Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
J Cardiovasc Electrophysiol ; 35(3): 418-421, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38213071

RESUMO

INTRODUCTION: Patients with congenital heart disease are at increased risk for requiring cardiac pacing during their lifetime. METHODS: We present the first described case of using two leadless pacing systems manufactured by separate companies implanted within the same patient to provide atrial and ventricular pacing due to complex congenital anatomy. RESULTS: A 27-year-old male with dextrocardia with double outlet right ventricle, subaortic ventricular septal defect, and pulmonary stenosis status-post pulmonary valve replacement complicated by ventricular pacing dependence and subsequent atrial pacing dependence after atriotomy-based atypical flutter ablation developed recurrent mediastinitis and pocket infection with erosion despite prolonged antibiotic treatment. Due to atrial and ventricular pacing dependence, a comprehensive congenital care team concluded the need for lead extraction and replacement of pacemaker via leadless peacemaking device. Laser-lead extraction and temporary atrial pacemaker placement was performed. Afterward, a transesophageal echocardiogram guided implantation of both a Micra AV 2 (Medtronic) leadless pacemaker in the interventricular septum within the right ventricle and an Aveir (Abbott) leadless pacemaker in the superior base of the right atrial appendage was performed with successful pacing. Although there is no communication between these devices, atrial-mechanical ventricular pacing was reliable with good implant thresholds, impedances and sensing from both devices. CONCLUSION: Our case demonstrates the feasibility of using dual leadless pacing modalities to simultaneously pace someone at complex, prohibitive risk for temporary permanent or permanent pacemaker devices.


Assuntos
Dextrocardia , Dupla Via de Saída do Ventrículo Direito , Marca-Passo Artificial , Masculino , Humanos , Adulto , Estimulação Cardíaca Artificial/efeitos adversos , Ventrículos do Coração , Dupla Via de Saída do Ventrículo Direito/etiologia , Resultado do Tratamento , Marca-Passo Artificial/efeitos adversos , Desenho de Equipamento
2.
Artigo em Inglês | MEDLINE | ID: mdl-38695242

RESUMO

INTRODUCTION: Leadless pacemakers (LPM) have established themselves as the important therapeutic modality in management of selected patients with symptomatic bradycardia. To determine real-world utilization and in-hospital outcomes of LPM implantation since its approval by the Food and Drug Administration in 2016. METHODS: For this retrospective cohort study, data were extracted from the National Inpatient Sample database from the years 2016-2020. The outcomes analyzed in our study included implantation trends of LPM over study years, mortality, major complications (defined as pericardial effusion requiring intervention, any vascular complication, or acute kidney injury), length of stay, and cost of hospitalization. Implantation trends of LPM were assessed using linear regression. Using years 2016-2017 as a reference, adjusted outcomes of mortality, major complications, prolonged length of stay (defined as >6 days), and increased hospitalization cost (defined as median cost >34 098$) were analyzed for subsequent years using a multivariable logistic regression model. RESULTS: There was a gradual increased trend of LPM implantation over our study years (3230 devices in years 2016-2017 to 11 815 devices in year 2020, p for trend <.01). The adjusted mortality improved significantly after LPM implantation in subsequent years compared to the reference years 2016-2017 (aOR for the year 2018: 0.61, 95% CI: 0.51-0.73; aOR for the year 2019: 0.49, 95% CI: 0.41-0.59; and aOR for the year 2020: 0.52, 95% CI: 0.44-0.62). No differences in adjusted rates of major complications were demonstrated over the subsequent years. The adjusted cost of hospitalization was higher for the years 2019 (aOR: 1.33, 95% CI: 1.22-1.46) and 2020 (aOR: 1.69, 95% CI: 1.55-1.84). CONCLUSION: The contemporary US practice has shown significantly increased implantation rates of LPM since its approval with reduced rates of inpatient mortality.

3.
Catheter Cardiovasc Interv ; 97(4): 745-754, 2021 03.
Artigo em Inglês | MEDLINE | ID: mdl-33045138

RESUMO

BACKGROUND: During MitraClip implantation sub-valvular correction of trajectory and/or alignment may increase adverse clip or leaflet events. With systematic adjunctive use of fluoroscopy ("Parallax technique"), we aimed to assess parameters that minimize the need for corrective measures and help increase procedural efficiency. METHODS: We retrospectively analyzed 30 patients without (Fl-) and 39 patients utilizing adjunctive fluoroscopy (Fl+) during MitraClip implantation. After establishing trajectory and supra-valvular alignment, the Parallax technique was utilized. Trajectory and alignment are maintained during advancement. RESULTS: All patients had 3 or 4+ MR. There were no differences in baseline demographics. The average number of clips (Fl- vs Fl+) was 1.72 ± 0.8 vs 1.59 ± 0.5, p = .57. For the first clip, the need for sub-valvular alignment (80% vs. 36%, p = .0001), eversion with retraction back to left atrium (23% vs. 10%, p = .001) and the number of grasps (2.3 ± 1.2 vs 1.4 ± 0.9) was reduced. The time from transseptal puncture to first clip deployment (71 ± 21 vs 44 ± 16 min, p = .01) was reduced. Procedural success was achieved in all but one patient in the Fl- group (p = ns). There were no differences noted for in-hospital or 30-day outcomes. CONCLUSIONS: Systematic use of a simple and easy to implement "Parallax technique" was associated with reduced need for sub-valvular manipulation and was associated with improved procedural times. Further larger scale studies are needed to assess the applicability of the technique.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Fluoroscopia , Humanos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
4.
Catheter Cardiovasc Interv ; 96(3): E387-E392, 2020 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-32077578

RESUMO

OBJECTIVES: To propose a novel method for mapping leak location and frequency to a clock-face representation of the left atrial appendage (LAA) ostium. BACKGROUND: LAA occlusion with the Watchman device (WD) is an established therapy to reduce thromboembolic events in patients with atrial fibrillation (AF) and intolerance to long-term oral anticoagulation. Postimplantation leaks are known sequelae, but leak locations and characteristics are poorly described. METHODS: We retrospectively reviewed 101 consecutive WD implants from April 2015 to February 2018. Leak locations from 6-week post-implant transesophageal echocardiograms were mapped to a clock-face representation of the LAA ostium: 12:00 as cranial near the limbus, 3:00 as anterior toward the pulmonary artery, 6:00 as caudal near the mitral annulus, and 9:00 as posterior. Patient demographics, LAA dimensions, and procedural characteristics were also collected. RESULTS: Thirty-four patients had ≥1 leak totaling 45 leaks at 6-week follow-up. Baseline patient demographics showed a mean age 77, CHA2 DS2 VASc 4.69, and 64% of patients with permanent AF. No patient had a detectable leak at the time of implant. At 6 weeks, mean leak size was 2.67 ± 0.89 mm with no leak over 5 mm (largest 4.60 mm). Most leaks occurred along the posterior 6:00-12:00 segment (39/45) and the 6:00-9:00 quadrant (16/45). CONCLUSION: Six-week post-WD implant leaks localize to the posterior LAA ostium. This could result from the elliptical LAA orifice, differential LAA tissue composition, or implantation technique. This study provides a novel method for describing the location of post-implant leaks and serves as the basis for further investigations.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Ecocardiografia Transesofagiana , Falha de Prótese , Dispositivo para Oclusão Septal , Idoso , Idoso de 80 Anos ou mais , Pontos de Referência Anatômicos , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
5.
Catheter Cardiovasc Interv ; 94(6): 829-836, 2019 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-31001927

RESUMO

OBJECTIVES: Review indications and outcomes for transcatheter iatrogenic atrial septal defect (iASD) closure in patients undergoing MitraClip or transseptal (TS) mitral valve-in-valve/ring (ViV/ViR) procedures. BACKGROUND: Mitral valve transcatheter interventions require large-diameter TS sheaths that can result in iASDs that necessitate post-procedure transcatheter closure. Although the presence of iASD has been well-described, indications for closure and outcomes after TS mitral valve interventions have not been reported. METHODS: Patients undergoing MitraClip repair and ViV or ViR transcatheter mitral valve replacement (TMVR) from February 14, 2014, to January 16, 2018, were studied retrospectively in this single center study. RESULTS: Seventeen patients had iASD closure: 11 MitraClip and 6 TMVR (5 ViV, 1 ViR). Indications for iASD closure included large iASD (n = 7), large left-to-right shunt (n = 9), pulmonary hypertension (n = 8), large right-to-left shunt (n = 1), severe RV dysfunction (n = 2), thin/aneurysmal septum (n = 2), and mobile material on pacemaker leads (n = 2). Closures were performed without complications using Amplatzer septal occluders. At 30 days, 94% of subjects (n = 16) were alive with one patient deceased from unknown causes. There were no myocardial infarctions or strokes. At 12 months, follow-up was available for 14 of 17 patients, and 71% of patients (10/14) were alive. One patient died due to cardiac causes, two from noncardiac causes and one for unknown reasons. There was one myocardial infarction, one intraparenchymal hemorrhage, and no ischemic strokes. CONCLUSIONS: The most common reasons for iASD closure after TS MV procedures are: large ASD unlikely to spontaneously close, large left-to-right shunt, and pulmonary hypertension. Patients who required iASD closure had low 30-day mortality but higher one-year mortality potentially reflecting a population with substantial comorbidities.


Assuntos
Septo Interatrial/lesões , Cateterismo Cardíaco/efeitos adversos , Traumatismos Cardíacos/terapia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/cirurgia , Idoso , Idoso de 80 Anos ou mais , Septo Interatrial/diagnóstico por imagem , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Cateteres Cardíacos , Feminino , Traumatismos Cardíacos/diagnóstico por imagem , Traumatismos Cardíacos/etiologia , Traumatismos Cardíacos/mortalidade , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/mortalidade , Humanos , Doença Iatrogênica , Masculino , Valva Mitral/diagnóstico por imagem , Estudos Retrospectivos , Fatores de Risco , Dispositivo para Oclusão Septal , Fatores de Tempo , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 93(5): E311-E317, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30311343

RESUMO

OBJECTIVES: To compare left atrial appendage (LAA) angiography to transesophageal echocardiography (TEE) for assessing usable LAA depth. BACKGROUND: TEE is typically employed for procedural measurement of LAA ostial diameter and depth. Since angiography enhances distal LAA anatomy, we sought to compare angiography to TEE for determining usable LAA depth. METHODS: Seventy five Watchman device cases were retrospectively evaluated. Two independent cardiologists measured intraoperative LAA ostial diameter and depth at standard 0°, 45°, 90°, and 135° TEE omniplane views and in the right anterior oblique (RAO) 30°, caudal (CAUD) 30° angiographic view. RESULTS: The average age and CHA2 DS2 VASc score were 74 (±7.2) years and 4.6 (±1.3), respectively. The average ostial diameter and depth (mm) by TEE were 0°: 19.6 and 26.5; 45°: 17.5 and 26.6; 90°: 18.3 and 25.1; 135°: 19.5 and 23.3. The ostial diameter and depth (mm) by RAO 30° CAUD 30° angiography were 21.1 and 29.7. This angiographic view corresponds to a TEE view between 90° and 135°. In comparison to angiography, TEE 90° underestimated the LAA ostial diameter by 2.9 ± 3.7 mm (P < 0.001) and by 1.9 ± 4.0 mm at TEE 135° (P < 0.01); Pearson's r 0.53 angiography/TEE 90° and 0.50 angiography/TEE 135°. More importantly, TEE 90° underestimated the true usable LAA depth by 5.4 ± 5.8 mm (P < 0.001) and by 7.3 ± 6.1 mm at TEE 135° (P < 0.001); Pearson's r 0.39 angiography/TEE 90° and 0.30 angiography/TEE 135°. CONCLUSIONS: Compared to TEE, LAA angiography provides additional depth information and may be particularly valuable when patients have insufficient depth for Watchman by TEE measures.


Assuntos
Apêndice Atrial/diagnóstico por imagem , Fibrilação Atrial/terapia , Cateterismo Cardíaco/instrumentação , Angiografia Coronária , Ecocardiografia Transesofagiana , Idoso , Idoso de 80 Anos ou mais , Apêndice Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Função do Átrio Esquerdo , Cateterismo Cardíaco/efeitos adversos , Feminino , Humanos , Masculino , Valor Preditivo dos Testes , Estudos Retrospectivos , Resultado do Tratamento
7.
Catheter Cardiovasc Interv ; 94(1): 165-170, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30588751

RESUMO

OBJECTIVES: This study investigates the correlation of occlusive wedge pressure (WP) with direct left atrial (LA) pressure in patients with severe mitral regurgitation (MR) undergoing transcatheter mitral valve repair (TMVr) with MitraClip. BACKGROUND: There is interest in acquiring objective hemodynamic parameters for intraprocedural guidance in patients undergoing MitraClip. METHODS: The study included 94 patients with severe MR at prohibitive surgical risk who underwent MitraClip at the University of California Davis Medical Center between 2014 and 2016. RESULTS: An average of 1.8 ± 0.7 clips were used to achieve MR grade of 2+ or less in 99% of patients. Correlation analysis of all (n = 236) pre-clip, inter-clip, and final-clip WP and LA pressures yielded a Pearson's R (r) of 0.85 and 0.79 for mean WP vs mean LA and WP V vs LA V, respectively. Median LA V to mean LA ratio (LAV:mLA) was 1.75 (IQR 1.5-1.9). 79% (n = 74) of patients had LAV:mLA ratio ≥ 1.5 with associated WP V vs LA V correlation (r) of 0.83. In patients with LAV:mLA ratio < 1.5, the correlation (r) was 0.69. Baseline characteristics were not significantly different between patients with LAV:mLA ratio ≥ 1.5 and patients with LAV:mLA ratio < 1.5. Post-procedure, median LA V: mean LA ratio decreased from 1.75 to 1.4, P = 0.0001. CONCLUSIONS: Correlation between WP and direct LA pressure in patients with severe MR undergoing Mitraclip is modest. Caution is advised when using WP to approximate LA pressure intraprocedurally, especially in patients with baseline low LAV:mLA ratios.


Assuntos
Função do Átrio Esquerdo , Pressão Atrial , Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/cirurgia , Monitorização Intraoperatória , Pressão Propulsora Pulmonar , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Feminino , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/instrumentação , Humanos , Masculino , Valva Mitral/diagnóstico por imagem , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/fisiopatologia , Desenho de Prótese , Sistema de Registros , Estudos Retrospectivos , Índice de Gravidade de Doença , Fatores de Tempo , Resultado do Tratamento
8.
J Electrocardiol ; 56: 70-76, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31325620

RESUMO

BACKGROUND: QT interval measured in the electrocardiogram (ECG) varies with RR interval challenging the calculation of corrected QT (QTc) in Atrial fibrillation (AF). OBJECTIVES: To identify the ideal Lead, number of complexes and the formula to measure QTc that correlates best between AF and sinus rhythm (SR). PROCEDURE: We identified ECGs from patients with AF before and after conversion to SR. After excluding patients on drugs and clinical conditions that prolong QT interval, QTc was calculated from all the leads using the formulae: Bazett (BF), Fridericia (FF), Framingham(FrF), Hodges (HF), Saige (SF) and Rautaharju (RF) during AF and SR. After identifying the lead with best linear correlation, we calculated QTc following the longest RR, multiple QRS complexes and average automated RR interval during AF and compared to SR. FINDINGS: In 52 patients (male 69%, age 63 ±â€¯9 yrs), QTc measured from Lead II correlated best with SR in majority of the formulae. QTc was consistently shorter with linear formulae. While BF overestimated QTc, FF was optimal comparing AF vs SR (416 ±â€¯33 vs 411 ±â€¯38 ms, ns) calculated from single, multiple or average automated RR interval. Bland Altman analysis of the average automated QTc versus the delta of individual automated QTcs shows the least variation in the QTc calculated by FF. CONCLUSIONS: BF in commercial software is not ideal for measurement of QTc in AF, Fridericia Formula in lead II from the average RR from automated ECG measurement maybe utilized for the calculation of QTc.


Assuntos
Fibrilação Atrial , Idoso , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Software
9.
Catheter Cardiovasc Interv ; 92(4): 792-796, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-30019833

RESUMO

OBJECTIVES: The purpose of this study is to describe the initial clinical experience with a steerable transseptal needle (STSN) for left-sided structural heart procedures. BACKGROUND: Targeted transseptal (TS) puncture is required for many structural heart procedures, and the use of a steerable needle has not previously been described. METHODS: Consecutive patients undergoing structural heart interventions with targeted TS puncture under transesophageal echocardiographic (TEE) and fluoroscopic guidance were studied. The STSN was used in all patients with a standard commercial TS sheath. Deflection of the needle was performed "real time" to achieve localization of the TS puncture site. RESULTS: Twenty-seven patients underwent STSN puncture of the interatrial septum. In all cases, the needle could be deflected in vivo to achieve optimal tenting and localization of the puncture site without having to remove or reshape the needle. The needle was deflected to match a wide range of right atrial diameters (width 4.3 ± 0.9 cm and length 6.0 ± 0.9 cm in the 4-chamber view). In two patients with prior mitral valve surgery and a fibrotic septum, assisted crossing was achieved using the piercing stylet in one patient, and Bovie energy in the other. There were no procedural complications, and all patients had successful completion of the intended structural heart procedure. CONCLUSIONS: The STSN needle can be used to target the intended puncture location on the interatrial septum with real-time adjustable deflection without the need to remove and reshape the needle. In all cases crossing was successful and there were no complications.


Assuntos
Septo Interatrial , Cateterismo Cardíaco/instrumentação , Cardiopatias/terapia , Agulhas , Idoso , Idoso de 80 Anos ou mais , Septo Interatrial/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Ecocardiografia Tridimensional , Ecocardiografia Transesofagiana , Desenho de Equipamento , Estudos de Viabilidade , Feminino , Fluoroscopia , Cardiopatias/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Punções , Radiografia Intervencionista/métodos , Fatores de Tempo , Resultado do Tratamento
11.
Catheter Cardiovasc Interv ; 89(6): E200-E206, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27220107

RESUMO

OBJECTIVES: Our objectives were to assess for differences between standard and radiofrequency (RF) needle in procedural times, success, and spatial accuracy. BACKGROUND: Targeted transseptal (TS) puncture is essential for structural heart interventions. Spatial accuracy of standard versus RF needle has not been reported. METHODS: Consecutive patients undergoing structural heart interventions requiring TS puncture were studied retrospectively. A standard needle was alternated with a RF needle. Procedural success and times were recorded. Measurements based on intraprocedural transesophageal echocardiograms of the intended versus final TS crossing site were obtained. Pre-puncture and maximal tenting of the septum were also recorded. RESULTS: Twenty-five patients underwent standard needle and 27 RF TS access. All RF needle attempts to cross were successful without an assistance wire. Three standard needle patients required assisted crossing. After failed TS access, two patients had successful RF TS access. TS procedural times significantly favored the RF needle for time from septum to puncture (P = 0.02). Both standard and RF access yielded accurate crossing with no significant differences between the intended and actual crossing site. Maximal tenting was significantly less with the RF needle (P = 0.004). There were no major complications. CONCLUSIONS: In the hands of an experienced operator, there were no major clinically significant differences between the standard and RF needle approaches. However, procedural unassisted crossing success was higher with the RF needle approach as compared to standard needle. Procedural times and degree of septum tenting favored the RF over standard needle. Accuracy was similar with both approaches. RF was a successful strategy when standard needle failed. There were no major complications with either TS puncture strategy. © 2016 Wiley Periodicals, Inc.


Assuntos
Cateterismo Cardíaco/instrumentação , Ablação por Cateter/instrumentação , Septos Cardíacos , Agulhas , Idoso , Idoso de 80 Anos ou mais , Cateterismo Cardíaco/efeitos adversos , Ablação por Cateter/efeitos adversos , Ecocardiografia Transesofagiana , Desenho de Equipamento , Feminino , Septos Cardíacos/diagnóstico por imagem , Humanos , Masculino , Pessoa de Meia-Idade , Punções , Estudos Retrospectivos
13.
Echocardiography ; 31(8): E234-9, 2014 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-25041155

RESUMO

Few cases of diastolic mitral regurgitation (MR) and tricuspid regurgitation (TR) have been reported in the world literature. We report the case of a 63-year-old woman admitted for syncope, with a permanent pacemaker following complete heart block. Echocardiography revealed that the timing of the diastolic TR (and noted MR) coincided with the second phase of the pulmonic insufficiency (PI) jet. The respirometer revealed that the diastolic TR and the second phase of the PI are highly sensitive to respiration (attenuated with inspiration and exacerbated with expiration). The uniqueness of this case is the rare occurrence of the exacerbation of PI as the result of diastolic TR.


Assuntos
Bloqueio Atrioventricular/complicações , Bloqueio Atrioventricular/diagnóstico , Ecocardiografia/métodos , Insuficiência da Valva Pulmonar/diagnóstico por imagem , Insuficiência da Valva Pulmonar/etiologia , Insuficiência da Valva Tricúspide/complicações , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Idoso , Diagnóstico Diferencial , Feminino , Humanos
14.
J Crohns Colitis ; 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38597690

RESUMO

BACKGROUND AND AIMS: Modifiable risk factors in Inflammatory Bowel Disease (IBD), such as physical activity, may be utilised as prevention strategies. However, the findings of previous studies on the association between physical activity and IBD risk have been inconsistent. We aimed to perform a systematic review and meta-analysis to estimate the effect of physical activity on IBD risk. METHODS: A search was conducted for relevant studies published before April 2023 that assessed the effect of pre-IBD diagnosis levels of physical activity on IBD incidence. Individual summary statistics (relative risks; RR), and confidence intervals (CI) were extracted with forest plots generated. We used the Grading of Recommendations Assessment, Development and Evaluation (GRADE) approach to assess the quality of evidence. RESULTS: 10 observational studies were included. For cohort studies, there were 1,182 Crohn's disease (CD) and 2,361 ulcerative colitis (UC) patients, with 860,992 participants without IBD. For case-control studies, there were 781 CD to 2,636 controls, and 1,127 UC to 3,752 controls. Compared to individuals with low physical activity levels, the RRs of CD in individuals with high physical activity levels for cohort and case-control studies were 0.78 (95% CI 0.68-0.88, P = 0.0001) and 0.87 (95% CI 0.79-0.95, P = 0.003), respectively. For UC, the RRs were 0.62 (95% CI 0.43-0.88, P = 0.008) and 0.74 (95% CI 0.51-1.07, P = 0.11). CONCLUSION: This meta-analysis suggests that physical activity is inversely associated with the risk of developing IBD, more so in CD than in UC.

15.
Heart Rhythm O2 ; 5(4): 217-223, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38690142

RESUMO

Background: Pericardial effusion requiring percutaneous or surgical-based intervention remains an important complication of a leadless pacemaker implantation. Objective: The study sought to determine real-world prevalence, risk factors, and associated outcomes of pericardial effusion requiring intervention in leadless pacemaker implantations. Methods: The National Inpatient Sample and International Classification of Diseases-Tenth Revision codes were used to identify patients who underwent leadless pacemaker implantations during the years 2016 to 2020. The outcomes assessed in our study included prevalence of pericardial effusion requiring intervention, other procedural complications, and in-hospital outcomes. Predictors of pericardial effusion were also analyzed. Results: Pericardial effusion requiring intervention occurred in a total of 325 (1.1%) leadless pacemaker implantations. Patient-level characteristics that predicted development of a serious pericardial effusion included >75 years of age (odds ratio [OR] 1.38, 95% confidence interval [CI] 1.08-1.75), female sex (OR 2.03, 95% CI 1.62-2.55), coagulopathy (OR 1.50, 95% CI 1.12-1.99), chronic pulmonary disease (OR 1.36, 95% CI 1.07-1.74), chronic kidney disease (OR 1.53, 95% CI 1.22-1.94), and connective tissue disorders (OR 2.98, 95% CI 2.02-4.39). Pericardial effusion requiring intervention was independently associated with mortality (OR 5.66, 95% CI 4.24-7.56), prolonged length of stay (OR 1.36, 95% CI 1.07-1.73), and increased cost of hospitalization (OR 2.49, 95% CI 1.92-3.21) after leadless pacemaker implantation. Conclusion: In a large, contemporary, real-world cohort of leadless pacemaker implantations in the United States, the prevalence of pericardial effusion requiring intervention was 1.1%. Certain important patient-level characteristics predicted development of a significant pericardial effusion, and such effusions were associated with adverse outcomes after leadless pacemaker implantations.

16.
Heart Rhythm ; 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38574789

RESUMO

BACKGROUND: Leadless pacemakers have emerged as a promising alternative to transvenous pacemakers in patients with kidney disease. However, studies investigating leadless pacemaker outcomes and complications based on kidney dysfunction are limited. OBJECTIVE: The objective of this study was to evaluate the association of chronic kidney disease (CKD) and end-stage renal disease (ESRD) with inpatient complications and outcomes of leadless pacemaker implantations. METHODS: National Inpatient Sample and International Classification of Diseases, Tenth Revision codes were used to identify patients with CKD and ESRD who underwent leadless pacemaker implantations in the United States from 2016 to 2020. Study end points assessed included inpatient complications, outcomes, and resource utilization of leadless pacemaker implantations. RESULTS: A total of 29,005 leadless pacemaker placements were identified. Patients with CKD (n = 5245 [18.1%]) and ESRD (n = 3790 [13.1%]) were younger than patients without CKD and had higher prevalence of important comorbidities. In crude analysis, ESRD was associated with higher prevalence of major complications, peripheral vascular complications, and inpatient mortality. After multivariable adjustment, CKD and ESRD were associated with inpatient mortality (CKD: adjusted odds ratio [aOR], 1.62 [95% CI, 1.40-1.86]; ESRD: aOR, 1.38 [95% CI, 1.18-1.63]) and prolonged length of stay (CKD: aOR, 1.55 [95% CI, 1.46-1.66]; ESRD: aOR, 1.81 [95% CI 1.67-1.96]). ESRD was also associated with higher hospitalization costs (aOR, 1.63; 95% CI, 1.50-1.77) and major complications (aOR, 1.33; 95% CI, 1.13-1.57) after leadless pacemaker implantation. CONCLUSION: Approximately one-third of patients undergoing leadless pacemaker implantation had CKD or ESRD. CKD and ESRD were associated with greater length and cost of stay and inpatient mortality.

17.
Heart Rhythm O2 ; 4(1): 18-23, 2023 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-36713041

RESUMO

Background: Fluoroscopy is the standard tool for transvenous implantation of traditional and leadless pacemakers (LPs). LPs are used to avoid complications of conventional pacemakers, but there still is a 6.5% risk of major complications. Mid-right ventricular (RV) septal device implantation is suggested to decrease the risk, but helpful cardiac landmarks cannot be visualized under fluoroscopy. Transesophageal echocardiography (TEE) is an alternative intraprocedural imaging method. Objective: The purpose of this study was to explore the spatial relationship of the LP to cardiac landmarks via TEE and their correlations with electrocardiographic (ECG) parameters, and to outline an intraprocedural method to confirm mid-RV nonapical lead positioning. Methods: Fifty-six patients undergoing implantation of LP with TEE guidance were enrolled in the study. Device position was evaluated by fluoroscopy, ECG, and TEE. Distances between the device and cardiac landmarks were measured by TEE and analyzed with ECG parameters with and without RV pacing. Results: Mid-RV septal positioning was achieved in all patients. TEE transgastric view (0°-40°/90°-130°) was the optimal view for visualizing device position. Mean tricuspid valve-LP distance was 4.9 ± 0.9 cm, mean pulmonary valve-LP distance was 4.2 ± 1 cm, and calculated RV apex-LP distance was 2.9 ± 1 cm. Mean LP paced QRS width was 160.8 ± 28 ms and increased from 117.2 ± 34 ms at baseline. LP RV pacing resulted in left bundle branch block pattern on ECG and 37.8% QRS widening by 43.5 ± 29 ms. Conclusion: TEE may guide LP implantation in the nonapical mid-RV position. Further studies are required to establish whether this technique reduces implant complications compared with conventional fluoroscopy.

18.
Cardiol Plus ; 8(2): 82-102, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37486153

RESUMO

The primary site of infection in COVID-19 exhibit is the respiratory system, but multiple organ systems could be affected. The virus could directly invade cardiomyocytes. Alternatively, cytokine storm could lead to myocardial injury. More importantly, the management of existing cardiovascular diseases must be re-examined in COVID-19 due to, for example, interaction between antiviral agents and with a wide variety of pharmacological agents. The Branch of Cardiovascular Physicians of Chinese Medical Doctor Association organized a panel of experts in cardiovascular and related fields to discuss this important issue, and formulated the "2023 Chinese Expert Consensus on the Impact of COVID-19 on the Management of Cardiovascular Diseases." The Consensus was drafted on the basis of systematic review of existing evidence and diagnosis and treatment experience, and covers three major aspects: myocardial injury caused by COVID-10 and COVID-19 vaccine, the impact of COVID-19 on patients with cardiovascular disease, and the impact of COVID-19 on the cardiovascular system of healthy people, and rehabilitation guidance recommendations. The Consensus involves 11 core clinical issues, including incidence, pathogenesis, clinical manifestations, treatment strategies, prognosis, and rehabilitation. It is our hope that this Consensus will provide a practical guidance to cardiologists in the management of cardiovascular diseases in the new era of COVID-19 pandemic.

19.
Beijing Da Xue Xue Bao Yi Xue Ban ; 44(5): 694-700, 2012 Oct 18.
Artigo em Zh | MEDLINE | ID: mdl-23073577

RESUMO

Left ventricular ejection fraction (LVEF) is the most important measurement of the left ventricular function and the most commonly used parameter in clinical cardiac imaging. LVEF can be measured with different cardiac imaging techniques: left ventricular contrast angiography by catheterization, echocardiography, radionuclide ventriculography, cardiac magnetic resonance imaging and cardiac computed tomography. In this article, we reviewed the specifics of each of the cardiac imaging modality, their strength and pitfalls. We also compared the consistency and variance between them. The selection of a specific cardiac imaging modality in clinical practice should depend on the indications, local expertise and the historic data of the patient. In general, these cardiac imaging modalities correlate well, but the variance and standard deviation are large so the measurement numbers should not be used interchangeably.


Assuntos
Ecocardiografia , Ventriculografia com Radionuclídeos , Tomografia Computadorizada por Raios X , Função Ventricular Esquerda/fisiologia , Ecocardiografia/métodos , Humanos , Imageamento por Ressonância Magnética
20.
J Cardiopulm Rehabil Prev ; 42(4): 258-265, 2022 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-35235540

RESUMO

PURPOSE: Atrial fibrillation (AF) is associated with the comorbidities of a sedentary lifestyle. Endurance athletes also show an increased incidence of AF. The role of exercise in the treatment of AF is unknown so this study aimed to examine the effects of supervised exercise on AF. METHODS: A meta-analysis of randomized controlled trials (RCTs) examining supervised exercise training in participants with AF was performed. The primary outcome was AF recurrence and burden. Secondary outcomes included AF symptoms, quality of life, and cardiorespiratory fitness (CRF). RESULTS: Thirteen RCTs, involving 1155 participants, were included. Paroxysmal AF was present in 34% and persistent AF in 64%. The types of exercise were diverse and included cardiac rehabilitation (64%), aerobic training (7%), Qi Gong (4%), interval training (11%), and yoga (15%). Exercise training reduced AF recurrence (relative risk = 0.77: 95% CI, 0.60-0.99), improved quality of life in 5 of the 10 components of the Short Form 36 survey, and improved CRF (standardized mean difference [SMD] = 0.56: 95% CI, 0.27-0.85). The AF burden was reduced only in studies that included continuous ambulatory monitoring (SMD =-0.49: 95% CI, -0.96 to -0.01) but not when all studies were included (SMD =-0.12: 95% CI, -0.61 to 0.38). There was no difference in adverse events between exercise and control. CONCLUSIONS: Supervised exercise training is safe, reduces AF recurrence, and improves quality of life and CRF in participants with AF. Further large RCTs with ambulatory monitoring and robust exercise regimens are needed to assess the effects of exercise training on AF burden and AF symptoms.


Assuntos
Fibrilação Atrial , Fibrilação Atrial/reabilitação , Exercício Físico , Tolerância ao Exercício , Humanos , Qualidade de Vida , Ensaios Clínicos Controlados Aleatórios como Assunto , Comportamento Sedentário
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA