Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 206
Filtrar
1.
N Engl J Med ; 389(17): 1553-1565, 2023 Oct 26.
Artigo em Inglês | MEDLINE | ID: mdl-37888916

RESUMO

BACKGROUND: Transthyretin amyloidosis, also called ATTR amyloidosis, is associated with accumulation of ATTR amyloid deposits in the heart and commonly manifests as progressive cardiomyopathy. Patisiran, an RNA interference therapeutic agent, inhibits the production of hepatic transthyretin. METHODS: In this phase 3, double-blind, randomized trial, we assigned patients with hereditary, also known as variant, or wild-type ATTR cardiac amyloidosis, in a 1:1 ratio, to receive patisiran (0.3 mg per kilogram of body weight) or placebo once every 3 weeks for 12 months. A hierarchical procedure was used to test the primary and three secondary end points. The primary end point was the change from baseline in the distance covered on the 6-minute walk test at 12 months. The first secondary end point was the change from baseline to month 12 in the Kansas City Cardiomyopathy Questionnaire-Overall Summary (KCCQ-OS) score (with higher scores indicating better health status). The second secondary end point was a composite of death from any cause, cardiovascular events, and change from baseline in the 6-minute walk test distance over 12 months. The third secondary end point was a composite of death from any cause, hospitalizations for any cause, and urgent heart failure visits over 12 months. RESULTS: A total of 360 patients were randomly assigned to receive patisiran (181 patients) or placebo (179 patients). At month 12, the decline in the 6-minute walk distance was lower in the patisiran group than in the placebo group (Hodges-Lehmann estimate of median difference, 14.69 m; 95% confidence interval [CI], 0.69 to 28.69; P = 0.02); the KCCQ-OS score increased in the patisiran group and declined in the placebo group (least-squares mean difference, 3.7 points; 95% CI, 0.2 to 7.2; P = 0.04). Significant benefits were not observed for the second secondary end point. Infusion-related reactions, arthralgia, and muscle spasms occurred more often among patients in the patisiran group than among those in the placebo group. CONCLUSIONS: In this trial, administration of patisiran over a period of 12 months resulted in preserved functional capacity in patients with ATTR cardiac amyloidosis. (Funded by Alnylam Pharmaceuticals; APOLLO-B ClinicalTrials.gov number, NCT03997383.).


Assuntos
Amiloidose , Cardiomiopatias , Pré-Albumina , RNA Interferente Pequeno , Humanos , Cardiomiopatias/tratamento farmacológico , Cardiomiopatias/etiologia , Cardiomiopatias/genética , Cardiomiopatias/metabolismo , Pré-Albumina/genética , Pré-Albumina/metabolismo , RNA Interferente Pequeno/uso terapêutico , Amiloidose Familiar/complicações , Amiloidose Familiar/tratamento farmacológico , Amiloidose Familiar/genética , Fígado/metabolismo , Método Duplo-Cego , Amiloidose/complicações , Amiloidose/tratamento farmacológico , Amiloidose/genética
2.
J Med Syst ; 48(1): 57, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801649

RESUMO

Wearable electronics are increasingly common and useful as health monitoring devices, many of which feature the ability to record a single-lead electrocardiogram (ECG). However, recording the ECG commonly requires the user to touch the device to complete the lead circuit, which prevents continuous data acquisition. An alternative approach to enable continuous monitoring without user initiation is to embed the leads in a garment. This study assessed ECG data obtained from the YouCare device (a novel sensorized garment) via comparison with a conventional Holter monitor. A cohort of thirty patients (age range: 20-82 years; 16 females and 14 males) were enrolled and monitored for twenty-four hours with both the YouCare device and a Holter monitor. ECG data from both devices were qualitatively assessed by a panel of three expert cardiologists and quantitatively analyzed using specialized software. Patients also responded to a survey about the comfort of the YouCare device as compared to the Holter monitor. The YouCare device was assessed to have 70% of its ECG signals as "Good", 12% as "Acceptable", and 18% as "Not Readable". The R-wave, independently recorded by the YouCare device and Holter monitor, were synchronized within measurement error during 99.4% of cardiac cycles. In addition, patients found the YouCare device more comfortable than the Holter monitor (comfortable 22 vs. 5 and uncomfortable 1 vs. 18, respectively). Therefore, the quality of ECG data collected from the garment-based device was comparable to a Holter monitor when the signal was sufficiently acquired, and the garment was also comfortable.


Assuntos
Eletrocardiografia Ambulatorial , Eletrocardiografia , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Adulto , Eletrocardiografia Ambulatorial/instrumentação , Eletrocardiografia Ambulatorial/métodos , Idoso de 80 Anos ou mais , Eletrocardiografia/instrumentação , Eletrocardiografia/métodos , Dispositivos Eletrônicos Vestíveis , Adulto Jovem , Vestuário , Processamento de Sinais Assistido por Computador/instrumentação
3.
Europace ; 25(11)2023 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-37757839

RESUMO

AIMS: While numerous studies have demonstrated favourable safety and efficacy of the excimer laser sheath for transvenous lead extraction (TLE) in smaller cohorts, comprehensive large-scale investigations with contemporary data remain scarce. This study aims to evaluate the safety and performance of laser-assisted TLE through a meta-analysis of contemporary data. METHODS AND RESULTS: A systematic literature search was conducted to identify articles that assessed the safety and performance of the spectranetics laser sheath (SLS) II and GlideLight Excimer laser sheaths in TLE procedures between 1 April 2016 and 31 March 2021. Safety outcomes included procedure-related death and major/minor complications. Performance outcomes included procedural and clinical success rates. A random-effects, inverse-variance-weighting meta-analysis was performed to obtain the weighted average of the evaluated outcomes. In total, 17 articles were identified and evaluated, including 1729 patients with 2887 leads. Each patient, on average, had 2.3 ± 0.3 leads with a dwell time of 7.9 ± 3.0 years. The TLE procedural successes rate was 96.8% [1440/1505; 95% CI: (94.9-98.2%)] per patient and 96.3% [1447/1501; 95% CI: (94.8-97.4%)] per lead, and the clinical success rate per patient was 98.3% [989/1010, 95% CI: (97.4-99.0%)]. The procedure-related death rate was 0.08% [7/1729, 95% CI: (0.00%, 0.34%)], with major and minor complication rates of 1.9% [41/1729; 95% CI: (1.2-2.8%)] and 1.9% [58/1729; 95% CI: (0.8-3.6%)], respectively. CONCLUSION: This meta-analysis demonstrated that excimer laser sheath-assisted TLE has high success and low procedural mortality rates. It provides clinicians with a reliable and valuable resource for extracting indwelling cardiac leads which require advanced extraction techniques.


Assuntos
Remoção de Dispositivo , Humanos , Remoção de Dispositivo/efeitos adversos , Remoção de Dispositivo/métodos , Lasers de Excimer/efeitos adversos , Marca-Passo Artificial , Estudos Retrospectivos , Resultado do Tratamento
4.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37713182

RESUMO

AIMS: Heart failure (HF) is a risk factor for major adverse events in atrial fibrillation (AF). Whether this risk persists on non-vitamin K antagonist oral anticoagulants (NOACs) and varies according to left ventricular ejection fraction (LVEF) is debated. METHODS AND RESULTS: We investigated the relation of HF in the ETNA-AF-Europe registry, a prospective, multicentre, observational study with an overall 4-year follow-up of edoxaban-treated AF patients. We report 2-year follow-up for ischaemic stroke/transient ischaemic attack (TIA)/systemic embolic events (SEE), major bleeding, and mortality. Of the 13 133 patients, 1854 (14.1%) had HF. Left ventricular ejection fraction was available for 82.4% of HF patients and was <40% in 671 (43.9%) and ≥40% in 857 (56.1%). Patients with HF were older, more often men, and had more comorbidities. Annualized event rates (AnERs) of any stroke/SEE were 0.86%/year and 0.67%/year in patients with and without HF. Compared with patients without HF, those with HF also had higher AnERs for major bleeding (1.73%/year vs. 0.86%/year) and all-cause death (8.30%/year vs. 3.17%/year). Multivariate Cox proportional models confirmed HF as a significant predictor of major bleeding [hazard ratio (HR) 1.65, 95% confidence interval (CI): 1.20-2.26] and all-cause death [HF with LVEF <40% (HR 2.42, 95% CI: 1.95-3.00) and HF with LVEF ≥40% (HR 1.80, 95% CI: 1.45-2.23)] but not of ischaemic stroke/TIA/SEE. CONCLUSION: Anticoagulated patients with HF at baseline featured higher rates of major bleeding and all-cause death, requiring optimized management and novel preventive strategies. NOAC treatment was similarly effective in reducing risk of ischaemic events in patients with or without concomitant HF.


Assuntos
Fibrilação Atrial , Isquemia Encefálica , Embolia , Insuficiência Cardíaca , Ataque Isquêmico Transitório , AVC Isquêmico , Acidente Vascular Cerebral , Masculino , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Anticoagulantes/efeitos adversos , Ataque Isquêmico Transitório/diagnóstico , Ataque Isquêmico Transitório/epidemiologia , Ataque Isquêmico Transitório/prevenção & controle , Estudos Prospectivos , Volume Sistólico/fisiologia , Administração Oral , Função Ventricular Esquerda , Hemorragia/induzido quimicamente , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/epidemiologia , Sistema de Registros
5.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-37038759

RESUMO

AIMS: To allow timely initiation of anticoagulation therapy for the prevention of stroke, the European guidelines on atrial fibrillation (AF) recommend remote monitoring (RM) of device-detected atrial high-rate episodes (AHREs) and progression of arrhythmia duration along pre-specified strata (6 min…<1 h, 1 h…<24 h, ≥ 24 h). We used the MATRIX registry data to assess the capability of a single-lead implantable cardioverter-defibrillator (ICD) with atrial sensing dipole (DX ICD system) to follow this recommendation in patients with standard indication for single-chamber ICD. METHODS AND RESULTS: In 1841 DX ICD patients with daily automatic RM transmissions, electrograms of first device-detected AHREs per patient in each duration stratum were adjudicated, and the corresponding positive predictive values (PPVs) for the detections to be true atrial arrhythmia were calculated. Moreover, the incidence and progression of new-onset AF was assessed in 1451 patients with no AF history. A total of 610 AHREs ≥6 min were adjudicated. The PPV was 95.1% (271 of 285) for episodes 6min…<1 h, 99.6% (253/254) for episodes 1 h…<24 h, 100% (71/71) for episodes ≥24 h, or 97.5% for all episodes (595/610). The incidence of new-onset AF was 8.2% (119/1451), and in 31.1% of them (37/119), new-onset AF progressed to a higher duration stratum. Nearly 80% of new-onset AF patients had high CHA2DS2-VASc stroke risk, and 70% were not on anticoagulation therapy. Age was the only significant predictor of new-onset AF. CONCLUSION: A 99.7% detection accuracy for AHRE ≥1 h in patients with DX ICD systems in combination with daily RM allows a reliable guideline-recommended screening for subclinical AF and monitoring of AF-duration progression.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Fibrilação Atrial/epidemiologia , Desfibriladores Implantáveis/efeitos adversos , Átrios do Coração , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/etiologia , Anticoagulantes
6.
Int J Mol Sci ; 24(7)2023 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-37047444

RESUMO

ANP is mainly synthesized by the atria, and upon excretion, it serves two primary purposes: vasodilation and increasing the renal excretion of sodium and water. The understanding of ANP's role in cardiac systems has improved considerably in recent decades. This review focuses on several studies demonstrating the importance of analyzing the regulations between the endocrine and mechanical function of the heart and emphasizes the effect of ANP, as the primary hormone of the atria, on atrial fibrillation (AF) and related diseases. The review first discusses the available data on the diagnostic and therapeutic applications of ANP and then explains effect of ANP on heart failure (HF) and atrial fibrillation (AF) and vice versa, where tracking ANP levels could lead to understanding the pathophysiological mechanisms operating in these diseases. Second, it focuses on conventional treatments for AF, such as cardioversion and catheter ablation, and their effects on cardiac endocrine and mechanical function. Finally, it provides a point of view about the delayed recovery of cardiac mechanical and endocrine function after cardioversion, which can contribute to the occurrence of acute heart failure, and the potential impact of restoration of the sinus rhythm by extensive ablation or surgery in losing ANP-producing sites. Overall, ANP plays a key role in heart failure through its effects on vasodilation and natriuresis, leading to a decrease in the activity of the renin-angiotensin-aldosterone system, but it is crucial to understand the intimate role of ANP in HF and AF to improve their diagnosis and personalizing the patients' treatment.


Assuntos
Amiloidose , Fibrilação Atrial , Insuficiência Cardíaca , Humanos , Fator Natriurético Atrial , Átrios do Coração , Insuficiência Cardíaca/etiologia
7.
J Cardiovasc Electrophysiol ; 33(7): 1472-1479, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35499267

RESUMO

INTRODUCTION: The Respiratory Disturbance Index (RDI) computed by an implantable cardioverter defibrillator (ICD) algorithm accurately identifies severe sleep apnea (SA). In the present analysis, we tested the hypothesis that RDI could also predict atrial fibrillation (AF) burden. METHODS: Patients with ejection fraction ≤35% implanted with an ICD were enrolled and followed up for 24 months. One month after implantation, patients underwent a polysomnographic study. The weekly mean RDI value was considered, as calculated during the entire follow-up period and over a 1-week period preceding the sleep study. The endpoints were as follows: daily AF burden of ≥5 min, ≥6 h, ≥23 h. RESULTS: Here, 164 patients had usable RDI values during the entire follow-up period. Severe SA (RDI ≥ 30 episodes/h) was diagnosed in 92 (56%) patients at the time of the sleep study. During follow-up, AF burden ≥ 5 min/day was documented in 70 (43%), ≥6 h/day in 48 (29%), and ≥23 h/day in 33 (20%) patients. Device-detected RDI ≥ 30 episodes/h at the time of the polygraphy, as well as the polygraphy-measured apnea hypopnea index ≥ 30 episodes/h, were not associated with the occurrence of the endpoints, using a Cox regression model. However, using a time-dependent model, continuously measured weekly mean RDI ≥ 30 episodes/h was independently associated with AF burden ≥ 5 min/day (hazard ratio [HR]: 2.13, 95% confidence interval [CI]: 1.24-3.65, p = .006), ≥6 h/day (HR: 2.75, 95% CI: 1.37-5.49, p = .004), and ≥23 h/day (HR: 2.26, 95% CI: 1.05-4.86, p = .037). CONCLUSIONS: In heart failure patients, ICD-diagnosed severe SA on follow-up data review identifies patients who are from two- to three-fold more likely to experience an AF episode, according to various thresholds of daily AF burden.


Assuntos
Fibrilação Atrial , Desfibriladores Implantáveis , Insuficiência Cardíaca , Síndromes da Apneia do Sono , Algoritmos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/terapia , Insuficiência Cardíaca/complicações , Humanos , Síndromes da Apneia do Sono/complicações , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/terapia
8.
Eur J Clin Invest ; 52(7): e13773, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35305020

RESUMO

BACKGROUND: The management of patients with atrial fibrillation (AF) and malignancy is challenging given the paucity of evidence supporting their appropriate clinical management. PURPOSE: To evaluate the outcomes of patients with active or prior malignancy in a contemporary cohort of European AF patients. METHODS: Patients enrolled in the EURObservational Research Programme in AF General Long-Term Registry were categorized into 3 categories: No Malignancy (NoMal), Prior Malignancy (PriorMal) and Active Malignancy (ActiveMal). The primary outcomes were all-cause death and the composite outcome MACE. RESULTS: A total of 10 383 patients were analysed. Of these, 9597 (92.4%) were NoMal patients, 577 (5.6%) PriorMal and 209 (2%) ActiveMal. Lack of any antithrombotic treatment was more prevalent in ActiveMal patients (12.4%) as compared to other groups (5.0% vs 6.3% for PriorMal and NoMal, p < .001). After a median follow-up of 730 days, there were 982 (9.5%) deaths and 950 (9.7%) MACE events. ActiveMal was independently associated with a higher risk for all-cause death (HR 2.90, 95% CI 2.23-3.76) and MACE (HR 1.54, 95% CI 1.03-2.31), as well as any haemorrhagic events and major bleeding (OR 2.42, 95% CI 1.49-3.91 and OR 4.18, 95% CI 2.49-7.01, respectively). Use of oral anticoagulants was not significantly associated with a higher risk for all-cause death or bleeding in ActiveMal patients. CONCLUSIONS: In a large contemporary cohort of AF patients, active malignancy was independently associated with all-cause death, MACE and haemorrhagic events. Use of anticoagulants was not associated with a higher risk of all-cause death in patients with active malignancies.


Assuntos
Fibrilação Atrial , Neoplasias , Acidente Vascular Cerebral , Anticoagulantes , Fibrilação Atrial/complicações , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Neoplasias/tratamento farmacológico , Sistema de Registros , Fatores de Risco , Acidente Vascular Cerebral/complicações , Acidente Vascular Cerebral/epidemiologia
9.
Rev Cardiovasc Med ; 23(3): 107, 2022 Mar 17.
Artigo em Inglês | MEDLINE | ID: mdl-35345274

RESUMO

Cardiac simulation has moved from early life-saving pacemakers meant only to prevent asystole to current devices capable of physiologic stimulation for the treatment of heart rhythm and heart failure, that are also intended for remote patient and disease-progression monitoring. The actual vision of contemporary pacing aims to correct the electrophysiologic roots of mechanical inefficiency regardless of underlying structural heart diseases. The awareness of the residual cardiac dyssynchrony related to customary cardiac pacing has changed the concept of what truly represents "physiologic pacing". On a different perspective, leadless stimulation to abolish CIED surgery and prevent lead-related complications is becoming a priority both for young device recipients and for frail, elderly patients. Careful clinical evaluation attempts to bridge decision-making to patient-tailored therapy.


Assuntos
Insuficiência Cardíaca , Marca-Passo Artificial , Idoso , Desenho de Equipamento , Previsões , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos
10.
J Nucl Cardiol ; 29(2): 633-641, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-33241474

RESUMO

Nuclear imaging techniques like single-photon emission computed tomography (SPECT) and radionuclide angiography have wide applications in patients receiving a cardiac implantable electrical device (CIED), who cannot usually undergo cardiac magnetic resonance. Our aim was to provide an update of single-photon imaging clinical applications, with a specific focus on CIED recipients. SPECT imaging is commonly used in CIED patients to assess myocardial perfusion, but it can also be used to evaluate myocardial viability, which is an important predictor of LV function improvement by cardiac resynchronization therapy (CRT). Radionuclide angiography has shown higher temporal resolution and reproducibility than SPECT in the evaluation of cardiac function and dyssynchrony. Left ventricular dyssynchrony as assessed by radionuclide angiography with phase analysis may be reliably used for CRT patient selection and evaluation of CRT response. SPECT imaging with meta-iodo-benzyl-guanidine allows for cardiac sympathetic innervation examination, which may be used for prognostic stratification of heart failure patients and prediction of ventricular tachyarrhythmias. Finally, promising results in CIED infection diagnosis have been shown by SPECT with radiolabeled autologous white blood cells.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Imagem de Perfusão do Miocárdio , Disfunção Ventricular Esquerda , Insuficiência Cardíaca/diagnóstico por imagem , Insuficiência Cardíaca/terapia , Humanos , Imagem de Perfusão do Miocárdio/métodos , Reprodutibilidade dos Testes , Tomografia Computadorizada de Emissão de Fóton Único/métodos
11.
Europace ; 24(9): 1404-1411, 2022 10 13.
Artigo em Inglês | MEDLINE | ID: mdl-35512229

RESUMO

AIMS: Frailty is common in patients with atrial fibrillation (AF), with possible impact on therapies and outcomes. However, definitions of frailty are variable, and may not overlap with frailty perception among physicians. We evaluated the prevalence of frailty as perceived by enrolling physicians in the Edoxaban Treatment in Routine Clinical Practice for Patients With Non-Valvular AF (ETNA-AF)-Europe registry (NCT02944019), and compared it with an objective frailty assessment. METHODS AND RESULTS: ETNA-AF-Europe is a prospective, multi-centre, post-authorization, observational study. There we assessed the presence of frailty according to (i) a binary subjective investigators' judgement and (ii) an objective measure, the Modified Frailty Index. Baseline data on frailty were available in 13 621/13 980 patients. Prevalence of perceived frailty was 10.6%, with high variability among participating countries and healthcare settings (range 5.9-19.6%). Conversely, only 5.0% of patients had objective frailty, with minimal variability (range 4.5-6.7%); and only <1% of patients were identified as frail by both approaches. Compared with non-frailty-perceived, perceived frail patients were older, more frequently female, and with lower body weight; conversely, objectively frail patients had more comorbidities. Non-recommended edoxaban dose regimens were more frequently prescribed in both frail patient categories. CONCLUSIONS: Physicians' perception of frailty in AF patients is variable, mainly driven by age, sex, and weight, and quite different compared with the results of an objective frailty assessment. Whatever the approach, frailty appears to be associated with non-recommended anticoagulant dosages. Whether this apparent inappropriateness influences hard outcomes remains to be assessed.


Assuntos
Fibrilação Atrial , Fragilidade , Acidente Vascular Cerebral , Administração Oral , Anticoagulantes , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/epidemiologia , Europa (Continente)/epidemiologia , Feminino , Fragilidade/diagnóstico , Fragilidade/epidemiologia , Humanos , Estudos Prospectivos , Piridinas , Acidente Vascular Cerebral/epidemiologia , Tiazóis
12.
Pacing Clin Electrophysiol ; 45(2): 262-269, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34927271

RESUMO

Cardiac implantable electronic device (CIED) infection represents a dramatic event with a high mortality rate (>3x) despite antibiotic therapy and device extraction; therefore, the real winning strategy in this situation could be represented by prevention. Antibiotic prophylaxis and antibiotic-releasing envelope are effective in improving patient outcome; however, healthcare costs related to CIED infections remain high over the years. In this review we would keep the attention on a pre-surgical checklist to reduce the risk of CIED infections. In fact, checklist is an effective instrument for medical care quality improvement mainly used in surgery, but not very commonly in cath-lab and electrophysiology procedures. All steps of this checklist are of proven effectiveness in reducing the risk of CIED infections but, up till now, they are not considered together in a pre-surgical approach.


Assuntos
Lista de Checagem , Desfibriladores Implantáveis , Marca-Passo Artificial , Infecções Relacionadas à Prótese/prevenção & controle , Antibioticoprofilaxia , Humanos , Período Pré-Operatório
13.
J Cardiovasc Electrophysiol ; 32(2): 468-476, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33296533

RESUMO

BACKGROUND: Current guidelines recommend defibrillation testing (DT) performance in patients with a subcutaneous implantable cardioverter defibrillator (S-ICD), theoretically to reduce the amount of ineffective shocks. DT, however, has been proven unnecessary in transvenous ICD and real-world data show a growing trend in avoidance of DT after S-ICD implantation. METHODS: All patients undergoing S-ICD implant at nine associated Italian centers joining in the ELISIR registry (ClinicalTrials.gov Identifier: NCT04373876) were enrolled and classified upon DT performance. Long-term follow-up events were recorded and compared to report the long-term efficacy and safety of S-ICD implantations without DT in a real-world setting. RESULTS: A total of 420 patients (54.0 ± 15.5 years, 80.0% male) were enrolled in the study. A DT was performed in 254 (60.5%) patients (DT+ group), while in 166 (39.5%) was avoided (DT- group). Over a median follow-up of 19 (11-31) months, a very low rate (0.7%) of ineffective shocks was observed, and no significant differences in the primary combined arrhythmic outcome were observed between the two groups (p = .656). At regression analysis, the only clinical predictor associated with the primary combined outcome was S-ICD placement for primary prevention (odds ratio: 0.42; p = .013); DT performance instead was not associated with a reduction in primary outcome (p = .375). CONCLUSION: Implanting an S-ICD without DT does not appear to impact the safety of defibrillation therapy and overall patients' survival.


Assuntos
Desfibriladores Implantáveis , Adulto , Idoso , Cardioversão Elétrica , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Resultado do Tratamento
14.
Europace ; 23(10): 1577-1585, 2021 10 09.
Artigo em Inglês | MEDLINE | ID: mdl-34322707

RESUMO

AIMS: Cardiac resynchronization therapy (CRT) upgrades may be less likely to improve following intervention. Leadless left ventricular (LV) endocardial pacing has been used for patients with previously failed CRT or high-risk upgrades. We compared procedural and long-term outcomes in patients undergoing coronary sinus (CS) CRT upgrades with high-risk and previously failed CRT upgrades undergoing LV endocardial upgrades. METHOD AND RESULTS: Prospective consecutive CS upgrades between 2015 and 2019 were compared with those undergoing WiSE-CRT implantation. Cardiac resynchronization therapy response at 6 months was defined as improvement in clinical composite score (CCS) and a reduction in LV end-systolic volume (LVESV) ≥15%. A total of 225 patients were analysed; 121 CS and 104 endocardial upgrades. Patients receiving WiSE-CRT tended to have more comorbidities and were more likely to have previous cardiac surgery (30.9% vs. 16.5%; P = 0.012), hypertension (59.2% vs. 34.7%; P < 0.001), chronic obstructive airways disease (19.4% vs. 9.9%; P = 0.046), and chronic kidney disease (46.4% vs. 21.5%; P < 0.01) but similar LV ejection fraction (30.0 ± 8.3% vs. 29.5 ± 8.6%; P = 0.678). WiSE-CRT upgrades were successful in 97.1% with procedure-related mortality in 1.9%. Coronary sinus upgrades were successful in 97.5% of cases with a 2.5% rate of CS dissection and 5.6% lead malfunction/displacement. At 6 months, 91 WiSE-CRT upgrades and 107 CS upgrades had similar improvements in CCS (76.3% vs. 68.5%; P = 0.210) and reduction in LVESV ≥15% (54.2% vs. 56.3%; P = 0.835). CONCLUSION: Despite prior failed upgrades and high-risk patients with more comorbidities, WiSE-CRT upgrades had high rates of procedural success and similar improvements in CCS and LV remodelling with CS upgrades.


Assuntos
Terapia de Ressincronização Cardíaca , Seio Coronário , Insuficiência Cardíaca , Seio Coronário/diagnóstico por imagem , Endocárdio , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Humanos , Estudos Prospectivos , Resultado do Tratamento
15.
Pacing Clin Electrophysiol ; 44(11): 1884-1889, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34498758

RESUMO

AIMS AND METHODS: In case of cardiacimplantable electronicdevice (CIED)-related infections, it is mandatory to completely remove the device and administer prolonged antibiotic therapy. The management of patients explanted for an implantable defibrillator (ICD) infection is complex especially in patients needing anti-bradycardia pacing or tachyarrhythmia protection. We tested the efficacy and safety of a conventional ICD externally connected to a transvenous dual-coil lead as bridging therapy before the reimplant, comparing outcomes with a historical cohort of patients (N = 113) treated with temporary transvenous pacing. We enrolled 18 patients explanted for ICD infection and needing prolonged antibiotic therapy in three high-volume Italian centers. They received an external ICD stand-by for a mean of 16.5 (4-30) days before the reimplant. RESULTS: No patient experienced malfunction of the system, with a significant reduction of this complication versus temporary transfemoral pacing (37%, p = .004). Post-procedural occurrence of other complications (infection, relevant local bleeding, ventricular tachycardia during insertion of the lead, cardiac perforation, and venous thromboembolism) was low and not different in the two groups. One patient experienced an electrical storm, effectively recognized by the external ICD and treated with anti-tachycardia pacings (ATPs) and shocks. CONCLUSIONS: An approach with an external ICD seems to be a safe and viable option as bridging therapy in patients requiring ICD explant for CIED infection.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/terapia , Idoso , Antibacterianos/uso terapêutico , Remoção de Dispositivo , Falha de Equipamento , Feminino , Humanos , Itália , Masculino , Fatores de Risco
16.
J Cardiovasc Electrophysiol ; 31(1): 144-149, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31778266

RESUMO

BACKGROUND: A two-incision technique, in association with inter-muscular positioning of the subcutaneous defibrillator (S-ICD), is now the most frequently adopted implantation approach in Europe. Ultrasound-guided serratus anterior plane block (SAPB) has been proposed to provide anesthesia/analgesia during S-ICD implantation. OBJECTIVE: We performed a case-control analysis in which a standardized SAPB approach was compared with the typical local anesthesia and sedation approach. METHODS: Ninety-one consecutive patients underwent implantation of an S-ICD with the SAPB approach for anesthesia/analgesia at 10 centers. The control group consisted of 55 consecutive patients who underwent S-ICD implantation with a standard local approach. RESULTS: The mean procedure duration was 59 ± 15 minutes in the SAPB group and 76 ± 23 minutes in the control group (P < .001). No operative complications were reported in either group. During the procedure, 79 (87%) patients in the SAPB group and 25 (46%) patients in the control group (P < .001) remained awake. Lower values of pain intensity at the device pocket (P = .005) and the lateral tunneling site (P = .046) were reported in the SAPB group. The difference in static (P = .002) and dynamic (P = .007) pain intensity between the groups persisted at 1 hour, while no differences were observed 6 hours after the end of the procedure. CONCLUSIONS: SAPB is feasible and effective in providing anesthesia/analgesia during S-ICD implantation. The procedures were successfully accomplished and no complications occurred in either group. However, SAPB was associated with lower pain levels, enabling the need for sedation to be reduced and more patients to remain awake. Moreover, it resulted in shorter procedure durations.


Assuntos
Desfibriladores Implantáveis , Cardioversão Elétrica/instrumentação , Músculo Esquelético/inervação , Bloqueio Nervoso , Dor Pós-Operatória/prevenção & controle , Implantação de Prótese/instrumentação , Adulto , Idoso , Estudos de Casos e Controles , Cardioversão Elétrica/efeitos adversos , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Bloqueio Nervoso/efeitos adversos , Duração da Cirurgia , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Estudos Prospectivos , Implantação de Prótese/efeitos adversos , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
17.
Europace ; 22(12): 1822-1829, 2020 12 23.
Artigo em Inglês | MEDLINE | ID: mdl-33118017

RESUMO

AIMS: The traditional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation involves three incisions and a subcutaneous pocket. Recently, a two-incision and intermuscular (IM) technique has been adopted. The PRAETORIAN score is a chest radiograph-based tool that predicts S-ICD conversion testing. We assessed whether the S-ICD implantation technique affects optimal position of the defibrillation system according to the PRAETORIAN score. METHODS AND RESULTS: We analysed consecutive patients undergoing S-ICD implantation. The χ2 test and regression analysis were used to determine the association between the PRAETORIAN score and implantation technique. Two hundred and thirteen patients were enrolled. The S-ICD generator was positioned in an IM pocket in 174 patients (81.7%) and the two-incision approach was adopted in 199 (93.4%). According to the PRAETORIAN score, the risk of conversion failure was classified as low in 198 patients (93.0%), intermediate in 13 (6.1%), and high in 2 (0.9%). Patients undergoing the two-incision and IM technique were more likely to have a low (<90) PRAETORIAN score than those undergoing the three-incision and subcutaneous technique (two-incision: 94.0% vs. three-incision: 78.6%; P = 0.004 and IM: 96.0% vs. subcutaneous: 79.5%; P = 0.001). Intermuscular plus two-incision technique was associated with a low-risk PRAETORIAN score (hazard ratio 3.76; 95% confidence interval 1.01-14.02; P = 0.04). Shock impedance was lower in PRAETORIAN low-risk patients than in intermediate-/high-risk categories (66 vs. 96 Ohm; P = 0.001). The PRAETORIAN score did not predict shock failure at 65 J. CONCLUSION: In this cohort of S-ICD recipients, combining the two-incision technique and IM generator implantation yielded the lowest PRAETORIAN score values, indicating optimal defibrillation system position. CLINICAL TRIAL REGISTRATION: http://clinicaltrials.gov/ Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Estudos de Coortes , Impedância Elétrica , Humanos , Implantação de Prótese/efeitos adversos , Fatores de Risco
18.
Curr Heart Fail Rep ; 17(6): 365-383, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33025463

RESUMO

PURPOSE OF REVIEW: Cardiotoxicity by anticancer agents has emerged as a multifaceted issue and is expected to affect both mortality and morbidity. This review summarizes clinical challenges in the management of oncological patients requiring anticoagulants for atrial fibrillation (AF) also considering the current outbreak of the COVID-19 (coronavirus disease 2019) pandemic, since this infection can add challenges to the management of both conditions. Specifically, the aims are manyfold: (1) describe the evolving use of direct oral anticoagulants (DOACs) in AF patients with cancer; (2) critically appraise the risk of clinically important drug-drug interactions (DDIs) between DOACs and oral targeted anticancer agents; (3) address expected DDIs between DOACs and candidate anti-COVID drugs, with implications on management of the underlying thrombotic risk; and (4) characterize the proarrhythmic liability in cardio-oncology in the setting of COVID-19, focusing on QT prolongation. RECENT FINDINGS: AF in cardio-oncology poses diagnostic and management challenges, also due to the number of anticancer drugs recently associated with AF onset/worsening. Oral targeted drugs can potentially interact with DOACs, with increased bleeding risk mainly due to pharmacokinetic DDIs. Moreover, the vast majority of oral anticancer agents cause QT prolongation with direct and indirect mechanisms, potentially resulting in the occurrence of torsade de pointes, especially in susceptible patients with COVID-19 receiving additional drugs with QT liability. Oncologists and cardiologists must be aware of the increased bleeding risk and arrhythmic susceptibility of patients with AF and cancer due to DDIs. High-risk individuals with COVID-19 should be prioritized to target preventive strategies, including optimal antithrombotic management, medication review, and stringent monitoring.


Assuntos
Antineoplásicos/efeitos adversos , Arritmias Cardíacas/induzido quimicamente , Fibrilação Atrial/tratamento farmacológico , Tratamento Farmacológico da COVID-19 , Inibidores do Fator Xa/efeitos adversos , Hemorragia/induzido quimicamente , Neoplasias/tratamento farmacológico , Tromboembolia/prevenção & controle , Fibrilação Atrial/complicações , COVID-19/complicações , Inibidores das Enzimas do Citocromo P-450/efeitos adversos , Sistema Enzimático do Citocromo P-450 , Interações Medicamentosas , Humanos , Síndrome do QT Longo/induzido quimicamente , Neoplasias/complicações , Tromboembolia/etiologia
19.
Eur J Nucl Med Mol Imaging ; 46(1): 194-205, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-30196365

RESUMO

PURPOSE: 18F-FDG PET/CT is an emerging technique for diagnosis of cardiac implantable electronic devices infection (CIEDI). Despite the improvements in transvenous lead extraction (TLE), long-term survival in patients with CIEDI is poor. The aim of the present study was to evaluate whether the extension of CIEDI at 18F-FDG PET/CT can improve prediction of survival after TLE. METHODS: Prospective, monocentric observational study enrolling consecutive candidates to TLE for a diagnosis of CIEDI. 18F-FDG PET/CT was performed in all patients prior TLE. RESULTS: There were 105 consecutive patients with confirmed CIEDI enrolled. An increased 18F-FDG uptake was limited to cardiac implantable electrical device (CIED) pocket in 56 patients, 40 patients had a systemic involvement. We had nine negative PET in patients undergoing prolonged antimicrobial therapy (22.5 ± 14.0 days vs. 8.6 ± 13.0 days; p = 0.005). Implementation of 18F-FDG PET/CT in modified Duke Criteria lead to reclassification of 23.8% of the patients. After a mean follow-up of 25.0 ± 9.0 months, 31 patients died (29.5%). Patients with CIED pocket involvement at 18F-FDG PET/CT presented a better survival independently of presence/absence of systemic involvement (HR 0.493, 95%CI 0.240-0.984; p = 0.048). After integration of 18F-FDG PET/CT data, absence of overt/hidden pocket involvement in CIEDI and a (glomerular filtration rate) GFR < 60 ml/min were the only independent predictors of mortality at long term. CONCLUSIONS: Patient with CIEDI and a Cold Closed Pocket (i.e., a CIED pocket without skin erosion/perforation nor increased capitation at 18F-FDG PET/CT) present worse long-term survival. Patient management can benefit by systematic adoption of pre-TLE 18F-FDG PET/CT through improved identification of CIED related endocarditis (CIEDIE) and hidden involvement of CIED pocket.


Assuntos
Desfibriladores Implantáveis/efeitos adversos , Endocardite Bacteriana/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/normas , Infecções Relacionadas à Prótese/diagnóstico por imagem , Idoso , Endocardite Bacteriana/epidemiologia , Endocardite Bacteriana/etiologia , Feminino , Fluordesoxiglucose F18 , Humanos , Masculino , Mortalidade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Infecções Relacionadas à Prótese/epidemiologia , Compostos Radiofarmacêuticos
20.
J Nucl Cardiol ; 26(1): 123-132, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28667454

RESUMO

AIM: We carried out this study to investigate mid-term effects of cardiac resynchronization therapy (CRT) on right ventricular (RV) function and neurohormonal response, expressed by N-terminal pro-brain natriuretic peptide (NT-proBNP), in heart failure patients stratified by baseline RV ejection fraction (RVEF). METHODS AND RESULTS: Thirty-six patients with nonischemic dilated cardiomyopathy underwent technetium-99m radionuclide angiography with bicycle exercise immediately after CRT implantation (during spontaneous rhythm and after CRT activation) and 3 months later. Plasma NT proBNP was assessed before implantation and after 3 months. At baseline, RVEF was impaired (≤35%) in 14 patients, preserved (>35%) in 22. At 3 months, RVEF improved during rest and exercise (P = .02) in patients with impaired RV function, while remaining unchanged in patients with preserved RV function. Rest and exercise RV dyssynchrony decreased in both groups at follow-up (P < .05). A similar mid-term improvement in left ventricular (LV) function and NT-proBNP was observed in patients with impaired and preserved RVEF. In the former, the decrease in NT-proBNP correlated with the improvements both in LV and RV dyssynchrony and functions. CONCLUSION: CRT may improve RV performance, during rest and exercise, and neurohormonal response in heart failure patients with nonischemic dilated cardiomyopathy and baseline RV dysfunction. RV dysfunction should not be considered per se a primary criterion for excluding candidacy to CRT.


Assuntos
Terapia de Ressincronização Cardíaca , Cardiomiopatias/diagnóstico por imagem , Insuficiência Cardíaca/fisiopatologia , Função Ventricular Direita , Idoso , Exercício Físico , Feminino , Análise de Fourier , Humanos , Masculino , Pessoa de Meia-Idade , Peptídeo Natriurético Encefálico/farmacologia , Fragmentos de Peptídeos/farmacologia , Estudos Prospectivos , Angiografia Cintilográfica , Projetos de Pesquisa , Descanso , Tecnécio , Disfunção Ventricular Direita
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA