1.
J Appl Clin Med Phys ; 18(3): 96-107, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-28422381

RESUMO

PURPOSE: Commissioning beam data for proton spot scanning beams are compared for the first two Varian ProBeam sites in the United States, at the Maryland Proton Treatment Center (MPTC) and Scripps Proton Therapy Center (SPTC). In addition, the extent to which beams can be matched between gantry rooms at MPTC is investigated. METHOD: Beam data for the two sites were acquired with independent dosimetry systems and compared. Integrated depth dose curves (IDDs) were acquired with Bragg peak ion chambers in a 3D water tank for pencil beams at both sites. Spot profiles were acquired at different distances from the isocenter at a gantry angle of 0° as well as a function of gantry angles. Absolute dose calibration was compared between SPTC and the gantries at MPTC. Dosimetric verification of test plans, output as a function of gantry angle, monitor unit (MU) linearity, end effects, dose rate dependence, and plan reproducibility were compared for different gantries at MPTC. RESULTS: The IDDs for the two sites were similar, except in the plateau region, where the SPTC data were on average 4.5% higher for lower energies. This increase in the plateau region decreased as energy increased, with no marked difference for energies higher than 180 MeV. Range in water coincided for all energies within 0.5 mm. The sigmas of the spot profiles in air were within 10% agreement at isocenter. This difference increased as detector distance from the isocenter increased. Absolute doses for the gantries measured at both sites were within 1% agreement. Test plans, output as function of gantry angle, MU linearity, end effects, dose rate dependence, and plan reproducibility were all within tolerances given by TG142. CONCLUSION: Beam data for the two sites and between different gantry rooms were well matched.


Assuntos
Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Radiometria , Dosagem Radioterapêutica , Calibragem , Reprodutibilidade dos Testes
2.
Adv Radiat Oncol ; 9(3): 101415, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38379892

RESUMO

Purpose: The nervous system is vulnerable to radiation damage, and further optimization is required to increase the efficacy of radiation therapy while reducing harm to neurons. Given recent developments in heavy ion therapy, experimental models would be valuable to improve these therapies. We used the nematode Caenorhabditis elegans (C. elegans) to evaluate the effects of high-dose radiation on neuron development. Methods and Materials: In this study, we used confocal microscopy to assess dendritic growth of the PVD nociceptor after high-dose gamma-irradiation from a Cs-137 source. Results: Irradiation during an early larval stage (L2) delayed overall development but also independently impaired dendrite outgrowth in the PVD nociceptive neuron. Irradiation at L4 larval stage did not result in significant alterations in dendrite morphology. Conclusions: The nematode C. elegans can serve as a high-throughput model to study the effects of high-dose radiation on dendrite growth. We propose that C. elegans can be useful for studies of experimental radiation therapy modalities and dose rates for translational research.

4.
Med Phys ; 38(12): 6610-22, 2011 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-22149843

RESUMO

PURPOSE: The purpose of this work was to investigate the potential of discrete Gaussian edge feathering of the higher energy electron fields for improving abutment dosimetry in the planning volume when using an electron multileaf collimator (eMLC) to deliver segmented-field electron conformal therapy (ECT). METHODS: A discrete (five-step) Gaussian edge spread function was used to match dose penumbras of differing beam energies (6-20 MeV) at a specified depth in a water phantom. Software was developed to define the leaf eMLC positions of an eMLC that most closely fit each electron field shape. The effect of 1D edge feathering of the higher energy field on dose homogeneity was computed and measured for segmented-field ECT treatment plans for three 2D PTVs in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of the x-axis (parallel to leaf motion) and remained constant along the y-axis (perpendicular to leaf motion). Additionally, the effect of 2D edge feathering was computed and measured for one radially symmetric, 3D PTV in a water phantom, i.e., depth from the water surface to the distal PTV surface varied as a function of both axes. For the 3D PTV, the feathering scheme was evaluated for 0.1-1.0-cm leaf widths. Dose calculations were performed using the pencil beam dose algorithm in the Pinnacle(3) treatment planning system. Dose verification measurements were made using a prototype eMLC (1-cm leaf width). RESULTS: 1D discrete Gaussian edge feathering reduced the standard deviation of dose in the 2D PTVs by 34, 34, and 39%. In the 3D PTV, the broad leaf width (1 cm) of the eMLC hindered the 2D application of the feathering solution to the 3D PTV, and the standard deviation of dose increased by 10%. However, 2D discrete Gaussian edge feathering with simulated eMLC leaf widths of 0.1-0.5 cm reduced the standard deviation of dose in the 3D PTV by 33-28%, respectively. CONCLUSIONS: A five-step discrete Gaussian edge spread function applied in 2D improves the abutment dosimetry but requires an eMLC leaf resolution better than 1 cm.


Assuntos
Radiometria/instrumentação , Radiometria/métodos , Radioterapia Conformacional/instrumentação , Radioterapia Conformacional/métodos , Algoritmos , Análise por Conglomerados , Desenho Assistido por Computador , Elétrons/uso terapêutico , Desenho de Equipamento , Análise de Falha de Equipamento , Estudos de Viabilidade , Aprendizagem , Distribuição Normal , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Cancers (Basel) ; 13(24)2021 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-34944825

RESUMO

The purpose of this work was to investigate whether minibeam therapy with heavy ions might offer improvements of the therapeutic ratio for the treatment of human brain cancers. To assess neurotoxicity, we irradiated normal juvenile rats using 120 MeV lithium-7 ions at an absorbed integral dose of 20 Gy. Beams were configured either as a solid parallel circular beam or as an array of planar parallel minibeams having 300-micron width and 1-mm center-to-center spacing within a circular array. We followed animals for 6 months after treatment and utilized behavioral testing and immunohistochemical studies to investigate the resulting cognitive impairment and chronic pathologic changes. We found both solid-beam therapy and minibeam therapy to result in cognitive impairment compared with sham controls, with no apparent reduction in neurotoxicity using heavy ion minibeams instead of solid beams under the conditions of this study.

6.
Int J Radiat Biol ; 97(12): 1675-1686, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34495790

RESUMO

PURPOSE: Chordoma is a locally aggressive tumor that most commonly affects the base of the skull/clivus, cervical, and sacral spine. Conventional radiotherapy (RT), cannot be safely increased further to improve disease control due to the risk of toxicity to the surrounding critical structures. Tumor-targeted hyperthermia (HT) combined with Proton Beam Radiation Therapy (PBRT) is known to act as a potent radiosensitizer in cancer control. In this study, we investigated whether PBRT efficacy for chordoma can be enhanced in combination with HT as a radiosensitizer. MATERIAL AND METHODS: Human chordoma cell lines, U-CH2 and Mug-chor1 were treated in vitro with HT followed by PBRT with variable doses. The colony-forming assay was performed, and dose-response was characterized by linear-quadratic model fits. HSP-70 and Brachyury (TBXT) biomarkers for chordoma aggression levels were quantified by western blot analysis. Gene microarray analysis was performed by U133 Arrays. Pathway Analysis was also performed using IPA bioinformatic software. RESULTS: Our findings in both U-CH2 and Mug-Chor1 cell lines demonstrate that hyperthermia followed by PBRT has an enhanced cell killing effect when compared with PBRT-alone (p < .01). Western blot analysis showed HT decreased the expression of Brachyury protein (p < .05), which is considered a biomarker for chordoma tumor aggression. HT with PBRT also exhibited an RT-dose-dependent decrease of Brachyury expression (p < .05). We also observed enhanced HSP-70 expression due to HT, RT, and HT + RT combined in both cell lines. Interestingly, genomic data showed 344 genes expressed by the treatment of HT + RT compared to HT (68 genes) or RT (112 genes) as individual treatment. We also identified activation of death receptor and apoptotic pathway in HT + RT treated cells. CONCLUSION: We found that Hyperthermia (HT) combined with Proton Beam Radiation (PBRT) could significantly increase chordoma cell death by activating the death receptor pathway and apoptosis which has the promise to treat metastatic chordoma.


Assuntos
Cordoma , Hipertermia Induzida , Terapia com Prótons , Radiossensibilizantes , Apoptose , Cordoma/radioterapia , Humanos , Prótons , Receptores de Morte Celular
7.
PLoS One ; 16(11): e0258951, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34762666

RESUMO

Radiation therapy plays a major role in the treatment of lung cancer patients. However, cancer cells develop resistance to radiation. Tumor radioresistance is a complex multifactorial mechanism which may be dependent on DNA damage and repair, hypoxic conditions inside tumor microenvironment, and the clonal selection of radioresistant cells from the heterogeneous tumor site, and it is a major cause of treatment failure in non-small cell lung cancer (NSCLC). In the present investigation caveolin-1 (CAV-1) has been observed to be highly expressed in radiation resistant A549 lung cancer cells. CRISPR-Cas9 knockout of CAV-1 reverted the cells to a radio sensitive phenotype. In addition, CAV-1 overexpression in parental A549 cells, led to radiation resistance. Further, gene expression analysis of A549 parental, radiation resistant, and caveolin-1 overexpressed cells, exhibited overexpression of DNA repair genes RAD51B, RAD18, SOX2 cancer stem cell marker, MMPs, mucins and cytoskeleton proteins in resistant and caveolin-1 over expressed A549 cells, as compared to parental A549 cells. Bioinformatic analysis shows upregulation of BRCA1, Nuclear Excision DNA repair, TGFB and JAK/STAT signaling pathways in radioresistant and caveolin-1 overexpressed cells, which may functionally mediate radiation resistance. Immunohistochemistry data demonstrated heterogeneous expression of CAV-1 gene in human lung cancer tissues, which was analogous to its enhanced expression in human lung cancer cell line model and mouse orthotopic xenograft lung cancer model. Also, TCGA PanCancer clinical studies have demonstrated amplification, deletions and missense mutation in CAV-1 gene in lung cancer patients, and that CAV-1 alteration has been linked to poor prognosis, and poor survival in lung cancer patients. Interestingly, we have also optimized ELISA assay to measure caveolin-1 protein in the blood of A549 radiation resistant human xenograft preclinical mouse model and discovered higher level of caveolin-1 (950 pg/ml) in tumor bearing animals treated with radiation, as compared to xenograft with radiosensitive lung cancer cells (450 pg/ml). Thus, we conclude that caveolin-1 is involved in radio-resistance and contributes to tumor aggression, and it has potential to be used as prognostic biomarker for radiation treatment response, and tumor progression for precision medicine in lung cancer patients.


Assuntos
Biomarcadores Tumorais/metabolismo , Caveolina 1/metabolismo , Neoplasias Pulmonares/patologia , Tolerância a Radiação , Células A549 , Animais , Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/patologia , Caveolina 1/genética , Reparo do DNA/genética , Dosagem de Genes , Perfilação da Expressão Gênica , Regulação Neoplásica da Expressão Gênica , Humanos , Neoplasias Pulmonares/genética , Camundongos Endogâmicos BALB C , Camundongos Nus , Análise em Microsséries , Invasividade Neoplásica , Células-Tronco Neoplásicas/metabolismo , Células-Tronco Neoplásicas/patologia , Prognóstico , Mapas de Interação de Proteínas/genética , Regulação para Cima/genética , Ensaios Antitumorais Modelo de Xenoenxerto
8.
Cancers (Basel) ; 13(23)2021 Dec 04.
Artigo em Inglês | MEDLINE | ID: mdl-34885223

RESUMO

BACKGROUND: Chordoma is a cancer of spinal cord, skull base, and sacral area. Currently, the standard of care to treat chordoma is resection followed by radiation therapy. Since, chordoma is present in the spinal cord and these are very sensitive structures and often complete removal by surgery is not possible. As a result, chordoma has a high chance of recurrence and developing resistance to radiation therapy. In addition, treatment of chordoma by conventional radiation therapy can also damage normal tissues surrounding chordoma. Thus, current therapeutic options to treat chordoma are insufficient and novel therapies are desperately needed to treat locally advanced and metastatic chordoma. (2) Methods: In the present investigation, human chordoma cell lines of sacral origin MUG-Chor1 and U-CH2 were cultured and irradiated with Proton Beam Radiation using the clinical superconducting cyclotron and pencil-beam (active) scanning at Middle and End of the Spread-Out Bragg Peak (SOBP). Proton radiation was given at the following doses: Mug-Chor1 at 0, 1, 2, 4, and 8 Gy and U-CH2 at 0, 4, 8, 12, and 16 Gy. These doses were selected based on a pilot study in our lab and attempted to produce approximate survival fractions in the range of 1, 0.9, 0.5, 0.1, and 0.01, respectively, chosen for linear quadratic model fitting of the dose response. (3) Results: In this study, we investigated relative biological effectiveness (RBE) of proton radiation at the end of Spread Out Bragg Peak assuming that the reference radiation is a proton radiation in the middle of the SOBP. We observed differences in the survival of both Human chordoma cell lines, U-CH2 and MUG-Chor1. The data showed that there was a significantly higher cell death at the end of the Bragg peak as compared to middle of the Bragg peak. Based on the linear quadratic (LQ) fit for cell survival we calculated the RBE between M-SOBP and E-SOBP at 95% CI level and it was observed that RBE was higher than 1 at E-SOBP and caused significantly higher cell killing. Proton field at E-SOBP caused complex DNA damage in comparison to M-EOBP and the genes such as DNA topoisomerase 1, GTSE1, RAD51B were downregulated in E-SOBP treated cells. Thus, we conclude that there seems to be substantial variation in RBE (1.3-1.7) at the E-SOBP compared with the M-SOBP.

9.
Sci Rep ; 10(1): 11368, 2020 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-32647361

RESUMO

Proton minibeams (MBs) comprised of parallel planar beamlets were evaluated for their ability to spare healthy brain compared to proton broad beams (BBs). Juvenile mice were given partial brain irradiation of 10 or 30 Gy integral dose using 100 MeV protons configured either as BBs or arrays of 0.3-mm planar MBs spaced 1.0 mm apart on center. Neurologic toxicity was evaluated during an 8-month surveillance: no overt constitutional or neurologic dysfunction was noted for any study animals. Less acute epilation was observed in MB than BB mice. Persistent chronic inflammation was noted along the entire BB path in BB mice whereas inflammation was confined to just within the MB peak regions in MB mice. The potential neurologic sparing, possibly via reduced volume of chronic inflammation, offers a compelling rationale for clinical advancement of this proton technique.


Assuntos
Neoplasias Encefálicas/radioterapia , Encéfalo/efeitos da radiação , Tratamentos com Preservação do Órgão/efeitos adversos , Terapia com Prótons/efeitos adversos , Lesões Experimentais por Radiação/diagnóstico , Animais , Técnicas de Observação do Comportamento , Comportamento Animal/efeitos da radiação , Encéfalo/patologia , Encéfalo/fisiopatologia , Cognição/fisiologia , Cognição/efeitos da radiação , Humanos , Masculino , Camundongos , Testes Neuropsicológicos , Tratamentos com Preservação do Órgão/instrumentação , Tratamentos com Preservação do Órgão/métodos , Projetos Piloto , Terapia com Prótons/instrumentação , Terapia com Prótons/métodos , Lesões Experimentais por Radiação/etiologia , Lesões Experimentais por Radiação/patologia , Lesões Experimentais por Radiação/fisiopatologia , Dosagem Radioterapêutica
10.
Br J Radiol ; 93(1107): 20190332, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31944824

RESUMO

Proton minibeam therapy (PMBT) is a form of spatially fractionated radiotherapy wherein broad beam radiation is replaced with segmented minibeams-either parallel, planar minibeam arrays generated by a multislit collimator or scanned pencil beams that converge laterally at depth to create a uniform dose layer at the tumor. By doing so, the spatial pattern of entrance dose is considerably modified while still maintaining tumor dose and efficacy. Recent studies using computational modeling, phantom experiments, in vitro and in vivo preclinical models, and early clinical feasibility assessments suggest that unique physical and biological attributes of PMBT can be exploited for future clinical benefit. We outline some of the guiding principle of PMBT in this concise overview of this emerging area of preclinical and clinical research inquiry.


Assuntos
Criatividade , Neoplasias/radioterapia , Terapia com Prótons/métodos , Absorção de Radiação , Algoritmos , Fracionamento da Dose de Radiação , Estudos de Viabilidade , Humanos , Método de Monte Carlo , Tratamentos com Preservação do Órgão , Órgãos em Risco , Radiobiologia , Radiometria
11.
Br J Radiol ; 92(1095): 20180466, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30359081

RESUMO

Extraordinary normal tissue response to highly spatially fractionated X-ray beams has been explored for over 25 years. More recently, alternative radiation sources have been developed and utilized with the aim to evoke comparable effects. These include protons, which lend themselves well for this endeavour due to their physical depth dose characteristics as well as corresponding variable biological effectiveness. This paper addresses the motivation for using protons to generate spatially fractionated beams and reviews the technological implementations and experimental results to date. This includes simulation and feasibility studies, collimation and beam characteristics, dosimetry and biological considerations as well as the results of in vivo and in vitro studies. Experimental results are emerging indicating an extraordinary normal tissue sparing effect analogous to what has been observed for synchrotron generated X-ray microbeams. The potential for translational research and feasibility of spatially modulated proton beams in clinical settings is discussed.


Assuntos
Fracionamento da Dose de Radiação , Terapia com Prótons/métodos , Dosagem Radioterapêutica , Animais , Humanos , Radiometria/métodos
12.
Radiat Res ; 191(5): 428-438, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30870098

RESUMO

Detonation of a radiological or nuclear device in a major urban area will result in heterogenous radiation exposure, given to the significant shielding of the exposed population due to surrounding structures. Development of biodosimetry assays for triage and treatment requires knowledge of the radiation dose-volume effect for the bone marrow (BM). This proof-of-concept study was designed to quantify BM damage in the non-human primate (NHP) after exposure to one of four radiation patterns likely to occur in a radiological/nuclear attack with varying levels of BM sparing. Rhesus macaques (11 males, 12 females; 5.30-8.50 kg) were randomized by weight to one of four arms: 1. bilateral total-body irradiation (TBI); 2. unilateral TBI; 3. bilateral upper half-body irradiation (UHBI); and 4. bilateral lower half-body irradiation (LHBI). The match-point for UHBI vs. LHBI was set at 1 cm above the iliac crest. Animals were exposed to 4 Gy of 6 MV X rays. Peripheral blood samples were drawn 14 days preirradiation and at days 1, 3, 5, 7 and 14 postirradiation. Dosimetric measurements after irradiation indicated that dose to the mid-depth xiphoid was within 6% of the prescribed dose. No high-grade fever, weight loss >10%, dehydration or respiratory distress was observed. Animals in the bilateral- and unilateral TBI arms presented with hematologic changes [e.g., absolute neutrophil count (ANC) <500/ll; platelets <50,000/ll] and clinical signs/symptoms (e.g., petechiae, ecchymosis) characteristic of the acute radiation syndrome. Animals in the bilateral UHBI arm presented with myelosuppression; however, none of the animals developed severe neutropenia or thrombocytopenia (ANC remained >500/µl; platelets >50,000/µl during 14-day follow-up). In contrast, animals in the LHBI arm (1 cm above the ilieac crest to the toes) were protected against BM toxicity with no marked changes in hematological parameters and only minor gross pathology [petechiae (1/5), splenomegaly (1/5) and mild pulmonary hemorrhage (1/5)]. The model performed as expected with respect to the dose-volume effect of total versus partial-BM irradiation, e.g., increased shielding resulted in reduced BM toxicity. Shielding of the major blood-forming organs (e.g., skull, ribs, sternum, thoracic and lumbar spine) spared animals from bone marrow toxicity. These data suggest that the biological consequences of the absorbed dose are dependent on the total volume and pattern of radiation exposure.


Assuntos
Síndrome Aguda da Radiação/sangue , Testes Hematológicos , Síndrome Aguda da Radiação/patologia , Animais , Peso Corporal/efeitos da radiação , Modelos Animais de Doenças , Feminino , Macaca mulatta , Radiometria
13.
J Vis Exp ; (144)2019 02 06.
Artigo em Inglês | MEDLINE | ID: mdl-30799838

RESUMO

Radiation therapy is a frequently used modality for the treatment of solid cancers. Although the mechanisms of cell kill are similar for all forms of radiation, the in vivo properties of photon and proton beams differ greatly and maybe exploited to optimize clinical outcomes. In particular, proton particles lose energy in a predictable manner as they pass through the body. This property is used clinically to control the depth at which the proton beam is terminated, and to limit radiation dose beyond the target region. This strategy can allow for substantial reductions in radiation dose to normal tissues located just beyond a tumor target. However, the degradation of proton energy in the body remains highly sensitive to tissue density. As a consequence, any changes in tissue density during the course of treatment may significantly alter proton dosimetry. Such changes may occur through alterations in body weight, respiration, or bowel filling/gas, and may result in unfavorable dose deposition. In this manuscript, we provide a detailed method for the delivery of proton therapy using both passive scatter and pencil beam scanning techniques for prostate cancer. Although the described procedure directly pertains to prostate cancer patients, the method may be adapted and applied for the treatment of virtually all solid tumors. Our aim is to equip readers with a better understanding of proton therapy delivery and outcomes in order to facilitate the appropriate integration of this modality during cancer therapy.


Assuntos
Fótons/uso terapêutico , Neoplasias da Próstata/radioterapia , Terapia com Prótons/métodos , Radiometria/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Humanos , Masculino
14.
Int J Radiat Oncol Biol Phys ; 105(2): 400-409, 2019 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-31175904

RESUMO

PURPOSE: To assess whether BIO 300, a synthetic genistein nanosuspension, improves the therapeutic index in prostate cancer treatment by preventing radiation-induced erectile dysfunction (ED) without reducing tumor radiosensitivity. METHODS AND MATERIALS: Male Sprague-Dawley rats were exposed to 25 Gy of 220-kV prostate-confined x-rays. Animals were randomized to receive sham radiation therapy (RT), RT alone, RT with daily BIO 300 at 2 experimental dosing regimens, or RT with daily genistein. Erectile response was evaluated over time. Penile shaft tissue was harvested for histologic analyses. Murine xenograft studies using prostate cancer cell lines determined the effects of BIO 300 dosing on RT efficacy. RESULTS: Prostate-confined RT significantly decreased apomorphine-induced erectile response (P < .05 vs sham RT). Erection frequency in animals receiving prophylactic treatment with BIO 300 starting 3 days before RT was similar to sham controls after RT. Treatment with synthetic genistein did not mitigate loss in erectile frequency. At week 14, post-RT treatment with BIO 300 resulted in significantly higher quality of erectile function compared with both the RT arm and the RT arm receiving genistein starting 3 days before irradiation (P < .05). In hormone-sensitive and insensitive prostate tumor-bearing mice, BIO 300 administration did not negatively affect radiation-induced tumor growth delay. CONCLUSIONS: BIO 300 prevents radiation-induced ED, measured by erection frequency, erectile function, and erection quality, when administered 3 days before RT and continued daily for up to 14 weeks. Data also suggest that BIO 300 administered starting 2 hours after RT mitigates radiation-induced ED. Data provide strong nonclinical evidence to support clinical translation of BIO 300 for mitigation of ED while maintaining treatment response to RT.


Assuntos
Disfunção Erétil/prevenção & controle , Genisteína/uso terapêutico , Nanopartículas/uso terapêutico , Ereção Peniana/efeitos dos fármacos , Lesões Experimentais por Radiação/complicações , Protetores contra Radiação/uso terapêutico , Animais , Pressão Sanguínea , Modelos Animais de Doenças , Drogas em Investigação/uso terapêutico , Disfunção Erétil/etiologia , Fibrose , Masculino , Camundongos , Camundongos Nus , Ereção Peniana/efeitos da radiação , Pênis/irrigação sanguínea , Pênis/patologia , Próstata/efeitos da radiação , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Fluxo Sanguíneo Regional , Suspensões/uso terapêutico , Transplante Heterólogo
15.
Sci Rep ; 9(1): 1198, 2019 02 04.
Artigo em Inglês | MEDLINE | ID: mdl-30718607

RESUMO

Conventional radiation therapy of brain tumors often produces cognitive deficits, particularly in children. We investigated the potential efficacy of merging Orthovoltage X-ray Minibeams (OXM). It segments the beam into an array of parallel, thin (~0.3 mm), planar beams, called minibeams, which are known from synchrotron x-ray experiments to spare tissues. Furthermore, the slight divergence of the OXM array make the individual minibeams gradually broaden, thus merging with their neighbors at a given tissue depth to produce a solid beam. In this way the proximal tissues, including the cerebral cortex, can be spared. Here we present experimental results with radiochromic films to characterize the method's dosimetry. Furthermore, we present our Monte Carlo simulation results for physical absorbed dose, and a first-order biologic model to predict tissue tolerance. In particular, a 220-kVp orthovoltage beam provides a 5-fold sharper lateral penumbra than a 6-MV x-ray beam. The method can be implemented in arc-scan, which may include volumetric-modulated arc therapy (VMAT). Finally, OXM's low beam energy makes it ideal for tumor-dose enhancement with contrast agents such as iodine or gold nanoparticles, and its low cost, portability, and small room-shielding requirements make it ideal for use in the low-and-middle-income countries.


Assuntos
Radioterapia/métodos , Neoplasias Encefálicas/cirurgia , Simulação por Computador , Ouro , Humanos , Nanopartículas Metálicas , Modelos Biológicos , Método de Monte Carlo , Radiografia/métodos , Radiometria/métodos , Radiocirurgia/métodos , Dosagem Radioterapêutica , Terapia por Raios X/métodos , Raios X
16.
Crit Rev Oncog ; 23(1-2): 93-112, 2018.
Artigo em Inglês | MEDLINE | ID: mdl-29953369

RESUMO

Although modern radiation therapy delivers a localized distribution of ionizing energy that can be used to cure primary cancers for many patients, the inevitable radiation exposure to non-targeted normal tissue leads to a risk of a radiation-related new cancer. Modern therapies often produce a complex spectrum of secondary particles, both charged and uncharged, that must be considered both in their physical radiation transport throughout the patient and their potential to induce biological damage, which depends on the microscopic energy deposition from the cascade of primary, secondary, and downstream particles. This work summarizes the experimental data for relative biological effectiveness for particles associated with modern radiotherapy in light of their capacity to induce secondary malignancies in patients. A distinction is highlighted between the radiobiological experimental data and the coarser metrics used frequently in radiation protection. For critical assessment of the risks of secondary malignancies for patients undergoing radiation therapy, a detailed description of primary and secondary radiation fields is needed, though not routinely considered for individual patient treatments. Furthermore, not only the particle type, but also the microscopic dose and track structure, must be considered, which points to a demand for detailed physics models and high-performance computing strategies to model the risks.


Assuntos
Segunda Neoplasia Primária/etiologia , Medicina de Precisão , Radioterapia/efeitos adversos , Animais , Transformação Celular Neoplásica/efeitos da radiação , Humanos , Neoplasias/radioterapia , Segunda Neoplasia Primária/diagnóstico , Segunda Neoplasia Primária/epidemiologia , Medicina de Precisão/efeitos adversos , Medicina de Precisão/métodos , Radiação Ionizante , Radioterapia/métodos , Dosagem Radioterapêutica , Medição de Risco
17.
Int J Radiat Oncol Biol Phys ; 100(1): 226-234, 2018 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-29254775

RESUMO

PURPOSE: To develop and implement a practical repainting method for efficient interplay effect mitigation in proton pencil beam scanning (PBS). METHODS AND MATERIALS: A new flexible repainting scheme with spot-adapted numbers of repainting evenly spread out over the whole breathing cycle (assumed to be 4 seconds) was developed. Twelve fields from 5 thoracic and upper abdominal PBS plans were delivered 3 times using the new repainting scheme to an ion chamber array on a motion stage. One time was static and 2 used 4-second, 3-cm peak-to-peak sinusoidal motion with delivery started at maximum inhalation and maximum exhalation. For comparison, all dose measurements were repeated with no repainting and with 8 repaintings. For each motion experiment, the 3%/3-mm gamma pass rate was calculated using the motion-convolved static dose as the reference. Simulations were first validated with the experiments and then used to extend the study to 0- to 5-cm motion magnitude, 2- to 6-second motion periods, patient-measured liver tumor motion, and 1- to 6-fraction treatments. The effect of the proposed method was evaluated for the 5 clinical cases using 4-dimensional (4D) dose reconstruction in the planning 4D computed tomography scan. The target homogeneity index, HI = (D2 - D98)/Dmean, of a single-fraction delivery is reported, where D2 and D98 is the dose delivered to 2% and 98% of the target, respectively, and Dmean is the mean dose. RESULTS: The gamma pass rates were 59.6% ± 9.7% with no repainting, 76.5% ± 10.8% with 8 repaintings, and 92.4% ± 3.8% with the new repainting scheme. Simulations reproduced the experimental gamma pass rates with a 1.3% root-mean-square error and demonstrated largely improved gamma pass rates with the new repainting scheme for all investigated motion scenarios. One- and two-fraction deliveries with the new repainting scheme had gamma pass rates similar to those of 3-4 and 6-fraction deliveries with 8 repaintings. The mean HI for the 5 clinical cases was 14.2% with no repainting, 13.7% with 8 repaintings, 12.0% with the new repainting scheme, and 11.6% for the 4D dose without interplay effects. CONCLUSIONS: A novel repainting strategy for efficient interplay effect mitigation was proposed, implemented, and shown to outperform conventional repainting in experiments, simulations, and dose reconstructions. This strategy could allow for safe and more optimal clinical delivery of thoracic and abdominal proton PBS and better facilitate hypofractionated and stereotactic treatments.


Assuntos
Neoplasias/radioterapia , Movimentos dos Órgãos , Terapia com Prótons/métodos , Respiração , Neoplasias Brônquicas/radioterapia , Carcinoma Pulmonar de Células não Pequenas/radioterapia , Carcinoma de Células Renais/radioterapia , Expiração , Tomografia Computadorizada Quadridimensional/métodos , Humanos , Inalação , Neoplasias Renais/radioterapia , Neoplasias Hepáticas/radioterapia , Neoplasias Pulmonares/radioterapia , Neoplasias Pancreáticas/radioterapia , Planejamento da Radioterapia Assistida por Computador/métodos , Software , Fatores de Tempo
18.
Int J Radiat Oncol Biol Phys ; 99(3): 680-688, 2017 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-29280463

RESUMO

PURPOSE/OBJECTIVES: Radiation-induced erectile-dysfunction (RiED) is one of the most common side effects of radiation therapy (RT) and significantly reduces the quality of life (QoL) of cancer patients. Approximately 50% of prostate cancer patients experience RiED within 3 to 5 years after completion of RT. A series of vascular, muscular, and neurogenic injuries after prostate RT lead to RiED; however, the precise role of RT-induced neurogenic injury in RiED has not been fully established. The cavernous nerves (CN) are postganglionic parasympathetic nerves located beside the prostate gland that assist in penile erection. This study was designed to investigate the role of CN injury, tissue damage, and altered signaling pathways in an RiED rat model. METHODS AND MATERIALS: Male rats were exposed to a single dose of 25 Gy prostate-confined RT. Erectile function was evaluated by intracavernous pressure (ICP) measurements conducted both 9 and 14 weeks after RT. Neuronal injury was evaluated in the CN using quantitative polymerase chain reaction, conduction studies, transmission electron microscopy, and immunoblotting. Masson trichrome staining was performed to elucidate fibrosis level in penile tissues. RESULTS: There were significant alterations in the ICP (P<.0001) of RT rats versus non-RT rats. TEM analysis showed decreased myelination, increased microvascular damage, and progressive axonal atrophy of the CN fibers after RT. Electrophysiologic analysis showed significant impairment of the CN conduction velocity after RT. RT also significantly increased RhoA/Rho-associated protein kinase 1 (ROCK1) mRNA and protein expression. In addition, penile tissue showed increased apoptosis and fibrosis 14 weeks after RT. CONCLUSIONS: RT-induced CN injury may contribute to RiED; this is therefore a rationale for developing novel therapeutic strategies to mitigate CN and tissue damage. Moreover, further investigation of the RhoA/ROCK pathway's role in mitigating RiED is necessary.


Assuntos
Disfunção Erétil/etiologia , Fibras Parassimpáticas Pós-Ganglionares/efeitos da radiação , Próstata/inervação , Lesões Experimentais por Radiação/complicações , Animais , Modelos Animais de Doenças , Disfunção Erétil/fisiopatologia , Masculino , Condução Nervosa/fisiologia , Fibras Parassimpáticas Pós-Ganglionares/fisiopatologia , Ereção Peniana/fisiologia , Ereção Peniana/efeitos da radiação , Pênis/inervação , Pênis/patologia , Pênis/efeitos da radiação , Lesões Experimentais por Radiação/fisiopatologia , Distribuição Aleatória , Ratos , Ratos Sprague-Dawley , Coloração e Rotulagem
19.
J Pharm Pharm Sci ; 9(1): 32-9, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-16849006

RESUMO

PURPOSE: To evaluate the permeability enhancing effects of octylglucoside (OG) for molecules with poor absorption such as insulin by in vitro cell models. METHODS: Transepithelial electrical resistance (TEER) was monitored to ensure monolayer integrity. Permeability was ascertained using paracellular markers. Markers and insulin were dissolved in Hanks balanced salt solution and placed on the apical side of the cells in Transwell(c) plates and allowed to diffuse under sink conditions. RESULTS: The effect of OG on the permeability of molecules across both monolayers was concentration and time dependent. Enhanced transport of the three molecules was observed across both monolayers treated with OG as compared to untreated monolayers. The effects of OG were reversible at low concentrations but there was permanent damage to cells at higher concentrations. Absorption enhancement was greater across T-84 monolayers compared to Caco-2 monolayers. CONCLUSIONS: The results indicate OG has potential as a permeability enhancer for poorly absorbed drugs with no significant damage to monolayers at low concentrations. Immediate attenuation in TEER upon exposure to OG indicates that permeability enhancing effects were likely to be associated with modulation of tight junctions suggesting the involvement of paracellular transport.


Assuntos
Permeabilidade da Membrana Celular/efeitos dos fármacos , Células Epiteliais/efeitos dos fármacos , Glucosídeos/farmacologia , Glicosídeos/farmacologia , Insulina/farmacocinética , Absorção , Células CACO-2 , Interações Medicamentosas , Células Epiteliais/metabolismo , Humanos , Células Tumorais Cultivadas
20.
Phys Med Biol ; 61(7): 2633-45, 2016 Apr 07.
Artigo em Inglês | MEDLINE | ID: mdl-26961764

RESUMO

Monte Carlo (MC) methods are acknowledged as the most accurate technique to calculate dose distributions. However, due its lengthy calculation times, they are difficult to utilize in the clinic or for large retrospective studies. Track-repeating algorithms, based on MC-generated particle track data in water, accelerate dose calculations substantially, while essentially preserving the accuracy of MC. In this study, we present the validation of an efficient dose calculation algorithm for intensity modulated proton therapy, the fast dose calculator (FDC), based on a track-repeating technique. We validated the FDC algorithm for 23 patients, which included 7 brain, 6 head-and-neck, 5 lung, 1 spine, 1 pelvis and 3 prostate cases. For validation, we compared FDC-generated dose distributions with those from a full-fledged Monte Carlo based on GEANT4 (G4). We compared dose-volume-histograms, 3D-gamma-indices and analyzed a series of dosimetric indices. More than 99% of the voxels in the voxelized phantoms describing the patients have a gamma-index smaller than unity for the 2%/2 mm criteria. In addition the difference relative to the prescribed dose between the dosimetric indices calculated with FDC and G4 is less than 1%. FDC reduces the calculation times from 5 ms per proton to around 5 µs.


Assuntos
Algoritmos , Neoplasias/radioterapia , Terapia com Prótons/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Feminino , Humanos , Masculino