Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 13 de 13
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Surgeon ; 19(5): e289-e297, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33597085

RESUMO

Acetabular fractures in the elderly are challenging. Management is complicated by patients' poor physiological status and osteoporotic bone. Analysis of the management of these patients must be separated from the treatment of younger patients. Conservative management continues to have a role in patients who sustain fractures that are non-displaced and are considered stable with weight bearing mobilisation, and in those patients considered too medically frail to undergo surgical intervention. The mainstay of current surgical intervention is open reduction and internal fixation (ORIF) and variations of ORIF and total hip arthroplasty (THA), or fix and replace. Fix and replace is being increasingly favoured in those patients who display poor prognostic factors for long term joint survival after ORIF. Percutaneous fixation has the theoretical benefits of minimally invasive surgery and the potential to make any subsequent THA less complicated. However, it requires specialised fluoroscopic skills and is not suitable for all fracture patterns. There are a number of developments being reported. The use of a reinforcement ring and THA in has been reported in a number of centres, as has the use of trabecular metal acetabular implants. A coned hemi pelvic prosthesis and THA has been described in our centre, with promising early results. The potential for 3D printing to improve preoperative planning and reduce intra-operative time is also being explored. The aim of this review is to provide a summary of the literature supporting current and future treatment methods, tips on reduction techniques and an overview of the treatment algorithm of these patients in our unit.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Fraturas do Quadril , Acetábulo/cirurgia , Idoso , Fixação Interna de Fraturas , Fraturas Ósseas/cirurgia , Fraturas do Quadril/cirurgia , Humanos , Redução Aberta , Estudos Retrospectivos , Resultado do Tratamento
2.
J Arthroplasty ; 33(2): 537-543, 2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-29056307

RESUMO

BACKGROUND: Excellent medium-term to long-term results for function and survivorship have been shown with mobile-bearing (MB) total knee arthroplasty (TKA). One of the key arguments against its use is the risk of "spinout" or dislocation of the MB. The aim of this study is to discuss the etiology, prevention, incidence, management, and outcome of spinout. METHODS: Between October 1993 and February 2016, 8373 consecutive primary MB TKAs were performed irrespective of preoperative deformity. Before 2001, soft-tissue knee balancing was achieved by release of collateral ligaments and all spinouts were treated by open reduction. Thereafter, soft-tissue balancing was achieved without ligament release and with the use of a higher conformity MB and all spinouts were reduced closed, giving 2 comparative cohorts. RESULTS: Twenty-six spinouts occurred in 8373 (0.31%) patients. In the first cohort up until May 2001, there were 14 spinouts of 2379 (0.58%) cases. There were 12 in cohort 2, in those patients having surgery after May 2001, thus giving an incidence of 12 of 5994 (0.2%), which was significantly lower than in cohort 1 (P < .01). Spinout was associated with the valgus knee (P < .01) and most (73%) occurred within the first 6 months. There was 1 arthrodesis in cohort 1 and 1 both-component revision in cohort 2. CONCLUSION: The etiology of spinout is flexion gap instability. It can normally be reduced closed with recurrence being uncommon. Focus on soft-tissue balance necessary with an MB TKA can reduce the incidence of revision for instability as compared to a fixed-bearing TKA. Therefore, the risk of spinout should not be used as an argument against the MB TKA.


Assuntos
Artroplastia do Joelho/métodos , Luxações Articulares/cirurgia , Articulação do Joelho/cirurgia , Prótese do Joelho , Osteoartrite do Joelho/cirurgia , Amplitude de Movimento Articular , Adulto , Idoso , Idoso de 80 Anos ou mais , Ligamentos Colaterais/cirurgia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Recidiva , Resultado do Tratamento , Suporte de Carga
3.
J Arthroplasty ; 33(9): 2961-2966, 2018 09.
Artigo em Inglês | MEDLINE | ID: mdl-29807791

RESUMO

BACKGROUND: Instability remains one of the main problems after revision hip surgery. The aim of this study was to review the clinical, radiological, and patient-reported outcomes with the use of modular dual-mobility articulation for revision acetabular reconstruction and investigate the risk of fretting corrosion by measuring serum trace metal ion levels. METHODS: Sixty consecutive patients with a minimum of 24-month follow-up after the insertion of a modular dual-mobility (Stryker, Mahwah, NJ) cup at the time of revision hip surgery were identified. Follow-up included clinical and radiological patient review and functional outcome measures, and a subset of patients had their metal ion (cobalt and chromium) levels checked. RESULTS: At the most recent follow-up, 5 patients had died, 3 patients have been revised because of ongoing instability, and 3 patients have had revision surgery due to infection. Overall functional outcome (mean Western Ontario and McMaster Universities Osteoarthritis Indexfunction 76, University of California, Los Angeles 5.6, mean Oxford 74.7, Short Form-12 physical 41.6/mental 53.3) and overall pain relief (mean Western Ontario and McMaster Universities Osteoarthritis Index pain score 78.3) scores were good. The mean satisfaction score was 78 of 100. The median serum trace metal chromium and cobalt levels at the most recent follow-up were 0.4 µg/L (range 0.1-6.1 µg/L) and 0.42 µg/L (range 0.21-9.42 µg/L), respectively. The survival with revision as the end point was 90%. CONCLUSIONS: Dual-mobility cups with modularity represent an excellent option for the patient having revision hip surgery at high risk of instability. This series presents good patient-reported outcome measures and a low complication and revision rate.


Assuntos
Acetábulo/cirurgia , Artroplastia de Quadril/efeitos adversos , Prótese de Quadril/efeitos adversos , Reoperação/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Cromo/sangue , Cobalto/sangue , Corrosão , Feminino , Seguimentos , Humanos , Íons/sangue , Estudos Longitudinais , Masculino , Metais/sangue , Pessoa de Meia-Idade , Osteoartrite/diagnóstico , Osteoartrite/cirurgia , Desenho de Prótese , Amplitude de Movimento Articular , Reprodutibilidade dos Testes , Índice de Gravidade de Doença , Resultado do Tratamento
4.
J Hip Preserv Surg ; 10(3-4): 253-255, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38628399

RESUMO

Femoral de-rotational osteotomies are a safe and effective treatment for symptomatic excessive femoral anteversion or retroversion. The author's preferred technique for performing a de-rotational osteotomy is via a subtrochanteric transverse osteotomy with intramedullary nail fixation. We describe a method for guiding femoral de-rotation correction intra-operatively using a bubble inclinometer.

5.
Hip Int ; 33(6): 1093-1099, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36541413

RESUMO

INTRODUCTION: The incidence of acetabular fractures in older patients is increasing. The management of these patients is evolving due to the recognition of risks associated with prolonged immobility with conservative treatment. MATERIALS AND METHODS: Consecutive patients undergoing fixation and total hip replacement (THR) for displaced acetabular fractures undergoing single operation with acetabular fixation and THR were identified. Outcomes were assessed using radiographs, clinical notes, Oxford Hip Score and EuroQol-5L. RESULTS: 77 patients were identified with 51 completing outcome scores. Mean age 68 years at time of injury. Mean follow-up 5 (2-12) years, OHS 40, EQ-5D 0.78. Revision surgery performed in 7 patients (9%). DISCUSSION: Acute fixation combined with THR for acetabular fractures in the elderly patient, offers good functional outcomes and a low complication rate in the mid-term.


Assuntos
Artroplastia de Quadril , Fraturas Ósseas , Fraturas do Quadril , Humanos , Idoso , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Resultado do Tratamento , Fraturas do Quadril/cirurgia , Acetábulo/diagnóstico por imagem , Acetábulo/cirurgia , Acetábulo/lesões , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Estudos Retrospectivos
6.
Hip Int ; 32(5): 627-633, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33829898

RESUMO

AIMS: Traditional methods of determining femoral head centre (FHC) during total hip arthroplasty (THA) rely on measuring the distance from a fixed point on the femur or using a calliper. The aim of this experiment was to investigate how accurately a simple circular ring could locate FHC. METHODS: 144 consecutively available femoral heads (FHs) were collected from patients undergoing THA. Each FH was orientated and mounted on a Sawbone, to create a model of its position on a proximal femur. The ring was applied to the posterior aspect of the FH and a head-centre pin (HCP) was then drilled into the FH and the ring removed, leaving the HCP in place.Each FH was then photographed normal to the axis of the HCP. A MATLAB analysis program then assessed the accuracy of the ring in locating FHC. RESULTS: Mean location accuracy for FHC was 1.77 (range 0.07-5.83) mm with 97.2% within 4 mm and all but 1 within 5 mm. CONCLUSIONS: This ring device located FHC to within 4 mm in 97% of a series of osteoarthritic FHs. This indicates that the posterior aspect of the FH maintains its sphericity late into the osteoarthritic process. Having a simple FHC location device during THA would be of value to control leg length and offset when using the posterior approach.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Artroplastia de Quadril/efeitos adversos , Artroplastia de Quadril/métodos , Fêmur/cirurgia , Cabeça do Fêmur/cirurgia , Humanos , Extremidade Inferior
7.
Bone Joint J ; 102-B(2): 155-161, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32009440

RESUMO

AIMS: Complex displaced osteoporotic acetabular fractures in the elderly are associated with high levels of morbidity and mortality. Surgical options include either open reduction and internal fixation alone, or combined with total hip arthroplasty (THA). There remains a cohort of severely comorbid patients who are deemed unfit for extensive surgical reconstruction and are treated conservatively. We describe the results of a coned hemipelvis reconstruction and THA inserted via a posterior approach to the hip as the primary treatment for this severely high-risk cohort. METHODS: We have prospectively monitored a series of 22 cases (21 patients) with a mean follow-up of 32 months (13 to 59). RESULTS: The mean patient age was 79 years (67 to 87), and the mean ASA score was 3.3 (3 to 5). Three patients had high-energy injuries and 18 had low-energy injuries. All cases were associated fractures (Letournel classification: anterior column posterior hemitransverse, n = 13; associated both column, n = 6; transverse posterior wall, n = 3) with medialization of the femoral head. Mean operative time was 93 minutes (61 to 135). There have been no revisions to date. Of the 21 patients, 20 were full weight-bearing on day 1 postoperatively. Mean length of hospital stay was 12 days (5 to 27). Preoperative mobility status was maintained in 13 patients. At one year, mean Merle d'Aubigné score was 13.1 (10 to 18), mean Oxford Hip Score was 38.5 (24 to 44), mean EuroQol five-dimension five-level (EQ-5D-5L) health score was 68 (30 to 92), and mean EQ-5D-5L index score was 0.68 (0.335 to 0.837); data from 14 patients. Mortality was 9.5% (2/21) at one year. There have been no thromboembolic events, deep infections, or revisions. CONCLUSION: The coned hemipelvis reconstruction bypasses the fracture, creating an immediately stable construct that allows immediate full weight-bearing. The posterior approach minimizes the operative time and physiological insult in this vulnerable patient population. Early results suggest this to be a safe addition to current surgical options, targeted at the most medically frail elderly patient with a complex displaced acetabular fracture. Cite this article: Bone Joint J 2020;102-B(2):155-161.


Assuntos
Acetábulo/cirurgia , Fraturas Ósseas/cirurgia , Idoso Fragilizado , Fraturas por Osteoporose/cirurgia , Ossos Pélvicos/cirurgia , Acetábulo/lesões , Idoso , Idoso de 80 Anos ou mais , Artroplastia de Quadril/métodos , Comores , Feminino , Fixação Interna de Fraturas/métodos , Humanos , Masculino , Procedimentos de Cirurgia Plástica/métodos , Suporte de Carga
8.
Bone Joint J ; 102-B(9): 1146-1150, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32862677

RESUMO

AIMS: Previous research has demonstrated increased early complication rates following total hip arthroplasty (THA) in obese patients, as defined by body mass index (BMI). Subcutaneous fat depth (FD) has been shown to be an independent risk factor for wound infection in cervical and lumbar spine surgery, as well as after abdominal laparotomy. The aim of this study was to investigate whether increased peritrochanteric FD was associated with an increased risk of complications in the first year following THA. METHODS: We analyzed prospectively collected data on a consecutive series of 1,220 primary THAs from June 2013 until May 2018. The vertical soft tissue depth from the most prominent part of the greater trochanter to the skin was measured intraoperatively using a sterile ruler and recorded to the nearest millimetre. BMI was calculated at the patient's preoperative assessment. All surgical complications occuring within the initial 12 months of follow-up were identified. RESULTS: Females had a significantly greater FD at the greater trochanter in comparison to males (median 3.0 cm (interquartile range (IQR) 2.3 to 4.0) vs 2.0 cm (IQR 1.7 to 3.0); p < 0.001) despite equivalent BMI between sexes (male median BMI 30.0 kg/m2 (IQR 27.0 to 33.0); female median 29.0 kg/m2 (IQR 25.0 to 33.0)). FD showed a weak correlation with BMI (R² 0.41 males and R² 0.43 females). Patients with the greatest FD (upper quartile) were at no greater risk of complications compared with patients with the lowest FD (lower quartile); 7/311 (2.3%) vs 9/439 (2.1%); p = 0.820 . Conversely, patients with the highest BMI (≥ 40 kg/m2) had a significantly increased risk of complications compared with patients with lower BMI (< 40 kg/m2); 5/60 (8.3% vs 18/1,160 (1.6%), odds ratio (OR) 5.77 (95% confidence interval (CI) 2.1 to 16.1; p = 0.001)). CONCLUSION: We found no relationship between peritrochanteric FD and the risk of surgical complications following primary THA. Cite this article: Bone Joint J 2020;102-B(9):1146-1150.


Assuntos
Artroplastia de Quadril , Complicações Pós-Operatórias/epidemiologia , Gordura Subcutânea/anatomia & histologia , Idoso , Feminino , Humanos , Masculino , Estudos Prospectivos , Medição de Risco , Fatores de Risco
9.
Int J Surg ; 54(Pt B): 345-350, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28716659

RESUMO

Peri-prosthetic joint infection remains one of the most difficult and challenging complications following hip and knee arthroplasty for both patients and surgeons. Two-stage revision arthroplasty for infection remains the most popular option for the majority of patients and arguably the only option for some. The use antibiotic spacers and in particular articulating spacers has improved the quality of life for patients between stages. The spacers provides local delivery of high concentration antibiotics and provides many benefits to the soft tissues including maintaining soft tissue tension and range of movement. This benefit to the soft tissues also translates into reducing the difficulty and time spent doing the exposure during the second stage procedure. It is generally accepted that peri-prosthetic joint infection should be dealt with my specialist centers who deal with high volumes of patients with this diagnosis in a multidisciplinary approach.


Assuntos
Antibacterianos/administração & dosagem , Artroplastia/efeitos adversos , Bombas de Infusão Implantáveis , Prótese Articular/efeitos adversos , Infecções Relacionadas à Prótese/tratamento farmacológico , Idoso , Artroplastia/métodos , Artroplastia do Joelho/efeitos adversos , Feminino , Articulação do Quadril/cirurgia , Humanos , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas à Prótese/etiologia , Qualidade de Vida , Reoperação/métodos
10.
Knee ; 25(4): 657-662, 2018 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-29884560

RESUMO

BACKGROUND: Fracture of a polyethylene tibial post after a posterior stabilized total knee arthroplasty (PS-TKA) is an uncommon but severe complication. We report five cases of non-traumatic fracture of a tibial polyethylene post that occurred with Prolong highly cross-linked polyethylene with the NexGen LPS-Flex total knee prosthesis. METHODS: A Joint Reconstruction database for a high volume arthroplasty unit was used to identify all cases of revision of Prolong polyethylene used in PS-TKA. Five cases were identified as being revised because of a broken tibial post. RESULTS: All five cases presented with a combination of sudden and increasing pain, instability and giving way, in previously well-functioning TKAs. There was no history of trauma or precipitating incident. Mean time from primary TKA to presentation and diagnosis of post fracture was 67.7 months (range 24-108). All five cases were successfully treated by revision, in the form of a liner exchange to a standard ultra-high molecular weight polyethylene (UHMWPE) bearing of the same thickness. The five cases occurred from a consecutive series of 955 total PS-TKAs with Prolong. This gives a conservative estimate of the frequency of this complication of 0.52%. This would give a risk of a tibial post fracture in approximately one in every 200 TKAs with this specific implant and bearing combination. CONCLUSIONS: To our knowledge, this is the first report of a non-traumatic fracture to the tibial post with this bearing type. We would advocate against the routine use of Prolong highly crosslinked polyethylene in PS-TKA.


Assuntos
Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/instrumentação , Prótese do Joelho , Polietileno , Falha de Prótese , Fraturas da Tíbia/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polietilenos , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Fraturas da Tíbia/cirurgia
11.
Case Rep Emerg Med ; 2015: 802753, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26543652

RESUMO

Acetabular liner dissociation is a rare complication of Total Hip Arthroplasty (THA) which requires urgent revision surgery. A case is presented in which the correct diagnosis was not appreciated on two separate Emergency Department attendances. The typical symptoms, signs, and radiological features are outlined and the importance of considering a rare complication following a commonly performed procedure is highlighted.

12.
Hip Int ; 23(1): 104-7, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23417532

RESUMO

Total hip arthroplasty in patients with previous above knee amputations is rare. We present a unique case where the patient had only 130 mm of proximal femur remaining following a previous traumatic above knee amputation. The short segment of femur meaning a conventional femoral stem could not be used. We describe the technique of total hip arthoplasty for this patient using a mini hip prosthesis and report a successful clinical and radiological outcome at 2 years post-op.


Assuntos
Amputação Traumática/cirurgia , Artroplastia de Quadril/métodos , Prótese de Quadril , Traumatismos da Perna/cirurgia , Desenho de Prótese , Adulto , Membros Artificiais , Feminino , Articulação do Quadril/diagnóstico por imagem , Humanos , Perna (Membro) , Radiografia , Suporte de Carga
13.
Ulster Med J ; 80(2): 82-3, 2011 May.
Artigo em Inglês | MEDLINE | ID: mdl-22347749

RESUMO

We describe a patient who sustained an extra-articular, oblique and angulated first metatarsal fracture. The medial hallucal sesamoid bone was subsequently found to have entered the fracture gap preventing reduction. We describe treatment of this rare injury with a successful outcome.


Assuntos
Fixação Interna de Fraturas/métodos , Fraturas Ósseas/cirurgia , Ossos do Metatarso/lesões , Ossos Sesamoides/lesões , Adulto , Fraturas Ósseas/diagnóstico por imagem , Humanos , Masculino , Ossos do Metatarso/diagnóstico por imagem , Ossos do Metatarso/cirurgia , Radiografia , Ossos Sesamoides/diagnóstico por imagem , Ossos Sesamoides/cirurgia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA