility (1.54 [1.33-1.80], P < 0.01). CONCLUSION: Females are more likely to develop cardiac, renal, bleeding, pulmonary and TEE-related complications following LAAO procedure, while concurrently showing higher mortality, length of stay and discharge to facilities.


Assuntos
Apêndice Atrial , Fibrilação Atrial , Acidente Vascular Cerebral , Doenças Vasculares , Masculino , Humanos , Feminino , Resultado do Tratamento , Apêndice Atrial/diagnóstico por imagem , Apêndice Atrial/cirurgia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Fibrilação Atrial/complicações , Hemorragia , Hospitais , Doenças Vasculares/etiologia , Cateterismo Cardíaco , Acidente Vascular Cerebral/etiologia
20.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37622589

RESUMO

This article will discuss the past, present, and future of ventricular tachycardia ablation and the continuing contribution of the Europace journal as the platform for publication of milestone research papers in this field of ventricular tachycardia ablation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/cirurgia , Ablação por Cateter/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA