RESUMO
BACKGROUND: The clinical efficacy and safety of alcohol septal ablation (ASA) for obstructive hypertrophic cardiomyopathy (HCM) have been well-established; however, less is known about outcomes in patients undergoing preemptive ASA before transcatheter mitral valve replacement (TMVR). AIMS: The goal of this study is to characterize the procedural characteristics and examine the clinical outcomes of ASA in both HCM and pre-TMVR. METHODS: This retrospective study compared procedural characteristics and outcomes in patient who underwent ASA for HCM and TMVR. RESULTS: In total, 137 patients were included, 86 in the HCM group and 51 in the TMVR group. The intraventricular septal thickness (mean 1.8 vs. 1.2 cm; p < 0.0001) and the pre-ASA LVOT gradient (73.6 vs. 33.8 mmHg; p ≤ 0.001) were higher in the HCM group vs the TMVR group. The mean volume of ethanol injected was higher (mean 2.4 vs. 1.7 cc; p < 0.0001). The average neo-left ventricular outflow tract area increased significantly after ASA in the patients undergoing TMVR (99.2 ± 83.37 mm2 vs. 196.5 ± 114.55 mm2; p = <0.0001). The HCM group had a greater reduction in the LVOT gradient after ASA vs the TMVR group (49.3 vs. 18 mmHg; p = 0.0040). The primary composite endpoint was higher in the TMVR group versus the HCM group (50.9% vs. 25.6%; p = 0.0404) and had a higher incidence of new permanent pacemaker (PPM) (25.5% vs. 18.6%; p = 0.3402). The TMVR group had a higher rate of all-cause mortality (9.8% vs. 1.2%; p = 0.0268). CONCLUSIONS: Preemptive ASA before TMVR was performed in patients with higher degree of clinical comorbidities, and correspondingly is associated with worse short-term clinical outcomes in comparison to ASA for HCM patients. ASA before TMVR enabled percutaneous mitral interventions in a small but significant minority of patients that would have otherwise been excluded. The degree of LVOT and neoLVOT area increase is significant and predictable.
Assuntos
Técnicas de Ablação , Cateterismo Cardíaco , Cardiomiopatia Hipertrófica , Etanol , Implante de Prótese de Valva Cardíaca , Valva Mitral , Humanos , Estudos Retrospectivos , Masculino , Etanol/administração & dosagem , Etanol/efeitos adversos , Cardiomiopatia Hipertrófica/diagnóstico por imagem , Cardiomiopatia Hipertrófica/mortalidade , Cardiomiopatia Hipertrófica/terapia , Cardiomiopatia Hipertrófica/cirurgia , Cardiomiopatia Hipertrófica/fisiopatologia , Feminino , Resultado do Tratamento , Técnicas de Ablação/efeitos adversos , Técnicas de Ablação/mortalidade , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/mortalidade , Cateterismo Cardíaco/instrumentação , Pessoa de Meia-Idade , Fatores de Risco , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Fatores de Tempo , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Recuperação de Função Fisiológica , Idoso de 80 Anos ou mais , Septos Cardíacos/diagnóstico por imagem , Septos Cardíacos/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/mortalidadeRESUMO
Left ventricular pseudoaneurysm (PSA) after surgical aortic valve replacement (AVR) is a known but uncommon complication. It is associated with risks such as thromboembolism and life-threatening rupture. Surgical repair has traditionally been utilized in low-risk patients but transcatheter closure has become a promising therapeutic option. This case report describes the utility of multimodality imaging in pre-, intra-, and post-procedural evaluation of transcatheter PSA closure and is among the first to demonstrate the utility of 3D print model.
Assuntos
Falso Aneurisma , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/cirurgia , Cateterismo Cardíaco/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Aórtica/cirurgia , Substituição da Valva Aórtica Transcateter/métodos , Imagem Multimodal , Resultado do TratamentoRESUMO
BACKGROUND: HIV-infected persons develop coronary artery disease (CAD) more commonly and earlier than uninfected persons; however, the role of non-invasive testing to stratify CAD risk in HIV is not well defined. METHODS AND RESULTS: Patients were selected from a single-center electronic cohort of HIV-infected patients and uninfected controls matched 1:2 on age, sex, race, and type of cardiovascular testing performed. Patients with abnormal echocardiographic or nuclear stress testing who subsequently underwent coronary angiography were included. Logistic regressions were used to assess differences by HIV serostatus in two co-primary endpoints: (1) severe CAD (≥70% stenosis of at least one coronary artery) and (2) performance of percutaneous coronary intervention (PCI). HIV-infected patients (N = 189) were significantly more likely to undergo PCI following abnormal stress test when compared with uninfected persons (N = 319) after adjustment for demographics, CAD risk factors, previous coronary intervention, and stress test type (OR 1.85, 95% CI 1.12-3.04, P = 0.003). No associations between HIV serostatus and CAD were statistically significant, although there was a non-significant trend toward greater CAD for HIV-infected patients. CONCLUSIONS: HIV-infected patients with abnormal cardiovascular stress testing who underwent subsequent coronary angiography did not have a significantly greater CAD burden than uninfected controls, but were significantly more likely to receive PCI.
Assuntos
Doença da Artéria Coronariana/epidemiologia , Infecções por HIV/complicações , Idoso , Estudos de Casos e Controles , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Teste de Esforço , Feminino , Infecções por HIV/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea , Índice de Gravidade de DoençaRESUMO
BACKGROUND: Percutaneous closure of aortic and ventricular pseudoaneurysms (PSA) has only been reported on a case report and series basis. In previous case reports, percutaneous closure has been performed successfully in patients of prohibitive surgical risk. This case series aims to show feasibility of percutaneous closure of aortic and ventricular pseudoaneurysm secondary to perivalvular leak (PVL) in a small patient population and the utility of multimodality imaging as an integral tool in procedural planning. This is the largest complex case series to date describing the feasibility and success rate of complex PSA closure, with a follow-up period of up to 4 years. MATERIAL AND METHODS: We performed institutional review and systemic literature review to identify all paravalvular leak cases with associated pseudoaneurysm formation for which a closure procedure was performed. Ten patients were identified. Pooled analysis for cases from institutional review (n = 10) and systemic literature review (n = 39) was performed. The success rate was 100 %. At 30-days, the mortality was 0 %. CONCLUSION: In paravalvular leak patients with subsequent pseudoaneurysm formation, exhaustive imaging evaluation is required for closure. However, it can be achievable with favorable rates of success.
Assuntos
Falso Aneurisma , Implante de Prótese de Valva Cardíaca , Humanos , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Falso Aneurisma/terapia , Masculino , Feminino , Resultado do Tratamento , Idoso , Pessoa de Meia-Idade , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Aneurisma Cardíaco/diagnóstico por imagem , Aneurisma Cardíaco/etiologia , Aneurisma Cardíaco/terapia , Cateterismo Cardíaco/efeitos adversos , Aneurisma Aórtico/diagnóstico por imagem , Aneurisma Aórtico/cirurgia , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Ecocardiografia Transesofagiana , AdultoRESUMO
Objectives: Mechanical circulatory support is often challenging in patients with cardiogenic shock secondary to valvular heart disease because of challenging device placement, decreased efficacy, the need for a concomitant device for left ventricular unloading, or contraindications. Left atrial venoarterial-extracorporeal membranous oxygenation (LAVA-ECMO) is an emerging technique to achieve simultaneous ventricular unloading and circulatory support unaffected by valvular disease. The use of LAVA-ECMO for high-risk transcatheter valvular replacement has not been described. Key Steps: We describe the case of a patient with cardiogenic shock resulting from dual aortic and mitral bioprosthetic degeneration who was treated with LAVA-ECMO-supported dual-transcatheter aortic and mitral valve-in-valve replacement. Potential Pitfalls: Among many precautions worth mentioning, operators should be aware of the care and adjustments of the ECMO circuit required during transcatheter valvular replacement to achieve technical success without complications. The importance of a careful case planning in a multidisciplinary heart team meeting cannot be overemphasized. Take-Home Message: LAVA ECMO enables high-risk valvular replacement in patients in valvular cardiogenic shock.
RESUMO
BACKGROUND: Aortic valve lithotripsy can fragment aortic valve calcium deposits and potentially restore leaflet pliability in animal model and ex-vivo, but clinical data is limited. Transcatheter aortic valve implantation (TAVR) might not be feasible as an urgent procedure in critically ill patients. Balloon valvuloplasty has the major limitation of valve recoil and inducing aortic regurgitation. AIMS: To determine the clinical feasibility of aortic valve lithotripsy-facilitated balloon valvuloplasty in patients with severe aortic stenosis unsuitable for valvular replacement. METHODS: We performed lithotripsy as adjunctive therapy to balloon aortic valvuloplasty in ten consecutive patients, most of whom were deemed unfit for TAVR. Lithotripsy of the aortic valve was performed with simultaneous inflation of one to three peripheral lithotripsy balloons to deliver ultrasound pulses. Rapid pacing was not used during lithotripsy. Aortic valve velocity, gradient, and valve area were measured before and after the procedure by echocardiogram. Transvalvular pressure gradient was recorded intra-procedurally. Periprocedural and ninety-day clinical outcomes were followed. RESULTS: Procedure was technically successful in 9 out of 10 patients and aborted in one patient due to cardiogenic shock. One patient had femoral closure device related complication. There was a statistically significant decrease in valvular gradient and increase in aortic valve area. 9 out of 10 patients recovered from acute episode and were discharged. 6 patients had improvement in NYHA class. 4 patients were subsequently able to receive TAVR. 90-day mortality occurred in 3 patients. There was no stroke or bradyarrhythmia peri-procedurally and no heart failure hospitalization at 90 days. CONCLUSION: Aortic valve lithotripsy-facilitated balloon valvuloplasty has reasonable feasibility, safety and technical reproducibility and acute clinical result. Hemodynamic effect is similar to that of balloon valvuloplasty reported in the literature. Subsequent Prognosis is not altered in critically ill patients.
Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Valvuloplastia com Balão , Estudos de Viabilidade , Litotripsia , Índice de Gravidade de Doença , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/terapia , Estenose da Valva Aórtica/mortalidade , Humanos , Valvuloplastia com Balão/efeitos adversos , Masculino , Feminino , Resultado do Tratamento , Idoso de 80 Anos ou mais , Litotripsia/efeitos adversos , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Valva Aórtica/cirurgia , Fatores de Tempo , Hemodinâmica , Recuperação de Função FisiológicaRESUMO
Early-onset schizophrenia (EOS) shares many biological and clinical features with adult-onset schizophrenia (AOS), but may represent a unique subgroup with greater susceptibility for disease onset and worsened symptomatology and progression, which could potentially derive from exaggerated neurodevelopmental abnormalities. Neurobiological explanations of schizophrenia have emphasized the involvement of deep-brain structures, particularly alterations of the thalamus, which have been linked to core features of the disorder. The aim of this study was to compare thalamic shape abnormalities between EOS and AOS subjects and determine whether unique behavioral profiles related to these differences. It was hypothesized abnormal thalamic shape would be observed in anterior, mediodorsal and pulvinar regions in both schizophrenia groups relative to control subjects, but exacerbated in EOS. Magnetic resonance T1-weighted images were collected from adult individuals with EOS (n = 28), AOS (n = 33), and healthy control subjects (n = 60), as well as collection of clinical and cognitive measures. Large deformation high-dimensional brain mapping was used to obtain three-dimensional surfaces of the thalamus. General linear models were used to compare groups on surface shape features, and Pearson correlations were used to examine relationships between thalamic shape and behavioral measures. Results revealed both EOS and AOS groups demonstrated significant abnormal shape of anterior, lateral and pulvinar thalamic regions relative to CON (all p < 0.007). Relative to AOS, EOS exhibited exacerbated abnormalities in posterior lateral, mediodorsal and lateral geniculate thalamic regions (p = 0.003). Thalamic abnormalities related to worse episodic memory in EOS (p = 0.03) and worse working memory (p = 0.047) and executive functioning (p = 0003) in AOS. Overall, findings suggest thalamic abnormalities are a prominent feature in both early- and late-onset schizophrenia, but exaggerated in EOS and have different brain-behavior profiles for each. The persistence of these abnormalities in adult EOS patients suggests they may represent markers of disrupted neurodevelopment that uniquely relate to the clinical and cognitive aspects of the illness.
RESUMO
The paucity of data regarding the use of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) anatomy due to exclusion from pivotal studies and lack of studies assessing the long-term outcomes and valve performance continue to present a significant challenge as we expand TAVR to patients with BAV anatomy. This article discusses the important anatomic and clinical considerations in the selection and management of patients with BAV with TAVR and reviews the emerging evidence that increasingly suggests this procedure is safe, device success is excellent, and procedural outcomes are improving.
Assuntos
Estenose da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Constrição Patológica , Humanos , Resultado do TratamentoRESUMO
A 78-year-old woman with bioprosthetic mitral valve degeneration at high risk for reoperation was referred for transcatheter mitral valve replacement. We describe the use of a preemptive alcohol septal ablation pre-procedurally to minimize the risk of acute left ventricular outflow tract obstruction given the anticipated need for a bioprosthetic valve fracture. (Level of Difficulty: Advanced.).
RESUMO
The ongoing coronavirus disease 2019 pandemic has resulted in additional challenges for systems designed to perform expeditious primary percutaneous coronary intervention for patients presenting with ST-segment-elevation myocardial infarction. There are 2 important considerations: the guideline-recommended time goals were difficult to achieve for many patients in high-income countries even before the pandemic, and there is a steep increase in mortality when primary percutaneous coronary intervention cannot be delivered in a timely fashion. Although the use of fibrinolytic therapy has progressively decreased over the last several decades in high-income countries, in circumstances when delays in timely delivery of primary percutaneous coronary intervention are expected, a modern fibrinolytic-based pharmacoinvasive strategy may need to be considered. The purpose of this review is to systematically discuss the contemporary role of an evidence-based fibrinolytic reperfusion strategy as part of a pharmacoinvasive approach, in the context of the emerging coronavirus disease 2019 pandemic.