Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 52
Filtrar
1.
Europace ; 26(7)2024 Jul 02.
Artigo em Inglês | MEDLINE | ID: mdl-38954426

RESUMO

AIMS: Prior case series showed promising results for cardioneuroablation in patients with vagally induced atrioventricular blocks (VAVBs). We aimed to examine the acute procedural characteristics and intermediate-term outcomes of electroanatomical-guided cardioneuroablation (EACNA) in patients with VAVB. METHODS AND RESULTS: This international multicentre retrospective registry included data collected from 20 centres. Patients presenting with symptomatic paroxysmal or persistent VAVB were included in the study. All patients underwent EACNA. Procedural success was defined by the acute reversal of atrioventricular blocks (AVBs) and complete abolition of atropine response. The primary outcome was occurrence of syncope and daytime second- or advanced-degree AVB on serial prolonged electrocardiogram monitoring during follow-up. A total of 130 patients underwent EACNA. Acute procedural success was achieved in 96.2% of the cases. During a median follow-up of 300 days (150, 496), the primary outcome occurred in 17/125 (14%) cases with acute procedural success (recurrence of AVB in 9 and new syncope in 8 cases). Operator experience and use of extracardiac vagal stimulation were similar for patients with and without primary outcomes. A history of atrial fibrillation, hypertension, and coronary artery disease was associated with a higher primary outcome occurrence. Only four patients with primary outcome required pacemaker placement during follow-up. CONCLUSION: This is the largest multicentre study demonstrating the feasibility of EACNA with encouraging intermediate-term outcomes in selected patients with VAVB. Studies investigating the effect on burden of daytime symptoms caused by the AVB are required to confirm these findings.


Assuntos
Bloqueio Atrioventricular , Sistema de Registros , Humanos , Masculino , Feminino , Estudos Retrospectivos , Idoso , Pessoa de Meia-Idade , Resultado do Tratamento , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/cirurgia , Ablação por Cateter/métodos , Fatores de Tempo , Estimulação do Nervo Vago/métodos , Técnicas Eletrofisiológicas Cardíacas , Síncope/etiologia , Recidiva , Nó Atrioventricular/cirurgia , Nó Atrioventricular/fisiopatologia
2.
Pacing Clin Electrophysiol ; 46(7): 717-720, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37335091

RESUMO

BACKGROUND: The use of left bundle branch pacing (LBBP) has dramatically increased since it was first described in 2016, but to date there are no published data on the safety of performing magnetic resonance imaging (MRI) in these patients. METHODS: Patients with LBBP who underwent MRI between January 2016 and October 2022 were retrospectively studied in our clinical center, which has a special program for imaging patients with cardiac devices. All patients underwent close cardiac monitoring throughout the MRI scans. Occurrence of arrhythmias or other adverse effects during MRI were assessed. LBBP lead parameters immediately pre- and post-MRI and at an outpatient follow-up were compared. RESULTS: Fifteen patients with LBBP underwent a total of 19 MRI sessions during the study period. Lead parameters did not significantly change after the MRI or on follow-up, which took place at a median of 91 days after the MRI. No patient developed arrhythmias during the MRI sessions, and no adverse effects such as lead dislodgement were reported. CONCLUSION: Although larger studies are necessary to verify our findings, MRI in patients with LBBP appears safe based on this initial case series.


Assuntos
Fascículo Atrioventricular , Bloqueio de Ramo , Humanos , Bloqueio de Ramo/diagnóstico por imagem , Bloqueio de Ramo/terapia , Bloqueio de Ramo/etiologia , Estimulação Cardíaca Artificial/métodos , Estudos Retrospectivos , Eletrocardiografia/métodos , Resultado do Tratamento
3.
Pacing Clin Electrophysiol ; 46(7): 583-591, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37221975

RESUMO

BACKGROUND: Bradyarrhythmias including sinus node dysfunction (SND) and atrioventricular block (AVB) can necessitate pacemaker (PPM) implantation in orthotopic heart transplant (OHT) recipients. Prior studies have shown conflicting findings regarding the effect of PPM implantation on survival. We evaluated the effect of PPM indication on long-term re-transplant-free survival in OHT patients. METHODS: We conducted a retrospective cohort study of OHT patients at UCLA Medical Center from 1985 to 2018. Indication for PPM (SND, AVB) was identified. Cox proportional hazards model with pacemaker implantation as a time-varying covariate was used to evaluate its effect on the primary endpoint of retransplant or death. We included 1609 OHTs in 1511 adult patients with median follow-up of 12 years. RESULTS: At transplant, patients were aged 53 ± 13 years and 1125 (74.5%) were male. Pacemakers were implanted in 109 (7.2%) patients; 65 for SND (4.3%) and 43 for AVB (2.8%). Repeat OHT was performed in 103 (6.4%) cases and 798 (52.8%) patients died during the follow-up period. The risk of the primary endpoint was significantly higher in patients requiring PPM for AVB (HR 3.0, 95% CI 2.1-4.2, p < .01) after controlling for age at OHT, gender, hypertension, diabetes, renal disease, history of repeat OHT, acute rejection, transplant coronary vasculopathy, and atrial fibrillation, but not PPM for SND (HR 1.0, 95% CI 0.70-1.4, p = 1.0). CONCLUSIONS: Patients who required PPM for AVB, but not SND, were at significantly higher risk of death or retransplant compared to patients who did not require PPM.


Assuntos
Fibrilação Atrial , Bloqueio Atrioventricular , Transplante de Coração , Marca-Passo Artificial , Adulto , Humanos , Masculino , Feminino , Estudos Retrospectivos , Fatores de Risco , Transplante de Coração/efeitos adversos , Bloqueio Atrioventricular/terapia , Bloqueio Atrioventricular/etiologia , Fibrilação Atrial/etiologia , Síndrome do Nó Sinusal/terapia
4.
Europace ; 22(11): 1680-1687, 2020 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-32830247

RESUMO

AIMS: Catheter ablation is an effective treatment for post-infarction ventricular tachycardia (VT). However, some patients may experience a worsened arrhythmia phenotype after ablation. We aimed to determine the prevalence and prognostic impact of arrhythmia exacerbation (AE) after post-infarction VT ablation. METHODS AND RESULTS: A total of 1187 consecutive patients (93% men, median age 68 years, median ejection fraction 30%) who underwent post-infarction VT ablation at six centres were included. Arrhythmia exacerbation was defined as post-ablation VT storm or incessant VT in patients without prior similar events. During follow-up (median 717 days), 426 (36%) patients experienced VT recurrence. Events qualifying as AE occurred in 67 patients (6%). Median times to VT recurrence with and without AE were 238 [interquartile range (IQR) 35-640] days and 135 (IQR 22-521) days, respectively (P = 0.25). Almost half of the patients (46%) who experienced AE experienced it within 6 months of the index procedure. Patients with AE had had longer ablation times during the ablation procedures compared to the rest of the patients (median 42 vs. 34 min, P = 0.02). Among patients with VT recurrence, the risk of death or heart transplantation was significantly higher in patients with than without AE (hazard ratio 1.99, 95% CI 1.28-3.10; P = 0.002) after adjusting for age, gender, ejection fraction, cardiac resynchronization therapy, post-ablation non-inducibility, and post-ablation amiodarone use. CONCLUSION: Arrhythmia exacerbation after ablation of infarct-related VT is infrequent but is independently associated with an adverse long-term outcome among patients who experience a VT recurrence. The mechanisms and mitigation strategies of AE after catheter ablation require further investigation.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Humanos , Infarto , Masculino , Prevalência , Prognóstico , Recidiva , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/epidemiologia , Taquicardia Ventricular/etiologia , Resultado do Tratamento
5.
PLoS Pathog ; 9(10): e1003658, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-24130482

RESUMO

The role of Type I interferon (IFN) during pathogenic HIV and SIV infections remains unclear, with conflicting observations suggesting protective versus immunopathological effects. We therefore examined the effect of IFNα/ß on T cell death and viremia in HIV infection. Ex vivo analysis of eight pro- and anti-apoptotic molecules in chronic HIV-1 infection revealed that pro-apoptotic Bak was increased in CD4+ T cells and correlated directly with sensitivity to CD95/Fas-mediated apoptosis and inversely with CD4+ T cell counts. Apoptosis sensitivity and Bak expression were primarily increased in effector memory T cells. Knockdown of Bak by RNA interference inhibited CD95/Fas-induced death of T cells from HIV-1-infected individuals. In HIV-1-infected patients, IFNα-stimulated gene expression correlated positively with ex vivo T cell Bak levels, CD95/Fas-mediated apoptosis and viremia and negatively with CD4+ T cell counts. In vitro IFNα/ß stimulation enhanced Bak expression, CD95/Fas expression and CD95/Fas-mediated apoptosis in healthy donor T cells and induced death of HIV-specific CD8+ T cells from HIV-1-infected patients. HIV-1 in vitro sensitized T cells to CD95/Fas-induced apoptosis and this was Toll-like receptor (TLR)7/9- and Type I IFN-dependent. This sensitization by HIV-1 was due to an indirect effect on T cells, as it occurred in peripheral blood mononuclear cell cultures but not purified CD4+ T cells. Finally, peak IFNα levels and viral loads correlated negatively during acute SIV infection suggesting a potential antiviral effect, but positively during chronic SIV infection indicating that either the virus drives IFNα production or IFNα may facilitate loss of viral control. The above findings indicate stage-specific opposing effects of Type I IFNs during HIV-1 infection and suggest a novel mechanism by which these cytokines contribute to T cell depletion, dysregulation of cellular immunity and disease progression.


Assuntos
Apoptose/imunologia , Linfócitos T CD4-Positivos/imunologia , Linfócitos T CD8-Positivos/imunologia , Infecções por HIV/imunologia , HIV-1/imunologia , Interferon-alfa/imunologia , Interferon beta/imunologia , Regulação para Cima/imunologia , Proteína Killer-Antagonista Homóloga a bcl-2/imunologia , Adolescente , Adulto , Animais , Linfócitos T CD4-Positivos/metabolismo , Linfócitos T CD4-Positivos/patologia , Linfócitos T CD8-Positivos/metabolismo , Linfócitos T CD8-Positivos/patologia , Criança , Pré-Escolar , Feminino , Infecções por HIV/metabolismo , Infecções por HIV/patologia , HIV-1/metabolismo , Humanos , Imunidade Celular , Lactente , Interferon-alfa/metabolismo , Interferon beta/metabolismo , Macaca mulatta , Masculino , Receptor 7 Toll-Like/imunologia , Receptor 7 Toll-Like/metabolismo , Receptor Toll-Like 9/imunologia , Receptor Toll-Like 9/metabolismo , Carga Viral/imunologia , Viremia/imunologia , Viremia/metabolismo , Proteína Killer-Antagonista Homóloga a bcl-2/biossíntese , Receptor fas/imunologia , Receptor fas/metabolismo
6.
J Biomed Inform ; 53: 81-92, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25240252

RESUMO

Patient monitors in modern hospitals have become ubiquitous but they generate an excessive number of false alarms causing alarm fatigue. Our previous work showed that combinations of frequently co-occurring monitor alarms, called SuperAlarm patterns, were capable of predicting in-hospital code blue events at a lower alarm frequency. In the present study, we extend the conceptual domain of a SuperAlarm to incorporate laboratory test results along with monitor alarms so as to build an integrated data set to mine SuperAlarm patterns. We propose two approaches to integrate monitor alarms with laboratory test results and use a maximal frequent itemsets mining algorithm to find SuperAlarm patterns. Under an acceptable false positive rate FPRmax, optimal parameters including the minimum support threshold and the length of time window for the algorithm to find the combinations of monitor alarms and laboratory test results are determined based on a 10-fold cross-validation set. SuperAlarm candidates are generated under these optimal parameters. The final SuperAlarm patterns are obtained by further removing the candidates with false positive rate>FPRmax. The performance of SuperAlarm patterns are assessed using an independent test data set. First, we calculate the sensitivity with respect to prediction window and the sensitivity with respect to lead time. Second, we calculate the false SuperAlarm ratio (ratio of the hourly number of SuperAlarm triggers for control patients to that of the monitor alarms, or that of regular monitor alarms plus laboratory test results if the SuperAlarm patterns contain laboratory test results) and the work-up to detection ratio, WDR (ratio of the number of patients triggering any SuperAlarm patterns to that of code blue patients triggering any SuperAlarm patterns). The experiment results demonstrate that when varying FPRmax between 0.02 and 0.15, the SuperAlarm patterns composed of monitor alarms along with the last two laboratory test results are triggered at least once for [56.7-93.3%] of code blue patients within an 1-h prediction window before code blue events and for [43.3-90.0%] of code blue patients at least 1-h ahead of code blue events. However, the hourly number of these SuperAlarm patterns occurring in control patients is only [2.0-14.8%] of that of regular monitor alarms with WDR varying between 2.1 and 6.5 in a 12-h window. For a given FPRmax threshold, the SuperAlarm set generated from the integrated data set has higher sensitivity and lower WDR than the SuperAlarm set generated from the regular monitor alarm data set. In addition, the McNemar's test also shows that the performance of the SuperAlarm set from the integrated data set is significantly different from that of the SuperAlarm set from the regular monitor alarm data set. We therefore conclude that the SuperAlarm patterns generated from the integrated data set are better at predicting code blue events.


Assuntos
Alarmes Clínicos , Coleta de Dados , Processamento Eletrônico de Dados , Adulto , Idoso , Algoritmos , California , Simulação por Computador , Sistemas Computacionais , Cuidados Críticos/métodos , Mineração de Dados , Reações Falso-Positivas , Feminino , Parada Cardíaca/diagnóstico , Humanos , Masculino , Pessoa de Meia-Idade , Sistemas On-Line , Distribuição de Poisson , Curva ROC , Insuficiência Respiratória/diagnóstico
7.
J Electrocardiol ; 48(6): 1062-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26362882

RESUMO

BACKGROUND: About 200,000 patients suffer from in-hospital cardiac arrest (IHCA) annually. Identification of at-risk patients is key to improving outcomes. The use of continuous ECG monitoring in identifying patients at risk for developing IHCA has not been studied. OBJECTIVE: To describe the profile and timing of ECG changes prior to IHCA. DESIGN: Retrospective, observational. SETTING: Single 520-bed tertiary care hospital. PATIENTS: IHCA in adults between April 2010 and March 2012 with at least 3 hours of continuous telemetry data immediately prior to IHCA. MEASUREMENTS: We evaluated up to 24 hours of telemetry data preceding IHCA for changes in PR, QRS, ST segment, arrhythmias, and QTc in ventricular tachycardia cases. We determined mechanism and likely clinical cause of the arrest by chart and telemetry review. RESULTS: We studied 81 IHCA patients, in whom the mechanism was ventricular tachycardia/fibrillation in 14 (18%), bradyasystolic in 21 (26%), and pulseless electrical activity (PEA) in 46 (56%). Preceding ECG changes were ST segment changes (31% of cases), atrial tachyarrhythmias (21%), bradyarrhythmias (28%), P wave axis change (21%),QRS prolongation (19%), PR prolongation (17%), isorhythmic dissociation (14%), nonsustained ventricular tachycardia (6%), and PR shortening (5%). At least one of these was present in 77% of all cases, and in 89% of IHCA caused by respiratory or multiorgan failure. Bradyarrhythmias were primarily seen with IHCA in the setting of respiratory or multiorgan failure, and PR and QRS prolongation with IHCA and concomitant multiorgan failure. LIMITATIONS: This is a retrospective study with a limited number of cases; each patient serves as their own control, and a separate control population has not yet been studied. CONCLUSIONS: ECG changes are commonly seen preceding IHCA, and have a pathophysiologic basis. Automated detection methods for ECG changes could potentially be used to better identify patients at risk for IHCA.


Assuntos
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/mortalidade , Eletrocardiografia/estatística & dados numéricos , Parada Cardíaca/mortalidade , Hospitalização/estatística & dados numéricos , Telemetria/estatística & dados numéricos , Adulto , Idoso , Idoso de 80 Anos ou mais , California , Causalidade , Comorbidade , Diagnóstico Precoce , Feminino , Parada Cardíaca/diagnóstico , Parada Cardíaca/prevenção & controle , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Reprodutibilidade dos Testes , Fatores de Risco , Sensibilidade e Especificidade , Taxa de Sobrevida , Telemedicina
8.
IEEE J Biomed Health Inform ; 28(5): 2650-2661, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38300786

RESUMO

Atrial fibrillation (AF) is a common cardiac arrhythmia with serious health consequences if not detected and treated early. Detecting AF using wearable devices with photoplethysmography (PPG) sensors and deep neural networks has demonstrated some success using proprietary algorithms in commercial solutions. However, to improve continuous AF detection in ambulatory settings towards a population-wide screening use case, we face several challenges, one of which is the lack of large-scale labeled training data. To address this challenge, we propose to leverage AF alarms from bedside patient monitors to label concurrent PPG signals, resulting in the largest PPG-AF dataset so far (8.5 M 30-second records from 24,100 patients) and demonstrating a practical approach to build large labeled PPG datasets. Furthermore, we recognize that the AF labels thus obtained contain errors because of false AF alarms generated from imperfect built-in algorithms from bedside monitors. Dealing with label noise with unknown distribution characteristics in this case requires advanced algorithms. We, therefore, introduce and open-source a novel loss design, the cluster membership consistency (CMC) loss, to mitigate label errors. By comparing CMC with state-of-the-art methods selected from a noisy label competition, we demonstrate its superiority in handling label noise in PPG data, resilience to poor-quality signals, and computational efficiency.


Assuntos
Algoritmos , Fibrilação Atrial , Fotopletismografia , Processamento de Sinais Assistido por Computador , Humanos , Fotopletismografia/métodos , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Alarmes Clínicos , Aprendizado de Máquina , Dispositivos Eletrônicos Vestíveis
9.
Artigo em Inglês | MEDLINE | ID: mdl-38499825

RESUMO

BACKGROUND: Cardioneuroablation has been emerging as a potential treatment alternative in appropriately selected patients with cardioinhibitory vasovagal syncope (VVS) and functional AV block (AVB). However the majority of available evidence has been derived from retrospective cohort studies performed by experienced operators. METHODS: The Cardioneuroablation for the Management of Patients with Recurrent Vasovagal Syncope and Symptomatic Bradyarrhythmias (CNA-FWRD) Registry is a multicenter prospective registry with cross-over design evaluating acute and long-term outcomes of VVS and AVB patients treated by conservative therapy and CNA. RESULTS: The study is a prospective observational registry with cross-over design for analysis of outcomes between a control group (i.e., behavioral and medical therapy only) and intervention group (Cardioneuroablation). Primary and secondary outcomes will only be assessed after enrollment in the registry. The follow-up period will be 3 years after enrollment. CONCLUSIONS: There remains a lack of prospective multicentered data for long-term outcomes comparing conservative therapy to radiofrequency CNA procedures particularly for key outcomes including recurrence of syncope, AV block, durable impact of disruption of the autonomic nervous system, and long-term complications after CNA. The CNA-FWRD registry has the potential to help fill this information gap.

10.
JACC Case Rep ; 8: 101728, 2023 Feb 15.
Artigo em Inglês | MEDLINE | ID: mdl-36860567

RESUMO

We describe the case of a 92-year-old male patient presenting with shortness of breath and an electrocardiogram showing bradycardia with irregular rhythm and varying QRS morphology. A differential diagnosis is discussed. (Level of Difficulty: Advanced.).

11.
JACC Case Rep ; 16: 101888, 2023 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-37396330

RESUMO

We show the virtual simulation of the fluoroscopic location of the membranous septum using preprocedural cardiac computed tomographic data sets. Recognizing the risk distance before the procedure can help individualize implantation strategy to reduce the risk of atrioventricular conduction axis damage during transcatheter aortic valve replacement. (Level of Difficulty: Advanced.).

12.
J Interv Card Electrophysiol ; 66(5): 1253-1263, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-36510109

RESUMO

BACKGROUND: Positron emission tomography computed tomography (PET-CT) is not routinely used for premature ventricular complexes (PVCs). Whether specific clinical factors are associated with abnormal PET-CT results is not clear. METHODS: The treatment courses and baseline characteristics of consecutive patients in a single center between 2012 and 2021, age > 18 years old, and who received 18F-fluorodeoxyglucose (FDG) PET-CT imaging for evaluation of PVCs were retrospectively analyzed. RESULTS: A total of 102 patients was included. Of these, 27 patients (26.4%) had abnormal PET-CT and 61 (59.8%) had normal imaging. Abnormal PET-CT findings were associated with non-sustained ventricular tachycardia (NSVT) (95.2% vs. 52.6%, p = 0.001), higher number of PVC morphologies (2.29 ± 0.7 vs. 1.31 ± 0.6, p < 0.001), greater PVC coupling interval dispersion (72.47 ± 66.4 ms vs. 13.42 ± 17.9 ms, p < 0.001), and greater likelihood of fast heart rate dependent PVCs (78.5% vs. 38.2%, p = 0.017). Fourteen (51.8%) patients had an abnormal PET-CT and abnormal late gadolinium enhancement (LGE). Patients with abnormal PET-CT were more frequently treated with immunosuppression (81.4% vs. 3.2%, p < .0001) than with catheter ablation (11.1% vs. 45.9%, p = 0.002) compared to the normal PET-CT group. Over a median follow-up of 862 days (IQR 134, 1407), PVC burden decreased in both groups [from 23 ± 16% to 9 ± 10% (p < 0.001) in abnormal PET-CT group and from 21 ± 15% to 7 ± 10% (p < 0.001) in normal PET-CT group]. CONCLUSIONS: Abnormal PET-CT findings were more commonly associated with NSVT, multiform PVCs, greater PVC coupling interval dispersion, and fast heart rate dependent PVCs. LGE was not sensitive for detecting inflammation. Immunosuppression was effective in managing PVCs with abnormal PET-CT.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Adulto , Pessoa de Meia-Idade , Complexos Ventriculares Prematuros/diagnóstico por imagem , Complexos Ventriculares Prematuros/cirurgia , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Meios de Contraste , Volume Sistólico/fisiologia , Gadolínio , Tomografia por Emissão de Pósitrons , Inflamação , Ablação por Cateter/métodos
13.
JACC Cardiovasc Imaging ; 16(10): 1348-1352, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37656118

RESUMO

Right ventricular perforation is a catastrophic complication of catheter-based intracardiac interventions. In this context, appreciation of 5 attachments of the right ventricle to the aortoventricular unit is essential to recognize extent of right ventricular free wall. We herein present progressive dissection and virtual and photographic endoscopic images of the hearts without distortion. Real dissection images show us how and where to avoid this complication by indicating the true muscular component of the ventricular septum. Both virtual and photographic endoscopic images, when combined with transillumination, beautifully shows the thin wall regions and trabeculations with unprecedented clarity. We believe recognition of these anatomical nuances can reduce the likelihood of right ventricular perforation.


Assuntos
Traumatismos Cardíacos , Septo Interventricular , Humanos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Valor Preditivo dos Testes , Diagnóstico por Imagem
14.
Heart Rhythm ; 20(12): 1708-1717, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37659454

RESUMO

BACKGROUND: Recurrent ventricular tachycardia (VT) after prior endocardial catheter ablation(s) presents challenges in the setting of prior cardiac surgery where percutaneous epicardial access may not be feasible. OBJECTIVE: The purpose of this study was to compare the outcomes of cryothermal vs radiofrequency ablation in direct surgical epicardial access procedures. METHODS: We performed a retrospective study of consecutive surgical epicardial VT ablation cases. Surgical cases using cryothermal vs radiofrequency ablation were analyzed and outcomes were compared. RESULTS: Between 2009 and 2022, 43 patients underwent either a cryothermal (n = 17) or a radiofrequency (n = 26) hybrid epicardial ablation procedure with direct surgical access. Both groups were similarly matched for age, sex, etiology of VT, and comorbidities with a high burden of refractory VT despite previous endocardial and/or percutaneous epicardial ablation procedures. The surgical access site was lateral thoracotomy (76.5%) in the cryothermal ablation group compared with lateral thoracotomy (42.3%) and subxiphoid approach (38.5%) in the radiofrequency group, with the remainder in both groups performed via median sternotomy. The ablation time was significantly shorter in those undergoing cryothermal ablation vs radiofrequency ablation (11.54 ± 15.5 minutes vs 48.48 ± 23.6 minutes; P < .001). There were no complications in the cryothermal ablation group compared with 6 patients with complications in the radiofrequency group. Recurrent VT episodes and all-cause mortality were similar in both groups. CONCLUSION: Hybrid surgical VT ablation with cryothermal or radiofrequency energy demonstrated similar efficacy outcomes. Cryothermal ablation was more efficient and safer than radiofrequency in a surgical setting and should be considered when surgical access is required.


Assuntos
Ablação por Cateter , Taquicardia Ventricular , Humanos , Estudos Retrospectivos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Endocárdio , Pericárdio/cirurgia , Resultado do Tratamento
15.
JACC Clin Electrophysiol ; 9(7 Pt 1): 936-948, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37438043

RESUMO

BACKGROUND: The clinical relevance and prognostic implications of ventricular parasystole are unknown. OBJECTIVES: This study sought to assess the prevalence of ventricular parasystole in patients with implantable cardioverter-defibrillators (ICDs) and ventricular parasystole's association with ventricular arrhythmias and conduction system abnormalities. METHODS: This study retrospectively evaluated patients who underwent ICD interrogation at a single center between June 1, 2019, and August 31, 2020, and reviewed all available ICD and electrocardiogram data. This study identified patients with ventricular parasystole and compared the prevalence of ventricular fibrillation (VF), ventricular tachycardia (VT), and new conduction system abnormalities in those with ≥5 years of intrinsic QRS-complex electrocardiograms to those without parasystole. RESULTS: This study included 374 patients (age 57 ± 21 years, 72% male, 45% nonischemic, 32% ischemic cardiomyopathy), of which, 104 (28%) had VT only, 39 (10%) VF only, and 10 (3%) both VT/VF. Ventricular parasystole was identified in 33 patients (9%); parasystolic foci were predominantly from the His-Purkinje system. Compared with those without parasystole, patients with parasystole had a significantly higher rate of VF (36% vs 11%; P < 0.01), but not VT (42% vs 29%; P = 0.12). Patients with parasystole, compared with those without parasystole, had a higher prevalence of new conduction abnormalities, particularly progressive intraventricular conduction delay (11 of 18 [61%] vs 12 of 83 [14%]; P < 0.01) and new right bundle branch block (4 of 18 [22%] vs 1 of 83 [1%]; P < 0.01). CONCLUSIONS: Ventricular parasystole was strongly associated with new conduction system abnormalities and VF in patients who have cardiomyopathy with ICDs, suggesting a potential link between VF and His-Purkinje damage in this patient population.


Assuntos
Cardiomiopatias , Parassístole , Taquicardia Ventricular , Humanos , Masculino , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Fibrilação Ventricular/epidemiologia , Fibrilação Ventricular/etiologia , Estudos Retrospectivos , Arritmias Cardíacas , Taquicardia Ventricular/epidemiologia , Cardiomiopatias/complicações , Cardiomiopatias/epidemiologia , Bloqueio de Ramo
16.
J Biomed Inform ; 45(5): 913-21, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22465785

RESUMO

Bedside monitors are ubiquitous in acute care units of modern healthcare enterprises. However, they have been criticized for generating an excessive number of false positive alarms causing alarm fatigue among care givers and potentially compromising patient safety. We hypothesize that combinations of regular monitor alarms denoted as SuperAlarm set may be more indicative of ongoing patient deteriorations and hence predictive of in-hospital code blue events. The present work develops and assesses an alarm mining approach based on finding frequent combinations of single alarms that are also specific to code blue events to compose a SuperAlarm set. We use 4-way analysis of variance (ANOVA) to investigate the influence of four algorithm parameters on the performance of the data mining approach. The results are obtained from millions of monitor alarms from a cohort of 223 adult code blue and 1768 control patients using a multiple 10-fold cross-validation experiment setup. Using the optimal setting of parameters determined in the cross-validation experiment, final SuperAlarm sets are mined from the training data and used on an independent test data set to simulate running a SuperAlarm set against live regular monitor alarms. The ANOVA shows that the content of a SuperAlarm set is influenced by a subset of key algorithm parameters. Simulation of the extracted SuperAlarm set shows that it can predict code blue events one hour ahead with sensitivity between 66.7% and 90.9% while producing false SuperAlarms for control patients that account for between 2.2% and 11.2% of regular monitor alarms depending on user-supplied acceptable false positive rate. We conclude that even though the present work is still preliminary due to the usage of a moderately-sized database to test our hypothesis it represents an effort to develop algorithms to alleviate the alarm fatigue issue in a unique way.


Assuntos
Reanimação Cardiopulmonar , Alarmes Clínicos , Mineração de Dados/métodos , Modelos Estatísticos , Monitorização Fisiológica/métodos , Adulto , Idoso , Algoritmos , Análise de Variância , Estudos de Casos e Controles , Humanos , Pessoa de Meia-Idade , Reprodutibilidade dos Testes
17.
Resuscitation ; 179: 1-8, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35905864

RESUMO

INTRODUCTION: Respiratory failure is a common cause of pulseless electrical activity (PEA) and asystolic cardiac arrest, but the changes in heart rate (HR) pre-arrest are not well described. We describe HR dynamics prior to in-hospital cardiac arrest (IHCA) among PEA/asystole arrest patients with respiratory etiology. METHODS: In this retrospective study, we evaluated 139 patients with 3-24 hours of continuous electrocardiogram data recorded preceding PEA/asystole IHCA from 2010-2017. We identified respiratory failure cases by chart review and evaluated electrocardiogram data to identify patterns of HR changes, sinus bradycardia or sinus arrest, escape rhythms, and development right ventricular strain prior to IHCA. RESULTS: A higher proportion of respiratory cases (58/73, 79 %) fit a model of HR response characterized by tachycardia followed by rapid HR decrease prior to arrest, compared to non-respiratory cases (30/66, 45 %, p < 0.001). Among the 58 respiratory cases fitting this model, 36 (62 %) had abrupt increase in HR occurring 64 (IQR 23-191) minutes prior to arrest, while 22 (38 %) had stable tachycardia until time of HR decrease. Mean peak HR was 123 ± 21 bpm. HR decrease occurred 3.0 (IQR 2.0-7.0) minutes prior to arrest. Sinus arrest occurred during the bradycardic phase in 42/58 of cases; escape rhythms were present in all but 2/42 (5 %) cases. Right ventricular strain ECG pattern, when present, occurred at a median of 2.2 (IQR -0.05-17) minutes prior to onset of HR decrease. CONCLUSION: IHCAs of respiratory etiology follow a model of HR increase from physiologic compensation to hypoxia, followed by rapid HR decrease prior to arrest.


Assuntos
Reanimação Cardiopulmonar , Parada Cardíaca , Insuficiência Respiratória , Parada Cardíaca/complicações , Parada Cardíaca/terapia , Frequência Cardíaca/fisiologia , Hospitais , Humanos , Estudos Retrospectivos
18.
JACC Case Rep ; 4(24): 101645, 2022 Dec 21.
Artigo em Inglês | MEDLINE | ID: mdl-36684037

RESUMO

Infection of leadless pacemakers (LPM) is rare, even in patients at high risk for infections. Only 3 cases of LPM infection have been documented in the literature, all occurring within 1 month of device implantation. We report the first case, to our knowledge, of late-onset LPM infection, developing almost 2 years after implantation. (Level of Difficulty: Beginner.).

19.
J Forensic Sci ; 67(5): 1924-1931, 2022 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-35883263

RESUMO

Cardiac implantable electronic devices (CIEDs) store information continuously; however, the log of these devices is rarely analyzed in forensic practice. We retrospectively reviewed all cases referred for CIED interrogation by the Los Angeles County Department of Medical Examiner-Coroner between 2001 and 2020. According to the Department's practice, CIED interrogation may be requested for decedents in which details or cause of death are not clear from autopsy and clinical history. The CIED analysis was considered informative for the coroner's investigation either if it detected an arrhythmia or malfunction likely related to decedent's terminal event or if it was essential to determine time of death or identity of decedent. A total of 57 CIEDs were evaluated during the 20-year period. In almost half of cases (26/57: 45.6%), device analysis was informative for coroner's investigation. Arrhythmias likely related to terminal event were commonly detected (21/57: 36.8%). Device malfunction was identified as the likely cause of death in almost 10% of decedents (5/57: 8.8%), including three cases of battery depletion (3/57: 5.3%), one case of misclassification of ventricular tachycardia as supraventricular tachycardia with failure to deliver therapy (1/57: 1.7%), and one case of lead failure due to a broken pacing wire (1/57: 1.7%). Not infrequently, CIED interrogation was essential for determination of time of death (9/57: 15.8%), and there was one case (1/57: 1.7%) in which interrogation was essential for identifying the decedent. Our study shows that postmortem CIED interrogation can provide unique information regarding mechanism and time of death, and decedent's identity.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Arritmias Cardíacas , Médicos Legistas , Humanos , Los Angeles , Estudos Retrospectivos
20.
Heart Rhythm ; 19(12): 2064-2072, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35932988

RESUMO

BACKGROUND: The use of cardiac positron emission tomography-computed tomography (PET-CT) is increasingly used for the detection of underlying inflammation in patients with ventricular arrhythmias (ventricular tachycardia/ventricular fibrillation [VT/VF]), but the role of PET-CT remains undefined, particularly for patients who do not meet Task Force criteria for sarcoidosis. OBJECTIVE: The purpose of this study was to determine the utility of PET-CT for clinical evaluation of VT/VF in patients with nonischemic cardiomyopathy. METHODS: Consecutive patients with nonischemic cardiomyopathy and VT/VF who underwent cardiac PET-CT to detect inflammation between 2012 and 2019 were analyzed for baseline demographic characteristics, imaging results, and outcomes. Patients with known sarcoidosis or other conditions requiring immunosuppressive therapy were excluded. RESULTS: PET-CT was performed in 133 patients with mean age 56.3 ± 13.5 years and left ventricular ejection fraction 43% ± 16.1%, with evidence of myocardial inflammation detected in 32 (23.5%). Patients with myocardial inflammation were managed conservatively with medical therapy including immunosuppressive agents. Ten patients with myocardial inflammation ultimately required catheter ablation for ongoing arrhythmias. There was no significant difference in arrhythmia recurrence between PET-positive and PET-negative groups (37.5% vs 32.4%; P = .43) or in time to recurrence (P = .26), in spite of the disparate management strategies. Gadolinium-enhanced cardiac magnetic resonance imaging was performed in 96 patients (72%); however, magnetic resonance imaging did not detect 31% of cases with active inflammation that were otherwise detected on PET-CT. CONCLUSION: The use of PET-CT significantly improves the detection of underlying myocardial inflammation contributing to ventricular arrhythmias. Management of these patients with immunosuppressive medical therapy is effective for arrhythmia control and may obviate the need for invasive ablation procedures in some patients.


Assuntos
Cardiomiopatias , Miocardite , Sarcoidose , Taquicardia Ventricular , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Volume Sistólico , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Função Ventricular Esquerda , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia , Tomografia por Emissão de Pósitrons , Cardiomiopatias/diagnóstico , Cardiomiopatias/diagnóstico por imagem , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/terapia , Sarcoidose/complicações , Sarcoidose/diagnóstico , Sarcoidose/terapia , Fibrilação Ventricular , Miocardite/diagnóstico , Miocardite/diagnóstico por imagem , Inflamação/complicações , Inflamação/diagnóstico
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA