Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 101
Filtrar
1.
Clin Oral Investig ; 28(6): 313, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748295

RESUMO

OBJECTIVES: This randomized clinical trial focused on patients with thin peri-implant soft-tissue height (STH) (≤ 2.5 mm) and investigated the impact of an allogenic collagen scaffold (aCS) on supracrestal tissue height and marginal bone loss (MBL). MATERIAL & METHODS: Forty patients received bone level implants and were randomly assigned to the test group with simultaneous tissue thickening with aCS or the control group. After three months, prosthetic restoration occurred. STH measurements were taken at baseline (T0) and reopening surgery (TR), with MBL assessed at 12 months (T1). Descriptive statistics were calculated for continuous variables, and counts for categorical variables (significance level, p = 0.05). RESULTS: At T1, 37 patients were available. At T0, control and test groups had mean STH values of 2.3 ± 0.3 mm and 2.1 ± 0.4 mm. TR revealed mean STH values of 2.3 ± 0.2 mm (control) and 2.6 ± 0.7 mm (test), with a significant tissue thickening of 0.5 ± 0.6 mm in the test group (p < 0.03). At T1, control and test groups showed MBL mean values of 1.1 ± 0.8 mm and 1.0 ± 0.6 mm, with a moderate but significant correlation with STH thickening (-0.34), implant position (0.43), history of periodontitis (0.39), and smoking status (0.27). CONCLUSION: The use of an aCS protocol resulted in soft tissue thickening but did not reach a threshold to reliably reduce MBL compared to the control group within the study's limitations. CLINICAL RELEVANCE: Peri-implant STH is crucial for maintaining peri-implant marginal bone stability. Marginal bone stability represents a crucial factor in prevention of peri-implantitis development. German register of clinical trial registration number DRKS00033290.


Assuntos
Perda do Osso Alveolar , Colágeno , Alicerces Teciduais , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Perda do Osso Alveolar/prevenção & controle , Resultado do Tratamento , Implantação Dentária Endóssea/métodos , Adulto , Idoso , Implantes Dentários
2.
Clin Oral Implants Res ; 34(7): 719-726, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37248956

RESUMO

AIM: To assess in vitro the workflow for alveolar ridge augmentation with customised 3D printed block grafts and simultaneous computer-assisted implant planning and placement. METHODS: Twenty resin mandible models with an edentulous area and horizontal ridge defect in the region 34-36 were scanned with cone beam computed tomography (CBCT). A block graft for horizontal ridge augmentation in the region 34-36 and an implant in the position 35 were digitally planned. Twenty block grafts were 3D printed out of resin and one template for guided implant placement were stereolithographically produced. The resin block grafts were positioned onto the ridge defects and stabilised with two fixation screws each. Subsequently, one implant was inserted in the position 35 through the corresponding template for guided implant placement. Optical scans of the study models together with the fixated block graft were performed prior to and after implant placement. The scans taken after block grafting were superimposed with the virtual block grafting plan through a best-fit algorithm, and the linear deviation between the planned and the achieved block positions was calculated. The precision of the block fixation was obtained by superimposing the 20 scans taken after grafting and calculating the deviation between the corresponding resin blocks. The superimposition between the scans taken after and prior to implant placement was performed to measure a possible displacement in the block position induced by guided implant placement. The (98-2%)/2 percentile value was determined as a parameter for surface deviation. RESULTS: The mean deviation in the position of the block graft compared to the virtual plan amounted to 0.79 ± 0.13 mm. The mean deviation between the positions of the 20 block grafts measured 0.47 ± 0.2 mm, indicating a clinically acceptable precision. Guided implant placement induced a mean shift of 0.16 ± 0.06 mm in the position of the block graft. CONCLUSIONS: Within the limitations of this in vitro study, it can be concluded that customised block grafts fabricated through CBCT, computer-assisted design and 3D printing allow alveolar ridge augmentation with clinically acceptable predictability and reproducibility. Computer-assisted implant planning and placement can be performed simultaneously with computer-assisted block grafting leading to clinically non-relevant dislocation of block grafts.


Assuntos
Aumento do Rebordo Alveolar , Implantes Dentários , Cirurgia Assistida por Computador , Implantação Dentária Endóssea/métodos , Reprodutibilidade dos Testes , Desenho Assistido por Computador , Tomografia Computadorizada de Feixe Cônico , Cirurgia Assistida por Computador/métodos , Computadores , Aumento do Rebordo Alveolar/métodos , Transplante Ósseo/métodos
3.
J Biomech Eng ; 143(12)2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34318314

RESUMO

Rupture risk assessment of abdominal aortic aneurysms (AAAs) by means of quantifying wall stress is a common biomechanical strategy. However, the clinical translation of this approach has been greatly limited due to the complexity associated with the computational tools required for its implementation. Thus, being able to estimate wall stress using nonbiomechanical markers that can be quantified as a direct outcome of clinical image segmentation would be advantageous in improving the potential implementation of said strategy. In the present work, we investigated the use of geometric indices to predict patient-specific AAA wall stress by means of a novel neural network (NN) modeling approach. We conducted a retrospective review of existing clinical images of two patient groups: 98 asymptomatic and 50 symptomatic AAAs. The images were subject to a protocol consisting of image segmentation, processing, volume meshing, finite element modeling, and geometry quantification, from which 53 geometric indices and the spatially averaged wall stress (SAWS) were calculated. SAWS estimated from finite element analysis was considered the gold standard for the predictions. We developed feed-forward NN models composed of an input layer, two dense layers, and an output layer using Keras, a deep learning library in python. The NN models were trained, tested, and validated independently for both AAA groups using all geometric indices, as well as a reduced set of indices resulting from a variable reduction procedure. We compared the performance of the NN models with two standard machine learning algorithms (MARS: multivariate adaptive regression splines and GAM: generalized additive model) and a linear regression model (GLM: generalized linear model). With the reduced sets of indices, the NN-based approach exhibited the highest mean goodness-of-fit (for the symptomatic group 0.71 and for the asymptomatic group 0.79) and lowest mean relative error (17% for both groups). In contrast, MARS yielded a mean goodness-of-fit of 0.59 for the symptomatic group and 0.77 for the asymptomatic group, with relative errors of 17% for the symptomatic group and 22% for the asymptomatic group. GAM had a mean goodness-of-fit of 0.70 for the symptomatic group and 0.80 for the asymptomatic group, with relative errors of 16% for the symptomatic group and 20% for the asymptomatic group. GLM did not perform as well as the other algorithms, with a mean goodness-of-fit of 0.53 for the symptomatic group and 0.70 for the asymptomatic group, with relative errors of 19% for the symptomatic group and 23% for the asymptomatic group. Nevertheless, the NN models required a reduced set of 15 and 13 geometric indices to predict SAWS for the symptomatic and asymptomatic AAA groups, respectively. This was in contrast to the reduced set of nine and eight geometric indices required to predict SAWS with the MARS and GAM algorithms for each AAA group, respectively. The use of NN modeling represents a promising alternative methodology for the estimation of AAA wall stress using geometric indices as surrogates, in lieu of finite element modeling. The performance metrics of NN models are expected to improve with significantly larger group sizes, given the suitability of NN modeling for "big data" applications.


Assuntos
Aneurisma da Aorta Abdominal , Ruptura Aórtica , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/complicações , Análise de Elementos Finitos , Humanos , Modelos Cardiovasculares , Redes Neurais de Computação , Estudos Retrospectivos , Medição de Risco/métodos , Estresse Mecânico
4.
J Biomech Eng ; 143(3)2021 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-33269788

RESUMO

Myocardial bridging (MB) and coronary atherosclerotic stenosis can impair coronary blood flow and may cause myocardial ischemia or even heart attack. It remains unclear how MB and stenosis are similar or different regarding their impacts on coronary hemodynamics. The purpose of this study was to compare the hemodynamic effects of coronary stenosis and MB using experimental and computational fluid dynamics (CFD) approaches. For CFD modeling, three MB patients with different levels of lumen obstruction, mild, moderate, and severe were selected. Patient-specific left anterior descending (LAD) coronary artery models were reconstructed from biplane angiograms. For each MB patient, the virtually healthy and stenotic models were also simulated for comparison. In addition, an in vitro flow-loop was developed, and the pressure drop was measured for comparison. The CFD simulations results demonstrated that the difference between MB and stenosis increased with increasing MB/stenosis severity and flowrate. Experimental results showed that increasing the MB length (by 140%) only had significant impact on the pressure drop in the severe MB (39% increase at the exercise), but increasing the stenosis length dramatically increased the pressure drop in both moderate and severe stenoses at all flow rates (31% and 93% increase at the exercise, respectively). Both CFD and experimental results confirmed that the MB had a higher maximum and a lower mean pressure drop in comparison with the stenosis, regardless of the degree of lumen obstruction. A better understanding of MB and atherosclerotic stenosis may improve the therapeutic strategies in coronary disease patients and prevent acute coronary syndromes.


Assuntos
Ponte Miocárdica
5.
J Biomech Eng ; 143(5)2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33493273

RESUMO

Biomechanical characterization of abdominal aortic aneurysms (AAAs) has become commonplace in rupture risk assessment studies. However, its translation to the clinic has been greatly limited due to the complexity associated with its tools and their implementation. The unattainability of patient-specific tissue properties leads to the use of generalized population-averaged material models in finite element analyses, which adds a degree of uncertainty to the wall mechanics quantification. In addition, computational fluid dynamics modeling of AAA typically lacks the patient-specific inflow and outflow boundary conditions that should be obtained by nonstandard of care clinical imaging. An alternative approach for analyzing AAA flow and sac volume changes is to conduct in vitro experiments in a controlled laboratory environment. In this study, we designed, built, and characterized quantitatively a benchtop flow loop using a deformable AAA silicone phantom representative of a patient-specific geometry. The impedance modules, which are essential components of the flow loop, were fine-tuned to ensure typical intraluminal pressure conditions within the AAA sac. The phantom was imaged with a magnetic resonance imaging (MRI) scanner to acquire time-resolved images of the moving wall and the velocity field inside the sac. Temporal AAA sac volume changes lead to a corresponding variation in compliance throughout the cardiac cycle. The primary outcome of this work was the design optimization of the impedance elements, the quantitative characterization of the resistive and capacitive attributes of a compliant AAA phantom, and the exemplary use of MRI for flow visualization and quantification of the deformed AAA geometry.


Assuntos
Aneurisma da Aorta Abdominal
6.
J Biomech Eng ; 142(6)2020 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-31633169

RESUMO

In this work, we provide a quantitative assessment of the biomechanical and geometric features that characterize abdominal aortic aneurysm (AAA) models generated from 19 Asian and 19 Caucasian diameter-matched AAA patients. 3D patient-specific finite element models were generated and used to compute peak wall stress (PWS), 99th percentile wall stress (99th WS), and spatially averaged wall stress (AWS) for each AAA. In addition, 51 global geometric indices were calculated, which quantify the wall thickness, shape, and curvature of each AAA. The indices were correlated with 99th WS (the only biomechanical metric that exhibited significant association with geometric indices) using Spearman's correlation and subsequently with multivariate linear regression using backward elimination. For the Asian AAA group, 99th WS was highly correlated (R2 = 0.77) with three geometric indices, namely tortuosity, intraluminal thrombus volume, and area-averaged Gaussian curvature. Similarly, 99th WS in the Caucasian AAA group was highly correlated (R2 = 0.87) with six geometric indices, namely maximum AAA diameter, distal neck diameter, diameter-height ratio, minimum wall thickness variance, mode of the wall thickness variance, and area-averaged Gaussian curvature. Significant differences were found between the two groups for ten geometric indices; however, no differences were found for any of their respective biomechanical attributes. Assuming maximum AAA diameter as the most predictive metric for wall stress was found to be imprecise: 24% and 28% accuracy for the Asian and Caucasian groups, respectively. This investigation reveals that geometric indices other than maximum AAA diameter can serve as predictors of wall stress, and potentially for assessment of aneurysm rupture risk, in the Asian and Caucasian AAA populations.


Assuntos
Aneurisma da Aorta Abdominal , Análise de Elementos Finitos , Fenômenos Biomecânicos , Humanos , Masculino , Pessoa de Meia-Idade , Modelos Cardiovasculares
7.
J Biomech Eng ; 141(9)2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31116359

RESUMO

Trabeculae carneae are irregular structures that cover the endocardial surfaces of both ventricles and account for a significant portion of human ventricular mass. The role of trabeculae carneae in diastolic and systolic functions of the left ventricle (LV) is not well understood. Thus, the objective of this study was to investigate the functional role of trabeculae carneae in the LV. Finite element (FE) analyses of ventricular functions were conducted for three different models of human LV derived from high-resolution magnetic resonance imaging (MRI). The first model comprised trabeculae carneae and papillary muscles, while the second model had papillary muscles and partial trabeculae carneae, and the third model had a smooth endocardial surface. We customized these patient-specific models with myofiber architecture generated with a rule-based algorithm, diastolic material parameters of Fung strain energy function derived from biaxial tests and adjusted with the empirical Klotz relationship, and myocardial contractility constants optimized for average normal ejection fraction (EF) of the human LV. Results showed that the partial trabeculae cutting model had enlarged end-diastolic volume (EDV), reduced wall stiffness, and even increased end-systolic function, indicating that the absence of trabeculae carneae increased the compliance of the LV during diastole, while maintaining systolic function.

8.
Int J Immunogenet ; 45(3): 95-101, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29575597

RESUMO

We reported previously on the widespread occurrence of anti-HLA alloantibodies of the IgA isotype (anti-HLA IgA) in the sera of solid-organ re-transplantation (re-tx) candidates (Arnold et al., ). Specifically focussing on kidney re-tx patients, we now extended our earlier findings by examining the impact of the presence and donor specificity of anti-HLA IgA on graft survival. We observed frequent concurrence of anti-HLA IgA and anti-HLA IgG in 27% of our multicenter collective of 694 kidney re-tx patients. This subgroup displayed significantly reduced graft survival as evidenced by the median time to first dialysis after transplantation (TTD 77 months) compared to patients carrying either anti-HLA IgG or IgA (TTD 102 and 94 months, respectively). In addition, donor specificity of anti-HLA IgA had a significant negative impact on graft survival (TTD 74 months) in our study. Taken together, our data strongly indicate that presence of anti-HLA IgA, in particular in conjunction with anti-HLA-IgG, in sera of kidney re-tx patients is associated with negative transplantation outcome.


Assuntos
Sobrevivência de Enxerto/imunologia , Antígenos HLA/imunologia , Imunoglobulina A/imunologia , Isoanticorpos/imunologia , Transplante de Órgãos , Transplantados , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Alelos , Especificidade de Anticorpos/imunologia , Criança , Pré-Escolar , Feminino , Antígenos HLA/genética , Humanos , Imunoglobulina A/sangue , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Isoanticorpos/sangue , Transplante de Rim , Masculino , Pessoa de Meia-Idade , Transplante de Órgãos/efeitos adversos , Prognóstico , Retratamento , Adulto Jovem
9.
Ann Vasc Surg ; 44: 190-196, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28546046

RESUMO

BACKGROUND: Currently, the risk of abdominal aortic aneurysm (AAA) rupture is determined using the maximum diameter (Dmax) of the aorta. We sought in this study to identify a set of computed tomography (CT)-based geometric parameters that would better predict the risk of rupture than Dmax. METHODS: We obtained CT scans from 180 patients (90 ruptured AAA and 90 elective AAA repair) and then used automated software to calculate 1- , 2- , and 3-dimensional geometric parameters for each AAA. Linear regression was used to identify univariate correlates of membership in the rupture group. We then used stepwise backward elimination to generate a logistic regression model for prediction of rupture. RESULTS: Linear regression identified 40 correlates of rupture. Following stepwise backward elimination, we developed a multivariate logistic regression model containing 15 geometric parameters, including Dmax. This model was compared with a model containing Dmax alone. The multivariate model correctly classified 98% of all cases, whereas the Dmax-only model correctly classified 72% of cases. Receiver operating characteristic analysis showed that the multivariate model had an area under the curve of 0.995, as compared with 0.770 for the Dmax-only model. This difference was highly significant (P < 0.0001). CONCLUSIONS: This study demonstrates that a multivariable model using geometric factors entirely measurable from CT scanning can be a better predictor of AAA rupture than maximum diameter alone.


Assuntos
Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Ruptura Aórtica/etiologia , Aortografia/métodos , Angiografia por Tomografia Computadorizada , Modelos Cardiovasculares , Modelagem Computacional Específica para o Paciente , Área Sob a Curva , Chicago , Humanos , Modelos Lineares , Modelos Logísticos , Análise Multivariada , Pennsylvania , Valor Preditivo dos Testes , Curva ROC , Interpretação de Imagem Radiográfica Assistida por Computador , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Software
10.
J Biomech Eng ; 139(8)2017 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-28538996

RESUMO

The maximum diameter (MD) criterion is the most important factor when predicting risk of rupture of abdominal aortic aneurysms (AAAs). An elevated wall stress has also been linked to a high risk of aneurysm rupture, yet is an uncommon clinical practice to compute AAA wall stress. The purpose of this study is to assess whether other characteristics of the AAA geometry are statistically correlated with wall stress. Using in-house segmentation and meshing algorithms, 30 patient-specific AAA models were generated for finite element analysis (FEA). These models were subsequently used to estimate wall stress and maximum diameter and to evaluate the spatial distributions of wall thickness, cross-sectional diameter, mean curvature, and Gaussian curvature. Data analysis consisted of statistical correlations of the aforementioned geometry metrics with wall stress for the 30 AAA inner and outer wall surfaces. In addition, a linear regression analysis was performed with all the AAA wall surfaces to quantify the relationship of the geometric indices with wall stress. These analyses indicated that while all the geometry metrics have statistically significant correlations with wall stress, the local mean curvature (LMC) exhibits the highest average Pearson's correlation coefficient for both inner and outer wall surfaces. The linear regression analysis revealed coefficients of determination for the outer and inner wall surfaces of 0.712 and 0.516, respectively, with LMC having the largest effect on the linear regression equation with wall stress. This work underscores the importance of evaluating AAA mean wall curvature as a potential surrogate for wall stress.


Assuntos
Aneurisma da Aorta Abdominal/patologia , Estresse Mecânico , Análise de Elementos Finitos , Humanos , Propriedades de Superfície
11.
J Biomech Eng ; 139(1)2017 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-27636678

RESUMO

An abdominal aortic aneurysm (AAA) is a permanent focal dilatation of the abdominal aorta of at least 1.5 times its normal diameter. Although the criterion of maximum diameter is still used in clinical practice to decide on a timely intervention, numerical studies have demonstrated the importance of other geometric factors. However, the major drawback of numerical studies is that they must be validated experimentally before clinical implementation. This work presents a new methodology to verify wall stress predicted from the numerical studies against the experimental testing. To this end, four AAA phantoms were manufactured using vacuum casting. The geometry of each phantom was subject to microcomputed tomography (µCT) scanning at zero and three other intraluminal pressures: 80, 100, and 120 mm Hg. A zero-pressure geometry algorithm was used to calculate the wall stress in the phantom, while the numerical wall stress was calculated with a finite-element analysis (FEA) solver based on the actual zero-pressure geometry subjected to 80, 100, and 120 mm Hg intraluminal pressure loading. Results demonstrate the moderate accuracy of this methodology with small relative differences in the average wall stress (1.14%). Additionally, the contribution of geometric factors to the wall stress distribution was statistically analyzed for the four phantoms. The results showed a significant correlation between wall thickness and mean curvature (MC) with wall stress.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Resistência ao Cisalhamento , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Humanos , Imagens de Fantasmas , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Estresse Mecânico , Tomografia Computadorizada por Raios X/instrumentação
12.
J Biomech Eng ; 138(10)2016 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-27538124

RESUMO

In this work, we present a novel method for the derivation of the unloaded geometry of an abdominal aortic aneurysm (AAA) from a pressurized geometry in turn obtained by 3D reconstruction of computed tomography (CT) images. The approach was experimentally validated with an aneurysm phantom loaded with gauge pressures of 80, 120, and 140 mm Hg. The unloaded phantom geometries estimated from these pressurized states were compared to the actual unloaded phantom geometry, resulting in mean nodal surface distances of up to 3.9% of the maximum aneurysm diameter. An in-silico verification was also performed using a patient-specific AAA mesh, resulting in maximum nodal surface distances of 8 µm after running the algorithm for eight iterations. The methodology was then applied to 12 patient-specific AAA for which their corresponding unloaded geometries were generated in 5-8 iterations. The wall mechanics resulting from finite element analysis of the pressurized (CT image-based) and unloaded geometries were compared to quantify the relative importance of using an unloaded geometry for AAA biomechanics. The pressurized AAA models underestimate peak wall stress (quantified by the first principal stress component) on average by 15% compared to the unloaded AAA models. The validation and application of the method, readily compatible with any finite element solver, underscores the importance of generating the unloaded AAA volume mesh prior to using wall stress as a biomechanical marker for rupture risk assessment.


Assuntos
Aorta Abdominal/diagnóstico por imagem , Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Modelos Cardiovasculares , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Pressão Sanguínea , Simulação por Computador , Humanos , Imageamento Tridimensional/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Resistência ao Cisalhamento
13.
FASEB J ; 27(8): 3017-29, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23616566

RESUMO

Endothelial adhesion is necessary for the hematogenous dissemination of tumor cells. However, the metastatic breast tumor cell MDA-MB-231 does not bind to the endothelium under physiological flow conditions, suggesting alternate mechanisms of adhesion. Since monocytes are highly represented in the tumor microenvironment, and also bind to endothelium during inflammation, we hypothesized that the monocytes assist in the arrest of MDA-MB-231 on the endothelium. Using in vitro models of the dynamic shear environment of the vasculature, we show that TNF-α-activated THP1/primary human monocytes and MDA-MB-231 cells form stable aggregates, and that the monocytes in these aggregates mediate the adhesion of otherwise nonadherent MDA-MB-231 cells to inflamed endothelium under flow (55±2.4 vs. 1.7±0.82 at a shear stress of 0.5 dyn/cm(2), P<0.01). We also show that the hydrodynamic forces determine the size and orientation of aggregates adhered to the endothelium, and strongly favor the attachment of small aggregates with tumor cells downstream of flow (74-86% doublets at 0.5-2 dyn/cm(2), P<0.01). The 5-fold up-regulation of ICAM-1 on TNF-α-activated MDA-MB-231 cells through the Nf-κB pathway was found to be critical in MDA-MB-231-monocyte aggregation and endothelial adhesion. Our results demonstrate that, under inflammatory conditions, monocytes may serve to disseminate tumor cells through circulation, and the tumor-monocyte-endothelial axis may represent a new therapeutic target to reduce cancer metastasis.


Assuntos
Endotélio Vascular/metabolismo , Molécula 1 de Adesão Intercelular/metabolismo , Monócitos/metabolismo , NF-kappa B/metabolismo , Neoplasias da Mama/genética , Neoplasias da Mama/metabolismo , Neoplasias da Mama/patologia , Adesão Celular , Agregação Celular/efeitos dos fármacos , Linhagem Celular Tumoral , Células Cultivadas , Simulação por Computador , Endotélio Vascular/patologia , Humanos , Molécula 1 de Adesão Intercelular/genética , Cinética , NF-kappa B/genética , Metástase Neoplásica , Transdução de Sinais/efeitos dos fármacos , Estresse Mecânico , Fator de Necrose Tumoral alfa/farmacologia , Regulação para Cima/efeitos dos fármacos
14.
J Biomech Eng ; 136(12): 121010, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25322073

RESUMO

To quantify the transport and adhesion of drug particles in a complex vascular environment, computational fluid particle dynamics (CFPD) simulations of blood flow and drug particulate were conducted in three different geometries representing the human lung vasculature for steady and pulsatile flow conditions. A fully developed flow profile was assumed as the inlet velocity, and a lumped mathematical model was used for the calculation of the outlet pressure boundary condition. A receptor-ligand model was used to simulate the particle binding probability. The results indicate that bigger particles have lower deposition fraction due to less chance of successful binding. Realistic unsteady flow significantly accelerates the binding activity over a wide range of particle sizes and also improves the particle deposition fraction in bifurcation regions when comparing with steady flow condition. Furthermore, surface imperfections and geometrical complexity coupled with the pulsatility effect can enhance fluid mixing and accordingly particle binding efficiency. The particle binding density at bifurcation regions increases with generation order and drug carriers are washed away faster in steady flow. Thus, when studying drug delivery mechanism in vitro and in vivo, it is important to take into account blood flow pulsatility in realistic geometry. Moreover, tissues close to bifurcations are more susceptible to deterioration due to higher uptake.


Assuntos
Hidrodinâmica , Pulmão/irrigação sanguínea , Modelos Biológicos , Artéria Pulmonar/metabolismo , Adulto , Transporte Biológico , Humanos , Tamanho da Partícula , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiologia , Fluxo Pulsátil , Tomografia Computadorizada por Raios X
15.
J Biomech Eng ; 136(1): 014502, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24190650

RESUMO

The goal of this work is to develop a framework for manufacturing nonuniform wall thickness replicas of abdominal aortic aneurysms (AAAs). The methodology was based on the use of computed tomography (CT) images for virtual modeling, additive manufacturing for the initial physical replica, and a vacuum casting process and range of polyurethane resins for the final rubberlike phantom. The average wall thickness of the resulting AAA phantom was compared with the average thickness of the corresponding patient-specific virtual model, obtaining an average dimensional mismatch of 180 µm (11.14%). The material characterization of the artery was determined from uniaxial tensile tests as various combinations of polyurethane resins were chosen due to their similarity with ex vivo AAA mechanical behavior in the physiological stress configuration. The proposed methodology yields AAA phantoms with nonuniform wall thickness using a fast and low-cost process. These replicas may be used in benchtop experiments to validate deformations obtained with numerical simulations using finite element analysis, or to validate optical methods developed to image ex vivo arterial deformations during pressure-inflation testing.


Assuntos
Aneurisma da Aorta Abdominal/diagnóstico por imagem , Aneurisma da Aorta Abdominal/fisiopatologia , Simulação por Computador , Modelos Cardiovasculares , Aneurisma da Aorta Abdominal/patologia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos , Imageamento Tridimensional , Modelos Anatômicos , Imagens de Fantasmas , Estresse Fisiológico , Tomografia Computadorizada por Raios X
16.
J Biomech Eng ; 136(7)2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24718322

RESUMO

Skin wounds and burns compromise the body's natural barrier to bacteria and other pathogens. While many forms of wound dressings are available, polymeric films are advantageous for various reasons, ranging from the ease of application to durability. One common drawback of using polymeric films for a wound bandage is that the films tend to adhere to common inanimate objects. Patients spend hours in contact with soft and hard materials pressed against their skin, which, if the skin was dressed with a polymeric film, would inflict further wound damage upon body movement. In this work, we present a novel technique that allowed for measuring polymeric tackiness, after a long incubation period, with materials regularly encountered in a hospital or home setting, and soft fabrics. The polymers were exposed to an environment intended to simulate daily conditions and the technique is designed to perform multiple experiments simultaneously with ease. Four commercially available polymers (new-skin, no-sting skin-prep, skin shield, and Silesse) were tested as proof-of-concept to gather preliminary data for an overall assessment of wound treatment efficacy, resulting in the estimation of pull-off stress of the polymers from a specimen of porcine skin. Silesse did not reveal a measurable tackiness, no-sting skin-prep had the highest mean tackiness (13.8 kPa), while the mean tackiness between new-skin and skin shield was approximately equal (9.8 kPa vs. 10.1 kPa, respectively), p = 0.05. Future work on polymeric fluids for wound dressing applications should include tensile stress and dynamic viscosity estimations.


Assuntos
Bandagens , Teste de Materiais/métodos , Polímeros , Estresse Mecânico , Cicatrização , Adesividade , Animais , Teste de Materiais/instrumentação , Pele , Suínos
17.
J Biomech Eng ; 136(3): 031001, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24316984

RESUMO

The pathology of the human abdominal aortic aneurysm (AAA) and its relationship to the later complication of intraluminal thrombus (ILT) formation remains unclear. The hemodynamics in the diseased abdominal aorta are hypothesized to be a key contributor to the formation and growth of ILT. The objective of this investigation is to establish a reliable 3D flow visualization method with corresponding validation tests with high confidence in order to provide insight into the basic hemodynamic features for a better understanding of hemodynamics in AAA pathology and seek potential treatment for AAA diseases. A stereoscopic particle image velocity (PIV) experiment was conducted using transparent patient-specific experimental AAA models (with and without ILT) at three axial planes. Results show that before ILT formation, a 3D vortex was generated in the AAA phantom. This geometry-related vortex was not observed after the formation of ILT, indicating its possible role in the subsequent appearance of ILT in this patient. It may indicate that a longer residence time of recirculated blood flow in the aortic lumen due to this vortex caused sufficient shear-induced platelet activation to develop ILT and maintain uniform flow conditions. Additionally, two computational fluid dynamics (CFD) modeling codes (Fluent and an in-house cardiovascular CFD code) were compared with the two-dimensional, three-component velocity stereoscopic PIV data. Results showed that correlation coefficients of the out-of-plane velocity data between PIV and both CFD methods are greater than 0.85, demonstrating good quantitative agreement. The stereoscopic PIV study can be utilized as test case templates for ongoing efforts in cardiovascular CFD solver development. Likewise, it is envisaged that the patient-specific data may provide a benchmark for further studying hemodynamics of actual AAA, ILT, and their convolution effects under physiological conditions for clinical applications.


Assuntos
Aorta Abdominal/fisiopatologia , Aneurisma da Aorta Abdominal/fisiopatologia , Imageamento Tridimensional/métodos , Modelos Cardiovasculares , Reologia/métodos , Trombose/fisiopatologia , Aorta Abdominal/patologia , Aneurisma da Aorta Abdominal/complicações , Aneurisma da Aorta Abdominal/patologia , Velocidade do Fluxo Sanguíneo , Pressão Sanguínea , Simulação por Computador , Humanos , Trombose/etiologia , Trombose/patologia
18.
Clin Oral Investig ; 18(2): 579-87, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-23636610

RESUMO

OBJECTIVES: This study aims to evaluate the effect of a minimally invasive mesial-occlusal-distal (mod) preparation on the marginal adaptation of ceramic and composite inlays with the aim of saving sound dental substance. MATERIALS AND METHODS: Class II mod cavities were prepared in 50 extracted human molars and randomly allocated to five groups (n = 10). In all groups, the mesial-proximal box margins were located in the dentin, 1 mm below the cementoenamel junction (CEJ), while the distal box margins were 1 mm above the CEJ. In groups A and B, conventional standard preparations with a divergent angle of α = 6° were prepared. In groups C, D, and E, minimally invasive standard preparations with a convergent angle of α = 10° were prepared. In groups A and D, composite inlays and, in groups B and C, ceramic inlays were fabricated (chairside economical restoration of esthetic ceramics (CEREC)) and adhesively inserted. In group E, a direct composite filling using the incremental technique was placed. Replicas were taken before and after thermomechanical loading (1,200,000 cycles, 50/5 °C, max. load 49 N). Marginal integrity (tooth-luting composite, luting composite-inlay) was evaluated by scanning electron microscopy (× 200). The percentage of continuous margins in the different locations was compared between and within groups before and after cycling, using ANOVA and Scheffé post hoc test. RESULTS: After the thermomechanical loading, no significant differences were observed between the different groups with respect to the interface of luting composite-inlay. At the interface of tooth-luting composite for preparations involving the dentin, groups A and B behaved significantly better compared to the control group E, which in turn were not different to groups C and D. CONCLUSION: Composite and ceramic inlays inserted in minimally invasive prepared mod cavities result in margins not different from those of inlays placed in conventional mod preparations. Direct composite filling margins, however, were inferior to those attained by conventional indirect restorations. CLINICAL RELEVANCE: Minimally invasive preparations for mod inlays with undercuts show marginal adaptation equal to that of conventional inlay preparation design.


Assuntos
Cerâmica , Resinas Compostas , Cárie Dentária/patologia , Cimentos Dentários , Humanos , Microscopia Eletrônica de Varredura
19.
J Esthet Restor Dent ; 26(3): 191-9, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-24341747

RESUMO

OBJECTIVE: The use of periodontal probes harbors the risk of measurement errors. The aim of this study was to investigate the accuracy of the digital determination of gingival recession and papilla height on virtual jaw models, given the hypothesis that they show lower intrarater and interrater variability than conventional linear measurements taken clinically or on cast models. MATERIALS AND METHODS: Gingival recessions and papilla heights were measured at 30 sites by five examiners using the following methods: (A) direct measurements using a periodontal probe intraorally or (B) on cast models using a caliper, (C) digital measurements on virtual models obtained by optical scans taken intraorally, or (D) made of cast models using the same software. Measurements were repeated after 1 week and intraclass, intrarater, and interrater correlations of the measurements using the four different methods were analyzed. RESULTS: The greatest disagreement between the 1st and 2nd measurement was identified for method A. Recessions were less reliably measured than papillae. The best agreement between methods was found in the digital ones (C and D). Regarding papilla height, increased values were obtained when method D was applied as compared with both clinical evaluations. For gingival recession, method A measured the highest values. CONCLUSION: In the present study, the use of digital technologies by intraoral scanning or scanning of cast models improved the reproducibility and lowered the variance of measurements within one individual and between different investigators. CLINICAL SIGNIFICANCE: Providing a more reliable and examiner-independent technique for measurements of the soft tissue architecture could improve data quality in periodontal research and in the analysis of different clinical treatment modalities.


Assuntos
Gengiva/anatomia & histologia , Retração Gengival/patologia , Periodontia/instrumentação , Desenho Assistido por Computador/estatística & dados numéricos , Desenho de Equipamento , Humanos , Processamento de Imagem Assistida por Computador/estatística & dados numéricos , Modelos Dentários , Variações Dependentes do Observador , Imagem Óptica/estatística & dados numéricos , Reprodutibilidade dos Testes , Tecnologia Odontológica/estatística & dados numéricos , Colo do Dente/anatomia & histologia , Coroa do Dente/anatomia & histologia , Interface Usuário-Computador
20.
Int J Comput Dent ; 17(1): 53-64, 2014.
Artigo em Inglês, Alemão | MEDLINE | ID: mdl-24791465

RESUMO

Intraoral and extraoral scanning systems are continuously improving in terms of operational reliability and image quality. This creates new application options for the standard use of these systems in dental practice. Three-dimensional scans for volumetric and differential analysis of jaw position over time can be generated by superimposing partial or full-arch scans recorded at different time points. These analyses can be performed in a wide range of dental applications to compare and follow treatments or diagnoses over time. In this article, we will describe the indications and applications for OraCheck, a new software application that will be available to Cerec users in Spring 2014.


Assuntos
Desenho Assistido por Computador , Técnica de Moldagem Odontológica , Imageamento Tridimensional/métodos , Software , Apresentação de Dados , Técnica de Moldagem Odontológica/normas , Seguimentos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Processamento de Imagem Assistida por Computador/normas , Imageamento Tridimensional/normas , Registro da Relação Maxilomandibular/métodos , Controle de Qualidade , Interface Usuário-Computador
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA