Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
BMC Musculoskelet Disord ; 22(1): 230, 2021 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-33639901

RESUMO

BACKGROUND: Total hip arthroplasty (THA) is an effective procedure for patients with end-stage hip osteoarthritis. However, whether or not pre-operatively existing functional deficits are persisting several years post-surgery in the affected limb has not been thoroughly researched. Therefore, the primary aim of this preliminary study was to include patients four to five years after undergoing THA and to investigate potential differences between the operated and non-operated leg in hip strength, range of motion (ROM), balance, and gait. The secondary aim was to compare these values from the operated leg of the patients to those of the legs of healthy subjects. METHODS: Sixteen patients (age: 65.20 ± 5.32 years) following unilateral THA (post-operation time: 4.7 ± 0.7 years) and ten, healthy, age-matched control subjects (age: 60.85 ± 7.57 years) were examined for maximum isometric hip muscle strength, active ROM of the hip joint, balance and gait on both limbs. Paired t-tests were used to assess the inter-limb differences in the THA group. Analyses of covariance (ANCOVA) were performed to compare groups, using age as a covariate. RESULTS: The analysis of inter-limb differences in patients following THA revealed significant deficits on the operated side for hip abduction strength (p = 0.02), for hip flexion ROM (p < 0.01) and for balance in terms of the length of center of pressure (COP) (p = 0.04). Compared to values of the control subjects, the patients demonstrated significantly reduced hip strength in flexion, extension and abduction (p < 0.05) on the operated leg as well as reduced ROM measures in hip flexion, extension and abduction (p < 0.05). CONCLUSIONS: The first results of this explorative study indicated that inter-limb differences as well as reduced hip strength and hip ROM compared with control subjects were still present four to five years after THA. These persisting asymmetries and deficits in patients following THA may be one explanation for the decrease in health-related quality of life (HRQoL) seen in patients over the years after surgery. Further studies are required to replicate these findings with a larger sample size. TRIAL REGISTRATION: DRKS, DRKS00016945. Registered 12 March 2019 - Retrospectively registered.


Assuntos
Artroplastia de Quadril , Osteoartrite do Quadril , Idoso , Artroplastia de Quadril/efeitos adversos , Estudos Transversais , Articulação do Quadril/cirurgia , Humanos , Pessoa de Meia-Idade , Osteoartrite do Quadril/cirurgia , Qualidade de Vida , Amplitude de Movimento Articular
2.
Proc Inst Mech Eng H ; 226(2): 170-5, 2012 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22468468

RESUMO

In the biomechanical literature only a few studies are available focusing on the determination of joint loading within the lower extremities in snowboarding. These studies are limited to analysis in a restricted capture volume due to the use of optical video-based systems. To overcome this restriction the aim of the present study was to develop a method to determine net joint moments within the lower extremities in snowboarding for complete measurement runs. An experienced snowboarder performed several runs equipped with two custom-made force plates as well as a full-body inertial measurement system. A rigid, multi-segment model was developed to describe the motion and loads within the lower extremities. This model is based on an existing lower-body model and designed to be run by the OpenSim software package. Measured kinetic and kinematic data were imported into the OpenSim program and inverse dynamic calculations were performed. The results illustrate the potential of the developed method for the determination of joint loadings within the lower extremities for complete measurement runs in a real snowboarding environment. The calculated net joint moments of force are reasonable in comparison to the data presented in the literature. A good reliability of the method seems to be indicated by the low data variation between different turns. Due to the unknown accuracy of this method the application for inter-individual studies as well as studies of injury mechanisms may be limited. For intra-individual studies comparing different snowboarding techniques as well as different snowboard equipment the method seems to be beneficial. The validity of the method needs to be studied further.


Assuntos
Aceleração , Articulações/fisiologia , Perna (Membro)/fisiologia , Monitorização Ambulatorial/instrumentação , Esqui/fisiologia , Suporte de Carga/fisiologia , Adulto , Desenho de Equipamento , Equipamentos e Provisões , Humanos , Masculino , Equipamentos Esportivos , Estresse Mecânico , Torque
3.
Biomed Tech (Berl) ; 62(6): 615-622, 2017 Nov 27.
Artigo em Inglês | MEDLINE | ID: mdl-28099115

RESUMO

Gait analysis is an important and useful part of the daily therapeutic routine. InvestiGAIT, an inertial sensor-based system, was developed for using in different research projects with a changing number and position of sensors and because commercial systems do not capture the motion of the upper body. The current study is designed to evaluate the reliability of InvestiGAIT consisting of four off-the-shelf inertial sensors and in-house capturing and analysis software. Besides the determination of standard gait parameters, the motion of the upper body (pelvis and spine) can be investigated. Kinematic data of 25 healthy individuals (age: 25.6±3.3 years) were collected using a test-retest design with 1 week between measurement sessions. We calculated different parameters for absolute [e.g. limits of agreement (LoA)] and relative reliability [intraclass correlation coefficients (ICC)]. Our results show excellent ICC values for most of the gait parameters. Midswing height (MH), height difference (HD) of initial contact (IC) and terminal contact (TC) and stride length (SL) are the gait parameters, which did not exhibit acceptable values representing absolute reliability. Moreover, the parameters derived from the motion of the upper body (pelvis and spine) show excellent ICC values or high correlations. Our results indicate that InvestiGAIT is suitable for reliable measurement of almost all the considered gait parameters.


Assuntos
Marcha , Fenômenos Biomecânicos , Humanos , Movimento (Física) , Reprodutibilidade dos Testes , Software
4.
J Appl Biomech ; 26(4): 516-21, 2010 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21245513

RESUMO

This study aims at determining the accuracy of a full body inertial measurement system in a real skiing environment in comparison with an optical video based system. Recent studies have shown the use of inertial measurement systems for the determination of kinematical parameters in alpine skiing. However, a quantitative validation of a full body inertial measurement system for the application in alpine skiing is so far not available. For the purpose of this study, a skier performed a test-run equipped with a full body inertial measurement system in combination with a DGPS. In addition, one turn of the test-run was analyzed by an optical video based system. With respect to the analyzed angles, a maximum mean difference of 4.9° was measured. No differences in the measured angles between the inertial measurement system and the combined usage with a DGPS were found. Concerning the determination of the skier's trajectory, an additional system (e.g., DGPS) must be used. As opposed to optical methods, the main advantages of the inertial measurement system are the determination of kinematical parameters without the limitation of restricted capture volume, and small time costs for the measurement preparation and data analysis.


Assuntos
Articulação do Joelho/fisiologia , Monitorização Ambulatorial/instrumentação , Processamento de Sinais Assistido por Computador , Esqui/fisiologia , Fenômenos Biomecânicos , Desenho de Equipamento , Sistemas de Informação Geográfica , Humanos , Imageamento Tridimensional , Gravação em Vídeo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA