1.
J Appl Clin Med Phys ; 24(3): e13909, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36680744

RESUMO

BACKGROUND: Rapid kV cone-beam computed tomography (CBCT) scans are achievable in under 20 s on select linear accelerator systems to generate volumetric images in three dimensions (3D). Daily pre-treatment four-dimensional CBCT (4DCBCT) is recommended in image-guided lung radiotherapy to mitigate the detrimental effects of respiratory motion on treatment quality. PURPOSE: To demonstrate the potential for thoracic 4DCBCT reconstruction using projection data that was simulated using a clinical rapid 3DCBCT acquisition protocol. METHODS: We simulated conventional (1320 projections over 4 min) and rapid (491 projections over 16.6 s) CBCT acquisitions using 4D computed tomography (CT) volumes of 14 lung cancer patients. Conventional acquisition data were reconstructed using the 4D Feldkamp-Davis-Kress (FDK) algorithm. Rapid acquisition data were reconstructed using 3DFDK, 4DFDK, and Motion-Compensated FDK (MCFDK). Image quality was evaluated using Contrast-to-Noise Ratio (CNR), Tissue Interface Width (TIW), Root-Mean-Square Error (RMSE), and Structural SIMilarity (SSIM). RESULTS: The conventional acquisition 4DFDK reconstructions had median phase averaged CNR, TIW, RMSE, and SSIM of 2.96, 8.02 mm, 83.5, and 0.54, respectively. The rapid acquisition 3DFDK reconstructions had median CNR, TIW, RMSE, and SSIM of 2.99, 13.6 mm, 112, and 0.44 respectively. The rapid acquisition MCFDK reconstructions had median phase averaged CNR, TIW, RMSE, and SSIM of 2.98, 10.2 mm, 103, and 0.46, respectively. Rapid acquisition 4DFDK reconstruction quality was insufficient for any practical use due to sparse angular projection sampling. CONCLUSIONS: Results suggest that 4D motion-compensated reconstruction of rapid acquisition thoracic CBCT data are feasible with image quality approaching conventional acquisition CBCT data reconstructed using standard 4DFDK.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador , Humanos , Imagens de Fantasmas , Processamento de Imagem Assistida por Computador/métodos , Movimento (Física) , Simulação por Computador , Tomografia Computadorizada de Feixe Cônico/métodos , Algoritmos , Tomografia Computadorizada Quadridimensional/métodos
2.
Med Phys ; 51(2): 1364-1382, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-37427751

RESUMO

BACKGROUND: The adoption of four-dimensional cone beam computed tomography (4DCBCT) for image-guided lung cancer radiotherapy is increasing, especially for hypofractionated treatments. However, the drawbacks of 4DCBCT include long scan times (∼240 s), inconsistent image quality, higher imaging dose than necessary, and streaking artifacts. With the emergence of linear accelerators that can acquire 4DCBCT scans in a short period of time (9.2 s) there is a need to examine the impact that these very fast gantry rotations have on 4DCBCT image quality. PURPOSE: This study investigates the impact of gantry velocity and angular separation between x-ray projections on image quality and its implication for fast low-dose 4DCBCT with emerging systems, such as the Varian Halcyon that provide fast gantry rotation and imaging. Large and uneven angular separation between x-ray projections is known to reduce 4DCBCT image quality through increased streaking artifacts. However, it is not known when angular separation starts degrading image quality. The study assesses the impact of constant and adaptive gantry velocity and determines the level when angular gaps impair image quality using state-of-the-art reconstruction methods. METHODS: This study considers fast low-dose 4DCBCT acquisitions (60-80 s, 200-projection scans). To assess the impact of adaptive gantry rotations, the angular position of x-ray projections from adaptive 4DCBCT acquisitions from a 30-patient clinical trial were analyzed (referred to as patient angular gaps). To assess the impact of angular gaps, variable and static angular gaps (20°, 30°, 40°) were introduced into evenly separated 200 projections (ideal angular separation). To simulate fast gantry rotations, which are on emerging linacs, constant gantry velocity acquisitions (9.2 s, 60 s, 120 s, 240 s) were simulated by sampling x-ray projections at constant intervals using the patient breathing traces from the ADAPT clinical trial (ACTRN12618001440213). The 4D Extended Cardiac-Torso (XCAT) digital phantom was used to simulate projections to remove patient-specific image quality variables. Image reconstruction was performed using Feldkamp-Davis-Kress (FDK), McKinnon-Bates (MKB), and Motion-Compensated-MKB (MCMKB) algorithms. Image quality was assessed using Structural Similarity-Index-Measure (SSIM), Contrast-to-Noise-Ratio (CNR), Signal-to-Noise-Ratio (SNR), Tissue-Interface-Width-Diaphragm (TIW-D), and Tissue-Interface-Width-Tumor (TIW-T). RESULTS: Patient angular gaps and variable angular gap reconstructions produced similar results to ideal angular separation reconstructions, while static angular gap reconstructions produced lower image quality metrics. For MCMKB-reconstructions, average patient angular gaps produced SSIM-0.98, CNR-13.6, SNR-34.8, TIW-D-1.5 mm, and TIW-T-2.0 mm, static angular gap 40° produced SSIM-0.92, CNR-6.8, SNR-6.7, TIW-D-5.7 mm, and TIW-T-5.9 mm and ideal produced SSIM-1.00, CNR-13.6, SNR-34.8, TIW-D-1.5 mm, and TIW-T-2.0 mm. All constant gantry velocity reconstructions produced lower image quality metrics than ideal angular separation reconstructions regardless of the acquisition time. Motion compensated reconstruction (MCMKB) produced the highest contrast images with low streaking artifacts. CONCLUSION: Very fast 4DCBCT scans can be acquired provided that the entire scan range is adaptively sampled, and motion-compensated reconstruction is performed. Importantly, the angular separation between x-ray projections within each individual respiratory bin had minimal effect on the image quality of fast low-dose 4DCBCT imaging. The results will assist the development of future 4DCBCT acquisition protocols that can now be achieved in very short time frames with emerging linear accelerators.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Técnicas de Imagem de Sincronização Respiratória , Humanos , Tomografia Computadorizada de Feixe Cônico/métodos , Tomografia Computadorizada Quadridimensional/métodos , Imagens de Fantasmas , Razão Sinal-Ruído , Técnicas de Imagem de Sincronização Respiratória/métodos , Processamento de Imagem Assistida por Computador/métodos , Algoritmos
3.
Sci Rep ; 13(1): 9776, 2023 06 16.
Artigo em Inglês | MEDLINE | ID: mdl-37328551

RESUMO

This work presents a novel hardware configuration for radiotherapy systems to enable fast 3D X-ray imaging before and during treatment delivery. Standard external beam radiotherapy linear accelerators (linacs) have a single X-ray source and detector located at ± 90° from the treatment beam respectively. The entire system can be rotated around the patient acquiring multiple 2D X-ray images to create a 3D cone-beam Computed Tomography (CBCT) image before treatment delivery to ensure the tumour and surrounding organs align with the treatment plan. Scanning with a single source is slow relative to patient respiration or breath holds and cannot be performed during treatment delivery, limiting treatment delivery accuracy in the presence of patient motion and excluding some patients from concentrated treatment plans that would be otherwise expected to have improved outcomes. This simulation study investigated whether recent advances in carbon nanotube (CNT) field emission source arrays, high frame rate (60 Hz) flat panel detectors and compressed sensing reconstruction algorithms could circumvent imaging limitations of current linacs. We investigated a novel hardware configuration incorporating source arrays and high frame rate detectors into an otherwise standard linac. We investigated four potential pre-treatment scan protocols that could be achieved in a 17 s breath hold or 2-10 1 s breath holds. Finally, we demonstrated for the first time volumetric X-ray imaging during treatment delivery by using source arrays, high frame rate detectors and compressed sensing. Image quality was assessed quantitatively over the CBCT geometric field of view as well as across each axis through the tumour centroid. Our results demonstrate that source array imaging enables larger volumes to be imaged with acquisitions as short as 1 s albeit with reduced image quality arising from lower photon flux and shorter imaging arcs.


Assuntos
Algoritmos , Neoplasias , Humanos , Raios X , Imagens de Fantasmas , Tomografia Computadorizada de Feixe Cônico/métodos , Neoplasias/diagnóstico por imagem , Neoplasias/radioterapia
4.
Med Phys ; 50(4): 2372-2379, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36681083

RESUMO

BACKGROUND: The clinical benefits of intraoperative cone beam CT (CBCT) during orthopedic procedures include (1) improved accuracy for procedures involving the placement of hardware and (2) providing immediate surgical verification. PURPOSE: Orthopedic interventions often involve long and wide anatomical sites (e.g., lower extremities). Therefore, in order to ensure that the clinical benefits are available to all orthopedic procedures, we investigate the feasibility of a novel imaging trajectory to simultaneously expand the CBCT field-of-view longitudinally and laterally. METHODS: A continuous dual-isocenter imaging trajectory was implemented on a clinical robotic CBCT system using additional real-time control hardware. The trajectory consisted of 200° circular arcs separated by alternating lateral and longitudinal table translations. Due to hardware constraints, the direction of rotation (clockwise/anticlockwise) and lateral table translation (left/right) was reversed every 400°. X-ray projections were continuously acquired at 15 frames/s throughout all movements. A whole-body phantom was used to verify the trajectory. As comparator, a series of conventional large volume acquisitions were stitched together. Image quality was quantified using Root Mean Square Deviation (RMSD), Mean Absolute Percentage Deviation (MAPD), Structural Similarity Index Metric (SSIM) and Contrast-to-Noise Ratio (CNR). RESULTS: The imaging volume produced by the continuous dual-isocenter trajectory had dimensions of L = 95 cm × W = 45 cm × H = 45 cm. This enabled the hips to the feet of the whole-body phantom to be captured in approximately half the imaging dose and acquisition time of the 11 stitched conventional acquisitions required to match the longitudinal and lateral imaging dimensions. Compared to the stitched conventional images, the continuous dual-isocenter acquisition had RMSD of 4.84, MAPD of 6.58% and SSIM of 0.99. The CNR of the continuous dual-isocenter and stitched conventional acquisitions were 1.998 and 1.999, respectively. CONCLUSION: Extended longitudinal and lateral intraoperative volumetric imaging is feasible on clinical robotic CBCT systems.


Assuntos
Imageamento Tridimensional , Tomografia Computadorizada de Feixe Cônico Espiral , Tomografia Computadorizada de Feixe Cônico/métodos , Imagens de Fantasmas , Cintilografia
5.
Phys Med Biol ; 67(6)2022 03 07.
Artigo em Inglês | MEDLINE | ID: mdl-35172286

RESUMO

This study investigates the dose and time limits of adaptive 4DCBCT acquisitions (adaptive-acquisition) compared with current conventional 4DCBCT acquisition (conventional-acquisition). We investigate adaptive-acquisitions as low as 60 projections (∼25 s scan, 6 projections per respiratory phase) in conjunction with emerging image reconstruction methods. 4DCBCT images from 20 patients recruited into the adaptive CT acquisition for personalized thoracic imaging clinical study (NCT04070586) were resampled to simulate faster and lower imaging dose acquisitions. All acquisitions were reconstructed using Feldkamp-Davis-Kress (FDK), McKinnon-Bates (MKB), motion compensated FDK (MCFDK), motion compensated MKB (MCMKB) and simultaneous motion estimation and image reconstruction (SMEIR) algorithms. All reconstructions were compared against conventional-acquisition 4DFDK-reconstruction using Structural SIMilarity Index (SSIM), signal-to-noise ratio (SNR), contrast-to-noise-ratio (CNR), tissue interface sharpness diaphragm (TIS-D), tissue interface sharpness tumor (TIS-T) and center of mass trajectory (COMT) for difference in diaphragm and tumor motion. All reconstruction methods using 110-projection adaptive-acquisition (11 projections per respiratory phase) had a SSIM of greater than 0.92 relative to conventional-acquisition 4DFDK-reconstruction. Relative to conventional-acquisition 4DFDK-reconstruction, 110-projection adaptive-acquisition MCFDK-reconstructions images had 60% higher SNR, 10% higher CNR, 30% higher TIS-T and 45% higher TIS-D on average. The 110-projection adaptive-acquisition SMEIR-reconstruction images had 123% higher SNR, 90% higher CNR, 96% higher TIS-T and 60% higher TIS-D on average. The difference in diaphragm and tumor motion compared to conventional-acquisition 4DFDK-reconstruction was within submillimeter accuracy for all acquisition reconstruction methods. Adaptive-acquisitions resulted in faster scans with lower imaging dose and equivalent or improved image quality compared to conventional-acquisition. Adaptive-acquisition with motion compensated-reconstruction enabled scans with as low as 110 projections to deliver acceptable image quality. This translates into 92% lower imaging dose and 80% less scan time than conventional-acquisition.


Assuntos
Diagnóstico por Imagem , Tórax , Diafragma/diagnóstico por imagem , Humanos , Movimento (Física) , Razão Sinal-Ruído
6.
Artigo em Inglês | MEDLINE | ID: mdl-38187806

RESUMO

Non-circular orbits in cone-beam CT (CBCT) imaging are increasingly being studied for potential benefits in field-of-view, dose reduction, improved image quality, minimal interference in guided procedures, metal artifact reduction, and more. While modern imaging systems such as robotic C-arms are enabling more freedom in potential orbit designs, practical implementation on such clinical systems remains challenging due to obstacles in critical stages of the workflow, including orbit realization, geometric calibration, and reconstruction. In this work, we build upon previous successes in clinical implementation and address key challenges in the geometric calibration stage with a novel calibration method. The resulting workflow eliminates the need for prior patient scans or dedicated calibration phantoms, and can be conducted in clinically relevant processing times.

7.
Invest Radiol ; 57(11): 764-772, 2022 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-35510875

RESUMO

OBJECTIVES: Cone beam computed tomography (CBCT) imaging is becoming an indispensable intraoperative tool; however, the current field of view prevents visualization of long anatomical sites, limiting clinical utility. Here, we demonstrate the longitudinal extension of the intraoperative CBCT field of view using a multi-turn reverse helical scan and assess potential clinical utility in interventional procedures. MATERIALS AND METHODS: A fixed-room robotic CBCT imaging system, with additional real-time control, was used to implement a multi-turn reverse helical scan. The scan consists of C-arm rotation, through a series of clockwise and anticlockwise rotations, combined with simultaneous programmed table translation. The motion properties and geometric accuracy of the multi-turn reverse helical imaging trajectory were examined using a simple geometric phantom. To assess potential clinical utility, a pedicle screw posterior fixation procedure in the thoracic spine from T1 to T12 was performed on an ovine cadaver. The multi-turn reverse helical scan was used to provide postoperative assessment of the screw insertion via cortical breach grading and mean screw angle error measurements (axial and sagittal) from 2 observers. For all screw angle measurements, the intraclass correlation coefficient was calculated to determine observer reliability. RESULTS: The multi-turn reverse helical scans took 100 seconds to complete and increased the longitudinal coverage by 370% from 17 cm to 80 cm. Geometric accuracy was examined by comparing the measured to actual dimensions (0.2 ± 0.1 mm) and angles (0.2 ± 0.1 degrees) of a simple geometric phantom, indicating that the multi-turn reverse helical scan provided submillimeter and degree accuracy with no distortion. During the pedicle screw procedure in an ovine cadaver, the multi-turn reverse helical scan identified 4 cortical breaches, confirmed via the postoperative CT scan. Directly comparing the screw insertion angles (n = 22) measured in the postoperative multi-turn reverse helical and CT scans revealed an average difference of 3.3 ± 2.6 degrees in axial angle and 1.9 ± 1.5 degrees in the sagittal angle from 2 expert observers. The intraclass correlation coefficient was above 0.900 for all measurements (axial and sagittal) across all scan types (conventional CT, multi-turn reverse helical, and conventional CBCT), indicating excellent reliability between observers. CONCLUSIONS: Extended longitudinal field-of-view intraoperative 3-dimensional imaging with a multi-turn reverse helical scan is feasible on a clinical robotic CBCT imaging system, enabling long anatomical sites to be visualized in a single image, including in the presence of metal hardware.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada por Raios X , Animais , Cadáver , Tomografia Computadorizada de Feixe Cônico/métodos , Humanos , Imagens de Fantasmas , Reprodutibilidade dos Testes , Ovinos , Tomografia Computadorizada por Raios X/métodos
8.
Med Phys ; 48(5): 2543-2552, 2021 May.
Artigo em Inglês | MEDLINE | ID: mdl-33651409

RESUMO

PURPOSE: An important factor when considering the use of interventional cone beam computed tomography (CBCT) imaging during cardiac procedures is the trade-off between imaging dose and image quality. Accordingly, Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) presents an alternative acquisition method, adapting the gantry velocity and projection rate of CBCT imaging systems in accordance with a patient's electrocardiogram (ECG) signal in real-time. The aim of this study was to experimentally investigate that ACROBEAT acquisitions deliver improved image quality compared to conventional cardiac CBCT imaging protocols with fewer projections acquired. METHODS: The Siemens ARTIS pheno (Siemens Healthcare, GmbH, Germany), a robotic CBCT C-arm system, was used to compare ACROBEAT with a commercially available conventional cardiac imaging protocol that utilizes multisweep retrospective ECG-gated acquisition. For ACROBEAT, real-time control of the gantry position was enabled through the Siemens Test Automation Control system. ACROBEAT and conventional image acquisitions of the CIRS Dynamic Cardiac Phantom were performed, using five patient-measured ECG traces. The traces had average heart rates of 56, 64, 76, 86, and 100 bpm. The total number of acquired projections was compared between the ACROBEAT and conventional acquisition methods. The image quality was assessed via the contrast-to-noise ratio (CNR), structural similarity index (SSIM), and root-mean square error (RMSE). RESULTS: Compared to the conventional protocol, ACROBEAT reduced the total number of projections acquired by 90%. The visual image quality provided by the ACROBEAT acquisitions, across all traces, matched or improved compared to conventional acquisition and was independent of the patient's heart rate. Across all traces, ACROBEAT averaged 1.4 times increase in the CNR, a 23% increase in the SSIM and a 29% decrease in the RMSE compared to conventional and was independent of the patient's heart rate. CONCLUSION: Adaptive patient imaging is feasible on a clinical robotic CBCT system, delivering higher quality images while reducing the number of projections acquired by 90% compared to conventional cardiac imaging protocols.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Coração , Alemanha , Coração/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Estudos Retrospectivos
9.
Radiother Oncol ; 161: 29-34, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34052341

RESUMO

BACKGROUND AND PURPOSE: We present the first implementation of Adaptive 4D cone beam CT (4DCBCT) that adapts the image hardware (gantry rotation speed and kV projections) in response to the patient's real-time respiratory signal. Adaptive 4DCBCT was applied on lung cancer patients to reduce the scan time and imaging dose in the ADaptive CT Acquisition for Personalised Thoracic imaging (ADAPT) trial. MATERIALS AND METHODS: The ADAPT technology measures the patient's real-time respiratory signal and uses mathematical optimisation and external circuitry attached to the linear accelerator to modulate the gantry rotation speed and kV projection rate to reduce scan times and imaging dose. For each patient, ADAPT scans were acquired on two treatment fractions and reconstructed with a motion compensated reconstruction algorithm and compared to the current state-of-the-art four-minute 4DCBCT acquisition (conventional 4DCBCT). We report on the scan time, imaging dose and image quality for the first four adaptive 4DCBCT patients. RESULTS: The ADAPT imaging dose was reduced by 85% and scan times were 73 ± 12 s representing a 70% reduction compared to the 240 s conventional 4DCBCT scan. The contrast-to-noise ratio was improved from 9.2 ± 3.9 with conventional 4DCBCT to 11.7 ± 4.1 with ADAPT. DISCUSSION: The ADAPT trial represents the first time that gantry rotation speed and projection acquisition have been adapted and optimised in real-time in response to changes in the patient's breathing. ADAPT demonstrates substantially reduced scan times and imaging dose for clinical 4DCBCT imaging that could enable more efficient and optimised lung cancer radiotherapy.


Assuntos
Tomografia Computadorizada Quadridimensional , Neoplasias Pulmonares , Algoritmos , Tomografia Computadorizada de Feixe Cônico , Humanos , Neoplasias Pulmonares/diagnóstico por imagem , Neoplasias Pulmonares/radioterapia , Aceleradores de Partículas , Imagens de Fantasmas , Respiração
10.
Phys Med Biol ; 66(10)2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33878747

RESUMO

Fixed-gantry radiation therapy has been proposed as a low-cost alternative to the conventional rotating-gantry radiation therapy, that may help meet the rising global treatment demand. Fixed-gantry systems require gravitational motion compensated reconstruction algorithms to produce cone-beam CT (CBCT) images of sufficient quality for image guidance. The aim of this work was to adapt and investigate five CBCT reconstruction algorithms for fixed-gantry CBCT images. The five algorithms investigated were Feldkamp-Davis-Kress (FDK), prior image constrained compressed sensing (PICCS), gravitational motion compensated FDK (GMCFDK), motion compensated PICCS (MCPICCS) (a novel CBCT reconstruction algorithm) and simultaneous motion estimation and iterative reconstruction (SMEIR). Fixed-gantry and rotating-gantry CBCT scans were acquired of 3 rabbits, with the rotating-gantry scans used as a reference. Projections were sorted into rotation bins, based on the angle of rotation of the rabbit during image acquisition. The algorithms were compared using the structural similarity index measure root mean square error, and reconstruction time. Evaluation of the reconstructed volumes showed that, when compared with the reference rotating-gantry volume, the conventional FDK algorithm did not accurately reconstruct fixed-gantry CBCT scans. Whilst the PICCS reconstruction algorithm reduced some motion artefacts, the motion estimation reconstruction methods (GMCFDK, MCPICCS and SMEIR) were able to greatly reduce the effect of motion artefacts on the reconstructed volumes. This finding was verified quantitatively, with GMCFDK, MCPICCS and SMEIR reconstructions having RMSE 17%-19% lower and SSIM 1% higher than a conventional FDK. However, all motion compensated fixed-gantry CBCT reconstructions had a 56%-61% higher RMSE and 1.5% lower SSIM than FDK reconstructions of conventional rotating-gantry CBCT scans. The results show that motion compensation is required to reduce motion artefacts for fixed-gantry CBCT reconstructions. This paper further demonstrates the feasibility of fixed-gantry CBCT scans, and the ability of CBCT reconstruction algorithms to compensate for motion due to horizontal rotation.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Algoritmos , Animais , Artefatos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Coelhos , Rotação
11.
Phys Med Biol ; 66(7)2021 03 23.
Artigo em Inglês | MEDLINE | ID: mdl-33662943

RESUMO

Conventional 4DCBCT captures 1320 projections across 4 min. Adaptive 4DCBCT has been developed to reduce imaging dose and scan time. This study investigated reconstruction algorithms that best complement adaptive 4DCBCT acquisition for reducing imaging dose and scan time whilst maintaining or improving image quality compared to conventional 4DCBCT acquisition using real patient data from the first 10 adaptive 4DCBCT patients. Adaptive 4DCBCT was implemented in the ADaptive CT Acquisition for Personalized Thoracic imaging clinical trial. Adaptive 4DCBCT modulates gantry rotation speed and kV acquisition rate in response to the patient's real-time respiratory signal, ensuring even angular spacing between projections at each respiratory phase. We examined the first 10 lung cancer radiotherapy patients that received adaptive 4DCBCT. Fast, 200-projection scans over 60-80 s, and slower, 600-projection scans over ∼240 s, were obtained after routine patient treatment and compared against conventional 4DCBCT acquisition. Adaptive 4DCBCT acquisitions were reconstructed using Feldkamp-Davis-Kress (FDK), McKinnon-Bates (MKB), Motion Compensated FDK (MCFDK) and Motion Compensated MKB (MCMKB) algorithms. Reconstructions were assessed via, Structural SIMilarity (SSIM), Signal-to-Noise-Ratio (SNR), Contrast-to-Noise-Ratio (CNR), Tissue Interface Sharpness of Diaphragm (TIS-D) and Tumor (TIS-T). The 200- and 600-projection adaptive 4DCBCT acquisition corresponded to 85% and 55% reduction in imaging dose, shorter and similar scan times of approximately 90 s and 236 s respectively, compared to conventional 4DCBCT acquisition. 200- and 600-projection adaptive 4DCBCT reconstructions achieved more than 0.900 SSIM relative to conventional 4DCBCT acquisition. Compared to conventional 4DCBCT acquisition, 200-projection adaptive 4DCBCT reconstructions achieved higher SNR, CNR, TIS-T, TIS-D with motion compensated algorithms, MCFDK (208%, 159%, 174%, 247%) and MCMKB (214%, 173%, 266%, 245%) respectively. The 200-projection adaptive 4DCBCT MCFDK- and MCMKB-reconstruction results show image quality improvements are possible even with 85% fewer projections acquired. We established acquisition-reconstruction protocols that provide substantial reductions in imaging time and dose whilst improving image quality.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Algoritmos , Humanos , Movimento (Física) , Imagens de Fantasmas , Razão Sinal-Ruído
12.
Phys Med Biol ; 65(17): 175009, 2020 08 31.
Artigo em Inglês | MEDLINE | ID: mdl-32485686

RESUMO

Conventional thoracic 4DCBCT scans take 1320 projections over 4 min. This paper investigates which reconstruction algorithms best leverage Respiratory-Motion-Guided (RMG) acquisition in order to reduce scan time and dose while maintaining image quality. We investigated a 200 projection, on average 1 min RMG acquisition. RMG acquisition ensures even angular separation between projections at each respiratory phase by adjusting the imaging gantry rotation to the patient respiratory signal in real time. Conventional 1320 projection data and RMG 200 projection data were simulated from 4DCT volumes of 14 patients. Each patient had an initial 4DCT reconstruction, treated as a planning 4DCT, and a 4DCT reconstruction acquired later, used for 4DCBCT data simulation and evaluation. Reconstructions were computed using the Feldkamp-David-Kress (FDK), McKinnon-Bates (MKB), RecOnstructiOn using Spatial and TEmporal Regularization (ROOSTER), and Motion Compensated FDK (MCFDK) algorithms. We also introduced and evaluated a novel MCMKB algorithm. Image quality was evaluated with Root-Mean-Square Error (RMSE), Structural SIMilarity index (SSIM) and Tissue Interface Sharpness (TIS). Rigid registration of the tumor volume regions between the reconstruction and the ground truth was used to evaluate geometric accuracy. Relative to conventional 4DCBCT acquisition, the RMG acquisition delivered 80% less dose and was on average 70% faster. The conventional-acquisition 4DFDK-reconstruction volumes had mean RMSE, SSIM, TIS and geometric error of 94, 0.9987, 2.69 and 1.19 mm respectively. The RMG-acquisition MCFDK-reconstruction volumes had mean RMSE, SSIM, TIS and geometric error of 113, 0.9986, 1.76 and 1.77 mm respectively with minimal increase in computational cost. These results suggest scan time and dose can be significantly reduced with minimal impact on reconstruction quality by implementing RMG acquisition and motion compensated reconstruction.


Assuntos
Algoritmos , Tomografia Computadorizada de Feixe Cônico , Processamento de Imagem Assistida por Computador/métodos , Movimento , Técnicas de Imagem de Sincronização Respiratória , Imagens de Fantasmas
13.
Med Phys ; 47(11): 5749-5760, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32969492

RESUMO

PURPOSE: Interventional treatments of aneurysms in the carotid artery are increasingly being supplemented with three-dimensional (3D) x-ray imaging. The 3D imaging provides additional information on device sizing and stent malapposition during the procedure. Standard 3D x-ray image acquisition is a one-size fits all model, exposing patients to additional radiation and results in images that may have cardiac-induced motion blur around the artery. Here, we investigate the potential of a novel dynamic imaging technique Adaptive CaRdiac cOne BEAm computed Tomography (ACROBEAT) to personalize image acquisition by adapting the gantry velocity and projection rate in real-time to changes in the patient's electrocardiogram (ECG) trace. METHODS: We compared the total number of projections acquired, estimated carotid artery widths and image quality between ACROBEAT and conventional (single rotation fixed gantry velocity and acquisition rate, no ECG-gating) scans in a simulation study and a proof-of-concept physical phantom experimental study. The simulation study dataset consisted of an XCAT digital software phantom programmed with five patient-measured ECG traces and artery motion curves. The ECG traces had average heart rates of 56, 64, 76, 86, and 100 bpm. To validate the concept experimentally, we designed and manufactured the physical phantom from an 8-mm diameter silicon rubber tubing cast into Phytagel. An artery motion curve and the ECG trace with an average heart rate of 56 bpm was passed through the phantom. To implement ACROBEAT on the Siemens ARTIS pheno angiography system for the proof-of-concept experimental study, the Siemens Test Automation Control System was used. The total number of projections acquired and estimated carotid artery widths were compared between the ACROBEAT and conventional scans. As the ground truth was available for the simulation studies, the image quality metrics of Root Mean Square Error (RMSE) and Structural Similarity Index (SSIM) were also utilized to assess image quality. RESULTS: In the simulation study, on average, ACROBEAT reduced the number of projections acquired by 63%, reduced carotid width estimation error by 65%, reduced RMSE by 11% and improved SSIM by 27% compared to conventional scans. In the proof-of-concept experimental study, ACROBEAT enabled a 60% reduction in the number of projections acquired and reduced carotid width estimation error by 69% compared to a conventional scan. CONCLUSION: A simulation and proof-of-concept experimental study was completed applying a novel dynamic imaging protocol, ACROBEAT, to imaging the carotid artery. The ACROBEAT results showed significantly improved image quality with fewer projections, offering potential applications to intracranial interventional procedures negatively affected by cardiac motion.


Assuntos
Tomografia Computadorizada de Feixe Cônico , Tomografia Computadorizada Quadridimensional , Artérias Carótidas/diagnóstico por imagem , Humanos , Processamento de Imagem Assistida por Computador , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador