Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
Eur J Clin Invest ; 54(4): e14139, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38063028

RESUMO

BACKGROUND: Technological progress in the acquisition of medical images and the extraction of underlying quantitative imaging data has introduced exciting prospects for the diagnostic assessment of a wide range of conditions. This study aims to investigate the diagnostic utility of a machine learning classifier based on dual-energy computed tomography (DECT) radiomics for classifying pulmonary embolism (PE) severity and assessing the risk for early death. METHODS: Patients who underwent CT pulmonary angiogram (CTPA) between January 2015 and March 2022 were considered for inclusion in this study. Based on DECT imaging, 107 radiomic features were extracted for each patient using standardized image processing. After dividing the dataset into training and test sets, stepwise feature reduction based on reproducibility, variable importance and correlation analyses were performed to select the most relevant features; these were used to train and validate the gradient-boosted tree models. RESULTS: The trained machine learning classifier achieved a classification accuracy of .90 for identifying high-risk PE patients with an area under the receiver operating characteristic curve of .59. This CT-based radiomics signature showed good diagnostic accuracy for risk stratification in individuals presenting with central PE, particularly within higher risk groups. CONCLUSION: Models utilizing DECT-derived radiomics features can accurately stratify patients with pulmonary embolism into established clinical risk scores. This approach holds the potential to enhance patient management and optimize patient flow by assisting in the clinical decision-making process. It also offers the advantage of saving time and resources by leveraging existing imaging to eliminate the necessity for manual clinical scoring.


Assuntos
Embolia Pulmonar , Tomografia Computadorizada por Raios X , Humanos , Tomografia Computadorizada por Raios X/métodos , Radiômica , Reprodutibilidade dos Testes , Embolia Pulmonar/diagnóstico por imagem , Medição de Risco , Estudos Retrospectivos
2.
Artigo em Inglês | MEDLINE | ID: mdl-38762707

RESUMO

An accurate diagnosis of venous thromboembolism (VTE) is crucial, given the potential for high mortality in undetected cases. Strategic D-dimer testing may aid in identifying low-risk patients, preventing overdiagnosis and reducing imaging costs. We conducted a retrospective, comparative analysis to assess the potential cost savings that could be achieved by adopting different approaches to determine the most effective D-dimer cut-off value in cancer patients with suspected VTE, compared to the commonly used rule-out cut-off level of 0.5 mg/L. The study included 526 patients (median age 65, IQR 55-75) with a confirmed cancer diagnosis who underwent D-dimer testing. Among these patients, the VTE prevalence was 29% (n = 152). Each diagnostic strategy's sensitivity, specificity, negative likelihood ratio (NLR), as well as positive likelihood ratio (PLR), and the proportion of patients exhibiting a negative D-dimer test result, were calculated. The diagnostic strategy that demonstrated the best balance between specificity, sensitivity, NLR, and PLR, utilized an inverse age-specific cut-off level for D-dimer [0.5 + (66-age) × 0.01 mg/L]. This method yielded a PLR of 2.9 at a very low NLR for the exclusion of VTE. We observed a significant cost reduction of 4.6% and 1.0% for PE and DVT, respectively. The utilization of an age-adjusted cut-off [patient's age × 0.01 mg/L] resulted in the highest cost savings, reaching 8.1% for PE and 3.4% for DVT. Using specified D-dimer cut-offs in the diagnosis of VTE could improve economics, considering the limited occurrence of confirmed cases among patients with suspected VTE.

3.
Langenbecks Arch Surg ; 409(1): 111, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38587539

RESUMO

PURPOSE: The presence of an aberrant right hepatic artery (aRHA), arising from the superior mesenteric artery, is a common variant of the liver vascular anatomy. Considering that tumor spread occurs along vessels, the question arises, whether the presence of an aRHA influences the oncologic outcome after resection for cancer of the pancreatic head. METHODS: Patients with ductal adenocarcinoma of the pancreatic head, who underwent resection from 2011 to 2020 at the Frankfurt University Hospital, Germany, were analyzed retrospectively. Surgical records and computed tomography imaging were reviewed for the presence of aRHA. Overall and disease-free survival as well as hepatic recurrence were analyzed according to the presence of aRHA. RESULTS: aRHA was detected in 21 out of 145 patients (14.5%). The median overall survival was 26 months (95%CI 20.8-34.4), median disease-free survival was 12.1 months (95%CI 8.1-17.3). There was no significant difference in overall survival (26.1 versus 21.4 months, adjusted hazard ratio 1.31, 95%CI 0.7-2.46, p = 0.401) or disease-free survival (14.5 months versus 12 months, adjusted hazard ratio 0.98, 95%CI 0.57-1.71, p = 0.957) without and with aRHA. The hepatic recurrence rate was 24.4.% with conventional anatomy versus 30.8% with aRHA (adjusted odds ratio 1.36, 95%CI 0.3-5.38, p = 0.669). In the multivariable analysis, only lymphatic vessel invasion was an independent prognostic factor for hepatic recurrence. CONCLUSIONS: The presence of an aRHA does not seem to influence the long-term survival and hepatic recurrence after resection for ductal adenocarcinoma of the pancreatic head.


Assuntos
Adenocarcinoma , Artéria Hepática , Humanos , Artéria Hepática/cirurgia , Estudos Retrospectivos , Pâncreas , Pancreatectomia
4.
Emerg Radiol ; 31(3): 303-311, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38523224

RESUMO

PURPOSE: Recent advancements in medical imaging have transformed diagnostic assessments, offering exciting possibilities for extracting biomarker-based information. This study aims to investigate the capabilities of a machine learning classifier that incorporates dual-energy computed tomography (DECT) radiomics. The primary focus is on discerning and predicting outcomes related to pulmonary embolism (PE). METHODS: The study included 131 participants who underwent pulmonary artery DECT angiography between January 2015 and March 2022. Among them, 104 patients received the final diagnosis of PE and 27 patients served as a control group. A total of 107 radiomic features were extracted for every case based on DECT imaging. The dataset was divided into training and test sets for model development and validation. Stepwise feature reduction identified the most relevant features, which were used to train a gradient-boosted tree model. Receiver operating characteristics analysis and Cox regression tests assessed the association of texture features with overall survival. RESULTS: The trained machine learning classifier achieved a classification accuracy of 0.94 for identifying patients with acute PE with an area under the receiver operating characteristic curve of 0.91. Radiomics features could be valuable for predicting outcomes in patients with PE, demonstrating strong prognostic capabilities in survival prediction (c-index, 0.991 [0.979-1.00], p = 0.0001) with a median follow-up of 130 days (IQR, 38-720). Notably, the inclusion of clinical or DECT parameters did not enhance predictive performance. CONCLUSION: In conclusion, our study underscores the promising potential of leveraging radiomics on DECT imaging for the identification of patients with acute PE and predicting their outcomes. This approach has the potential to improve clinical decision-making and patient management, offering efficiencies in time and resources by utilizing existing DECT imaging without the need for an additional scoring system.


Assuntos
Angiografia por Tomografia Computadorizada , Aprendizado de Máquina , Embolia Pulmonar , Humanos , Embolia Pulmonar/diagnóstico por imagem , Masculino , Feminino , Prognóstico , Pessoa de Meia-Idade , Angiografia por Tomografia Computadorizada/métodos , Idoso , Biomarcadores/sangue , Valor Preditivo dos Testes , Estudos Retrospectivos
5.
Radiology ; 308(2): e223150, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37552067

RESUMO

Background In patients with distal radius fractures (DRFs), low bone mineral density (BMD) is associated with bone substitute use during surgery and bone nonunion, but BMD information is not regularly available. Purpose To evaluate the feasibility of dual-energy CT (DECT)-based BMD assessment from routine examinations in the distal radius and the relationship between the obtained BMD values, the occurrence of DRFs, bone nonunion, and use of surgical bone substitute. Materials and Methods Scans in patients who underwent routine dual-source DECT in the distal radius between January 2016 and December 2021 were retrospectively acquired. Phantomless BMD assessment was performed using the delineated trabecular bone of a nonfractured segment of the distal radius and both DECT image series. CT images and health records were examined to determine fracture severity, surgical management, and the occurrence of bone nonunion. Associations of BMD with the occurrence of DRFs, bone nonunion, and bone substitute use at surgical treatment were examined with generalized additive models and receiver operating characteristic analysis. Results This study included 263 patients (median age, 52 years; IQR, 36-64 years; 132 female patients), of whom 192 were diagnosed with fractures. Mean volumetric BMD was lower in patients who sustained a DRF (93.9 mg/cm3 vs 135.4 mg/cm3; P < .001), required bone substitutes (79.6 mg/cm3 vs 95.5 mg/cm3; P < .001), and developed bone nonunion (71.1 mg/cm3 vs 96.5 mg/cm3; P < .001). Receiver operating characteristic curve analysis identified these patients with an area under the curve of 0.71-0.91 (P < .001). Lower BMD increased the risk to sustain DRFs, develop bone nonunion, and receive bone substitutes at surgery (P < .001). Conclusion DECT-based BMD assessment at routine examinations is feasible and could help predict surgical bone substitute use and the occurrence of bone nonunion in patients with DRFs. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Carrino in this issue.


Assuntos
Substitutos Ósseos , Fraturas Ósseas , Fraturas do Punho , Humanos , Feminino , Pessoa de Meia-Idade , Densidade Óssea , Rádio (Anatomia)/diagnóstico por imagem , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Absorciometria de Fóton
6.
NMR Biomed ; 36(2): e4828, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36082477

RESUMO

Whole-body magnetic resonance imaging (MRI) has become increasingly popular in oncology. However, the long acquisition time might hamper its widespread application. We sought to assess and compare free-breathing sequences with conventional breath-hold examinations in whole-body MRI using an automated workflow process. This prospective study consisted of 20 volunteers and six patients with a variety of pathologies who had undergone whole-body 1.5-T MRI that included T1-weighted radial and Dixon volumetric interpolated breath-hold examination sequences. Free-breathing sequences were operated by using an automated user interface. Image quality, diagnostic confidence, and image noise were evaluated by two experienced radiologists. Additionally, signal-to-noise ratio was measured. Diagnostic performance for the overall detection of pathologies was assessed using the area under the receiver operating characteristics curve (AUC). Study participants were asked to rate their examination experiences in a satisfaction survey. MR free-breathing scans were rated as at least equivalent to conventional MR scans in more than 92% of cases, showing high overall diagnostic accuracy (95% [95% CI 92-100]) and performance (AUC 0.971, 95% CI 0.942-0.988; p < 0.0001) for the assessment of pathologies at simultaneously reduced examination times (25 ± 2 vs. 32 ± 3 min; p < 0.0001). Interrater agreement was excellent for both free-breathing (Ï° = 0.96 [95% CI 0.88-1.00]) and conventional scans (Ï° = 0.93 [95% CI 0.84-1.00]). Qualitative and quantitative assessment for image quality, image noise, and diagnostic confidence did not differ between the two types of MR image acquisition (all p > 0.05). Scores for patient satisfaction were significantly better for free-breathing compared with breath-hold examinations (p = 0.0145), including significant correlations for the grade of noise (r = 0.79, p < 0.0001), tightness (r = 0.71, p < 0.0001), and physical fatigue (r = 0.52, p = 0.0065). In summary, free-breathing whole-body MRI in tandem with an automated user interface yielded similar diagnostic performance at equivalent image quality and shorter acquisition times compared to conventional breath-hold sequences.


Assuntos
Interpretação de Imagem Assistida por Computador , Imageamento por Ressonância Magnética , Humanos , Aumento da Imagem/métodos , Interpretação de Imagem Assistida por Computador/métodos , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Imagem Corporal Total , Fluxo de Trabalho
7.
Eur J Clin Invest ; 53(12): e14075, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-37571983

RESUMO

BACKGROUND: To investigate the potential of radiomic features and dual-source dual-energy CT (DECT) parameters in differentiating between benign and malignant mediastinal masses and predicting patient outcomes. METHODS: In this retrospective study, we analysed data from 90 patients (38 females, mean age 51 ± 25 years) with confirmed mediastinal masses who underwent contrast-enhanced DECT. Attenuation, radiomic features and DECT-derived imaging parameters were evaluated by two experienced readers. We performed analysis of variance (ANOVA) and Chi-square statistic tests for data comparison. Receiver operating characteristic curve analysis and Cox regression tests were used to differentiate between mediastinal masses. RESULTS: Of the 90 mediastinal masses, 49 (54%) were benign, including cases of thymic hyperplasia/thymic rebound (n = 10), mediastinitis (n = 16) and thymoma (n = 23). The remaining 41 (46%) lesions were classified as malignant, consisting of lymphoma (n = 28), mediastinal tumour (n = 4) and thymic carcinoma (n = 9). Significant differences were observed between benign and malignant mediastinal masses in all DECT-derived parameters (p ≤ .001) and 38 radiomic features (p ≤ .044) obtained from contrast-enhanced DECT. The combination of these methods achieved an area under the curve of .98 (95% CI, .893-1.000; p < .001) to differentiate between benign and malignant masses, with 100% sensitivity and 91% specificity. Throughout a follow-up of 1800 days, a multiparametric model incorporating radiomic features, DECT parameters and gender showed promising prognostic power in predicting all-cause mortality (c-index = .8 [95% CI, .702-.890], p < .001). CONCLUSIONS: A multiparametric approach combining radiomic features and DECT-derived imaging biomarkers allows for accurate and noninvasive differentiation between benign and malignant masses in the anterior mediastinum.


Assuntos
Linfoma , Neoplasias do Mediastino , Neoplasias do Timo , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Tomografia Computadorizada por Raios X/métodos , Estudos Retrospectivos , Neoplasias do Timo/diagnóstico por imagem , Neoplasias do Timo/patologia , Linfoma/diagnóstico por imagem , Neoplasias do Mediastino/diagnóstico por imagem
8.
Eur J Clin Invest ; 53(4): e13914, 2023 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-36444723

RESUMO

BACKGROUND: D-dimer testing is known to have a high sensitivity at simultaneously low specificity, resulting in nonspecific elevations in a variety of conditions. METHODS: This retrospective study sought to assess diagnostic and prognostic features of D-dimers in cancer patients referred to the emergency department for suspected pulmonary embolism (PE) and deep vein thrombosis (DVT). In total, 526 patients with a final adjudicated diagnosis of PE (n = 83) and DVT (n = 69) were enrolled, whereas 374 patients served as the comparative group, in which venous thromboembolism (VTE) has been excluded. RESULTS: For the identification of VTE, D-dimers yielded the highest positive predictive value of 96% (95% confidence interval (CI), 85-99) at concentrations of 9.9 mg/L and a negative predictive value of 100% at .6 mg/L (95% CI, 97-100). At the established rule-out cut-off level of .5 mg/L, D-dimers were found to be very sensitive (100%) at a moderate specificity of nearly 65%. Using an optimised cut-off value of 4.9 mg/L increased the specificity to 95% for the detection of life-threatening VTE at the cost of moderate sensitivities (64%). During a median follow-up of 30 months, D-dimers positively correlated with the reoccurrence of VTE (p = .0299) and mortality in both cancer patients with VTE (p < .0001) and without VTE (p = .0008). CONCLUSIONS: Although D-dimer testing in cancer patients is discouraged by current guidelines, very high concentrations above the 10-fold upper reference limit contain diagnostic and prognostic information and might be helpful in risk assessment, while low concentrations remain useful for ruling out VTE.


Assuntos
Neoplasias , Tromboembolia Venosa , Humanos , Tromboembolia Venosa/diagnóstico , Prognóstico , Estudos Retrospectivos , Produtos de Degradação da Fibrina e do Fibrinogênio , Valor Preditivo dos Testes
9.
Eur J Clin Invest ; 53(10): e14060, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37409393

RESUMO

BACKGROUND: Cancer is a well-known risk factor for venous thromboembolism (VTE). A combined strategy of D-dimer testing and clinical pre-test probability is usually used to exclude VTE. However, its effectiveness is diminished in cancer patients due to reduced specificity, ultimately leading to a decreased clinical utility. This review article seeks to provide a comprehensive summary of how to interpret D-dimer testing in cancer patients. METHODS: In accordance with PRISMA standards, literature pertaining to the diagnostic and prognostic significance of D-dimer testing in cancer patients was carefully chosen from reputable sources such as PubMed and the Cochrane databases. RESULTS: D-dimers have not only a diagnostic value in ruling out VTE but can also serve as an aid for rule-in if their values exceed 10-times the upper limit of normal. This threshold allows a diagnosis of VTE in cancer patients with a positive predictive value of more than 80%. Moreover, elevated D-dimers carry important prognostic information and are associated with VTE reoccurrence. A gradual increase in risk for all-cause death suggests that VTE is also an indicator of biologically more aggressive cancer types and advanced cancer stages. Considering the lack of standardization for D-dimer assays, it is essential for clinicians to carefully consider the variations in assay performance and the specific test characteristics of their institution. CONCLUSIONS: Standardizing D-dimer assays and developing modified pretest probability models specifically for cancer patients, along with adjusted cut-off values for D-dimer testing, could significantly enhance the accuracy and effectiveness of VTE diagnosis in this population.


Assuntos
Produtos de Degradação da Fibrina e do Fibrinogênio , Neoplasias , Humanos , Neoplasias/sangue , Neoplasias/complicações , Neoplasias/diagnóstico , Valor Preditivo dos Testes , Fatores de Risco , Tromboembolia Venosa/sangue , Tromboembolia Venosa/diagnóstico , Tromboembolia Venosa/prevenção & controle , Bioensaio/normas , Sensibilidade e Especificidade
10.
Eur Radiol ; 33(9): 6339-6350, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37000215

RESUMO

OBJECTIVES: The purpose of this study was to evaluate the diagnostic accuracy of third-generation dual-source dual-energy CT (DECT) color-coded collagen reconstructions for the assessment of the cruciate ligaments compared to standard grayscale image reconstruction. METHODS: Patients who underwent third-generation dual-source DECT followed by either 3-T MRI or arthroscopy of the knee joint within 14 days between January 2016 and December 2021 were included in this retrospective study. Five radiologists independently evaluated conventional grayscale DECT for the presence of injury to the cruciate ligaments; after 4 weeks, readers re-evaluated the examinations using grayscale images and color-coded collagen reconstructions. A reference standard for MRI was provided by a consensus reading of two experienced readers and arthroscopy. Sensitivity and specificity were the primary metrics of diagnostic performance. RESULTS: Eighty-five patients (mean age, 44 years ± 16; 50 male) with injury to the ACL or PCL (n = 31) were ultimately included. Color-coded collagen reconstructions significantly increased overall sensitivity (94/105 [90%] vs. 67/105 [64%]), specificity (248/320 [78%] vs. 215/320 [67%]), PPV (94/166 [57%] vs. 67/162 [39%]), NPV (248/259 [96%] vs. 215/253 [85%]), and accuracy (342/425 [81%] vs. 282/425 [66%]) for the detection of injury to the anterior cruciate ligament (all parameters, p < .001). For injury to the posterior cruciate ligament, diagnostic accuracy increased for complete tears (p < .001). Color-coded collagen reconstructions achieved superior diagnostic confidence, image quality, and noise scores compared to grayscale CT (all parameters, p < .001) and showed good agreement with MRI examinations. CONCLUSIONS: DECT-derived color-coded collagen reconstructions yield substantially higher diagnostic accuracy and confidence for assessing the integrity of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. KEY POINTS: • Color-coded collagen reconstructions derived from dual-energy CT yield substantially higher diagnostic accuracy and confidence for the assessment of the cruciate ligaments compared to standard grayscale CT in patients with acute trauma. • Color-coded collagen reconstructions demonstrate good agreement with MRI for the assessment cruciate ligament injury. • Dual-energy CT may serve as a readily available screening approach for patients with acute trauma to the knee when injury to the cruciate ligaments is suspected.


Assuntos
Lesões do Ligamento Cruzado Anterior , Tomografia Computadorizada por Raios X , Humanos , Masculino , Adulto , Estudos Retrospectivos , Tomografia Computadorizada por Raios X/métodos , Articulação do Joelho , Ligamento Cruzado Anterior , Colágeno , Lesões do Ligamento Cruzado Anterior/diagnóstico por imagem , Sensibilidade e Especificidade , Imageamento por Ressonância Magnética/métodos
11.
J Appl Clin Med Phys ; 24(2): e13860, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36565180

RESUMO

This prospective study sought to evaluate potential savings of radiation dose to medical staff using real-time dosimetry coupled with visual radiation dose feedback during angiographic interventions. For this purpose, we analyzed a total of 214 angiographic examinations that consisted of chemoembolizations and several other types of therapeutic interventions. The Unfors RaySafe i2 dosimeter was worn by the interventionalist at chest height over the lead protection. A total of 110 interventions were performed with real-time radiation dosimetry allowing the interventionalist to react upon higher x-ray exposure and 104 examinations served as the comparative group without real-time radiation monitoring. By using the real-time display during interventions, the overall mean operator radiation dose decreased from 3.67 (IQR, 0.95-23.01) to 2.36 µSv (IQR, 0.52-12.66) (-36%; p = 0.032) at simultaneously reduced operator exposure time by 4.5 min (p = 0.071). Dividing interventions into chemoembolizations and other types of therapeutic interventions, radiation dose decreased from 1.31 (IQR, 0.46-3.62) to 0.95 µSv (IQR, 0.53-3.11) and from 24.39 (IQR, 12.14-63.0) to 10.37 µSv (IQR, 0.85-36.84), respectively, using live-screen dosimetry (p ≤ 0.005). Radiation dose reductions were also observed for the participating assistants, indicating that they could also benefit from real-time visual feedback dosimetry during interventions (-30%; p = 0.039). Integration of real-time dosimetry into clinical processes might be useful in reducing occupational radiation exposure time during angiographic interventions. The real-time visual feedback raised the awareness of interventionalists and their assistants to the potential danger of prolonged radiation exposure leading to the adoption of radiation-sparing practices. Therefore, it might create a safer environment for the medical staff by keeping the applied radiation exposure as low as possible.


Assuntos
Exposição Ocupacional , Exposição à Radiação , Lesões por Radiação , Humanos , Doses de Radiação , Estudos Prospectivos , Retroalimentação Sensorial , Radiometria , Lesões por Radiação/prevenção & controle , Exposição à Radiação/prevenção & controle , Exposição Ocupacional/prevenção & controle , Radiografia Intervencionista , Fluoroscopia
12.
Eur Radiol ; 32(5): 3076-3084, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-34713330

RESUMO

OBJECTIVES: To evaluate the predictive value of volumetric bone mineral density (BMD) assessment of the lumbar spine derived from phantomless dual-energy CT (DECT)-based volumetric material decomposition as an indicator for the 2-year occurrence risk of osteoporosis-associated fractures. METHODS: L1 of 92 patients (46 men, 46 women; mean age, 64 years, range, 19-103 years) who had undergone third-generation dual-source DECT between 01/2016 and 12/2018 was retrospectively analyzed. For phantomless BMD assessment, dedicated DECT postprocessing software using material decomposition was applied. Digital files of all patients were sighted for 2 years following DECT to obtain the incidence of osteoporotic fractures. Receiver operating characteristic (ROC) analysis was used to calculate cut-off values and logistic regression models were used to determine associations of BMD, sex, and age with the occurrence of osteoporotic fractures. RESULTS: A DECT-derived BMD cut-off of 93.70 mg/cm3 yielded 85.45% sensitivity and 89.19% specificity for the prediction to sustain one or more osteoporosis-associated fractures within 2 years after BMD measurement. DECT-derived BMD was significantly associated with the occurrence of new fractures (odds ratio of 0.8710, 95% CI, 0.091-0.9375, p < .001), indicating a protective effect of increased DECT-derived BMD values. Overall AUC was 0.9373 (CI, 0.867-0.977, p < .001) for the differentiation of patients who sustained osteoporosis-associated fractures within 2 years of BMD assessment. CONCLUSIONS: Retrospective DECT-based volumetric BMD assessment can accurately predict the 2-year risk to sustain an osteoporosis-associated fracture in at-risk patients without requiring a calibration phantom. Lower DECT-based BMD values are strongly associated with an increased risk to sustain fragility fractures. KEY POINTS: •Dual-energy CT-derived assessment of bone mineral density can identify patients at risk to sustain osteoporosis-associated fractures with a sensitivity of 85.45% and a specificity of 89.19%. •The DECT-derived BMD threshold for identification of at-risk patients lies above the American College of Radiology (ACR) QCT guidelines for the identification of osteoporosis (93.70 mg/cm3 vs 80 mg/cm3).


Assuntos
Osteoporose , Fraturas por Osteoporose , Absorciometria de Fóton , Adulto , Idoso , Idoso de 80 Anos ou mais , Densidade Óssea , Feminino , Humanos , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Osteoporose/complicações , Osteoporose/diagnóstico por imagem , Osteoporose/epidemiologia , Fraturas por Osteoporose/diagnóstico por imagem , Fraturas por Osteoporose/epidemiologia , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Adulto Jovem
13.
Eur Radiol ; 32(4): 2168-2177, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-34820684

RESUMO

OBJECTIVES: To investigate the diagnostic accuracy of color-coded contrast-enhanced dual-energy CT virtual noncalcium (VNCa) reconstructions for the assessment of lumbar disk herniation compared to unenhanced VNCa imaging. METHODS: A total of 91 patients were retrospectively evaluated (65 years ± 16; 43 women) who had undergone third-generation dual-source dual-energy CT and 3.0-T MRI within an examination interval up to 3 weeks between November 2019 and December 2020. Eight weeks after assessing unenhanced color-coded VNCa reconstructions for the presence and degree of lumbar disk herniation, corresponding contrast-enhanced portal venous phase color-coded VNCa reconstructions were independently analyzed by the same five radiologists. MRI series were additionally analyzed by one highly experienced musculoskeletal radiologist and served as reference standard. RESULTS: MRI depicted 210 herniated lumbar disks in 91 patients. VNCa reconstructions derived from contrast-enhanced CT scans showed similar high overall sensitivity (93% vs 95%), specificity (94% vs 95%), and accuracy (94% vs 95%) for the assessment of lumbar disk herniation compared to unenhanced VNCa images (all p > .05). Interrater agreement in VNCa imaging was excellent for both, unenhanced and contrast-enhanced CT (κ = 0.84 vs κ = 0.86; p > .05). Moreover, ratings for diagnostic confidence, image quality, and noise differed not significantly between unenhanced and contrast-enhanced VNCa series (all p > .05). CONCLUSIONS: Color-coded VNCa reconstructions derived from contrast-enhanced dual-energy CT yield similar diagnostic accuracy for the depiction of lumbar disk herniation compared to unenhanced VNCa imaging and therefore may improve opportunistic retrospective lumbar disk herniation assessment, particularly in case of staging CT examinations. KEY POINTS: • Color-coded dual-source dual-energy CT virtual noncalcium (VNCa) reconstructions derived from portal venous phase yield similar high diagnostic accuracy for the assessment of lumbar disk herniation compared to unenhanced VNCa CT series (94% vs 95%) with MRI serving as a standard of reference. • Diagnostic confidence, image quality, and noise levels differ not significantly between unenhanced and contrast-enhanced portal venous phase VNCa dual-energy CT series. • Dual-source dual-energy CT might have the potential to improve opportunistic retrospective lumbar disk herniation assessment in CT examinations performed for other indications through reconstruction of VNCa images.


Assuntos
Deslocamento do Disco Intervertebral , Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Medula Óssea , Edema , Feminino , Humanos , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Estudos Retrospectivos , Sensibilidade e Especificidade , Tomografia Computadorizada por Raios X/métodos
14.
Eur Radiol ; 31(12): 9221-9231, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34076743

RESUMO

OBJECTIVES: To determine the diagnostic accuracy of dual-energy CT (DECT) virtual noncalcium (VNCa) reconstructions for assessing thoracic disk herniation compared to standard grayscale CT. METHODS: In this retrospective study, 87 patients (1131 intervertebral disks; mean age, 66 years; 47 women) who underwent third-generation dual-source DECT and 3.0-T MRI within 3 weeks between November 2016 and April 2020 were included. Five blinded radiologists analyzed standard DECT and color-coded VNCa images after a time interval of 8 weeks for the presence and degree of thoracic disk herniation and spinal nerve root impingement. Consensus reading of independently evaluated MRI series served as the reference standard, assessed by two separate experienced readers. Additionally, image ratings were carried out by using 5-point Likert scales. RESULTS: MRI revealed a total of 133 herniated thoracic disks. Color-coded VNCa images yielded higher overall sensitivity (624/665 [94%; 95% CI, 0.89-0.96] vs 485/665 [73%; 95% CI, 0.67-0.80]), specificity (4775/4990 [96%; 95% CI, 0.90-0.98] vs 4066/4990 [82%; 95% CI, 0.79-0.84]), and accuracy (5399/5655 [96%; 95% CI, 0.93-0.98] vs 4551/5655 [81%; 95% CI, 0.74-0.86]) for the assessment of thoracic disk herniation compared to standard CT (all p < .001). Interrater agreement was excellent for VNCa and fair for standard CT (ϰ = 0.82 vs 0.37; p < .001). In addition, VNCa imaging achieved higher scores regarding diagnostic confidence, image quality, and noise compared to standard CT (all p < .001). CONCLUSIONS: Color-coded VNCa imaging yielded substantially higher diagnostic accuracy and confidence for assessing thoracic disk herniation compared to standard CT. KEY POINTS: • Color-coded VNCa reconstructions derived from third-generation dual-source dual-energy CT yielded significantly higher diagnostic accuracy for the assessment of thoracic disk herniation and spinal nerve root impingement compared to standard grayscale CT. • VNCa imaging provided higher diagnostic confidence and image quality at lower noise levels compared to standard grayscale CT. • Color-coded VNCa images may potentially serve as a viable imaging alternative to MRI under circumstances where MRI is unavailable or contraindicated.


Assuntos
Imagem Radiográfica a Partir de Emissão de Duplo Fóton , Tomografia Computadorizada por Raios X , Idoso , Medula Óssea , Edema , Feminino , Humanos , Estudos Retrospectivos , Sensibilidade e Especificidade
15.
Unfallchirurg ; 124(8): 621-626, 2021 Aug.
Artigo em Alemão | MEDLINE | ID: mdl-34374807

RESUMO

Hemorrhage after trauma in the area of the upper abdominal organs and the kidneys can represent a life-threatening situation. The primary treatment options are conservative or surgical treatment. Only in exceptional cases can endovascular treatment with an angiographic depiction of the active bleeding and, if necessary, intervention by means of embolization be used as an alternative.


Assuntos
Traumatismos Abdominais , Embolização Terapêutica , Traumatismos Abdominais/diagnóstico por imagem , Traumatismos Abdominais/cirurgia , Angiografia , Hemorragia/diagnóstico por imagem , Hemorragia/terapia , Humanos , Rim/diagnóstico por imagem , Estudos Retrospectivos , Resultado do Tratamento
16.
Eur Radiol ; 30(1): 141-150, 2020 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-31350586

RESUMO

OBJECTIVES: To evaluate the diagnostic accuracy of dual-energy computed tomography (CT) virtual non-calcium (VNCa) reconstructions for the depiction of traumatic knee bone marrow edema. METHODS: Fifty-seven patients (mean age, 50 years; range, 20-82 years) with acute knee trauma further divided into 30 women and 27 men, who had undergone third-generation dual-source dual-energy CT and 3-T magnetic resonance imaging (MRI) within 7 days between January 2017 and May 2018, were retrospectively analyzed. Six radiologists, blinded to clinical and MRI information, independently analyzed conventional grayscale dual-energy CT series for fractures; after 8 weeks, readers evaluated color-coded VNCa reconstructions for the presence of bone marrow edema in six femoral and six tibial regions. Quantitative analysis of CT numbers on VNCa reconstructions was performed by a seventh radiologist. Two additional radiologists, blinded to clinical and CT information, analyzed MRI series in consensus to define the reference standard. Sensitivity, specificity, and the area under the curve (AUC) were the primary metrics of diagnostic accuracy. RESULTS: MRI revealed 197 areas with bone marrow edema (91/342 femoral, 106/342 tibial). In the qualitative analysis, VNCa showed high overall sensitivity (1108/1182 [94%]) and specificity (2789/2922 [95%]) for depicting bone marrow edema. The AUC was 0.96 (femur) and 0.97 (tibia). A cutoff value of - 51 Hounsfield units (HU) provided high sensitivity (102/106 [96%]) and specificity (229/236 [97%]) for differentiating tibial bone marrow edema. CONCLUSIONS: In both quantitative and qualitative analyses, dual-energy CT VNCa reconstructions yielded excellent diagnostic accuracy for depicting traumatic knee bone marrow edema compared with MRI. KEY POINTS: • Dual-energy CT (DECT) virtual non-calcium (VNCa) reconstructions are highly accurate in depicting bone marrow edema of the femur and tibia. • Diagnostic confidence, image noise, and image quality were rated as equivalent in VNCa reconstructions and MRI (magnetic resonance imaging) series. • VNCa images may serve as an alternative imaging approach to MRI.


Assuntos
Doenças da Medula Óssea/patologia , Edema/patologia , Fraturas Ósseas/patologia , Traumatismos do Joelho , Tomografia Computadorizada por Raios X/métodos , Doença Aguda , Adulto , Idoso , Idoso de 80 Anos ou mais , Cálcio , Feminino , Humanos , Traumatismos do Joelho/diagnóstico por imagem , Traumatismos do Joelho/patologia , Articulação do Joelho/patologia , Imageamento por Ressonância Magnética/métodos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade , Tíbia/patologia , Adulto Jovem
17.
Radiology ; 290(2): 446-455, 2019 02.
Artigo em Inglês | MEDLINE | ID: mdl-30615548

RESUMO

Purpose To assess the diagnostic performance of dual-energy CT with reconstruction of virtual noncalcium (VNCa) images for the detection of lumbar disk herniation compared with standard CT image reconstruction. Materials and Methods For this retrospective study, 41 patients (243 intervertebral disks; overall mean age, 68 years; 24 women [mean age, 68 years] and 17 men [mean age, 68 years]) underwent clinically indicated third-generation, dual-source, dual-energy CT and 3.0-T MRI within 2 weeks between March 2017 and January 2018. Six radiologists, blinded to clinical and MRI information, independently evaluated conventional gray-scale dual-energy CT series for the presence and degree of lumbar disk herniation and spinal nerve root impingement. After 8 weeks, readers reevaluated examinations by using color-coded VNCa reconstructions. MRI evaluated by two separate experienced readers, blinded to clinical and dual-energy CT information, served as the standard of reference. Sensitivity and specificity were the primary metrics of diagnostic performance. Results A total of 112 herniated lumbar disks were depicted at MRI. VNCa showed higher overall sensitivity (612 of 672 [91%] vs 534 of 672 [80%]) and specificity (723 of 786 [92%] vs 665 of 786 [85%]) for detecting lumbar disk herniation compared with standard CT (all comparisons, P < .001). Interreader agreement was excellent for VNCa and substantial for standard CT (κ = 0.82 vs 0.67; P < .001). VNCa achieved superior diagnostic confidence, image quality, and noise scores compared with standard CT (all comparisons, P < .001). Conclusion Color-coded dual-energy CT virtual noncalcium reconstructions show substantially higher diagnostic performance and confidence for depicting lumbar disk herniation compared with standard CT. © RSNA, 2018.


Assuntos
Degeneração do Disco Intervertebral/diagnóstico por imagem , Deslocamento do Disco Intervertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/métodos , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Disco Intervertebral/diagnóstico por imagem , Vértebras Lombares/diagnóstico por imagem , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
18.
Minim Invasive Ther Allied Technol ; 28(6): 373-380, 2019 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-30428741

RESUMO

Purpose: To assess the accuracy and time requirements of image-guided percutaneous K-wire insertion in the spine using an advanced robot assistance device for needle guidance and to demonstrate a radiation-free workflow for the physician. Material and methods: A planning CT-scan was acquired of a cadaver specimen and analyzed using a 3D-interventional software integrated in the robotic device. The optimal needle path was simulated and the needle holder of the robot was used for guidance during K-wire insertion. Twenty-four K-wires were inserted percutaneously in a transpedicular approach in the following vertebrae: thoracic (T) 2, 7-12 and lumbar (L) 1-5. A post-procedural CT scan was performed to analyze the accuracy of the K-wire insertion. Results: All procedures were carried out without any perforation of the pedicle wall. The mean duration of planning the intervention path was 2:54 ± 2:22 min, mean positioning time was 2:04 ± 0:42 min and the mean time for K-wire insertion was 2:13 ± 0:54 min. In total, the average intervention time was 7:10 ± 3:06 min per pedicle. Compared to the planning, the K-wire position showed a mean deviation of 0.5 mm in the vertical-axis and 1.2 mm in the horizontal-axis. The average intervention path length was 8.1 cm. Conclusion: Our findings show a high accuracy in robot-assisted K-wire insertion during spinal interventions without any exposure of the operator to radiation.


Assuntos
Vértebras Lombares/cirurgia , Robótica , Tomografia Computadorizada por Raios X , Fios Ortopédicos , Humanos , Cirurgia Assistida por Computador/métodos
19.
BMC Cancer ; 18(1): 188, 2018 02 14.
Artigo em Inglês | MEDLINE | ID: mdl-29444653

RESUMO

BACKGROUND: To evaluate survival data and local tumor control after transarterial chemoembolization in two groups with different embolization protocols for the treatment of HCC patients. METHODS: Ninty-nine patients (mean age: 63.6 years), 78 male (78.8%) with HCC were repeatedly treated with chemoembolization in 4-week-intervals. Eighty-eight patients had BCLC-Stage-B and in 11 patients, chemoembolization was performed for bridging (BCLC-Stage-A). In total, 667 chemoembolization treatments were performed (mean 6.7 treatments/patient). The administered chemotherapeutic agent included mitomycin. For embolization, lipiodol only (n = 51;51.5%; mean age 63.8 years; 38 male), or lipiodol plus degradable starch microspheres (DSM) (n = 48; 48.5%; mean age 63.4 years; 40 male) were used. The local tumor response was assessed by MRI using Response Evaluation Criteria in Solid Tumors 1.1 (RECIST 1.1). Patient survival times were evaluated using Kaplan-Meier curves and log-rank tests. RESULTS: The local tumor control in the lipiodol-group was: PR (partial response) in 11 (21.6%), SD (stable disease) in 32 (62.7%) and PD (progressive disease) in 8 cases (15.7%). In the lipiodol-DSM-group, PR was seen in 14 (29.2%), SD in 22 (45.8%), and PD in 12 (25.0%) individuals (p = 0.211). The median survival of patients after chemoembolization with lipiodol was 25 months and in the lipiodol-DSM-group 28 months (p = 0.845). CONCLUSION: Our data suggest a slight benefit of the use of lipiodol and DSM in comparison of using lipiodol only for chemoembolization of HCC in terms of local tumor control and survival data, this trend did not reach the level of significance.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Carcinoma Hepatocelular/tratamento farmacológico , Quimioembolização Terapêutica , Sistemas de Liberação de Medicamentos , Neoplasias Hepáticas/tratamento farmacológico , Microesferas , Amido , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Hepatocelular/diagnóstico , Carcinoma Hepatocelular/mortalidade , Quimioembolização Terapêutica/métodos , Óleo Etiodado/administração & dosagem , Feminino , Humanos , Estimativa de Kaplan-Meier , Neoplasias Hepáticas/diagnóstico , Neoplasias Hepáticas/mortalidade , Imageamento por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Mitomicina/administração & dosagem , Estadiamento de Neoplasias , Amido/química , Resultado do Tratamento
20.
Digestion ; 98(4): 263-269, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-30130797

RESUMO

BACKGROUND: Initially unresectable colorectal liver metastases can become resectable after chemotherapy. Combination chemotherapy with epidermal growth factor receptor (EGFR) antibodies has shown consistent high response rates in patients with all rat sarcoma (RAS) wild-type tumors. METHODS: Out of a cohort of 424 patients with metastatic colorectal cancer, we identified 30 patients with initially unresectable Kirsten RAS (KRAS) exon 2 wild-type colorectal liver metastases who received neoadjuvant chemotherapy with anti-EGFR agents between January 2008 and February 2014. In all patients, extended RAS analysis (KRAS and NRAS exon 3 codon 59/61 and exon 4 codon 117/146) was carried out retrospectively. RESULTS: RAS mutation analysis identified further KRAS mutations in 4/30 patients (13.3%). In none of these 4 patients a R0 resection was achieved. In contrast, 15/26 (57.7%) RAS wild-type patients were R0 resected. Median overall survival was > 63.3 months in R0-resected patients versus 30.0 months in those with a R1 or R2 resection (HR 0.23; [95% CI 0.10-0.75; p = 0.008). CONCLUSION: Our data suggest that a RAS wild-type and a R0 resection are the strongest predictors for overall survival.


Assuntos
Protocolos de Quimioterapia Combinada Antineoplásica/farmacologia , Neoplasias Colorretais/terapia , Hepatectomia/estatística & dados numéricos , Neoplasias Hepáticas/terapia , Carga Tumoral/efeitos dos fármacos , Protocolos de Quimioterapia Combinada Antineoplásica/uso terapêutico , Neoplasias Colorretais/genética , Neoplasias Colorretais/mortalidade , Neoplasias Colorretais/patologia , Análise Mutacional de DNA/métodos , Receptores ErbB/antagonistas & inibidores , Éxons/genética , Feminino , GTP Fosfo-Hidrolases/genética , Humanos , Fígado/efeitos dos fármacos , Fígado/cirurgia , Neoplasias Hepáticas/genética , Neoplasias Hepáticas/mortalidade , Neoplasias Hepáticas/secundário , Masculino , Proteínas de Membrana/genética , Pessoa de Meia-Idade , Mutação , Terapia Neoadjuvante/métodos , Proteínas Proto-Oncogênicas p21(ras)/genética , Estudos Retrospectivos , Análise de Sobrevida , Carga Tumoral/genética
SELEÇÃO DE REFERÊNCIAS